Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹21.4 L+₹1.4 L (6.86%)Rejected-Finance B 33 171 PATEL NAGAR GURUDASPUR ROAD PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Other than Lowest bidder | |
| 3 | L3₹21.5 L+₹1.6 L (7.82%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest bidder | |
| 4 | L4₹22.7 L+₹2.7 L (13.6%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest bidder | |
| 5 | L5₹23.1 L+₹3.1 L (15.8%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
20 Jun 2023, 6:00 pmClosed
Garrison Engineer Brichgunj
Garrison Engineer Brichgunj Port Blair
REPAIR AND MAIN.OF INTERNAL ELECTRICAL FITTINGS AND FIXTURES AND OTHER CONNECTED INTERNAL ACCESSORIES IN MD ACCN UNDER GE BRICHGUNJ
2023_MES_599660_1
8360A
Open Tender
Civil Works
Item Rate
330 days
Brichgunj
As per NIT
8 documents required · 8 mandatory
₹500
Garrison Engineer Brichgunj
₹40,000
Yes
14 Jul 2023
30 May 2023
22 Jun 2023
30 May 2023
20 Jun 2023
14 Jun 2023
Amount
Taking down carefully, copper/aluminium point wiring (Light, fan, scoket or power) complete, including fittings and fixtures such as switches, ceiling roses, regulators, sockets etc., and making good disturbed surfaces of walls floors, etc., complete all as specified and as directed by Engineer-in-Charge.
M&L Point wiring complete with 1.5 sqmm single core FRLS PVC insulated and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC casing and caping and all accessories fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover/Pre moulded PVC switch board for housing the switches, socket outlets, fan regulators etc., all as specified and as directed for the following: - (a) One light point/Bell point controlled by one switch
(b) One fan point controlled by one switch and one regulator
(c) One 3 pin switch socket outlet point 5 amps on same board with other switches.
(d) One light point controlled by two two way switch.
(d) One 3 pin switch socket outlet point 5 amps on independent board.
All as per item at sl No.2 here in before but with copper conductor cable for one 3 pin socket outlet, 15 amps independent, with cable 4 Sqmm size and 4Sqmm earth continuty conductor, complete all as specified and as directed by Engineer-in-Charge.
M&L Point wiring complete with 1.5 sqmm single core FRLS PVC insulated and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC conduit and all accessories fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable green in colour as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlets, fan regulators etc., all as specified and as directed for one light point controlled by one one way switch.
All as per item No. 4 here - in - before but for one fan point controlled by one 5 Amps switch with 1.5 sq mm copper conductor cable.
All as per item No. 4 here - in - before but for 3 pin 5 Amps switch socket combination on independent board.
All as per item No. 4 here - in - before but for 5 Amps socket point on the same board controlled by one switch.
All as per item at sl No.4 here in before but with copper conductor cable for one 3 pin socket outlet, 15 amps independent, with cable 4.0 Sqmm size and 4.0 Sqmm earth continuty conductor, complete all as specified and as directed by Engineer-in-Charge.
Material & labour for point wiring as per colour coding with 1.5 sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 19 mm thick rigid non metallic PVC concealed conduit medium quality including new sunken terminal boxes duly epoxy painted and 3mm thick plastic laminated sheet top cover and continuity earth wire PVC insulated copper conductor standard unsheathed of size 1.5sqmm including Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills sunshades, shelves, lintels, etc.; and cutting chases for concealed conduit wiring,etc., and making good, cutting not exc 10 cm girth in brick wall. complete all as specified and as directed by Engineer-in-Charge. (a) One light point/Bell point controlled by one switch
(b) One fan point controlled by one switch and one regulator
(c) One 3 pin switch socket outlet point 5 amps on same board with other switches.
(d) One light point controlled by two two way switch.
(e) One 3 pin switch socket outlet point 5 amps on independent board.
All as per item at sl No 6 here in before but with copper conductor cable for one 3 pin socket outlet, 15 amps independent, with cable 4 Sqmm size and 4Sqmm earth continuty conductor, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for point wiring with 1.5 Sqmm FRLS PVC insulated single core stranded copper conductor unsheathed cable in the existing PVC concealed conduit/ surface conduit including fittings and accessories complete with PVC insulated copper conductor earth wire 1.5 Sqmm for one light/ one bell/ fan point through regulator point controlled by one switch in old/ existing cast iron/ pressed steel terminal boxes but with new 3 mm thick plastic laminated sheet top cover, painting existing sunken boxes with anticorrosive bituminous paint after thorough cleaning complete all as specified.
All as per srl item No. 8 here in before but for 2/3 pin socket outlet 5 Amps multi purpose on independent board including continuous earth wire PVC insulated unsheathed copper conductor 1.5 Sqmm and connected to earth dolly, complete all as specified and directed.
All as per srl item No. 8 here in before but for 2/3 pin socket outlet 5 Amps on the same board including continuous earth wire PVC insulated unsheathed single core stranded copper conductor 1.5 Sqmm and connected to earth dolly, complete all as specified and directed
Material and labour for point wiring with 4 Sqmm FRLS PVC insulated and unsheathed single core stranded copper conductor cable in existing PVC concealed conduit/Surface conduit for 2 in one, 3 pin 5 Amps & 15 Amps multi purpose socket on independent board and existing cast iron or pressed steel terminal box with new laminated sheet top cover 3 mm thick, including PVC insulated & unsheathed copper conductor cable 4 Sqmm size for earth continuity conductor and connected to earth dolly including painting to existing sunken boxes with anticorrosive bituminous paint after through cleaning, all as specified and directed.
Supply and fix switch piano flush type single pole one way 5 amps, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix switch socket combination 2 in 1, 3 pin (mult pin) 5 amps flush/box type, complete all as specified and as dircted by Engineer-in-Charge.
Supply and fix switch socket combination 2 in 1, 3 pin (mult pin) 5 and 15 amps flush/box type, complete all as specified and as dircted by Engineer-in-Charge.
Supply and fixing socket outlet flush type 2/3 pin 5 Amps multipurpose, all as specified and directed.
Supply and fix ceiling rose surface baklite 65 x 50 mm 3 terminal, complete all as specfified and as directed by Engineer-in-Charge.
Supply and fix lamp holder(angle type) PVC body with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix bell push single phase, 240 Volts, 50 Hz, complete all as specified and as directed by Engineer-In-Charge.
Supply and fix switch piano flush type single pole two way 5 amps, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix switch piano type, flush type, single pole, one way, 15 Amps, all as specified and directed
Supply and fix socket flush type, multi purpose 2/3 pin, 5 Amps & 15 Amps, 230 volts, all as specified and directed
Supply and fix fan speed regulator, electronic suitable for single phase AC, 240 volts, 50 Hz,100 watts, complete all as specified and as directed by Engineer-in-Charge Make:-Anchor/Havells/Bajaj
Supply and fix bell Ding Dong 240 Volts 50 Hz complete all as specified and directed by Engr-in-Charge.
Supply and fix bell Multi music type 240 Volts 50 Hz complete all as specified and directed by Engr-in-Charge.
Supply and fixing Modular switch 1 way 5 A, 1 module all as specified and directed.
Supply and fixing Modular switch 1 way 15 A, 1 module all as specified and directed.
Supply and fixing Modular Bell push 5A, 1 module all as specified and directed.
Supply and fixing modular socket outlet, 2/3 pin combined , 6/16 Amps, combined 2 module, 230 volts all as specified and directed.
Supply and fixing modular socket outlet, 2/3 pin combined , 6 Amps, combined 2 module, 230 volts all as specified and directed.
S & F modular white cover plate with frame, 1 module all as specified and directed.
S & F modular white cover plate with frame, 2 module all as specified and directed.
S & F modular white cover plate with frame, 3 module all as specified and directed.
S & F modular white cover plate with frame, 4 module all as specified and directed.
S & F modular white cover plate with frame, 6 module all as specified and directed.
S & F modular white cover plate with frame, 8 module all as specified and directed.
S&F PVC blanking plate
Supply and fixing modular fan step regulator, 230 V, AC, 120W - 2 module
Supply and fix in repair metal enclosure distribution board SPN, 12way 240 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs, including taking down old MCB/DB, complete all as as specified and as directed by Engineer-in-Charge Make :Legrand/C&S/L&T Note:- Incoming & Outgoing connections from the DB shall be provided with proper lugs/thimbles etc...
All as per item Sr No 41.00 above but distribution board SPN, 8 way 240 volts complete all as specified and directed.
All as per item Sr No 41.00 above but distribution board SPN, 4 way 240 volts complete all as specified and directed.
All as per item Sr No 41.00 above but distribution board SPN, 2 way 240 volts complete all as specified and directed.
Supply and fix sheet metal enclosures Loadline vertical distribution board TPN, 4 ways 415 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs and in and including 63A MCCB ,16KA as incomming complete all as specified and as directed including taking down old MCB DBs complete including cutting chases pinning in making good to facings where required and pointing in cement mortar 1:3 ends of edges of landing,steps, cills sunsades,shelves,lintels,etc and cutting for concealed conduit wiring etc and making good,cutting not exc 10 cm girth in brick wall complete all as specified.
All as per item Sr no 42.00 above but incomming MCCB of size 160 A, 25 KA complete all as specified and directed.
Supply and fix in repair metal enclosure distribution board TPN, 4 way 415 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs, including taking down old MCB/DB, complete all as as specified and as directed by Engineer-in-Charge Make :Legrand/C&S/L&T Note:- Incoming & Outgoing connections from the DB shall be provided with proper lugs/thimbles etc...
Supply and fix in repair MCB triple pole and neutral 63 amps C series complete all as specified and as directed by Engineer-in-Charge
Supply and fix in repair MCB triple pole 63 amps, C series complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair MCB triple pole and neutral 32 amps C series complete all as specified and as directed by Engineer-in-Charge
Supply and fix in repair MCB triple pole and neutral 40 amps C series complete all as specified and as directed by Engineer-in-Charge
Supply and fix in repair MCB single pole and neutral, 240 volts, 6 to 32 amps C series complete all as specified and as directed by Engineer-in-Charge .
All as per item no 49 above Capacity 40 Amps
Supply and fix in repair MCB single pole 240 volts, 6 to 32 amps complete all as specified and as directed by Engineer-in-Charge Make : Legrand/C&S/L&T
S & F in repairs Single Pole and Neutral Enclosure with Two Pin Earth Plug and Socket complete with one MCB, SP, 20 Amps, 240 Volts fixed on flat iron 32x6 mm or 2nd class hard wood wooden board complete all as specified and as directed.
Supply and fix Cordless bell 240 Volts 50 Hz complete all as specified and directed by Engr-in-Charge.
Supply and fix Wall mounting fan electric driven single phase230 volts, oscillating type,400/450 mm sweep, high quality ABS base with high speed motor and balanced blades and three leafed with 3 core copper cable of suitable size, completeand taking down of unserviceable item all as per specified.
Supply and fix Plastic exhaust fans electric driven AC single phase 230 volts 200/250 mm sweep with louvers including grouting and making whole in wall and taking down of unserviceable item complete all as specified.
Taking out and dismantling the burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding the exhaust fan of size 300/380/400/450mm sweep motor with super enamelled copper winding wire of suitable SWG including varnishing, baking in oven and reassemling refixing at same/ required location, complete all as specified and as directed by Engr-in-Charge.
Taking out and the burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding the wall mounted fan of size 400/450mm sweep motor with super enamelled copper winding wire of suitable SWG including varnishing, baking in oven and reassemling complete all as specified and as directed by Engr-in-Charge.
Supply and fix wall mounted fan covering Net
Supply and fix wall mounted fan blade
Dismantling the burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding with new rotor shaft the ceiling fan of size 1200mm/1400mm sweep motor with super enamelled copper winding wire of suitable SWG including varnishing, baking in oven and reassemling and painting with existing colour with blades complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repairs ceiling fan hanging clamp with bush,locking pin and nut and bolt Including taking down complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repalcement canopy of ceiling fan, complete all as specified and as directed by Engr-in-Charge.
Supply and fix ball bearing suitable for ceiling fan of any sweep and make complete all as specified and as directed by Engr-in-Charge.
Supply and fix down rod of appropriate size suitable for ceiling fan of any sweep and make complete all as specified and as directed by Engr-in-Charge.
Supply and fix fan blade appropriate size suitable for ceiling fan of any sweep and make complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repairs ball bearing suitable for exhaust fan of any sweep and make complete all as specified and as directed by Engr-in-Charge.
Taking down exhaust fan of any size/sweep from existing position complete with blades from brackets etc and servicing the same properly by cleaning, greasing, oiling replacing the unservicable spare parts etc, and reassembling and refixing in the same position all as specified and as directed by Engr-in-Charge. (Note: cost of spare parts shall be measured and paid separately as supplied only. The cost of labour for replacement of spare parts deemed to be included under this item)
Taking down wall mounted fan of any size/sweep from existing position complete with bladesfrom brackets etc and servicing the same properly by cleaning, greasing, oiling replacing the unservicable spare parts etc, and reassembling and refixing in the same position all as specified and as directed by Engr-in-Charge. (Note: cost of spare parts shall be measured and paid separately as supplied only. The cost of labour for replacement of spare parts deemed to be included under this item)
Disconnecting the existing unserviceable MCCB from panel board after disconnecting cable & supply & fix new MCCB 63A, 4 Pole, 16 KA,adjustable , fixed in existing panel including modification of existing frame and panel board door for proper installation of MCCB and connecting with existing cable including thimble,nut bolt and washers etc complete.
All as per above item Sr No 69.00 but MCCB 160A, 4 Pole,25 KA,adjustable complete all as specified and as directed.
All as per above item Sr No 69.00 but MCCB 63A, 3Pole, 16 KA,adjustable complete all as specified and as directed.
All as per above item Sr No 69.00 but MCCB 100A, 3 Pole, 25 KA,adjustable complete all as specified and as directed.
M & L in repairs for sub main wiring complete with three runs of 6 Sqmm FRLS single core PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor (ISI Marked) drawn through and including PVC Casing and caping and all accessories fixed to wall/ roofs/ floors etc with one run of 6 sqmm FRLS single core multistranded copper conductor as earth continuity conductor, including dismantling unserviceable sub main wiring including accessories,complete all as specified and as directed by Engineer-in-Charge. Note : (1) Three runs of cable one run of conduit & one run of earth continuity conductor shall be measured as one running metre.
All as per above item Sr No 73.00 but of size 4 sqmm complete all as specified and as directed.
M & L in repairs for sub main wiring complete with two runs of 6 Sqmm FRLS single core PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor (ISI Marked) drawn through and including PVC Casing and caping and all accessories fixed to wall/ roofs/ floors etc with one run of 6 sqmm FRLS single core multistranded copper conductor as earth continuity conductor, including dismantling unserviceable sub main wiring including accessories,complete all as specified and as directed by Engineer-in-Charge. Note : (1) Two runs of cable one run of conduit & one run of earth continuity conductor shall be measured as one running metre.
M & L in repairs for circuit wiring complete with two runs of 1.5 Sqmm FRLS single core PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor (ISI Marked) drawn through and including PVC Casing and caping and all accessories fixed to wall/ roofs/ floors etc with one run of 1.5 sqmm FRLS single core multistranded copper conductor as earth continuity conductor, including dismantling unserviceable sub main wiring including accessories,complete all as specified and as directed by Engineer-in-Charge. Note : (1) Two runs of cable one run of conduit & one run of earth continuity conductor shall be measured as one running metre.
All as per above item Sr No 76.00 but sub main wiring of size 2.5 sqmm complete all as specified and as directed.
All as per above item Sr No 76.00 but of size 4 sqmm complete all as specified and as directed.
Supply & Fixing in repair PVC Casing caping of following sizes with accessories like PVC saddles, bend,Tees,Elbow and screws etc. (a) 25 mm
S & F in repairs Heavy duty PVC Domestic Surface type for Switches of following sizes(a) 1 Gang Box
(b) 2 Gang Box
(c) 3 Gang Box
(d) 4 Gang Box
(e) 5 Gang Box
(f) 6 Gang Box
(g) 7 Gang Box
Supply and replace in repairs fan condenser 2.0/2.5/4.0 mfd, AC 240 volts, 50 Hz complete all as specified and as directed by Engr-in-Charge.
Supply and fix 3 pin Plug Top for 5Amps complete all as specified and as directed.
Supply and fix 3 pin Plug Top for 15Amps complete all as specified and as directed.
Supply and fix 20/25mm flexible PVC pipe complete all as specified and as directed.
Material & labour, earthing complete with galvanize steel earth plate electrode 60 cms x 60 cms x6.00mm thick buried directly in ground vertically to a depth not less than 2.25 meter below ground level with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4.0mm by means of bolts ,nuts ,check nuts and washers of galvanized iron or steel and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron or steel pipe light grade 40 mm bore and water pipe 20 mm bore GI light grade (ISI marked ) with funnel and wire mesh ,including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No, 5 of MES Sch Part-1 (2009), complete all as specified.
M&L in repairs Stringing drawing earth continuity wire PVC insulated unsheathed multistranded copper conductor FR/FRLS by opening junction boxes/corner/wall paneling/ fitting/ fixtures etc connecting to common earth point & connecting to earth dolly for following sizes.(a) 1.5 Sq mm
(b) 4 Sq mm
S&F 1100 Volt grade heavy duty twin core 10 Sq mm of size,(2 core) flat or circular cable PVC tape and over all PVC sheathed as in sevice connections suspended by insulated hangers not more than 1.00 meter apart including 4 mm dia GI suspension wire and taking down old unservicable wire of any type and any size complete all as specified.
S&F 1100 Volt grade twin core 1.0 Sq mm of size,(2 core) flat or circular cable PVC tape and over all PVC sheathed as and taking down old unservicable wire of any type and any size complete all as specified.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground vertically to a depth not less than 2.25m deep below the ground level with top edge of the plate not less than 1.5mtr below ground level connected to galvanised steel earth strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C-1 precast RCC (1:2;4) type B1 cover slab 54x54x5 cm reinforced with and including 8 mm dia TMT bars @ 150 MM C/C both ways with on handle for lifting madeout of 16 MM dia TMT bars embeded in precast cover slab funnel, wire mesh 20 mm bore GI pipe (medium grade) for watering charcoal and salt in alternate layers 40 mm bore galvanised steel tubing light grade for protection to earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown on electrical plate No. 3 of SSR Part-I (2009)
Taking out old unserviceable GI strip,
Material and labour for Galvanised iron strip of size 32x6mm complete all as specified and directed by Engr-in-charge.
S & F LED light fitting 7 Watt,6500k round/ sqaure shaped surface mounted LED slim panel with diffuser including high efficiency electronic driver complete with LED lamp, prewired upto connection block and connecting with three core PVC copper flexible cable from ceiling rose to connector block, including taking down old unserviceable surface mounted fitting of any wattage, complete all as specified and directed by Engineer-in-Charge.
S & F LED spot light fitting 7 Watt, 3000k housing square/round shaped Recess mounted LED slim panel with PMMA diffuser including high efficiency electronic driver complete with LED lamp, prewired upto connection block and connecting with three core PVC copper flexible cable from ceiling rose to connector block, including taking down old unserviceable spot fitting of any wattage, complete all as specified and directed by Engineer-in-Charge.
S & F LED tube light fitting 2 feet, 1 x 10 Watt provided with high output diffuser including high efficiency electronic driver complete with LED lamp, prewired upto connection block and connecting with three core PVC copper flexible cable from ceiling rose to connector block, including taking down old unserviceable light fitting of any wattage, complete all as specified and directed by Engineer-in-Charge.
S & F LED Bed side1 x 2 Watt, Bronze Metal Synthetic provided with high output diffuser including high efficiency electronic driver complete with LED lamp, prewired upto connection block and connecting with three core PVC copper flexible cable from ceiling rose to connector block, including taking down old unserviceable bed light fitting of any wattage, complete all as specified and directed by Engineer-in-Charge.
S & F Wall light suitable for LED Lamps upto 20 Watt of B22 base, white colour provided with high output diffuser and metal base, prewired upto connection block and connecting with three core PVC copper flexible cable from ceiling rose to connector block, including taking down old unserviceable wall light fitting of any wattage, complete all as specified and directed by Engineer-in-Charge.
S & F LED Cove lighting ( Each Cove lighting Lenth 5 mtr)provided with high output diffuser including high efficiency electronic driver complete with LED lamp, prewired upto connection block and connecting with three core PVC copper flexible cable from ceiling rose to connector block, including taking down old unserviceable cove light fitting of any wattage, complete all as specified and directed by Engineer-in-Charge.
S & F LED Ceiling/wall light 4x4W LED Spot Lights including high efficiency electronic driver complete with LED lamp, prewired upto connection block and connecting with three core PVC copper flexible cable from ceiling rose to connector block, including taking down old unserviceable mirror light fitting of any wattage, complete all as specified and directed by Engineer-in-Charge.Make -Philips Model No-56244/31 or Equivalent in Cormpton/Havells.
Supply and fix Recess mounted LED slim 15 w Round type downlighter with die cast aluminium housing prewired upto connection block and connecting with three core PVC copper flexible cable from ceiling rose to connector block, including taking down old unserviceable fitting of any wattage, complete all as specified and directed by Engineer-in-Charge.
Supply and fix surface mounted LED 12 w Round type downlighter with die cast aluminium housing coating prewired upto connection block and connecting with three core PVC copper flexible cable from ceiling rose to connector block, including taking down old unserviceable fitting of any wattage, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type 4 feet with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as directed and as specified by the engineer in charge.
S & F in replacement recess mounting type LED Panel lights fitting of dimension 2x2 feet, 34W, 220V, AC with driver including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as directed and as specified by the engineer in charge.
M<est point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw
KAPOOR AUTOMOBILES
M/s K Moorthi
M/s Kamal Electrical
Vandana Enterprises
Nirman Construction Company
M/s USHA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .