Nitin Bhoyar Sr DGM
POWERGRID WR I Nagpur Pincode 440026
Defect rectification work of 400kV DC Quad Wardha Aurangabad Transmission Line D1 Package Upgradable to 1200kV SC associated with Mundra Regional System for WR
WR I CandM 2020 NIT 36 Package A Rfx 5002001453
Open
Power/Energy Projects/Products
Works
400kV DC Quad Wardha Aurangabad Transmission Line D1 Package
₹2.0 L
18 Sept 2020
18 Sept 2020
12 Oct 2020
18 Sept 2020
9 Oct 2020
18 Sept 2020
SUPPLY PORTION
Part-A
Supply of Earthwire VD as per Technical Specification
Supply of Copper Bond in 19/3.00mm G.S. Earthwire as per Technical Specification
Supply of Suitable 19/3.00mm G.S. Earthwire jumper cone only as per Technical Specification
Supply of missing cotterpins, nut/bolts as per approved POWERGRID Drawing and Specification
Supply of Counter poise earthing as per Technical Specification
Supply of various missing/Loose nuts and bolts, washers in towers, accessories etc. as per TS
Supply of various tower Members, plates etc. in towers etc. as per TS
Supply of Arching horn of hardware fittings as per Requirement
Supply of Corona Ring of hardware fittings as per Requirement
Supply of Grading Ring of CLR Insulators as per Requirement
Supply of Jumper Bolt of hardware fittings as per Requirement
Supply of Tower Accessories: Number Plate
Supply of Tower Accessories: Phase Plate (Set of three)
Supply of Tower Accessories: Circuit Plate (Set of two)
Supply of Tower Accessories: Anti Climbing Device including Barbed Wire, etc.
Supply of missing Spacer cap as per identified make
Part-B
Supply of Earthwire VD as per Technical Specification
Supply of Copper Bond in 19/3.00mm G.S. Earthwire as per Technical Specification
Supply of Suitable 19/3.00mm G.S. Earthwire jumper cone only as per Technical Specification
Supply of missing cotterpins, nut/bolts as per approved POWERGRID Drawing and Specification
Supply of Counter poise earthing as per Technical Specification
Supply of various missing/Loose nuts and bolts, washers in towers, accessories etc. as per TS
Supply of various tower Members, plates etc. in towers etc. as per TS
Supply of Arching horn of hardware fittings as per Requirement
Supply of Corona Ring of hardware fittings as per Requirement
Supply of Grading Ring of CLR Insulators as per Requirement
Supply of Jumper Bolt of hardware fittings as per Requirement
Supply of Tower Accessories: Danger Plate
Supply of Tower Accessories: Number Plate
Supply of Tower Accessories: Phase Plate (Set of three)
Supply of Tower Accessories: Circuit Plate (Set of two)
Supply of Tower Accessories: Anti Climbing Device including Barbed Wire, etc.
Supply of missing Spacer cap as per identified make
Supply of Earthwire Suspension Clamp suitable for Suitable 19/3.00mm G.S. Earthwire
Supply of Armour rod suitable for Quad ACSR moose Suspension Hardware fitting of identified make
INSTALLATION PORTION
Part-A
Removal of excess soil or Soil filling in Foundation Chimney and compaction as per requirement, of technical Specification and Engg. I/c
Replacement of damaged insulator (/String) with healthy one provided by POWERGRID as per TS and direction of Engineer I/c
Installation of Earthwire VD(OSM)/Fixing of Loose Earthwire VD as per requirement of TS
Installation of New Copper Bond (OSM)/Fixing of Loose Copper Bond in Earthwire by providing suitable Nut Bolts washers etc.
Installation of Earthwire jumper(OSM)/ Clipping/Tightening of Loose Earthwire Jumper by providing suitable nut bolts, washers etc. as per Drg.
Installation of Quad Rigid Spacer(OSM)/ Tightening of Loose Quad Rigid Spacer, fixing of spacer cap etc.and as per TS
Installation of Quad Spacer Damper(OSM)/ Tightening of Loose Spacer Damper, fixing of spacer cap and as per TS
Clipping/Fixing of Loose Armour Rod in Suspension (Per Fitting)
Coping work in Tower leg as per POWERGRID Specification
Fixing of missing cotterpins as per approved POWERGRID Drawing and Specification
Installation of Counter poise earthing(OSM)/Fixing/Connection of loose/open Counterpoise earthing as per POWERGRID Technical Specification
Repair of damaged Chimney/ Extra Steel Cutting
Fixing of Repair sleeve (Powergrid Provided) over damaged Moose conductor
Fixing of danger /number/circuit/ phase plate/anticlimbing device (ACD)
Identification and fixing of missing Bolts & Nuts, washers Breaking of Antitheft Bolts, Fixing of Step bolts in towers, etc.
Identification and fixing/installation of missing/open Tower members,plates, Fixing of missing B&N, step bolts, Drilling of Foul/mismatch holes, Drilling of Holes for fixing Tower ccessories, required site fabrication, Tightening of Loose Tower Member, Tightening of Loose/Bolts & Nuts, Changing of Undersize B&B as per POWERGRID Technical Specification, Replacement of Bend members, fixing of hanging members to the satisfaction of Engineer incharge
Inst/tightening. of Missing/Loose Arching horn of hardware fittings
Identification of make & Installation of matching Missing Corona/Grading Ring of hardware fittings, Insulators, etc.
Zinc Rich Painting of Tower Nuts/Bolts as per POWERGRID Specification
Tack welding of Nuts/Bolts as per POWERGRID Specification
Fixing of Conductor Jumper Bolts & Tightening of Loose jumper B&N
Stub Encashment
Clipping of Quad ACSR moose Conductor and transportation of roller, etc. to store.
Part-B
Removal of excess soil or Soil filling in Foundation Chimney and compaction as per requirement, of technical Specification and Engg. I/c
Replacement of damaged insulator (/String) with healthy one provided by POWERGRID as per TS and direction of Engineer I/c
Installation of Earthwire VD(OSM)/Fixing of Loose Earthwire VD as per requirement of TS
Installation of New Copper Bond (OSM)/Fixing of Loose Copper Bond in Earthwire by providing suitable Nut Bolts washers etc.
Installation of Earthwire jumper(OSM)/ Clipping/Tightening of Loose Earthwire Jumper by providing suitable nut bolts, washers, clamps etc. as per Drg.
Installation of Quad Rigid Spacer(OSM)/ Tightening of Loose Quad Rigid Spacer, fixing of spacer cap etc.and as per TS
Installation of Quad Spacer Damper(OSM)/ Tightening of Loose Quad Spacer Damper, fixing of spacer cap and as per TS
Clipping/Fixing of Loose Armour Rod in Suspension (Per Fitting)
Coping work in Tower leg as per POWERGRID Specification
Fixing of missing cotterpins as per approved POWERGRID Drawing and Specification
Installation of Counter poise earthing(OSM)/Fixing/Connection of loose/open Counterpoise earthing as per POWERGRID Technical Specification
Repair of damaged Chimney/ Extra Steel Cutting
Fixing of Repair sleeve (Powergrid Provided) over damaged Moose conductor
Fixing of danger /number/circuit/ phase plate/anticlimbing device (ACD)
Identification and fixing of missing Bolts & Nuts, washers Breaking of Antitheft Bolts, Punching of Bolts, Fixing of Step bolts in towers, etc.
Identification and fixing/installation of missing/open Tower members,plates, Fixing of missing B&N, step bolts, Drilling of Foul/mismatch holes, Drilling of Holes for fixing Tower ccessories, required site fabrication, Tightening of Loose Tower Member, Tightening of Loose/Bolts & Nuts, Changing of Undersize B&B as per POWERGRID Technical Specification, Replacement of Bend members, fixing of hanging members to the satisfaction of Engineer incharge
Inst/tightening. of Missing/Loose Arching horn of hardware fittings
Identification of make & Installation of matching Missing Corona/Grading Ring of hardware fittings, Insulators, etc.
Tightening & Fixing of Loose B&N of Corona/Grading Ring of Suitable size
Zinc Rich Painting of Tower Nuts/Bolts as per POWERGRID Specification
Tack welding of Nuts/Bolts as per POWERGRID Specification
Fixing of Conductor Jumper Bolts & Tightening of Loose jumper B&N
Stub Encashment
Clipping of Quad ACSR moose Conductor and transportation of roller, etc. to store.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
2-12-Std tender drg.pdf
pdf • 4.61 MB
2-7-Erected Accessories Drawings.pdf
pdf • 0.76 MB
2-15-Defect_list-2.pdf
pdf • 6.91 MB
2-14-Defect_list-1.pdf
pdf • 7.49 MB
Price_schedule.xls
xls • 2.21 MB
2-13-SFQP-TL.pdf
pdf • 4.32 MB
2-9-Erected QT Drg.pdf
pdf • 3.30 MB
2-8-Erected DIS & SSISP Drg.pdf
pdf • 4.82 MB
0-TENDER DETAILS.docx
docx • 0.11 MB
1-1-IFB.docx
docx • 0.13 MB
1-2-ITB.doc
doc • 1.81 MB
1-3- BDS.doc
doc • 1.66 MB
1-3A-Annex A (BDS)-QR.pdf
pdf • 0.15 MB
1-4-GCC.doc
doc • 1.75 MB
1-5-SCC.doc
doc • 1.64 MB
1-6-Forms and Proc.doc
doc • 1.66 MB
2-0-A-Model Rules & Safety Code.doc
doc • 1.66 MB
2-0-B-Registers.pdf
pdf • 0.12 MB
2-1-TS Sec 01.pdf
pdf • 0.40 MB
2-10-Final Bird Guard Drg.pdf
pdf • 0.79 MB
2-11-Raised Chimney Drg.pdf
pdf • 0.07 MB
2-2-TS Sec 02.pdf
pdf • 0.28 MB
2-3-TS Sec 03.pdf
pdf • 0.86 MB
2-4-TS Sec 04.pdf
pdf • 0.73 MB
2-5-Erected 400kV 120KN Insulator Drg.pdf
pdf • 1.32 MB
2-6-Erected 400kV 160KN Insulator Drg.pdf
pdf • 0.49 MB
3-1-Attach Bid Forms-I.xls
xls • 2.65 MB
3-2-BOM.xlsx
xlsx • 0.07 MB
Annexure-A-Corrigendum.doc
doc • 1.63 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .