| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L2₹12.8 L+₹1.6 L (11.3%)Accepted-AOC GROUND FLOOR THAKUR COMPLEX BASANTPUR | BASANTPUR | SHIMLA | HIMACHAL PRADESH | 171018 | L2 | Accepted-AOC L1 | |
| 2 | L1₹14.6 LRejected-AOC LANE NO 5 HNO 560 SHAM VIHAR TALAB TILLO JAMMU | L1 | Rejected-AOC L2 | |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance | - | Not Admitted-Fee/PreQual/Technical/Finance Price Bid not complied | |
| 4 | Not Admitted-Fee/PreQual/Technical/Finance | - | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC | |
| 5 | Not Admitted-Fee/PreQual/Technical/Finance | - | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
Tender Value
Refer Docs
EMD Value
₹23,500
Closing Date
9 Jan 2021, 5:00 pmClosed
XEX Electrical division No. 1 Shimla-9
The Executive Engineer Electrical Division No-1 HPPWD Shimla-9
Providing Electrical installation at Isolation Ward First Second Floor in Old Ayurvedic Hospital Nahan Distt Sirmour HP
2020_PWD_43303_1
Electrical Div.No1PWD Shimla 2020-21-5325-28 dt.9-
Open Tender
Electrical Works
Item Rate
180 days
SHIMLA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
E.E.Electrical Division No-I Shimla-9
₹23,500
3 Jun 2021
17 Dec 2020
11 Jan 2021
17 Dec 2020
9 Jan 2021
17 Dec 2020
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required
Group-C
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps,modular switch, connections etc. as required.
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required
Supplying and fixing electrical switch board, having 3 No. of 5 amp. switches and socket on suitable size of metal box of mm deep 6 modules(205mmx78mmx50mm on surface or in recess with suitable size phenolic laminated sheet cover in the front i/c providing and fixing 3 No. 5 pin 5/6 amp socket outlet and 5/6 amp modular type switch, connection, painting etc.as req.(For light plugs)
Supplying and fixing 20 Amps, 240 volts, SPN industrial socket outlet, 2-pole & earth, metal enclosed plug top, sheet steel enclosure, suitable to accommodate a 20 Amp SPN-MCB/DP, on surface or in recess, with chained metal cover for the socket outlet, complete with connections, testing and commissioning etc. as required.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required
2x1.5 Sq. mm.
2x2.5 Sq. mm.
2x4 Sq. mm.
2x10 Sq. mm.
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core(flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulatedsingle core copper conductor cable for earthing as required.
Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required.
S.P. 5/ 6 Amps one way Modular switch
S.P. 15/ 16 Amps one way Modular switch
5 pin, 5/ 6 Amps Modular socket outlet
6 pin,15/16 Amps Modular socket outlet.
Supplying & fixing following size modular base and cover plate on the existing modular metal boxes as required:
Modular base and cover plate, 2 module
Modular base and cover plate, 4 module
Modular base and cover plate, 6 module
Modular base and cover plate, 8 module
Modular base and cover plate, 12 module
Supplying & fixing Modular blanking plate on the existing modular metal box as required
Supplying & fixing of G.I. modular boxes of following sizes along with modular base and cover plate for modular switches in recess as required:-
2 modules (78mmx78mmx50mm)
4 modules(140mmx78mmx50mm)
6 modules(205mmx78mmx50mm)
8 modules (120mmx135mmx60mm)
12 modules (205mmx135mmx60mm)
Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface /recessed, Steel/PVC conduit as required
3x1.5 Sq. mm.
3x4.0 Sq. mm.
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:- 25mm dia.
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-
Single pole. Cat-A.
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-
Double pole. Cat-A.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wireset, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-
Double door-12 way
Double door-8 way
Supplying and erection of light sub - panel (confirming to(IEC code-61439) of dimensions 700mm(H)*500mm(W)*300mm(D) with plus 5cm variation,made from 1.6mm thick M.S. Sheet duly fabricated in a segregated manner for housing of switch fuse units,by welding each compartment on five sides &front sides hinged,complete with locking arrangements to house 32 amp MCCB,63 amp Copper busbar & 1 set RYB light indicator and cable alley as required complete in all respects including the cost of switchgear . The cubical pedestal shall have cable entry box at one side,with epoxy powder coated approved paint and bonding to the existing earth etc.
Supplying and erection of light sub - panel (confirming to(IEC code-61439) of dimensions 700mm(H)*500mm(W)*300mm(D) with plus 5cm variation,made from 1.6mm thick M.S. Sheet duly fabricated in a segregated manner for housing of switch fuse units,by welding each compartment on five sides &front sides hinged,complete with locking arrangements to house 63 amp MCCB,63 amp Copper busbar & 1 set RYB light indicator and cable alley as required complete in all respects including the cost of switchgear . The cubical pedestal shall have cable entry box at one side,with epoxy powder coated approved paint and bonding to the existing earth etc.
Supplying and erection of light sub - panel (confirming to(IEC code-61439) of dimensions 700mm(H)*500mm(W)*300mm(D) with plus 5cm variation,made from 1.6mm thick M.S. Sheet duly fabricated in a segregated manner for housing of switch fuse units,by welding each compartment on five sides &front sides hinged,complete with locking arrangements to house 100 amp MCCB,100 amp Copper busbar & 1 set RYB light indicator and cable alley as required complete in all respects including the cost of switchgear . The cubical pedestal shall have cable entry box at one side,with epoxy powder coated approved paint and bonding to the existing earth etc.
Supplying and erection of sheet metal cubical pedestal (confirming to(IEC code-61439) of dimensions 1875mm(H)*2550mm(W)*450mm(D) with plus 5cmm variation,made from 1.6mm thick M.S. Sheet duly fabricated in a segregated manner for housing of switch fuse units,by welding each compartment on five sides &front sides hinged,complete with locking arrangements including 1 No. MCCB 500/630 amp(4 pole),1 No. MCCB 400 amp(4 pole),5 No. MCCB 100 amp(4 pole),2 No. MCCB 32 amp(4 pole),3 No. MCCB 63 amp(4 pole),1 No. MCCB 125 amp(4 pole),Changeover switch 160 amp(4 pole), copper busbar strips 800 amp,400 amp,125 amp,metering module & indicating lamp set.The cubical pedestal shall have cable entry box at one or two sides,with epoxy powder coated approved paint and bonding to the existing earth etc.The same shall be erected in the 1:2:4 cement concrete platform of suitable dimensions 15 cm high from ground level and 45 cm thick.The cubical pedestal shall be 15 cm from the top of cement concrete platform.
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-
Armoured cable 16 sq. mm (four core)
Armoured cable 35 sq. mm (3.5 core)
Armoured cable 240 sq. mm (3.5 core)
Armoured cable 400 sq. mm (3.5 core)
Earthing with copper earth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required.
Supplying and laying 8 SWG Copper wire at 0.50 mtr. Below ground level for earth electrode conductor, including soldering etc as required
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required
Ceiling Fan 1200 mm sweep, Category-A
Supplying and fixing stepped type Modular fan regulator on the existing modular box including making connections etc. as required.
Providing and installation of Light duty, plastic body, ventilating fan , light duty, (plastic body ) 250mm sweep in the existing opening, by means of suitable rag bolts/nuts ,including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- Make Havells, Bajaj, Crompton fan or any other approved by Engineer in charge
Providing and installation of following type of ultra slim decorative LED batten with extruded aluminium heat sink, with anti glare polycarbonate diffuser and energy efficient constant current, integral electronic driver; suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, including mounting clips & loop in loop out wire, connections, testing and commissioning etc. as required LED Batten Light 20W 1200mm Make: Philips, Syska, GE, Bajaj, C&S, Panasonic or any other approved by Engineer-in-Charge.
Providing and installation of following type of ultra slim decorative LED batten(Mirror light) with extruded aluminium heat sink, with anti glare polycarbonate diffuser and energy efficient constant current, integral electronic driver; suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, including mounting clips & loop in loop out wire, connections, testing and commissioning etc. as required LED Batten Light 10W 600mm Make: Philips, Bajaj, C&S or any other approved by Engineer-in-Charge.
P/F , energy saving,Step light in powder coated cast aluminium body with IP 54 protection LED luminaire comprising of high brightness LEDs complete with connections, testing & commisioning etc as required. LED 4 W
Supplying and fixing bakelite batten/angle holder including connections etc. as required:-
Providing and installation of following type of LED retrofit lamp B-22 holder base with polycarbonate body and aluminium heat sink; suitable for input voltage: AC 220-240 V, 50/60Hz, including mounting in existing fixture, testing etc. as required complete in all respects. LED retrofit lamp 7 W Make: Philips, Syska, GE, Bajaj, C&S, Panasonic or any other approved by Engineer-in-Charge.
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, providing and fixing of Nonreturn valve, Dead weight safety valve, 2 No C.P. connection rods 18" long, making good the damages, electrical connections, safety valve connections, testing and commissioning etc. as required:-
10 Liter capacity water heater (Cat-A)
25 Liter capacity water heater (Cat-B)
Supplying and fixing Ding-Dong / Electronic musical bell, suitable for D.C./A.C. single phase,230 volts complete as required:-
Note:-The credit for old dismantalled material will be recovered from the contractor on L/s basis @ Rs.5000/-Only.
Rakesh Kumar
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_64172.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .