Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 LAccepted-AOC NARAN PALLY PURBO BARDHAMAN PIN 713 101 | PURBA BARDHAMAN | WEST BENGAL | 713101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹22.6 L+₹9,637 (0.43%)Rejected-Finance 26 3 R K BHATTACHARJEE LANE BERHAMPORE MURSHIDABAD | BERHAMPORE | MURSHIDABAD | WEST BENGAL | L2 | Rejected-Finance L2 | |
| 3 | L3₹22.8 L+₹36,070 (1.61%)Rejected-Finance NATUNGANJ RAJBATI WEST GATE BURDWAN | BURDWAN | BURDWAN | WEST BENGAL | L3 | Rejected-Finance L3 | |
| 4 | L4₹22.9 L+₹43,463.92 (1.94%)Rejected-Finance 448 MUZAFFAR AHMED STREET KOLKATA 700 016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | L4 | Rejected-Finance L4 | |
| 5 | L5₹23.5 L+₹99,997 (4.45%)Rejected-Finance 85 KALNA ROAD BURDWAN | BURDWAN | PURBA BARDHAMAN | WEST BENGAL | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
11 Sept 2020, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, Asansol Electric
Office of the Executive Engineer, Asansol Electrical Division, PWD, near Polo Ground, Asansol 713304
Special renovation and modernization of E I for boys hostel at ITI Durgapur, Dist Paschim Bardhaman
2020_WBPWD_294453_1
WBPWD/EE/AED /eNIQ-07/2020-21
Open Tender
ELECTRICAL WORKS M/R
Item Rate
DURGAPUR
Please refer Tender documents.
4 documents required · 4 mandatory
₹60,000
30 Jun 2021
28 Aug 2020
14 Sept 2020
28 Aug 2020
11 Sept 2020
31 Aug 2020
180 days
Amount
S/Laying 1.1 kv grade 4 core 50 sq.mm XLPE/PVC insulated and sheathed, armoured cable with Al.conductor (HAVELLS/POLYCAB/ GLOSTER/R R KABEL) in following manner as to GS.(From Source to VTPNDB).
a)Through UG Trench.
b) Through wall at an average depth of 75 mm.
S/Laying 1.1 kv grade 4 core 25 sq.mm XLPE/PVC insulated and sheathed, armoured cable with Al.conductor (HAVELLS/POLYCAB/ GLOSTER/R R KABEL) in following manner as per GS.
a) Through UG trench
b)Through wall at an average depth of 75mm.
BDB,PBDB, MAIN SWITCHES & other related items S&F 8 way Vertical TPN PBDB with 3 phase in coming & TP/SP outgoings, as follows with vertical type busbar system, in SS enclosure (IP-43 protection) (Make:- Legrand/ABB/L&T) double door comprising of neutral link incl. & provision for earthing attachment concealed in wall after cutting the brick wall and mending good the damages to original finish incl. interconnection with suitable size of copper wires and earthing attachment. Incoming-415V, 10KA, 125 A,4 pole MCCB ----1 no Outgoing- 415V, 10KA, 63A T.P MCB C curve ---8 (make: Legrand/Schneider/Siemens)
Supplying & fixing 415V, 6-32A per way ,4 way TPN MCBDB with SS enclosure double door with IP 42/43 protection with 63 A FP isolators as incomer and 12 Nos. 6-32A SPMCBs ( 'C' Curve , 10kA ) as outgoing ,concealed in wall after cutting the wall & mending good the damages to original finish incl. inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make-Legrand/Schneider/Siemens)
Supplying & fixing 250V,6-10A per way , SPN MCBDB with SS enclosure double door with IP42/43 protection with DP isolators as incomer and SPMCBs ( 'C' Curve , 10kA ) as outgoing ,concealed in wall after cutting the wall & mending good the damages to original finish incl. inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make-Legrand/Schneider/Siemens ), 2+12 way Enclosure, 607712, 40A DP Isolator,10 Nos. SPMCB.
Distribution wiring Supply and drawing 2x6 sqmm +1x4 Sqmm PVC/Cu wire in prelaid polythene pipe embedded in wall or PVC Rigid Conduit on wall from PBDB to SPNDB incl. connection as to G S.( Havells/ Finolex/ Polycab/ R R Kabel - Brand approved by EIC)
Supply and drawing 2 X 2.5 Sqmm + 1X 1.5 Sqmm PVC/Cu in in 2 prelaid polythene pipe embedded in wall or PVC Rigid Conduit on wall from BDB to 5/15Amp Plug point incl. connection mending good the damages as to G S. ( Havells/ Finolex/ Polycab/ R R Kabel - Brand approved by EIC)
Supply and drawing 2 X 1.5 Sqmm + 1X 1.5 Sqmm PVC/Cu in prelaid polythene pipe embedded in wall or PVC Rigid Conduit on wall from BDB to Board Plug point incl. connection mending good the damages as to G S. ( Havells/ Finolex/ Polycab/ R R Kabel - Brand approved by EIC)
Supply and drawing 19 mm dia 3 mm thick polythene pipe without ECC embedded in wall after cutting the with electric cutting machine and mending good the damages as to original finish as to GS.
Supply & Fixing 20 mm dia PVC rigid Conduit pipe ( Precision make ) on wall and mending good the damages as to original finish as to GS.
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire ( Havells/ Standard/Finolex/ Polycab/ R R Kabel - Brand approved by EIC) mainly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion through MS angle structure & horizontal run avobe false ceiling / under the false ceiling ) and in19 mm bore, 3mm thick polythene pipe [for vertical run/ drop concealed manner) embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with modular type switch ( EIC approved make) fixed on G I Modular type switch board with top cover plate flushed in wall complete with 2 no. “Ph & N” copper bar incl. (175x100x65) mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish ( vertical drop concealed & switch board concealed).
(a) Avg.Run- 8 Mtr
(b) Avg.Run- 10 Mtr
On board plug point with 5A 3/5 pin modular type plug socket
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire ( Havells/ Standard/Finolex/ Polycab/ R R Kabel) brand approved by EIC) mainly in 19mm dia 3 mm thick polythene pipe embedded in wall and PVC Rigid Conduit (precision make ) only for ceiling M S structure [for ceiling portion avobe false ceiling } with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with modular type switch ( EIC approved make) fixed on G I Modular type switch board with top cover plate flushed in wall complete with 2 no. “Ph & N” copper bar incl. (175x100x65) mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish ( ( PVC rigid conduit on ceiling portion and remaining portion concealed manner).
(a) Avg.Run- 8 Mtr
(b) Avg.Run- 10 Mtr
Plugs & sockets/power unit Supplying & fixing of 250 V 2 X 6 A modular type Switch, 2x6A 5 pin plug socket (make:Approve) fixed on suitable size 6 M modular type G I switch board with top cover plate flushed in wall incl. mending good damages to original finish.
Supplying & fixing of 250 V 2 X 16 A modular type Switch, 2x16A 5 pin plug socket (make:Approve) fixed on suitable size 6 M modular type G I switch board with top cover plate flushed in wall incl. mending good damages to original finish.
Fittings & Fixtures and Earthing installation S & F Angular Holder with 9W LED lamp( make: Phillips/CG)
S & F of 36W 2ft X2 ft recess mountd celling LED light fittings white powed coated CRCA Housing with full window acrylic diffuser including necessary connection.(Make:CG / Philips/ Jaquar) (CAT NO.CCR-127-36-57-SL-NWH Aura 1/ RC380BLED30S 6500 G4 Full glow / LULTU15036XC Ultima Ultra)
S & F of Twin LED Fittings with 2x18W 2100 lm 1200 mm long PC body retrofit type tube light with box type metallic fittings as approved by P.W.D. (make: Phillips / CG)
S & F of Single LED Fittings with 1x18 W 2100 lm 1200mm long PC body retrofit type tube light with box type metallic fittings as approved by P.W.D. (make: Phillips /Crompton/)
Fixing only the tube light fittings directly on wall by means of HW block ball socket, ceiling plate , nipple / L Clamp , nipples with suitable fastner etc as required
S&F M/S fan clamp ( Average length of two piece suitable for holding MS steel structure above false ceiling as per EIC approved specification,fabrication from 40mm x 9mm MS flat, painting incl. mending good damages to the building.
S &F of 1200 mm sweep A C ceiling fans (make-C.G-zapar / Usha-striker).
S&F of 230V, 400W step type 2M electronic fan regulator suitable for existing modular switch board with top cover plate (make:-Approve)
S & F of metal body 450mm dia wall mounting fan. (make-C.G /Usha)
S & Fixing exhaust fan, Louver shutter after making hole in wall and mending good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of dia as follows (make: EPC Heavy duty)
(a) 9"exhaust Fan (920 RPM)
(b) 12"exhaust Fan (920 RPM)
© 16 "exhaust Fan( 920 RPM)
Supply and fixing compression type brass gland and fininshing the end of the cable by means of crimping method as to G S.
a) 4 core 50sqmm
b) 4 core 25 sqmm
c) 2 core 6 sqmm
S&F of required size solderless Cu socket of following Cu wires.
a) 6sq mm
b) 4sq mm
c)2.5Sqmm
d) 10 sqmm
Earthing the installation by 50 mm dia G I pipe by ISI-Medium on murrom soil.
Excavation of morrum soil
Supply and fixing Earth Bar 25 X 6 mm on wall incl suitable
Supply and fixing double door sheet steel (16SWG) power coated cable end box for TPN DB (Vertical/ Horizontal ) flushed in wall for smooth connection ow wires.
(a) 4 way horizontal PBDB
(b) 8 wat vertical PBDB
Supply and drawing 4 X 10 Sq mm PVC insulated Cu wire flexible from Terminal Box to PBDB incl both end socketing.
Supply and fixing of sheet metal Terminal Box with bakelite top cover plate flushed in wall with 1 No 63 A capacity 4 way bakelite base terminal block fixed in it for connection ow 25 sqmm 4 Core Cable to PBDB.
COMPOUND LIGHT Supply & Fixing of 2core 6 sqmm PVC /Al/Ar cable as per following manner from DP Main Switch to Security lightpoint incl. connection.(HAVELLS/POLYCAB/GLOSTAR/R R KABEL)
a) )Through wall at an average depth of 75mm with 1x10 SWG G.I wire
b) Through underground trench as to G S.
Supply & Fixing of 200mm x150mm x100mm GI loop box (door type) with G.I top cover having 4mm thick with rubber gasket terminal with lug etc comprising of one 250V kit-kat fuse unit,one NL on porcelain insulator etc incl. all connection.
S&L of 2x2.5sq mm + 1x1.5sq.mm FR single core multi strand copper wire (RRKable/Polycab/KEI) for loop in and loop out connection to fittings through 20 mm dia PVC Rigid pipe incl. connection.
S & F LED street light luminaire and all other accessories and necessary connection as per direction of EIC. (Crompton Cat No. LSTP 45 CDL/ Wipro LR13-501-XXX57-XX/JaquarLSRT015045XW)
S & F of 40mm dia 2.5 mtr long G I pipe ( ISI - M ) with suitable bend at one side as per design as pipe bracket (upto 1mtr) fixed on wall by means of 2 Nos clamping arrangement grouted in wall with 1 ft away from wall for easy distribution of light illimination and mending good the damages as per instruction of E I C. incl painting.
S/F 15 A Modular type switch with G I modular type switch board with top cover plate flushed in wall for controlling of security lighting system indiviually or in group manner.
S & F MF-1 starter on flat iron frame (make: L&T) on wall.
SHANKAR BHATTACHARJEE
M/S KALIMATA ENTERPRISE
RASH ELECTRICAL WORKS
M S CITY ELECTRICAL CO
SUBIR ENGINEERING WORKS (P) LTD
ELCON ENGINEERS
BRIGHT CONSTRUCTION
ROYAL ENGINEERS CO-OPERATIVE SOCIETY LTD
stage.html
html • 0.06 MB
techsummary_548373.pdf
PDF • 0.07 MB
finance_548373.pdf
PDF • 0.07 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_548373.pdf
PDF • 0.08 MB
NIQ7FIN.pdf
PDF • 0.61 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .