Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹21.5 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹22.5 L+₹1.0 L (4.76%)Rejected-Finance B 17 2 GALI NO 20 JITAR NAGAR NEAR PARVANA ROAD KRISHNA NAGAR EST DELHI 51 | NEW DELHI | DELHI | 110001 | 2 | Rejected-Finance 2 | |
| 3 | 3₹22.7 L+₹1.2 L (5.45%)Rejected-Finance A 20 COMMERCIAL COMPLEX DR MUKHERJEE NAGAR KINGSWAY CAMP DELHI 110009 | NORTH | DELHI | 110009 | 3 | Rejected-Finance 3 |
Tender Value
₹23.8 L
EMD Value
₹47,615
Closing Date
19 Oct 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EEE-II/CLZ
EEE-II/CLZ
Improvement of Cabling at various Blocks in RBIPMT Hospital.
2023_MCD_170715_1
EEE-II/TC/2023-24/19.1
Open Tender
Electrical Works
Item Rate
120 days
EEE-II/CLZ
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹47,615
5 Apr 2024
13 Oct 2023
20 Oct 2023
13 Oct 2023
19 Oct 2023
13 Oct 2023
Amount
122.1.17:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3.5C*35 sqmm
122.1.19:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3.5C*70 sqmm
122.1.23:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3.5C*185 sqmm
122.1.24:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3.5C*240 sqmm
122.1.25:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3.5C*300 sqmm
OD8938/2023-2024:(DSR-2022-7.1.1) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. (a) Upto 35 sq. mm
OD8939/2023-2024:(DSR-2022-7.1.2) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. (a) Above 35 sq. mm and upto 95 sq. mm
OD8940/2023-2024:(DSR-2022-7.1.3) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. (c) Above 95 sq. mm and upto 185 sq. mm
OD8941/2023-2024:(DSR-2022-7.1.4) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. (d) Above 185 sq. mm and upto 400 sq. mm
OD8942/2023-2024:(DSR-2022-7.5.1) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. (a) Upto 35 sq. mm
OD8943/2023-2024:(DSR-2022-7.5.2) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. (b) Above 35 sq. mm and upto 95 sq. mm
OD8950/2023-2024:(DSR-2022-7.5.3) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. (c) Above 95 sq. mm and upto 185 sq. mm
OD8951/2023-2024:(DSR-2022-7.5.4) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. (d) Above 185 sq. mm and upto 400 sq. mm
OD8954/2023-2024:(DSR-2022-7.6.1) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. (a) Upto 35 sq. mm
OD8955/2023-2024:(DSR-2022-7.6.2) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. (b) Above 35 sq. mm and upto 95 sq. mm
OD8956/2023-2024:(DSR-2022-7.6.3) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. (c) Above 95 sq. mm and upto 185 sq. mm
OD8957/2023-2024:(DSR-2022-7.6.4) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. (d) Above 185 sq. mm and upto 400 sq. mm
OD8958/2023-2024:(DSR-2022-7.7.1) Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. (a) Upto 35 sq. mm (clamped with 1mm thick saddle)
OD8959/2023-2024:(DSR-2022-7.7.2) Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. (b) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
OD8960/2023-2024:(DSR-2022-7.7.3) Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. (c) Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
OD8961/2023-2024:(DSR-2022-7.7.4) Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. (d) Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
OD8982/2023-2024:(DSR-2022-9.1.21) Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (a) 3½ X 35 sq. mm (32mm)
OD8983/2023-2024:(DSR-2022-9.1.23) Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (b) 3½ X 70 sq. mm (38mm)
OD8985/2023-2024:(DSR-2022-9.1.29) Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (d)3½ X 240 sq. mm (62mm)
OD8986/2023-2024:(DSR-2022-9.1.30) Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (e) 3½ X 300 sq. mm (70mm)
OD8987/2023-2024:(DSR-2022-2.2.14) Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (a) 125 A,36KA,FPMCCB
OD8988/2023-2024:(DSR-2022-2.2.16) Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (b) 250 A,36KA,FPMCCB
OD8989/2023-2024:(DSR-2022-2.2.18) Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (c) 400 A,50KA,FPMCCB
OD8990/2023-2024:(DSR-2022-2.4.1) Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 4 way (4 + 12), Double door
OD8991/2023-2024:(DSR-2022-2.10.1) Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single Pole
OD8992/2023-2024:(DSR-2022-2.11) Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
OD8993/2023-2024:(DSR-2022-2.15.3) Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 amp
OD8995/2023-2024:(DSR-2022-2.24.1) Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. (a) For 4 way, Double door TPN MCBDB
OD8996/2023-2024:(DSR-2022-5.2) Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
OD8998/2023-2024:(DSR-2022-5.9) Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
OD8999/2023-2024:(DSR-2022-5.15) Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
OD9000/2023-2024:(DSR-2022-7.9) Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
OD9001/2023-2024:(DSR-2022-2.21) Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
bharat electricals & electronics
ARPIT ELECTRIC CO.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .