Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-Finance | ₹30.7 L | L1 | Accepted-Finance ok |
| 2 | L2₹30.8 L+₹12,168.75 (0.40%)Accepted-Finance | ₹30.8 L+₹12,168.75 (0.40%) | L2 | Accepted-Finance ok |
| Sl No | Description | Qty | Unit | KAMLESH ENGINEERING WORKS L1 | SUSHMA ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.00 | Supply Fixing of aluminum armored cable (25sq.mm × 4-core) from Main Supply of DJB Pump House to Fine Bar Screen along with providing and fixing of new bus bar to supply &fixing of electric connection from the supply systemin main bus bar by MCB of size 100A, 4-Pole before supply after supply also providing 100A MCB on both sides | 1 | Job | 1,55,950 ₹1,84,021 Lowest | 1,56,712.5 ₹1,84,920.75 |
| 2.00 | Electrical Control Panels & Infrastructure:
2(i) Providing & Fixing of Electric Panel ofsize48" ×48" ×12" for hoist of 10T —1 No. &5T —1 No. for wire of electric motor &panel
2(ii) Fixing of MCB contractor, wiring etc. for 10T capacity as well as 5T capacity
2(iii) Remote panel of10Tcapacity&5Tcapacityofsize18" ×15" with control of Push Button(i) ON-OFF,(ii) LEFT-RIGHT,(iii) UP-DOWN, (iv) NORTH-SOUTH
2(iv) Wiring of Electric Panel, Motor contractor, MCB for 10T capacity &5T capacity with wire of electric motor &panel
2(v) For10TCapacity: Fixing of MCB 32A—1 No., Contractor 32A—2 Nos., Movement Left-Right —2 Nos., North-South Contractor 18A —2 Nos., North-South Contractor 9A —2 Nos.
2(vi) FixingofElectriccoppercablefor10T: 4sq.mm×3-core, 1.5 sq.mm× 3-core, 2.5sq.mm× 6-core, 1.5sq.mm× 6-core, 1 sq.mm × 10-core
2(vii) Remote panel size 18" × 15" with double-door type for10T capacity for Push Button(i)UP-DOWN, (ii)RIGHT-LEFT, (iii) NORTH-SOUTH
2(viii) For5T Capacity: Fixing of contractor: MCB 25A—1No., Contractor 18A —2 Nos., Contractor 15A —2 Nos., Contractor 9A —2 Nos.
2(ix) Copperwiringofpanelfor5Tcapacity:2.5sq.mm×3-core,
2.5sq.mm×6-core,1.5sq.mm×6-core,1sq.mm×12-core,
1.5sq.mm×3-core | 1 | No. | 2,08,000 ₹2,45,440 Lowest | 2,08,950 ₹2,46,561 |
| 3.00 | from Main Supply of DJB Pump House to Coarse Bar Screen along with providing and fixing of new bus bar to supply &fixing of electric connection from the supply systemin main bus bar byMCB ofsize 100A, 4-Pole before supply&after supply also providing 100A MCB on both sides | 1 | Job | 1,55,950 ₹1,84,021 Lowest | 1,56,712.5 ₹1,84,920.75 |
| 4.00 | ControlPanelAssembly&Infrastructure:
4(i) ElectricPanel ofsize36" × 48" hut-typeforhoistof5T capacity—4Nos.withMCB25A—4Nos., Contractor18A
—8Nos., Contractor12A—8Nos., Contractor9A—8Nos.
4(ii) Fixing of MCB contractor, wiring etc. for 5T capacity —4 Nos. for electric hoist (Copper cables : 2.5sq.mm × 6-core,
2.5sq.mm×3-core,1.5sq.mm×6-core,1sq.mm×12-core,
1.5sq.mm×6-core)
4(iii) Remote panel for5Tcapacity—4Nos. ofsize12" × 12" with control of Push Button(i) ON-OFF,(ii) LEFT-RIGHT,(iii) UP-DOWN, (iv) Lengthwise
4(iv) Wiring of Electric Panel, Motor contractor, MCB for 5T capacity —4 Nos. | 1 | Job | 1,98,000 ₹2,33,640 Lowest | 1,99,000 ₹2,34,820 |
| 5.00 | Supply & Fixing of aluminium armoured cable (25sq.mm × 4-core)along with providing and fixing of new bus bar to
supply &fixing of electric connection from the supply systemin main bus bar by MCB of size 100A, 4-Pole before supply & after supply also providing 100A MCB on both sides | 1 | Job | 1,55,950 ₹1,84,021 Lowest | 1,56,712.5 ₹1,84,920.75 |
| 6.00 | Control Panel Assembly (5TCapacity×2Units):
6(i) Electric Panel of size 20" × 36" hut-type door with 2 Nos. Base frame for electric panelfor hoist of 5T capacity —2 Nos.withwire(2.5sq.mm×6-core,1.5sq.mm×6-core,1 sq.mm × 12-core)
6(ii) Fixing of MCB contractor, wiring etc. for5Tcapacity—2 Nos.withMCB25A—4Nos., Contractor18A—8Nos., Contractor15A—8Nos., Contractor25A—2Nos., Contractor 9A —2 Nos.
6(iii) Remote panel for5Tcapacity—2Nos. ofsize18" × 15" with control of Push Button(i) ON-OFF, (ii) LEFT-RIGHT, (iii) UP-DOWN, (iv) Lengthwise
6(iv) Wiring of Electric Panel, Motor contractor, MCB for 5T capacity—2Nos. (2.5sq.mm× 3-core, 2.5sq.mm× 6-core, 1 sq.mm × 6-core, 1.5 sq.mm × 6-core, 1.5 sq.mm × 3-core) | 1 | Job | 99,000 ₹1,16,820 Lowest | 99,500 ₹1,17,410 |
| 7.00 | Providing and fixing Distribution Panel of size 48" × 64" height double-door hut-type Electric Panel to control of supply from Haiderpur Plant to Twin Main Control Panel with Main MCB 100A—2 Nos., Changeover 100A —2 Nos., MCB 32A (4-Pole) —8 Nos., Connector 100A —8 Nos., Bus Bar 100A | 1 | No. | 1,68,500 ₹1,98,830 Lowest | 1,69,150 ₹1,99,597 |
| 8.00 | Providing and laying of PVC insulated and PVC sheathed power cable of 1.1 KV grade (Upto35 sq.mm aluminium armoured) direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required | 700 | Mtr. | 7,49,000 ₹8,83,820 Lowest | 7,50,400 ₹8,85,472 |
| 9.00 | Supply & Fixing of aluminium armoured cable (25 sq.mm × 4-core) along with providing and fixing of new bus bar to supply & fixing of electric connection from the supply systemin main bus bar by MCB ofsize100A, 4-Polebefore
supply&aftersupplyalsoproviding100AMCBonbothsides | 1 | Job | 1,55,950 ₹1,84,021 Lowest | 1,56,712.5 ₹1,84,920.75 |
| 10.00 | Electrical Control Panels (Mixed Capacity- 5T × 2 &3T × 2):
10(i) Electric Panel of size 36" × 48" double-door for hoist of 5T capacity—2Nos. &3Tcapacity—2Nos.withbaseframe
10(ii) Fixing of MCB connector, limit switch, wiring etc. for5T capacity—2Nos.&3Tcapacity—2Nos.with MCB25A— 4 Nos., Contractor 25A —4 Nos., Contractor 18A —8 Nos., Contractor15A—8Nos., Contractor9A—8Nos.
10(iii) Remote panel for5Tcapacity—2Nos. ofsize18" × 15" with control of Push Button(i) ON-OFF,(ii) LEFT-RIGHT,(iii) UP-DOWN, (iv) Lengthwise with wire (2.5 sq.mm × 6-core, 1.5 sq.mm×3-core, 1.5sq.mm×6-core, 2.5sq.mm×3-core, 1 sq.mm × 12-core)
10(iv) Wiring of Electric Panel, Motor contractor, MCB for 5T capacity & 3T capacity | 1 | Job | 1,98,000 ₹2,33,640 Lowest | 1,99,000 ₹2,34,820 |
Tender Value
Refer Docs
EMD Value
₹62,000
Closing Date
3 Aug 2026, 2:30 pmClosed
EE EnM HP I
DELHI JAL BOARD GOVT OF NCT OF DELHI OFFICE OF THE EXECUTIVE ENGINEER EnM HP I HAIDERPUR WATER WORKS DELHI 110085
Modification of Electrical Panels of Globe Make EOT Cranes installed at Raw Water Pump House I n II n Twin main point Bas Screens under HPWW
2026_DJB_295932_1
NIT NO. 04(2026-27) HP-I
Open Tender
Miscellaneous Works
Works
EE EnM HP I
Please refer tender documents
3 documents required · 3 mandatory
₹500
SAB PAISA PORTAL Ac No. 50448339804
₹62,000
5 Aug 2026
27 Jul 2026
3 Aug 2026
27 Jul 2026
3 Aug 2026
27 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply Fixing of aluminum armored cable (25sq.mm × 4-core) from Main Supply of DJB Pump House to Fine Bar Screen along with providing and fixing of new bus bar to supply &fixing of electric connection from the supply systemin main bus bar by MCB of size 100A, 4-Pole before supply after supply also providing 100A MCB on both sides | 1 | Job | - | - |
| 2 | Electrical Control Panels & Infrastructure:
2(i) Providing & Fixing of Electric Panel ofsize48" ×48" ×12" for hoist of 10T —1 No. &5T —1 No. for wire of electric motor &panel
2(ii) Fixing of MCB contractor, wiring etc. for 10T capacity as well as 5T capacity
2(iii) Remote panel of10Tcapacity&5Tcapacityofsize18" ×15" with control of Push Button(i) ON-OFF,(ii) LEFT-RIGHT,(iii) UP-DOWN, (iv) NORTH-SOUTH
2(iv) Wiring of Electric Panel, Motor contractor, MCB for 10T capacity &5T capacity with wire of electric motor &panel
2(v) For10TCapacity: Fixing of MCB 32A—1 No., Contractor 32A—2 Nos., Movement Left-Right —2 Nos., North-South Contractor 18A —2 Nos., North-South Contractor 9A —2 Nos.
2(vi) FixingofElectriccoppercablefor10T: 4sq.mm×3-core, 1.5 sq.mm× 3-core, 2.5sq.mm× 6-core, 1.5sq.mm× 6-core, 1 sq.mm × 10-core
2(vii) Remote panel size 18" × 15" with double-door type for10T capacity for Push Button(i)UP-DOWN, (ii)RIGHT-LEFT, (iii) NORTH-SOUTH
2(viii) For5T Capacity: Fixing of contractor: MCB 25A—1No., Contractor 18A —2 Nos., Contractor 15A —2 Nos., Contractor 9A —2 Nos.
2(ix) Copperwiringofpanelfor5Tcapacity:2.5sq.mm×3-core,
2.5sq.mm×6-core,1.5sq.mm×6-core,1sq.mm×12-core,
1.5sq.mm×3-core | 1 | No. | - | - |
| 3 | from Main Supply of DJB Pump House to Coarse Bar Screen along with providing and fixing of new bus bar to supply &fixing of electric connection from the supply systemin main bus bar byMCB ofsize 100A, 4-Pole before supply&after supply also providing 100A MCB on both sides | 1 | Job | - | - |
| 4 | ControlPanelAssembly&Infrastructure:
4(i) ElectricPanel ofsize36" × 48" hut-typeforhoistof5T capacity—4Nos.withMCB25A—4Nos., Contractor18A
—8Nos., Contractor12A—8Nos., Contractor9A—8Nos.
4(ii) Fixing of MCB contractor, wiring etc. for 5T capacity —4 Nos. for electric hoist (Copper cables : 2.5sq.mm × 6-core,
2.5sq.mm×3-core,1.5sq.mm×6-core,1sq.mm×12-core,
1.5sq.mm×6-core)
4(iii) Remote panel for5Tcapacity—4Nos. ofsize12" × 12" with control of Push Button(i) ON-OFF,(ii) LEFT-RIGHT,(iii) UP-DOWN, (iv) Lengthwise
4(iv) Wiring of Electric Panel, Motor contractor, MCB for 5T capacity —4 Nos. | 1 | Job | - | - |
| 5 | Supply & Fixing of aluminium armoured cable (25sq.mm × 4-core)along with providing and fixing of new bus bar to
supply &fixing of electric connection from the supply systemin main bus bar by MCB of size 100A, 4-Pole before supply & after supply also providing 100A MCB on both sides | 1 | Job | - | - |
| 6 | Control Panel Assembly (5TCapacity×2Units):
6(i) Electric Panel of size 20" × 36" hut-type door with 2 Nos. Base frame for electric panelfor hoist of 5T capacity —2 Nos.withwire(2.5sq.mm×6-core,1.5sq.mm×6-core,1 sq.mm × 12-core)
6(ii) Fixing of MCB contractor, wiring etc. for5Tcapacity—2 Nos.withMCB25A—4Nos., Contractor18A—8Nos., Contractor15A—8Nos., Contractor25A—2Nos., Contractor 9A —2 Nos.
6(iii) Remote panel for5Tcapacity—2Nos. ofsize18" × 15" with control of Push Button(i) ON-OFF, (ii) LEFT-RIGHT, (iii) UP-DOWN, (iv) Lengthwise
6(iv) Wiring of Electric Panel, Motor contractor, MCB for 5T capacity—2Nos. (2.5sq.mm× 3-core, 2.5sq.mm× 6-core, 1 sq.mm × 6-core, 1.5 sq.mm × 6-core, 1.5 sq.mm × 3-core) | 1 | Job | - | - |
| 7 | Providing and fixing Distribution Panel of size 48" × 64" height double-door hut-type Electric Panel to control of supply from Haiderpur Plant to Twin Main Control Panel with Main MCB 100A—2 Nos., Changeover 100A —2 Nos., MCB 32A (4-Pole) —8 Nos., Connector 100A —8 Nos., Bus Bar 100A | 1 | No. | - | - |
| 8 | Providing and laying of PVC insulated and PVC sheathed power cable of 1.1 KV grade (Upto35 sq.mm aluminium armoured) direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required | 700 | Mtr. | - | - |
| 9 | Supply & Fixing of aluminium armoured cable (25 sq.mm × 4-core) along with providing and fixing of new bus bar to supply & fixing of electric connection from the supply systemin main bus bar by MCB ofsize100A, 4-Polebefore
supply&aftersupplyalsoproviding100AMCBonbothsides | 1 | Job | - | - |
| 10 | Electrical Control Panels (Mixed Capacity- 5T × 2 &3T × 2):
10(i) Electric Panel of size 36" × 48" double-door for hoist of 5T capacity—2Nos. &3Tcapacity—2Nos.withbaseframe
10(ii) Fixing of MCB connector, limit switch, wiring etc. for5T capacity—2Nos.&3Tcapacity—2Nos.with MCB25A— 4 Nos., Contractor 25A —4 Nos., Contractor 18A —8 Nos., Contractor15A—8Nos., Contractor9A—8Nos.
10(iii) Remote panel for5Tcapacity—2Nos. ofsize18" × 15" with control of Push Button(i) ON-OFF,(ii) LEFT-RIGHT,(iii) UP-DOWN, (iv) Lengthwise with wire (2.5 sq.mm × 6-core, 1.5 sq.mm×3-core, 1.5sq.mm×6-core, 2.5sq.mm×3-core, 1 sq.mm × 12-core)
10(iv) Wiring of Electric Panel, Motor contractor, MCB for 5T capacity & 3T capacity | 1 | Job | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.04 MB
BOQ_393833.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .