Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹16.9 Laccepted-aoc | accepted-aoc |
Tender Value
₹16.2 L
EMD Value
₹41,000
Closing Date
10 Sept 2026, 5:30 pmClosed
Minor Irrigation Department
raghuram
Rejuvenation of LIS Benakal in Ballari Taluk & Dist.
MI/2026-27/LI/WORK_INDENT12577
MI/2026-27/LI/WORK_INDENT12577
Open
Lift Irrigation Scheme
Electronic Documents, First(One Cover)
Minor Irrigation Division Bellary
4 documents required · 4 mandatory
₹500
₹41,000
10 Sept 2026
1 Sept 2026
9 Sept 2026
Rejuvenation of LIS Benakal in Ballari Taluk & Dist.
Removing silt and slush from dewatering pit, draft tube, tail race pond, cooling towers etc., by mechanical means/ manually including multiple handling wherever necessary and stacking etc., complete w...
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, cauti...
Providing S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work sit...
Laying,Lowering and jointing of S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class ,rolling and lowering into trenches, laying true to line and level at both destinations and jointing of...
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ra...
Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 m² and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface w...
Manufacturing, supplying, laying in position, aligning, jointing, testing and commissioning of electric resistance welded /submerged arc weldedmild steel (Fe-410 grade) manifold pipe system of s...
Providing and fixing kinetic AIR VALVE of PN 16.0 for automatic discharge of accumulate air during working condition, conforming to IS 14845/ EN 1074-4. Body and bonnet of DI conforming to IS-1865 of...
Manufacturing, providing, trasporting, rolling, lowering, laying,jointing and commissioning of ERW (Electric Resistance Welded)/
SAW (Submerged Arc Welded) MS pipes of Outer dia (Fe-410 grade) confo...
Providing, fabricaing and fixing at site various diameters of MS Flanges as per IS standards to fix sluice valves as per sketch. The rate to include cost of all materials, labour, consumables, hire ch...
Removing and refixing the 230/415 v 50 hz I phase/III phase suitable capacity suitable speed horizontal foot mounted screen protected drip proof continous rated monoblock/squrrel cage induction motor ...
Providing Ball bearing as per ISI specifiction with guarantee period of not less than 12 months etc.., complete with all lead and lifts including loading and unloading and as per specifiction with th...
Providing thrust bearing as per ISI specifiction with guarantee period of not less than 12 months etc.., complete with all lead and lifts including loading and unloading and as per specifiction with...
Removing & refixing the pump after repairing of existing horizontal mounting/ monoblock pump with following spares, etc. including
aligning of pump with reference to motor & running the pump on load....
Man Power: Engaging Pump operator for Pump Operation at Jackwell for engaging one operator for day and one operator for night
Engaging watchman for watch and ward of LIS
Consumables Transformer oil-@ Jackwell
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
KW-1 Benakal.doc
Tender Document • 21.84 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .