Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.9 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹38.4 L+₹2.8 L (7.90%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹40.5 L+₹4.9 L (13.8%)Rejected-Finance H NO 411 SECTOR 4 CHANNI HIMMAT JAMMU 180015 J K | JAMMU | JAMMU | J K | 180015 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹48.5 L+₹13.0 L (36.4%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹43.9 L
EMD Value
₹87,900
Closing Date
29 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 865 EWS
GE 865 EWS, PIN-913 865 C/o 56 APO
SR TO OR LINE BLDG NO TO 321 SR TO OR TOILET BLDG NO P 105B AND P 105C OF 360 ASC SUPPLY TYPE G SR TO BLDG NO TA 210 AND TA 212 OF 3 INF DOU UNDER GE 865 EWS AT LEH
2022_MES_559802_1
865/EWS(NIT-82)/2022-23
Open Tender
Civil Works
Item Rate
270 days
GE 865 EWS
As per tender documents and as per policy in vogue
9 documents required · 9 mandatory
₹500
GE 865 EWS
₹87,900
Yes
23 Dec 2022
26 Oct 2022
7 Dec 2022
26 Oct 2022
29 Nov 2022
14 Nov 2022
Amount
Demolition of un reinforced cement concret as in ground floor of any description and in any position not other wise specifically provided for and Removing demolished material to a distance and depositing out site of MoD land Where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed by Engineer-in-Charge.
Demolition of un reinforced cement concret in position of any description and in any position not other wise specifically provided for and Removing demolished material to a distance and depositing out site of MoD land Where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed by Engineer-in-Charge.
Demolition of reinforced cement concret as in ground floor of any description and in any position not other wise specifically provided for and Removing demolished material to a distance and depositing out site of MoD land Where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tile to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
Dismantling wall/floor and ceiling boards (fiber, pulp, inlsulation, blankets) any thickness including covered fillets and supporting members complete all as specified and as directed
Dismantling timber scantling in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section as in framed work complete all as specified and directed.
Demolition of precast concrete block/Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
Taking down cement or cement lime plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, including cutting of trees, shrubs or any type of vegitation upto and including roots complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt), complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt), complete all as specified and directed by Engineer-in-Charge.
Hacking out old broken glass (any thick ness, size, quality or description) from wooden panes or stone, concrete or brick surrounds, glazed with oil putty or fixed with beads complete all as specified and as directed by Engr-in-Charge.
Dismantling plain or corrugated steel /fibre sheeting any guage thickness including nanital or similar pattern complete all as specified and as directed by Engr-in-Charge.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed by Engr-in-Charge.
M&L for 9mm thick prelaminated particle board, medium interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed to walls of any description or timper scantling with screws to timber frame work, complete all as specified and as directed by Engr-in-Charge. MAKE: NOVA PAN/GREEN PLY BHUTAN BOARD/MYSORE WOOD BOARD/CENTURY PLYWOOD
M&L for 9mm thick prelaminated particle board, medium interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed to ceilings of any description or timper scantling with screws to timber frame work, complete all as specified and as directed by Engr-in-Charge. MAKE: NOVA PAN/GREEN PLY BHUTAN BOARD/MYSORE WOOD BOARD/CENTURY PLYWOOD
M&L for second class soft wood clean swan as in battens for grids of ceiling and lining, plain fillets exc 13 sqcm and n.exc 25 sqcm, square/ rectangular in section, secured with nails or brads to timber frame work as in fillets, rails, posts, rafters, purlins, grids for ceiling & wall panelling complete all as directed by Engr-in-Charge.
M&L for 2nd class soft wood clean sawn as in beeding for edges of Ceiling ,lining ,or wooden flooring work fixed with nails exc 6 sqcm and n exc 13 sqcm in section.complete all as specified and as directed.
M&L for 75mm thick PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in plinth protection and finished concrete surface even and smooth without using extra cement including making proper joints as per specification at an interval of 3m and change of direction complete all as specified and as directed by Engr-in-Charge.
M&L forming contraction (Dummy) joints 50 mm deep x 10mm wide for plinth protection & similar work , filled with sealing compound Grade 'A' in plinth protection complete all as specified and directed by Engr-in-Charge.
M&L for Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregates as in sub base, foundation, filling and mass concrete, complete all as specified and as directed by Engineer-in-Charge.
M&L pre-cast cement concrete(20mm graded crushed stone aggregate) 1:3:6 type C-1 as in block masonery exc 10cm in width with solid block masonery with solid blocks,exc.10cm in width and setting in cement mortar 1:6 all as Specified by Engr-in-Charge.
M&L for rendering 10 mm thick rendering in cement mortar 1:6 on fair faces of brick walls or on concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge.
M&L for rendering 10 mm thick rendering in cement mortar 1:4 on fair faces of brick walls or on concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed by Engr-in-Charge.
S&F Powder coated (minimum thickness of powder coating 50 micron) anodised aluminium door shutters, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading screws etc. complete all as specified and directed by Engr-in-Charge.
S&F Powder coated (minimum thickness of powder coating 50 micron) anodised aluminium window and ventilator shutters,including aluminium jali of 10 mm thick design/pattern as approved and side hung type without sash,aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading screws, anodised aluminium fittings such as peg stays 150mm long (1 Nos) hinges type B-21 100mm long (2 Nos) suitable handle (1 Nos) etc. complete all as specified and directed By Engr-in-Charge.
S&F Powder coated (minimum thickness of powder coating 50 micron) anodised aluminium window and ventilator shutters, fixed type without sash,aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading screws, anodised aluminium fittings complete all as specified
S&F Pressed steel frames of size 105 mmx60 mm x 1 mm thick MS sheet for doors with one or more rebates including necessary fixings lugs,excluding hinges,lock strike plate,etc,complete ,as specified and directed by Engr-in-Charge. Make as per PS.
M&L for welding in repairs exc 2.5 cm but not exc 5cm in length not exc 6mm thick metal complete as specified by Engr-in-charge
M&L for plain sheet glass 3mm thick ordinalry quality and glazing with oil putty or wooden beads in square not exc 0.50 sqm in each pane complete all as specified and as directed by Engr-in-Charge.
S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples, fixed in repairs complete all as specified and as directed by Engr-in-Charge.
M&L for sheet glass 5.5mm thick ordinalry quality and glazing with oil putty or wooden beads in square not exc 0.50 sqm in each pane complete all as specified and as directed.
S&F for Aluminum, anodized, barrel tower bolts, ISI Marked, of extruded section 150 mm long, complete all as specified and directed by Engr-in-Charge.
S&F for Aluminum, anodized, barrel tower bolts, ISI Marked, of extruded section 100 mm long, complete all as specified and directed by Engr-in-Charge.
S&F 150mm size extruded aluminium alloy handles, fabricated type, anodized complete all as specified and as directed by Engr-in-Charge.
S&F 100mm size extruded aluminium alloy handles, fabricated type, anodized complete all as specified and as directed by Engr-in-Charge.
S&F in repair Aluminium door closer hydraulically regulated designation No 3 , universal type, suitable for door shrtters of 851 to 1000 mm in width and weight between 61 to 80 kg and fixed compelte all as specified and directed by Engr-in-Charge. Make : As per PS.
S&F in repair double action floor spring hydraulically regulated made up of minium 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and directed by Engr-in-Charge.
S&F floor door stopper (Length of cover plate ) 150mm long aluminium alloy body and tongue anodised with hard drawn steel spring fixed in floor complete all as specified and as directed.
S&F 75mm long aluminium anodized, butt hinges of extruded section complete all as specified and as directed.
S&F 100mm long aluminium anodized, butt hinges of extruded section complete all as specified and as directed.
S&F for 300mm long aluminium alloy, anodized, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolts of extruded section or cast aluminium alloy fixed complete all as specified and as directed by Engr-in-Charge.
M&L for 25mm thick PCC 1:2:4, type B-1 using 20mm graded crushed stone aggregate as in sub base/ levelling course for laying of screed bed complete all as specified by Engr-in-Charge.
M & L for joint free Non-Skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed or bedding layer in Cement Mortar 1:4 for laying floor finishes complete all as specified and directed. MAKE: KAJARIA/H&R JOHNSON/CERA/ NITCO/SOMANY
M&L for 20 mm thick granite stone (any type) (table rubbed and polished) in steps, jambs, pillars, window cills, cooking plateform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite including cutting, etc and screed bed with CM (1:4) 20mm thick laying floor tiles complete all as specified and as directed by Engr-in-Charge.
M&L for 75mm thick PCC 1:4:8 type B 2 (using 40mm graded stone aggregate) as in sub base of floors/ pavings etc complete all as specified and as directed by Engr-in-Charge.
Dismantling water tank of any descritpion exceeding 250 & not exceeding 500 litre and removing to store complete al las specified and directed by Engr-in-Charge.
Rotational moulded polyethylene water storage tank, inner and out white, three layers, ISI marked (cylinderical vertical with closed top) hoisted with threaded cap and fixed in position all as specified in SSR Part-I of Capacity 500 litres each including all accessories (i.e GI nipples, etc), including provn of 20/15mm dia spout for connecting inlet, outlet, overflow and washout pipes, including taking down of old broken water tank complete all as specified and as directed by Engr-in-Charge.Make as per PS.
S&F in 25 mm bore, fancy type Stop valve/cock, cast copper alloy, screwed down, high pressure with handle, chromium plated, screwed end for iron pipe or for union and fixed, complete all as specified by Engr-in-Charge.
S&F 25 mm bore ball brass valve high pressure with polythene float and fly nuts complete screwed for iron pipe or brass ferrule complete all as specified and directed by Engr-in-Charge.
S&F in 15mm bore, chromimum plated brass, Bib tap screwed for iron pipe and fixed complete all as specified and as directed by Engineer-in-Charge.
Taking up or down 15 mm bore steel tubing and connections and set aside for re-use or removal to store complete all as specified and directed by Engr-in-Charge.
Taking up or down 25/32 mm bore steel tubing and connections and set aside for re-use or removal to store complete all as specified and directed by Engr-in-Charge.
S&F 15 mm bore 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass treaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified. Make : JINDAL/KISAN/SFMC/Supreme/Kanha Plastic Pvt Ltd
S&F 20 mm bore 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass treaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified. Make : JINDAL/KISAN/SFMC/Supreme/Kanha Plastic Pvt Ltd
S&Fin Vitreous china water closet, 'Orissa' pattern, including lime concrete bedding, size 580 x 440 mm white with integral foot rests excluding flushing cistern and flush pipe but including connection to trap, anti syphonage pipe etc. complete fixed in repairs, incl bedding with PCC 1:2:4 type B-1 using 20 mm grade stone aggregate complete all as specified and as directed by Engr-in-Charge. Make: Cera/Hindware/Parryware
S&F 10 ltr capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with twin flush provision, complete, all as specified and as directed by Engr-in-Charge. MAKE: Cera Model Combiflush twin flush as per Cat Part No. B1020101 (Old Cat Part No 2603) or equivalent in HINDWARE/PARRYWARE
S&F PVC (SWR) 'S’ trap of 125/110 mm bore in setting with PCC 1:2:4, type B1 with 20 mm graded stone aggregate complete all as specified and directed by Engr-in-Charge.
M&L for 110 mm bore, PVC (SWR) pipes, pressure rating 4 kg/sqcm, single or double socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by Engr-in- Charge. MAKE: SUPREME/ASHIRWAD/FINOLEX/ SFMC/ASTRAL
M&L for 110 mm bore, PVC (SWR) pipes, pressure rating 4 kg/sqcm, single or double socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and as directed by Engr-in- Charge. MAKE: SUPREME/ASHIRWAD/FINOLEX/ SFMC/ASTRAL
S&F PVC (SWR) bent 110 mm bore fixed to pipes of any description complete all as specified and directed by Engr-in-Charge.
Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benchng for and forming branch channel (1/2 round or 3/4 round section section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required, 100mm internal dia pipe complete all as specified.
S&F PVC (SWR) vent cowl 110 mm bore fixed to pipes of any description complete all as specified and directed by Engr-in-Charge.
M&L for Cast iron Nahani trap 75mm with grating including jointing to waste pipe fixed in cement concrete type B1 in cement concrete (1:2:4), 20 mm graded stone aggregate complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) bent 75 mm bore fixed to pipes of any description complete all as specified and directed by Engr-in-Charge.
M&L for 75 mm bore, PVC (SWR) pipes, pressure rating 4 kg/sqcm, single or double socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by Engr-in- Charge. MAKE: SUPREME/ASHIRWAD/FINOLEX/ SFMC/ASTRAL
Material and labour for Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 for 110 mm bore pipes including complete all as specified and directed by Engr-in-Charge.
S&F in 15mm bore, chromimum plated brass, Bib tap screwed for iron pipe and fixed complete all as specified and as directed by Engineer-in-Charge. MAKE: PARKO/MARC/ESS ESS/CERA
S&F 15 mm bore chromium plated, fancy type angle valve, cast copper alloy, screwed down, high pressure with handle, chromium plated, screwed end for iron pipe or for union and fixed, suitable for complete all as specified by Engr-in-Charge. MAKE: PARKO/MARC/ESS ESS/CERA
S&F PVC connections 15 mm size with PTMT nuts of length 600 mm, long complete all as specified and diected by Engr-in-Charge. Make: Prayag/Polytuf/Supreme
S&F in repair Viterous china wash basin, white flat back size 580x 450mm including waste coupling CP 32mm dia and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1, fixed complete all as specified and as directed by Engr-in-Charge. MAKE: CERA/HINDWARE/PARRYWARE
S&F in repair 15mm bore, piller tap chromimum plated fancy type high pressure with or without letter Hot or cold with long screwed shank and fly nuts screwed for iron pipe and fixed complete all as specified and as directed by Engineer-in-Charge. MAKE: PARYAG/POLYTUF/SUPREME
S & F in repairs 1000 mm long, 32/ 40 mm dia., PVC flexible Waste pipe for sinks / wash hand basins and upto grating holes/traps complete all as specified and directed by Engr-in-Charge.
S & F in repairs, 40mm waste coupling of PTMT for sink and wash hand basin (Half or full threaded ) (Minimum Weight 45 grams) complete all as specified and directed by Engr-in-Charge.
S & F in repairs, 32mm waste coupling of PTMT for sink and wash hand basin (Half or full threaded ) (Minimum Weight - 45 grams) complete all as specified and directed by Engr-in-Charge.
M&L for hard core of broken stone or boulders of gauge n.exc 63 mm deposited, spread and level in layers n. exc. 15 cm thick watered and rammed to true surface complete all as specified and directed by Engr-in-Charge.
M&L for 100 mm thick PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in floor laid in panels with glass dividing strips finished even and fair with out using extra cement complete all as directed by Engr-in-charge.(Note :- glass dividing strips measured and paid separately)
M&L for 100 mm thick PCC 1:4:8 type B 2 (using 40mm graded stone aggregate) as in sub base of floors/ pavings etc complete all as specified and as directed by Engr-in-Charge.
S&F for Interlocking tiles 60 mm thick of grade M-35 hydrolically pressed pre-PU paint coated in any shape and size confirming to IS 15658-2006 and laying as required pattern complete all as specified and directed by Engr-in-Charge.
M&L for sand filling or spreading and levelling in (50 mm average thickness) as in cushning/bedding etc complete all as specified and directed by Engr-in-Charge.
M&L for 75mm thick PCC 1:4:8 type B 2 (using 40mm graded stone aggregate) as in sub base of floors/ pavings etc complete all as specified and as directed by Engr-in-Charge.
M&L for Chequred cement concrete tiles (glazed) 30cm X 30cm X 20mm thick, set ,pointed & jointed in neat cement slurry in floors polished with grey cement & pigments .Layed over 20mm thick cement screed base (1:6) and all as directed by Engr-in - charge.
S&F MS Rolled sections in main and cross beams,hip and jack rafters ;purlins where connected to common rafters running rails and guids for sliding doors ;fixed with angle cleats or other connecting plates and similar work confirming to Fe-290, Gde-E-165 complete all as specified and as directed by Engr-in-Charge.
Prepainted colored trapezoidal profiled/corrugated Galvalume/ Zinc coated steel sheet with min 0.50mm TCT confirming to IS-513 (AZ-150 GSM, AL Zn alloy mettalic coating 550 MPA yield stress as per AS-1397), as in roof covering/cladding to wall fixed with self tapping screws colour/exterior coat of silicon modified polyster/BHP x RW paint system 20 micron top coat applied over 5 micron top coat applied over 5 micron primer and a 5 micron polyster back coat applied over 5 micron primer, all fixed with Galvanised self drilling/self-tapping fastener (12-14 x 55 with EPDM seals) indlucing dismantling palin or corrugated sheeting any gauge thickness including nanital or similar pattern complete all as specified and directed by Engr-in-Charge Make : Tata Blue Scope Steel Ltd/JSW Steel Ltd/CRIL
Ditto all as item No. 86 (Galvalume sheet) above but except sheeting any thickness complete all as specified and directed by Engr-in-Charge.
Prepainted colored plained Galvalume/Zinc coated steel sheet with min 0.50mm TCT confirming to IS-513 (AZ-150 GSM, AL Zn alloy mettalic coating 550 MPA yield stress as per AS-1397), as in roof covering/cladding to wall fixed with self tapping screws colour/exterior coat of silicon modified polyster/BHP x RW paint system 20 micron top coat applied over 5 micron top coat applied over 5 micron primer and a 5 micron polyster back coat applied over 5 micron primer, all fixed with Galvanised self drilling/self-tapping fastener (12-14 x 55 with EPDM seals) indlucing dismantling palin or corrugated sheeting any gauge thickness including nanital or similar pattern complete all as specified and directed by Engr-in-Charge Make : Tata Blue Scope Steel Ltd/JSW Steel Ltd/CRIL
S&F 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lat fixed with L type J type or cranked hook bolts in lieu of screw complete as specified and directed by Engr-in-charge
Ditto all as item No. 89 (Glass fibre transulant corrugated sheet) above but except sheeting any thickness complete all as specified and directed by Engr-in-Charge.
S&F 2mm thick fibre glass acrylic reinforced translucent plain sheeting fixed with screw /rubber beading etc complete as specified and directed by Engr-in-charge
M&L for preperation of new plastered wall surface of any description and applying three coats of white wash complete all as specified and as directed by Engr-in-Charge.
M&L for preperation of old plastered wall surface of any description and applying two coats of white wash complete all as specified and as directed by Engr-in-Charge.
Complete removal of existing surfaces of walls of any description and applying two coats of distempering with oil bound distemper white or any tinted on walls, filling gaps by putty after washing rubbing down and stopping of surfaces of wall, over a coat of primer complete all as specified and directed by Engr-in-charge.
M&L for preperation and removal of old Steel / CGI Sheet surface any description over 10cm in width or girth and applaying two coat of synthetic enamal paint complete all as specified and as directed by Engr-in-Charge.
M&L for preperation and removal of new Steel / CGI Sheet surface any description over 10cm in width or girth and applaying two coat of synthetic enamal paint over a coat or red oxide zine complete all as specified and directed by Engr-in-Charge.
M&L for two coats cement base paint on newly plastered surfaces of wall including preparation of surfaces including curing before and after applying each coat complete all as specified and directed.
M&L for two coats cement base paint on old treated surfaces of wall including preparation of surfaces including curing before and after applying each coat complete all as specified and directed.
S&F Harrison rails, 19mm dia mild steel, chromium plated curtain rods, with brackets, end bulbs, complete all as specified and as directed by Engr-in-Charge.
S&F soap dish chrome finish stainless steel complete all as specified and directed by Engr-in-Charge.
S & F in repair towel rail 600mm long of aluminum 20 mm dia, D type fixed with and including chrominium plated brass screws and wooden/plastic cleats complete all as specified and directed by Engr-in-Charge.
S&F in repairs Vitreous China bowl Urinal, flat back, size of 465x355x265mm white with grating and union for discharge pipe and PTMT waste coupling with waste pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed by Engr-in-Charge.
S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M. S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, suppling & fixing in the frame at site complete all as specified and as directed by Engineer-in-Charge.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed by Engineer-in-Charge.
S&F in repair stain less steel Towel Hanger with 6 Nos of pin and 600mm long fixed to walls/tiles/wooden panels with SS screws with fisher etc as approved etc complete all as sepcified and directed by Engr-in-charge.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/ dense soil , including spreading and levelling in layers n exc 25 cm thick complete all as specified and directed by Engr-in-Charge.
Excavating over areas, n exc 1.5 m deep and getting out hard/dense soil complete all as specified and directed by Engr-in-Charge.
Excavating over areas, exc 1.5 m but not exc 3.00 m deep and getting out hard/dense soil complete all as specified and directed by Engr-in-Charge.
M&L for Walling of random rubble, uncoursed stone masonary, well bonded, laid dry in retaining wall, soakage pit, manholes abutment and similar work complete all specified and as directed by Engr-in-Charge.
M&L for Walling of random rubble, uncoursed stone masonary, well bonded, laid dry in retaining wall, soakage pit, manholes, abutment and similar work built in cement mortar 1.:6 complete all specified and as directed by Engr-in-Charge.
M&L form work to soffits of suspended flat sabs such as roof slabs ,floor slabs,landings and similar works (smooth finished flat surface of cncrete) not exceding 200mm thick (Horrizontal or sloping) complete all as specified and directed by Engr-in-Charge.
M&L form work to fair finshed edges of concreat flats, treads breaks in floors, window cills, concrete failings, openings in concrete walls, floor and roofs n.exe 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20 cm wide complete all as specified and directed by Engr-in-Charge.
M&L RCC type B1 1:2:4 (20 mm grade aggregate ) in Slabs supported on walls ,beams and columns,in floors, roofs,landings, balconies, canopies,deck slabs and in shelves and the like complete all as specified and directed by Engr-in-Charge.
M&L for precast cement concrete Type B1, 1:2:4 (20mm graded aggregate) in landings, cover slabs (for manholes etc), chullah hoods, chhajja, water troughs, shelves and similar articles with plain faces, setting in CM 1:6, complete all as specified and as directed by Engr-in-Charge.
M&L mild steel TMT bars10mm dia and over, cut length, bent to shape required , including cranking , bending spirally for hooping for coloumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to TMT bar complete all as specified and directed by Engr-in-Charge.
Excavating in trenches, n. exc 1.5 m wide and exc 1.5 m and not exc 3.00 m in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. n exc 10 sq m on plan in hard/dense soil and getting out soil, complete all as specified and as directed by Engineer-in-charge.
Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any type of soil complete all as specifed and as directed by Engineer-in-Charge.
Removal of excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specifed and as directed by Engineer-in-Charge.
M&L broken stone for loose filling of guage 80mm to 150 mm graded for soak wells complete all as specified and directed by Engr-in-Charge.
Taking down shutters of any description area exceeding 1 Sqm and not exceeding 2 Sqm each of complete all as specified directed by Engr-in-charge.
Taking down shutters of any description area not exceeding 1 Sqm each of complete all as specified directed by Engr-in-charge.
M&L 6mm (5 ply) thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face, fixed with nails to timber frame work on ceiling complete all as specified and as directed by Engr-in-Charge.
M&L for 15 mm thick rendering using water proofing compound @ 3% of cement on other than fair faces of brick works finished even and smooth without using extra cement in cement mortar 1:6 complete all as specified and as directed by Engr-in-Charge.
Supply only integarl waterproofing compound complete all as specified and directed by Engr-in-Charge.
S&F 2nd class soft wood plain, solid, straight chowkets and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as directed by Engr-in-Charge.
S&F mild steel work as in hold fasts and similar work confirming to Fe-290 or Gd -E 165 complete.all as specified and as directed by Engr-in-Chage
Material & labour PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) as in hold fast , bed block and like complete all as specified and as directed by the Engr-in-Charge.
S&F for 35mm thick 2nd class hard wood plain framed factory made paneled shutters (any number of panels) with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers, Supply and fixed to chowkatscomplete all as directed by Engr-in-charge.Make as per PS.
S&F for 35mm thick 2nd class hard wood plain framed factory made glazed and skeletion shutter shutters , open rebated and prepared to receive glass , gauze etc (without sash bars) edges of framing plain , chamfered or rounded fitted with cut and mitred beds for securing glass etc size of members of shutters as specified in SSR part I, Section 8 , clause 8.24(a) supplied and fitted to chowkats , complete all as specified and directed by Engr-in-charge.Make as per PS.
S&F for 30mm thick 2nd class hard wood plain framed factory made glazed and skeletion window shutters , open rebated and prepared to receive glass , gauze etc (without sash bars) edges of framing plain , chamfered or rounded fitted with cut and mitred beds for securing glass etc size of members of shutters as specified in SSR part I, Section 8 , clause 8.24(a) supplied and fitted to chowkats , complete all as directed by Engr-in-charge.
S&F 75mm size extruded aluminium alloy handles, fabricated type, anodized complete all as specified and as directed by Engr-in-Charge.
M&L Glazed ceramic coloured tiles in vertical surfaces (350 X 250X7mm ) / (450x350x7mm) thick set and jointed in neat cement slurry and pointed in white or colour cement to match the surface over rendering 10mm thick in CM (1:4) , for dado/skirting tiles.complete all as specified and as directed by the Engr-in-charge.
M&L for Non skid coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.06 and nexc .11 sqm in floor etc set and jointed in neat cement slurry and pointed with white or coloured cement mixed with pigments to match the 15mm thick screed bed with CM (1:4) laying floor tiles complete all as specified and directed by Engr-in-Charge.
S&F 25 mm bore 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass treaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified. Make : JINDAL/KISAN/SFMC/Supreme/Kanha Plastic Pvt Ltd
S&F 0.63mm thick Galvanised corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers in roofs walls etc. with grade of zine coating 275 complete all as specified and directed by Engr-in-Charge.
Ditto all as per item No 135 above but except sheeting complete all as specified and directed by Engr-in-Charge.
S&F 0.63mm thick plain galvanised mild steel sheeting as in ridges hip, valley gutters drip and straight flashings (length and girth as fixed) with L or J hooks or coach screws with grade of zinc coating 275 complete all as specified and as directed by Engr-in-Charge.
M&L for preperation of new or previously untreated wooden surface any description of any description over 10cm in width or girth and applaying two coat of synthetic enamal paint over a coat of Pink primer complete all as specified and as directed complete all as specified and as directed by Rngr-in-Charge.
M&L for preperation of old wooden surface surface any description over 10cm in width or girth and applaying one coat of synthetic enamal paint all as specified and as directed complete all as specified and as directed by Engr-in-Charge.
M&L for preperation of new concrete /plastered surface of wall any description including 3mm thick wall care putty applaying two coat of distemper oil emulsion over a coat of primer complete all as specified and as directed complete all as specified and as directed by Engr-in-Charge.
M&L for cleaning of sluge/water from septic tank/ sockage well by manually upto 3.0 m depth and remove to a distance n.exc 50m complete all as specified and directed by Engr-in charge .
M & L for Preparing old plasted surfaces of wall and applying two coats of distemper oil emulsion including with with complete removal of existing treatment on walls complete all as specified and directed by Engr-in-Charge.
M&L for plain sheet glass 4mm thick ordinalry quality and glazing with oil putty or wooden beads in square not exc 0.50 sqm in each pane complete all as specified and as directed by Engr-in-Charge.
S&F in repair Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples, fixed in repairs complete all as specified and as directed by Engr-in-Charge.
Taking down carefully copper/Aluminum point wiring (Light, Fan, Socket or power) complete fitting such as switches, ceiling, regulator, sockets etc removing materials to be store for keeping in safe custody for taking credit and making good disturbed surfaces of walls, floors etc complete all as speciifed and directed by Engr-in-Charge
Taking down of old sub main wirings at any description complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring for one light point or fan point controlled by one light/exhaust fan controlled by one way switch with PVC insulated copper conductor stranded cable of size 1.5 sqmm and including PVC casing/caping terminated in existing sunk CI/pressed steel terminal boxes for fixing and 1.5 sqmm PVC insulated copper wire as earth wire connected to earth wire connected to earth folly and 3.0mm thick plastic laminated sheet cover all as specified and directed by Engr-in-Charge.
All as per item No 147.00 here-in-before but 1.5 Sqmm for one 3 pin 6 amps socket outlet including 1.5 sqmm insulated copper wire as earth wire to the same earth dolly on the same board complete all as specified and directed by Engr-in-Charge.
All as per item No 147.00 here-in-before but 1.5 Sqmm for one 3 pin 6 amps socket outlet including 1.5 sqmm insulated copper wire as earth wire to the same earth dolly on the independent board complete all as specified and directed by Engr-in-Charge.
All as per item No.147 above but using cable 4 Sqmm complete all as specified and directed by Engr-in-Charge
S&F in replacement for lamp holder PVC/Poly corbonate type insulated body with back plate suitable for batten fittings as specified and directed by Engr-in-Charge.
S&F in replacement for switch piano flush type one way single pole 5/6 Amp 240 volts complete all as specified and directed by Engr-inCharge.
S&Fin replacement for switch socket combination 2 in 1, 5 pin, 5/6 Amps flush type universal complete all as specified and directed by Engr-in-Charge.
S&Fin replacement for switch socket combinationmut let mulit purpose 2 in 1, 5 pin, 6 Amps and 16 Amps 230 V flush type universal complete all as specified and directed by Engr-in-Charge.
S&F in replacement for ceiling rose surface bakelite 65x50 mm two to three terminals complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement for MCB distribution board Double door, regal grey, sheet metal enclosure, SPN 240 volts 4 way with 200 amps rated bus bar concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc . Make: Cat part No 5076 11 of Legrand (Ekinoxe) or equal approved in Schneider (Acti-9)/Siemens (Betagard-8GB32) or equivalant make in PS.
Supply and fixing in replacement for MCB distribution board Double door, regal grey, sheet metal enclosure, SPN 240 volts 8 way with 200 amps rated bus bar concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc . Make: Cat part No 5076 11 of Legrand (Ekinoxe) or equal approved in Schneider (Acti-9)/Siemens (Betagard-8GB32) or equivalant make in PS.
Supply and fixing in replacement for MCB SPN 40 Amps, 'C' series, 240 V A/C complete all as specified and as directed by Engineer-in-Charge. Make: Cat part No 4085 96 of Legrand (DX³) or equal approved in Schneider (Acti-9)/ Siemens (Betagard-5SL4)
Supply and fixing in replacement for MCB SPN 63 Amps, 'C' series, 240 V, 10KA, A/C complete all as specified and as directed by Engineer-in-Charge. Make: Cat part No 4085 96 of Legrand (DX³) or equal approved in Schneider (Acti-9)/ Siemens (Betagard-5SL4)
Supply and fixing MCB SPN 6 to 32 Amps, 'C' series, 230 V A/C complete all as specified and as directed by Engineer-in-Charge. Make: Cat part No 4086 09 to 4086 17 of Legrand (DX³) or equal approved in Schneider (Acti -9)/ Siemens (Betagard-5SL4)
Sub main wiring with two run of 6.00 Sqmm (2x6 sqmm) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC casing caping ISI marked with all accessories etc with one run of 6.00 Sqmm (1x6sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire and making good to match with existing surfaces including taking down of old sub main wirings complete all as specified and directed by Engineer-in-Charge. Note:- 2 runs of 6 Sqmm (2x6sqmm), one run of 6 Sqmm (1x6 sqmm) cable and one metre of PVC casing caping will be measured as one unit. Make of cable: L&T/FINOLEX/GRANDPLAY/ANCHOR/ POLYCAB
S&F in replacement for LED lights fitting, TITANIA SLEEK NEW T5 LED TUBELIGHT (DOUBLE SIDE CONNECTION) , 1x20 watt, 220 volts, AC ultra bright LED tube light with aluminium heat sink & polycarbonate diffuser having high efficacy suited for installation in existing T5 fitting with G5 lamp holders, led driver outside decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. Make as per PS.
S&F in replacement for LED lights fitting, TITANIA SLEEK NEW T5 LED TUBELIGHT (DOUBLE SIDE CONNECTION) , 1x10 watt, 220 volts, AC ultra bright LED tube light with aluminium heat sink & polycarbonate diffuser having high efficacy suited for installation in existing T5 fitting with G5 lamp holders, led driver outside decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. Make as per PS.
S&F in replacement for LED bulk head light fitting 1x9/10 watt 230 volt attractive wall/ceiling mounted any type with white reflactor complete with all accessories pre-wired and including connecting up with 3 core twisted flaxible copper conductor cable complete all as directed. Make as per PS.
Supply and fixing of exhaust fan, PVC body, AC single phase 230 volts of size 380 mm sweep with blades and frame and louvers complete all as specified and as directed.
Supply and fixing connecting and testing LED security light fittings 35 watt, AC out door type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp and bracket with impact and corrossion resistant including thermal management in multiple optics coplete wit IP65/66 protection complete all as specified and as directed make as per PS.
S&F in replacement 36 watts QUADRO 2'X2' precisely designed decorative Pmma diffuser 2x2 panel light that unites a creative design with state-of-the-art led technology. the concept of protruded decorative diffusers achieves a great sense of novelty and flexibility with multiple diffuser designs while offering perfect illumination and greater uniformity. this design stands out stunningly among the boring old modular ceiling patterns complete all as specified and directed by Engr-in-Charge. Make : Cat Part No QUADRO2X2PLR36WLED857S of Havells or equivalent in Bajaj/Philips.
Supply & laying or fixing and testing of 1100 volts grade duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape overall PVC sheathed solid conductor in service connections 25 Sqmm four core flat/circular cable complete all as specified and directed by Engr-in-Charge. Make as per PS.
Material and labour for earthing complete with galvanised steel earth plate 600 x 600 x 6 mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level connected to and including GI wire of size 4 mm dia by means of nuts, bolts, washers etc made of and connected to test point and earth dolly as all shown in electrical plate No.3 of SSR Part-I 2009 and specified or indicated including excavation and earth work in any type of soil PCC (1:3:6) type C1 in chamber, pre cast RCC slab 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.0 kg/Sqm) with cast iron frame, funnel, with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore light grade GI protection pipe, test point, etc, incluidng taking down of old u/s earthing set complete all as specified and as directed. Note: (i) Item includes the cost of 7.5 m GI pipe for protection of earth lead. Any additional length shall be adjusted through deviation order. (ii) Item includes the cost of 7.5 m GI earth lead. Any additional in length shall be adjusted through deviation order ( For Main DBs ) (iii) Item includes the cost of Charcoal and commercial salt ( For Main DBs )
SHUBHAM ENGINEERS & BUILDERS
Mehar Enterprises
SATISH KUMAR AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .