| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.0 LAccepted-Finance | ₹47.0 L | L1 | Accepted-Finance Quoting Lowest rate |
| 2 | L2₹47.0 LRejected-Finance | ₹47.0 L | L2 | Rejected-Finance Quoting Higher rate |
| 3 | L3₹47.1 LRejected-Finance | ₹47.1 L | L3 | Rejected-Finance Quoting Higher rate |
| Sl No | Description | Qty | Unit | BISWANATH CHATTERJEE L1 | RIK ENTERPRISE L2 | SUBHASIS ROY L3 |
|---|---|---|---|---|---|---|
| 1.00SUB-HEAD 1--DISTRIBUTION WIRING Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) singlecore stranded 'HRFR' PVC insulated & unsheathed copper wire(Brand approved by EIC) partly in 20mm size PVC rigidconduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal &vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm)single core stranded 'HRFR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modulartype switch (Brand approved by EIC) fixed on Modular GI /PVC switch board complete with 2 no. suitable size “Ph & N”copper bar with top cover plate making earthing attachmentfixed on wall incl. mending good damages to original finish.[only PVC Rigid Conduit on ceiling and remaining portionconcealed] 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC | ||||||
| 1.01 | Average run 8 mtr [ 4(c) / E-25 ] | 40 | Pt | 1,480 ₹59,200 | 1,430 ₹57,200 | 1,380 ₹55,200 |
| 2.00Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'HRFR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI/ PVC switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC | ||||||
| 2.01 | On Board [ 3 (i) / E- 20 ] | 7 | Pt | 370 ₹2,590 | 365 ₹2,555 | 320 ₹2,240 |
| 3.00SUB-HEAD 2-- PLUGS, SOCKETS & WIRES Supplying & Fixing GI /PVC (As per direction of EIC) ModularSwitch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works | ||||||
| 3.01 | 4 Module | 30 | No | 325 ₹9,750 | 330 ₹9,900 | 300 ₹9,000 |
| 3.02 | 6Module | 50 | No | 410 ₹20,500 | 415 ₹20,750 | 350 ₹17,500 |
| 3.03 | 8 Module | 20 | No | 500 ₹10,000 | 502 ₹10,040 | 500 ₹10,000 |
| 3.04 | 12 Module | 12 | No | 650 ₹7,800 | 656 ₹7,872 | 656 ₹7,872 |
| 3.05 | 2 Row 12 Module | 15 | No | 780 ₹11,700 | 788 ₹11,820 | 788 ₹11,820 |
Tender Value
Refer Docs
EMD Value
₹94,000
Closing Date
10 Feb 2026, 11:00 amClosed
Office of the Sr. Superintending Engineer, Western
Office of the Sr. Superintending Engineer, Western Electrical Circle , PWD, Purta Bhavan, 1st floor, Burdwan-713103
Repairing and Renovation work of indoor and outdoor building incl. labor room and OT room at Labpur R.H ,Labpur, Birbhum,PWD...allied E.I Work.
2026_WBPWD_992639_1
WBPWD/SSEWEC /BRED /NIQ-74 /2025-26
Open Tender
ELECTRICAL WORKS ORG
30 days
Labpur
Please refer Tender documents.
5 documents required · 5 mandatory
₹94,000
Office of the Sr. Superintending Engineer, Western
15 May 2026
21 Jan 2026
12 Feb 2026
21 Jan 2026
10 Feb 2026
3 Feb 2026
21 Jan 2026 - 2 Feb 2026
2 Feb 2026
SUB-HEAD 1--DISTRIBUTION WIRING Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) singlecore stranded 'HRFR' PVC insulated & unsheathed copper wire(Brand approved by EIC) partly in 20mm size PVC rigidconduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal &vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm)single core stranded 'HRFR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modulartype switch (Brand approved by EIC) fixed on Modular GI /PVC switch board complete with 2 no. suitable size “Ph & N”copper bar with top cover plate making earthing attachmentfixed on wall incl. mending good damages to original finish.[only PVC Rigid Conduit on ceiling and remaining portionconcealed] 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC
Average run 8 mtr [ 4(c) / E-25 ]
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'HRFR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI/ PVC switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC
On Board [ 3 (i) / E- 20 ]
SUB-HEAD 2-- PLUGS, SOCKETS & WIRES Supplying & Fixing GI /PVC (As per direction of EIC) ModularSwitch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works
4 Module
6Module
8 Module
12 Module
2 Row 12 Module
3 Row 18 Module
Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI/PVC (As per direction of EIC)Modular type switch board having top cover plate and making necessary connections as required
Supply & Fixing 240 V 16 A Piano key type switch (Brand approved by EIC) on GI/PVC Modular type switch board having top cover plate and making necessary connections as required
Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI /PVC(As per direction of EIC) Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI/PVC(As per direction of EIC) Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plugsocket (Brand approved by EIC), without plug top and switch, on existing GI/PVC(As per direction of EIC) Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI/PVC(As per direction of EIC) Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
S&F16A Modular switch type DPMCB (C-Curve) and Indicator
Supplying & Fixing GI /PVC (As per direction of EIC)Modular Switch Board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works(E-17/F-2)
2 module
4 Module
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [5(a)/E-17] [AC socket ]
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [17/E-19 ] [AC starter]
Cutting channel of 31 mm x 31 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire fish wire incl. mending good damages to building works
13 mm dia 3 mm thick polythene pipe without earth continuity wire. [ 2(a)/ E- 2 ]
Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works
19 mm dia 3 mm thick polythene pipe without earth continuity wire [ 3 (a)/ E- 2 ]
Supplying and fixing PVC Rigid Conduit MMS 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works
20mm size
25 mm size
Supplying and fixing GI flexible conduit with pvc coating [Make-As per choice of EIC] from individual loop box to arm bracket.16mm size
Supplying and Drawing 1.1 KV single core stranded 'HRFR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS. Make : Polycab/RR/Gloster
3 x 22/0.3 (1.5 sqmm) [1(b) / E- 9 ] [For Separate plug & distribution point beyond specified run]
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC [ 1(s) / E-9 ] [ For PP & Multiple Plug Board]
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC [ 1(v) / E- 9 ] [For multiple PP & AC]
2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC [ 1(y) / E- 9 ] [For TPNDB to SPNDB]
4x36/0.3 (2.5 sqmm) + 2x22/0.3 (1.5 sqmm) as ECC[E-9,1u] For 3-Phase Concealed AC
4x56/0.3 (4 sqmm) + 2x36/0.3 (2.5 sqmm) as ECC[For 3 Phase Autoclave]
4x84/0.3 (6 sqmm) + 2x56/0.3 (4 sqmm) as ECC [ 1(a1) / E- 9 ] [For UPS ]
4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC [ 1(g1) /E- 9 ] [ From VTPN to TPNDB]
2 x 80/0.4 (10 sqmm) ( for Earthing) [ 1(m) /E- 9 ]
2 x 84/0.3 (6 sqmm) [ 1(j) / E- 9 ]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
1.5 sqmm [N.S.]
2.5sqmm [9 (i)/F-5]
4 sqmm [9 (ii)/F-5]
6 sqmm [9 (iii)/F-5]
10sqmm [9 (iv)/F-5]
16sqmm [9 (v)/F-5]
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall as per GS
Supply & Fixing bakelite / perspex top cover on existing Inspection board by Brass screws
SUB-HEAD 3--BDB,PDB,VTPNDB Supplying and fixing 415V, 63A TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc [HPL MAKE/Standard/Havells] [ for UPS Output bypass]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
2+10 Way[ Legrand /ABB/Seimens] [ 13 / D- 9 ]
2+14 Way[ Legrand /ABB/Seimens ] [ 13 / D- 9 ]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
6 way [Legrand /ABB/Seimens] [ 14 / D- 10 ]
4 way [Legrand/ABB/Seimens] [ 14 / D- 10 ]
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending goodthe damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
8 Way Enclosure (upto 160A) [15/D-11]
12 Way Enclosure (upto 160A) [15/D-11][For First Floor]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand /ABB/Seimens ]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand/ABB/Seimens ]
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 35kA in existing Vertical DBs including necessary connection as per GS incl.S&F suitable size of spreader link [ Make - Legrand/ABB/Seimens ].
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for 12way / 8way TPN DB vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment. [16/D-12]
8 Way VTPN [16/D-12]
12 Way VTPN [16/D-12]
6 /4Way HTPN [16/D-12]
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. 4 Way [ 11/D-9]
Supplying and fixing 415 V 125A Four Pole MCCB of Breaking capacity 35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting & both side spreader link with suitable size enclosure fixed on wall by flat iron frame and necessary connection incl.S&F suitable size of spreader link. (For X-Ray machine)
SUB-HEAD 4-- SUPPLY & LAYING OF CABLES Supply of 4/2 Core XLPE Insulated & Sheathed armoured Copper/Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make- Havells/Polycab/RR]
2 Core 16 Sq. mm [ NS ] [for compound light]
4core 35Sqmm [ NS ] [For feeding emergency power from existing DG]
4Core 70 Sq. mm Aluminium Conductor [ NS ] [ From Panel to X-Ray unit]
4Core 95 Sq. mm Aluminium Conductor [ NS ] [ From Panel to 125A I/C of VTPNDB ]
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting [ 2(b) /F1] [for 2core16Sqmm]
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core
Laying of one No. cable upto 35 sqmm in underground trench 460mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/ surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting. [ 2(c) /F1] [ for 4core 35Sqmm][For imergency power feeding from 25KVA DG]
Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting. [ 2(d) /F1] [ for 4core 70Sqmm]
Laying of cable above 3½ core 90 sqmm and upto 3½ core 150 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting[ 2(e) /F1]
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. With 25x25x3mm angle iron support. [34.(a)/D-14]
200x50x1.25mm (18SWG)
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
2 Core 16 Sq. mm [7(a)/F4 ]
4core 35Sqmm [7(c)/F4 ]
4core 70Sqmm [7(c)/F4 ]
4core 95Sqmm [7(c)/F4 ]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.
2 Core 16 Sq mm [ 8(b) /F5]
4core 35Sqmm [ 8(b) /F5]
4core 70Sqmm [ 8(b) /F5]
4core 95Sqmm [ 8(b) /F5]
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings as per GS
32 mm dia [11(d)/F-6]
50 mm dia [11(d)/F-6]
SUB-HEAD 5 -- FIXING OF FANS Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991) [ 29/D-14 ]
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. [10/E-18]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS [ 21 (a) / C-3 ]
Fixing only exhaust fan after making holes in wall as per GS.
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long)
SUB-HEAD 6 -- SUPPLY OF FANS Supply and delivery of 230V 1200mm sweep ceiling fan (32Watt or less BLDC fan, class of insulation -'B', SERVICE VALUE (CMM/W minimum 6.85, R.P.M. 350(min), THD <10%, supplied with out remote control P.F. not less than 0.9, bult-in 2.5KV SPD with complete accessories. [Make: Crompton /Orients/ Usha (With 2 years Warrenty)]
Supply and delivery of 230V 900mm sweep ceiling fan (32Watt or less BLDC fan, class of insulation -'B', SERVICE VALUE (CMM/W minimum 6.85, R.P.M. 350(min), THD <10%, supplied with out remote control P.F. not less than 0.9, bult-in 2.5KV SPD with complete accessories. [Make: Crompton /Orients/ Usha (With 2 years Warrenty)
Supply of Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC/Crompton/Usha As per choice of EIC ) [ NS ]9"( 230mm ) Speed 1370 RPM
Supply of Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC/Crompton/Usha As per choice of EIC ) [ NS ]12"( 300mm ) Speed 920 RPM
Supply of 240V 85Watt Full Metal body wall bracket fans (450 mm Sweep) complete with all accessories. ( Make -EPC /Crompton/Usha As per choice of EIC)
SUB-HEAD 7 -FIXING OF LIGHT FITTINGS Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling as per GS. [14(d)/C-2]
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [ 17/C-2 ]
Fixing only outdoor / street light type LED light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages towall and painting [19/C-3]
S& erection of 80mm dia, 1.5 mtr long G.I. pipe (ISI-M) with base plate in CC foundation with approved paint including providing muffing 0.45x0.45x0.3mtrs above roof level with neat cement finish.
S/F 200mmx250mmx100mm SMC loop box with hinged type single door fixed on pole above 1.5mt from RL by welding two number 40mm X6mm MS flat on Steel tubular pole & the loop box fixed with this flat by four number suitable size nut bolts. And also S&F of 4 way terminal block & One number 6A SPMCB for easy connection of existing out going cables to compound light with necessary inter connection as per direction of E.I.C. (Make-Sintex)
Supply & Fixing single arm bracket of 1500mm long made by 40mm dia MS pipe incl. 100mm sleeve, CI pole cap, Through bolt etc & painting.
S&F Street light/Outdoor light/Compound Light Timer (Water Proof) in wall incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment and febricated with following items as per instructions of EIC i) 250mm x250mm x100mm water proof SMC encloser ---- 1No(Sintex make) ii) 240 V, 6-32 A SPMCB of breaking capacity 10KA & ''C'' Charecteristic -- 01 no(Legrand) iii) 240V , 2P, Power Contractor with accessories ----- 01 no(L&T MNX-22) iv) Astronomical time switch --- 01no(Astro Mini Cat no.T2DDT7) v) Toggle switch for manual/auto operation --- 01no. vi) 63A 2 pole terminal studs & neutral links- 1 no. vii) Necessary connection by copper wire.
S/F 200mmx250mmx100mm SMC loop box with hinged type single door fixed on wall by welding two number 40mm X6mm MS flat on wall & the loop box fixed with this flat by four number suitable size nut bolts./ on wall by four number fastner. And also S&F of 2 way terminal block & one number 6A SPMCB for easy connection of existing out going cables to compound light with necessary inter connection as per direction of E.I.C. (Make-Sintex)
SUB-HEAD 8 - SUPPLY OF LIGHT FITTINGS Supply of 4 Ft. 20 Watt single/twin LED light fitting for indoor application,complete with all accessories & Lamps having following Model Make Philips Cat No MASLEDTUBE1200mm 18W865T81-2100lm/Jaquar Cat No BTI-WHT-LTBL01X020WC/Surya Cat No SLETLDS20PCREFORM(NANO) ). .( 3 years Warrenty)
Single LED fittings (Make: Philips Cat No Tmc 5021XT-LED 22WJaquar Cat No ACI-WHT-LBOX-FTG020XX/Surya Cat No SUB118T8LED ) ( 3 years Warrenty)) with 1no. Master LED tube with metal heatsink 1200mm 14W865 T8 I – 2100lm (PC body)
Double LED fittings (Make: Philips Cat No Tmc 502PXTLED22W/Jaquar cat No. ACIWHT-LBOXFTG040XX/Surya Cat No Surya Cat No SUB218T8LED ) ( 3 years Warrenty)) with 2nos Master LED tube with metal heatsink 1200mm 14W865 T8 I – 2100lm (PC body)
Supply & Fixing Master LED tube with metal heatsink 1200mm 14W865 T8 I – 2100lm (PC body) [ For replacement of existing Flourescent tube]Make : Philips/Surya/Jaquar (With 3 years Warrenty)
Supply & Fixing of 12W LED lamp of 110 lm/watt, to the lamp point.Make : Philips/Surya/Jaquar
Supply&fixing of water proof LED Bulk Head fittings ( Make : Philips/Surya/Jaquar (With 5 years Warrenty) having similar specification ) . [N/S]
Supply and delivery of LED Street Light(230vac, 60 W, 130 Lumen/Watt, 6500K, IP 66, THD<10%, bult in ,CRI>80%, ) with all necessary connection.[Make : Philips/Surya/Jaquar (With 5 years Warrenty) similar specification of Crompton/ Havells/ Bajaj].
Supply and delivery of LED Street Light(230vac, 120 W, 130 Lumen/Watt, 6500K, IP 66, THD<10%, bult in ,CRI>80%, ) with all necessary connection.[Make: PHILIPS /Suriya/Jaquar similar specification (With 5 years Warrenty)
SUB-HEAD 9 - SITC of LT Panel SITC of floor mounted Indoor type cubical MV switchboard, fabricated by CPRI approved panel maker having compartmentalized design, fabricated out of 14 SWG ( 2.0 mm ) nominal thickness CRCA sheet steel for framework and covers, and 3 mm nominal thickness for gland plates, including cleaning and finishing complete with 7 tank process, with short circuit withstand capacity of 31 MVA for one second, front openable, hinged, single shuttered, single door, with locking arrangement, good quality dust, damp and vermin proof rubber gaskets, solid connections from main busbars to switchgears & Switchgear to cable alley with required size of copper busbars, and control wiring using 2.5 sq. mm of RYB colour coded FRLS PVC Insulated Copper conductor single core cables and copper cable lugs
1 no. of 50 mm x 6 mm GI earth strip for earthing, both side cable alleys, cable gland plates in two halves, dinrail for mounting switchgear, metering arrangements, drilling holes, detachable gland plates/knockout plates, providing 50 mm x 50 mm x 5 mm nominal thickness MS angle iron support for MCBs alongwith horizontal/vertical intermediate MS flat members for stiffening, mounting on MS channel iron framework 100 mm x 50 mm x 5 mm (9.2 kg/metre) for floor mounting of MV panel, providing MS plate, suitable for bottom/ top cable entry, grouting in ground, powder coating, providing and fixing the following switchgear and measuring instruments, earthing, cartage from fabricator's premises to site of work etc. as required.[ MCCBs will be ABB / Legrand/ Siemens/ Schneider Make. All the other accessories will be Legrand/Siemens/L&T Make and as per manufacurers standard ].
BUSBAR S&F 99.9% - 99.5% electrolytic tinned copper (Type test Certificate should be produced by manufacturer) semi soft, tined electroplated with heat srinkable PVC sleeve 4 Bar Bus Bar of Proper Size mounted on non-hygroscopic porcelain insulator/hylam sheet having sufficient di-electric strength duly wrapped with colour PVC sleeves (Red, yellow, blue & black) for phases & neutral identification & all connection made with required size cu bars (considering current density1.6A/Sqmm). i) 400A -1 Set
INCOMER Supply & fixing of 250A and 415V, 4 pole 50 kA (Uimp=8KV), Ics= 100% Icu MCCB with microprocessor based release (LSIG) having adjustable O/L (0.4 to 1x In or better), Adjustable S/C (1/1.5 - 8/10 Ir), Inbuilt Instantaneous protection, Adjustable E/F , and, There should be indication for trip cause, Both side spreader link, extended rotary handle. There should be LED indicating lamp for showing On, OFF, TRIP & R,Y,B, indication on the panel door etc. - 2Sets [ There should be castle key interlocking arrangement for both the Incomers]
OUTGOING Supply & fixing of 125A and 415V, 4 pole 36 kA MCCB with thermal magnetic release Both side spreader link, extended rotary handle. etc. - 6Set
Supply & fixing of 32A and 415V, 4 pole 36 kA MCCB with thermal magnetic release Both side spreader link, extended rotary handle. etc. - 2 Set
METERING Supply & Fixing 3 phase 415V Multifunction Meter of 0.5S accuray, capable of display 3 phase parameters at a time with LED disply & folowing parameters can be measured V, A, F, kW, KVA, kVAr, kWh, kVAh, kVArh, PF, Phase angle, THD, Events, Neutral current, Max Demand (with RTC)
Supply & Fixing of following : 200/5/1 CT - 3 nos. 6 A TPMCB - 1 no. 6 A SPMCB - 1 no.
SUB-HEAD 10 - Miscelleneous Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) as per GS [ 20( a )/D-13 ]
Supplying & Fixing of PVC water proof type Loop box (Make-Sintex GSJB2520 /Hensel) of size [250X200X100]mm having hinged PVC top cover & 4 mm thick with rubber gasket lining,railway type mechanical locking arrangement, with DIN rail. on wall as per direction of EIC.
S&F of 615V, 32A, 4 Pole copper connector with necessary connection.
S.I.T.C. of Crono time switch [Make - L&T Cat. No. 67DDT0]
S & F of 4 pole 25A DIN rail mounted Power contactor with 240V operating coil [ make L&T/ ABB/ Siemens/ Schneider].
S&F of 250V, 25A timer controlled single starter for room Air Conditioning machine in SS double door 14-way DB enclosure ( Legrand make) with S&F following electrical accessories & front door locking arrangement with all connections by finishing the ends of 2 x 4 & 1 x 2.5 mm² copper wire with dowells solderless socket by crimping method as to GS, earthing attachment on wall icl necessary connections as per direction of EIC:-
i) 25A DP MCB (L&T/ ABB/ Legrand make) -- 1no
ii) 24Hr x 7days programmable Digital timer (L&T make Cat no 67DDT0) -- 1no
iii) 3-pole power contactor (L&T make cat no MNX22/250V) -- 1 no.
iv) 2-Modular AC motor starter (Legrand/Myrius Cat no 673031) -- 1 no.
v) 1-module 10A Modular switch (Make Legrand /Myrius) -- 1 no
vi) 3-module plate with cover (Make Legrand /Myrius) -- 1no
vii) 25A Auto-Off-Bipass SPDT toggle switch (appvd reputed make) - 1 no.
viii) LED indication lamp (approved reputed make) -- 1 No.
ix) Outgoing bakelite connector 32A (Reputed make as approved by EIC) - 4 nos.
Supply of Single LED fittings (Make: Philips Cat No Tmc 5021XT-LED 22WJaquar Cat No ACI-WHT-LBOX-FTG020XX/Surya Cat No SUB118T8LED ) ( 3 years Warrenty)
Supply of Double LED fittings (Make: Philips Cat No Tmc 502PXTLED22W/Jaquar cat No. ACIWHT-LBOXFTG040XX/Surya Cat No SUB218T8LED) ( 3 years Warrenty)
SUB-HEAD 11 - SITC of UPS SITC of 10KVA True Online Double Conversion IGBT based UPS system with Advanced DSP based Technology and having minimum output power factor 0.9 with 415V Three phase input & 240V Single phase output, minimum Efficiency 90% and following minimum accessories. a) Inbuilt / Separate isolation Transformer with cabinet b) The UPS must have inbuilt memory to store & disply event log, fault history, load percentage, battery condition etc. c) Suitable size Battery rack, d) Total minimum VAH 20160 SMF battery FR grade for each UPS to provide 30mins. Battery backup at Full load. Make : Amararaja Quanta / Exide Power Safe plus [ APC/ Delta/ Vertiv/ Numeric ]
SUB-HEAD 12 -SITC of LED sign Board Supply, installation, testing and commissioning of LED illuminated sign board made of 1” x1” Iron hollow square bar with sufficient support bar in between the structure and fitted in wall with L channel and angle iron at the front side of the building. Thickness of the board in four sides are 150mm. Back side of the board should be covered 24swg aluminum sheet to resist unwanted water seepage. 3 mm thick ACP sheet fixed at front & four sides with corners are finished by router cutting.The encrypted matter will be printed in front of ACP sheet by laser cutting and the letters of same matters are made by 3mm thick good quality milky white acrylic sheet & pasted in front of laser cuts of ACP sheet. The boards should be fixed on wall by necessary MS angel/ flats. There will be provision for easy opening of the bord during maintenance work. The cost including scaffolding charges(for 2 storied building) and painting with 2 coat of RO primer and one coat of synthetic enamel paint.
Supplying & fixing 18W,2100 lumen Master LED tube with metal heat sink (Philips) with necessary holder for connection incl necessary tie bar arrangement to hold the tubes horizontally.
SUB-HEAD 13- Earthing Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F suitable heavy type heat shrinkable PVC sleeve to cover 50 mm x 6 mm GI flat, to an average depth of 3.65 Mts. [ 2nos for main panel, 2nos for UPS neutral ]
S&F 50 mm x 6 mm galvanized (Hot Dip) steel strip beyond 4 Mts for each earthing. [5.e/G-3]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe. [3.a/G-2]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required[G-2/4-C]
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.[G-3/5(d)]
SUB-HEAD -14 SITC of FDA System Supply, Installation, Testing & Commissioning of Analog Addressable Intelligent multi sensor detector (VDS / UL / FM / ULC approved) with inbuilt optical smoke sensors as well as additional heat detector sensor with decentralise intelligence, soft addressable Photo thermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per recommended standard.(Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards) without any additional cost). (Approved Make: Siemens/Esser/ Cerberus Pro/ Bosch/ Johnson Controls/ Notifer / Edward/ Secutron/ Securiton/ GST
Supplying, installation, testing and commissioning of Addressable Heat Detector (Fixed temperature cum rate of rise) ( VDS / UL / FM / ULC approved ) with twist lockable removal base, built - in fault isolator, drift compensation feature etc including connections as per specifications complete as reqd and having IP as per recommended standard(Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost). (Approved Make: Siemens/Esser/ Cerberus Pro/ Bosch/ Johnson Controls/ Notifer / Edward/ Secutron/ Securiton/ GST
Supplying, installation, testing and commissioning of LED type Response Indicator (VDS / UL / FM / ULC approved) having 2 Nos. red coloured LED lamps including connections etc. (Approved Make: Siemens/Esser/ Cerberus Pro/ Bosch/ Johnson Controls/ Notifer / Edward/ Secutron/ Securiton/ GST
Supply, Installation, Testing & Commissioning of Addressable Manual Call Point (VDS / UL / FM / ULC approved) soft addressable type within built fault isolator as per NFPA style 7 wiring complete as required. (Approved Make: Siemens/Esser/ Cerberus Pro/ Bosch/ Johnson Controls/ Notifer / Edward/ Secutron/ Securiton/ GST
Supply & Laying of 2 Core 1.5 sq.mm FRLS screen shielded copper Cable (Make. Finolex / Havells / Polycab) in prelaid PVC rigid conduit pipe.
Supply & Drawing 20 mm NB PVC rigid conduit pipe (Make: Precision) on wall incl necy. Bend, elbow etc.
Supply, Installation, Testing & Commissioning of Microprocessor based Intelligent, addressable expandable and fully networkable fire alarm control panel ( VDS / UL /ERTL / LPCB / FM approved ) suitable for the devices as stated in the previous items of this BOQ along with 20% spare capacity with each loop loading not exceeding 80% of the full capacity of detectors and devices taken together, complying to IS 2189:2008 or its latest amendments, and with minimum 600 character alpha - numeric liquid crystal display. The panel shall be soft addressable type and shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches whenever any alarm is triggered. The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards.
The panel shall have in built rectifier, provision for external & internal printer (if required ), Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 30 minutes during Emergency condition, with integral battery charger complete in all respect as required.
The FACP shall be capable of being networked (future expansion) with other similar FACP located at different part of the premises through single RS 485 bus. The FACP shall have provision for interfacing with the public address system, remote computer and BMS interface. The system must be preloaded with licensed software. (Approved Make: Siemens/Esser/ Cerberus Pro/ Bosch/ Johnson Controls/ Notifer / Edward/ Secutron/ Securiton/ Apollo/ Morley/ Eaton).
Sub-Head-15 SITC of Concealed Split AC(Three phase&Single phase) S&D of minimum 13KW nominal cooling capacity ceiling suspended [ concealed] Split Air Conditioner with R410A / R407C / R-32 Refrigerant, with single Scroll Compressor / Swing compressor in inverter machine, suitable for operation on 415V,+_ 5% , 50Hz, 3Ph AC Supply. with precharged refrigerant, Wired/ Wireless remote & all other accessories (Make : DAIKIN model FDMF140BRV16/ RZMF140BRV16 / Mitsubishi heavy industries model FDUM125CSV-S6/FDC125CSV-S6 / O General model ARG60F/AOG60F). As per choice of EIC
Installation testing & commissioning of above AC machines by fixing the indoor with two number 1.5mt long MS equal angle of sizes 50mmX50mmX 6mm to fixed by 250mm grouting on wall with 2nos strut of suitable length. The indoor unit suspended from this angle support with 4 nos 10mm full threaded suspender bolt with double nut & spring washer. Out door unit will be fixed on roof with iron chair of size 900mmX 300mm of height 300mm made by 50mmX50mmX6mm MS angel incl painting by two coat of synthetic enamel paint over one coat of RO primer, as per direction of EIC.
S&D of minimum 7KW nominal cooling capacity ceiling suspended [Concealed] medium static, Split Air Conditioner with R410A / R407C / R-32 Refrigerant having single Rotary Compressor / Swing compressor for inverter machine, suitable for operation on 240V,+_ 5% , 50Hz, 1Ph AC Supply. with precharged refrigerant, Wired/ Wireless remote, filter & all other accessories (Make : Mitsubishi heavy industries model FDUM71CNV-S6 / O General model ARG25FUAN + AOG25FNANL DAIKIN model FBQ71DV1+RZQ71KCV4A). As per choice of EIC
Installation testing & commissioning of above AC machines grouted into the wall by fixing the indoor with two number 1 mt long MS equal angle of sizes 40mmX40mmX 6mm to fixed by welding in both end to the existing joist on wall. The indoor unit suspended from this angle support with 4 nos 10mm full threaded suspender bolt with double nut & spring washer. Out door unit will be fixed on wall with two number 1.2mt long MS "C" channel of sizes 80mmX40mmX 6mm by one side grouted into the wall as per direction of EIC.(MS Anglel must be painted by 1 coat of RO primer and 2 Coat of enamel paint)
Supply & laying drain Water piping work with 25 mm dia Schedule 40 PVC/ UPVC hard pipes (Finolex / Ashirbad / Supreme) incl. fitting , accessories bends, elbows, tees, flanges, tapings, etc. insulated with 9mm. thick nitrile rubber tube insulation.
S&F flexible canvas connection for indoor to duct/ air terminal for
13KW indoor
7KW Indoor
SITC of Powder Coated Al. Grill without VCD suitable size (Make:Systemair / Primier)
S & providing drop ceiling to cover the indoor units & supply air duct including the cost of 3mm thick ACP sheet as per manufacturer's specification on the frame work fabricated from Aluminium hollow rectangular section of size 50mm x 25mm (1.6mm thick) & duly suspended by Aluminium hollow rectangular section of size 50mm x 38mm (1.6 mm thick) and silicon sealent complete in all respect including making trap door arrangement as per direction of EIC. (Make:Aludecor/Pratapbond)
Copper pipe 9.5mm dia, min. thickness 0.8mm (Make : Rajco / Mandev) with 9mm thick nitrile insulation.( Accoflex/K-flex/Armasell)
Copper pipe 19.05mm dia, min. thickness 0.99mm(Make :Rajco / Mandev) with 9mm thick nitrile insulation. (Accoflex/K-flex/Armasell)
Supply & Laying of PVC insulated unarmoured 1.1 KV grade 6 Core 2.5sq mm copper cable from indoor to outdoor unit with necessary fixing arrangement. (Finolex / Polycab / Havells)
Supply & Laying of Refrigerant Copper pipe of following diameter for connecting of Indoor to Outdoor unit, along with drip resistant nitrile rubber insulation with double insulating wrapping tape to avoid dripping of condensate water:-
Discharge Line 6.35mm dia, min. thickness 0.8m with 9mm thick nitrile insulation. (Make : Rajco / Mandev / KFlex.
Suction Line 15.88mm dia, min. thickness 0.99mm with 9mm thick nitrile insulation. (Make : Rajco / Royku/KFlex.
Supply & Laying of PVC insulated unarmoured 1.1 KV grade 4 Core 2.5sq mm copper cable from indoor to outdoor unit with necessary fixing arrangement. (Finolex / Polycab / Havells)
Wrapping the copper pipe with insulation & electric cable by S/F 28 SWG Aluminimum sheet to make it weather & vermin proff.
6mm dia with 9mm thick nitrile insulation, 15.9mm dia with 9mm thick nitrile insulation & 4core 2.5Sqmm Copper cable.
9.5mm dia with 9mm thick nitrile insulation, 19.05mm dia with 9mm thick nitrile insulation & 6core 2.5Sqmm Copper cable.
Dismantling of the existing split type AC machine (1.5/2.0 Ton) along with the outer cover carefully by skilled labour from its position for necy. Servicing /overhauling incl cleaning the dust ete. due to dismantling operation and also uninstalled & removing of unused old damaged windows AC unit from wall and covered the vacant space by ACP board with necessary dimension with good mending and damages as per direction of EIC as per direction of E.I.C.
Charges for dismantling & mending good the damages of existing LT panel, Fuse type HTPN, SPN DB, Iron clad isolator & cable leads, damage Switch boards, Socket boards etc.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 17.49 MB
BOQ_2427418.xls
BOQ • 0.43 MB
new2911.pdf
Tender Documents • 0.51 MB
Download all tender documents and submit your bid