Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.6 LAccepted-AOC 704 SILVER DEAL DAFFODIL WING 1 B T KAWADE ROAD PUNE 411 001 | PUNE | PUNE | MAHARASHTRA | 411001 | L1 | Accepted-AOC Lowest bid value | |
| 2 | L2₹35.8 L+₹62,168 (1.77%)Rejected-AOC | L2 | Rejected-AOC Higher bid value | |
| 3 | L3₹37.6 L+₹2.3 L (6.67%)Rejected-AOC | L3 | Rejected-AOC Higher bid value | |
| 4 | L4₹38.9 L+₹3.7 L (10.5%)Rejected-AOC | L4 | Rejected-AOC Higher bid value | |
| 5 | L5₹40.8 L+₹5.6 L (15.9%)Rejected-AOC | L5 | Rejected-AOC Higher bid value |
Tender Value
Refer Docs
EMD Value
₹82,000
Closing Date
3 Jun 2023, 6:00 pmClosed
GE (AF) BANGALORE
GE (AF) BANGALORE, HQ TC AIR FORCE , BANGALORE 560006
REPAIR/MAINTENANCE TO LT PANEL LT CABLES MCCBs AND CONNECTED WORKS POCKET I AND II AT CHAF BANGALORE
2023_MES_593134_1
8105/GE/30
Open Tender
Civil Works
Item Rate
270 days
GE (AF) BANGALORE
AS PER NIT
6 documents required · 6 mandatory
₹500
GE (AF) BANGALORE
₹82,000
21 Jul 2023
4 May 2023
9 Jun 2023
4 May 2023
3 Jun 2023
19 May 2023
5 May 2023 - 11 May 2023
Amount
M & L in repair of Straight through joints heat shrink type suitable for 10 to 16 Sq. mm. x 3.5/4 core sizes of PVC/XLPE insulated and PVC sheathed armoured LT underground cable with aluminium conductors including joint kits and labour complete for making joints all as specified and as directed. Make : Raychems/M-Seal/Birla-3M/Yamuna Densens.
All as per Item No 1. here in above but for 25 to 50 Sq. mm. x 3.5/4 core
All as per Item No 1. here in above but for 70 to 150 Sq. mm. x 3.5/4 core
All as per Item No 1. here in above but for 240 to 300 Sq. mm. x 3.5/4 core
Excavation in trenches not exc. 1.5m wide and not exc 1.5m in depth and getting out in soft /Loose soil for laying of cable all as specified and directed and as directed.
Returning filling in, including spreading, levelling, watering and well ramming in layer not exc 25cm all as specified and as directed.
Removal of surplus soil (excavated soil) to a distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point all as specified and as directed.
M & L River sand, spread dry in trenches as in cable cushioning all as specified and as directed.
Supply and laying un-reinforced precast concrete cable cover Class LV, Type I, flat, size 250 mm x 150mm x 40mm laid in trenches as in protection of UG cables all as specified and as directed.
Taking up or down unserviceable steel tubing and connections of sizes 50/80 mm etc complete all as specified and directed.
Supply and Fix GI tubing light grade 50 mm bore as in cable protection fixed to poles/walls or laid intrenches/under road crossing etc all as specified and as directed.
All As per Item No 11 here in above but for 80 mm bore
Taking down old unserviceable UG cable of any size etc complete all as specified and directed.
M & L for LT UG cable 4 core x 16 sq mm 1100 Volts grade XLPE insulated , flat steel armored, heavy duty with aluminium conductor laid in trenches or fixed to walls/ poles or passing through pipes with and including,cable gland lugs/ thimbles/ ferrules including connecting, testing and commissioning complete for the following sizes including taking down existing LT UG cable of any size at site all as specified and as directed. Make : Havells/Polycab/Universal Notes: (a) Excavation earth work and sand cushioning brick protection and connected work etc. Shall be measured and paid separately under relevant item of schedule (b) Rate quoted deemed to include for cutting and removing of defective joints where required as directed.
All as per Item No 14. here in above but for 3.5 core x 25 Sqmm
All as per Item No 14. here in above but for 3.5 core x 35 Sqmm
All as per Item No 14. here in above but for 3.5 core x 50 Sqmm
All as per Item No 14. here in above but for 3.5 core x 70 Sqmm
All as per Item No 14. here in above but for 3.5 core x 95 Sqmm
All as per Item No 14. here in above but for 3.5 core x 120 Sqmm
All as per Item No 14. here in above but for 3.5 core x 240 Sqmm
Supply and laying in repair of 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape unarmoured and overall PVC sheathed 10 sq.mm , 2 core nominal cross section in service connections etc complete all as specified and directed. Make : Havells/Polycab/Universal
Supply and laying in repair of 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq.mm 4 core nominal cross section in service connections etc complete all as specified and directed. Make : Havells/Polycab/Universal
S & F in repair Al cable lugs of size 16 Sqmm as specified
S & F in repair Al cable lugs of size 25 Sqmm specified
S & F in repair Al cable lugs of size 35 Sqmm as specified
S & F in repair Al cable lugs of size 50 Sqmm as specified
S & F in repair Al cable lugs of size 70 Sqmm as specified
S & F in repair Al cable lugs of size 95 Sqmm as specified
S & F in repair Al cable lugs of size 120 Sqmm as specified
S & F in repair Al cable lugs of size 240 Sqmm as specified
S & F in repair Al IN-Line connectors of size 16 Sqmm as specified
S & F in repair Al IN-Line connectors of size 25 Sqmm specified
S & F in repair Al IN-Line connectors of size 35 Sqmm as specified
S & F in repair Al IN-Line connectors of size 50 Sqmm as specified
S & F in repair Al IN-Line connectors of size 70 Sqmm as specified
S & F in repair Al IN-Line connectors of size 95 Sqmm as specified
S & F in repair Al IN-Line connectors of size 120 Sqmm as specified
S & F in repair Al IN-Line connectors of size 240 Sqmm as specified
M&L in repair of MCCB, 4 pole, 415 Volts, 63 Amps, 16 KA, 50 Hz, AC, fixed thermal and fixed magnetic type in the existing LT panel board/ sheet metal enclosure including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
M&L in repair of MCCB, 4 pole, 415 Volts, 100 Amps, 16 KA, 50 Hz, AC, fixed thermal and fixed magnetic type in the existing LT panel board/ sheet metal enclosure including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
M&L in repair of MCCB, 4 poles 415 Volts, 160 Amps, 36 kA, 50 Hz, AC, adjustable type type in the existing LT panel board/sheet metal enclosure including connecting up incoming/out going cables with suitable lugs and testing complete all as specified and as directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
M&L in repair of MCCB, 4 poles 415 Volts, 200 Amps, 36 kA, 50 Hz, AC, adjustable type in the existing LT panel board/sheet metal enclosure including connecting up incoming/out going cables with suitable lugs and testing complete all as specified and as directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
M&L in repair of MCCB, 4 poles 415 Volts, 250 Amps, 36 kA, 50 Hz, AC, adjustable type in the existing LT panel board/sheet metal enclosure including connecting up incoming/out going cables with suitable lugs and testing complete all as specified and as directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
M&L in repair of MCCB, 4 pole, 415 Volts, 350 Amps, 36 KA, 50 Hz, AC, adjustable type in the existing LT panel board/ sheet metal enclosure including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
M&L in repair of Power contactor , 3/4 pole, 415 Volts, 265 Amps, 50 Hz, AC fixed in the existing ATS LT panel board including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
M&L in repair of Power contactor , 3/4 pole, 415 Volts, 315/330 Amps, 50 Hz, AC fixed in the existing ATS LT panel board including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
M&L in repair of ON LOAD change over switch with sheet metal enclosure 415V , 4 pole of capacity 250 Amps including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed.. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
M&L in repair of ON LOAD change over switch with sheet metal enclosure, 415V , 4 pole of capacity 315/320 Amps including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed.. Make: HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
S&F in repair of sheet metal enclosure made out of 2mm thick CRCA sheet duly power coated suitable for fixing/mounting MCCB of 160A Amps 4 pole duly fixed on wall with all fixing arangements all as directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
S&F in repair of sheet metal enclosure made out of 2mm thick CRCA sheet duly power coated suitable for fixing/mounting MCCB of 250A Amps 4 pole duly fixed on wall with all fixing arangements all as directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
S&F in repair of MCB TPN 63 A,'C' Curve,10KA rupturing capacity all as specified and as directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
S&F in repair of MCB TPN 40 A, 'C' Curve,10KA rupturing capacity all as specified and as directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
S&F in repair of MCB TPN 100 A,'C' Curve,10KA rupturing capacity all as specified and as directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
S&F in repair of RCCB 63 Amps TPN ,'C' Curve,10KA rupturing capacity having sensitivity 30mA complete all as speified and as directed at site. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
S&F in repair of MCB TPN 125 A,'C' Curve,10KA rupturing capacity all as specified and as directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
S & Fix in repair heavy duty APFC Contactor suitable to switching 15 KVAR capacitor, 3 pole , 415 V rating fixed to existing capacitor bank by taking down the existing un-serviceable contactor complete all as specified and directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
S & Fix in repair of heavy duty APFC Contactor suitable to switching 20 KVAR capacitor, 3 pole , 415 V rating fixed to existing capacitor bank by taking down the existing un-serviceable contactor complete all as specified and directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
M & L for Cleaning, dusting and servicing LT panel ,MCCBS,Bus bars tightening cable connections, replacing of worn out parts such as busbar spout suppourts ,spacers,hinges,locks,glands and connected items/Mechanical parts neonprin gasket as required etc for its smooth functioning including applying Becktrol red solution to the surface of the bus bars and spouts, applying Monoplast compound at the bus bar joints after tightening of joints ,cleaning the disturbed area beneath the LT panel and removing vegitation , debries etc all as specified and directed by the Engineer in charge. (Note:- Rate quoted deemed to include for removing and replacing of defective items such as insulators for busbar, saparators, sleeves, hinges, bolts, nut where required, complete all as specified and directed.
M & L for servicing of ACB 800/1200A rating by disconnect and taking out the breaker after taking power shut down of the respective panel and overhauling/ servicing the ACB by opening all parts and cleaning of electrical contacts with CTC/rust remover, lubricating electrical moving parts with petrolium jelly and mechanical moving parts with grease & applying Becktrol red solution to the surface of the bus bars and spouts, applying Monoplast compound at the bus bar joints after tightening of joints and replacing defective spare parts like springs/ bolts/ nuts/ washers etc, including testing, calibrating , refixing the circuit breaker and make fuctional all as directed and specified
M & L for Painting the LT Panel complete of any capacity after preparation of surface and applying two coats of synthetic enamel (smoke grey) paint and old steel surafce , replace the Danger notice plate, complete all as specified and directed.
S & F in repair of Danger notice plates, made out of 1.6mm thick MS sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT 20X15 cm size, fixed as in repairs, complete all as specified and directed.
S & Fix in repair of APFC micro controller Relay 8 steps fixed to existing APFC panel by taking down the existing un-serviceable relay complete all as specified and as directed. Make:SELEC/HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
S & Fix in repair of Power factor capacitors MPPH type of 5 KVAR rating, fixed to existing capacitor bank including connecting up and testing, complete all as specified and directed.Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
S & Fix in repair of APFC copper HD Harmonic reactor having Class 'H' insulation , low noise,low losses & high harmonic loading capability of 10 KVAR rating, 440V, fixed to existing APFC panel including taking down the existing un-serviceable Reacter and connecting up and including testing complete all as specified and directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
S & Fix in repair of APFC copper HD Harmonic reactor having Class 'H' insulation , low noise,low losses & high harmonic loading capability of 12.5 KVAR rating, fixed to existing APFC panel including taking down the existing un-serviceable Reacter and connecting up and including testing complete all as specified and directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
S & F in repair of Digital Multifunctional Panel meter for measuring Voltage ( 0-500V min ) ,Current , P.F , etc including necessary P.T & C.T's with all connected acccessories all as specified and directed Make : L&T/automatic electric/Secure meter/Havells
S & F in repair of Digital voltmeters 0-500V , with all connected accessories including connecting up and testing as all as specified Make : L&T/automatic electric/Secure meter/Havells
S & F in repair of Digital Ammetr 0-600A (min) , with CT's, all connected accessories including connecting up and testing as all as specified Make : L&T/automatic electric/Secure meter/Havells
S & F in repair of LED indicator lamp 240 V , with suitable colour Red/Blue/Yellow/Amber/Green and connected acccessories all as specified and directed Make : L&T/automatic electric/Secure meter/Havells
S & F in repair of push button switch with NO/NC contacts 415 V ,6A , with add on Aux Contacts and connected acccessories all as specified and directed Make : L&T/Siemens/Havells
S & F in repair of power contactor AC coil 240V ,50Hz suitable for MNX 70 Contactor complete all as specified. Make : L&T/Schneider/Siemens
S & F in repair of power contactor AC coil 240V ,50Hz suitable for MNX110/95/140 Contactor complete all as specified. Make : L&T/Schneider/Siemens
S & F in repair of power contactor AC coil 240V ,50Hz suitable for MNX300/MNX400 Contactor complete all as specified. Make : L&T/Schneider/Siemens
S & F in repair of power contactor AC coil 240V ,50Hz suitable for MCX40/25/32 Contactor complete all as specified. Make : L&T/Schneider/Siemens
S & F in repair of HBC/HRC Fuse up to 32A complete all as specified. Make : LEGRAND/HAVELLS/L&T
S & F in repair of HBC/HRC Fuse 40A to 125A complete all as specified. Make : LEGRAND/HAVELLS/L&T
S & F in repair of HBC/HRC Fuse 200A to 315A complete all as specified. Make : LEGRAND/HAVELLS/L&T
S & F in repair of HBC/HRC Fuse 350A to 400A complete all as specified. Make : LEGRAND/HAVELLS/L&T
S & F in repair of HBC/HRC Fuse 500A to 630A complete all as specified. Make : LEGRAND/HAVELLS/L&T
S & F in repair of outdoor type bus bar chamber of suitable size made out of 3mm thick CRCA steel sheet and 40x5mm angle iron frame with locking arrangement including provision of 250A 4 way Aluminium busbar connecting up incoming and out going cables complete with glands and lugs and testing complete all as specified and as directed. Note: The quoted rate deem to includ the cost of earth work and pcc work and complete connected work
S & F in repair of outdoor type bus bar chamber of suitable size made out of 3mm thick CRCA steel sheet and 40x5mm angle iron frame with locking arrangement including provision of 400A 6 way Aluminium busbar connecting up incoming and out going cables complete with glands and lugs and testing complete all as specified and as directed. Note: The quoted rate deem to includ the cost of earth work and pcc work and complete connected work
S & F in repair of outdoor type bus bar chamber of suitable size made out of 3mm thick CRCA steel sheet and 40x5mm angle iron frame with locking arrangement including provision of 800A 6 way Aluminium busbar connecting up incoming and out going cables complete with glands and lugs and testing complete all as specified and as directed. Note: The quoted rate deem to includ the cost of earth work and pcc work and complete connected work
S & Fix in repair of Saftey protection relay 415 VAC, 3 Ph 4 Wire, 2 C/O with adjustable under voltage,over voltage, on delay,Neutral fail protection for lt Panel all as specified and directed by engineer in charge. Make : L&T Cat No MAC04 D0100 or equivalent in ABB/Siemens
M & L for Repair/Reconditiong of exisitng earth pit by removing damaged Earth PCC chambers and excavate pit soil upto 25% of earth plate/electrode and adding alternate layers of charcoal, mixture of salt and copper sulphate up to 15cm above the earth plate/electrode and moist the mixture using water , cleaning/replacing of funnel with wire mesh where ever necessary , testing the earthing after reconditioning and earth resistance value must be within 1.5 Ohms, making good to distrubed surface and all as specified and directed at site. Note: 1. The quoted rate Deemed to include excavation, returning filling and connected items, 2. Salt, charcoal, copper Sulphate, pit chamber and testing will be measured and paid seperatly
Supply only pure charcoal granular/aggregate type having Ash content < 5% , stone free for earthing
Supply only iodine free pure common salt crystal ( NaCl) for earthing
M & L in repair laying earth continuity conductor GI Strip 25 x 4mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for direct/loop earthing with proper PVC/Porcelain insulator etc all as specified and directed .
M & L in repair damaged earth chamber with pre moulded PCC earth chamber with cast iron cover of size 300mm x300mm x 50mm including provision of funnel, wire mesh necessary excavation and earth work in any type of soil including paninting , marking of earth values with date complete all as specified and directed
S & F in repair of PVC Polymer insulator for existing GI/Aluminium/copper strip support all as specifed and directed
S & Fix in repair of Power factor capacitors MPPH type of 25 KVAR rating, fixed to existing capacitor bank including connecting up and testing, complete all as specified and directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
S & Fix in repair of Power factor capacitors MPPH type of 20 KVAR rating, fixed to existing capacitor bank including connecting up and testing, complete all as specified and directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
S & Fix in repair of Power factor capacitors MPPH type of 10 KVAR rating, fixed to existing capacitor bank including connecting up and testing, complete all as specified and directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
Material & Labour for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to galvanised earth strip of size 25 x 4 mm by means of bolts, nuts and washers of galvanised iron or steel all as shown in elecrtical plate No 3 of SSR pt I, connected to DB/earthing test point including PCC chamber , RCC cover 50mm thick with 8 mm dia bars, protection pipe, funnel etc including excavation, earth work, disposal of surplus soil and earth strip protection pipe of GI 40 mm bore light grade upto 7.5 metre including testing on completion all as specified and as directed.
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 110 mm dia suitable for 0.4 mpa working pressure all as specified and as directed. .
M&L for Boring of holes under road pavement hard standing by manual boring incl making good the disturbed surfaces complete all as specified and directed
S & F Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors, Pole above ground all as specified and as directed.
Material & Labour for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to galvanised earth strip of size 32 x 6 mm by means of bolts, nuts and washers of galvanised iron or steel all as shown in elecrtical plate No 3 of SSR pt I, connected to DB/earthing test point including PCC chamber , RCC cover 50mm thick with 8 mm dia bars, protection pipe, funnel etc including excavation, earth work, disposal of surplus soil and earth strip protection pipe of GI 40 mm bore light grade upto 7.5 metre including testing on completion all as specified and as directed.
M & L for Loose filling with aggregates of gauge 40 mm filling in Panel sarrounding upto 1 to 3 mtr as per ground availability of area, cleaning the area, making level, and filling the aggregate complete all as directed by Engr-in-Charge
M & L for Testing of earthing resistance of existing earthing using calibrated 3/4 wire digital Earth resistance tester and recording the earth resistance value in register obtaining the signature of user and MES excecutive after varification all as specified and directed by Engr-in-Charge Note : Contractor has to provide digital earth resistance tester and should be available all the time during the contract period.
B5BUILDING SOLUTIONS
Jagdamba Engineering
SREE VARU ELECTRICALS
Varsha Enterprises
Pacific Enterprises
RAMSON TRADERS
RRK PROJECTS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .