Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC NO 18 BHARATHI STREET WEST GANDHI NAGAR AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | ₹1.7 Cr | L1 | Accepted-AOC L1Bidder |
| 2 | L2₹1.7 Cr+₹39,850 (0.23%)Rejected-Finance | ₹1.7 Cr+₹39,850 (0.23%) | L2 | Rejected-Finance Quoted rates higher than L1 |
| 3 | L3₹1.7 Cr+₹2.9 L (1.70%)Rejected-Finance | ₹1.7 Cr+₹2.9 L (1.70%) | L3 | Rejected-Finance Quoted rates higher than L1 |
| 4 | L4₹2.1 Cr+₹40.2 L (23.7%)Rejected-Finance | ₹2.1 Cr+₹40.2 L (23.7%) | L4 | Rejected-Finance Quoted rates higher than L1 |
| 5 | L5₹2.1 Cr+₹40.6 L (23.9%)Rejected-Finance | ₹2.1 Cr+₹40.6 L (23.9%) | L5 | Rejected-Finance Quoted rates higher than L1 |
Tender Value
₹1.9 Cr
EMD Value
₹2.6 L
Closing Date
5 Nov 2022, 6:00 pmClosed
CWE AF TRIVANDRUM
CWE AF TRIVANDRUM HQ SAC IAF COMPLEX AKKULAM THURUVIKKAL POST TRIVANDRUM 11
Provn of Infrastructure for commercial power supply for MPR site at AF Stn Thanjavur
2022_MES_552790_1
CWE(AF)/TVM/82425 E8 Provn of Infra Str for MPR
Open Tender
Civil Works
Lump-sum
450 days
Thanjavur
Class B category a(i)
6 documents required · 6 mandatory
₹1,000
GE AF Thanjavur
₹2.6 L
Yes
21 Nov 2022
19 Sept 2022
7 Nov 2022
19 Sept 2022
5 Nov 2022
22 Oct 2022
19 Sept 2022 - 3 Oct 2022
Amount
GENERAL SUMMARY (Note : Schedule 'A' Part I to VIII are prepriced by MES under Ser No. 2 to 9.Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only)
Total of Schedule ‘A’ Part I “BUILDING/STRUCTURES ”
Total of Schedule ‘A’ Part II “ SITE CLEARANCE/ EARTHWORK ”
Total of Schedule ‘A’ Part III “INTERNAL ELECTRIFICATION ”
Total of Schedule ‘A’ Part IV “ PATH/ CULVERT”
Total of Schedule ‘A’ Part V “ AREA DRAINAGE”
Total of Schedule ‘A’ Part VI “ LIGHTNING PROTECTION ”
Total of Schedule ‘A’ Part VII “AIR CONDITIONING ”
Total of Schedule ‘A’ Part VIII “EXTERNAL ELECTRIC SUPPLY ”
Sch 'A' Part- IX - MISCELLANEOUS ITEMS (Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only. Bidder shall insert their rate in Green field under column 6)
S&F Sheet metal enclouser for 8 way Distribution Board (DB's), double door, single pole and neutral with 200 amps rated bus bar, IP-43 protection suitable for fixing MCB'S/isolators after and including taking down old DB with MCB complete all as specified and as directed.
S&F Sheet metal enclouser for 4 way Distribution Board (DB's), double door, Triple pole and neutral with 200 amps rated bus bar, IP-43 protection suitable for fixing MCB'S/isolators after and including taking down old DB with MCB complete all as specified and as directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five starrated with brushless direct current motor (BLDC) complete all as specified and as directed.
Supply and fix exhaust fan steel body AC single phase 230 Volt of size 300mm sweep with blades and frame and lovers complete all as specified and as directed.
Supply and fix epoxy insulators suitable for fixing of copper strip 20 x 3mm including fixing accessories like screws plastic plugs etc.
Supply and fixing voltage stabilizer for automatic opertaion single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of + 2.5% and of capacity 4.0 KVA.
Supply and fix timer panel outdoor type digital 24 hour timer consisting of 65 amps tripple pole contactor and coil voltage 440 volts MCB TPN 63 amps including Auto/Manual fecility including fixing arrengment. (For 24 hr operation AC's) (for 02 Nos)
Supply and fixing power contactor tripple pole 60 amps AC - 3 rating 415 volts 50 HZ AC supply with auxilliary contact (1 NO + 1 NC) coil voltage 440 volts including drilling holes inside the timer panel. (For 24 hr operation AC's) (for 02 Nos)
Supply install testing and commissioning of energy efficient K-4 rated Isolation transformer 400 KVA 3 phase 400 volts 50 HZ oil cooled with first filling of transformer oil including PCC foundation and having salient features conductors sized to withstand the K-4 rated loads, rated temparature rise conforming to class - B, shilded for quality power, designed to operate at the rated temparature, engineered core and coil to manage the zero sequence flux caused by triplen harmonics, withstand 100% rated current without overheating the windings or saturating core, quit operation, conductors capable to carrying harmonic currents of non linear loads witghuot exceeding the temparature rating of insulation and comprising of following technical specifications:- K factor - K4 Input voltage - 433 volts Output voltage - 433 volts Freequency operation - 50Hz Phase impedence - 3-4% Input / Output confugration - Delta/Star or Zig Zag Windings - Copper Neutral conductor rating - 200% of rated load Temparature insulation class - Class H Temparature rise class - Class B HV test - 2500 Volt AC Enclose material and protection - IP 20, CRCA Mild steel Painting - RAL 7032/7035 or any other Operating temparatrure - 0 to 55 degree centigrade Humidity - up to 100% RH non condensing Standard - UL 156 I, IEEE - 657-110, IS - 11171
Supply, install, testing and commissioning Voltage stabilizer Servo controlled 400KVA for automatic operation three phase, naturally oil cooled, indoor type & designed for input variation between 240 Volts to 480 Volts with output voltage stabilized at 400 volts with accuracy +/- 1% and speed of correction 35 volts per second SVR, phase to phase and capacity 400 KVA with and including 1st filling of transformer oil including PCC foundation and having following specifications:- (i) Input voltage 240V - 480 V (ii) Output voltage stabilized - 400V +/- 1% (iii) Rated frequency 50 HZ (iv) No distoration in wave form (v) Response time not to exceed 10 mille seconds (vi) Efficiancy more than 98% (vii) Digital display voltmeter, Ammeter (viii) Capacity 400 KVA (ix) Operating temparature - 55 degree centigrade (x) Humidity 100% RH non condensing (xi) PROTECTIONS:- (i) Over load/short circuit protection (ii) High/low voltage cut off (iii) Bypass arrengement in case of emergency (iv) Single phase sequence change operation (v) Protection agaist Surges / Spikes (vi) Delay timer for restart
Supply install testing and commissiong on line UPS 3 phase of capacity 300 KVA including 2 volt VRLA battery 180 Nos 1250 AH including battery racks and suitable size of copper cables for interconnection of UPS and battery bank including PCC foundation complete having 30min back up, including following specifications :- (a) AC Input (Charger/converter) (i) Rated voltage - 400 Volt AX 3 phase 4 wire and ground (ii) Votage range +/- 20% (iii) Input power factor - 0.90 to 0.99 (iv) Input freequency - 50 Hz +/- 5% (v) Total harmonic distortion - less than 3% on 100% nonlenear load (b) Input (Bypass) (i) Configuration - 3 phase 4 wire (ii) Input voltage 400 volt AC +/- 20% (iii) Freequency - 50 Hz +/- 5% (iv) Over load on bypass static switch - 100% rated current rated continuous 10 times rated current for 20 milli seconds (v) No Break Transfer - UPS system shall have logic circuit to sense the following condition and transfer the load from module to bypass with out break (a) Inverter output under voltage / over voltage (b) Overload beyand the capacity of the inverter
(c) AC output (i) Rated voltage - 400 Volt AX 3 phase 4 wire and ground (ii) Voltage regulation +/- 1% (iii) Efficiency - not less than 95% (iv) Output freequency - 50 Hz (v) Total harmonic distortion - less than 1% for 100% linear load and less than 3% for 100% non linear load
(vi) Crest factor - 3:1 (vii) Overload AC mode - less than 110% for 60 Min, less than 125%, 10 Min, less than or equal to 150% 1 Min and greater than 150% by pass (viii) Overload battery mode - less than 110% for 10 Min, lessthan 125% for 1 Min, lessthan or equal to 150% 1 Sec and greater than 150% shutdown (d) Environment (i) Operating temparature - 0 to 50 degree centigrade (ii) Relative humidity -100% non condensing (iii) Audio able noise - less than 65 DB at a distance 1 Mtr from any side of the UPS system (iv) Protection class - IP30 (e) Mimic Display (i) Mains available (ii) Rectifier operative (iii) Invertor operation (iv) Battery voltage OK (v) Bypass supply Ok (vi) Load on bypass (vii) Load on inverter (viii) Fault code cte
(f) Alarms (i) Inverter OFF/failed (ii) Rectifier OFF/failed (iii) Emergency stop (iv) Over temparature (v) Over load (vi) By pass mode alarm (g) Protection (i) Overload (ii) Short circuit (iii) Input low voltage (iv) Battery over charging (v) Battery over discharging (vi) Over temparature (vii) Over and under voltage for both input and output (h) Metering - Multiflexed LCD display to read following parameters (i) Output voltage (ii) Output current (iii) Battery voltage (battery status) (iv) Battery charge / discharge (v) Input voltage, current and freequency (vi) Data log with date and time
Supply and install hi wall split units indoor/outdoor complete with cordless remote controle unit and with inbuilt air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.29 of capacity 1.5 TR.
Supply installation testing and commissioning ATS (automatic transfer switch) 4 pole (TPN) with enclosure with complete protection 630 amps 415 volts 50 HZ AC supply including mounting arrengement and including digital volt meter and ammeter with existing cable.
Supply and fixing inside the PVC junction box SMPS 24 volt 10 amps DC supply input voltage 230 volts 50 Hz AC Supply including NONC contactors 02 Nos and relay and reset push buttons etc (for alarm if failure and restoration of commercial supply)
Supply laying and testing PVC insulated and PVC sheathed cable galvonised steel strip or wire armoured electrical control cable (Heavy duty) with stranded copper conductor of size 3 core 4 sqmm 1100 volts grade. (for alarm if failure and restoration of commercial supply)
Supply and fix GI pipe bracket made out of medium grade 40mm bore GI tubing duly bend to the required shape, length of the bracket shall be not less than 1.5m including MS flat iron clamp , nuts, bolts and washers for fixing of brackets on pole complete all as specified and as directed.
M&L for Earthing complete with galvanised steel earth plate electorde 60x60 cm x 6 mm thick, buried directly in ground with earth pit not less than 2.25 metters deep below ground level with top edge of the plate not less than 1.5 meters below normal ground level connectred to galvanised 4.00mm dia earth lead connected by means of bolts, nuts, chek nuts and washers , earth wire protected by galvanised iron or steel all as shown in electric plate No.3 connected to earthing test point all as specified or indicated including testing on completion.
Earthing complete with copper earth plate electorde 60x60 cm x 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connectred to copper earth strip of size 20mmX3mm connected by means of bolts, nuts, chek nuts and washers of brass are shown in electric plate No.3connected to earthing test point all as specified or indicated including testing on completion.
Boring of holes under roads, pavements, hard standing by trench less technology using ultra sounding technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure.
Returning and filling in two parts (i) using riddled soil obtain from excavated soil upto depth of 30 cm (8 cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil all as specified and directed. Note:- Excavated soil shall be riddled by using sieve to separate composite partricles etc as per IS 1255 1983 and refilling in trenches as in cable cushioning.
N Rathinam
C R R CONSTRUCTIONS
B5BUILDING SOLUTIONS
Vinayaka Enterprises
RISHABH BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .