Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹81,167Qualified Make: BPL
Model: BPL Cardiart 8108view 16 90 2ND FLOOR SUBHASH NAGAR NEW DELHI WEST DELHI DELHI 110027 | WEST DELHI | DELHI | 110027 | Make: BPL
Model: BPL Cardiart 8108view | L1 | Qualified | |
| 2 | L2₹84,500+₹3,333 (4.11%)Qualified Make: BPL
Model: BPL Cardiart 8108view WEST VINOD NAGAR DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110092 | EAST DELHI | DELHI | 110092 | Make: BPL
Model: BPL Cardiart 8108view | L2 | Qualified | |
| 3 | L3₹84,900+₹3,733 (4.60%)Qualified Make: BPL Medical Technologies Pvt Ltd
Model: BPL Cardiart 8108 ASC E524 ACCORD SALES COROPORATION OFFICE NO 205 2ND FLOOR BUILDING NO 19 B VEER SAVARKAR BLOCK NEW DELHI 110092 965 | EAST DELHI | DELHI | 110092 | Make: BPL Medical Technologies Pvt Ltd
Model: BPL Cardiart 8108 ASC | L3 | Qualified | |
| 4 | Disqualified Make: BPL
Model: BPL | Make: BPL
Model: BPL | - | Disqualified | |
| 5 | Disqualified Make: BPL
Model: Cardiart 8108 view- BPL 0 SAHU BHAWAN 413 23 CHADHAI MAHU LAL CHAUPATIYAN ROAD CHOWK CHOWK LUCKNOW UTTAR PRADESH 226003 | LUCKNOW | UTTAR PRADESH | 226003 | Make: BPL
Model: Cardiart 8108 view- BPL | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
11 Aug 2018, 12:00 pmClosed
electrocardiography ekg/ecg units Electrocardiography Ekg/ecg Units ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values FEATURES Mobility
portability Protective splashproof case for clean storage and safe transport - Heart rate measurement range to be at least 30 to 250 bpm
with accuracy better than ± 5 bpm yes - Heart rate trend display of at least previous 24 hours yes - In built Software and/or standard of communication yes - Heat Dissipiation: Should maitain nominal Temp and the heat should be disbursed through a exhaust cooling fan yes - User interface manual - Noise Lavel (dba) - - Electrical protection provided by fuses in both live and neutral yes - 1/4 supply lines Operating condition: Capable of operating continuously in ambient temperature of 0 to 50 deg C and relative humidity of 15 to 90% in ideal circumstances yes - Arrhythmia detection facility required; minimum gradation of 1 bpm yes - Functional requirements: electricity;AC-powered; bedside device designed to continuously detect
measure
and display a patient’s electrocardiogram through leads and sensors attached to the patient
it also typically display heart rate
the device is typically equipped with audible and/or visual alarms that are triggered when the patien's parameters drop below or exceed pre-set limits: Continuous display of patient ECG and heart rate on screen
Allows display of single
5 lead ECG or simultaneous display of at least 5 waves selected from up to 12 points Operator can set audiovisual alarm levels for low or high heart rate Operates from mains voltage or from internal rechargeable battery yes - Power consumption - - weight - - Power cable length (meter) 3 METER OR MORE - Display must allow easy viewing in all yes - 2/4 ambient light levels Audiovisual alarms required: high and low heart rate; operator variable settings
cardiac arrhythmia
sensor/wire disconnected
low battery yes - STANDARDS AND SAFETY
CERTIFICATIONS Certification(s) ISO 13485 Certificate For Quality Standard
CE Approved product - MISCLANEOUS Warranty (years) 5 5.0 power input and frequency 220 To 240V
50 Hz AC - Certificate of Calibration and Inspection to be provided YES - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Arghya Sengupta 110062
Commandant Base Hospital
ITB Police
Tigri Camp 1 21
372047
GEM/2018/B/52688
electrocardiography ekg/ecg units
21 days
Delhi; South Delhi
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| electrocardiography ekg/ecg units Electrocardiography Ekg/ecg Units ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values FEATURES Mobility | - | - | - |
| portability Protective splashproof case for clean storage and safe transport - Heart rate measurement range to be at least 30 to 250 bpm | - | - | - |
| with accuracy better than ± 5 bpm yes - Heart rate trend display of at least previous 24 hours yes - In built Software and/or standard of communication yes - Heat Dissipiation: Should maitain nominal Temp and the heat should be disbursed through a exhaust cooling fan yes - User interface manual - Noise Lavel (dba) - - Electrical protection provided by fuses in both live and neutral yes - 1/4 supply lines Operating condition: Capable of operating continuously in ambient temperature of 0 to 50 deg C and relative humidity of 15 to 90% in ideal circumstances yes - Arrhythmia detection facility required; minimum gradation of 1 bpm yes - Functional requirements: electricity;AC-powered; bedside device designed to continuously detect | - | - | - |
| measure | - | - | - |
| and display a patient’s electrocardiogram through leads and sensors attached to the patient | - | - | - |
| it also typically display heart rate | - | - | - |
| the device is typically equipped with audible and/or visual alarms that are triggered when the patien's parameters drop below or exceed pre-set limits: Continuous display of patient ECG and heart rate on screen | - | - | - |
| Allows display of single | - | - | - |
| 5 lead ECG or simultaneous display of at least 5 waves selected from up to 12 points Operator can set audiovisual alarm levels for low or high heart rate Operates from mains voltage or from internal rechargeable battery yes - Power consumption - - weight - - Power cable length (meter) 3 METER OR MORE - Display must allow easy viewing in all yes - 2/4 ambient light levels Audiovisual alarms required: high and low heart rate; operator variable settings | - | - | - |
| cardiac arrhythmia | - | - | - |
| sensor/wire disconnected | - | - | - |
| low battery yes - STANDARDS AND SAFETY | - | - | - |
| CERTIFICATIONS Certification(s) ISO 13485 Certificate For Quality Standard | - | - | - |
| CE Approved product - MISCLANEOUS Warranty (years) 5 5.0 power input and frequency 220 To 240V | - | - | - |
| 50 Hz AC - Certificate of Calibration and Inspection to be provided YES - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Arghya Sengupta 110062 | - | - | - |
| Commandant Base Hospital | - | - | - |
| ITB Police | - | - | - |
| Tigri Camp 1 21 | - | - | - |
Exempted
11 Aug 2018
24 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_372047.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .