Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAccepted-AOC | ₹18.4 L Quoted ₹19.4 L | L1 | Accepted-AOC L1 |
| 2 | L2₹20.2 L+₹76,013.74 (3.91%)Rejected-Finance GROUND FLOOR TRACTOR MARKET KAITHAL ROAD ASSANDH KARNAL HARYANA 132039 | KARNAL | HARYANA | 132039 | ₹20.2 L+₹76,013.74 (3.91%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹20.8 L+₹1.4 L (7.14%)Rejected-Finance 622 A STREET NO 3 FIRST FLOOR SHAKTI NAGAR BATHINDA 151001 PUNJAB | BATHINDA | PUNJAB | 151001 | ₹20.8 L+₹1.4 L (7.14%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹21.7 L+₹2.3 L (11.7%)Rejected-Finance 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | ₹21.7 L+₹2.3 L (11.7%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹21.9 L+₹2.5 L (12.9%)Rejected-Finance | ₹21.9 L+₹2.5 L (12.9%) | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | Aman Enterprises L7 | AABIA CONSTRUCTION L8 | M/s Luxmi Constructions L4 | SWARN SINGH AND CO. L2 | Rasvinderpalandco L1 | Truly Technos LLP L3 | REYANSH GARG AND COMPANY L5 | KAY VEE CONSTRUCTIONS L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installing testing and commissioning in replacement of factory made and tested (Including CPRI test certified) outdoor type floor mounted LT panel board, cubical type suitable for 415 Volts 3 phase, 4 wire 50Hz, Ac supply system having busbar chamber with insulated AL busbar of rating 1.5 times the incomer MCCB for phase installed on porcelin/ SMC insulators. The panel shall be dust and vermin proof IP-64 class protection and made out of 3.15 mm thick CRCA MS sheet and angle iron frame 40x 40x 6mm thick frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coat of red oxide primer, front and back opening type with approaches for cable entry with double door shutter and locking arrangements including internal wiring with PVC insulated stranded copper conductor cable FRLS IS 694 sheathed 1100V grade of appropriate size comprising of following, complete all as specified and directed by Engineer in charge. | 1 | EACH JOB | 3,55,000 ₹3,55,000 | 4,22,000 ₹4,22,000 | 2,61,000 ₹2,61,000 | 2,90,000 ₹2,90,000 | 2,62,500 ₹2,62,500 | 2,55,000 ₹2,55,000 | 2,85,000 ₹2,85,000 | 2,25,000 ₹2,25,000 Lowest |
| 2.00INCOMING- (i) Mains MCCB 4 pole 500 Amps 50 KA with adjustable setting, 415 Volts with breaking capacity 36 KA. -01 No. (ii) On load Changeover switch panel mounted with all connections - 01 No. (iii) Digital type voltmeter 0-500 volts and with selector switch-01 No. (iv) Digital Amp meter with CTs & built in selector switch-01 No. (v) Indication lamp RYB-01 Set. OUTGOING- (i) MCCB 4 pole 315Amps, 415 Volts with breaking capacity 25 KA.-01 No. (ii) MCCB 4 pole 200 Amps, 415 Volts with breaking capacity 25 KA.-02 No. (iii) MCCB 4 pole 160 Amps, 415 Volts with breaking capacity 25 KA.-01 No. (iv) MCCB 4 pole 63 Amps, 415 Volts with breaking capacity 16 KA.-02 No. | |||||||||||
| 3.00 | Supply, installing testing and commissioning in replacement of factory made and tested (Including CPRI test certified) outdoor type floor mounted LT panel board, cubical type suitable for 415 Volts 3 phase, 4 wire 50Hz, Ac supply system having busbar chamber with insulated AL busbar of rating 1.5 times the incomer MCCB for phase installed on porcelin/SMC insulators. The panel shall be dust and vermin proof IP-64 class protection and made out of 3.15 mm thick CRCA MS sheet and angle iron frame 40x 40x 6mm thick frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coat of red oxide primer, front and back opening type with approaches for cable entry with double door shutter and locking arrangements including internal wiring with PVC insulated stranded copper conductor cable FRLS IS 694 sheathed 1100V grade of appropriate size, complete all as specified and directed by Engineer in charge. | 1 | EACH JOB | 3,00,000 ₹3,00,000 | 3,35,000 ₹3,35,000 | 2,52,000 ₹2,52,000 | 2,65,000 ₹2,65,000 | 1,55,000 ₹1,55,000 | 1,20,000 ₹1,20,000 Lowest | 2,35,000 ₹2,35,000 | 2,25,000 ₹2,25,000 |
| 4.00INCOMING:- (i) Mains MCCB 4 pole 315Amps 50 KA with adjustable setting, 415 Volts with breaking capacity 36 KA. -01 No. (ii) On load Changeover switch panel mounted with all connections - 01 No. (iii) Digital type voltmeter 0-500 volts and with selector switch-01 No. (iv) Digital Amp meter with CTs & built in selector switch-01 No. (v) Indication lamp RYB-01 Set. OUTGOING:- (i) MCCB 4 pole 63Amps, 415 Volts with breaking capacity 25 KA.-01 No. (ii) MCCB 4 pole 200 Amps, 415 Volts with breaking capacity 25 KA.-02 No. (iii) MCCB 4 pole 160 Amps, 415 Volts with breaking capacity 25 KA.-01 No. (iv) Spare compartment for MCCB - 01 Nos | |||||||||||
| 5.00 | Dismantling or Taking down old unserviceable ACSR conductors from the poles complete with stay assembly, complete all as specified and directed by Engineer in charge. | 1.5 | QUINTAL | 500 ₹750 | 1,500 ₹2,250 | 900 ₹1,350 | 5,000 ₹7,500 | 200 ₹300 Lowest | 200 ₹300 Lowest | 500 ₹750 | 1,500 ₹2,250 |
| 6.00 | Taking down old unserviceable GI wire, complete all as specified and directed by Engineer in charge. | 0.8 | QUINTAL | 500 ₹400 | 450 ₹360 | 900 ₹720 | 3,500 ₹2,800 | 200 ₹160 Lowest | 200 ₹160 Lowest | 500 ₹400 | 1,000 ₹800 |
| 7.00 | Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m, complete all as specified and directed by Engineer in charge. | 0.9 | QUINTAL | 500 ₹450 | 600 ₹540 | 900 ₹810 | 3,500 ₹3,150 | 200 ₹180 Lowest | 200 ₹180 Lowest | 500 ₹450 | 500 ₹450 |
| 8.00 | Taking down old unserviceable Clamps including Nut, bolt washers of any size, complete all as specified and directed by Engineer in charge. | 2 | KILO GRAM | 40 ₹80 | 50 ₹100 | 54 ₹108 | 40 ₹80 | 200 ₹400 | 30 ₹60 Lowest | 500 ₹1,000 | 500 ₹1,000 |
| 9.00 | Taking down old unserviceable insulators of any size/type, complete all as specified and directed by Engineer in charge. | 54 | EACH | 40 ₹2,160 | 50 ₹2,700 | 18 ₹972 | 30 ₹1,620 | 5 ₹270 Lowest | 200 ₹10,800 | 100 ₹5,400 | 400 ₹21,600 |
| 10.00 | Taking down old unserviceable LT panel of any size/type, complete all as specified and directed by Engineer in charge. | 1 | EACH | 600 ₹600 | 550 ₹550 | 2,700 ₹2,700 | 2,000 ₹2,000 | 500 ₹500 Lowest | 3,000 ₹3,000 | 500 ₹500 Lowest | 2,000 ₹2,000 |
Tender Value
Refer Docs
EMD Value
₹48,600
Closing Date
31 Jul 2025, 6:00 pmClosed
GE (AF) BHISIANA
GE (AF) BHISIANA PIN - 151201
CONVERSION OF OVER HEAD ELECTRIC WIRES INTO UNDERGROUND ELECTRIC WIRES AND ALUMINIUM ELECTRIC WIRE INTO COPPER WIRE IN KV NO 03 AT AF STN BHISIANA
2025_MES_717801_1
GE/BHI/CAP-01/2025-26
Open Tender
Civil Works
Item Rate
183 days
GE (AF) BHISIANA
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (AF) BHISIANA
₹48,600
Yes
1 Sept 2025
1 Jul 2025
2 Aug 2025
1 Jul 2025
31 Jul 2025
17 Jul 2025
1 Jul 2025 - 8 Jul 2025
Amount
Supply, installing testing and commissioning in replacement of factory made and tested (Including CPRI test certified) outdoor type floor mounted LT panel board, cubical type suitable for 415 Volts 3 phase, 4 wire 50Hz, Ac supply system having busbar chamber with insulated AL busbar of rating 1.5 times the incomer MCCB for phase installed on porcelin/ SMC insulators. The panel shall be dust and vermin proof IP-64 class protection and made out of 3.15 mm thick CRCA MS sheet and angle iron frame 40x 40x 6mm thick frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coat of red oxide primer, front and back opening type with approaches for cable entry with double door shutter and locking arrangements including internal wiring with PVC insulated stranded copper conductor cable FRLS IS 694 sheathed 1100V grade of appropriate size comprising of following, complete all as specified and directed by Engineer in charge.
Supply, installing testing and commissioning in replacement of factory made and tested (Including CPRI test certified) outdoor type floor mounted LT panel board, cubical type suitable for 415 Volts 3 phase, 4 wire 50Hz, Ac supply system having busbar chamber with insulated AL busbar of rating 1.5 times the incomer MCCB for phase installed on porcelin/SMC insulators. The panel shall be dust and vermin proof IP-64 class protection and made out of 3.15 mm thick CRCA MS sheet and angle iron frame 40x 40x 6mm thick frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coat of red oxide primer, front and back opening type with approaches for cable entry with double door shutter and locking arrangements including internal wiring with PVC insulated stranded copper conductor cable FRLS IS 694 sheathed 1100V grade of appropriate size, complete all as specified and directed by Engineer in charge.
Dismantling or Taking down old unserviceable ACSR conductors from the poles complete with stay assembly, complete all as specified and directed by Engineer in charge.
Taking down old unserviceable GI wire, complete all as specified and directed by Engineer in charge.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m, complete all as specified and directed by Engineer in charge.
Taking down old unserviceable Clamps including Nut, bolt washers of any size, complete all as specified and directed by Engineer in charge.
Taking down old unserviceable insulators of any size/type, complete all as specified and directed by Engineer in charge.
Taking down old unserviceable LT panel of any size/type, complete all as specified and directed by Engineer in charge.
Supply, laying and testing of cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured LT 1100 volts grade (Heavy duty) with stranded aluminium standard conductor of cross section area 240 Sq mm 3.5 Core( Main Cable From Transformer to LT panel ), complete all as specified and directed by Engineer in charge.
Supply, laying and testing of cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured LT 1100 volts grade (Heavy duty) with stranded aluminium standard conductor of cross section area 150 Sq mm 3.5 Core, complete all as specified and directed by Engineer in charge.
Supply, laying and testing of cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured LT 1100 volts grade (Heavy duty) with stranded aluminium standed conductor of cross section area 50 Sq mm 3.5 Core, complete all as specified and directed by Engineer in charge.
Supply, laying and testing of cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured LT 1100 volts grade (Heavy duty) with stranded aluminium standed conductor of cross section area 70 Sq mm 3.5 Core, complete all as specified and directed by Engineer in charge.
Supply, laying and testing of cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured LT 1100 volts grade (Heavy duty) with stranded aluminium standed conductor of cross section area 10 Sq mm 4 Core, complete all as specified and directed by Engineer in charge.
M&L for Excavation in trenches not exc. 1.5 m wide and not exceeding 1.5m depth for foundation of poles/laying of cables/ stay/ strut etc not exceeding 10 Sq m on plan and getting out in soft/loose soil, complete all as specified and directed by Engineer in charge.
M&L for Returning, filling including spreading, levelling watering and well ramming in layers not exceeding 25 cm, complete all as specified and directed by Engineer in charge.
M&L for Removing excavated material (soil) n.exc 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed by Engineer in charge.
M&L for Fazilka river sand as in sand cushioning to under ground cable including punning down of thickness 180mm sand in layers, complete all as specified and directed by Engineer in charge.
S&F reinforced precast concrete cable cover LV, Type I, flat, size 250mm x 150mm x 40mm, complete all as specified and directed by Engineer in charge.
M&L for making bore below the road for crossing the GI pipe light grade 50 mm dia for cable protection and fill the putty on both sides of the GI pipe after crossing the armoured cable to avoid the water inside, complete all as specified and directed by Engineer in charge.
M&L for GI pipe 50 mm dia., 'light grad', galvanised, with all fitting; laid in trenches, complete all as specified and directed by Engineer in charge.
M&L for earthing with steel earth plate electrode of size 60cm x 60 cm x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less tha 1.5 mtr deep below normal grund level connected to galvanized iron strip size 32 x 6 mm as earthing lead by means of nuts, bolts and washers of steel after wlding of GIstrip to earth electrode to the full length of earth plate, 40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover ofsize 30x30 cm made of RCC 1:3: with suitable handle, angle iron frame made of angle iron of size 40x40x4m, adequate qty of charcoal dust and salt layers all around the earth plate and filling of vegetables soil to the remaining 10% removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I, complete all as specified and directed by Engineer in charge.
Taking down carefully copper/ aluminium point wiring (light fan socket or power) complete along with fittings such as switches, ceiling roses, Pendants regulators Tube fittings and other Kits & fittings/ conduit from surface/ wall. Removing the material from work site and making good the disturbed portion/ surface of wall/ floor/ ceiling etc by using cement mortar and colour/ white wash to match with the existing surface/ location, complete all as specified and directed by Engineer in charge. (Note :- Serviceable fitting/ fixtures will be reused and refixing in the work.
M&L for point wiring with FRLS PVC insulated unsheathed multi-stranded copper conductor 1.5 Sq.mm (nominal area) single core cable 1100 Volt grade drawn in and including rigid non metallic concealed PVC Conduit of suitable size (not less than 20 mm) on wall, surface of ceiling with all fittings, such as tee, bend, elbow, socket etc including pressed steel sunken boxes (Terminal boxes) with earth dolly, duly galvanised, with white shade frame & cover plate of suitable module for modular switch or sockets including FRLS PVC insulated unsheathed stranded copper conductor 1.5 Sq.mm (nominal area ) single core cable as earth continuity conductor to common earth and connected to earth dolly for the following, complete all as specified and directed by Engineer in charge. Notes:- (i) Cost of Pressed steel Terminal Boxes and modular Top cover plate shall be included in point wiring. (ii) Wiring shall be done as per colour code in IS for phase, neutral and earth. (iii) Cost of Eye/bottle thimbles used for connection in switches/sockets & MCBs in DBs shall deemed to be included in the unit rate quoted for this item.
(a) One light/ fan point controlled by one 1-way switch.
(b) One 3/5 pin socket outlet, 5 Amp on independent board.
(c) One 3/5 pin socket outlet, 5 Amp on same board.
M&L for point wiring with FRLS PVC insulated unsheathed multi-stranded copper conductor 4 Sq.mm (nominal area ) single core cable 1100 Volt grade drawn in and including rigid non metallic concealed PVC Conduit on wall , surface of ceiling with all fittings, such as tee, bend, elbow, socket etc including pressed steel sunken boxes (Terminal boxes) with earth dolly, duly galvanised, with white shade frame & cover plate of suitable module for modular switch / or sockets including FRLS PVC insulated unsheathed stranded copper conductor 4 Sq.mm (nominal area ) single core cable as earth continuity conductor to common earth and connected to earth dolly, complete all as specified and directed by Engineer in charge.
M&L for point wiring with FRLS PVC insulated unsheathed multi-stranded copper conductor 2.5 Sq.mm (nominal area ) single core cable 1100 Volt grade drawn in and including rigid non metallic concealed PVC Conduit on wall, surface of ceiling with all fittings, such as tee, bend, elbow, socket etc including pressed steel sunken boxes (Terminal boxes) with earth dolly, duly galvanised, with white shade frame & cover plate of suitable module for modular switch / or sockets including FRLS PVC insulated unsheathed stranded copper conductor 2.5 Sq.mm (nominal area ) single core cable as earth continuity conductor to common earth and connected to earth dolly, complete all as specified and directed by Engineer in charge. Notes:- (i) Cost of Pressed steel Terminal Boxes and modular Top cover plate shall be included in point wiring. (ii) Wiring shall be done as per colour code in IS for phase, neutral and earth. (iii) Cost of Eye/bottle thimbles used for connection in switches/sockets & MCBs in DBs shall deemed to be included in the unit rate quoted for this item.
Dismantling or Taking down existing unserviceable sub main wiring from batten/ conduit of any size all as directed and Removing the material from work site and making good the disturbed portion/ surface of wall/ floor/ ceiling etc by using cement mortar and colour/ white wash to match with the existing surface/ location, complete all as specified and directed by Engineer in charge.
M&L for sub main surface wiring with PVC insulated unsheathed copper conductor cable of size 10 Sqmm single core through concealed rigid non-metallic PVC conduit of suitable size (Not less than 25 mm dia) in wall and surface of ceiling including 10 Sqmm PVC insulated unsheathed copper conductor cable for continuous earthing form main earth dolly including making good the disturbed potion of wall, complete all as specified and directed by Engineer in charge. Note:- Two run of 10 Sqmm copper cable one run of 10 Sqmm copper cable and PVC conduit will be measured as a single length)
M&L for sub main surface wiring with PVC insulated unsheathed copper conductor cable of size 6 Sqmm single core through concealed rigid non-metallic PVC conduit of suitable size (Not less than 25 mm dia) in wall and surface of ceiling including 6 Sqmm PVC insulated unsheathed copper conductor cable for continuous earthing form main earth dolly including making good the disturbed potion of wall, complete all as specified and directed by Engineer in charge. Note:- Two run of 6 Sqmm copper cable one run of 6 Sqmm copper cable and PVC conduit will be measured as a single length.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp,240 V, complete all as specified and directed by Engineer in charge.
S&F for replacement of Switch Modular type, 6 Amp, 240 Volts , one way, complete all as specified and directed by Engineer in charge.
S&F for replacement of Switch Modular type, 16 Amp,240 Volts , one way, complete all as specified and directed by Engineer in charge.
S&F for replacement of Socket outlet, Modular type, 6 Amp, complete all as specified and directed by Engineer in charge.
S&F for replacement of Socket outlet, Modular type, 6 &16 Amp, complete all as specified and directed by Engineer in charge.
S&F for replacement of Fan regulator, modular type 120 W-2 Module electronic step type, complete all as specified and directed by Engineer in charge.
SWARN SINGH AND CO. (BID ID -3370201)
Truly Technos LLP (BID ID -3368698)
M/s Luxmi Constructions (BID ID -3370230)
REYANSH GARG AND COMPANY (BID ID -3369525)
KAY VEE CONSTRUCTIONS (BID ID -3370361)
Aman Enterprises (BID ID -3367908)
AABIA CONSTRUCTION (BID ID -3369949)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .