Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.8 L+₹2.1 L (11.0%)Rejected-Finance 13 218 MASJID EXTEN SADAR BAZAR | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹23.7 L+₹4.9 L (26.4%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹24.5 L+₹5.8 L (30.8%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹26.1 L+₹7.4 L (39.3%)Rejected-Finance 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
16 Sept 2020, 6:00 pmClosed
CWE NO 2
CWE NO 2 DELHI CANTT
PROVN OF ONE COLD ROOM FOR DEPT OF PATHOLOGY AT BASE HOSPITAL UNDER GE (E/M) BASE HOSP, DELHI CANTT-10
2020_MES_367457_1
CWE/BH-11/2020-21
Open Tender
Civil Works
Item Rate
120 days
DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (E/M) BASE HOSPITAL
₹46,000
Yes
7 Nov 2020
7 Aug 2020
18 Sept 2020
7 Aug 2020
16 Sept 2020
4 Sept 2020
Amount
Surface excav n.exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches, n. exc.1.5m wide and n.exc. 1.5m deep; for foundation etc n.exc.10 Sqm on plan and getting out soft / loose soil complete all as specified and directed.
M&L PCC 1:4:8 type D-2 (using 40mm graded agg) in foundation, filling and mass concrete complete all as specified and directed.
M&L Brickwork with sub class 'B' bricks, straight or curved on plan exc 6m mean radius, built in Cement Mortar 1:6 complete all as specified and directed.
Returning filling including spreding leveling watering and well ramming in layout n. exc. 25cm in soft and loose soil complete all as specified and directed.
Removal of excavated material n. exc.50mtr and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and directed.
M&L MS TMT CRS bars 10mm dia and over cut to length ,bent to shape required including cranking , bending , hooking, for lintel and binding with MS wire not less than 0.9 mm dia or securing with clips complete all as specified and directed.
All as per item No. 7 aove but 5mm dia and over upto and including 10mm dia as in stirrups complete all as specified and directed.
M&L for RCC M-25 design mix using 20mm graded aggregates as in foundations, including rafts, footings, foundation beams, plinth beams, bases of columns etc; basement of slab etc complete all as specified and directed.
M&L for RCC M-25 design mix using 20mm graded aggregates as in Beams, cantilevers, bressumers, lintels over 1.5m span complete all as specified and directed.
M&L for RCC M-25 design mix using 20mm graded aggregates as in columns,pillars, piers, post and structs complete complete all as specified and directed.
M&L for RCC M-25 design mix using 20mm graded stone aggregate as in slabs supported on walls, beams and columns infloors, roofs, landing and ramp etc complete all as specified and directed.
Formwork (steel) flat to suspended slab such as roof slabs , floor slab, landings and similar work not exceeding 200 mm thick (horizontal or sloping) for flat surfaces complete all as specified and directed.
Formwork(steel) flat to edges of concrete such as roof slabs , floor slab, landings, window cill and similar work not exceeding 200 mm thick (horizontal or sloping) for flat surfaces complete all as specified and directed.
Formwork(steel) flat to sides and soffits of floor or roof beam, beam haunchings, girders, bressm-mers, lintel cantilever, shelves including overhangs etc also splays between floors and beams etc complete all as specified and directed.
Formwork(steel) to sides of concrete foundations, footings, bases of columns, rafts and raft beams, sides and soffits (in any) of foundation and plinth beams; and similar work; vertical or to batter etc complete all as specified and directed.
M& L for 15mm thick rendering in Cement Mortar 1:4 on fair/unfair surfaces finished even and smooth without using extra cement mixed with 3% water proofing compound complete all as specified and directed. Note: WPC shall be measured and paid separately under respectively item of this schedule.
M&L preparation of plastered surfaces of walls and applying two coats of cement base paint over one coat of primer on external new plastered surfaces complete all as specified and directed.
M&L for 10mm thick cement plaster in cement mortar 1:6 on other than fair face of brick surface finished even and smooth complete all as specified and directed.
M&L applying 1mm thick birla/JK wall care putty on new surface of wall then using sand paper for preparing smooth and even surface complete all as specified and directed.
M&L applying two coats of oil bound distemper over one coat of alkali resistant primer on newly putty surface of wall complete all as specified and directed.
M&L for 5mm thick cement plaster in cement mortar 1:3 on concrete surface of ceiling finished even and smooth without using extra cement complete all as specified and directed.
M&L applying 1mm thick birla/JK wall care putty on new surface of ceiling after preparation of newly plastered surface of the wall then applying sand paper for preparing smooth and even surface complete all as specified and directed.
M&L applying two coats of oil bound distemper over one coat of alkali resistant primer on newly putty surface of ceiling complete all as specified and directed.
M&L for 20 mm thick rendering on concrete surface of roof with cement mortar 1:4 finished even and fair including mixing of water proofing compound as per manufacturers instruction complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately
Supply only water proofing compound (powder) complete all as specified and directed.
M&L for roof treatment with polymeric membrance (APP based) with non woven polyster mat as reinforcement with following:- (a) M&L for cleaning the new plastered surface and providing & laying a coat of cold applied bitumen 85/25 based primer on entire surface @ 0.30 Ltr/Sqm on dry and clean surface. (b) M&L for providing & laying APP based polymeric membrane of 3 mm thickness of weight of 3.0 Kg/Sqm with non woven polyster fibre as reinforcement on primed surface by torch application with 15 cm end over laps & 10 cm side over laps etc as per manufacturers instruction. (c) M&L for finishing of top surface by a coat of aluminium paint complete all as specified and as directed. Make: Ms Sika India Pvt Ltd/ Ms Fosroc Chemicals/ Ms STP limited/ Ms IWL India limited/ Ms Tiki Tar Danosa (India) Pvt Ltd/ Ms Torchtar Membrane & Bitumen Pvt Ltd
M&L broken stone or boulders hard core of gauge n exc 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L 100mm thick PCC 1:4:8 type D-2 (using 40mm graded agg) in sub base complete all as specified and directed.
M&L 100mm thick PCC 1:2:4 type B1 (using 20mm graded agg) in sub base complete all as specified and directed.
M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurrry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 20 mm thick screed bedding in Cement Mortar 1:4 complete all as specified and directed.
M&L 75 mm thick PCC 1:3:6 type -C2 as in plinth protection complete all as specified and directed.
S&F 1.25mm thick steel rolling shutters, without ball bearing as specified including top cover, anchoring rod, hasp and staples and one shop coat of primer, erected in position including welding as indicated complete push, pull or manual type complete all as specified and directed.
M&L for surfaces of any description , over 10 cm in width or girth, not otherwise described, two coats of synthetic painting on new steel surfaces over coat of red oxide primer complete all as specified and directed.
Supply , installation testing and commissionng of pre fabricated cold room with two number of refrigeration system having outer dimensions 6100mm x 4550mm x 2440 (L x W x H) temperature between 2 degree centigrade to 8 degree centrigrade with connected accessories & two sets (one working & one stand by ) indoor and outdoor cooling and condensing unit with connected copper piping , control wiring, and display unit and temp controller, monitoring and automatic controlling panel as per OEM recomendation with following specification:- Make Carrier / Bluestar / Hitachi / Daikin (a) External Room Dimensions (Lx W x H) in mm 6100mm x 4550mm x 2440mm (b) Room Temperature Reqd. +2 to +8 Deg C (c) Ambient Temp +45 Deg. C (d) Door Opening 10 opening's per 24 hrs for 10 Sec each (e) Pull Down Time 12 HRs (f) Wall & Ceiling Panels Insulation thickness 80 mm thick PP/PP PIR Panel (g) Panel Type Camlock Panels (h) PIR Panel Density 45 + 2 per M3 (j) Door Type & Size 34" x 78" Flush Door (k) Door Leaf thickness 80mm (l) No of Door's 1 No Swing Door (m) Floor Insulation 80mm Flr Panel with Marine Ply 12mm & Al.Chq plate 1.2mm (n) Panel Finish PPGI both side with 0.4mm sheet thickness (o) No of machines 2 Sets (One working+ One Standby) (p) Condensing unit refrigeration capacity /Type :- 11.5 HP each unit / Air cooled corrosion resistant find & copper tubing (q) Evaporating unit refrigeration capacity /MOC :- 11.5 HP each unit / SS 304 grade corrosion resistant find & copper tubing
(A) (r) Auto Change over B/w Machines Automatic Required (s) Refrigerant R-410A/404A (t) Approved Compressor Type scroll hermatic (u) Expansion Valve Electronic only (v) Required CFM of Each Evaporator 4500 CFM each unit (w) No of Fans with Dia for each Evaporator 450 mm, 2 no's in each Evaporator (x) Required Air throw 25 Feet (y) Controller Microprocessor based with RS-485 Port (z) Electricity Supply 410V / 3 Phz / 50 Hz Accessories Included in the scope of Supply- 1. Door Alarm 2. Lock Defeat mechanism 3. Light Inside the cold room. 4. Handle, Hinges & Locks. 5. Microprocessor based digital control Panels 6. Evaporator 7. Panel Accessories & ground stands forunit and necessary Hardwares.
(B) Techanical parameters of Outdoor Unit:- Refrigerant - R410A/404A Supply voltage of unit :- 380-415V/ 3 ph / 50HZ Compressor Make : Emerson/ danfoss Type of Oil:- FV50S Compressor oil charge (L):- 0.72 No. Fan:- 01 daimeter of fan ( mm):- 500 Fan speed ( In RPM) :- 300-850 Maximum Power of Unit(KW) :- 3.2 Noise of Unit (dBA @ 1m):- 53 Nominal Running current of unit (A):- 9 Max Running current (A):- 16 Diameter of suction pipe :- 1/2 inch Diameter of liquid pipe :- 3/8 inch
(C) Techanical parameters of Indoor Unit:- Refrigerant - R410A Refrigeration capacity : 30000 BTU/Hr Supply voltage of unit :- 230V/ 1 ph / 50HZ Total air flow : 4500 cfm Air throw :- 25 Ft daimeter of fan ( mm):- 450 No. of Fan Per Unit :- 3 Coil Detail:- FPI -08 Nos. Sheet Metal:- GI, Powder coated , RAL code 9003 Piping Detail:- Suction connection :- 7/8 inch Discharge connection :- 3/8 inch
Supply, installing, testing and commissioning of Outdoor type Feeder Piller floor mounted suitable for 415 volt, 3 phase 4 wire 50 Hz, AC supply system having bus bar chamber with duly insulated Aluminium Bus bars of rating 500 Amps mounted on epoxy/SMC type insulator and the minimum inside depth of panel is not less than 500mm. The panel shall be dust and vermin proof IP 54 class protection and make of 3.15mm width CRCA sheet and 50 mm x 50 mm x 6mm thick angle iron frame work 90 Cm height and grouded 45 Cm in PCC , powder coated finish outside and inside, both side (front and rear)openable type for cable entry with double door shutter and locking arrangement, internal wiring with PVC insulated flexible copper conductor FRLS cable IS 694 marked of adequate size but not less than 1.5 sq mm complete with the following incoming and outgoing feeders Note:- PCC & Excavation inclusive in qouting rates (a) Incoming :- (i) MCCB TP + NL , LT 415 Volts, 50 Hz, AC grade, 315Amps rating and 36 KA : 01 Nos. (b) Outgoing:- (i) MCCB 4 pole , LT 415 Volts, 50 Hz, AC grade,160 amps rating and 36 KA rupturing capacity. Nos - 02 (ii) MCCB 4 pole, LT 415 volts, 50 Hz AC grade, 100 amps rating and 25KA rupturing capacity. Nos - 03
Supply and laying cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables heavy duty) 1100 Volts grade with standard aluminium conductor complete all as specified and directed for the following size:-
240 Sqmm 3 ½ core
70 Sqmm 3 ½ core
25 sqmm , 4 core
Supply and laying common burnt bricks of sub class ‘B’ laid flat at right angle on the cable complete all as directed in trenches for cable protection complete all as specified and directed
M&L for providing dry river sand as in sand cushioning to under ground electric cable including punning down of sand in layer all as specified and directed by Engg-in-Charge. Note: for measurement purpose punned thicness of sand only will be considered.
S&F in repair distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof MCB DB, TPN 8 way with 200 Amp rated copper busbar, 415 volts with in built MCCB 125Amp, 10KA, 01 No earth bar IP 43 protection, flush to wall complete all as specified and directed. Make: Legrand Model No 507747 or equivalent in L&T/ ABB/ Scheneider/ Seimens/ C&S Electric/ Havells/ Benlo/ Crystal
S & F MCB TPN 63 Amp complete all as specified and directed.
S&F MCB SP 240 volts, 63 Amp complete all as specified and directed.
M & L submain wiring using four run PVC insulated FRLS Copper conductor 16 sqmm with rigid non metalic PVC conduit of size 40 mm dia medium grade inclusive of boxes (junction/terminal) all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings fixed on wall/ceiling with saddles PVC with earth continuity wire copper conductor PVC insulated unsheathed 16 Sq mm etc complete all as specified and directed. Note: four runs of 16 sqmm copper FRLS cable & one run of 16 sqmm copper cable in and including 40 mm PVC conduit medium grade will be measured as one unit.
M & L submain wiring using four run PVC insulated FRLS Copper conductor 25 sqmm with rigid non metalic PVC conduit of size 40 mm dia medium grade inclusive of boxes (junction/terminal) all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings fixed on wall/ceiling with saddles PVC with earth continuity wire copper conductor PVC insulated unsheathed 40 Sq mm etc complete all as specified and directed. Note four runs of 25 sqmm copper FRLS cable & one run of 25 sqmm copper cable in and including 40 mm PVC conduit medium grade will be measured as one unit.
M&L for earthing complete with galvanised iron earth plate electrode 600x600x6.3 mm thick, burried directly in ground (earth pit not less than 2.25 mtrs deep below normal grond level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth GI wire of size 4mm by means of GI nut, bolts and washers or steel as shown in electrical plate No. 5 of SSR part-I and connected to earth GI wire on main switch board all as specified and testing on completion including provision of earth wire protection by 15 mm dia GI Tubing, light grade and watering pipe shall be 20 mm bore GI light grade including excavation & earth work, PCC pit with CI cover, charcoal, salt, funnel, wire mesh,GI strip up to 7.5 mtrs length complete all as specified and directed.
M&L for point wiring with normal switches with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed (FRLS) cable 1100 Volts grade, drawn through concealed Conduit including cadmium plated screws as per IS, including replacement of 3 mm thick phenolic laminated sheet top covers on and including sunk type CI/steel terminal boxes concealed in wall including 1.5 Sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly for One light point controlled by one switch 5 Amps one way single pole complete all as specified and directed.
All as per item No. 46 above but one fan point controlled by one switch 5 Amps one way single pole complete all as specified and directed.
All as per item No. 46 above but one three pin 5 Amps socket out let on same board complete all as specified and directed.
All as per item No. 46 above but point wiring of copper cable multi stranded 2.5 Sqmm size for 15 Amps socket outlet on independent board with 2.5 Sqmm size of earth conductor complete all as specified and directed.
Supply and fix in repair Switch Piano type, white polycarbonate body, single pole, one way 5/6 amp, 230 V, including connecting complete all as specified and directed.
Supply and fix in repair Switch Piano type, white polycarbonate body, single pole, one way 16 amp, 230 V, including connecting complete all as specified and directed.
Supply and fix in repair socket white polycarbonate body, 6A- 230 V, 2/3 pin combined, including connecting complete all as specified and directed.
Supply and fix in repair socket white polycarbonate body, 16A- 230 V, 3 pin combined, including connecting complete all as specified and directed.
Supply and fix in repair normal type stepped type electronic fan regulator, white polycarbonate body, flush type, 230 V, including connecting complete all as specified and directed.
S & F in replacement modular type Ceiling rose, PVC/ polycarbonate, isolated body type three terminal, 240 volt complete all as specified and directed.
M & L Sub main wiring using two single core PVC insulated FRLS cable 4 sqmm copper conductor multi stranded and 4.0 sqmm copper conductor insulated cable using as earth wire and drawing in to PVC conduit complete all as specified and directed. Note: Two runs of 4sqmm copper FRLS cable & one run of 4.0 sqmm copper cable in and including 25mm PVC conduit medium grade will be measured as one unit.
S & F distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 4 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand Model: 507610 or equivalent in L&T/ ABB/ Scheneider/ Seimens/ C&S Electric/ Havells/ Benlo/ Crystal
S & F MCB SPN, 240 Volts, 63 Amps complete all as specified and directed.
S & F MCB SP, 240 Volts, 16 Amps complete all as specified and directed.
S & F MCB SP, 240 Volts, 6 Amps complete all as specified and directed.
S & F energy efficient LED light fitting 18/20 Watt,230 Volt of 1200 mm + 50 mm length along with fixture, heat sink, environmental friendly, energy efficient, wall mounted batten integrated electronic driver complete all as specified and directed. Make: Halonix Cat No. HLB-03-18-CW-AL or equivalent in Philips/ Bajaj/ Crompton Greaves/ Benlo/ C&S Electric/ Havells
S&F LED blg security Light fitting 25 watt, system efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, including bracket & connecting accessories complete all a specified and directed by engineer in charge. Make: CG Cat part No LSTP-25CDL or equivalent in Philips/ Bajaj/ C&S Electric/ Benlo/ Havells/ Halonix
S and F ceiling fan 1200mm, BEE 5 star rating incl suitable size of down rod and flexible wire 2 core of size 23 X .0076' and clamps and nut and bolts complete all as specified and directed.
Verma Enterprises
M/s Birja Nand
DP Traders
Vishal Traders
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .