Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹90.3 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹98.6 L+₹8.3 L (9.23%)Rejected-AOC NO 49 MSN NILAYAM 3RD CROSS HILL VIEW GARDEN TUNAHALLI SUBRAMANYAPURA POST BANGALORE 560061 | BANGALORE | BANGALORE | KARNATAKA | 560061 | L2 | Rejected-AOC NOT BEING LOWEST | |
| 3 | L3₹1.1 Cr+₹16.4 L (18.1%)Rejected-AOC 20 1ST A CROSS SAI NAGAR AREHLLI UTTARHALLI BANGALORE 560 061 | BENGALURU URBAN | KARNATAKA | 560061 | L3 | Rejected-AOC NOT BEING LOWEST | |
| 4 | L4₹1.1 Cr+₹22.8 L (25.3%)Rejected-AOC NO 12 5TH B CROSS SHARADAMBA NAGAR M E S ROAD BANGALORE 560013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L4 | Rejected-AOC NOT BEING LOWEST |
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
10 Mar 2025, 6:00 pmClosed
COL MANOJ NEGI
CWE AF NORTH BANGALORE BELLARY ROAD JC NAGAR POST BANGALORE 560006
PROVN OF ALL WEATHER SHED, IMPROVEMENT TO MAIN GATE, AUGMENTATION OF WATER STORAGE FACILITY AND MODERNISATION OF WAREHOUSE STORAGE FACILITY AT VARIOUS LOCATIONS UNDER GE (AF) MARATHAHALLI
2025_MES_696471_1
87577CWEAFNMAR
Open Tender
Civil Works
Item Rate
270 days
GE (AF) MARATHAHALLI
AS PER NIT
7 documents required · 7 mandatory
₹1,000
GE (AF) MARATHAHALLI
₹1.7 L
Yes
3 Apr 2025
5 Feb 2025
12 Mar 2025
6 Feb 2025
10 Mar 2025
26 Feb 2025
6 Feb 2025 - 19 Feb 2025
Amount
M & L for excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / laying under ground electric cable including taking out old bricks from trenches and separating serviceable bricks and set aside for reuse complete all as specified and as directed.
M & L for returning, filling in, including spreading levelling watering and well rammming in layers not exceeding 25 cms in depth complete all as specified and as directed.
Supply, laying of riddled earth soil conformed to IS-1255, cushioning to cables with a layer of riddle earth soil 15cm deep before laying the cable and 8 cm depth after laying of cable, complete all as specified and directed.
M & L for brick protection cover on cable with sub class 'B' brick laid dry flat adjacent to each other complete all as specified and directed.
S & F of GI tubing, light grade, 32 mm bore with all fitting laid in trenches / pole / wall for protection of cables in repairs complete all as specified and directed. Make - TATA / ZINDAL / Bansal or equivalent.
M & L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
Supply and laying of cable XLPE insulated screened, PVC bedded, galvanised, steel strip or wire armoured, electric power cable, (heavy duty) 1100 volts grade, with stranded aluminium conductor of size 2 core x 10 Sqmm complete all as specified and directed.
S & F of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC surface/recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver, three core flexible copper conductor cases of suitable size complete all as specified and directed.
S & F of LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
S & F MCB SP 6-32 Amps, 10 KA breaking capcity, 'C' series, 240 V complete incl making conections all as specified and directed.
M & L for sub main wiring complete with two runs of 2.5 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories in surface of wall, roofs etc with one run of PVC insulated copper conductor 1x 2.5 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC casing capping and two run of copper conductor together taken as one length for measuring unit length.
S & F MCB SPN 32 Amps, 10 KA breaking capcity, 'C' series, 240 V complete incl making conections all as specified and directed.
S & F MCB DB SPN 8 Way with 200 Amps rated busbar, Double door, 240 volts flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing complete all as specified and directed.
M & L for excavating in trenches in Hard/dense soil not exc 1.5 meter wide and not exc 1.5 meter depth for foundation etc and getting out complete all as specified and directed.
M & L for removing excavated material exc. 250 m but n exc 500 m and depositing where directed .
M & L for RCC 1:2:4 type B-1, using 20 mm graded stone aggregate as in column footing including raft footings, foundation, plinth beam, bases of columns etc. complete all as specified and directed.
M & L for use and waste of form work to sides of concrete foundation, footing, bases of columns, plinth beam, side and soffits of plinth beam and similar works in vertical surfaces complete all as specified and directed.
S & F of TMT bars 10 mm dia and over, cut to length, bent to shape as required incl cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia, complete all as specified and as directed
All as per item No 19 above but for 5mm dia and over upto and including 10mm dia as in stirrups, spaces and binders etc.
Demolition of reinforced Cement concrete of gate piller, column , slab, beam or any description and in any position not otherwise specifically provided for complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S & F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, ornamental and intricate designs fabrication etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges, or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening complete all as specified and directed.
Demolition of brick work built in cement mortor or lime motor complete all as specified and directed.
M & L for 1:3:6 type C1 with 20mm graded aggegate pre-cast cement concrete block masonry with solid blocks, exc.10cm in width and setting in mortar 1:6 complete all as specified and directed.
M & L for plastering 15 mm thick in Cement Mortar 1:4 on fair faces of Brick Wall, Cement block wall or on Concrete Surfaces, finished even and smooth without using Extra Cement complete all as specified and as directed.
M & L for preparation of new plastered wall surfaces and applying two coat of cement based paint on walls over a coat of primer with alkali resistant priming paint complete all as specified and directed.
M & L Complete removal of old plastered wall surfaces and applying two coat of cement based paint on walls over a coat of primer with alkali resistant priming paint complete all as specified and directed.
M & L for Granite (of any type) work (table rubbed and polished) in steps, jambs, concrete pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 10 mm thick rendering in CM 1:3 to receive grainite slab including rounding and grinding of edges and corners etc complete all as specified and directed.
S & F compound girders and stanchions, lattice girders, vertical piers, framed posts, shed pillers, aerial masts, staging for water tanks and the like including caps, bases, splices etc. buillt up from two or more beam or channel sections.
M & L steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St.-240 complete all as specified and directed.
M & L Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting accessories.
S & F Plates (plain or chequered) channels , square or beams cut or notched (ordinary and counter sunk) forming holes, without any attachments or with riveted, bolted or welded attachments, etc conforming to Fe 410-W (Gde-E-250) quality-A complete all as specified and directed. Note - cutting to require size and welding or boulting to Beam, post, rafter shall be at site, rate included in this item.
S & F Pre-painted galvalum aluminium zinc coating GI based corrugated steel sheet 0.50mm thick (total coated thickness) of any colour having tensile strength of 550 Mpa minimum, yeild strength as in roof covering/clading to wall, fixing, it shall be coated with hot dip alloy of 55% aluminimum, 43.5% zinc, 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/ sqm of coating as specified and shall be fixed with hot dip galvanised, self drilling and self tapping screws neoprene and EDPM washers as in roof covering all as specified and dircted.
S & F Pre-painted galvalum aluminium zinc coating GI based plain steel sheet 0.50mm thick (total coated thickness) of any colour having tensile strength of 550 Mpa minimum, yeild strength as in roof covering/clading to wall, fixing, it shall be coated with hot dip alloy of 55% aluminium, 43.5% zinc, 1.5% silicon and finished with resin coat on both surface @ 150 gm/ sqm of coating as specified and shall be fixed with hot dip galvanised, self drilling and self tapping screws neoprened and EDPM washers as in roof covering all as specified and dircted.
M & L for preparation of new steel surfaces of any description over 10cm width or girth and painting with two coats of synthetic enamel paint over a coat of red oxide primer completed all as specified and directed.
M & L Mild steel bolts exc 20 mm and n exc 25 mm dia purpose made with hexagonal or square head one end and screwed the other or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long complete all as specified and directed.
S & F 150 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints and fixed to wall complete all as specified and directed
S & F 150 mm dia PVC (SWR) bends of any radius with access door complete all as specified and directed
S & F 150 mm dia PVC (SWR) junction single T equal or un equal complete all as specified and directed
M & L 5 mm thick ACP sheet fixed over aluminium rectangular tube section of size 50 mm 25 mm x 2.0 mm thick with self taping screws, aluminium frame work shall be fixed on MS Tube post as in square/rectangular/circular shape, corners / joints should be filled with appropriate material to match the surface complete all as specified and directed.
S & F Stanless steel letters grade 304 not less than 1 mm thick of approved pattern of height 250 mm, width in proportion to height as per requirement of the letter and depth of letter 25 mm including necessary fixing as per manufacturer instruction, polishing, complete all as specified and directed.
S & F 1.25 mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed.
S & F 6 to 8 mm thick weather proof PVC interlocking false ceiling/cladding of approved colour and texture including GI grid frame work fixing to roof truss, height up to 8 mtr specification all as per manufacture instructions compete all as specified and directed. Note : Rate includes scaffolding or staging and all required fixing arrangements etc.
S & F chemical dehumidifier continous operating complete for 100 Cfm capacity :- (i) dehumidifying capacity - 1.56 kg/hr (ii) process air flow - 200m3/hr (iii) reactivation air flow - 100m3/hr (iv) applied temperature - - 50C to 500C (v) max power - 2.0 KW (vi) power rating - 2.1 KW (vii) voltage - 220 / 50 Hz (viii) current - 8.5 Amps (ix) dimension - 300 x 100 x 450 mm (x) weight - 50 Kg (xi) quality / safety approval - ISO/CE.Rohs
S & F chemical dehumidifier continous operating complete for 206 Cfm capacity :- (i) dehumidifying capacity - 1.96 kg/hr (ii) process air flow - 350m3/hr (iii) reactivation air flow - 150m3/hr (iv) applied temperature - - 50C to 500C (v) max power - 2.5 KW (vi) power rating - 2.6 KW (vii) voltage - 220 / 50 Hz (viii) current - 9.5 Amps (ix) dimension - 500 x 300 x 850 mm (x) weight - 75 Kg (xi) quality / safety approval - ISO/CE.Rohs
S & F chemical dehumidifier continous operating complete for 382 Cfm capacity :- (i) dehumidifying capacity - 3.5 kg/hr (ii) process air flow - 650m3/hr (iii) reactivation air flow - 350m3/hr (iv) applied temperature - - 50C to 550C (v) max power - 6.7 KW (vi) power rating - 7.5 KW (vii) voltage - 415V / 50 Hz (viii) current - 9.5 Amps (ix) dimension - 700 x 500 x 1050 mm (x) weight - 140 Kg (xi) quality / safety approval - ISO/CE.Rohs
S & F single pole and neutral enclosure with two pin and earth plug and socket including 1 No. Double pole MCB 20 Amp capacity complete all as specified and as directed
S & F Triple pole and neutral enclosure with Three pin and earth plug and socket including 1 No. Triple pole MCB 32 Amp capacity complete all as specified and as directed
M & L for sub main wiring complete with four runs of 6 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 6 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC casing capping and two run of copper conductor together taken as one length for measuring unit length.
M & L for sub main wiring complete with four runs of 10 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 10 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC casing capping and two run of copper conductor together taken as one length for measuring unit length.
M & L for sub main wiring complete with two runs of 4 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 4 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC casing capping and two run of copper conductor together taken as one length for measuring unit length.
S & F MCB TPN 63 Amps 10 KA breaking capcity, 'C' Series, 240 V incl making connections all as specified and directed.
S & F MCB DB TPN 4Way, Double Door flush to wall including all cutting etc on wall including making good the disturbed surfaces to match the existing complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate electrode of size 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI earth lead wire 4.0 mm dia by means of galvanized bolts, nuts, washers and brazed properly with connected to earth test point & to main switch board, LT panel etc with & including adequate quantity of charcoal dust and common salt around earth plate, PCC 1:3:6 type C-1 using 20mm graded stone aggregate for earth pit with pre cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia MS round bar handle, GI light grade watering pipe 20 mm dia with funnel and wire mesh, and 40 mm dia GI light grade earth lead protection pipe, complete all as specified & directed. Note- The unit rate includes main earthing lead GI earth wire 4.0 mm dia with 40 mm dia GI light grade earth lead protection pipe from earth electrode to test point up to 7.5 mtr.
M & L for Post construction Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2(1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed.
M & L for Post construction treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for all as specified and as directed.
M & L for excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out in hard/dense soil complete all as specified and directed.
M & L for concrete 1:2:4 type B-2 (using 40 mm graded stone aggregate) in foundation, filling and mass concrete all as specified and directed.
S & F for roof trusses/rafters/purlins and fastenings and heavy bracket framing (beams, tee, angle, channel or falt sections) including distance pileces decks etc complete all as specified and directed.
S & F Mild steel bolts diameter of neck exc 12 and n.exc 20mm purpose made. with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long complete all as specified and directed.
M & L for 25mm thick Cement concrete type B1 1:2:4 (20mm graded aggregate) in floor complete all as specified and directed.
M & L for 75mm thick Cement concrete type B1, 1:2:4 (20mm graded aggregate) in floor, finished even and smooth without using extra cement including spike rolling to surfaces or making impressions of expanded metal whilst the concrete is green complete all as specified and directed.
M & L Machine cut kota stone slab flooring 20-25mm thick, over cement screed base laid , set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 1:4 , 20mm thick including rubbing and polishing of stone slab all as specified and as directed
M & L joint free coloured non skid ceramic tiles 7 to 8mm thick, area of each tile exc 0.18 sqm but n.exc 0.38 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 1:4 15mm thick all as specified and as directed
M & L for PCC 75 mm thick 1:3:6 type C2, (40 mm graded aggregate) as in plinth protection, finished even and smooth with using extra cement. incl. joints of the plinth protection should be filled with sand and bitumen mortar (1:2) and sealed with bitumen grading complete all as specified and directed
M & L for Removing excavated material to out side MoD Land as per state/local body guidelines.
M & L for removing building materials (Earthwork etc) to out side of MoD Land as per state/local body/Municipalities guidelines.
M & L for earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth,1.5 m in width as well as 10sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m all as specified and directed.
All as iteme no 69 above but for exc 1.50m and n. exc 3.0 m in depth.
M & L for RCC (design mix), M 30 (20 mm graded aggregates) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete all as specified and directed.
M & L for formwork to sides of pillars, posts, struts, piers, columns, and stanchions concrete all as specified and directed.
M & L for RCC, M 30 (design mix) with 20 mm graded aggregates as in Columns, pillars, piers, posts and struts concrete all as specified and directed.
M & L for formwork to faces of walls, retaining walls, abutments, parapets and staircase railing and similar work including attached pillasters, buttresses, etc.; vertical or to batter all as specified and directed.
M & L for RCC, M 30 (design mix) with 20 mm graded aggregates as in walls, retaining walls, basement walls and the like; any thickness; above top of footings; including attached pilasters and buttresses all as specified and directed.
M & L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. all as specified and directed.
M & L for RCC M 30 (design mix) with 20 mm graded aggregates as in beams, cantilevers, bressummers, lintels over 1.5m span, all as specified and directed.
M & L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) all as specified and directed.
M & L for RCC, M 30 (design mix) with 20 mm graded aggregates as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and directed.
M & L for providing precast cement concrete type B1 1:2:4 (20 mm graded aggregate) in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles set in CM1:4 with plain faces concrete all as specified and directed.
M & L for rendering 10mm thick in ceilings on fair faces of brick work or concrete surfaces in CM 1:3, finished even and smooth without using extra cement concrete all as specified and directed.
M & L for rendering 20 mm thick on fair faces of brick work or concrete surfaces in CM 1:3 with WPC, finished even and smooth without using extra cement, all as specified and directed. Note : WPC shall meassured and paid separately.
M & L for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:4, finished even and smooth without using extra cement all as specified and directed.
M & L for 40mm thick PCC (1:2:4) type B0 using 12.5 mm graded stone aggregate as in floors and pavings haunching on all sides with WPC, complete all as specified and directed. Note : WPC shall meassured and paid separately.
Supply only integral water proofing compound all as specified and directed.
M & L for framed work such as in aluminium ladder complete all as specified and directed.
M & L for PVC water bar of size 225 x 8mm inserted in position all as specified and directed.
M & L for G.I. tubing light grade of size 50mm bore for protection of cables to be laid under roads, crossings/culverts complete all as specified and directed.
S & F 10 HP (or 7 WHP) Submerssible pump electric driven 415 3 phase volts Horizontal type suction and delivery 100x80mm complete including bedding fixing and pcc work, connection motor to starter, panel testing and commissioning complete all as specified and directed.
S & F 5 HP (or 3 WHP) Submerssible pump electric driven 415 3 phase volts Horizontal type suction and delivery 100x80mm complete including bedding fixing and pcc work connection motor to starter, panel testing and commissioning complete all as specified and directed.
S & F submersible pump automatic star delta starter panel with voltmeter, Ammeter, indicator, Rotary Switch 10HP motor 3 phase 50Hz AC complete all as specified and directed.
S & F 3 core, 6.0 sqmm copper flat cable for submersible pump complete all as specified and directed.
S & F 3 core, 4.0 sqmm copper flat cable for submersible pump complete all as specified and directed.
S & F GI pipe medium grade ISI marked including GI fitting such as bend, tee, union, collar, reduser, elbow etc laying in trenches or fixed in walls/ceilings/floor of 80 mm dia bore pipe
All as per item No 95 above but for 100 mm dia bore pipe
All as per item No 95 above but for 50 mm dia bore pipe
All as per item No 95 above but for 40 mm dia bore pipe
S & F of gunmetal gate valve of size 40 mm dia with screwed head wheel complete all as specified and directed.
S & F flanged Non return valve 80 mm flap type, cast iron body, PN1.0, confirming with IS provision of 3mm thick rubber gasket on both sides of the flanges, bolts and nuts complete all as specified and directed.
S & F sluice valve 80 mm dia with stainless steel spindle and iron wheel head long body class PN 1.0 complete with rubber gaskets, nuts, bolts of suitable size, ISI marked complete all as specified and directed.
S & F sluice valve 100mm dia with stainless steel spindle and iron wheel head long body class PN 1.0 complete with rubber gaskets, nuts, bolts of suitable size, ISI marked complete all as specified and directed.
M & L for cutting cast iron/DI pipes of size 150 mm dia and reducing to required length before laying pipes in trenches of different sizes as per site requirement, complete all as specified and directed.
All as per item No. 103 above but of size 150 mm dia in position for inertion of new tees, branches as per site requirement etc complete all as specified and directed.
M & L for laying of DI pipe 100 mm dia class K-9 with socket and spigot ends centrifugally cast (spun) with cement mortar lining inside the pipe and zinc coated outside with black or blue epoxy coating as per IS 8329/2000 in available lengths suitable for push on tyton joints (rubber gasket jointing), collar etc as required on the site laid in trenches complete all as specified and as directed.
M & L for rubber tyton joints suitable for 100 mm dia DI pipes complete all as specified and directed.
M & L for lead joints including caulking for CI/DI pipe of size 150 mm dia complete all as specified and directed.
M & L for DI specials such as bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc) tee pieces single branch, "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs upto 150 mm dia complete all as specified and directed.
M & L for precast cement concrete 1:3:6 type C2 using 40mm graded stone aggregates as in mass concrete/foundation/for supporting (encasing) of DI pipe specials of any size and in any position including plastering of surfaces complete all as specified and directed
M & L for precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregates as in mass concrete/foundation/for supporting (encasing) of DI pipe specials of any size and in any position including plastering of surfaces complete all as specified and directed
M & L for cement rendering for pipe support pillar outside of cement mortar 1:6 and 10mm thick complete all as specified and directed.
M & L for construction of valve chamber of size 1200x1200x1000mm with foundation cement concrete brick/bricks in cement mortar 1:6, with PCC 1:4:8 type D2 sub base plaster internally and exposed external surface in cement mortar 1:4 15mm thick and provision of valve chamber cover made out of MS sheet 3.0mm thick welded on angle iron frames 40x40x5mm made out of double door type with hinges and locking arrangement duly painted with 2 coat of synthetic enamel paint over a coat of red oxide primer all as specified and directed complete with good finishing.
Supply, laying and testing of cable XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed.
S & F delivery pipe pressure gauge analog type of capacity 0 to 10.60 Kg/sqcm (0 to 150 lb/Sq inch) of dial size 100 mm dia all as specified and as directed.
Supply and errection of CPRI approved LT cubical outdoor type enclosure (Box type) made out of CRCA sheet 3.0 mm thick totally enclosed with front opening, with projected and raised platform of suitable size for fixing all accessories, weather proof with locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of switch gear about load termination, and the nuts/bolts, three phase with neutral bus bar 200 amps with ISI standard sleeves etc, are to be made of rust proof material and as per IS: 8623 with necessary arrangement including pcc foundation 1:2:4, 20 mm stone aggregate, for three phase and capacity complete & powder coating painting and necessary internal electric connection as required and provision of the following items :- (a) MCCB 63 Amp 4 Pole 50 Hz 415 V with rupturing cap 25 KA.-01 No (incoming) (b) MCB TPN 40 Amp-02 No for pump sets c) MCB SPN 32 Amp-02 Nos (d) Submersible pump starter 5HP capacity DOL-02 Nos (e) VAF-PF-meter C1 (f) Indicating lamps RYB-01 set
PRAGATHI BUILDERS (BID ID -3258851)
K. VENKATESH NAIDU (BID ID -3259447)
Shanthi Construction (BID ID -3258782)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .