Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 LAccepted-AOC 3RD FLOOR KANAGAMANI TOWERS PLOT NO 6 200 FEET ROAD PONNIAMMANMEDU TIRUVALLUR TAMIL NADU 600110 | THIRUVALLUR | TAMIL NADU | 600110 | L1 | Accepted-AOC Accepted | |
| 2 | Rejected-Technical 7 FIRST FLOOR SIVA CO BUILDING KUBERAGANAPATH STREET PADI CHENNAI PADI CHENNAI THIRUVALLUR TAMIL NADU 600050 | CHENNAI | TAMIL NADU | 600050 | - | Rejected-Technical Rejected |
| Sl No | Description | Qty | Unit | VFL Sciences Private Limited L1 |
|---|---|---|---|---|
| 1.00Purchase of Equipment | ||||
| 1.01 | Bench Top Glass Insitu Airlift Photo Bioreactor
1. Vessel Capacity: 3 Liter Borosilicate Glass (working volume: Two to Three Liters maximum), Vessel HXD Ratio 4:1 (400x100mm)
2. Head Plate & Bottom Plate MOC: SS 316L
3. Ports in Top Plate: pH sensor; dissolved oxygen (DO) sensor; pressure sensor; air in and draft tube; air out; acid/base; sampling; and addition port.
4. Mixing Method: Ring sparger to create airlift circulation inside the reactor for uniform mixing and better aeration.
5. Holders for Sensor /Adapter / Blind Stoppers in Head Plate: pH sensor holder; Media double inlet for acid/base dosing; Air sparger - Ring type for airlift application without stirring, air out with exhaust filter and open/close valve; Pressure sensor holder; sampling pipe; Blind stopper for un used port; Unique suitable SS puncturing needles for sampling, air in, air out, inoculum, feed addition.
6. Ports in Bottom Plate with Stand: Port for Temperature sensor; Heating finger U-tube heat exchanger; Drain.
7. Holders for Sensor / Adapter / Blind Stoppers in Bottom Plate: Holder for temperature sensor, Heating finger, U-tube heat exchanger.
8. Sensors: Temperature, Gel filled sterilizable pH sensor, & Pressure sensor.
9. Controls and Display: Modular independent system of pH, temperature, pressure with touch screen graphical display & control; Two Set point control of pH with three-point buffer auto calibration; Aeration by flow meter 0-5lpm with air pump; Sterilization controls up to 121℃ without steam generator along with pressure safety mechanism by independent pressure sensor and digital display & control; Automatic digital pressure safety and over temperature safety cutoff and alarm; Upgradable control system for future prospective as CSTR reactor & dissolved oxygen (DO).
10. Measurement and Control Range: pH: 2-14; Process temperature: 20℃ to 60℃; Sterilization temperature: up to 121℃; and Pressure up to 15 psi.
11. Fixed Speed Peristaltic Pump: For acid/base dosing with Teflon non spring head. (2 Nos)
12. Cooling System: Chiller cum circulator. Chiller temperature range 4℃ to 40℃, bath capacity 5L to cool down the reactor after sterilization and to work process temperature below ambient condition.
13. Illumination System: Two illumination assembly with variable intensity control (1000-3000 lux) around the reactor with independent control switch for photobioreactor, or other application and easy detachable if not in use.
14. Essential Accessories : Silicon tubing for acid/base addition (10m); air in and sampling (10m); water circulation (5m); air vent filters 0.2 micron sterilizable (6Nos); and silicon septum (25Nos)
15. Starter Kit: Spare Silicon-O-rings for head plate, bottom plate (1No each), all other ports (5Nos each), Alen key.
16. Warranty: One year
17. Support (Must): Unconditional onsite technical support shall be provided as and when needed. The supplier must provide complete installation and hands-on demonstration of the equipment at the user site upon delivery.
18. The vendor should have a registered presence in India with an authorized local service provider in Tamil Nadu. | 1 | Nos | 9,47,540 ₹9,47,540 Lowest |
Tender Value
Refer Docs
EMD Value
₹18,960
Closing Date
9 Dec 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Registrar
Bharathiar University, Coimbatore
Equipment
2025_HE_626046_1
C7/CRTD/Biotech/DBT/1884
Open Tender
Electrical Goods/Equipments
Supply
Bharathiar University
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹18,960
Yes
10 Mar 2026
24 Nov 2025
10 Dec 2025
24 Nov 2025
9 Dec 2025
24 Nov 2025
Purchase of Equipment
Bench Top Glass Insitu Airlift Photo Bioreactor 1. Vessel Capacity: 3 Liter Borosilicate Glass (working volume: Two to Three Liters maximum), Vessel HXD Ratio 4:1 (400x100mm) 2. Head Plate & Bottom Plate MOC: SS 316L 3. Ports in Top Plate: pH sensor; dissolved oxygen (DO) sensor; pressure sensor; air in and draft tube; air out; acid/base; sampling; and addition port. 4. Mixing Method: Ring sparger to create airlift circulation inside the reactor for uniform mixing and better aeration. 5. Holders for Sensor /Adapter / Blind Stoppers in Head Plate: pH sensor holder; Media double inlet for acid/base dosing; Air sparger - Ring type for airlift application without stirring, air out with exhaust filter and open/close valve; Pressure sensor holder; sampling pipe; Blind stopper for un used port; Unique suitable SS puncturing needles for sampling, air in, air out, inoculum, feed addition. 6. Ports in Bottom Plate with Stand: Port for Temperature sensor; Heating finger U-tube heat exchanger; Drain. 7. Holders for Sensor / Adapter / Blind Stoppers in Bottom Plate: Holder for temperature sensor, Heating finger, U-tube heat exchanger. 8. Sensors: Temperature, Gel filled sterilizable pH sensor, & Pressure sensor. 9. Controls and Display: Modular independent system of pH, temperature, pressure with touch screen graphical display & control; Two Set point control of pH with three-point buffer auto calibration; Aeration by flow meter 0-5lpm with air pump; Sterilization controls up to 121℃ without steam generator along with pressure safety mechanism by independent pressure sensor and digital display & control; Automatic digital pressure safety and over temperature safety cutoff and alarm; Upgradable control system for future prospective as CSTR reactor & dissolved oxygen (DO). 10. Measurement and Control Range: pH: 2-14; Process temperature: 20℃ to 60℃; Sterilization temperature: up to 121℃; and Pressure up to 15 psi. 11. Fixed Speed Peristaltic Pump: For acid/base dosing with Teflon non spring head. (2 Nos) 12. Cooling System: Chiller cum circulator. Chiller temperature range 4℃ to 40℃, bath capacity 5L to cool down the reactor after sterilization and to work process temperature below ambient condition. 13. Illumination System: Two illumination assembly with variable intensity control (1000-3000 lux) around the reactor with independent control switch for photobioreactor, or other application and easy detachable if not in use. 14. Essential Accessories : Silicon tubing for acid/base addition (10m); air in and sampling (10m); water circulation (5m); air vent filters 0.2 micron sterilizable (6Nos); and silicon septum (25Nos) 15. Starter Kit: Spare Silicon-O-rings for head plate, bottom plate (1No each), all other ports (5Nos each), Alen key. 16. Warranty: One year 17. Support (Must): Unconditional onsite technical support shall be provided as and when needed. The supplier must provide complete installation and hands-on demonstration of the equipment at the user site upon delivery. 18. The vendor should have a registered presence in India with an authorized local service provider in Tamil Nadu.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.59 MB
BOQ_748607.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .