Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.6 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹44.6 L+₹1.2 L (2.80%)Rejected-AOC | L2 | Rejected-AOC LOWEST BIDDER | |
| 3 | L3₹47.9 L+₹4.5 L (10.4%)Rejected-AOC | L3 | Rejected-AOC OTHER THAN LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹92,000
Closing Date
26 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE of GE SOUTH AKHNOOR
GE SOUTH AKHNOOR C/O 56 APO PIN- 900234
PROVN OF OFFICE ROOM NEAR MAIN OFFICE COMPLEX, PROVN OF ATTACHED TOILET WITH BATHROOM, PROVN OF FOOTPATH, PROVN OF SIDE HIGH WALL AND SPECIAL REPAIR TO BLDG NO TR-02, TR-03, T-01, T-23 (ADS), T-45 (WAHSERMAN SHOP) AT RAKHMUTHI AREA INCLUDING CONSTRUC
2020_MES_335907_2
NIT-01
Open Tender
Civil Works
Item Rate
180 days
RAKHMUTHI AREA
Class D and Category a(i) and b(i)
8 documents required · 8 mandatory
₹500
GE SOUTH AKHNOOR
₹92,000
Yes
20 Oct 2020
29 Aug 2020
28 Sept 2020
29 Aug 2020
26 Sept 2020
14 Sept 2020
60 days
Amount
SCHEDULE 'A' PART-I : BOQ OF WORKS FOR B/R WORKS.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in any type of soil, omplete all as specified and directed.
Excavation in trenches, not exceeding 1.50 mtr wide and not exceeding 1.50mtr in depth; not exceeding 10 Sqm on plan and not exceeding 1.50 mtr in depth and getting out, in any type of soil, for foundation, complete all as specified and as directed by Engineer-In-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25Cm, complete all as specified and directed by Engineer-In-Charge.
Spreading, levelling and ramming in floors, in layers not exceeding 25cm thick, well ramming including watering as required, complete all as specified and directed by Engineer-In-Charge. Note: Volume of removal of excavated materials/ soil shall be deducted in the abstract of quantity.
Removing excavated materials/ soils, to a distance not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed by Engineer-In-Charge.
Plain cement concrete M-7.50(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as mass concrete in foundation, complete all as specified and as directed by Engineer-In-Charge.
Brickwork with subclass ‘B’ bricks, old size bricks, straight or curved on plan exceeding 6.0mtrs mean radius built in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
Cutting openings, through brick walls in cement mortarfor door, window and other openings or enlarging existing openings, converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hardcore, etc, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-5(1:5:10), type E-2 (using 40mm graded crushed stone aggregate), 75mm thick, as in sub base of floors, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-15(1:2:4), type B-0 (using 12.50mm graded crushed stone aggregate), nominal mix, 25mm thick, as in floors, finished even and fair without using extra cement to recieve floor finishes, complete all as specified and as directed by Engineer-In-Charge.
Rendering 15mm thick, on fair faces of brick or concrete surfaces, in cement mortar 1:6, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.
Rendering 15mm thick, on fair faces of brick or concrete surfaces, in cement mortar 1:4, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.
Rendering 10mm thick, on fair faces of brick or concrete surfaces, in cement mortar 1:6, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.
Glazed ceramic tiles in vertical surface/ dado, size 300x450x7mm thick, 400x400x6/7mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match, the shade/ colour of tiles including 10mm thick rendering in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
Non-skid, coloured, ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-15(1:2:4), type B-1, (using 20mm graded crushed stone aggregate), nominal mix, as in copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work, complete all as specified and as directed by Engineer-In-Charge.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and directed by Engineer-In-Charge.
Mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer-In-Charge.
Formwork to rough finish surfaces/ sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, complete all as specified and directed by Engineer-In-Charge.
Formwork for rough finish surfaces to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), complete all as specified and as directed by Engineer-In-Charge.
Reinforced cement concrete M-25(1:1.5:3), type B-1 (using 20mm graded crushed stone aggregate), nominal mix, as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, finished even and fair without using extra cement, complete all as specified and as directed by Engineer-In-Charge.
Hardcore of broken stone stones or boulders, gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-10(1:3:6), type C-1 (using 20mm graded crushed stone aggregate), 50mm thick, as in plinth protection and providing the joints throughout the thickness, filled with mastic filling comprising bitumen 85/25 grade and sand mixture 1:3 by weight, complete all as specified and as directed by Engineer-In-Charge.
Factory made steel window, box type, using ERW hollow 'P' section, comprising double frame for and including gauged and glazed skeleton shutter with wire mesh and glass sheet 3.0mm thick, jointed internally and made with flat iron 40x4mm complete including grill/ guard bars of 8mm square bars fixed horizontally @100mm C/C including mild steel hinges, handles, tower bolts, stops, lugs etc, complete all as specified and as shown in drawing No- CEUZ/TD-1304, sheet No- 1/3 to 3/3 and as directed by Engineer-In-Charge.
Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., size of frame 105x60mm, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-10(1:3:6), type C-1, (using 20mm graded crushed stone aggregate), nominal mix, as in cills, steps; plinth courses, string courses, lacing courses, copings, kneelers, apex stones, bed plates and in hold fasts or filling in hollow of steel frame, including necessary form work, complete all as specified and as directed by Engineer-In-Charge.
Factory made solid panel PVC door shutter with wood free EPS, 30mm thick (style) consisting of frame made out of mild steel tubes for top and bottom rails. Mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of plain colour PVC sheet to be fitted in the mild steel frame welded/ sealed to the stiles and rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame with three Nos of stainless butt hinges of 100mm size and rust proof screws, at site as per specification and drawing, complete all as specified and as directed by Engineer-In-Charge.
Butt hinges, size 100mm, medium weight, cold rolled mild steel, and fixed, complete all as specified and as directed by Engineer-In-Charge.
Aluminium alloy, anodised, sliding door bolt, size 250mm, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10cm width or girth including and applying two coats of synthetic enamel paint over one coat of zinc chrome/ red oxide primer, complete all as specified and as directed by Engineer-In-Charge.
Aluminium anodised, barrel tower bolts of extruded Section, size 200mm long, fixed in repairs, complete all as specified and as directed by Engineer-In-Charge.
Aluminium handles, cast type, anodised, size 150mm, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion over one coat of chalk whiting, on plastered surfaces, preparatory to distempering, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of cement paint over one coat lime wash, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new plastered or unplastered surfaces of ceiling/ walls and applying three coats of white washing, complete all as specified and as directed by Engineer-In-Charge.
Sheet glass, 3.0mm thick, ordinary quality and glazing with oil putty or with wooden beadings, fixing in square not exceeding 0.50Sqm in each pane, complete all as specified and as directed by Engineer-In-Charge.
Vitreous China wash down water closet pan (pedestal pattern), size 670x390x760mm, white, in one peice, design and accessories as per cat part and making good to dismantled/ damaged wall in cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregates), fixing in repairs, complete all as specified and as directed by Engineer-In-Charge. Make: Cera or equivalent in Johnson/ Hindware/ Jaquar.
Vitreous China wash basin, white, flat back, size 550x400mm excluding taps, waste, chain and plug and porcelain stopper including brackets of any size, including cutting for and pinning in ends of brackets or erecting stand including fixing and supply of waste pipe of 32mm dia, waste coupling of PTMT (half or full threaded), fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Low density polyethylene (LDPE) pipes of 32mm bore, pressure rating 6.0 Kgf/Sqcm), 900mm long, complete all as specified and directed by Engineer-In-Charge.
Bib taps, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Centre hole basin mixture for hot and cold water, chromium plated, with round sport without pop up waste system for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge. Make: Cera/ Jaquar/ Parko/ Hindware.
PVC connections 15mm size with brass nuts of length 450mm, complete all as specified and as directed by Engineer-In-Charge.
Angle/ stop valve, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Stop valves (concealed type), cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore pipe, fixed in repairs, complete all as specified and as directed by Engineer-In-Charge.
Brass chromium plated shower rose 125mm size, fancy type, with arms, fixed for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Tubes, 'medium grade' galvanised, 15mm bore, ISI marked with all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-In-Charge.
Tubes, 'medium grade' galvanised, 20mm bore, ISI marked with all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-In-Charge.
Rotational moulded polyethylene water storage tanks of 500 liters capacity, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 20mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.
Brass chromium plated, tubular towel rail, 20mm dia, D type, 60cm long between flanges, fancy type, complete all as specified and as directed by Engineer-In-Charge.
Glass corner shelf, made with 6 to 8mm thick transparent glass, three teirs including anti rust screws, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Hand shower (Health faucet), brass body with 8mm dia and 1.0mtrs long SS braided flexible tube with wall hook, complete all as specified and as directed by Engineer-In-Charge. Make: Cera cat part No- F8030301/ Jaquar cat part No- ALD-CHR-573/ Riviera cat part No-S1627C.
PVC (SWR) bends of 110mm bore, pressure capacity not less than 4.50 Kgf/Sqcm, any radius, fixing with adhesive, complete all as specified and as directed by Engineer-In-Charge.
Soap dish, fancy type, fixed to plugs with chromium plated brass screws, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Toilet paper holder, fancy type and chromium plated, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
PVC (SWR) bends of 75mm bore, pressure capacity not less than 4.50 Kgf/Sqcm, any radius, fixing with adhesive, complete all as specified and as directed by Engineer-In-Charge.
Stainlees steel grating, chromium plated, size 125mm, heavy duty, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
PVC (SWR) pipes, 75mm bore, pressure capacity not less than 4.50 Kgf/Sqcm, single socketed, in any length with rubber ring joints, laid in trenches, complete all as specified and as directed by Engineer-In-Charge.
PVC (SWR) pipes, 75mm bore, pressure capacity not less than 4.50 Kgf/Sqcm, single socketed, in any length with rubber ring joints, fixed on wall with mild steel/ PVC clamps, complete all as specified and as directed by Engineer-In-Charge.
PVC (SWR) pipes, 110mm bore, pressure capacity not less than 4.50 Kgf/Sqcm, single socketed, in any length with rubber ring joints, laid in trenches, complete all as specified and as directed by Engineer-In-Charge.
PVC (SWR) floor trap of 75mm dia outlet, plain with grating including jointing with solvent cement, complete all as specified and as directed by Engineer-In-Charge.
PVC (SWR) junction single, (Single T) equal or unequal, of 110mm bore, fixing with adhesive, complete all as specified and as directed by Engineer-In-Charge.
Water proof treatment on roof top with APP (Ataxic Poly Propylene) modified polymeric five layered membrane with central core of 100 micron high molecular high density polyethylene film, minimum weight not less than 3.0 Kg/ Sqm, 2.0mm thick, centre core is sandwiched on both sides by high quality polymeric mix with properties of high softening point, high heat resistance and cold resistivity to make it ideal for all water proofing treatment, with polymeric mix protection on both sides with 20 micron HMHDPE film, laid over one coat of bituminous primer conforming to IS: 3384, applied @0.40 Kg/ Sqm and one coat of hot blown bitumen of 85/25 grade, conforming to IS:702, applied @1.20Kg/ Sqm on prepared surfaces of roof, overlap should be not less than 150mm at ends and 75mm at sides, joints and overlaps uniformly bounded with LPG torch flame including applying of one coat of semi hot blown bitumen of 85/25 grade, @1.20 Kg Sqm and fine screened sand in dry condition @0.50 Kg/ Sqm after laying the membrane, complete all as specified and as directed by Engineer-In-Charge.
Rendering 10mm thick on fair faces of brick work or concrete surfaces, in cement mortar 1:4, including mixing water proofing compound @ 3% by weight in cement, rendering is to be finished even and smooth (without using extra lime or cement), complete all as specified and as directed by Engineer-In-Charge. Note: Cost of water proofing compound shall deemed included in quoted rates.
Applying one coat of neat cement slurry with 3.0 Kg of cement per Sqm on cleaned new surfaces of roof, evenly, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-10(1:3:6), type C-2 (using 40mm crushed stone aggregates) as in bed to drain pipes of 150mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; after laying, complete all as specified and as directed by Engineer-In-Charge.
Salt-glazed stoneware drain pipes, internal 150mm, laid in trenches and jointed in cement mortar 1:1, complete all as specified and as directed by Engineer-In-Charge.
Brickwork with subclass ‘B’ bricks, old size bricks, straight or curved on plan exceeding 6.0mtrs mean radius built in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
Precast reinforced cement concrete M-20(1:1.5:3), type A-1, (using 20mm graded crushed stone aggregate), nominal mix, as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs and similar articles with plain faces as specified in clause No- 4.11.16 of SSR Part-I (2009), set in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
Septic tank for 25 users LLDPE (Linear Low Density Polyethylene) with upflow filter including media type with vent pipe, cowl etc. designed to carry sewage and sullage water, including excavation in any type of soil as per size of tank , PCC 1:4:8 Type D-2(using 40mm graded crushed stone aggregates)as bed concrete, lowering the septic tank and filling with water and return/filling with mix of coarse sand and Bajri around the septic tank and do inlet and outlet pipe connection etc complete all as specified and as directed. Make: Sintex /Comfort polymers/ Polycon.
Construction of soakage well of 1.2 mtrs dia and 3.0 mtrs in depth, in any type of soil including plain cement concrete M-10(1:3:6), type C-2 (using 40mm graded crushed stone aggregates) in foundation and honeycombed brick masonry in cement mortar 1:4 and reinforced cement concrete cover slab, M-25, type A-1 (using 20mm graded crushed stone aggregates), complete all as specified and as shown in drawing. Drawing No- CE/TD/1202/03 sheet 1/2 and 2/2 dated 09.10.03 revised 14.10.14 and 11.05.07.
Plain cement concrete M-7.50(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), 100mm thick, as in sub base of floors, finish even to recive floor finishes, complete all as specified and as directed by Engineer-In-Charge.
Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, laid over 25mm thick well rammed sand cushion, with grey cement and no pigment, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-10(1:3:6), type C-2 (using 40mm graded crushed stone aggregate) in surface channels and drains, complete all as specified and as directed by Engineer-In-Charge.
Supply only of integral waterproofing compound, complete all as specified and as directed by Engineer-In-Charge.
Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
Keyed pointing in cement mortar 1:4 to brick work, complete all as specified and as directed by Engineer-In-Charge.
Extra for forming fair finished drain or channel 30 Cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc., complete all as specified and as directed by Engineer-In-Charge.
Extra for forming fair finished drain or channel 45 Cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc., complete all as specified and as directed by Engineer-In-Charge.
Rendering 5mm thick, on fair faces of brick or concrete surfaces, in cement mortar 1:3, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.
Factory made, 35mm thick, second class hardwood, plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new or previously untreated wood or wooden surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and as directed by Engineer-In-Charge.
Dura tuff pave-n-park cement concrete coloured tiles size 300mmx300mmx6/7mm, with chequered finish, laid in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over 15mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
Pre-cast cement concrete block, M-15(1:2:4), type B-1 (using 20mm crushed stone aggregates) as in masonry with solid blocks, exceeding 10cm in width and setting in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
Rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, complete all as specified and as directed by Engineer-In-Charge.
Expanded metal, weight not exceeding 4.0 Kg/Sqm, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members, complete all as specified and as directed by Engineer-In-Charge.
Mild steel work in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron filletsincluding embeding in concrete and screwing etc. wind ties for roof including securing bolts; including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-15(1:2:4), type B-2 (using 40mm graded crushed stone aggregate), 150mm thick, as in sub base of floors, finish even to recive floor finishes, complete all as specified and as directed by Engineer-In-Charge.
Forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’, for thickness of slab 150mm, complete all as specified and as directed by Engineer-In-Charge.
Dismantling of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified.
Brickwork with subclass ‘B’ bricks, old size bricks, straight or curved on plan exceeding 6.0mtrs mean radius built in cement mortar 1:4, but except bricks, complete all as specified and as directed by Engineer-In-Charge.
Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings, complete all as specified.
Rolled mild steel sections as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, conforming to Fe 410-W (Gde- E- 250) quality-A, complete all as specified and as directed by Engineer-In-Charge.
Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-In-Charge.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-In-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets, complete all as specified and as directed by Engineer-In-Charge.
Providing and fixing everest board 4mm thick, designer, in ceiling fixed as per manufacturer’s instructions, including powder coated galvanised iron snap grid frame work of main and tee (weight not less than 240gm/Rm), angle (weight not less than 217 gm/Rm), grid size 595x595mm, for false ceiling all as specified, and hangers 6mm dia, galvanised iron (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of galvanised iron wire of 4.0mm dia, length as required at site and expansion hold fasteners 12.50mm dia, 40mm long, complete all as specified and as directed by Engineer-In-Charge.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc, complete all as specified and as directed by Engineer-In-Charge.
Hacking out old broken glass (any thickness, size, quality or description) from wooden/ steel frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, complete all as specified and directed by Engineer-In-Charge.
Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, fixed in repairs, complete all as specified and as directed by Engineer-In-Charge.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), including cleaning, removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed by Engineer-In-Charge.
Machine cut kota stone slab, (minimum size shall be 550x550mm), flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, and including laid over screed bed or bedding layer of mortar 20mm thick in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sqm each, complete all as specified and as directed by Engineer-In-Charge.
Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and as directed by Engineer-In-Charge.
Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exceeding 4.0 Sqm each, complete all as specified and as directed by Engineer-In-Charge.
Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., size of frame 125x60mm, complete all as specified and as directed by Engineer-In-Charge.
Factory made, glazed and skeleton shutters in second class hardwood, 35mm thick, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats, complete all as specified and as directed by Engineer-In-Charge.
Aluminium alloy, anodised, sliding door bolt, size 300mm, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and as directed by Engineer-In-Charge.
Extruded aluminium alloy handles, fabricated type, anodised, size 125mm, complete all as specified and as directed by Engineer-In-Charge.
Floor door stopper of cover plate 140mm, aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified and as directed by Engineer-In-Charge.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including any pattern roof coverings, complete all as specified and directed by Engineer-In-Charge.
Dismantling timber scantlings 40Sqcm and over in section, in any position and in unframed work, complete all as specified and directed by Engineer-In-Charge.
Rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, conforming to Fe-410 (Gde-E-250) quality-B, complete all as specified and as directed by Engineer-In-Charge.
Brickwork with subclass ‘B’ bricks, old size bricks, straight or curved on plan exceeding 6.0mtrs mean radius built in cement mortar 1:6, but except bricks, complete all as specified and as directed by Engineer-In-Charge.
Preparation of old/ decorated plastered or unplastered surfaces of walls and applying one coat of distemper oil emulsion, complete all as specified and as directed by Engineer-In-Charge.
Preparation of old/ decorated plastered or unplastered surfaces of walls and applying one coat of cement paint, complete all as specified and as directed by Engineer-In-Charge.
Aluminium anodised, barrel tower bolts of extruded Section, size 150mm long, fixed in repairs, complete all as specified and as directed by Engineer-In-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed by Engineer-In-Charge.
PVC (SWR) vent cowl, of 75mm bore, fixing with adhesive, complete all as specified and as directed by Engineer-In-Charge.
Second class hardwood in scantlings, clean sawn and fixed in unframed work, complete all as specified and as directed by Engineer-In-Charge.
Non-skid, coloured, ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
Second class hardwood in scantlings, clean sawn and fixed in unframed work, but except wood/ timber, complete all as specified and as directed by Engineer-In-Charge. Note: Old timber/ wood shall used as retrieved from dismantling.
Preparation of old painted wood/ wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and as directed by Engineer-In-Charge.
Mild steel, 300mm, ordinary rat tail rod pattern springs including roller and roller plate, complete all as specified and as directed by Engineer-In-Charge.
Demolition of cement concrete (reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), including cleaning, removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed by Engineer-In-Charge.
Granite (of any type) work (table rubbed and polished), 15-18mm thick, as in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and as directed by Engineer-In-Charge.
Preparation of old painted steel surfaces of any description, not otherwise described, over 10cm width or girth including and applying one coat of synthetic enamel paint, complete all as specified and as directed by Engineer-In-Charge.
Vitreous China squatting pan, ‘Orissa’ pattern, size 580x440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) but including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good to dismantled floor in cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregates), fixing in repair, complete all as specified and as directed by Engineer-In-Charge.
PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, capacity 10.0 litres and making good to dismantled/ damaged floor/ surfaces, fixing in repair, complete all as specified and as directed by Engineer-In-Charge.
Stop valve of PTMT any colour high pressure screwed for iron pipe and fixed for 20mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.
Rotational moulded polyethylene water storage tanks of 1000 liters capacity, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 20mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.
Waste fittings, brass, chromium plated size 32/ 40mm dia, for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed
Pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed for 15mm bore pipe, fixed in repair, complete all as specified and as directed by Engineer-In-Charge.
PVC (SWR) multi floor trap of 75mm dia with grating including jointing with solvent cement, complete all as specified and as directed by Engineer-In-Charge.
SCHEDULE 'A' PART-II : BOQ OF WORKS FOR E/M WORKS.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and as directed by Engineer-In-Charge.
Point wiring for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
Description all as serial item No- 139.00 here-in-before but for one 3- pin, 5-Amps, socket outlet on same board.
Description all as per serial item No- 139.00 here-in-before but for one 3-pin socket outlet 5-Amps on the independent board.
Point wiring for 3-pin, 15 Amps, switch socket combination on independent board with 2.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 2.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
Disconnecting the electric connections and taking down distribution boxes (any type) including MCBs and making good to the disturbed surfaces to match the existing surface, complete all as specified and as directed by Engineer-In-charge.
Switch piano, flush type, single pole, one way, 5 Amps, complete all as specified and as directed by Engineer-In-Charge.
Switch piano, flush type, single pole, one way, 15 Amps, complete all as specified and as directed by Engineer-In-Charge.
Socket outlet, 2-in-1, 3-pin, 5-Amps, flush type, complete all as specified and as directed by Engineer-In-Charge.
Socket outlet, 2-in-1, 3-pin, 5 and 15 Amps, flush type, complete all as specified and as directed by Engineer-In-Charge.
Ceiling rose, three phase/ PVC/ polycarbonate, isolated body, complete all as specified and as directed by Engineer-In-Charge.
Lamp holder, PVC Polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-In-Charge.
LED retrofit lamp, T-shape, capacity 12 Watt, B-22 holder base with ploycarbonate body and aluminium heat sink, warm/ white light, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- NU Bulb Plus 12 W 865 B22 3 Star (Ordering code-LHLDEUECNL8R012)/ Philips/ Osram/ Crompton.
Stepped type (multi-steps) electronic regulator for ceiling fan 1200 mm, 240 volts, 100 Watts, single pole, including connecting, complete all as specified and as directed by Engineer-In-Charge.
LED tube light fitting, 18 watt, indoor decorative aluminium extruded T5 LED battens, including LED lamp 18 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- E-Lite LED Pride Plus Neo LHEXBTP7IN1W018/ Crompton cat part LCTL-18-CDL/ Bajaj product code-12410, luminaire type- BCLSB 18 NW.
Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 12-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.
MCB, Single Pole and Neutral, 63 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
MCB, Single Pole and Neutral, 32 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, including necessary incoming and out going electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
Street light fitting, Pressure die-cast IP 66 LED street light, including LED lamps of 30 to 36 Watt and connecting up with twin core twisted flexible copper conductor cable with suitable size, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- Endura Pearl SL30WLED757SASYTOPCMP/ Philips ordering code No- 910925863567 (Product Code: 871869637692800)/ Bajaj cat part No- 169913 .
Desert cooler, electric driven copper wounded motor, single phase, 500mm metallic sweep cooler fan, 1400 rpm, 230 Volt, 50 Hz, air delivery capacity 4500 Cum/Hr, three speed regulator (high/medium/low) with metallic blade and mild steel body, duly painted with synthetic anti-corrosive oven cured paint, submersible pump 40 Watt (approx.), speed 1300 rpm, 230 Volts, 50 Hz and including wood wool pad of proper thickness and 2.50Sqmm three core copper wire with connecting top plug, complete all as specified and as directed. Make of motor: Khaitan/ Usha Lexus/ Orient/ Crompton.
House service bracket for mounting light fittings House service bracket any type complete with 1.50mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed by Engineer-In-Charge.
Switch socket combination, 2-in-1, 3-pin, 5-Amps, flush type, complete all as specified and as directed by Engineer-In-Charge.
Sub main wiring (concealed conduits to surfaces) for circuits/ submain wiring alongwith earth wire with two run of 4.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 2.50 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge.
Description all as serial item No- 1.61 here-in-before but for sub main wiring (in new conduits concealed to surfaces) alongwith earth wire with two run of 6.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 4.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts.
Ceiling fan, mettalic, sweep 1200mm, superior rating for energy saving, mettalic blades, copper wounded motor complete with electronic fan regulator including hanging accessories i.e. U-clamp, down rod, canopy and nut bolts, washers, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- FHCES5SWHT48/ Crompton Greaves Entrust 50/ Usha Ergo/ Bajaj Electra 50/ Orient Electric energy star
Plug and socket board, metal enclosure with 2-pole and earth, including MCB 20 Amps Single Pole and Neutral and all internal wiring with copper wire, making necessary connections, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- DHDPUSN020/DHDPUDP020 or equivalent in ABB/ Legrand/ L&T.
Environmental friendly, ultra modern, energy saving, surface mounted, decorative bulk head back-lit LED luminaire comprising of high brightness LEDs lamp of 15 Watt, complete all as specified. Make: Compact ordering cat part No- HEXAFT10WLED857SSYMBOPC or equivalent in Crompton/ C&S/ Bajaj.
Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 10.0 Sqmm, 2.0-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed by Engineer-In-Charge.
GI pipes/ Tubes, 'light grade', galvanised, 40mm bore, ISI marked, laid in trenches or fixed to walls/ poles with mild steel clamps, nuts, bolts and washers; for protection of electric cable, complete all as specified and as directed by Engineer-In-Charge.
Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified and directed by Engineer-In-Charge.
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed by Engineer-In-Charge. Note: Punned thickness shall be measured.
Switch socket combination 2-in-1, 3-pin, 5 and 15 Amp flush type universal type, complete all as specified and as directed by Engineer-In-Charge.
Exhaust fan, mettalic, sweep 250/ 230mm, superior rating for energy saving, mettalic blades, copper wounded motor complete with electronic fan regulator including hanging accessories i.e. U-clamp, down rod, canopy and nut bolts, washers, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- FHVDBMTGRY09 (Ventilair DB Neo)/ Crompton Greaves/ Usha/ Bajaj/ Orient.
Earthing complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with 4.0mm dia GI wire as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 20mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed by Engineer-In-Charge. Note: Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces.
LED retrofit lamp, capacity 7 Watt, B-22 holder base with ploycarbonate body and aluminium heat sink, warm white, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- LED ADORE 7 W B22 WW 3 STAR LAMP or equivalent in Bajaj/ Philips/ Wipro.
Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 4-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.
House service bracket for mounting light fittings House service bracket (hook type complete with 3.0mtr long galvanised iron pipe 40mm dia medium grade, two Nos 90° bends including mild steel clamps, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed by Engineer-In-Charge.
PVC insulated FRLS cable with multi-stranded copper conductor 1100 volt grade, size 6.0 Sqmm, twin core, insulated cable for connection from MCB distrubition board to Electric Meter by using clips in Meter box, including 20mm dia PVD rigid conduit, complete all as specified and as directed by Engineer-In-charge. Note: Two runs of cable and one one run of PVC conduit 30mm dia, ISIS marked, shall be measured as one unit of length.
Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 20mm bore pipe, complete all as specified and directed by Engineer-In-Charge.
Drilling and tapping CI/ DI/ GI water mains (in position) the existing pipe of 20/ 25mm for branch connections including inserting tee of size 25x25x20mm with all fittings complete all as specified and as directed.
Bell push switch, single pole, one way, flush type, 5-Amps, 240 volts, complete all as specified and as directed by Engineer-In-Charge.
Door bell, AC, 230 Volts, single pole, ding-dong type sound, completeall specified and as directed by Engineer-In-charge.
Tubes, 'medium grade' galvanised, 20mm bore, ISI marked with all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc and laid in trenches, complete all as specified and as directed by Engineer-In-Charge.
Amount of Schedule of credit of for Rs 90,766.00 shall be deducted from quoted amount.
M/S SAHNI CONSTRUCTION CO
M/s Mool Raj Romesh Chander
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .