| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.9 LAccepted-AOC MAHARASHTRA | KOLHAPUR | MAHARASHTRA | 415101 | ₹33.9 L | L1 | Accepted-AOC AS PER BOQ SUMMARY |
| 2 | L2₹34.6 LRejected-AOC | ₹34.6 L | L2 | Rejected-AOC AS PER BOQ SUMMARY |
| 3 | L3₹35.1 LRejected-AOC | ₹35.1 L | L3 | Rejected-AOC AS PER BOQ SUMMARY |
Tender Value
₹33.9 L
EMD Value
₹33,856
Closing Date
17 Jan 2026, 6:55 pmClosed
Executive Engineer Works Dept ZP Parbhani
Executive Engineer Works Dept ZP Parbhani
Providing Electrical Installation, Street Light in Premises and 10KWP Solar Roof Top for newly Constructed Public Health Centre and Staff Quarters Buidling at Pimpaldhari. TQ Gangakhed and Dist. Parbhani.
2026_PARBH_1268178_1
ZPPBN/WD/eTENDER/423/25-26
Open Tender
Electrical Works
180 days
Tq. Gangakhed and Dist. Parbhani.
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,400
₹33,856
10 Mar 2026
10 Jan 2026
19 Jan 2026
10 Jan 2026
17 Jan 2026
10 Jan 2026
Supplying and erecting 20mm dia. corrugated flexible polypropylene conduit . DSR I.No. 1.2.1 (new) [PART A]
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With PVC accessories on wall /ceiling as per specification No: WG-MA/CON.DSR 1.2.4. [PART A]
Supplying and erecting HMS PVC conduit 25 mm dia.with PVC accessories on wall /ceiling as per specification No: WGMA/ CON, para no. 1.1.1. DSR I.No. 1.2.7. [PART A]
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON. DSR I.No. 1.2.8.[PART A]
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 40 mm with accessories on wall/ceiling as per specification No: WG-MA/CON. DSR I.No. 1.2.9. [PART A]
Supplying & erecting mains with 2x1.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/BW. DSR I.No. 1.3.1 [PART A]
Supplying & erecting green earth wire 1 x1.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/BW. DSR I.No. 1.3.1 [PART A]
Supplying and erecting mains with 1 x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW. DSR I.no. 1.3.2. [PART A]
Supplying and erecting green earth wire 2 x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW. DSR I.no. 1.3.2. [PART A]
Supplying & erecting mains with 1 x 4 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW. DSR I.No. 1.3.3. [PART A]
Supplying & erecting mains with 2 x 4 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW. DSR I.No. 1.3.3. [PART A]
Supplying and erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW. DSR I.no. 1.3.4. [PART A]
Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW. DSR I.No. 1.3.4. [PART A]
Supplying and erecting mains with 4x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW. DSR I.No. 1.3.4. [PART A]
Supplying and erecting mains with 1x 10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW. DSR I.No. 1.3.5. [PART A]
Supplying and erecting mains with 4 x 10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW. DSR I.No. 1.3.5. [PART A]
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. DSR I.no. 1.6.1. [PART A]
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. DSR I.no. 1.6.2. [PART A]
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete . DSR I.No. 1.6.10 [PART A]
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. DSR I.No. 1.6.11. [PART A]
Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete. DSR I.no. 1.6.14. [PART A]
Supplying and erecting modular type telephone socket two gang with safety shutter, duly erected on provided plate and box with wiring connections complete. DSR I.No. 1.6.16 [PART A]
Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. DSR I.no. 1.6.23. [PART A]
Supplying and erecting modular type blanking plate one module, duly erected on provided plate & box. DSR I.No.1.6.24. [PART A]
Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 module duly erected. DSR I.No. 1.6.27. [PART A]
Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected. DSR I.No. 1.6.30 [PART A]
Supplying and erecting 16 / 20 / 25 A starter (modular range) 2 module for AC unit on provided box complete & duly concealed with necessary material and connected. DSR I.No. 1.6.43 [PART A]
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/ CW DSR I.No. 1.7.26[PART A]
Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW. DSR I.No. 1.7.19 [PART A]
Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing andrequired accessories as per specification No: WG-PW/SW. DSR I.No. 1.7.20 (NEW) [PART A]
Supplying & erecting 5 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No.WG-TW DSR I.Bo. 1.8.4. [PART A]
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC dSR I.No. 1.10.1 [PART A]
Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS dSR I.No. 1.11.3 [PART A]
Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. DSR I.No. 1.12.1. [PART A]
Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO DSR I.No. 1.12.2 [PART A]
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK DSR I.No. 1.12.17 [PART A]
Supplying and erecting LED square / circular Max. 14 W down lighter / Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. DSR I.No. 2.1.4. [PART A]
Supplying and erecting LED square / circular Max25 W down lighter / Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min.2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg.,max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. DSR I.No. 2.1.6. [PART A]
Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B-22 / E-27 base. DSR I.No. 2.8.11. [PART A]
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. DSR I.No. 2.1.18 [PART A]
Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size. DSR I.No. 2.3.13. [PART A]
Supplying and erecting Electronic type cordless call bell erected on T.W. board having portable bell push working on 9V D.C. battery and (effective range upto 45 meter) bell on 250 V A.C. supply. DSR I.No. 2.3.15. [PART A]
Supplying and erecting integrated LED street light fitting 40 to 50W IP65 &IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. DSR I.no. 2.4.4. [PART A]
Supplying and erecting street light Wall bracket made from 40 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG- KT/WB. DSR I.No. 2.7.4. [PART A]
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete. DSR I.No. 2.10.14 [PART A]
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF DSR I.No. 2.10.22. [PART A]
Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original. DSR I.No. 2.11.4. [PART A]
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. DSR I.No. 2.11.6 [PART A]
Supplying and erecting storage type water heater 25 litres capacity having standing loss <0.511kWh/24hour/45°C, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank, heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal function cut-out, valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no. AP-WH/STWH DSR I.No. 3.1.2. [PART A]
Supplying and erecting chromium plated heavy duty brass stop cock for inlet pipe of water heater (15mm. dia). DSR I.No. 3.1.7. [PART A]
Supplying & erecting 15mm brass non return valve for inlet pipe of storage water heater. DSR I.No. 3.1.8. [PART A]
Supplying & erecting dead weight pressure releasing valve for storage water heater with necessary materials complete. DSR I.No. 3.1.9 [PART A]
Supplying & erecting vacuum relief valve for storage water heater with necessary materials complete. DSR I.no. 3.1.10 [PART A]
Providing fiber reinforced PVC flexible pipe upto 1m length with brass locking nuts and washers and clips at both ends suitable for hot water and cold water both (1 set of 2 nos.) complete. DSR I.no. 3.1.11.[PART A]
Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 5.00 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC dSR I.No. 3.2.11. [PART A]
Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. AP-WCR/WC DSR I.No. 3.3.9 [PART A]
Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200). DSR I.no. 3.5.1. [PART A]
Supplying, installing, testing and commissioning of single phase, 230V, 50 Hz, 1400 to 1600VA digital pure sine wave inverter with backup time of ........ hrs. based on Insulated Gate Bipolar Transistor (IGBT) technology complete as per specification no. AP-INV DSR I.No. 3.6.3 [PART A]
Supplying and erecting 12V/150Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. DSR I.No. 3.8.4. [PART A]
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB. DSR I.No. 5.3.2. [PART A]
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB. DSR I.No. 5.3.3. [PART A]
Supplying, erecting & marking DPMCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB. DSR I.No. 5.3.6 [PART A]
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB. DSR I.No. 5.3.11. [PART A]
Supplying, erecting and marking four pole isolators only switch version of miniature circuit breakers of 63A in provided distribution board. DSR I.No. 5.3.19 [PART A]
Supplying & erecting triple pole and neutral distribution board (TPNDB), SP / TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface /flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB. DSR I.No. 5.4.1 [PART A]
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB. DSR I.No. 5.4.9. [PART A]
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. DSR I.no. 5.4.13. [PART A]
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1. DSR I.No. 5.4.16 [PART A]
Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/ trip alarm contact. MCCB with phase barriers on both sides, insulation withst and capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB. DSR I.No. 5.5.1 [PART A]
Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB DSR I.No. 5.6.2 [PART A]
Supplying, erecting & commissioning 4 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB DSR I.No. 5.6.5. [PART A]
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. DSR I.No. 6.1.19 [PART A]
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL DSR I.No. 7.1.28 [PART A]
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL DSR I.No. 7.1.32. [PART A]
Supplying & erecting G.I. pipe ‘A’ class 50 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE. DSR I.no. 7.6.3 [PART A]
Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. DSR I.No. 7.6.5.[PART A]
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. DSR I.No. 7.6.9 [PART A]
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materils, testing & recording the results as per specification no. EA-EP. DSR I.No. 9.1.1. [PART A]
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP. DSR I.Np. 9.1.2. [PART A]
Supplying and erecting annealed bare copper wire of high purity of required sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws complete. DSR I.No. 9.2.4. [PART A]
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. DSR I.no. 9.2.3. [PART A]
S u p p l y i n g & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. dSR I.No. 13.15.1. [PART A]
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV. DSR I.No. 1.3.14. [PART B]
Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. DSR I.No. 2.4.5. [PART B]
Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB. DSR I.No. 5.3.1. [PART B]
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. DSR I.No. 6.1.19 [PART B]
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL DSR I.No. 7.1.27 [PART B]
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. DSR I.No. 7.6.9 [PART B]
Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL DSR I.No. 8.2.12. [PART B]
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT DSR I.No. 8.2.21 [PART B]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP. DSR I.No. 9.1.1. [PART B]
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP. DSR I.No. 9.1.4. [PART B]
Making cement concrete foundation including excavation ( 45 x 45 x 120 ) cm deep in 1:3:6 cement concrete, 20 to 25 mm stone metal, (45 x 45 x 45) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (for 6 m pole) DSR I.No. 16.3.2. [PART B]
Supplying, installing, testing and commissioning of 10 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 15 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card/chip for 5 years including net charges for RMS system, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG DSR I.No. 4.5.3. [PART C]
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. DSR I.No. 6.1.19 [PART C]
Supplying and erecting static energy meter with 3 x 240V 50 Hz. AC supply 10 to 60 A, ISI mark, accuracy class 1.0 with backlit LCD display, (Measuring and display Trivector, V, I, kW, PF, Hz, Last month history of kWh and MD in kW) with special features like TOD, Tamper logging, Optical Communication Port & Display in absence of Power & with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof PVC wires duly tested by electric supply company. DSR I.No. 6.3.3. [PART C]
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP. DSR I.No. 9.1.1. [PART C]
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. DSR I.no. 9.2.3. [PART C]
Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). DSR I.No. 16.3.7 [PART C]
MSEDCL Service Charges connection [PART C]
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf