Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹71.3 LAccepted-AOC JHARIA BENIGANJ HARDOI | BENIGANJ | HARDOI | UTTAR PRADESH | L1 | Accepted-AOC Qualify | |
| 2 | L2₹1.5 Cr+₹14.3 L (10.5%)Rejected-Finance | L2 | Rejected-Finance High amount quoted | |
| 3 | L3₹1.6 Cr+₹19.6 L (14.5%)Rejected-Finance | L3 | Rejected-Finance High amount quoted | |
| 4 | L4₹1.6 Cr+₹20.8 L (15.3%)Rejected-Finance | L4 | Rejected-Finance High amount quoted |
Tender Value
Refer Docs
EMD Value
₹11.8 L
Closing Date
25 May 2021, 2:30 pmClosed
Executive Engineer Electrical
GDA Office, Taramandal, Gorakhpur.
Please refer Tender documents.
2021_GORDA_585782_5
03/GDA/2021-22/28042021
Open Limited
Electrical Works
Item Rate
120 days
Golghar
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,800
₹11.8 L
28 Aug 2021
18 May 2021
25 May 2021
18 May 2021
25 May 2021
18 May 2021
18 May 2021 - 25 May 2021
Amount
Incoming - 100 Amp. MCCB-1 No (SI-811 c-ii/2018 SOR)
Outgoning - 63 Amp. MCCB-1 Nos, & 32 Amp. MCCB-2 Nos
(ii) Cat B. Pannel Cubicle Type
Incoming - 630 Amp. MCCB-1 No (SI-814 a-ii/2018 SOR)
Outgoning - 100 Amp. MCCB-5 Nos, & 63 Amp. MCCB-2 Nos
(ii) Cat B. Pannel Cubicle Type
Incoming - 1250 Amp/416 Volt ACB-1 No (SI-824 g-ii/2018 SOR)
Outgoning - 400 Amp. MCCB-3 Nos, & 200 Amp. MCCB-2 Nos
(ii) Cat B. Pannel Cubicle Type
Supply and fixing Following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. (SI. 807/2018)
40 A TPN (f-ii)
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below groung level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On durface the cable run shall be fixed on M.S. clamps etc. of sutible size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be proprely connected with the earth conductor by clamps etc. (SI.No 501/2018) MAKE- Havels, paly cab, KEI.
400 sqmmx3½ core S.I No. 501/T
150 sqmmx3½ core S.I No. 501/P
50 sqmmx3½ core S.I No. 501/L
25 sqmmx3½ core S.I No. 501/J
16 sqmmx4 core S.I No. 501/I
S/F of Plan or pin type copper tin plated cable socket (Lugs) (SI.No. 504/2018)
(ii) 400 sqmm S.I No. 504/O
(ii) 150 sqmm S.I No. 504/K
(ii) 50 sqmm S.I No. 504/G
(ii) 25 sqmm S.I No. 504/E
(ii) 16 sqmm S.I No. 504/D
(ii) 240 sqmm S.I No. 504/M
S/F of 100 mm dia G.I. pipe
Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50mm inner Dia 25mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Golvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30cm square C.I. frame with hinged cover & masonry housing. Make: As Approved in U.P. P.W.D., & C.P.R.I Certified. (SI.No.725 B/2018)
S/F of 2 Mtr. Hight cage fabricated with 3mm thick expanded metal fixed on 50mm x 50mm x 6mm angle iron frame having vertical members spaced at 1 to 1.25 mts and horizontal members spaced at 1 mt. The vertical members shall be grouted in floor and horizontal members in the wall to a depth of 300mm with ends forked etc. (SI. No.1142/2018)
Supply and fixing of LED street light Fitting having dia cast aluminium body and diffuser with driver set sutible for 45 Watt. To 50 Watt. Confirming to IP 66 protection complete in all respect. CAT-AA, (SI. No. 1421/2018) MAKE-Phlips, Bajaj, Paly Cab.
Supply and fixing of 6 mtr. GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Single arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&P completee in all respect. (SI. No.647/2018)
Supply and laying of 32x6 mm G.I. strip from earth eledctrode. (SI-717/2018
S/L of 3 core standered aluminium conductor XLPE (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cables confirming to I.S. 7098 (Part-II with latest amendments) II KV grade at a depth of 900mm below ground level over a cushion of 100mm thick fine river sand all around and protected with well burnt bricks on sides and on top put across. The armouring of cable shall be properly connected with earth conductor by clamps etc. MAKE- Havels, paly cab, KEI.
120 sq mm. SI No. 506 F/2018
S/M of outdoor type cable end termination with heat shhrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. 10.5.2 DSR 2018
(i) 120 sq mm.
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more then 17.5% in convenient section, joined with connectors, suspended from the ceilling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. (4.1 DSR 2018)
300mm width x 50mm depth x 1.6 mm thickness (4.1.4 DSR 18)
450mm width x 50mm depth x 2 mm thickness (4.1.6 DSR 18)
Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more then 17.5% in convenient section, joined with connectors, suspended from the ceilling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. (4.1 DSR 2018)
300mm width x 50mm depth x 1.6 mm thickness (4.2.4 DSR 18)
450mm width x 50mm depth x 2 mm thickness (4.2.6 DSR 18)
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more then 17.5% in convenient section, joined with connectors, suspended from the ceilling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. (4.3 DSR 2018)
300mm width x 50mm depth x 1.6 mm thickness (4.3.4 DSR 18)
450mm width x 50mm depth x 2 mm thickness (4.1.6 DSR 18)
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross with perforation not more then 17.5% in convenient section, joined with connectors, suspended from the ceilling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. (4.4 DSR 2018)
300mm width x 50mm depth x 1.6 mm thickness (4.4.4 DSR 18)
450mm width x 50mm depth x 2 mm thickness (4.4.6 DSR 18)
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more then 17.5% in convenient section, joined with connectors, suspended from the ceilling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. (4.5 DSR 2018)
300mm width x 50mm depth x 1.6 mm thickness (4.5.4 DSR 18)
450mm width x 50mm depth x 2 mm thickness (4.5.6 DSR 18)
S/L of HDPE (DWC) pipe for road crossing etc. (exept for cable support on pole) at a depth of 750mm below G.L. for L.T. calbe carriar as per direction of E/I. make Dura Line or Rack of following size .
(i) 90/76 mm OD/ID
S/F of HDPE (DWC) pipe coupler for jointing of pipe of size 90/76mm OD/ID make Dura line or Reck etc complete in all respect. As per E/I.
(i) 90/76 mm OD/ID
S/F of Auto cut 1 HP Electrick Mud pump for parking besment sump includin all complate. MAK- WILLO, CROMPTON GREVES.
Supply, instalation testing & commsing of 11/0.433KV, 630KVA CSS (Compact Sub-station) with dry type Transformer (Including plinths)
of 11kV, 630kVA Dry Type,CSS having Internal Arc Classification AB. 11kV, 630A, Al Busbar RMU, STC 20kA for 3 Sec, IAC 21kA for 0.1s and IAC Classification AB, RMU: 12KV RMU, LK, Non extensible, Indoor, 1 No. Of Cabling (K) and 1 no Mannual VCB feeder (L) ,with protection CT, Self Powered relay.Rated Voltage - 11kV, Rated power frequency withstand voltage - 28kV, Rated lightning impulse withstand voltage - 75kV, Rated current for Ring main feeder -630A, Rated short-time current (Ik)- 20kA / 3 Sec, Rated short making current - 52.5kA, Ambient temperature - (40 degree C). RMU Enclosure: IP3X (Indoor), RMU SF6 tank: IP67, RMU enclosure thickness: CRCA 2.0 mm. VCB: VCB with position ON-OFF only, three position switches ON-OFF-EARTH, Self powered relay for Overcurrent and earthfault protection with RS485 -
50KA, Manual Fixed , Air Circuit Breaker (ACB) with Microprocessor based Trip Unit (ETU) release for O/L, S/C, E/F. Bus Coupler: ACB: 1250A, 433V, 3P, 50Hz, 50KA, Manual Fixed , Air Circuit Breaker (ACB) with out Microprocessor based Trip Unit / release. Outgoing: MCCB: 800A, 433V, 4P, 50Hz Icu= 50KA, Fixed , Molded Case Circuit Breaker (MCCB) with LI release for O/L, S/C, MCCB: 400A, 433V, 4P, 50Hz Icu= 50KA, Fixed , Molded Case Circuit Breaker (MCCB) with LI release for O/L, S/C. Enclosure: Degree of protection : IP54 for enclosure ; IP23 for Trafo compartment Paint shade: Powder coated RAL 7032 for CSS except roof ; RAL 5021 for roof Enclosure material : CRCA, 2mm thick with bolted type K10 class enclosure with GI earthing busbar.The CSS Offered shall be as per the type tested. design submitted and approved by the Purchaser. ABB/ Siemens/ Schneider. MAKE- ABB, SIEMENS, SCHNEIDER,CROMPTON GREAVES.
11kV, 630A, LK, Non extensible, Indoor RMU LK-2 No. Of Cabling (K) and 1 no Mannual VCB feeder (L)
Transformer:
630KVA, 11KV/433V, 3 Phase, 50HZ, Dry Type Transformer - 1 Nos.
Bus-Coupler:
1250A, 433V, 4Pole, 50HZ, 50KA, Air Circuit Breaker - 1 Nos.
Incoming:
1250A, 433V, 4Pole, 50HZ, 50KA, Air Circuit Breaker, Microprocessor based - 1 Nos.
800A, 433V, 4Pole, 50KA, 50Hz, MCCB - 1 Nos
400A, 433V, 4Pole, 50KA, 50Hz, MCCB - 1 Nos.
S/F of factory wired internal LED food light luminaires with dia cast aluminium housing bult with driver set suitable for 170 to 200 Watt. Confirmming to IP 66 protection complete in all respect. CAT-AA (SI-1455/2018)
S/E of 125 KVA 3 Phase, 415 Volts Silent DG Set comprising of 415 Volts, standard make Three Phase Alternator mounted on a common base frame, complete with: (MAKE:-KIRLOSKAR, GREEN, JAKSON CUMMINS, MAHENDRA POWER)
Manual Control Panel
Fule Tank
Battery & Leads
Silencer - Residential
AVM Pads
First Fill of Lube Oil
Acoustic Enclosure
Construction of 125 KVA 3 Phase, 415 Volts Silent DG Set plinth of standard size. With all material required for proper completion of work as per PWD specification. (PSR)
H.V. PANEL (11 KV - VCB PANEL)
Supplying, installing, testing and commissioning of Indoor arc-proof Draw-Out Vacuum Circuit Breaker Panel, rated for 11kV, 1250Amp, 26.3kA/3-sec, Outgoing fully encapsulated pole VCB Panels and Bus PTs for each bus section, confirming to IEC 62271-200, Internal Arc Classified IAC AFLR – 26.3kA for 1sec, Accessibility Class LSC2B-PM Class, comprising of 1250Amp, continuous rated Copper busbars and droppers, 02nos. Rack-In-Rack-Out Handles, structure made from AluZinc/GI sheets to prevent corrosion and rusting.The complete panel incl. HT chamber shall be manufactured by approved OEM at its own facility, and same will be verified via stage/final inspection. License parter, system integrator, panel builder, half-panel concept is not allowed.The Board shall consist of following panels: (Make: ABB/Schneider/Semense)/Cromption Greaves
Offered relay shall have integrated arc protection which should be based on the detection of current and light simultaneously.
(i) Main Protection Relay shall be numerical IED Relay confirming to IEC60255, having microprocessor based protection scheme for tripping the breaker on various faults like. (1) over-current or earth-fault in any of the three phases, (2) negative sequence currents due to line-to-line or conductor-break faults, (3) thermal runaway in cables monitored via simulated temperature controle. (4) circuit-breaker-failure alarm, (5) tripping-circuit-failures and interpanel tripping/blocking signals via GOOSE based peer-to-peer communication, on IEC61850 protocol.The relay shall be fully integrated with the feeder, internally capturing feeder statuses and Line-Currents and display the same locally on a built-in back-lit LCD screen as a Single-Line-Diagram with current measurements and suitably labelled status LEDs. TCP/IP based WebHMI shall be integrated part of relay for remote setting without requiring any special relay software. Offered relay shall have integrated arc protection which should be based on the detection of current and light simultaneously.
(ii) Metering Equipment incl. 01x Digital Ammeter (Acc.Cl.0.5), 01 x Tri-VectorMeter (Acc.Cl.0.5) (iii) Indications - LED for Breaker ON/OFF/TRIP/Spring-Charged, 04-Window Annunciator with Hooter (iv) Control Equipment incl. 01 x TNC Switch, 01 x Emergency Trip Push Button, MCBs for AC/DC isolation as required (v) Other accessories incl. Space Heater with thermostat for breaker, busbar, LV panel and cable chamber, 3-Pin socket with switch, CFL lamp.
S/F of Double pole structure of S.P.-55 11Mtr. Long S.T. pole 11.00mtr. Long complete with all accassories including grouting & making plinth above 20cm G.L. in 1:3:6 C.C. with excavation and back filling etc. complete in all respect.
Laying of parller 11 kv 3x120 sq mm cable HDD methed as per respo norms (UPPCL).
INDIA SUPPY CORPORATION
NOVA CONSTRUCTION
Dharmendra Kumar Srivastava
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Restricted Tender
This is a Open Limited tender. Documents are accessible only to bidders authorized by the issuing authority on the government portal.
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .