Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹1.8 L
Closing Date
27 Jul 2026, 2:00 pm
Raising of platform at BRPK, BHKA, BGRD, BSLA, MTAP, URP, NCPM, NCP, GOF, HB, BMG, MATL (Total=16 Nos) with cement concreting with all ancillary works under the jurisdiction of Sr. DEN/II/SDAH.
ELEG-OT-1320-2026-27-R
ELEG-OT-1320-2026-27-R
Open
12 Months
Unknown (Unspecified Location)
₹0
₹1.8 L
2 Jul 2026
2 Jul 2026
13 Jul 2026
I-NS Schedule - (Cabling and Wiring Works)
"Trenching and laying of cable underground by soil cutting through suitable dia HDPE pipe (Min Grade: PN-8 1 PE-100), without sand and bricks including refilling of trench by excavated soil and make good of surface as its original condition. (The cable trench should be of minimum 1000 mm depth) (HDPE Pipe Make: Skipper/ Capital Polyplast/ Chaika Polymers/ Utkarsh/ Ashirvad/Arpan/Ori Plast) (L.T. Cable will be supplied by Railway)"
Cable laying through 2" dia. GI Pipe along with supply of GI Pipe as per General Specification. (G.I. Pipe Make: TATA/ Jindal / Bansal ) (L.T. Cable will be supplied by Railway).
Drawing of L.T. cable through PF wall / Structure by cleating / clamping etc as per General Specification. (L.T. Cable will be supplied by Railway)
"Drawing of LT cable in Concealed way through PF wall / structure / building wall etc. as per General specification. 'L' hook should be provided at approx. every half meter length. (L.T.Cable will be supplied by Railway)"
Drawing of LT cable through inside of GI Octagonal / Tubular pole for loop in & loop out. as per General Specification. (L.T. Cable will be supplied by Railway)
"Wiring of light point with 1.5 sq.mm PVC copper wire FRLSH through PVC conduit pipe from inside JB with porcelain fuse kit-kat / MCB of rating 16 A to top of G.I Octagonal pole 5.5 mt. long along with copper ECC of size 1.5mm2 as per General specification of IE Rule. (PVC Wire Make: Havells/ Gloster/ Polycab/ RR Kabel/ KEI/Mescab)"
"Wiring/rewiring of Light and Fan points with 1.5 sq.mm., PVC insulated 1100V grade FRLSH single core, 7 M/Strand copper wire through suitable size (ISI marked) PVC conduit pipe/casing/concealed way along with ECC of 1no. 1.5 sq.mm. , PVC insulated single core, M/Strand FRLSH copper wire as per General specification of IE Rule. (PVC wire Make: Havells/Gloster/Polycab/RR Kabel/KEI/Mescab) (Switch & Plug Socket Make: Panasonic/ Anchor/ GM Modular/ Legrand/Crabtree/ Havells/Hager)"
"Wiring/rewiring of 6 Amp plug board consisting with one 6A plug socket and one 6 amp switch by 2 nos. single core FRLSH grade, PVC insulated, copper conductor wire of size 1.5 mm2, 1100V grade for phase and neutral 8 alongwith 1 no. single core FRLSH grade, PVC insulated, copper conductor wire of size 1.5 mm2, 1100V grade for Earth Continuty Conductor (ECC) through suitable size (ISI marked) PVC conduit pipe/casing/ concealed way. (PVC wire Make: Havells/Gloster/Polycab/RR Kabel/KEI/Mescab) (Switch & Plug Socket Make: Panasonic/ Anchor/ GM Modular/ Legrand/Crabtree/ Havells/Hager)"
"Wiring/Re-wiring of 16 Amp./ 6 pin plug board consisting with one 16A plug socket and one 16 amp switch by 2 nos. single core FRLSH grade, PVC insulated, copper conductor wire of size 4 mm2, 1100V grade for phase and neutral 9 alongwith 1 no. single core FRLSH grade, PVC insulated, copper conductor wire of size 2.5 mm2, 1100V grade for Earth Continuty Conductor (ECC) through suitable size (ISI marked) PVC conduit pipe/casing/ concealed way. (PVC wire Make: Havells/Gloster/Polycab/RR Kabel/KEI/Mescab) (Switch & Plug Socket Make: Panasonic/ Anchor/ GM Modular/ Legrand/Crabtree/ Havells/Hager)"
"Supply and fixing of 3 pin, 5 amp, ceiling rose on the supplied metal box of size (75 mm x 75mm x 60 mm deep) on surface or in recess with suitable size of phenolic laminated sheet cover in front, painting etc. as required including electrical connection for Light & Fan points with 2 nos. 1.5 sq.mm, 1100V grade Copper PVC FRLSH, Single core, Multi-strand wire(for phase and neutral) along with 1 no. single core FRLSH PVC insulated copper wire of size 1.5 sq.mm, 1100V grade for ECC through flexible PVC conduit from ceiling rose connected with Sub-main as per General Specification of I.E. Rule.. (PVC wire Make: Havells/Gloster/Polycab/RR Kabel/KEI/Mescab)"
"Supply and fixing of 3 pin, 5 amp, ceiling rose on the supplied metal box of size (75 mm x 75mm x 60 mm deep) on surface or in recess with suitable size of phenolic laminated sheet cover in front, painting etc. as required including 11 electrical connection for Light & Fan points with 2 nos. 2.5 sq.mm, 1100V grade Copper PVC FRLSH, Single core, Multi-strand wire(for phase and neutral) along with 1 no. single core FRLSH PVC insulated copper wire of size 1.5 sq.mm, 1100V grade for ECC through flexible PVC conduit from ceiling rose connected with Sub-main as per General Specification of I.E. Rule... (PVC wire Make: Havells/Gloster/Polycab/RR Kabel/KEI/Mescab)"
Supply, laying, and termination of sub-main wiring comprising 2 run of 2.5mm² single-core copper conductor 12 PVC FRLSH insulated wires, along with one run of 1.5mm² copper Earth Continuity Conductor (ECC), through suitable size (ISI marked) PVC conduit pipe/casing/ concealed way as per General Specification of I.E. Rule. (PVC wire Make: Havells/Gloster/Polycab/RR Kabel/KEI/Mescab)
"Supply, laying, and termination of sub-main wiring comprising 2 run of 4mm² single-core copper conductor 13 PVC FRLSH insulated wires, along with one run of 2.5mm² copper Earth Continuity Conductor (ECC), through G.I. conduit pipe, for PF shed etc. as per General Specification of I.E. Rule.. (PVC wire Make: Havells/Gloster/Polycab/RR Kabel/KEI/Mescab)"
"Supply, laying, and termination of sub-main wiring comprising 3 run of 4mm² single-core copper conductor 14 PVC FRLSH insulated wires, along with one run of 2.5mm² copper Earth Continuity Conductor (ECC), through G.I. conduit pipe, for PF shed/Car Shed/Shed of FOB etc. as per General Specification of I.E. Rule.. (PVC wire Make: Havells/Gloster/Polycab/RR Kabel/KEI/Mescab)" Unit
II-NS Schedule - (LED Luminaries) (LED luminaries should cover a warranty of 60 (sixty) Above/
"Design of mounting layout ,Supply, installation for LED street light luminaires of approximately 60W rating, 1 having a minimum luminous efficacy of 120lm/W as per General Specification. The luminaires shall be housed in pressure die-cast aluminium enclosures and conform to minimum IP65 protection rating or higher. Installation/fixing of street light fitting should be made with existing/supplied arm bracket of G.I. pole / Rail pole. (Make - Bajaj/ Philips/ Havells/ Crompton/ Panasonic/ Orient/ Signify/Ecolink) "
"Design of mounting layout ,Supply, installation for LED street light luminaires of approximately 90W rating, 2 having a minimum luminous efficacy of 120lm/W as per General Specification. The luminaires shall be housed in pressure die-cast aluminium enclosures and conform to minimum IP65 protection rating or higher. Installation/fixing of street light fitting should be made with existing/supplied arm bracket of G.I. pole / Rail pole. (Make - Bajaj/ Philips/ Havells/ Crompton/ Panasonic/ Orient/ Signify/Ecolink) "
"Design of mounting layout, supply, connection, fixing, testing, and commissioning of integrated LED trunking light fixtures, 40W, 4-ft (1200 mm) length, with linear extruded aluminium housing, sturdiness & excellent 3 corresion resistance powder coated, LED chip efficacy >140 lm/W, Polycarbonate Diffuser, IP>54 luminaire, BuiltIn industrial grade Constant Current electronic LED driver as per General Specification, suitable for Seamless surface or suspended mounting includes all required accessories and suitable installation arrangement for complete functional deployment. (Make - Bajaj/ Philips/ Havells/ Crompton/ Panasonic/ Orient/ Signify/Ecolink) " Unit Above/
III-NS Schedule - (General Electrical Works)
Supply and fixing of GI fabricated cable end box, 4 way as per Sr. DEE (G)/SDAH's Drg. No. SDAH/G/MISC/40 dt. 10.12.07.
"Supply and Fixing of thermoplastic fabricated cable end box, 4 way. As per Sr. DEE/G/SDAH's Drg no.- SDAH/G/4/2024, Dt.- 13.09.2024. Scale: N.T.S (Enclosure Make- CAPE/ Grasp/ Hensel/ Legrand)"
"Supply, concrete foundation & erection of GI Octagonal Pole 5.5mtr. Pole section bottom dia 150mm, top 3 dia 75mm, pole thickness-3mm with base plate 240 x 240x16mm with 4nos. foundation bolts having 25mm dia & of length 700mm along with single/double arm bracket as per General Specification. Loop in & loop out box to be provided inside the pole. Foundation and erection of G.I octagonal pole along with grouting of supplied 4 nos. foundation bolts as per Drg. No. Sr. DEE(G)'s Drg. No. SDAH/G/SS/115 dt. 23.10.09. (Make- B. P. Project/Transrail/ Crompton/ Bajaj/ Utkarsh)"
Concrete muffing of existing Tubular / Rail pole with provision of Thermoplastic cable junction box (IP:65) with terminals including MCB SP,6A,B/Cap:10KA-2 nos.(Dimension of JB=200X160X98mm) (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ C&S/ Havells/Legrand/ Hager)
Dismantling of existing Tubular pole / Rail Pole / octagonal pole and concrete foundation , erection of G.I Octagonal Pole along with grouting of supplied 04 Nos. foundation bolts as per Drg. No.- Sr.DEE(G)'s Drg. No. SDAH/G/SS/115 dt. 23.10.09.
"Supply & fixing of 16A MCB protected socket with sheet steel enclosure. MCB rating taken 6A-16A. (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ C&S/ Havells/Legrand/ Hager) (Switch & Plug Socket Make: Panasonic/ Anchor/ GM Modular/ Legrand/Crabtree/ Havells/Hager)"
"Supply, installation, testing, and commissioning of single-phase 8-way MCB distribution board (surface/concealed mounting type), comprising the following components: a) 1 No. Double Pole MCB, 32A, 10kA breaking 7 capacity (incoming) b) 6 Nos. Single Pole MCB, 10A, 10kA breaking capacity (outgoing) Work shall include complete incoming and outgoing wiring terminations, provision of all necessary mounting hardware, accessories, and interconnections, executed as per site conditions and in compliance with IS/IEC standards (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ C&S/ Havells/Legrand/ Hager) "
"Supply, fixing, connection & commissioning of junction Box made of 14 SWG GI sheet of size 450 mm x 300 8 mm x 250 mm on AT Mast, consisting with 1 No. MCB DP 63A with G. I. Channel suitable for fixing of MCB, complete with hinged door with locking arrangement. (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ C&S/ Havells/Legrand/ Hager) "
"Supply,fixing,testing and commissioning of light control panel with contactor and electro mechanical timer comprising of the following - 1) MCB 32A, Three pole,10KA,415V,50Hz - 1 No., 2) Timer switch- 2 Nos., 3) Power 9 Contactor,3pole,32A - 2 Nos., 4) Toggle switch 6A - 2 Nos., 5) LED Indicators, Indication R,Y,B - 5 Nos. 6) Enclosure made of 14SWG GI sheet fabrication, Panel paint powder coated colour siemens gray and internal wiring with suitable size copper wire etc. (As per Sr.DEE/G/SDAH's drawing number, SDAH/G/1/2024 Dt. 26.02.2024).Fixing should be done by necessary GI fixture and connection with 70%,30% lighting circuit. (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ C&S/ Havells/Legrand/ Hager) "
"Supply, Fixing by necessary GI fixtures, connection and commissioning of Multi mobile charging point board made of 12mm ply and sunmica size 8inchesX15ichesX3inches with wooden tray for resting mobile phones consisting of 4 10 nos. piano type switch 6A,4nos 2-in-1 socket 6A,01 n o LED indicator,01 n o M C B S P 10A including internal wiring with 1.5sq.mm copper wire. (PVC wire Make: Havells/Gloster/Polycab/RR Kabel/KEI/Mescab) (Switch & Plug Socket Make: Panasonic/ Anchor/ GM Modular/ Legrand/Crabtree/ Havells/Hager)(Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ C&S/ Havells/Legrand/ Hager) "
Design, supply, installation, testing & commissioning of automatic 3 point source supply Change over Panel complete for CLS system of Cap. 60 Amp., 240 V, 50 C/S, A.C. as per RDSO's specification No. TI/SPC/PSI/CLS/0020 or latest with suitable clamping arrangement.
Design, supply, installation, testing & commissioning of control & distribution Panel for colour light signaling of rating 30A, 1ph, 240V, 50Hz in 25KV AC traction system as per RDSO's specification No. TI/SPC/PSI/CLS/0020 or latest with suitable clamping arrangement.
Dismantling of existing old damaged wiring and handing over to consignee store.
Supply and installation of G.I. strip of size 25 mm x 3 mm (thick), fixed along walls by grouting suitable size 14 bolts with nuts at 450 mm intervals for earthing, including provision of necessary connections. The G.I. strip shall be separated from the wall using suitable size insulators with the bolts. The work shall be completed with testing and commissioning, strictly in accordance with relevant IS codes, electrical safety standards.
"Supply and installation of GI Standard Earth pipe, 40 mm dia, 2000 mm long, medium gauge complete with 15 provision of Earth pit and there connection with 4 SWG GI wire complete with testing and commissioning, strictly in accordance with relevant IS codes, electrical safety standards.as per Sr. DEE(G)/SDAH's Drg. No. SDAH/G/MISC/47 dt.21.11.2008(Alt-1). (G.I. Pipe Make: TATA/ Jindal / Bansal )"
Dismantling of existing damaged Rail Pole/Tubular Pole. Rail Pole/Tubular Pole to be cut by Gas cutter from the least bottom level. Released Rail Pole to be stacked in an isolated area apart from platform. Released Tubular Pole to be deposited to the custody of concerned Sr. SEE (G) by the Firm. Exposed Cables to be cleared or buried in to the ground
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
FormatofGuaranteeBond.pdf
ATTACHMENT
2022_CE-I_CT_GCC-2022Policy14_07_20221.pdf
ATTACHMENT
GCC-April-2022.pdf
ATTACHMENT
LTHTElectricalBooklet.pdf
ATTACHMENT
LEDluminariesSpecifications_2.pdf
ATTACHMENT
2026_03_13IndianRailwaysStandardGeneralConditionsofContractApril2022AdvanceCorrectionSlipNo_111.pdf Correction
ATTACHMENT
OpenTenderDocument.pdf
ATTACHMENT
Advance
ATTACHMENT
2025_01_09IIndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_9ACS-9.pdf
ATTACHMENT
2026_03_13IndianRailwaysStandardGeneralConditionsofContractApril2022AdvanceCorrectionSlipNo_111.pdf
ATTACHMENT
Download all tender documents and submit your bid