Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹77.3 CrAccepted-AOC THIRD FLOOR AMIT CRYSTAL SENAPATI BAPAT ROAD PUNE 411 016 | PUNE | PUNE | MAHARASHTRA | 411016 | ₹77.3 Cr | L1 | Accepted-AOC Accept |
| 2 | L2₹78.8 CrRejected-AOC HARSH ANAND YEVALEKAR MALA COLLEGE ROAD NASHIK 422005 | NASHIK | NASHIK | MAHARASHTRA | 422005 | ₹78.8 Cr | L2 | Rejected-AOC Accept |
Tender Value
₹69.7 Cr
EMD Value
₹34.8 L
Closing Date
27 Sept 2021, 6:30 pmClosed
E.E.P.W.DIVN. NANDED
OFFICE OF THE E.E.P.W.DIVN. NANDED
CONSTRUCTION OF ADMINISTRATIVE COURT BUILDING IN GUT NO. 118, 119 (PART) NECESSARYFOR ADMINISTRATIVE OFFICES AT ASARJAN DIST. NANDED.
2021_PWR_719971_1
PWD/NED/39/2021-22
Open Tender
Civil Works
730 days
NANDED
AS PER TENDER DOCUMENT
4 documents required · 4 mandatory
₹3,000
₹34.8 L
OFFICE OF THE C.E. P.W.REGION, AURANGABAD
7 Mar 2022
13 Sept 2021
28 Sept 2021
13 Sept 2021
27 Sept 2021
13 Sept 2021
20 Sept 2021
Amount
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts and spreading for embankment or stacking as directed. Basement Floor
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material with all leads & lifts beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means Basement Floor
Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material with all leads & lifts beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means Basement Floor
Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 3.00 m to 4.5.0m) By Mechanical Means Basement Floor
Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 4.5m to 6.00 m) By Mechanical Means Basement Floor
Conveying materials obtained from road cutting including all lifts, laying in layers of 20cm to 30cm. breaking clods, dressing to the required lines, curves, grades and section, watering and compacting to not less than 97% of standard Proctor density for a lead of over 50m. to 300m. inclusive from the site of excavation to the site of deposition as directed. Basement Floor
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc.complete. Basement Floor
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. & filling sand in voids Basement Floor
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Basement Floor
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. Basement Floor
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per square metre of vertical surface area covering 10 years guarantee on bond paper. Basement Floor
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. Basement Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for bed blocks foundation blocks and such other items including out water steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided,finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) Basement Floor
Providing and laying in-situ M30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate( VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver,compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-in- charge. Basement Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork,cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. columns Ground floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. columns First Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. columns Second Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. columns Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. columns Fourth Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels Ground floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels First Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels Second Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels Fourth Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings Ground floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings First Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings Second Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings Fourth Floor
Providing and laying Cast in situ/Ready Mixcement concrete M-30 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Ground floor
Providing and laying Cast in situ/Ready Mixcement concrete M-30 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja First Floor
Providing and laying Cast in situ/Ready Mixcement concrete M-30 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja Second Floor
Providing and laying Cast in situ/Ready Mixcement concrete M-30 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja Third Floor
Providing and laying Cast in situ/Ready Mixcement concrete M-30 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja Fourth Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite / quartzite / gneiss metal for R.C.C. canopy as per detailed designs and drawings including steel centering, formwork, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing etc. complete (excluding reinforcement). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi Ground floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi First Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi Second Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi Fourth Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap / quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap / quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps Ground floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap / quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps First Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap / quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps Second Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap / quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap / quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps Fourth Floor
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Basement Floor
Providing and fixing in position TMT - FE - 500 bar reinforcement Ground floor
Providing and fixing in position TMT - FE - 500 bar reinforcement First Floor
Providing and fixing in position TMT - FE - 500 bar reinforcement Second Floor
Providing and fixing in position TMT - FE - 500 bar reinforcement Third Floor
Providing and fixing in position TMT - FE - 500 bar reinforcement Fourth Floor
Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. Terrace floor
Providing expansion joints in R.C.C. framed structure (interior column) with plain premoulded filler 25 mm thick including fixing T.W. battens on both faces and finishing as directed etc. Complete. Basement Floor
Providing expansion joints in R.C.C. framed structure (interior column) Ground floor
Providing expansion joints in R.C.C. framed structure (interior column) First Floor
Providing expansion joints in R.C.C. framed structure (interior column) Second Floor
Providing expansion joints in R.C.C. framed structure (interior column) Third Floor
Providing expansion joints in R.C.C. framed structure (interior column) Fourth Floor
Providing expansion joints in R.C.C. framed structure (exterior Columns) with plain premoulded filler 25 mm thick and 3 mm thick alluminium plate, hold fast, fixing T.W. battens on internal face, finishing etc. complete as directed. Basement Floor
Providing expansion joints in R.C.C. framed structure (exterior Columns) Ground floor
Providing expansion joints in R.C.C. framed structure (exterior Columns) First Floor
Providing expansion joints in R.C.C. framed structure (exterior Columns) Second Floor
Providing expansion joints in R.C.C. framed structure (exterior Columns) Third Floor
Providing expansion joints in R.C.C. framed structure (exterior Columns) Fourth Floor
Providing expansion joints in R.C.C. framed structure (at floor level) with premoulded filler 25 mm thick and 3 mm thick aluminium plate as required, bitumen poured filler and fixing T.W. battens on rear faces etc. complete as directed. Basement Floor
Providing expansion joints in R.C.C. framed structure (at floor level) Ground floor
Providing expansion joints in R.C.C. framed structure (at floor level) First Floor
Providing expansion joints in R.C.C. framed structure (at floor level) Second Floor
Providing expansion joints in R.C.C. framed structure (at floor level) Third Floor
Providing expansion joints in R.C.C. framed structure (at terrace level) with premoulded filler 25 mm thick and 3 mm thick aluminium plate as required, bituminous poured filler, fixing lead, flashing on upper side and T.W. battens on inner face finishing etc. Complete as directed. Fourth Floor
Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. Basement Floor
Providing Autoclaved Aerated Concrete Block masonary of Ecolite or equivalent make conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) Basement Floor
Providing Autoclaved Aerated Concrete Block masonary Ground floor
Providing Autoclaved Aerated Concrete Block masonary First Floor
Providing Autoclaved Aerated Concrete Block masonary Second Floor
Providing Autoclaved Aerated Concrete Block masonary Third Floor
Providing Autoclaved Aerated Concrete Block masonary Fourth Floor
Providing Autoclaved Aerated Concrete Block masonary of Ecolite or equivalent make conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) Ground floor
Providing Autoclaved Aerated Concrete Block masonary First Floor
Providing Autoclaved Aerated Concrete Block masonary Second Floor
Providing Autoclaved Aerated Concrete Block masonary Third Floor
Providing Autoclaved Aerated Concrete Block masonary Fourth Floor
Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter / two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc. complete. Ground floor
Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick First Floor
Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick Second Floor
Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick Third Floor
Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick Fourth Floor
Providing & laying water proof treatment of terrace slab with B.B. Coba in all position with an average thickness of 150mm consisting specialised materials as per the manufactures specifications and covering 10 years guarantee on court fee stamp paper including all lead, lift, etc. complete. Fourth Floor
Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. Ground floor
Providing water proof bedding for flooring of Bath and WC First Floor
Providing water proof bedding for flooring of Bath and WC Second Floor
Providing water proof bedding for flooring of Bath and WC Third Floor
Providing water proof bedding for flooring of Bath and WC Fourth Floor
Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittance tested as per ASTM) C 1549 and ASTM C 1371 respectively, VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strctly as per manufacturer's specifitions and as approved by engineer in charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc, washing with water all complete.The contractor shall give guarantee for the performance of SRI and also the durabitity of coating, all complete as per direction of Engineer - in- incharge. Fourth Floor
Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete) Basement Floor
Providing and applying plaster / wall punning with plaster of paris ( with plaster of paris material of Ambuja / Mor Chap or equivalent make ) in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete. Basement Floor
Providing and applying plaster / wall punning with plaster of paris Ground floor
Providing and applying plaster / wall punning with plaster of paris First Floor
Providing and applying plaster / wall punning with plaster of paris Second Floor
Providing and applying plaster / wall punning with plaster of paris Third Floor
Providing and applying plaster / wall punning with plaster of paris Fourth Floor
Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete Basement Floor
Providing internal cement plaster 20mm thick in Single coats Ground floor
Providing internal cement plaster 20mm thick in Single coats First Floor
Providing internal cement plaster 20mm thick in Single coats Second Floor
Providing internal cement plaster 20mm thick in Single coats Third Floor
Providing internal cement plaster 20mm thick in Single coats Fourth Floor
Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. RCC pardi/ Wall and all type of Interior, Exterior Compound wall and Gate etc. of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, GFRC admixtures, Colour pigments, Fiber up to thick of 230 mm/ 25 mm including scaffolding, fixing of screw, etc. (As directed by Engineer in Charge) Basement Floor
Providing and Fixing Processed Stone Cladding on wall surface Ground floor
Providing and Fixing Processed Stone Cladding on wall surface First Floor
Providing and fixing GRC/FRP decorative emblem with details as per drawing with the state emblem and carvings as shown in 3 dimesion upto a thickness of 150 mm with scroll designs, floral designs, dentals, flutings etc., Item to include checking all surfaces for proper line and level, scaffolding etc. complete. Item includes preparing upto 5 samples for the Architects approval. Item to include making of the clay model and mould for the decorative cornice and supply of the decorative cornice as per approved sample executed in fiber glass material Basement Floor
Providing and fixing GRC/FRP decorative emblem with details as per drawing Ground floor
Providing and fixing GRC/FRP decorative emblem with details as per drawing First Floor
Providing and fixing GRC/FRP decorative emblem with details as per drawing Second Floor
Providing and fixing GRC/FRP decorative emblem with details as per drawing Third Floor
Providing and fixing GRC/FRP decorative emblem with details as per drawing Fourth Floor
Providing and fixing GRC/FRP decorative curved festoon or garland with details as per drawing with carvings as shown in 3 dimesion upto a thickness of 150 mm with scroll designs, floral designs, dentals, flutings etc., Item to include checking all surfaces for proper line and level, scaffolding etc. complete. Item includes preparing upto 5 samples for the Architects approval. Item to include making of the clay model and mould for the decorative cornice and supply of the decorative cornice as per approved sample executed in fiber glass material Basement Floor
Providing and fixing GRC/FRP decorative curved festoon or garland with details Ground floor
Providing and fixing GRC/FRP decorative curved festoon or garland with details First Floor
Providing and fixing GRC/FRP decorative curved festoon or garland with details Second Floor
Providing and fixing GRC/FRP decorative curved festoon or garland with details Third Floor
Providing and fixing GRC/FRP decorative curved festoon or garland with details Fourth Floor
Providing and fixing GRC/FRP Medallions to be made in CNC cut GRC Jali of different sizes circular or elliptical as shown in the drawing or indicated by the Architect as mentioned below with all profiling. Item includes preparing upto 5 samples for the Architects approval. Item to include making of the clay model and mould for the decorative cornice and supply of the decorative cornice as per approved sample executed in fiber glass material Basement Floor
Providing and fixing GRC/FRP Medallions to be made in CNC cut GRC Jali Ground floor
Providing and fixing GRC/FRP Medallions to be made in CNC cut GRC Jali First Floor
Providing and fixing GRC/FRP Medallions to be made in CNC cut GRC Jali Second Floor
Providing and fixing GRC/FRP Medallions to be made in CNC cut GRC Jali Third Floor
Providing and fixing GRC/FRP Medallions to be made in CNC cut GRC Jali Fourth Floor
Providing and fixing in position factory made precast Glass fiber reinforced concrete (GRC) as per approved manufactures specification and as per approved drawings. The thickness of GRC panel should Nost be less than 20mm with minimum 20mm thick GRC pads acting as stiffeners. Colour and texture should be approved by Engineer in charge. Fixing of GRC panel on primary structure shall be done by fry cladding method with the help of SS screw fixtures, MS angle cleats, fissures plug and Dowel pin etc. in proper aligment, line and level as per the approved drawing, Finishing with GRC powder filling the joints with paintable silicon sealant neatly between GRC panel and primary structure to provide one piece look including molding and cornice at junction of column and beamsas per approved drawings, including necessary MS fabrication work to support GRC structure, necessary scaffolding at all levels and staging etc. (Nosn SSR Item) Basement Floor
Providing and fixing in position factory made precast Glass fiber reinforced concrete (GRC) Ground floor
Providing and fixing in position factory made precast Glass fiber reinforced concrete (GRC) First Floor
Providing and fixing in position factory made precast Glass fiber reinforced concrete (GRC) Second Floor
Providing and fixing in position factory made precast Glass fiber reinforced concrete (GRC) Third Floor
Providing and fixing in position factory made precast Glass fiber reinforced concrete (GRC) Fourth Floor
Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details of various heights as mentioned below including grooves in wall, opening side vertical band, architraves, lintels etc. complete as per original detailing including scroll designs, floral designs, dentals, flutings etc., Item to include checking all surfaces for proper line and level, scaffolding etc. complete. Item includes preparing upto 5 samples for the Architects approval. Item to include making of the clay model and mould for the decorative cornice and supply of the decorative cornice as per approved sample executed in fiber glass material Ground floor
Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details First Floor
Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details Second Floor
Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details Third Floor
Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details Fourth Floor
Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details of various heights as mentioned below including grooves in wall, opening side vertical band, architraves, lintels etc. complete as per original detailing including scroll designs, floral designs, dentals, flutings etc., Item to include checking all surfaces for proper line and level, scaffolding etc. complete. Item includes preparing upto 5 samples for the Architects approval. Item to include making of the clay model and mould for the decorative cornice and supply of the decorative cornice as per approved sample executed in fiber glass material Ground floor
Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details First Floor
Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details Second Floor
Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details Third Floor
Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details Fourth Floor
Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details of various heights as mentioned below including grooves in wall, opening side vertical band, architraves, lintels etc. complete as per original detailing including scroll designs, floral designs, dentals, flutings etc., Item to include checking all surfaces for proper line and level, scaffolding etc. complete. Item includes preparing upto 5 samples for the Architects approval. Item to include making of the clay model and mould for the decorative cornice and supply of the decorative cornice as per approved sample executed in fiber glass material Ground floor
Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details First Floor
Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details Second Floor
Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details Third Floor
Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details Fourth Floor
Providing and fixing GRC panels/freize as per design to be fitted on walls, or above doors as indicated by the Architect. Painting of the ceiling to be paid as per relevant Item. The design of the panel to include mouldings on the edge, designs within the mouldings varying from any shape or size within the outer edge as shown in the drawign and the entire area to be detailed and made in profile with mouldings, dentals, fluting, floral details, bosses, etc., Item includes preparing upto 5 samples for the Architects approval. Item to include making of the clay model and mould for the decorative cornice and supply of the decorative cornice as per approved sample executed in fiber glass material Mode of Measurement: the entire area of the panel/freize to be paid in area from out to out of the moulding edge. Nosthing extra to be charged for details or designs which are part of the false ceilign design under aNosther item. Basement Floor
Providing and fixing GRC panels/freize as per design to be fitted on walls, or above doors Ground floor
Providing and fixing GRC panels/freize as per design to be fitted on walls, or above doors First Floor
Providing and fixing GRC panels/freize as per design to be fitted on walls, or above doors Second Floor
Providing and fixing GRC panels/freize as per design to be fitted on walls, or above doors Third Floor
Providing and fixing GRC panels/freize as per design to be fitted on walls, or above doors Fourth Floor
Providing & Fixing in position, Acoustical Panelling made from 12mm wp Ply wood & 1.5mm laminate on, 50 x 50 mm Sal-wood frame of 600 x 600 c to c having wooden supports from wall of required length, in front of 1000 Gsm synthetic wool 50 mm thick with chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings / finishing-items / paint & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects.including all materials labour,finishing etc complete First floor
Providing & Fixing in position, Acoustical Panelling Second Floor
Providing & Fixing in position, Acoustical Panelling Third Floor
Providing & Fixing in position, Acoustical Panelling Fourth Floor
Providing & Fixing in position, Acoustical Panelling made from Fabric wrapped Compressed polyester fibre nonwoven 9 mm panels on, 50 x 50 mm sal-wood frame of 600 x 600 c to c having wooden supports from wall of required length, in front of 1000 gsm synthetic wool 50 mm thick with chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings / finishing-items / paint & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects.including all materials labour,finishing etc complete First Floor
Providing & Fixing in position, Acoustical Panelling Second Floor
Providing & Fixing in position, Acoustical Panelling Third Floor
Providing & Fixing in position, Acoustical Panelling Fourth Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Second floor
Providing sand faced plaster externally Third Floor
Providing sand faced plaster externally Fourth Floor
Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete. Basement Floor
Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete. Basement Floor
Providing patti/ band 75mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete. Ground Floor
Providing patti/ band 75mm wide on plastered surface First Floor
Providing patti/ band 75mm wide on plastered surface Second Floor
Providing patti/ band 75mm wide on plastered surface Third Floor
Providing patti/ band 75mm wide on plastered surface Fourth Floor
Providing patti/ band 100mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete. Ground floor
Providing patti/ band 100mm wide on plastered surface First Floor
Providing patti/ band 100mm wide on plastered surface Second Floor
Providing patti/ band 100mm wide on plastered surface Third Floor
Providing patti/ band 100mm wide on plastered surface Fourth Floor
Providing patti/ band 150mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete. Ground Floor
Providing patti/ band 150mm wide on plastered surface First Floor
Providing patti/ band 150mm wide on plastered surface Second Floor
Providing patti/ band 150mm wide on plastered surface Third Floor
Providing patti/ band 150mm wide on plastered surface Fourth Floor
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / B.B .masonry and or tying by binding wire etc. complete. Basement Floor
Providing and fixing chicken mesh of 22 gauge Ground floor
Providing and fixing chicken mesh of 22 gauge First Floor
Providing and fixing chicken mesh of 22 gauge Second Floor
Providing and fixing chicken mesh of 22 gauge Third Floor
Providing and fixing chicken mesh of 22 gauge Fourth Floor
Providing and applying plaster with plaster of paris in 6mm thickness to previously plaster surface in all position including preparing the surface scaffolding etc. complete.
Providing and applying plaster with plaster of paris Ground floor
Providing and applying plaster with plaster of paris First Floor
Providing and applying plaster with plaster of paris Second Floor
Providing and applying plaster with plaster of paris Third Floor
Providing and applying plaster with plaster of paris Fourth Floor
Providing and fixing false ceiling with eco-friendly light-weight calcium silicate tiles of spintone surface texture aerolite make or equivalent of size 595mm x 595mm having 15mm thick densified micro look edge and 100% humidity resistance incombustible as per BS 46part IV and thermal conductivity 0.043 w/m 0 KC and NRC 0.50 placed in true horizontal level suspended grid of size 600x600mm made from hot dipped G.I. steel sections ion silhouette profile, rotary stitched double webbed white with 6mm reveal profile (white/black), wherein, main T runner of size 42mmx14mm between main tee 600mm center-tocenter and secondary cross T of size 33x14x0.43mm thick of length 600mm long spaced inter-locked at middle of the first crossed T in each panel to form grid of 1200mmx600mm resting on periphery wall Profile wall section 19mm (7+7) x 19mmx0.40thicknesses and laying false ceiling for services like diffusers grills including cutting, making opening for light fittings, fixtures, , smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. soffit cleats of size 25x35x1.6 mm of required length fixed to the ceiling with 6mm dia and 50mm long dash fastener, 4mm dia G.I. adjustable rods with powder- Ground floor
Providing and fixing false ceiling First Floor
Providing and fixing false ceiling Second Floor
Providing and fixing false ceiling Third Floor
Providing and fixing false ceiling Fourth Floor
Providing groove to required size at specified location as directed by Engineer, at junction of brick masonry wall and R.C.C beams or Column, at junction of composite masonry, including scaffolding, finishing, curing etc. complete. Ground floor
Providing groove to required size First Floor
Providing groove to required size Second Floor
Providing groove to required size Third Floor
Providing groove to required size Fourth Floor
Providing and laying Vitrified MATT finish having decorative type of size 1000 millimeter x 1000 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical and confirming to IS 15622-2006 (Group Bla) of approved make shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints curing and cleaning etc .complete. Ground floor
Providing and laying Vitrified MATT finish First Floor
Providing and laying Vitrified MATT finish Second Floor
Providing and laying Vitrified MATT finish Third Floor
Providing and laying Vitrified MATT finish Fourth Floor
Providing and laying vitrified stone effect finish tiles having size 590 to 605 mm x 590 to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including required position laid on a bed of 1:4 cement mortarincluding neat cement float, filling joints, curign and cleaning etc. complete. Basement Floor
Providing and laying vitrified stone effect finish tiles Ground floor
Providing and laying vitrified stone effect finish tiles First Floor
Providing and laying vitrified stone effect finish tiles Second Floor
Providing and laying vitrified stone effect finish tiles Third Floor
Providing and laying vitrified stone effect finish tiles Fourth Floor
Providing and fixing heavy duty inter locking concrete Coloured paving blocks of 80 mm thickness of having a strength of 300 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete Basement Floor
Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. Basement Floor
Providing and laying machine cut machine Polished Kota stone flooring Ground floor
Providing and laying machine cut machine Polished Kota stone flooring First Floor
Providing and laying machine cut machine Polished Kota stone flooring Second Floor
Providing and laying machine cut machine Polished Kota stone flooring Third Floor
Providing and laying machine cut machine Polished Kota stone flooring Fourth Floor
Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washing etc. complete. For Flooring Basement Floor
Providing Mirror polishing to Kota Stone Ground floor
Providing Mirror polishing to Kota Stone First Floor
Providing Mirror polishing to Kota Stone Second Floor
Providing Mirror polishing to Kota Stone Third Floor
Providing Mirror polishing to Kota Stone Fourth Floor
Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 mm to 30 mm thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete. Basement Floor
Providing and fixing in required position skirting or dado Ground floor
Providing and fixing in required position skirting or dado First Floor
Providing and fixing in required position skirting or dado Second Floor
Providing and fixing in required position skirting or dado Third Floor
Providing and fixing in required position skirting or dado Fourth Floor
Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. Basement Floor
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. Basement Floor
Providing and laying in position flooring of telephone black Ground floor
Providing and laying in position flooring of telephone black First Floor
Providing and laying in position flooring of telephone black Second Floor
Providing and laying in position flooring of telephone black Third Floor
Providing and laying in position flooring of telephone black Fourth Floor
Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. Ground floor
Providing and fixing machine cut machine polished 18 mm to 20 mm thick First Floor
Providing and fixing machine cut machine polished 18 mm to 20 mm thick Second Floor
Providing and fixing machine cut machine polished 18 mm to 20 mm thick Third Floor
Providing and fixing machine cut machine polished 18 mm to 20 mm thick Fourth Floor
Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete. Basement Floor
Providing leather finished polishing to Granite Stone slab Ground floor
Providing leather finished polishing to Granite Stone slab First Floor
Providing leather finished polishing to Granite Stone slab Second Floor
Providing leather finished polishing to Granite Stone slab Third Floor
Providing leather finished polishing to Granite Stone slab Fourth Floor
Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish Basement Floor
Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite Ground floor
Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite First Floor
Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite Second Floor
Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite Third Floor
Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite Fourth Floor
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. Basement
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite Ground floor
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite First Floor
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite Second Floor
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite Third Floor
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite Fourth Floor
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. Basement Floor
Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. Basement Floor
Providing and applying 2 coats of 100% Pure acrylic low VOC and APEO & HCHO free water based paint of approved colour that belongs to class 1 flame spread resistance of approved make Paint should provide durable and long lasting silk finish with a high crack tolerance of upto 1mm. Paint should have an oustanding washability with high resistance to wide range of bacteria and fungus. Paint has to be applied on smooth and uniform surface prepared by an acrylic copolymer low VOC & Odour putty. This surface should be primed with water based low VOC Primer. The work activity should cover all aspects of applying paints from surface preparation as directed by Engineer in charge. Ground floor
Providing and applying 2 coats of 100% Pure acrylic low VOC and APEO & HCHO free water based paint First Floor
Providing and applying 2 coats of 100% Pure acrylic low VOC and APEO & HCHO free water based paint Second Floor
Providing and applying 2 coats of 100% Pure acrylic low VOC and APEO & HCHO free water based paint Third Floor
Providing and applying 2 coats of 100% Pure acrylic low VOC and APEO & HCHO free water based paint Fourth Floor
Providing and applying antipeel paint of approved make & approved brand exterior Emulsion paint of approved quality, colour and shade to old and new surface in two coats, including exterior acrylic primer coat, scaffolding, preparing the surface etc. complete (Heat Reflective Paint). Basement Floor
Providing and applying antipeel paint of approved make Ground floor
Providing and applying antipeel paint of approved make First Floor
Providing and applying antipeel paint of approved make Second Floor
Providing and applying antipeel paint of approved make Third Floor
Providing and applying antipeel paint of approved make Fourth Floor
Providing and applying Dezzly texture paint of Hammer / Screetech on the external plastered surface of approved quality. As directed by Engineer in charge ( Approved by SE PWC Nanded ) Second floor
Providing and applying Dezzly texture paint Third Floor
Providing and applying Dezzly texture paint Fourth Floor
Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC‘s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. Second floor
Providing and applying two coats Apex Third Floor
Providing and applying two coats Apex Fourth Floor
Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete Ground floor
Providing and fixing frame with / without ventilator First Floor
Providing and fixing frame with / without ventilator Second Floor
Providing and fixing frame with / without ventilator Third Floor
Providing and fixing frame with / without ventilator Fourth Floor
Providing and fixing Country teak wood Four leaf paneled shutters, 35 mm thick style and rail and 25 mm thick panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete Ground floor
Providing and fixing Country teak wood Four leaf paneled shutters First Floor
Providing and fixing Country teak wood Four leaf paneled shutters Second Floor
Providing and fixing Country teak wood Four leaf paneled shutters Third Floor
Providing and fixing Country teak wood Four leaf paneled shutters Fourth Floor
Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete Ground floor
Providing and fixing Country cut teak wood double or single leaf panelled shutters First Floor
Providing and fixing Country cut teak wood double or single leaf panelled shutters Second Floor
Providing and fixing Country cut teak wood double or single leaf panelled shutters Third Floor
Providing and fixing Country cut teak wood double or single leaf panelled shutters Fourth Floor
Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. Basement Floor
Providing and fixing solid core flush door shutter in single leaf Ground floor
Providing and fixing solid core flush door shutter in single leaf First Floor
Providing and fixing solid core flush door shutter in single leaf Second Floor
Providing and fixing solid core flush door shutter in single leaf Third Floor
Providing and fixing solid core flush door shutter in single leaf Fourth Floor
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. Basement Floor
Providing and fixing in position powder coated aluminium louvered windows Ground floor
Providing and fixing in position powder coated aluminium louvered windows First Floor
Providing and fixing in position powder coated aluminium louvered windows Second Floor
Providing and fixing in position powder coated aluminium louvered windows Third Floor
Providing and fixing in position powder coated aluminium louvered windows Fourth Floor
Providing and fixing in position anodised (as per IS 1868/1982) Aluminium fixed staggered ( Z Type) Ventilator with aluminium rectangular pipe 63 mm x 38.10 mm x 1.22 mm at weight 0.650 Kilogram/Running metre, Aluminium angle of size 15 mm x 15 mm x 1 mm,aluminium channel of 9 mm sizes, S.S.mosquito net of 304 Grade,4 mm thick float glass per detailed drawing and as directed by Engineer in charge etc.complete. Basement Floor
Providing and Fixing 30 MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER consisting of frame made out of M.S tubes of 19 guage thickness and, size 19 x 19 mm for styles and 15 x15 mm for the top and bottom rails, M.S frame shall have a coat of metel primer of approved make and manufacture. M.S frame shall be covered with heat mouled PVC 'C' channel made from 5 mm (+/0.25) thick prelaminated sheet of density 600 Kilogram/cbm ,of size 30mm thickness 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45? angle on either side forming stiles ; and 5 mm thick ,95 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered in 45 on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 mm (+/0.25) thick PVC strip of 20 mm width is to be stuck on the bottom side of the ' c ' channel prelaminated paneling of 5 mm (+/0.25) thick PVC sheet to be fitted inside the M.S. frame welded/ sealed to the styles and rails with 5 mm (+/0.25) x 30 mm PVC sheet beading on either side and joined together with solvent cement adhesive etc ,10 mm thickness (5 mm (+/0.25) x 2 nos ) 20 mm wide cross Basement Floor
Providing and Fixing 30 MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER Ground floor
Providing and Fixing 30 MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER First Floor
Providing and Fixing 30 MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER Second Floor
Providing and Fixing 30 MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER Third Floor
Providing and Fixing 30 MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER Fourth Floor
Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/Running metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/Running metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram / Running metre. Inter locking section 40 x 18 x1.10 mm at weight 0.469 Kilogram/Running metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram / Running metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With powder coating with box Ground floor
Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks First Floor
Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks Second Floor
Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks Third Floor
Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks Fourth Floor
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/Running metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/Running metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight o.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating with box Basement Floor
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks Ground floor
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks First Floor
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks Second Floor
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks Third Floor
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks Fourth Floor
Sliding window -3 track ( 2 Glass Shutter + 1 flymesh of approved make with DGU, Providing and fixing of Sliding window -3 track ( 2 Glass Shutter + 1 Flymesh ) for details refer to specification as directed by Engineer in charge Ground floor
Sliding window -3 track ( 2 Glass Shutter + 1 flymesh of approved make with DGU, Providing and fixing of Sliding window -3 track First Floor
Sliding window -3 track ( 2 Glass Shutter + 1 flymesh of approved make with DGU, Providing and fixing of Sliding window -3 track Second Floor
Sliding window -3 track ( 2 Glass Shutter + 1 flymesh of approved make with DGU, Providing and fixing of Sliding window -3 track Third Floor
Sliding window -3 track ( 2 Glass Shutter + 1 flymesh of approved make with DGU, Providing and fixing of Sliding window -3 track Fourth Floor
a) Supplying and fixing in position Aluminium four track sliding windows with outer frame made from section of over all size 122 mm x 45 mm, bottom section with drain section track weighing 1.83Kilogramper metre and top and side section of size 122x 31.75 mm weighing 1.15Kilogramper running metre with shutter sections made of 18 mm x 40 mm size having average weight of 0.6Kilogramper running metre (or as required size) with change in proportionate weight, with 6 mm float glass in three equal panels and alluminium coated stainless steel mosquito net in one (2/3 of opening) panel fixed with new neoprene gasket, shutters to be provided with nylon encased stainless steel rollers, necessary locks and handles complete. Ground floor
a) Supplying and fixing in position Aluminium four track sliding windows First Floor
a) Supplying and fixing in position Aluminium four track sliding windows Second Floor
a) Supplying and fixing in position Aluminium four track sliding windows Third Floor
a) Supplying and fixing in position Aluminium four track sliding windows Fourth Floor
Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia. bars 3 Nos. And stirrups @250 mm c/c and fixing in wall with 6 Nos of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc, complete) frame size 60 mm x 100 mm . Terrace floor
Providing and fixing mild steel grill work for windows, ventilators etc. 25 Kilogram/Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Basement Floor
Providing and fixing mild steel grill work for windows, ventilators etc. 25 Kilogram/Square Metre Ground floor
Providing and fixing mild steel grill work for windows, ventilators etc. 25 Kilogram/Square Metre First Floor
Providing and fixing mild steel grill work for windows, ventilators etc. 25 Kilogram/Square Metre Second Floor
Providing and fixing mild steel grill work for windows, ventilators etc. 25 Kilogram/Square Metre Third Floor
Providing and fixing mild steel grill work for windows, ventilators etc. 25 Kilogram/Square Metre Fourth Floor
Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use) Basement
Providing and Fixing mat finish stainless steel (of 302 grade ) railing Ground floor
Providing and Fixing mat finish stainless steel (of 302 grade ) railing First Floor
Providing and Fixing mat finish stainless steel (of 302 grade ) railing Second Floor
Providing and Fixing mat finish stainless steel (of 302 grade ) railing Third Floor
Providing and Fixing mat finish stainless steel (of 302 grade ) railing Fourth Floor
Grab bars-Providing SS grab bars set for accessible toilets comprising of 4 nos. Grab bars as specified below.(1 nos. wing grab bar + 1 nos. L shaped grab bar + 2 nos. straight grab bars = 1 typical set) 27a) Swing grab bar (1 NOS) Providing a S.S. 304 SWING HANDICAP GRAB BAR - 700 mm and of DIA: 32MM and thickness 1.5mm of the roved brand and make. 27b) L Shaped grab bar (1 NOS) Providing S.S. 304 L SHAPED DISABLED GRAB BAR of IZE-600MM (H) X 600MM (D) and 32MM DIA. and thickness mm of the approved brand and make. 27c) Straight grab bar (2 NOS) Providing S.STEEL 304 GRAB RAIL (600 MM),32MM DIA. and thickness 1.5mm of the approved brand and make. Ground floor
Grab bars-Providing SS grab bars First Floor
Grab bars-Providing SS grab bars Second Floor
Grab bars-Providing SS grab bars Third Floor
Grab bars-Providing SS grab bars Fourth Floor
Providing and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.( Jaquar / Hindwar or Equivalent make Confirming Green Bldg Certificate) Basement
Providing and fixing C.P. 2 Way BIB cock Ground floor
Providing and fixing C.P. 2 Way BIB cock First Floor
Providing and fixing C.P. 2 Way BIB cock Second Floor
Providing and fixing C.P. 2 Way BIB cock Third Floor
Providing and fixing C.P. 2 Way BIB cock Fourth Floor
Providing and fixing 25mm diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock. [Without chamber]. Baseement Floor
Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. Basement
Providing and fixing 15 mm dia. screw down bib/ stop tap Ground floor
Providing and fixing 15 mm dia. screw down bib/ stop tap First Floor
Providing and fixing 15 mm dia. screw down bib/ stop tap Second Floor
Providing and fixing 15 mm dia. screw down bib/ stop tap Third Floor
Providing and fixing 15 mm dia. screw down bib/ stop tap Fourth Floor
Providing and fixing 20 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. Basement Floor
Providing and fixing 20 mm dia. screw down bib/ stop tap Ground floor
Providing and fixing 20 mm dia. screw down bib/ stop tap First Floor
Providing and fixing 20 mm dia. screw down bib/ stop tap Second Floor
Providing and fixing 20 mm dia. screw down bib/ stop tap Third Floor
Providing and fixing 20 mm dia. screw down bib/ stop tap Fourth Floor
Providing and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete Basement Floor
Providing and fixing screw down 15 mm dia. wheeled stop tap Ground floor
Providing and fixing screw down 15 mm dia. wheeled stop tap First Floor
Providing and fixing screw down 15 mm dia. wheeled stop tap Second Floor
Providing and fixing screw down 15 mm dia. wheeled stop tap Third Floor
Providing and fixing screw down 15 mm dia. wheeled stop tap Fourth Floor
Providing and fixing push cock (Self closing tap) symet type of 15 mm dia. including necessary socket, testing etc. complete.( Jaquar / Hindwar or Equivalent make Confirming Green Bldg Certificate) Basement Floor
Providing and fixing push cock (Self closing tap) symet type Ground floor
Providing and fixing push cock (Self closing tap) symet type First Floor
Providing and fixing push cock (Self closing tap) symet type Second Floor
Providing and fixing push cock (Self closing tap) symet type Third Floor
Providing and fixing push cock (Self closing tap) symet type Fourth Floor
Providing and fixing White glazed with bottle trap earthenware Wash Hand Basin of 63x45 cm size including cold water piller taps, brackets, rubber plugs and brass chain, stop tap, chromium plate bottle trap and necessary pipe connections including UPAC waste pipe and trap upto the outside face of the wall, making good the damaged surface, testing etc. complete.( Jaquar / Hindwar or Equivalent make Confirming Green Bldg Certificate) Basement Floor
Providing and fixing White glazed with bottle trap earthenware Wash Hand Basin Ground floor
Providing and fixing White glazed with bottle trap earthenware Wash Hand Basin First Floor
Providing and fixing White glazed with bottle trap earthenware Wash Hand Basin Second Floor
Providing and fixing White glazed with bottle trap earthenware Wash Hand Basin Third Floor
Providing and fixing White glazed with bottle trap earthenware Wash Hand Basin Fourth Floor
Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195mm size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 mm thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge.( Jaquar / Hindwar or Equivalent make Confirming Green Bldg Certificate) Ground floor
Providing and fixing Oval Type Under Counter Wash Hand Basin First Floor
Providing and fixing Oval Type Under Counter Wash Hand Basin Second Floor
Providing and fixing Oval Type Under Counter Wash Hand Basin Third Floor
Providing and fixing Oval Type Under Counter Wash Hand Basin Fourth Floor
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. Basement Floor
Providing and laying concrete pipes of I.S.NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Basement Floor
Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Basement Floor
Providing , constructing and fixing 600 mm dia. Inspection chamber made up of Polypropylene / polyethylene material Having 315 mm diameter inlet(s)/outlets and with eccentric reducers as per requirement to connect 160 mm and 200 mm pipes having thickness of 5 mm and 600 mm in height, with inbuilt shaft achieve the invert depth as per site condition of wall thickness of 5 mm having R.C.C. cover and frame fixing in 150 mm thick in c.c.1:2:4, having crushed sand bed of 150 mm thick of size 750 mm dia. Including excavation and refilling the sides of chamber by ?sand crushed cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc.complete. Basement Floor
Providing , constructing and fixing 250 mm dia. Inspection chamber made up of UPVC material of thickness 3.5 mm and height of 259 mm with inlet and outlet of 110 mm dia. with 75 mm dia. U Trap, Ultra shaft pipe of Upvc material having height of 470 mm and fixing Ultra 250 mm dia. UPVC cover and frame in 150 mm thick in c.c.1:2:4, having crushed sand bed of 100 mm thick of size 550 mm dia. Including excavation and refilling the sides of chamber by crushed sand cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc. complete. Basement Floor
Providing , constructing and fixing 450 mm dia. Inspection chamber made up of Polypropylene / polyethylene material of thickness 3.5 mm and height of 388 mm with 160 or 200 mm main inlet (s) outlet and 110 and / or 160 mm branch inlets, with 450 mm dia. Ultra shaft pipe of HDPE material having height of 460 mm, having R.C.C. cover and frame fixing in 150 mm thick in c.c.1:2:4, having crushed sand bed of 150 mm thick of size 750 mm dia. Including excavation and refilling the sides of chamber by sand crushed cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc. complete. Basement Floor
Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. Basement Floor
Providing and fixing 450mm x 550mm size superior type Belgium mirror Ground floor
Providing and fixing 450mm x 550mm size superior type Belgium mirror First Floor
Providing and fixing 450mm x 550mm size superior type Belgium mirror Second Floor
Providing and fixing 450mm x 550mm size superior type Belgium mirror Third Floor
Providing and fixing 450mm x 550mm size superior type Belgium mirror Fourth Floor
Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. Basement Floor
Providing and fixing chromium plated towel rod Ground floor
Providing and fixing chromium plated towel rod First Floor
Providing and fixing chromium plated towel rod Second Floor
Providing and fixing chromium plated towel rod Third Floor
Providing and fixing chromium plated towel rod Fourth Floor
Providing and fixing white glazed earthenware sink 600mm x 200mm x 450mm including all connection of the G.I. supply and P.V.C. waste pipes up to the outside face of the wall, cold water chromium plated screw down bib tap, rolled steel or C.I. brackets, rubber plug with chain and stop tap complete.( Jaquar / Hindwar or Equivalent make Confirming Green Bldg Certificate) Fourt Floor
Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete.( Jaquar / Hindwar or Equivalent make Confirming Green Bldg Certificate) Ground floor
Providing and fixing stainless steel sink First Floor
Providing and fixing stainless steel sink Second Floor
Providing and fixing stainless steel sink Third Floor
Providing and fixing stainless steel sink Fourth Floor
Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete.( Jaquar / Hindwar or Equivalent make Confirming Green Bldg Certificate) Basement Floor
Providing and fixing C.P. Angular stop clock with wall flange Ground floor
Providing and fixing C.P. Angular stop clock with wall flange First Floor
Providing and fixing C.P. Angular stop clock with wall flange Second Floor
Providing and fixing C.P. Angular stop clock with wall flange Third Floor
Providing and fixing C.P. Angular stop clock with wall flange Fourth Floor
Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete.( Jaquar / Hindwar or Equivalent make Confirming Green Bldg Certificate) Basement Floor
Providing and fixing C.P. pillar cock long neck Ground floor
Providing and fixing C.P. pillar cock long neck First Floor
Providing and fixing C.P. pillar cock long neck Second Floor
Providing and fixing C.P. pillar cock long neck Third Floor
Providing and fixing C.P. pillar cock long neck Fourth Floor
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete.( Jaquar / Hindwar or Equivalent make Confirming Green Bldg Certificate) Basement Floor
Providing and fixing C.P. BIB cock with wall flange Ground floor
Providing and fixing C.P. BIB cock with wall flange First Floor
Providing and fixing C.P. BIB cock with wall flange Second Floor
Providing and fixing C.P. BIB cock with wall flange Third Floor
Providing and fixing C.P. BIB cock with wall flange Fourth Floor
Providing and fixing C.P. sink cock with raised J" shaped swinging casted spout ofapproved make including necessary sockets/ union nut etc. complete."( Jaquar / Hindwar or Equivalent make Confirming Green Bldg Certificate) Basement Floor
Providing and fixing C.P. sink cock with raised J" shaped swinging Ground floor
Providing and fixing C.P. sink cock with raised J" shaped swinging First Floor
Providing and fixing C.P. sink cock with raised J" shaped swinging Second Floor
Providing and fixing C.P. sink cock with raised J" shaped swinging Third Floor
Providing and fixing C.P. sink cock with raised J" shaped swinging Fourth Floor
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Fourth Floor
Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirement etc. complete. Fourth Floor
Providing and fixing Shower Head, with shower arm of approved make mixer of including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge.( Jaquar / Hindwar or Equivalent make Confirming Green Bldg Certificate) Basement Floor
Providing and fixing Shower Head, with shower arm Ground floor
Providing and fixing Shower Head, with shower arm First Floor
Providing and fixing Shower Head, with shower arm Second Floor
Providing and fixing Shower Head, with shower arm Third Floor
Providing and fixing Shower Head, with shower arm Fourth Floor
Providing and fixing C.P. wall mixer with provision for overhead shower with 115mm long bend pipe and wall flange of approved make including necessary sockets/union nut etc. complete.( Jaquar / Hindwar or Equivalent make Confirming Green Bldg Certificate) Basement Floor
Providing and fixing C.P. wall mixer with provision for overhead shower Ground floor
Providing and fixing C.P. wall mixer with provision for overhead shower First Floor
Providing and fixing C.P. wall mixer with provision for overhead shower Second Floor
Providing and fixing C.P. wall mixer with provision for overhead shower Third Floor
Providing and fixing C.P. wall mixer with provision for overhead shower Fourth Floor
Providing and Fixing half turn 25 mm dia gun metal flushing cock including all accessories etc. complete. Basement Floor
Providing and Fixing half turn 25 mm dia gun metal flushing cock Ground floor
Providing and Fixing half turn 25 mm dia gun metal flushing cock First Floor
Providing and Fixing half turn 25 mm dia gun metal flushing cock Second Floor
Providing and Fixing half turn 25 mm dia gun metal flushing cock Third Floor
Providing and Fixing half turn 25 mm dia gun metal flushing cock Fourth Floor
Providing and fixing Orissa Pan of size 580x445x260 mm with approved make flush valve including trap, C.I. soil and vent pipe upto outside face of wall including 100mm dia. C.I. plug, bend and necessary pipe connection, etc complete. As directed by Engineer in charge.( Jaquar / Hindwar or Equivalent make Confirming Green Bldg Certificate) Basement Floor
Providing and fixing Orissa Pan of size 580x445x260 mm with approved make Ground floor
Providing and fixing Orissa Pan of size 580x445x260 mm with approved make First Floor
Providing and fixing Orissa Pan of size 580x445x260 mm with approved make Second Floor
Providing and fixing Orissa Pan of size 580x445x260 mm with approved make Third Floor
Providing and fixing Orissa Pan of size 580x445x260 mm with approved make Fourth Floor
Providing and fixing white Opal series European type wall-hung, of size 400mmx370mmx575mm with approved make flush valve including soil pipe, vent pipe upto outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings, cutting & making good walls, floors etc as directed by Engineer in charge.( Jaquar / Hindwar or Equivalent make Confirming Green Bldg Certificate) Basement Floor
Providing and fixing white Opal series European type wall-hung, Ground floor
Providing and fixing white Opal series European type wall-hung, First Floor
Providing and fixing white Opal series European type wall-hung, Second Floor
Providing and fixing white Opal series European type wall-hung, Third Floor
Providing and fixing white Opal series European type wall-hung, Fourth Floor
Providing and fixing white glazed urinal of size 710x460x300mm with sensotronic concealed type flushing valve for urinal with complete kit having fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32mm diameter P.V.C. flush pipe with fitting and flushing arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc complete.( Jaquar / Hindwar or Equivalent make Confirming Green Bldg Certificate) Basement Floor
Providing and fixing white glazed urinal Ground floor
Providing and fixing white glazed urinal First Floor
Providing and fixing white glazed urinal Second Floor
Providing and fixing white glazed urinal Third Floor
Providing and fixing white glazed urinal Fourth Floor
Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete Basement Floor
Providing and fixing 75 mm dia stabiliser pipe Ground floor
Providing and fixing 75 mm dia stabiliser pipe First Floor
Providing and fixing 75 mm dia stabiliser pipe Second Floor
Providing and fixing 75 mm dia stabiliser pipe Third Floor
Providing and fixing 75 mm dia stabiliser pipe Fourth Floor
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Basement Floor
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe Ground floor
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe First Floor
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe Second Floor
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe Third Floor
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe Fourth Floor
Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres Sixth Floor
Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Basement Floor
Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe Ground floor
Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe First Floor
Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe Second Floor
Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe Third Floor
Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe Fourth Floor
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Basement Floor
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe Ground floor
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe First Floor
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe Second Floor
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe Third Floor
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe Fourth Floor
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Basement Floor
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe Ground floor
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe First Floor
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe Second Floor
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe Third Floor
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe Fourth Floor
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Basement Floor
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe Ground floor
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe First Floor
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe Second Floor
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe Third Floor
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe Fourth Floor
Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Basement Floor
Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe Ground floor
Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe First Floor
Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe Second Floor
Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe Third Floor
Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe Fourth Floor
Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Basement Floor
Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe Ground floor
Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe First Floor
Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe Second Floor
Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe Third Floor
Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe Fourth Floor
Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend,connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) Basement Floor
Providing and fixing 15 cm rigid PVC Nahani trap Ground floor
Providing and fixing 15 cm rigid PVC Nahani trap First Floor
Providing and fixing 15 cm rigid PVC Nahani trap Second Floor
Providing and fixing 15 cm rigid PVC Nahani trap Third Floor
Providing and fixing 15 cm rigid PVC Nahani trap Fourth Floor
Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. Basement Floor
Providing and fixing P.V.C. Rain water pipes Ground floor
Providing and fixing P.V.C. Rain water pipes First Floor
Providing and fixing P.V.C. Rain water pipes Second Floor
Providing and fixing P.V.C. Rain water pipes Third Floor
Providing and fixing P.V.C. Rain water pipes Fourth Floor
Providing and laying in trenches 15 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Basement Floor
Providing and laying in trenches 15 mm dai. CPVC pipe Ground floor
Providing and laying in trenches 20 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Basement Floor
Providing and laying in trenches 20 mm dai. CPVC pipe Ground floor
Providing and laying in trenches 25 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Basement Floor
Providing and laying in trenches 25 mm dai. CPVC pipe Ground floor
Providing and laying in trenches 32 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Basement Floor
Providing and laying in trenches 32 mm dai. CPVC pipe Ground floor
Providing and laying in trenches 40mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Basement Floor
Providing and laying in trenches 40mm dai. CPVC pipe Ground floor
Providing and laying in trenches 50mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Basement Floor
Providing and laying in trenches 50mm dai. CPVC pipe Ground floor
Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete Fourth Floor
Providing and fixing Glass self 125 mm wide and 600 mm long with necessary chromium plated brackets providingT.W.gutties etc. complete Basement Floor
Providing and fixing Glass self 125 mm wide and 600 mm long Ground floor
Providing and fixing Glass self 125 mm wide and 600 mm long First Floor
Providing and fixing Glass self 125 mm wide and 600 mm long Second Floor
Providing and fixing Glass self 125 mm wide and 600 mm long Third Floor
Providing and fixing Glass self 125 mm wide and 600 mm long Fourth Floor
Supplying and erecting Automatic Sanitizer Dispenser body size (450mmx300mmx220mm), Wall Mounted With 5Liters Capacity of Sanitization Liquid Container and Operation type (Automatic / Touchless), Sensor type motions senser, Voltage-220V,50Hz, for power consumtion(idel mode)-<3VA and (operation mode) -25A, (MOC-Acrylonitrile butadiene styrene (ABS), Polypropylene (PP), brass), with 6 months waranty against manufacturing defects. Basement Floor
Supplying and erecting Automatic Sanitizer Ground floor
Supplying and erecting Automatic Sanitizer First Floor
Supplying and erecting Automatic Sanitizer Second Floor
Supplying and erecting Automatic Sanitizer Third Floor
Supplying and erecting Automatic Sanitizer Fourth Floor
Providing and fixing in position alluminium strips of size 50mm x 3mm for nosing the steps including fixing with screws and raval plugs, bending and cutting to the required shape and size, finishing with paint, necessary mortar bedding of 1:3 cement mortar to get exact line and level including watering and curing etc.complete Basement Floor
Providing and fixing in position alluminium strips Ground floor
Providing and fixing in position alluminium strips First Floor
Providing and fixing in position alluminium strips Second Floor
Providing and fixing in position alluminium strips Third Floor
Providing and fixing in position alluminium strips Fourth Floor
Providing and fixing lioghtening conductor system comprising of erecting Air-Termination consisting of tubular copper rod of 25mm dia. 1.2 mm thick with multiple points head 1.2 mt. long ( Heavy Duty) welded or clamped to G.I. pipe pole B grade 50 mm diaof requiired length with M.S. round bnase plate 25 Cm diam and 10mm thick at bottom embeded in cement concrete 1:3:6 dfoundation of size 45 cm diam x 45 cm Height and providing earthing with copper earth plate of size 60 x 60 x 0.3 cms with cadmium plated nut bolts to fix earthing strip burried in specially prepared earth pits 1.5 metre below ground level with 40Kilogramcharcoal and salt with altemate layers of charcoal and salt and G.I.pipe 40mm dia 2 meter length burried in earthe upto earthling plate remining portion above ground level for watering and refilling comcpete Note- Copper strip fropm lightening conductor is not considered in this item. Basement Floor
Providing and fixing 90 cm x 60 cm Granite plate engraving 10 cm. height letter, figures including painting the lefters/figures with approved colour and shade complete Basement Floor
Supply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each not less than 0.50 mm thick, total thickness of aluminium composite panels not to be less than 4 mm, the exposed surface thereof shall have Stove lacquered finishing coat not less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50 mm X25mm X 3mm thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 mm X 1200 mm and fixed to the building structure as per design through 50mm X50mm X5 mm MS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge. (Prior permission of S.E. is necessary before inclusion of this item in estimate) Ground Floor
Supply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) First Floor
Supply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) Second Floor
Supply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) Third Floor
Supply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) Fourth Floor
Providing and fixing sky light in R.C.C. roof including frame made of M.S. angle 50 x 50 x 6 mm with hold fast, sheet glass 12 mm thick, Chicken mesh 24 gauge with all accessories and required fixtures and fastening fitting including painting etc. complete. Fourth Floor
Supply and Installation of translucent roof with DPI Flux standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 12 mm thick of 900 mm (min.) width with angular daylighting concept. Panels shall have minimum six layers with truss bridge design for higher flexibility & strength. Panels with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with 3 numbers self-drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005, as per design requirement. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign Terrace Floor
Providing soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick-bats. Basement Floor
RWH - Shallow Percolation Pit providing, constructing 2.0m deep shallow depth percolation pit comprising of 1.0m dia pre-cast RCC rings, 300mm thick side filling around outside of RCC rings (annular space) with 40mm size boulders including filling of percolation pit up to 0.5m depth (from bottom up) with 25-75mm clean washed gravels followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs etc. including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge Basement Floor
Boring/drilling bore well of 150mm dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machinery required for the job, all complete as per direction of Engineer in charge, upto 90m depth below ground level. Ground floor
Providing and Fixing 180 mm diameter PVC Casing pipe (6 kg / cm2) (IS 4985-1988) Casing lowering, grounding etc complete
Carrying out of flushing ( by air lift method ) of PVC casing pipe etc complet
Lowering and grouting of PVC Casing pipe etc complete
Providing and fixing 180 mm dia PVC casing pipe cap etc complete
Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester. Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67% Water absorption (as per ASTM):-0.30% Flammability as per ASTM Tensile strength:-115 MPA Specific Gravity at 25 degree centigrade 1.45 Izod impact strength:-65KJ/M2 Heat defection/distort temperature:-65deg C Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid PVC: -100mm Outlet pipe size rigid PVC:-80mm Gas outlet rigid PVC with Valve: 20mm Bacteria immobilization PVC mattes (on all partition) With DRDO TOT licensee and latest batch certificate(month & year of supply) and capacity as below c) Up to 25 user size (1.5mx1.0mx1.0m), Capacity of biodgester:-1500 liters, Area of top, bottom and side walls:- 8 sq.m, Area of partition walls: 2 sq.m, Total weight of frp: - 82.80 Kilogram, Bacteria inoculums quantity: - 600 liters, Minimum thickness of side walls / top and bottom: 5mm, Number of inside partitions: - 3, Minimum thickness of partition wall: 3mm Basement Floor
d) Up to 40 user size (2.0mx1.0mx1.0m), Capacity of biodgester:-2000 liters, Area of top, bottom and side walls: - 10 sq.m, Area of partition walls: 3 sq.m, Total weight of frp: - 106.20 Kilogram, Bacteria inoculums quantity: - 600 liters, Minimum thickness of side walls / top and bottom: 5mm, Number of inside partitions: - 3, Minimum thickness of partition wall: 3mm Basement Floor
Providing and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles of size 15mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 20mm , suitable for Green Building application, with Recycled content of 32%. The tile shall be laid on precoated G.I.channel on XL2 Clip having a web height of 32 mm with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm and 600 mm Cross Tees with a web height of 32 mm and a load carrying capacity of 7.7 Kilograms/M2 and minimum pull out strength of 100 Kilograms.. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system. The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete. First Floor
Providing and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling System Second Floor
Providing and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling System Third Floor
Providing and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling System Fourth Floor
Providing & Fixing in position Acoustical Doors along with 150 x 150 mm teak wood frame, doors made from 50mm Teak wood frame 600 x600 c to c filled with 1000 Gsm synthetic wool 50mm thick and 3mm Tecsound from both sides, 12mm waterproof ply & veneer from both sides , including 150mm heavy duty SS hinges (Geze / Dorma or eq.) 4 no each leaf, with Door-closer (Dorma / Geze or eq.) including cost of required Cut-Outs, decorative mouldings / finishing-items / melamine polish & Scaffolding as per Architectural & Acoustical Design & Instructions & Complete in all aspects .including all materials labour,finishing etc complete First Floor
Providing & Fixing in position Acoustical Doors Second Floor
Providing & Fixing in position Acoustical Doors Third Floor
Providing & Fixing in position Acoustical Doors Fourth Floor
Design, supply, fabrication and fixing acrylic multilingual Braille (raised dots) signboards of size 6"x 9" for room titles, designed as per the drawings issued and having 4mm thick blue acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word/s written in Hindi with Devnagri non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate. Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate.Each signboard to be fixed as per manufacturers specifications on the wall adjoining the respective room door at a height of 1200mm from FFL and as per the directions by the engineer in charge. Ground Floor -
Design, supply, fabrication and fixing acrylic multilingual Braille First Floor
Design, supply, fabrication and fixing acrylic multilingual Braille Second Floor
Design, supply, fabrication and fixing acrylic multilingual Braille Third Floor
Design, supply, fabrication and fixing acrylic multilingual Braille Fourth Floor
Providing and supplying in standard lengthsH.D.PolyethelenePipes,confirming to IS 4984/14151/12786/13488 with nesessary jointing material like mechanical connector i.e.thread/insert joint/quick release coupler joint/compression fitting jointor flanged joint excluding coupler/specials,including transportation and freight charges,inspection charges,loading/unloading charges,conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains,excluding GST levied by GI & GOM in all respectetc.complete.As per IS:4984-2016 (HDPE Pipes upto 110mm dia. shall be in coil form). Spec. Nos. As directed by Engineer in Charge A ) For 200 mm dia
Providing and supplying in standard lengthsH.D.PolyethelenePipes,confirming to IS 4984/14151/12786/13488 with nesessary jointing material like mechanical connector i.e.thread/insert joint/quick release coupler joint/compression fitting jointor flanged joint excluding coupler/specials,including transportation and freight charges,inspection charges,loading/unloading charges,conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains,excluding GST levied by GI & GOM in all respectetc.complete.As per IS:4984-2016 (HDPE Pipes upto 110mm dia. shall be in coil form). Spec. Nos. As directed by Engineer in Charge B ) For 315 mm dia
Providing and installing 140 A automatic water softner having capacity 10000 Ltr / day , PPL 1200 Resins 350 , Vessel diameter 24 inches , vessel height 72 inches , Silex media 25 kg , output per 1000 Itr on 200 PPM hardness 90 , Maximum flow ( 1000 Ltr / Hr ) 14 , Activation media industrial salt , salt Qty for each recharge 56 kg , Multiport Value size & mounting / pressure guage 50 NB side mount / 0.7 kg / cm 2 max operating pressure 3.50 bar etc complete and as directed by Engineer in charge Ground Floor -
Providing and laying permanent piping technology anti-termite treatment peripheral work by installing LLDP (Low linear density polyethylene) tube of 8 mm O.D. & 6 mm I.D. with inbuilt pressure compensation chip at every 30 cm interval in the tube. The LLDP pipe shall be installed at the entire periphery of the building and at internal network of building at a depth of 20 to 200 mm under floor at every 2 to 3 mtr. distance (adjusted as per building layout) & shall provide a junction to every 200-250 Sqm of building & test every junction during injecting chemicals for termite control treatment. The Imidacloprid 30.5% SC or equivalent make mix as per 6313, (part III) shall be injected by the pressure pump diluted with water 10.5m1/5 Itr of water at 2 kg/sq.cm. 2Ltr/SMT at ground floor level and @1.25Ltr/SMT at other levels.A guarantee bond of 03 years shall be furnished by the contractor inclusive of all material, hire charges, machinery, junction box and labour for making hole, chipping, and clean the surface etc Ground Floor
Preparing Structural Design of Building as Per Approved Drawing Including Providing Details of Loading Pattern as Per Latest Code of Practice, Details of Analysis of Frame Structure Details of Critical Moments and Forces On the Structure Considering Seismic Forces. The Element of the Structure Should Be Confirming to The Architectural Drawings/ The structural model is to be prepared & sizes of members will be assign & then loading on members will be applied & Earth Quake/Wind forces will be generated in staad/Build Master/E.Tabs Software & Analysis will be carried out from this forces. Then whole structure will designed from this Staad Output file the regrouping & according schedules & structure drawings will be prepared for final Submission. 1. Carry out detailed calculation reports.2. Prepare detailed structural working drawings.3. Prepare complete structural design report.4. The Structural Consultant will provide 3 sets of drawings to the employer after getting approval from Government Engineering College/ Government Institutions. 5. The Fees for checking of Government Engineering College/ Government Institutions shall be paid by Contractor as per challan/ demand from Government Engineering College/ Government Institutions.
Providing the consultancy services for GRIHA certification of the building, including all related expenses in achieving Green certification, including all lead, lift and taxes; excluding GST, including conducting all awareness program during inception till the receipt of GRIHA certification and even during 2 years of defect liability period; including the fees for training programme, excluding the fee for statutory requirements and GRIHA certification which will be paid by P.W. Dept. & Site visit piad by the contractor , including all related to the achivement of the GRIHA certification etc. complete and as directed by engineer-in-charge. (For total built up aera of project )
Engaged Computer Opreter for project work
Engaged Assistant for project work
Add Royalty charges etc complete -Sand
Add Royalty charges etc complete - All other Minerals
Carrying out basic test on cement for standard consistancy , fineness , specific gravity , setting time ( initial and final ) compressive strength soundness
Carrying out basic test on sand for Fineness modulus , silt and clay content
Carrying out basic test on sand for Choride and sulphate content etc complete
Carrying out basic test on Aggeregates for water absoption , specific gravity impact value crushing value etc
Carrying out basic test on Aggeregates for sieve analyis
Carrying out basic test on concrete cubes for compressive stength
Carrying out basic test on concrete for mix design
Basic Test of Bricks -Carrying out basic test on Bricks for Water absoprtion , Efflorescence , compressive Stength
Carrying out basic test on Vitrified tiles for water aboprtion , mudulus of rupture
Carrying out basic test on T.M.T. steel ( bar testing above 16 mm ) for Tensile strength , % Elongation , Yield stress , Weigth / m , Bend / rebend test proof test
Carrying out basic test on T.M.T. steel ( bar testing upto 16 mm ) for Tensile strength , % Elongation , Yield stress , Weigth / m , Bend / rebend test proof test
Basic Test of concrete paving block - Carrying out basic test on concrete paving block for Comp. strength , Water absorption , Flexural test , Resistance to water
Basic Test of Mortar - carrying out basic test on mortar for Comp strength
Basic Test of stone / Rubble - carrying out basic test on stone / rubble for crushing value /comp stength water absoprtion and specific gravity
Basic Test of Soil / Murum - Carrying out basic test on soil / murum for field moisture content
Carrying out basic test on soil / murum for liquid limit and plastic limit
Basic Test of wood - Carrying out basic test on wood for density and moisture content
Basic Test of Flush door - Carrying out basic test on flush door knif test , adhesion test and end immersion test
Basic Test of Aluminium section - Carrying out basic test on aluminium section for thickness mass per running meter
Basic Test of AAC Block - Carrying out basic test on Density test , compressive strength , water absorption test
Carrying out basic test PVC Popes for running meter, dia of pipes & wall thickness of pipe
Electric Work Supplying & erecting HMS P.V.C. conduit 25 mm. dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying & laying HMS PVC conduit 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying & erecting HMS P.V.C. conduit 32 mm. dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying & laying HMS PVC conduit 32 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting UPVC reinforced flexible conduit 20 mm in dia. conforming to I.S. with required number of couplings, PVC bushes, check nuts etc. complete.
Supplying and erecting HMS PVC conduit 25 mm dia. with PVC accessories on wall /ceiling as per specification No: WG-MA/CON.
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 40 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying & erecting mains with 2x1.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying & erecting mains with 1x1.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying & erecting mains with 2x2.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying & erecting mains with 2x4 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying & erecting mains with 4x6 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying & erecting mains with 1x6 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying & erecting mains with 4x10 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying & erecting mains with 1x2.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying & erecting mains with 2x1.5 sq.mm. F.R. copper wire, in 16 gauge 20 mm dia. Rigid Steel conduit with continuous GI earth wire of 2.5 sq.mm. as per specification No: WG-MA/MC.
Supplying & erecting mains with 2x2.5 sq.mm. F.R. copper wire, in 16gauge 20 mm dia. rigid steel conduit, with continuous GI earth wire of 2.5sq.mm. as per specification No: WG-MA/MC.
Supplying and erecting Ceiling rose / Batten holder / Slanting holder / hanging cord switch / hanging bell push / pendent holder bakelite base 6A. erected on filled polypropylene board or polished double wooden block/ PVC junction box.
Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type 3 pin 6A multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type telephone socket two gang with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. Note: Add Rs 57/- for additional two module box with double mounting plate if required.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 1 module complete duly erected.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 modules duly erected.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 modules duly erected.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 modules duly erected.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 12 modules duly erected.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background..
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting 16 / 20 / 25 A starter (modular range) 2 module for AC unit on provided box complete & duly concealed with necessary material and connected.
Wiring for plug on board with Modular Switch socket, copper wiring and earthing as per specification No: WG-PW/SW
Wiring for plug on board with Switch socket concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW
Point wiring for light/fan/bell in 20 mm metal conduit with 1.5 sq.mm (2+1E) FR grade copper wire, flush type switch, earthing and required accessories as per specification No: WG-PW/SW
Point wiring for light/fan/bell concealed type in min 20 mm ISI marked HMS PVC conduit with 1.5 sq.mm. (2+1E) FR grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/CW
Point wiring for light/fan/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FR grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW
Point wiring in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FR grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
CF Point wiring in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FR grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
Staircase Point wiring in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FR grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
Supplying & erecting telephone copper cable 5 pair with 0.5 mm dia. laid in provided PVC casing capping / conduit as per specification No. WG-TW
Supplying & installing UTP networking cat-6 cable suitable for LAN / WAN Computer net-working as per specification No. WG-COC/NC
Supplying and fixing tool-less Information Outlet (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO
Supplying and erecting LED square / circular 16 to 20W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying and erecting CRCA /die-cast aluminium powder coated housing LED panel light (slim edge-lit) square / round shape suitable for 19 to 24 W with provision for plane front frame with translucent cover fixed to the housing complete.
Supplying and erecting square / rectangular shaped CRCA /die-cast aluminium powder coated housing LED panel (slim edge-lit) light suitable for 25 to 32W with provision for plane front frame with translucent cover fixed to the housing complete.
Supplying and erecting square shaped CRCA /die-cast aluminium powder coated housing LED panel light (slim edge-lit) 600x600mm suitable for 36 W-40W with provision for plane front frame with translucent cover fixed to the housing complete.
Making suitable size recess in any type of false ceiling for erection of flush type down lighter and finishing the background to match the original surface upto 20W.
Making suitable size of recess in any type of false ceiling for erection of flush type LED panel light 600mm x 600mm and finishing the background to match the original ceiling surface.
Supplying & erecting LED 18W tube light fitting (4 feet) with polycarbonate housing, heat sink, integrated HF electronic driver complete.
Supplying and erecting LED Mirror Light with integrated driver including 7W to 9W lamp with polycarbonate housing and opal diffuser to be fixed above mirror or as required on clamps complete.
Supplying and erecting bulkhead fitting suitable for upto LED upto 12W fixed on wall. As per specification no. FG-IDF/BHF
Supplying & erecting suspension type decorative fitting with rise /fall arrangement, 1 light inside semi-circular metallic reflector with counterweight with guide pulley / spring buffer with work shop type copper flexible wire complete with necessary hook, if required.
Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size
Supplying and erecting luminous / modular type call bell indicator with plastic body, heavy duty coil and indicator lamp working on 230V A.C. supply with resetting arrangement complete erected on double wooden/ sunmica board
Supplying and erecting Electronic Type cordless call bell erected on T.W. board having portable bell push working on 9V D.C. battery and (effective range upto 45 meter) bell on 250 V A.C. supply.
Supplying and erecting LED Street light fitting suitable for above 40W to 48W lamp, including lamp, with PF > 0.95 class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification No . FG-ODF/FLS2.
Supplying and erecting street light Wall bracket made from 40 mm. dia ‘B’ class G.I. pipe 1.2 m in total length complete as per specification no. FG-BKT/WB
Supplying & erecting 5W-7W, 230V integral type LED Lamp suitable for B-22/E-27 base.
Supplying and erecting fresh air cum exhaust fan of light duty250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected in an approved manner.
Supplying and erecting five star rated energy saving Ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia.or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab.
Supplying and erecting ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 40A to 63A in provided distribution board as per specification no. SW-SWR/MCB
Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted SPMCB of 12 ways, on iron /GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted suitable for 3 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles) on iron/ GI frame. (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted suitable for 3 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles) , on iron/ GI frame. (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Providing & erecting 3 Pole MCCB upto 100A, 415V, with short circuit rating 25 kA (Ics=100% of Icu ),adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB
Providing & erecting 4 Pole MCCB upto 100A, 415V, with short circuit rating 25 kA (Ics=100% of Icu ),adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB
Providing & erecting 4 Pole MCCB of 250A,415V capacity with short circuit rating 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB
Providing & erecting 4 Pole MCCB of 315/400A, 415V capacity with short circuit rating 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB
Providing, erecting and commissioning 4 pole RCCB only of electromagnetic type with 30/100/300 mA sensitivity and having capacity of 40A complete as per specification no. SW-RCCB/RCCB
Providing & erecting floor / wall mounting, MCCB panel board with door suitable for four pole incoming 250A, 4 ways four pole outgoing upto 100 A MCCB's on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCB'S)
Providing & erecting floor / wall mounting, MCCB panel board with door suitable for four pole incoming 250A, 8 ways Four pole outgoing upto 100 A MCCB's on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCB'S)
Providing & erecting floor / wall mounting, MCCB panel board with door suitable for four pole incoming 400A, 12 ways four pole outgoing upto 100 A MCCB's on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCB'S)
Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door of 250A incoming and 4 way outgoing or 400A incoming and 2 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB complete.
Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door of 250A incoming and 8 way outgoing or 400A incoming and 6 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB complete.
Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door of 400A incoming and 12 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB complete.
Supplying and erecting air circuit breaker manually operated non-drawout type of 630A rated at 50º C without deration, 500V, 3 pole having short circuit rating 50 kA (Ics=Icu=Icw for 1s),with standard accessories and thermal magnetic release on provided iron frame as per specification no. SW-SWR/ACB
Supplying and erecting metal work in CRCA sheet with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.(Note:-Above rates are inclusive of angle iron work.)
Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting self-locking arrangement with keys in duplicate, made of brass duly erected, flush with surface of panel / cupboard.
Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V 630A complete as per specification no. CP-BB
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.
Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.
Supplying, erecting & terminating XLPE armoured cable 3½ core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 70 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 150 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½core 240 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 300 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying & laying (including excavation) 25 cm dia RCC Hume pipe of standard thickness at required depth up to 90 cms. below road / ground surface, for covering provided cable & necessary back filling with light ramming to make the road/ground surface as it was (Except bitumen carpet).
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 200 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
Providing & erecting Hot dipped galvanized cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware in approved manner.
Providing & erecting Hot dipped galvanized cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) GI sheet of 200 mm width & 20 mm height complete with necessary hardware in approved manner.
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no. EA-EP.
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP.
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Excavating hard murum / metal road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site as required complete.
Making burnt brick masonry with 1:6 ratio cement concrete duly plastered including watering, streaking joint on exposed faces, rocking at joint on exposed faces and watering complete.
Supplying and erecting RCC chamber cover with frame 60cmx 45cm medium duty 100kg with lifting arrangement including laying of angle iron frame of angle size as 50 x 50 x6 mm to be fixed / embedded on top of chamber complete.
Harsh Constructions Pvt Ltd
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Download all tender documents and submit your bid