| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹121.8 CrAccepted-AOC THIRD FLOOR AMIT CRYSTAL SENAPATI BAPAT ROAD PUNE 411 016 | PUNE | PUNE | MAHARASHTRA | 411016 | ₹121.8 Cr | L1 | Accepted-AOC Ist Lowest |
| 2 | L2₹125.3 CrRejected-AOC HARSH ANAND YEVALEKAR MALA COLLEGE ROAD NASHIK 422005 | NASHIK | NASHIK | MAHARASHTRA | 422005 | ₹125.3 Cr | L2 | Rejected-AOC Rejected-AOC |
| 3 | L3₹127.5 CrRejected-Finance | ₹127.5 Cr | L3 | Rejected-Finance L3 |
Tender Value
₹110.4 Cr
EMD Value
₹56 L
Closing Date
13 Sept 2021, 6:00 pmClosed
E.E.P.W.EAST DIVISION PUNE
E.E.P.W.EAST DIVISION PUNE
Construction of Sub District Headquarters for Police Dept. at post Barhanpur for SP (Pune Rural) Tal Baramati Dist Pune
2021_PWDRP_714171_1
E. Tender Notice No. 27 for 2021-2022
Open Tender
Civil Works - Buildings
365 days
Baramati
Please refer Tender documents.
4 documents required · 4 mandatory
₹11,200
₹56 L
Chief Engineer, P. W. Region Office,Pune
24 Nov 2021
26 Aug 2021
16 Sept 2021
26 Aug 2021
13 Sept 2021
26 Aug 2021
31 Aug 2021
Amount
Labour charges for removing grass, thorney shrubs, Jungli shrub, Kubabul and alike grass along roadside making the ground clean by showel and phavaras etc. complete
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. for all leads & lifts ,By Mechanical Means
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. for all leads & lifts By Mechanical Means
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete for all leads & lifts By Mechanical Means
Excavation for foundation in Hard rock by blasting including trimming and leveling the bed by chiseling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the building area including dewatering and back filling with available earth/murum, watering, ramming, etc. complete. for all leads & lifts By Mechanical Means
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper.
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete.
Filling in plinth and floors with approved excavated material in 15cm. to 20cm. layers including watering and compacting etc. complete
Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete
Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete.
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to beprovided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processorbased PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Ground Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processorbased PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) First Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processorbased PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Second Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Ground Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) First Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Second Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Ground Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) First Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Second Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Ground Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) First Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Second Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Ground Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) First Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Second Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Ground Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) First Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Second Floor
Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Ground Floor
Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) First Floor
Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Second Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / granite /gneiss / quartzite metal for R.C.C. fins of required thickness in position as shown on the drawings or as directed by Engineer-in-charge including steel centering, plywood / steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Ground Floor
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete Ground Floor
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required completeFirst Floor
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete Second Floor
Providing and fixing during laying in RCC Slab rectangular 2 mm thick M.S. sheet fan hook box of size 180x100 mm with required depth with holes or notches as required, bottom and top sides of 1.6 mm M.S. sheet fixed with 3.5 mm dia. round headed screws together with 12 mm dia. M.S. bar bent to shape with hooked ends for fan hook and painting to exposed surface Ground Floor
Providing and fixing during laying in RCC Slab rectangular 2 mm thick M.S. sheet fan hook box of size 180x100 mm with required depth with holes or notches as required, bottom and top sides of 1.6 mm M.S. sheet fixed with 3.5 mm dia. round headed screws together with 12 mm dia. M.S. bar bent to shape with hooked ends for fan hook and painting to exposed surface First Floor
Providing and fixing during laying in RCC Slab rectangular 2 mm thick M.S. sheet fan hook box of size 180x100 mm with required depth with holes or notches as required, bottom and top sides of 1.6 mm M.S. sheet fixed with 3.5 mm dia. round headed screws together with 12 mm dia. M.S. bar bent to shape with hooked ends for fan hook and painting to exposed surface Second Floor
Providing and constructing masonry in Autoclaved Areaclaved ( Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size ( 625x240x225)mm in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in superstucture including,striking joints,racking out joints watering and scaffolding etc.complete Ground Floor
Providing and constructing masonry in Autoclaved Areaclaved ( Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size ( 625x240x225)mm in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in superstucture including,striking joints,racking out joints watering and scaffolding etc.complete First Floor
Providing and constructing masonry in Autoclaved Areaclaved ( Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size ( 625x240x225)mm in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in superstucture including,striking joints,racking out joints watering and scaffolding etc.complete Second Floor
Providing and constructing masonry in Autoclaved Areaclaved (Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size (625x 240x100)mm in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in half brick thick wall including 2 hoop iron strips 25mm x 1.6mm at every third course,properly bend and bonded at ends scaffolding racking out joints and watering compete Ground Floor
Providing and constructing masonry in Autoclaved Areaclaved (Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size (625x 240x100)mm in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in half brick thick wall including 2 hoop iron strips 25mm x 1.6mm at every third course,properly bend and bonded at ends scaffolding racking out joints and watering compete First Floor
Providing and constructing masonry in Autoclaved Areaclaved (Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size (625x 240x100)mm in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in half brick thick wall including 2 hoop iron strips 25mm x 1.6mm at every third course,properly bend and bonded at ends scaffolding racking out joints and watering compete Second Floor
Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete Ground Floor
Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter / two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc. complete. Ground Floor
Providing and applying gypsum plaster ( with Gypsum material of Gypsum India / Mega Sign or equivalent make ) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete. Ground Floor
Providing and applying gypsum plaster ( with Gypsum material of Gypsum India / Mega Sign or equivalent make ) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete. First Floor
Providing and applying gypsum plaster ( with Gypsum material of Gypsum India / Mega Sign or equivalent make ) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete. Second Floor
Providing and applying plaster with plaster of paris in 6mm thickness to previously plaster surface in all position including preparing the surface scaffolding etc. complete. Ground Floor
Providing and applying plaster with plaster of paris in 6mm thickness to previously plaster surface in all position including preparing the surface scaffolding etc. complete. First Floor
Providing and applying plaster with plaster of paris in 6mm thickness to previously plaster surface in all position including preparing the surface scaffolding etc. complete. Second Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Ground Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. First Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Second Floor
Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required, in all position including preparing the surface, scaffolding etc. complete Ground Floor
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. Ground Floor
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. First Floor
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. Second Floor
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. Ground Floor
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. First Floor
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. Second Floor
Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. Ground Floor
Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. First Floor
Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. Second Floor
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. Ground Floor
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. First Floor
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. Second Floor
Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete. Ground Floor
Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete. First Floor
Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete. Second Floor
Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete. One side polish Ground Floor
Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. Ground Floor
Providing leather finished polishing to Kota / Marble / Shahabad / Kadappa Stone slab by continuous grinding in 4 coats of different bits to receive rough and matty finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete. Ground Floor
Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete Ground Floor
Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete First Floor
Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. Ground Floor
Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. First Floor
Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. Second Floor
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. Ground Floor
Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete Ground Floor
Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete First Floor
Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete Second Floor
Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. Ground Floor
Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. First Floor
Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. Second Floor
Providing and laying Vitrified MATT finish having decorative type of size 1000 millimeter x 1000 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical and confirming to IS 15622-2006 (Group Bla) of approved make shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints curing and cleaning etc .complete. Ground Floor
Providing and laying Vitrified MATT finish having decorative type of size 1000 millimeter x 1000 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical and confirming to IS 15622-2006 (Group Bla) of approved make shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints curing and cleaning etc .complete. First Floor
Providing and laying Vitrified MATT finish having decorative type of size 1000 millimeter x 1000 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical and confirming to IS 15622-2006 (Group Bla) of approved make shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints curing and cleaning etc .complete. Second Floor
Providing and laying Vitrified MATT finish having decorative type of size 600 millimeter x 600 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical and confirming to IS 15622-2006 (Group Bla) of approved make shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints curing and cleaning etc .complete Ground Floor
Providing and laying Vitrified MATT finish having decorative type of size 600 millimeter x 600 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical and confirming to IS 15622-2006 (Group Bla) of approved make shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints curing and cleaning etc .complete First Floor
Providing and laying Vitrified MATT finish having decorative type of size 600 millimeter x 600 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical and confirming to IS 15622-2006 (Group Bla) of approved make shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints curing and cleaning etc .complete Second Floor
Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete Ground Floor
Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete First Floor
Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm to 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning. etc. complete. Ground Floor
Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm to 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning. etc. complete. First Floor
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m) Ground Floor
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m) First Floor
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m Second Floor
Providing and fixing black kadappa stone as shelves 25mm. thick machine polished, extending the polish upto 20 cm width on lowerside, rounding corners, laying in position jointing with bedding cement mortar 1:4 proportion curing etc etc. complete Ground Floor
Providing and applying impression 24 carrat Luxury paint of approved make & approved brand Emulsion paint to interior walls and ceilings of approved quality, colour and shade to new surface in two coats, including sub surface prparation by Acrylic putty and Acrylic primer coats including scaffolding, preparing the surface. etc. complete (Low VOC). Ground Floor
Providing and applying impression 24 carrat Luxury paint of approved make & approved brand Emulsion paint to interior walls and ceilings of approved quality, colour and shade to new surface in two coats, including sub surface prparation by Acrylic putty and Acrylic primer coats including scaffolding, preparing the surface. etc. complete (Low VOC). First Floor
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. Ground Floor
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. First Floor
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. Second Floor
Providing and applying Royale Luxury Emulsion of approved make on internal wall surface as detailed below Scrapping for surface with emery paper and wipe clean for area. wall primer with brush by adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dry for 6 to 8 hoursAfter applying Asian / Berger / Nerolac / Dulex Paints or equivalent acrylic wall putty with appropriate prpportion of water of allow to dry for period of 4 to 6 hours of activity. Scrapping with emery paper and wipe clean Applying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45% or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45 % or 65 to 70 % by roller. (With prior approval of S.E.) Ground Floor
Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. Ground Floor
Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. First Floor
Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. Second Floor
Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. Ground Floor
Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. First Floor
Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. Second Floor
Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use) Ground Floor
Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use) First Floor
Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use) Second Floor
Providing and fixing fiber glass reinforced polyster door shutter 35 mm thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc complete. Ground Floor
Providing and fixing fiber glass reinforced polyster door shutter 35 mm thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc complete. First Floor
Providing and fixing fiber glass reinforced polyster door shutter 35 mm thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc complete. Second Floor
Providing and applying top coat exterior paint to terrace of approved make, shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing surface by throughly cleaning of oil, grease, dirt and other material and fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) preparing as required, etc. complete. Ground Floor
Providing and applying top coat exterior paint to terrace of approved make, shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing surface by throughly cleaning of oil, grease, dirt and other material and fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) preparing as required, etc. complete. First Floor
Providing and applying top coat exterior paint to terrace of approved make, shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing surface by throughly cleaning of oil, grease, dirt and other material and fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) preparing as required, etc. complete. Second Floor
Bamboowood 10mm thick Wall Cladding including Threshold & T-mold - Providing & fixing in position Phenol bonded Bamboowood wall cladding at all height with planks of sizes 10mm thick, 1900mm length (minimum) and 135mm wide approved colour, texture and finish, having Performance Appraisal Certificate (PAC) issued by Building materials & Technology Promotion Council (BMTPC). with necessary profiled edges fixed with BR nails to frame work made of second class teak wood of size 50 x 50mm in centre and ends of each tile. The bamboowood cladding shall be laid over teak wood frame and hold in place by 50mm thick teak wood placed in centre of two teak wood and backlayment and covered with 1.00mm thick expanded poly ethylene foam of density 25Kilogram/cum in two layers first layer on wall surface before fixing wooden frame and second layer on frame under cladding. The Bamboowood planks shall have minimum density of 1000 Kilogram/cum & minimum Hardness 1000 Kilogramf. with Eco friendly UV coating, all complete as per direction of Engineer in-charge. Ground Floor
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. Ground Floor
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. First Floor
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. Second Floor
Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top,40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating ,fixtures, errecting , necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete Ground Floor
Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top,40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating ,fixtures, errecting , necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete First Floor
Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top,40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating ,fixtures, errecting , necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete Second Floor
Providing and fixing in position (as per 1868 / 1982) Alluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/Running metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/Running metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight o.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising with box Ground Floor
Providing and fixing in position (as per 1868 / 1982) Alluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/Running metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/Running metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight o.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising with box First Floor
Providing and fixing in position (as per 1868 / 1982) Alluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/Running metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/Running metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight o.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising with box Second Floor
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. Ground Floor
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. First Floor
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. Second Floor
Providing and fixing in position aluminium partly openable and partly fixed window of any size as per detailed drawing and as directed by Engineerincharge with all necessary alluminium sections including necessary fixtures and fastening with 5 mm thick float glass etc. complete. b) With powder coating Note While arriving at the rate of item of item weight at 6.90 Kilogram/Square Metre is considered Ground Floor
Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Ground Floor
Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. First Floor
Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Second Floor
Providing and fixing M.S. grill door 24 Kilogram/Square Metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc Ground Floor
roviding and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete Ground Floor
roviding and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete First Floor
roviding and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete Second Floor
Providing and fixing Country cut teak wood single leaf panelled door shutter without fanlight and 25mm thick as per drawing consisting of T.W. top rail size 100mm x 25mm and bottom lock rail 200mm x 25mm insert pannel 12 mm thick commercial ply faced T.W. particle board with phenol formaldehyde synthetic resin (Generally confirming to ISI 3097) excluding frame, including stainless steel fixture and fastening and T.W. beading to junctions of panelled inserts and as instructed by the Engineer in charge including 3 coats of oil painting etc. complete. Ground Floor
Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete Ground Floor
Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete First Floor
Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete Second Floor
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear) Ground Floor
Providing and fixing heavy duty inter locking concrete Grey paving blocks of 80 mm thickness of having a strength of 300 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete. Ground Floor
Supply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each not less than 0.50 mm thick, total thickness of aluminium composite panels not to be less than 4 mm, the exposed surface thereof shall have Stove lacquered finishing coat not less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50 mm X25mm X 3mm thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 mm X 1200 mm and fixed to the building structure as per design through 50mm X50mm X5 mm MS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge. (Prior permission of S.E. is necessary before inclusion of this item in estimate) Ground Floor
Supply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each not less than 0.50 mm thick, total thickness of aluminium composite panels not to be less than 4 mm, the exposed surface thereof shall have Stove lacquered finishing coat not less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50 mm X25mm X 3mm thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 mm X 1200 mm and fixed to the building structure as per design through 50mm X50mm X5 mm MS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge. (Prior permission of S.E. is necessary before inclusion of this item in estimate) First Floor
Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete. Spec. Number : As directed by Engineer-in-charge. Ground Floor
Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete. Spec. Number : As directed by Engineer-in-charge. First Floor
Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete. Spec. Number : As directed by Engineer-in-charge. Second Floor
Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. Ground Floor
Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm centerto-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/Square Metre) Ground Floor
Providing and Fixing Rollar Blinds AMI Make or approved make & shade of 38mm round Aluminium channel with Blackout fabric & telting with chain (Ball) system with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work) First Floor
Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. Ground Floor
Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. First Floor
Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. Second Floor
Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systems with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systems with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.products approved as per GRIHA and BS 476 etc. complete. Ground Floor
Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systems with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systems with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.products approved as per GRIHA and BS 476 etc. complete. First Floor
Providing and fixing Indian teak wood plank ceiling 20 mm thick plain underside tongued and grooved including iron screws, scaffolding, if necessary, including one primer coat on under side and one coat of coal tar on upper side etc. complete Ground Floor
Providing and fixing Indian teak wood plank ceiling 20 mm thick plain underside tongued and grooved including iron screws, scaffolding, if necessary, including one primer coat on under side and one coat of coal tar on upper side etc. complete First Floor
Providing and fixing frame work of anodised aluminium sections for suspended false ceiling consisting of aluminium T 50 mm x 40 mm weighing 0.39 Kilogram/m. at 60 cms c/c and fixed with ( 15 x 15 mm) flanges weighing 0.119 Kilogram/m suspended on 6 mm dia. mild steel rod weighing 0.22 Kilogram/m fixed on wall and beams including rounding of the edges with aluminium T of 50 mm x 40 mm weighing 0.39 Kilogram/m etc. including all labour etc. complete. Ground Floor
Providing and fixing frame work of anodised aluminium sections for suspended false ceiling consisting of aluminium T 50 mm x 40 mm weighing 0.39 Kilogram/m. at 60 cms c/c and fixed with ( 15 x 15 mm) flanges weighing 0.119 Kilogram/m suspended on 6 mm dia. mild steel rod weighing 0.22 Kilogram/m fixed on wall and beams including rounding of the edges with aluminium T of 50 mm x 40 mm weighing 0.39 Kilogram/m etc. including all labour etc. complete. First Floor
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 600mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete Ground Floor
Providing and laying chequered tiles of approved quality of size 30 cm x 30 cm, confirming to corresponding I.S. for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete Ground Floor
Providing and casting in situ or precast tapering R.C.C. M-20 Semi Barrier type Kerb without gutter ( as per IRC 86 1983) embedded 125mm below ground level over M-10 PCC finished neatly with C.M. 1:2, setting the same in C.M. 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batching and Mixing Plant Ground Floor
Providing and fixing European type wallhung white water closet of Paryware / Hindware with push valve concealed type with cover plate 32mm size of including soil pipe ,vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cutting& making good walls, floors etc. complete. GROUND FLOOR
Providing and fixing European type wallhung white water closet of Paryware / Hindware with push valve concealed type with cover plate 32mm size of including soil pipe ,vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cutting& making good walls, floors etc. complete. FIRST FLOOR
Providing and fixing European type wallhung white water closet of Paryware / Hindware with push valve concealed type with cover plate 32mm size of including soil pipe ,vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cutting& making good walls, floors etc. complete. SECOND FLOOR
Providing and fixing C.P.Two way BIB cock of approved make continental including necessary sockets/union nut etc. complete. GROUND FLOOR
Providing and fixing C.P.Two way BIB cock of approved make continental including necessary sockets/union nut etc. complete. FIRST FLOOR
Providing and fixing C.P.Two way BIB cock of approved make continental including necessary sockets/union nut etc. complete. SECOND FLOOR
Providing and fixing Shower Head, with shower arm of approved make mixer of all necessary pipe fittings and connections etc. complete as directed by Engineer in charge GROUND FLOOR
Providing and fixing Shower Head, with shower arm of approved make mixer of all necessary pipe fittings and connections etc. complete as directed by Engineer in charge FIRST FLOOR
Providing and fixing Shower Head, with shower arm of approved make mixer of all necessary pipe fittings and connections etc. complete as directed by Engineer in charge SECOND FLOOR
Providing and fixing Hand shower (health faucet) with 8mm dia. 1m long flexible tube having wall hook with approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. GROUND FLOOR
Providing and fixing Hand shower (health faucet) with 8mm dia. 1m long flexible tube having wall hook with approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. FIRST FLOOR
Providing and fixing Hand shower (health faucet) with 8mm dia. 1m long flexible tube having wall hook with approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. SECOND FLOOR
Providing and fixing Orissa Pan of size 580x445x260 mm with approved make flush valve including trap, C.I. soil and vent pipe upto outside face of wall including 100mm dia. C.I. plug, bend and necessary pipe connection, etc complete. As directed by Engineer in charge. GROUND FLOOR
Providing and fixing white glazed urinal of series with Pressmatic auto closing valve of having 32mm diameter P.V.C. flush pipe with fitting and flushing of approved make and arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc.complete as directed by Engineer in charge. GROUND FLOOR
Providing and fixing white glazed urinal of series with Pressmatic auto closing valve of having 32mm diameter P.V.C. flush pipe with fitting and flushing of approved make and arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc.complete as directed by Engineer in charge. FIRST FLOOR
Providing and fixing white glazed urinal of series with Pressmatic auto closing valve of having 32mm diameter P.V.C. flush pipe with fitting and flushing of approved make and arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc.complete as directed by Engineer in charge. SECOND FLOOR
Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. GROUND FLOOR
Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. FIRST FLOOR
Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. SECOND FLOOR
Providing and fixing Glass self 125 mm wide and 600 mm long with necessary chromium plated brackets providing T.W.gutties etc. complete GROUND FLOOR
Providing and fixing Glass self 125 mm wide and 600 mm long with necessary chromium plated brackets providing T.W.gutties etc. complete FIRST FLOOR
Providing and fixing Glass self 125 mm wide and 600 mm long with necessary chromium plated brackets providing T.W.gutties etc. complete SECOND FLOOR
Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. GROUND FLOOR
Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. FIRST FLOOR
Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. SECOND FLOOR
C.P.soap dish (polyurethane) GROUND FLOOR
C.P.soap dish (polyurethane) FIRST FLOOR
C.P.soap dish (polyurethane) SECOND FLOOR
Providing and fixing White glazed with bottle trap earthenware Wash Hand Basin of 55x40 cm size including cold water piller taps, brackets, rubber plugs and brass chain, stop tap, chromium plate bottle trap and necessary pipe connections including UPAC waste pipe and trap upto the outside face of the wall, making good the damaged surface, testing etc. complete. GROUND FLOOR
Providing and fixing White glazed with bottle trap earthenware Wash Hand Basin of 55x40 cm size including cold water piller taps, brackets, rubber plugs and brass chain, stop tap, chromium plate bottle trap and necessary pipe connections including UPAC waste pipe and trap upto the outside face of the wall, making good the damaged surface, testing etc. complete. FIRST FLOOR
Providing and fixing White glazed with bottle trap earthenware Wash Hand Basin of 55x40 cm size including cold water piller taps, brackets, rubber plugs and brass chain, stop tap, chromium plate bottle trap and necessary pipe connections including UPAC waste pipe and trap upto the outside face of the wall, making good the damaged surface, testing etc. complete. SECOND FLOOR
Providing and fixing Autoclosing pillar cock of pressmatic tap of approved make or equivalent including all fixtures, fittings etc. complete. GROUND FLOOR
Providing and fixing Autoclosing pillar cock of pressmatic tap of approved make or equivalent including all fixtures, fittings etc. complete. FIRST FLOOR
Providing and fixing Autoclosing pillar cock of pressmatic tap of approved make or equivalent including all fixtures, fittings etc. complete. SECOND FLOOR
Providingand fixing C.P.BIB cock with wall flange of approved makei ncluding necessary sockets/ union nut etc. complete. GROUND FLOOR
Providingand fixing C.P.BIB cock with wall flange of approved makei ncluding necessary sockets/ union nut etc. complete. FIRST FLOOR
Providingand fixing C.P.BIB cock with wall flange of approved makei ncluding necessary sockets/ union nut etc. complete. SECOND FLOOR
Providing and fixing C.P. sink cock with raised J" shaped swinging casted spout ofapprovedmake including necessary sockets/ union nut etc. complete." GROUND FLOOR
Providing and fixing C.P. sink cock with raised J" shaped swinging casted spout ofapprovedmake including necessary sockets/ union nut etc. complete." FIRST FLOOR
Providing and fixing C.P. sink cock with raised J" shaped swinging casted spout ofapprovedmake including necessary sockets/ union nut etc. complete." SECOND FLOOR
Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend,connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) GROUND FLOOR
Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend,connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) FIRST FLOOR
Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend,connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) SECOND FLOOR
Ball cock for 25mm dia. GROUND FLOOR
Ball cock for 25mm dia. FIRST FLOOR
Ball cock for 25mm dia. SECOND FLOOR
Providing and fixing Ball Cock for 32 mm including necessary sockets/union nut complete. GROUND FLOOR
Providing and fixing Ball Cock for 32 mm including necessary sockets/union nut complete. FIRST FLOOR
Providing and fixing Ball Cock for 32 mm including necessary sockets/union nut complete. SECOND FLOOR
Providing and fixing Ball Cock for 40 mm including necessary sockets/union nut complete. GROUND FLOOR
Providing and fixing Ball Cock for 40 mm including necessary sockets/union nut complete. FIRST FLOOR
Providing and fixing Ball Cock for 40 mm including necessary sockets/union nut complete. SECOND FLOOR
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. GROUND FLOOR
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. FIRST FLOOR
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. SECOND FLOOR
Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete GROUND FLOOR
Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete FIRST FLOOR
Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete SECOND FLOOR
Providing , laying and fixing P.V.C. pipe of 50 mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. GROUND FLOOR
Providing , laying and fixing P.V.C. pipe of 50 mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. FIRST FLOOR
Providing , laying and fixing P.V.C. pipe of 50 mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. SECOND FLOOR
Providing, laying and fixing P.V.C. pipe of 32mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. GROUND FLOOR
Providing, laying and fixing P.V.C. pipe of 32mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. FIRST FLOOR
Providing, laying and fixing P.V.C. pipe of 32mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. SECOND FLOOR
Providing, laying and fixing P.V.C. pipe of 40mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Includingremoving existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. GROUND FLOOR
Providing, laying and fixing P.V.C. pipe of 40mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Includingremoving existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. FIRST FLOOR
Providing, laying and fixing P.V.C. pipe of 40mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Includingremoving existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. SECOND FLOOR
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. GROUND FLOOR
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. FIRST FLOOR
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. SECOND FLOOR
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. GROUND FLOOR
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. FIRST FLOOR
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. SECOND FLOOR
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. GROUND FLOOR
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. FIRST FLOOR
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. SECOND FLOOR
Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. GROUND FLOOR
Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. FIRST FLOOR
Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. SECOND FLOOR
Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. GROUND FLOOR
Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. FIRST FLOOR
Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. SECOND FLOOR
Providing and fixing on walls/ ceiling/ floors, 50 mm dia heavy grade having embossed as ISI Mark galvanised iron pipes weight of 6.33 Kilogram/meter with necessary fittings.and remaking good the demolished portion and primer of anti corrossive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. GROUND FLOOR
Providing and fixing on walls/ ceiling/ floors, 50 mm dia heavy grade having embossed as ISI Mark galvanised iron pipes weight of 6.33 Kilogram/meter with necessary fittings.and remaking good the demolished portion and primer of anti corrossive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. FIRST FLOOR
Providing and fixing on walls/ ceiling/ floors, 50 mm dia heavy grade having embossed as ISI Mark galvanised iron pipes weight of 6.33 Kilogram/meter with necessary fittings.and remaking good the demolished portion and primer of anti corrossive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. SECOND FLOOR
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. GROUND FLOOR
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. FIRST FLOOR
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. SECOND FLOOR
Providing and fixing Ball Cock for 32 mm with necessary fittings. GROUND FLOOR
Providing and fixing Ball Cock for 32 mm with necessary fittings. FIRST FLOOR
Providing and fixing Ball Cock for 32 mm with necessary fittings. SECOND FLOOR
Providing and fixing Ball Valve for 50 mm with necessary fittings. GROUND FLOOR
Providing and fixing Ball Valve for 50 mm with necessary fittings. FIRST FLOOR
Providing and fixing Ball Valve for 50 mm with necessary fittings. SECOND FLOOR
Providing and fixing Ball Valve for 50 mm with necessary fittings. GROUND FLOOR
Providing and fixing Ball Valve for 50 mm with necessary fittings. FIRST FLOOR
Providing and fixing Ball Valve for 50 mm with necessary fittings. SECOND FLOOR
Providing and fixing C.P. Angular stop clock with wall flange of approved make continentalincluding necessary sockets/union nut etc. complete. GROUND FLOOR
Providing and fixing C.P. Angular stop clock with wall flange of approved make continentalincluding necessary sockets/union nut etc. complete. FIRST FLOOR
Providing and fixing C.P. Angular stop clock with wall flange of approved make continentalincluding necessary sockets/union nut etc. complete. SECOND FLOOR
Providing and fixing Strainer for 50 mm with necessary fittings. GROUND FLOOR
Providing and fixing Strainer for 50 mm with necessary fittings. FIRST FLOOR
Providing and fixing Strainer for 50 mm with necessary fittings. SECOND FLOOR
Providing and fixing 45 cm wide mild steel ladder of 40mm x 6 mm mild steel flat stringers and steps of 18 mm dia. mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60cm x 30cm x 30cm and painting the ladder complete. (Anti Corossive Paint) GROUND FLOOR
Providing and fixing 45 cm wide mild steel ladder of 40mm x 6 mm mild steel flat stringers and steps of 18 mm dia. mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60cm x 30cm x 30cm and painting the ladder complete. (Anti Corossive Paint) FIRST FLOOR
Providing and fixing 45 cm wide mild steel ladder of 40mm x 6 mm mild steel flat stringers and steps of 18 mm dia. mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60cm x 30cm x 30cm and painting the ladder complete. (Anti Corossive Paint) SECOND FLOOR
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. GROUND FLOOR
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. FIRST FLOOR
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. SECOND FLOOR
Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete GROUND FLOOR
Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete FIRST FLOOR
Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete SECOND FLOOR
Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. GROUND FLOOR
Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. FIRST FLOOR
Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. SECOND FLOOR
Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made outo flow density polythylerand built corrugation including of delivery upto destination hoisting and fixing of accessories such as inlet,outlet over flow of alltanks capacity above 1000 to 20,000 litres GROUND FLOOR
Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made outo flow density polythylerand built corrugation including of delivery upto destination hoisting and fixing of accessories such as inlet,outlet over flow of alltanks capacity above 1000 to 20,000 litres FIRST FLOOR
Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made outo flow density polythylerand built corrugation including of delivery upto destination hoisting and fixing of accessories such as inlet,outlet over flow of alltanks capacity above 1000 to 20,000 litres SECOND FLOOR
Providing and Fixing toilet set for differently Abled persons consist of Floor Mounted white vitreous china water Closet including 6 litre capacity white vitreous china flushing Cistern with raised soft-push button,white vitreous china wash basin of size 46x36 cm and one no SS304 hinge drail 76 cms & three no SS304 of (Grab Bar) 60 cm sall including cutting and making good the walls and floors wherever required, seat cover, cistern & washbasin fittings,nuts, bolts and gasket etc complete as per the direction of Engineer-In-charge. GROUND FLOOR
Providing & fixing 39 / 40 mm thick sandwiched type flush door shutter by using 18 mm thick x 2 commercial plywood of exterior grade as per detailed drawings with 1.50 mm thick approved laminated on both faces of shutter or as directed, all necessary bends, T.W. lipping & moldings, stainless steel fixtures & fastenings, with both side SS/ Hdrop for lock, stainless steel handles on both sides, finishing with melamine polish to four edges etc. complete. (Ply 18 x 2 =36mm + laminate 1.50 x 2 =3 mm = Total 39mm) Ground Floor
Providing & fixing 39 / 40 mm thick sandwiched type flush door shutter by using 18 mm thick x 2 commercial plywood of exterior grade as per detailed drawings with 1.50 mm thick approved laminated on both faces of shutter or as directed, all necessary bends, T.W. lipping & moldings, stainless steel fixtures & fastenings, with both side SS/ Hdrop for lock, stainless steel handles on both sides, finishing with melamine polish to four edges etc. complete. (Ply 18 x 2 =36mm + laminate 1.50 x 2 =3 mm = Total 39mm) First Floor
Providing and fixing sky light as per drawing including 10 mm thick multi wall poly carbonate sheet in Lexan of Sabic make of approved colour including 60mm x 60mm square tube,12 mm base plate,10 gauge weld mesh,25mm x 25mm x 5mm MS angle including coat. Ground Floor
Providing and fixing sky light as per drawing including 10 mm thick multi wall poly carbonate sheet in Lexan of Sabic make of approved colour including 60mm x 60mm square tube,12 mm base plate,10 gauge weld mesh,25mm x 25mm x 5mm MS angle including coat. First Floor
Providing and fixing sky light as per drawing including 10 mm thick multi wall poly carbonate sheet in Lexan of Sabic make of approved colour including 60mm x 60mm square tube,12 mm base plate,10 gauge weld mesh,25mm x 25mm x 5mm MS angle including coat. Second Floor
Providing and fixing machine cut polished 18 to 20mm thick telephone black/Amba white/Cat bary brown/RBI Card/Ocean brown granote stones for Treads & Riser of stair Steps/Enterance steps of approved colour and shade with double granite (Sandwitched Type) Full moulding/Nosing for the treads on bed of 1:4 cement mortar including float filling joints with neat cement slurry,Curing,Polishing,Polishing to full moulding,and cleaing etc.Complete Ground Floor
Providing and fixing machine cut polished 18 to 20mm thick telephone black/Amba white/Cat bary brown/RBI Card/Ocean brown granote stones for Treads & Riser of stair Steps/Enterance steps of approved colour and shade with double granite (Sandwitched Type) Full moulding/Nosing for the treads on bed of 1:4 cement mortar including float filling joints with neat cement slurry,Curing,Polishing,Polishing to full moulding,and cleaing etc.Complete First Floor
Providing and fixing machine cut polished 18 to 20mm thick telephone black/Amba white/Cat bary brown/RBI Card/Ocean brown granote stones for Treads & Riser of stair Steps/Enterance steps of approved colour and shade with double granite (Sandwitched Type) Full moulding/Nosing for the treads on bed of 1:4 cement mortar including float filling joints with neat cement slurry,Curing,Polishing,Polishing to full moulding,and cleaing etc.Complete Second Floor
Providing flaming treatment to granite slab to get desired rough and matt surface finish including cleaning washing etc. Ground Floor
Providing & Laying full body vitrified tile / slabs which are manufactured by using excusive technology continua+ ( Digital Day Decoration Digital system) having Size 3000 x 800 x 15 mm thick full body glossy/matt finish ( standard as per 13006:2018 EN 14411 Gr.Bla.for Glossiness 90% with nano technology except hydraulic acid & its Compound ), as per the finishes & designs using colored clay powder & clay flex throughout the body Including all material Transportation laying/fixing and Filling the joint's with colored Pigment's on the base of bed C.M. 1:3 as per Design Pattern / Details, cleaning washing etc. complete. ( simpolo or equivalent ) Ground Floor
Supplying, & fixing in position aluminium fins of 1000X50x25 mm with special locking system designed by Elegance architerural products supported by 38x38mm L-Angle with pre-punchated hole as per approved gap horizontal carriers both, having thickness of 1mm and a clear gap of 50mm between verical members as per pattern,choice of colour,finish, etc. as shown in approved drawing and as instructed by site Incharge. Rates shall be inclusive of supply & fixing using 1mm thick L-clit of dim. 50mm X 50mm X 50mm & SS-screws), application of powder coating, cutting, making, fixing, transportation, loading, unloading, lifting, shifting, saftey precautions etc. all complete. Ground Floor
Supplying, & fixing in position aluminium fins of 1000X50x25 mm with special locking system designed by Elegance architerural products supported by 38x38mm L-Angle with pre-punchated hole as per approved gap horizontal carriers both, having thickness of 1mm and a clear gap of 50mm between verical members as per pattern,choice of colour,finish, etc. as shown in approved drawing and as instructed by site Incharge. Rates shall be inclusive of supply & fixing using 1mm thick L-clit of dim. 50mm X 50mm X 50mm & SS-screws), application of powder coating, cutting, making, fixing, transportation, loading, unloading, lifting, shifting, saftey precautions etc. all complete. First Floor
Supplying, & fixing in position aluminium fins of 1000X50x25 mm with special locking system designed by Elegance architerural products supported by 38x38mm L-Angle with pre-punchated hole as per approved gap horizontal carriers both, having thickness of 1mm and a clear gap of 50mm between verical members as per pattern,choice of colour,finish, etc. as shown in approved drawing and as instructed by site Incharge. Rates shall be inclusive of supply & fixing using 1mm thick L-clit of dim. 50mm X 50mm X 50mm & SS-screws), application of powder coating, cutting, making, fixing, transportation, loading, unloading, lifting, shifting, saftey precautions etc. all complete. Second Floor
Providing Supplying, & fixing in position aluminium fins of 4000x150x100 mm with special locking system designed by Elegance architerural or Equivalent products supported by 50x50mm L-Angle with pre-punchated hole as per approved gap horizontal carriers both, having thickness of 1.2mm and a clear gap of 150mm between verical members as per pattern,choice of colour,finish, etc. as shown in approved drawing and as instructed by site Incharge. Rates shall be inclusive of supply & fixing using 1mm thick L-clit of dim. 50mm X 50mm X 50mm & SS-screws), application of powder coating, cutting, making, fixing, transportation, loading, unloading, lifting, shifting, saftey precautions etc. all complete. Ground Floor
Providing Supplying, & fixing in position aluminium fins of 4000x150x100 mm with special locking system designed by Elegance architerural or Equivalent products supported by 50x50mm L-Angle with pre-punchated hole as per approved gap horizontal carriers both, having thickness of 1.2mm and a clear gap of 150mm between verical members as per pattern,choice of colour,finish, etc. as shown in approved drawing and as instructed by site Incharge. Rates shall be inclusive of supply & fixing using 1mm thick L-clit of dim. 50mm X 50mm X 50mm & SS-screws), application of powder coating, cutting, making, fixing, transportation, loading, unloading, lifting, shifting, saftey precautions etc. all complete. First Floor
Providing Supplying, & fixing in position aluminium fins of 4000x150x100 mm with special locking system designed by Elegance architerural or Equivalent products supported by 50x50mm L-Angle with pre-punchated hole as per approved gap horizontal carriers both, having thickness of 1.2mm and a clear gap of 150mm between verical members as per pattern,choice of colour,finish, etc. as shown in approved drawing and as instructed by site Incharge. Rates shall be inclusive of supply & fixing using 1mm thick L-clit of dim. 50mm X 50mm X 50mm & SS-screws), application of powder coating, cutting, making, fixing, transportation, loading, unloading, lifting, shifting, saftey precautions etc. all complete. Second Floor
Providing and fixing horizontal level Armstrong Cellio Open cell GI lay-in ceiling tiles with border panels forming board edge of size 600x600x38mm (Nominal) having cell size of 150x150mm made of 120 gsm galvanized steel as per IS 277 (2003) suitable for architectural finishes in 0.35mm thickness as per in IS:513 (1994)in Global white color. The tile shall be electrostatically polyester powder coated using RoHS compliant powder having coating thickness ranging from 60-80 microns. The powder coating shall pass Salt Spray Test for 750 hours as per ASTM B117, QUV –A Test for 1000 hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000 hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E<1 using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ as per ASTM D523. Tile shall have a Fire Performance class A1 as per EN-13964.Properties of Tile Relevant Standards10-07-2021: Base MAterial 120 gsm Galvanised Steel IS 277 (2003 ) Galvanization Panel Dimensions 600x600x38mm(Nominal)/594x594x38mm (Actual) Panel Thickness 0.35 mm IS:513(1994) thickness, Cell Size 150x150mm, Panel Fiish Electrostatically polyster powder coated using RoHS Compliant powder having coating thickness ranging from 60-80 Microns. Salt Spray Tested for 750 hours/ QUV –A Test for 1000 hours/ Humidity test for 1000 hours . Adhesion of GT0 as per EN ISO 2409. The shade variation within a manufacture batche shall be delta E<1 using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ASTM B117(Salt Spray Test ) ASTM G-154 - (Cycle-1)(QUV-A test), DIN 50017 (Humidity Test ) EN ISO 2409 ( Adhesion ),ASTM D 523 (Gloss) Fire Property Class A1 EN-13964 . Ground Floor
Providing and fixing horizontal level Armstrong Cellio Open cell GI lay-in ceiling tiles with border panels forming board edge of size 600x600x38mm (Nominal) having cell size of 150x150mm made of 120 gsm galvanized steel as per IS 277 (2003) suitable for architectural finishes in 0.35mm thickness as per in IS:513 (1994)in Global white color. The tile shall be electrostatically polyester powder coated using RoHS compliant powder having coating thickness ranging from 60-80 microns. The powder coating shall pass Salt Spray Test for 750 hours as per ASTM B117, QUV –A Test for 1000 hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000 hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E<1 using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ as per ASTM D523. Tile shall have a Fire Performance class A1 as per EN-13964.Properties of Tile Relevant Standards10-07-2021: Base MAterial 120 gsm Galvanised Steel IS 277 (2003 ) Galvanization Panel Dimensions 600x600x38mm(Nominal)/594x594x38mm (Actual) Panel Thickness 0.35 mm IS:513(1994) thickness, Cell Size 150x150mm, Panel Fiish Electrostatically polyster powder coated using RoHS Compliant powder having coating thickness ranging from 60-80 Microns. Salt Spray Tested for 750 hours/ QUV –A Test for 1000 hours/ Humidity test for 1000 hours . Adhesion of GT0 as per EN ISO 2409. The shade variation within a manufacture batche shall be delta E<1 using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ASTM B117(Salt Spray Test ) ASTM G-154 - (Cycle-1)(QUV-A test), DIN 50017 (Humidity Test ) EN ISO 2409 ( Adhesion ),ASTM D 523 (Gloss) Fire Property Class A1 EN-13964 . First Floor
Providing and fixing horizontal level Armstrong Cellio Open cell GI lay-in ceiling tiles with border panels forming board edge of size 600x600x38mm (Nominal) having cell size of 150x150mm made of 120 gsm galvanized steel as per IS 277 (2003) suitable for architectural finishes in 0.35mm thickness as per in IS:513 (1994)in Global white color. The tile shall be electrostatically polyester powder coated using RoHS compliant powder having coating thickness ranging from 60-80 microns. The powder coating shall pass Salt Spray Test for 750 hours as per ASTM B117, QUV –A Test for 1000 hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000 hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E<1 using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ as per ASTM D523. Tile shall have a Fire Performance class A1 as per EN-13964.Properties of Tile Relevant Standards10-07-2021: Base MAterial 120 gsm Galvanised Steel IS 277 (2003 ) Galvanization Panel Dimensions 600x600x38mm(Nominal)/594x594x38mm (Actual) Panel Thickness 0.35 mm IS:513(1994) thickness, Cell Size 150x150mm, Panel Fiish Electrostatically polyster powder coated using RoHS Compliant powder having coating thickness ranging from 60-80 Microns. Salt Spray Tested for 750 hours/ QUV –A Test for 1000 hours/ Humidity test for 1000 hours . Adhesion of GT0 as per EN ISO 2409. The shade variation within a manufacture batche shall be delta E<1 using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ASTM B117(Salt Spray Test ) ASTM G-154 - (Cycle-1)(QUV-A test), DIN 50017 (Humidity Test ) EN ISO 2409 ( Adhesion ),ASTM D 523 (Gloss) Fire Property Class A1 EN-13964 . Second Floor
Providing and fixing aluminium system anodized sliding window of various sizes. Sliding will be made from Geeta / Blueshield 25 mm slim series or equivalent system. Windows will be of specially extruded aluminium 3 Track 2 Glass + 1 net shutter, track joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonary opening of windows with S.S 202 wood screws. Glass shutter will be made from specially extruded aluminium section , Glass considered is 5mm clear toughened glass. All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to form uniform hairline joints. All shutter will be fixed to main frame with neccessary double roller to have smooth and easy movement of shutter. shutters will have single point self pressing lock. All fixing screws will be of S.S 202. Windows will be sealed with weather sealant from outer periphery,etc.complete Ground Floor
Providing and fixing aluminium system anodized sliding window of various sizes. Sliding will be made from Geeta / Blueshield 25 mm slim series or equivalent system. Windows will be of specially extruded aluminium 3 Track 2 Glass + 1 net shutter, track joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonary opening of windows with S.S 202 wood screws. Glass shutter will be made from specially extruded aluminium section , Glass considered is 5mm clear toughened glass. All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to form uniform hairline joints. All shutter will be fixed to main frame with neccessary double roller to have smooth and easy movement of shutter. shutters will have single point self pressing lock. All fixing screws will be of S.S 202. Windows will be sealed with weather sealant from outer periphery,etc.complete First Floor
Providing and fixing aluminium system anodized sliding window of various sizes. Sliding will be made from Geeta / Blueshield 25 mm slim series or equivalent system. Windows will be of specially extruded aluminium 3 Track 2 Glass + 1 net shutter, track joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonary opening of windows with S.S 202 wood screws. Glass shutter will be made from specially extruded aluminium section , Glass considered is 5mm clear toughened glass. All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to form uniform hairline joints. All shutter will be fixed to main frame with neccessary double roller to have smooth and easy movement of shutter. shutters will have single point self pressing lock. All fixing screws will be of S.S 202. Windows will be sealed with weather sealant from outer periphery,etc.complete Second Floor
Providing and fixing aluminium system anodized fixed window of various sizes. Casement will be made from Geeta / Blueshield 40 mm series or equivalent System. Windows will be of specially extruded aluminium section, joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonry opening of windows with S S 202 wood screws. Fixed glass casement will be made from specially extruded aluminum section, glass considered is 5 mm clear toughened glass. All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to form uniform hairline joint. All fixing screws will be of S S 202. Windows will be sealed with weather sealant from outer periphery, etc. complete. Ground Floor
Providing and fixing aluminium system anodized fixed window of various sizes. Casement will be made from Geeta / Blueshield 40 mm series or equivalent System. Windows will be of specially extruded aluminium section, joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonry opening of windows with S S 202 wood screws. Fixed glass casement will be made from specially extruded aluminum section, glass considered is 5 mm clear toughened glass. All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to form uniform hairline joint. All fixing screws will be of S S 202. Windows will be sealed with weather sealant from outer periphery, etc. complete. First Floor
Providing and fixing aluminium system anodized fixed window of various sizes. Casement will be made from Geeta / Blueshield 40 mm series or equivalent System. Windows will be of specially extruded aluminium section, joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonry opening of windows with S S 202 wood screws. Fixed glass casement will be made from specially extruded aluminum section, glass considered is 5 mm clear toughened glass. All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to form uniform hairline joint. All fixing screws will be of S S 202. Windows will be sealed with weather sealant from outer periphery, etc. complete. Second Floor
Providing and fixing in position Anodised aluminium system louvered windows / ventilator of various sizes with anodising as per detailed drawing and specifications including aluminium frames made from Geeta / Kapil louvers or equivalent system. Glass considered is 5mm thick Bajiri/ frosted sheet glass louvers, of aprroved quality etc. Complete. Ground Floor
Providing and fixing in position Anodised aluminium system louvered windows / ventilator of various sizes with anodising as per detailed drawing and specifications including aluminium frames made from Geeta / Kapil louvers or equivalent system. Glass considered is 5mm thick Bajiri/ frosted sheet glass louvers, of aprroved quality etc. Complete. First Floor
Providing And Fixing 40mm thick Sandwitched type Roofing Sheet/ Pannel Comprising of 0.40 mm Thick Precolour Coated Galvalume Sheet Top & Bottom , And Sandwitched by 39 mm Thick Riqid Puf having 35/40 kg/sqm in profiled form including fixing on purlin by zinic coated self drilling 100 mm long screws , Cutting sheets as per requirements, laying & fixing with Lapping as per detailed drawing & design, Cleaning, neccessary scafolding, including providing & fixing necessary Ridges, etc.Complete. (Brand/ Make- JSW,TATA or Equivalent ) Ground Floor
Providing & fixing Fabricated Tubular steel grilled openable gate supported by 219.10 mm dia. M.S. pipe columns, fabricated by using steel pipes, m.s. flat , m.s. plate as per detailed drawing including extra heavy fabricated hinges, locking arrangement, all necessary including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete Ground Floor
Providing and fixing M.S.Pipe railing consisting of hand rail 60.30mm outer diameter confirming 3.60kg/m vertically supported by 25x5 M.S.Flats at & having base 25x5mm M.S.Flat on constructed RCC Pardi/BB Wall as per detailed drawing & design including fabrication,Cutting, Welding,Grinding,& Fixing with one coat of primer & two coats of synthetic enamel paint of approved shade etc.Complete For Rate Analysis Consider length 3.00m Ground Floor
Providing and fixing M.S.Pipe railing consisting of hand rail 60.30mm outer diameter confirming 3.60kg/m vertically supported by 25x5 M.S.Flats at & having base 25x5mm M.S.Flat on constructed RCC Pardi/BB Wall as per detailed drawing & design including fabrication,Cutting, Welding,Grinding,& Fixing with one coat of primer & two coats of synthetic enamel paint of approved shade etc.Complete For Rate Analysis Consider length 3.00m First Floor
Providing and fixing M.S.Pipe railing consisting of hand rail 60.30mm outer diameter confirming 3.60kg/m vertically supported by 25x5 M.S.Flats at & having base 25x5mm M.S.Flat on constructed RCC Pardi/BB Wall as per detailed drawing & design including fabrication,Cutting, Welding,Grinding,& Fixing with one coat of primer & two coats of synthetic enamel paint of approved shade etc.Complete For Rate Analysis Consider length 3.00m Second Floor
Providing & Fixing powder coated G.I. with Glazed openable door shutters (French door type) with frame consisting of 125x60mm G I Box type frame by using 18 gauge G.I.sheet including all necessary hold fasts etc, and openable ( folding /french type ) 22 gauge G.I.Section pressed in various profiles (Z,T etc.) , including providing 10mm Sq.gaurd bars and 5 mm thick plain glass, standard stainless steel fittings (aldrop,tower bolt,hinges , etc.) inclusive all Lobour,material,Transportation ,fixing on site with attractive powder coating finish to GI section etc. Complete Ground Floor
Providing & Fixing powder coated G.I. with Glazed openable door shutters (French door type) with frame consisting of 125x60mm G I Box type frame by using 18 gauge G.I.sheet including all necessary hold fasts etc, and openable ( folding /french type ) 22 gauge G.I.Section pressed in various profiles (Z,T etc.) , including providing 10mm Sq.gaurd bars and 5 mm thick plain glass, standard stainless steel fittings (aldrop,tower bolt,hinges , etc.) inclusive all Lobour,material,Transportation ,fixing on site with attractive powder coating finish to GI section etc. Complete First Floor
Providing & Fixing powder coated G.I. with Glazed openable door shutters (French door type) with frame consisting of 125x60mm G I Box type frame by using 18 gauge G.I.sheet including all necessary hold fasts etc, and openable ( folding /french type ) 22 gauge G.I.Section pressed in various profiles (Z,T etc.) , including providing 10mm Sq.gaurd bars and 5 mm thick plain glass, standard stainless steel fittings (aldrop,tower bolt,hinges , etc.) inclusive all Lobour,material,Transportation ,fixing on site with attractive powder coating finish to GI section etc. Complete Second Floor
Providing and fixing Aluminium colour Anodised Sliding Folding Door 3+1 Shutters having Special patented Frame & shutter profiles. Outer frame Profiles being fixed to the missionary with SS-202 Screws & shutters having 45 degree corner joints with special cleats for linear joints having 6mm toughened glass are installed in the frame structure with Mortise Lock at Opening , Top & Bottom pivots for sliding, but hinges for folding operation & subsidiary multi point locking & pop handle for additional security, Complete. Ground Floor
STRETCH CEILING-Providing and fixing of calendered vinyl fabric along with patented alluminium profile .GOQ samsung LED to be used along with meanwell drivers,neccessary hardware and accessories Stretch light box ceiling with Euroceil Stretch Fabric Ceiling Light Plane White with proper 18 mm plywood thick for perimeter and 4mm thick of plywood on the celing for LED with all fitting & material including scaffolding if necessary as per detailed drawings and three coats of spray painting to boards.make -Euroceil. Ground Floor
Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 x 9 x 3 mm minimum size, crossings of M.S. flats of size 18 x 5 mm T or E section for runner of minimum 40 x 6 mm size for flange, M.S. flat for top runner of minimum size 40 x 12 mm with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 mm max. spacing of vertical channels be 100 mm enclosed gate position and clear space of 150 mm between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer and oil painting etc. complete. (I.S. 105211983) Ground Floor
Boom Barrier - Providing, supplying, installation & commissioning imported type or equivalent make boom barrier at entrance gate having clear opening width 3.50 m to 4.50 m including LED lighting system with variable flashing, three station push button fixed support, pair of photocells with anodized aluminum vertical mounting etc. also boom barrier comprising of white spray-painted aluminum boom with end cap & passive rubber safety edges and fixed support. Rabust spring balanced gear system, encoder-controlled movement, external manual release system with key operation including packaging charges, transportation, transit insurance, loading / unloading, installation on site, commissioning, warranty for automation system against manufacturing defect for a period of 12 months from the date of installation etc. complete. (excluding GST) Ground Floor
Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish Ground Floor
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. Ground Floor
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. First Floor
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. Second Floor
Kessel Grease Trap of 550 to 950 mm depth- NS 1, weight 111 Kg with Cover Class - 93 001/80 B in accordance with EN 1825 and DIN 4040-100, made of polyethylene. Ground Floor
Providing and fixing in position - aluminium fixed window fully glazed of any size as per detailed drawing and as directed by Engineerincharge with all necessary alluminium sections including necessary fixtures and fastening such as 5 mm thick clear float glass etc. complete.a) Colour anodized Ground Floor
Providing and fixing in position - aluminium fixed window fully glazed of any size as per detailed drawing and as directed by Engineerincharge with all necessary alluminium sections including necessary fixtures and fastening such as 5 mm thick clear float glass etc. complete.a) Colour anodized First Floor
Providing and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles of size 15mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 20mm , suitable for Green Building application, with Recycled content of 32%. The tile shall be laid on precoated G.I.channel on XL2 Clip having a web height of 32 mm with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm and 600 mm Cross Tees with a web height of 32 mm and a load carrying capacity of 7.7 Kilograms /M2 and minimum pull out strength of 100 Kilograms.. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system. The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete. Ground Floor
ACOUSTICAL WALL PANELLING – FABRIC WRAPPED OF SIZE: 600X600/1200X25MM Providing and Fixing of Acoustical Wall Panel with square edges made of fibre glass substrate 25mm thick, wrapped on the front side with an acoustically transparent fabric as per the approved shade (Husk, Copper, Sangria, Sesame, Coffee, Charcoal, Titanium, Flame, Peanut and Shell). The panel shall be classified for Fire Class A, as per ASTM E-84. The Acoustical Wall Panel shall be of sizes 600x600mm (Nominal) or 600x1200mm (Nominal) and shall achieve an NRC of 0.85 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) with 50mm airgap as per ASTM C423 to be fixed to wall on a framework of wooden battens and using Wall panel Impalers (supplied by the manufacturer) or by using construction adhesives (as per the instructions laid down by the manufacturer). The fibre glass substrate shall have a recycle content of 85%. Installation:An appropriate vapour barrier (by others) shall be applied/installed on the vertical surface before the installation to properly seal against entry of any moisture. Vapour barrier (by others) shall be installed as per Manufacturer’s recommendation. Install wooden batten grid (provided by others) of section 50x50mm or as approved by the Architect on the solid wall/partition to provide level and plumb surface. The Impalers shall be fixed to the battens using self-tapping screws, 3 nos. in case of 600x600mm and 4 nos. in case of 600x1200mm. Silica based construction adhesive (by others) to be dabbed on to the projecting elements. Ground Floor
Providing and laying in situ cement concrete M20 with tremix treatment for 100 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc. complete. Ground Floor
Ball cock 25mm dia.P.V.C.FLOAT Ground Floor
Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works. Second Floor
Providing coursed rubble masonry first sort of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in superstructure including racking out joints on the inside when plastering is to be done, watering and scaffolding etc. complete. Ground Floor
Providing and constructing masonry in precast solid Concrete Block (Grade D-50 As per I.S. 2185, Part-I, 1974, Reframed 1987) having compressive strength 5-00 N/mm2) of size (300 mm x 200 mm x 150mm) in cement mortar 1:6 for superstructure including striking joints on unexposed faces, racking out joints on exposed faces, watering, curing and scaffolding etc. complete. Ground Floor
Providing dry/ trap/ granite/ quartzite / gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete
Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 mm depth, filling the joints with 6 mm size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete ) Ground Floor
Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete) Ground Floor
Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete.
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete Ground Floor
Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 Square Metre /Kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete. Ground Floor
Providing & Laying full body vitrified tile / slabs which are manufactured by using excusive technology continua+ ( Digital Day Decoration Digital system) having Size 3000 x 800 x 15 mm thick full body glossy finish ( standard as per 13006:2018 EN 14411 Gr.Bla.for Glossiness 90% with nano technology except hydraulic acid & its Compound ), as per the finishes & designs using colored clay powder & clay flex throughout the body Including all material Transportation laying/fixing and Filling the joint's with colored Pigment's on the base of bed C.M. 1:3 as per Design Pattern / Details, cleaning washing etc. complete. ( simpolo or equivalent ) Ground Floor
Providing & Laying full body vitrified tile / slabs which are manufactured by using excusive technology continua+ ( Digital Day Decoration Digital system) having Size 3000 x 800 x 15 mm thick full body glossy finish ( standard as per 13006:2018 EN 14411 Gr.Bla.for Glossiness 90% with nano technology except hydraulic acid & its Compound ), as per the finishes & designs using colored clay powder & clay flex throughout the body Including all material Transportation laying/fixing and Filling the joint's with colored Pigment's on the base of bed C.M. 1:3 as per Design Pattern / Details, cleaning washing etc. complete. ( simpolo or equivalent ) First Floor
Fire Door 45mm 1HR FRL (60/60) 3 Criteria - INTEGRITY / INSULATION/ STABILITY WOODEN DOOR - Fire Door Tested in accordance to IS: 3614 Part 2 Providing 60 min Fire rated doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 at National Test House, Govt of India laborator and/or with Central Building Research Institute, Govt of India undertaking with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology ("Non Combustible by Nature"). with prior approval of concerned Superitending Engineer. a) Door Frame: Supplying frames for Fire resistant door shutters 1st class Malaysian Hardwood Frame densified (810 Kilogram/cum) and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 psi pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 of section 120 X 60 mm spray quoted with 2 coats of intumescent paint of minimum 200 micron, with single row of Brush- Type ASTROFLAME intumescent strip of size 10mm x 4mm affixed in the slit of the Frame for fire and smoke sealing, etc. complete. Ground Floor
b)Shutter : Providing of 65mm thick asbestos free composite - 3 criteria - fire, heat and smoke check Accoustic Door Shutter with flame guard of 120 minutes IS3614 part -II comprising of 2x9mm Calcium Silicate boards, Chemical treated internal timber with Fire retardant chemicals in pressure impregnation vessels under 160 PSI pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 frame work of 100x32 mm with 32mm thick infill of ceramic fiber (density 128Kilograms/CMT), vermaculite mix faced with 6mm Fire retardant High Density ply, internally lipped with hardwood beading, and pasted in Hydraulic Press under 50 tonnes pressure, spray quoted with 2 coats of In tumescent paint of minimum 200 micron, and with 1 row of Brush- Type Astroflame® intumescent strip (imported) of size 10mmx4mm concealed for fire and smoke sealing in the grooves in the shutter on all edges except bottom, without any external lipping.-Ground Floor
Supplying of FRP / GRP / COMPOSITE resin manhole cover and frame of appropriate size and load capacity of approved brand "THERMODRAIN" confirming to BSEN – 124:1994. Product shall have top abrasion resistant layer of decorative grey granite finish. It shall also confirm “Permanent Set” criterion as per BSEN-124. Product should be tested in test lab for load capacity and permanent set. The lifting arrangement should have an insert of 5mm in Glass Filled nylon socket type with key hole.-Circular Solid Top Manhole Cover with Frame - Ø500 mm - 2.5 Ton Load
Supplying of FRP / GRP / COMPOSITE resin manhole cover and frame of appropriate size and load capacity of approved brand "THERMODRAIN" confirming to BSEN – 124:1994. Product shall have top abrasion resistant layer of decorative grey granite finish. It shall also confirm “Permanent Set” criterion as per BSEN-124. Product should be tested in test lab for load capacity and permanent set. The lifting arrangement should have an insert of 5mm in Glass Filled nylon socket type with key hole.-Circular Solid Top Manhole Cover with Frame - Ø600 mm - 2.5 Ton Load
Supplying of FRP / GRP / COMPOSITE resin manhole cover and frame of appropriate size and load capacity of approved brand "THERMODRAIN" confirming to BSEN – 124:1994. Product shall have top abrasion resistant layer of decorative grey granite finish. It shall also confirm “Permanent Set” criterion as per BSEN-124. Product should be tested in test lab for load capacity and permanent set. The lifting arrangement should have an insert of 5mm in Glass Filled nylon socket type with key hole.-Circular Solid Top Manhole Cover with Frame - Ø600 mm - 5 Ton Load
Supplying of FRP / GRP / COMPOSITE resin manhole cover and frame of appropriate size and load capacity of approved brand "THERMODRAIN" confirming to BSEN – 124:1994. Product shall have top abrasion resistant layer of decorative grey granite finish. It shall also confirm “Permanent Set” criterion as per BSEN-124. Product should be tested in test lab for load capacity and permanent set. The lifting arrangement should have an insert of 5mm in Glass Filled nylon socket type with key hole.-D Square Solid Top Manhole Cover with Frame - 750 x 750 mm - 2.5 Ton Load
Providing and laying in trenches 25mm dai. CPVC pipe including necessary excavation, fittings. Refillingtrenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. GROUND FLOOR
Providing and laying in trenches 32mm dai. CPVC pipe including necessary excavation, fittings. Refillingtrenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.GROUND FLOOR
Providing and laying in trenches 40mm dai. CPVC pipe including necessary excavation, fittings. Refillingtrenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.-GROUND FLOOR
Providing and laying in trenches 50mm dai. CPVC pipe including necessary excavation, fittings. Refillingtrenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.-GROUND FLOOR
Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint /compression fitting joint or flang ed joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete. a) 63 mm HDPE (PE-100 a) 6 Kg/Sq. cm ::-GROUND FLOOR
Lowering, Laying and Jointing H. D. P. E./M D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II a) 63 mm HDPE (PE-100 a) 10 Kg/Sq. cm ::-GROUND FLOOR
Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour,operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position.. a) 63 mm HDPE (PE-100 a) 6 Kg/Sq. cm :-GROUND FLOOR
Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint /compression fitting joint or flang ed joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete. a) 100 mm HDPE (PE-100 a)6 Kg/Sq. cm ::-GROUND FLOOR
Lowering, Laying and Jointing H. D. P. E./M D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II a) 100 mm HDPE (PE-100 a) 10 Kg/Sq. cm :-GROUND FLOOR
Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position.. a) 100 mm HDPE (PE-100 a) 6 Kg/Sq. cm : :GROUND FLOOR
Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint /compression fitting joint or flang ed joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete. a) 160 mm HDPE (PE-100 a) 6 Kg/Sq. cm ::-GROUND FLOOR
Lowering, Laying and Jointing H. D. P. E./M D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II a) 160 mm HDPE (PE-100 a) 10 Kg/Sq. cm :-GROUND FLOOR
Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position.. a) 160 mm HDPE (PE-100 a) 6 Kg/Sq. cm :-GROUND FLOOR
Providing and fixing 25 mm diameter water meter with non-return valve including strainer, sockets/union nutand including water meter box making locking arrangement and lock.[Without chamber].GROUND FLOOR
Providing and fixing 40 mm diameter water meter with non-return valve including strainer, sockets/union nutand including water meter box making locking arrangement and lock.[Without chamber].-GROUND FLOOR
Providing and fixing 80 mm diameter water meter with non-return valve including strainer, sockets/union nutand including water meter box making locking arrangement and lock.[Without chamber].-GROUND FLOOR
Providing , constructing and fixing 600 mm dia. Inspection chamber made up of Polypropylene / polyethylene material Having 315 mm diameter inlet(s)/outlets and with eccentric reducers as per requirement to connect 160 mm and 200 mm pipes having thickness of 5 mm and 600 mm in height, with inbuilt shaft achieve the invert depth as per site condition of wall thickness of 5 mm having R.C.C. cover and frame fixing in 150 mm thick in c.c.1:2:4, having crushed sand bed of 150 mm thick of size 750 mm dia. Including excavation and refilling the sides of chamber by ?sand crushed cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc.complete.-GROUND FLOOR
Providing and fixing 15cm x 10cm salt glazed PVC gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.-GROUND FLOOR
Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester. Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67% Water absorption (as per ASTM):-0.30% Flammability as per ASTM Tensile strength:-115 MPA Specific Gravity at 25 degree centigrade 1.45 Izod impact strength:-65KJ/M2 Heat defection/distort temperature:-65deg C Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid PVC: -100mm Outlet pipe size rigid PVC:-80mm Gas outlet rigid PVC with Valve: 20mm Bacteria immobilization PVC mattes (on all partition) With DRDO TOT licensee and latest batch certificate(month & year of supply) and capacity as below- a) Up to 10 user size (1.0mx1.0mx0.70m), Capacity of biodgester:-700 liters, Area of top, bottom and side walls: - 4.80 sq.m, Area of partition walls: 1.40sq.m, Total weight of FRP: - 33.48 Kilogram, Bacteria inoculums quantity: - 200 liters , Minimum thickness of side walls / top and bottom: 3mm, Number of inside partitions: - 3, Minimum thickness of partition wall: 3mm.- GROUND FLOOR
h) Up to 150 user size (3.2mx2.0mx1.25m), Capacity of Biodigester:-8000 liters, Area of top, bottom and side walls: - 25.80 sq.m, Area of partition walls: 10.00sq.m, Total weight of FRP: - 397.08 Kilogram, Bacteria inoculums quantity: - 3200 liters, Minimum thickness of side walls / top and bottom: 7mm, Number of inside partitions: - 4, Minimum thickness of partition wall: 4mm- GROUND FLOOR
Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester. Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67% Water absorption (as per ASTM):-0.30% Flammability as per ASTM Tensile strength:-115 MPA Specific Gravity at 25 degree centigrade 1.45 Izod impact strength:-65KJ/M2 Heat defection/distort temperature:-65deg C Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid PVC: -100mm Outlet pipe size rigid PVC:-80mm Gas outlet rigid PVC with Valve: 20mm Bacteria immobilization PVC mattes (on all partition) With DRDO TOT licensee and latest batch certificate(month & year of supply) and capacity as below-c) Up to 25 user size (1.5mx1.0mx1.0m), Capacity of biodgester:-1500 liters, Area of top, bottom and side walls:- 8 sq.m, Area of partition walls: 2 sq.m, Total weight of frp: - 82.80 Kilogram, Bacteria inoculums quantity: - 600 liters, Minimum thickness of side walls / top and bottom: 5mm, Number of inside partitions: - 3, Minimum thickness of partition wall: 3mm- GROUND FLOOR
Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester. Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67% Water absorption (as per ASTM):-0.30% Flammability as per ASTM Tensile strength:-115 MPA Specific Gravity at 25 degree centigrade 1.45 Izod impact strength:-65KJ/M2 Heat defection/distort temperature:-65deg C Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid PVC: -100mm Outlet pipe size rigid PVC:-80mm Gas outlet rigid PVC with Valve: 20mm Bacteria immobilization PVC mattes (on all partition) With DRDO TOT licensee and latest batch certificate(month & year of supply) and capacity as below-g) Up to 100 user size (2.5mx2mx1m), Capacity of Biodigester:-5000 liters, Area of top, bottom and side walls: - 19.00 sq.m, Area of partition walls: 8.00sq.m, Total weight of FRP: - 248.40 Kilogram, Bacteria inoculums quantity: - 1800 liters, Minimum thickness of side walls / top and bottom: 6mm, Number of inside partitions: - 4, Minimum thickness of partition wall: 3mm - GROUND FLOOR
Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester. Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67% Water absorption (as per ASTM):-0.30% Flammability as per ASTM Tensile strength:-115 MPA Specific Gravity at 25 degree centigrade 1.45 Izod impact strength:-65KJ/M2 Heat defection/distort temperature:-65deg C Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid PVC: -100mm Outlet pipe size rigid PVC:-80mm Gas outlet rigid PVC with Valve: 20mm Bacteria immobilization PVC mattes (on all partition) With DRDO TOT licensee and latest batch certificate(month & year of supply) and capacity as below-i) Up to 200 user size (4mx2.0mx1.25m), Capacity of Biodigester:-10000 liters, Area of top, bottom and side walls: - 31.00 sq.m, Area of partition walls: 10.00sq.m, Total weight of FRP: - 462.60 Kilogram, Bacteria inoculums quantity: - 3400 liters, Minimum thickness of side walls / top and bottom: 7mm, Number of inside partitions: - 4, Minimum thickness of partition wall: 4mm- GROUND FLOOR
Providing soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick-bats.-GROUND FLOOR
Providing , constructing and fixing 450 mm dia. Inspection chamber made up of Polypropylene / polyethylene material of thickness 3.5 mm and height of 388 mm with 160 or 200 mm main inlet (s) outlet and 110 and / or 160 mm branch inlets, with 450 mm dia. Ultra shaft pipe of HDPE material having height of 460 mm, having R.C.C. cover and frame fixing in 150 mm thick in c.c.1:2:4, having crushed sand bed of 150 mm thick of size 750 mm dia. Including excavation and refilling the sides of chamber by sand crushed cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc. complete. -GROUND FLOOR
Supplying, Installing, Testing & Commissioning of Sewage Treatment Plant including Electro Mechanical work and execution of all civil work of Capacity 200 M3/Day (SIBF/Geen Belt Techanology) including Site Installation, pre-commissioning & Commissioning Supervision -GROUND FLOOR
Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete.-GROUND FLOOR
RWH - Recharge Pit Providing and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5" dia x 25m deep borewell at the floor of recharge pit including installation of combination of solid/perforated PVC casing pipe wrapped around with netlon mesh including 300mm thick sidefilling around outside of RCC rings (annular space) with 40mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC end-caps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge.-GROUND FLOOR
FURNITURE WORK-RECEPTION TABLE:-Providing and fixing in position customised "Reception Counter" having size 3.2 x 0 .6 x 0.75 meter made to measurement as per design drawing. Carcass shall be made out of 18mm commercial plywood conforming IS 303:1989, All exposed edges to be finished with best quality teakwood patti of size 1/2 inch. All inner surfaces to be finished with white laminate lining. & veneer used for outer faces , Top 1.8 X 0.450 meter & Frount 1.8 x 1.2 meter finish with 6 mm thick white corien used & Adhesives used shall be low-VOC compliant as per GRIHA.Including handles 150mm, Iron hinges, slidding strip channels, magnetic ball catcher, concealed lock, nails & screw and installation shall be in true line & level complete with necessary provision for electrical switches & wiring if any. The rate shall be inclusive of all labour, material, scaffolding, transportation, including all leads, lifts at all levels and as directed by Engineer Incharge.GROUND FLOOR
S.P.TABLE :Providing and fixing in position customised " S P Table having size 3.45 X 0.90 X 0.750 meter " & Side Table 1.4 X 0.6 X 0.6 meter made to measurement as per design drawing. Carcass shall be made out of 18 mm commercial plywood Conforming IS 303:1989 on surface, All exposed edges to be finished with best quality teakwood patti of size 1/2 inch. All Inner surfaces to be finished with 1 mm thick white laminate lining &Veneer 3.5 to 4 mm thick for outer faces and 6 mm thick white corien used on top side. Adhesives used shall be low-VOC compliant as per GRIHA.Including handles 150mm, Iron hinges, slidding strip channels, magnetic ball catcher, concealed lock, nails & screw and installation shall be in true line & level complete with necessary provision for electrical switches & wiring if any. The rate shall be inclusive of all labour, material, scaffolding, transportation, including all leads, lifts at all levels and as directed by Engineer Incharge. -FIRST FLOOR
CONFERANCE MEETING TABLE- Providing and fixing in position customised " Conference Table having size 8.0 X 2.10 X 0.750 meter "as per detail drawing with 18 mm thick commercial plywood Conforming IS 303:1989 on surface,all the edges to be finished with best quality teakwood bidding patti of size 1/2 inch. All inner surfaces to be finished with 1 mm thick white mica laminate & Veneer 3.5 to 4 mm thick for outer faces and total top finish with 6 mm thick white corien used. as per drawing .Adhesives used shall be low-VOC compliant. Including applying mealamine polish to all wood work, including Including , nails & screw and installation in true line & level complete with necessary provision for electrical switches & wiring if any.Including all leads, lifts at all levels etc. complete and as directed by Engineer Incharge..-FIRST FLOOR
DOUBLE BED-Providing and fixing in position Double bed of size 1.980 X 1.800 X 0.615 meter 'size in the Room with storage, wooden structure and wall paneling as per detail drawing with 18 mm thick commercial plywood Conforming IS 303:1989 on surface,all the edges to be finished with best quality teakwood bidding patti of size 1/2 inch. All inner surfaces to be finished with 1 mm thick white mica laminate & Veneer 3.5 to 4 mm thick for outer faces as per drawing . Adhesives used shall be low-VOC compliant. Including applying mealamine polish to all wood work, including handles 150mm, Iron hinges, nails & screw and installation shall be in true line & level complete with necessary provision for electrical switches & wiring if any.Including all leads, lifts at all levels etc. complete and as directed by Engineer Incharge. -GROUND FLOOR
DOUBLE BED-Providing and fixing in position Double bed of size 1.980 X 1.800 X 0.615 meter 'size in the Room with storage, wooden structure and wall paneling as per detail drawing with 18 mm thick commercial plywood Conforming IS 303:1989 on surface,all the edges to be finished with best quality teakwood bidding patti of size 1/2 inch. All inner surfaces to be finished with 1 mm thick white mica laminate & Veneer 3.5 to 4 mm thick for outer faces as per drawing . Adhesives used shall be low-VOC compliant. Including applying mealamine polish to all wood work, including handles 150mm, Iron hinges, nails & screw and installation shall be in true line & level complete with necessary provision for electrical switches & wiring if any.Including all leads, lifts at all levels etc. complete and as directed by Engineer Incharge.-FIRST FLOOR
WALDROBE WITH LUGGAGE STORAGE & SURVICE TABLE UNIT -1.50 X 0.600 X1.965 M WALDROBE, 1.20 X 0.600 X 0.415 M LUGGAGE STORAGE, 1.620 X 0.600 X 0.750 M SURVICE TABLE.Providing and fixing in position WALDROBE size 1.20 X 2.40 X 0.60 meter in the Room, wooden structure as per detail drawing with 18 mm thick commercial plywood Conforming IS 303:1989 on surface,all the edges to be finished with best quality teakwood bidding patti of size 1/2 inch. All surfaces to be finished with 1 mm thick white mica laminate as per drawing . Adhesives used shall be low-VOC compliant. Including applying mealamine polish to all wood work, Including handles 150mm, Iron hinges, slidding strip channels, magnetic ball catcher, concealed lock, nails & screw and installation shall be in true line & level complete with necessary provision for electrical switches & wiring if any.Including all leads, lifts at all levels etc. complete and as directed by Engineer Incharge.-GROUND FLOOR
WALDROBE WITH LUGGAGE STORAGE & SURVICE TABLE UNIT -1.50 X 0.600 X1.965 M WALDROBE, 1.20 X 0.600 X 0.415 M LUGGAGE STORAGE, 1.620 X 0.600 X 0.750 M SURVICE TABLE.Providing and fixing in position WALDROBE size 1.20 X 2.40 X 0.60 meter in the Room, wooden structure as per detail drawing with 18 mm thick commercial plywood Conforming IS 303:1989 on surface,all the edges to be finished with best quality teakwood bidding patti of size 1/2 inch. All surfaces to be finished with 1 mm thick white mica laminate as per drawing . Adhesives used shall be low-VOC compliant. Including applying mealamine polish to all wood work, Including handles 150mm, Iron hinges, slidding strip channels, magnetic ball catcher, concealed lock, nails & screw and installation shall be in true line & level complete with necessary provision for electrical switches & wiring if any.Including all leads, lifts at all levels etc. complete and as directed by Engineer Incharge FIRST FLOOR
TV CABINET WITH STUDY TABLE-Providing and fixing in position TV CABINET WITH STUDY TABLE size (1.82 X 0.6 X 0.75 meter)( 1.5 X 0.6X 0.750 meter ) in the Room, wooden structure as per detail drawing with 18 mm thick commercial plywood Conforming IS 303:1989 on surface Also granite top on luggage & survice table ,all the edges to be finished with best quality teakwood bidding patti of size 1/2 inch. All surfaces to be finished with Telephone Black Granite as per drawing . Adhesives used shall be low-VOC compliant. Including applying mealamine polish to all wood work, Including handles 150mm, Iron hinges, slidding strip channels, magnetic ball catcher, concealed lock, nails & screw and installation shall be in true line & level complete with necessary provision for electrical switches & wiring if any.Including all leads, lifts at all levels etc. complete and as directed by Engineer Incharge.GROUND FLOOR
TV CABINET WITH STUDY TABLE-Providing and fixing in position TV CABINET WITH STUDY TABLE size (1.82 X 0.6 X 0.75 meter)( 1.5 X 0.6X 0.750 meter ) in the Room, wooden structure as per detail drawing with 18 mm thick commercial plywood Conforming IS 303:1989 on surface Also granite top on luggage & survice table ,all the edges to be finished with best quality teakwood bidding patti of size 1/2 inch. All surfaces to be finished with Telephone Black Granite as per drawing . Adhesives used shall be low-VOC compliant. Including applying mealamine polish to all wood work, Including handles 150mm, Iron hinges, slidding strip channels, magnetic ball catcher, concealed lock, nails & screw and installation shall be in true line & level complete with necessary provision for electrical switches & wiring if any.Including all leads, lifts at all levels etc. complete and as directed by Engineer Incharge -FIRST FLOOR
DINNING TABLE -Providing and fixing in position U SHAPE DINNING TABLE 5.95 X 3.00 meter size in the Room, wooden structure as per detail drawing with 18 mm thick commercial plywood Conforming IS 303:1989 on surface Also granite top on luggage & survice table ,all the edges to be finished with best quality teakwood bidding patti of size 1/2 inch. All surfaces to be finished with Telephone Black Granite as per drawing . Adhesives used shall be low-VOC compliant. Including applying mealamine polish to all wood work, Including concealed lock, nails & screw and installation shall be in true line & level complete with necessary provision for electrical switches & wiring if any.Including all leads, lifts at all levels etc. complete and as directed by Engineer Incharge.-GROUND FLOOR
DRESSING TABLE - Providing and fixing in position DRESSING TABLE-1.200X0.450x 0.750 meter size & vertical mirror 1.800 x 1.200 meter in the Room, wooden structure as per detail drawing with 18 mm thick commercial plywood Conforming IS 303:1989 on surface Also granite top on ,all the edges to be finished with best quality teakwood bidding patti of size 1/2 inch. All surfaces to be finished with Telephone Black Granite as per drawing . Adhesives used shall be low-VOC compliant. Including applying mealamine polish to all wood work,Including handles 150mm, Iron hinges, slidding strip channels, magnetic ball catcher, concealed lock, nails & screw and installation shall be in true line & level complete with necessary provision for electrical switches & wiring if any.Including all leads, lifts at all levels etc. complete and as directed by Engineer Incharge. .-GROUND FLOOR
DRESSING TABLE - Providing and fixing in position DRESSING TABLE-1.200X0.450x 0.750 meter size & vertical mirror 1.800 x 1.200 meter in the Room, wooden structure as per detail drawing with 18 mm thick commercial plywood Conforming IS 303:1989 on surface Also granite top on ,all the edges to be finished with best quality teakwood bidding patti of size 1/2 inch. All surfaces to be finished with Telephone Black Granite as per drawing . Adhesives used shall be low-VOC compliant. Including applying mealamine polish to all wood work,Including handles 150mm, Iron hinges, slidding strip channels, magnetic ball catcher, concealed lock, nails & screw and installation shall be in true line & level complete with necessary provision for electrical switches & wiring if any.Including all leads, lifts at all levels etc. complete and as directed by Engineer Incharge. .-FIRST FLOOR
TV CABINET-Providing and fixing in position TV CABINET 2.50 X 0.300 X 0.600 meter size in the Room, wooden structure as per detail drawing with 18 mm thick commercial plywood Conforming IS 303:1989 on surface Also granite top table ,all the edges to be finished with best quality teakwood bidding patti of size 1/2 inch. All surfaces to be finished with Telephone Black Granite as per drawing . Adhesives used shall be low-VOC compliant. Including applying mealamine polish to all wood work, Including handles 150mm, Iron hinges, slidding strip channels, magnetic ball catcher, concealed lock, nails & screw and installation shall be in true line & level complete with necessary provision for electrical switches & wiring if any.Including all leads, lifts at all levels etc. complete and as directed by Engineer Incharge. -GROUND FLOOR
TV CABINET-Providing and fixing in position TV CABINET 2.50 X 0.300 X 0.600 meter size in the Room, wooden structure as per detail drawing with 18 mm thick commercial plywood Conforming IS 303:1989 on surface Also granite top table ,all the edges to be finished with best quality teakwood bidding patti of size 1/2 inch. All surfaces to be finished with Telephone Black Granite as per drawing . Adhesives used shall be low-VOC compliant. Including applying mealamine polish to all wood work, Including handles 150mm, Iron hinges, slidding strip channels, magnetic ball catcher, concealed lock, nails & screw and installation shall be in true line & level complete with necessary provision for electrical switches & wiring if any.Including all leads, lifts at all levels etc. complete and as directed by Engineer Incharge. FIRST FLOOR
DINNING TABLE -Providing and fixing in position DINNING TABLE 2.10 X 1.10 X 0.750 meter size in the Room, wooden structure as per detail drawing with 18 mm thick commercial plywood Conforming IS 303:1989 on surface Also granite top on luggage & survice table ,all the edges to be finished with best quality teakwood bidding patti of size 1/2 inch. All surfaces to be finished with Telephone Black Granite as per drawing . Adhesives used shall be low-VOC compliant. Including applying mealamine polish to all wood work, Including nails & screw and installation shall be in true line & level complete with necessary provision for electrical switches & wiring if any.Including all leads, lifts at all levels etc. complete and as directed by Engineer Incharge.-GROUND FLOOR
WALDROBE-Providing and fixing in position WALDROBE size 2.40 X 2.40 X 0.60 meter in the Room, wooden structure as per detail drawing with 18 mm thick commercial plywood Conforming IS 303:1989 on surface,all the edges to be finished with best quality teakwood bidding patti of size 1/2 inch. All surfaces to be finished with 1 mm thick white mica laminate as per drawing . Adhesives used shall be low-VOC compliant. Including applying mealamine polish to all wood work, Including handles 150mm, Iron hinges, slidding strip channels, magnetic ball catcher, concealed lock, nails & screw and installation shall be in true line & level complete with necessary provision for electrical switches & wiring if any.Including all leads, lifts at all levels etc. complete and as directed by Engineer Incharge.-GROUND FLOOR
WALDROBE-Providing and fixing in position WALDROBE size 2.40 X 2.40 X 0.60 meter in the Room, wooden structure as per detail drawing with 18 mm thick commercial plywood Conforming IS 303:1989 on surface,all the edges to be finished with best quality teakwood bidding patti of size 1/2 inch. All surfaces to be finished with 1 mm thick white mica laminate as per drawing . Adhesives used shall be low-VOC compliant. Including applying mealamine polish to all wood work, Including handles 150mm, Iron hinges, slidding strip channels, magnetic ball catcher, concealed lock, nails & screw and installation shall be in true line & level complete with necessary provision for electrical switches & wiring if any.Including all leads, lifts at all levels etc. complete and as directed by Engineer Incharge.-FIRST FLOOR
STORAGE-Providing and fixing in position WALDROBE size 1.20 X 2.40 X 0.60 meter in the Room, wooden structure as per detail drawing with 18 mm thick commercial plywood Conforming IS 303:1989 on surface,all the edges to be finished with best quality teakwood bidding patti of size 1/2 inch. All surfaces to be finished with 1 mm thick white mica laminate as per drawing . Adhesives used shall be low-VOC compliant. Including applying mealamine polish to all wood work, Including handles 150mm, Iron hinges, slidding strip channels, magnetic ball catcher, concealed lock, nails & screw and installation shall be in true line & level complete with necessary provision for electrical switches & wiring if any.Including all leads, lifts at all levels etc. complete and as directed by Engineer Incharge.-GROUND FLOOR
STORAGE-Providing and fixing in position WALDROBE size 1.20 X 2.40 X 0.60 meter in the Room, wooden structure as per detail drawing with 18 mm thick commercial plywood Conforming IS 303:1989 on surface,all the edges to be finished with best quality teakwood bidding patti of size 1/2 inch. All surfaces to be finished with 1 mm thick white mica laminate as per drawing . Adhesives used shall be low-VOC compliant. Including applying mealamine polish to all wood work, Including handles 150mm, Iron hinges, slidding strip channels, magnetic ball catcher, concealed lock, nails & screw and installation shall be in true line & level complete with necessary provision for electrical switches & wiring if any.Including all leads, lifts at all levels etc. complete and as directed by Engineer Incharge.--FIRST FLOOR
STORAGE-Providing and fixing in position WALDROBE size 1.20 X 2.40 X 0.60 meter in the Room, wooden structure as per detail drawing with 18 mm thick commercial plywood Conforming IS 303:1989 on surface,all the edges to be finished with best quality teakwood bidding patti of size 1/2 inch. All surfaces to be finished with 1 mm thick white mica laminate as per drawing . Adhesives used shall be low-VOC compliant. Including applying mealamine polish to all wood work, Including handles 150mm, Iron hinges, slidding strip channels, magnetic ball catcher, concealed lock, nails & screw and installation shall be in true line & level complete with necessary provision for electrical switches & wiring if any.Including all leads, lifts at all levels etc. complete and as directed by Engineer Incharge.--SECOND FLOOR
THREE SEATER BENCH- Providing and fixing of size 48''lx15''wx18''H precast m20 grade,10 mm tmt steel, mixed with longlasting full body pigmented color in cement& water proof chemical like nature wooden color also comes in part with 3planks & 2legs fitted with steel nuts & bolts(with sealed with plastic nobs),as per drawing.etc complete. -GROUND FLOOR
WAITING AREA BENCH- Providing and fixing of size 4'L x 18'' w x 18''H , 3'' Thick of two web & single flange ,precast m20 grade cement concrete with 10 mm tmt steel, colour superfine chips, mirror polish finish ,as per drawing.etc complete..-GROUND FLOOR
WALL MURAL :- Supply and installation of wall mural in 20 - 25 mm Sandstone with carving depth of 2-3 mm according to specified design. Pasted on wall using UV resistant stone adhesive and necessary precautions. With water repellent PU coating on surface , as per drawing.etc complete.RA NO 15.-GROUND FLOOR
FULL HEIGHT PLY PARTITION WALL-Full Height Partitions in Solid finish Providing and Fixing 80mm to 85mm thick Full height Double Skin partition up to 3 mtr height with All visible sections in Anodized / Powder coated finish. Made up of Frames and Tiles. Frame construction In combinaton of Aluminium Rails and Bottom ,Center and Top members, Connected with 2 way Round Shape Post , 3way Post , 4 way Post made up of Aluminium Extruded and Tiles in 9mm thk. Prelaminated Partical Board of on both side. With all the Joints in the partitions covered with PVC extrusions to provide better sound Proofing. Tiles to be separated 55mm from each other to provide adequate space for drawingcables for electric, data and telephone with proper facility for fixing electrical and data switchplates. as per design and drawing SSR 2020-21 Item No. 52.56 Page No. 432.-GROUND FLOOR
FULL HEIGHT PLY PARTITION WALL-Full Height Partitions in Solid finish Providing and Fixing 80mm to 85mm thick Full height Double Skin partition up to 3 mtr height with All visible sections in Anodized / Powder coated finish. Made up of Frames and Tiles. Frame construction In combinaton of Aluminium Rails and Bottom ,Center and Top members, Connected with 2 way Round Shape Post , 3way Post , 4 way Post made up of Aluminium Extruded and Tiles in 9mm thk. Prelaminated Partical Board of on both side. With all the Joints in the partitions covered with PVC extrusions to provide better sound Proofing. Tiles to be separated 55mm from each other to provide adequate space for drawingcables for electric, data and telephone with proper facility for fixing electrical and data switchplates. as per design and drawing SSR 2020-21 Item No. 52.56 Page No. 432-FIRST FLOOR
FULL HEIGHT PLY PARTITION WALL-Full Height Partitions in Solid finish Providing and Fixing 80mm to 85mm thick Full height Double Skin partition up to 3 mtr height with All visible sections in Anodized / Powder coated finish. Made up of Frames and Tiles. Frame construction In combinaton of Aluminium Rails and Bottom ,Center and Top members, Connected with 2 way Round Shape Post , 3way Post , 4 way Post made up of Aluminium Extruded and Tiles in 9mm thk. Prelaminated Partical Board of on both side. With all the Joints in the partitions covered with PVC extrusions to provide better sound Proofing. Tiles to be separated 55mm from each other to provide adequate space for drawingcables for electric, data and telephone with proper facility for fixing electrical and data switchplates. as per design and drawing SSR 2020-21 Item No. 52.56 Page No. 432 SECOND FLOOR
FULL HEIGHT GLASS WALL- Full Height Partitions in Glass finishProviding and Fixing 80mm to 85mm thick Full height Double Skin partition up to 3 mtr height with All visible sections in Anodized / Powdercoated finish. Made up of Frames and Tiles. Frame construction In combinaton of Aluminium Rails and Bottom ,Center and Top members, Connected with 2 way Round Shape Post , 3way Post , 4 way Post made up of Aluminium Extruded and Tiles in 5mm thk. Non Toughened Glass on both side. With all the Joints in the partitions covered with PVC extrusions to provide better sound Proofing. Tiles to be separated 55mm from each other to provide adequate space for drawing cables for electric, data and telephone with proper facility for fixing electrical and data switch plates. as per design and drawing.. SSR 2020-21 Item No. 52.57 Page No. 433.-GROUND FLOOR
FULL HEIGHT GLASS WALL- Full Height Partitions in Glass finishProviding and Fixing 80mm to 85mm thick Full height Double Skin partition up to 3 mtr height with All visible sections in Anodized / Powdercoated finish. Made up of Frames and Tiles. Frame construction In combinaton of Aluminium Rails and Bottom ,Center and Top members, Connected with 2 way Round Shape Post , 3way Post , 4 way Post made up of Aluminium Extruded and Tiles in 5mm thk. Non Toughened Glass on both side. With all the Joints in the partitions covered with PVC extrusions to provide better sound Proofing. Tiles to be separated 55mm from each other to provide adequate space for drawing cables for electric, data and telephone with proper facility for fixing electrical and data switch plates. as per design and drawing.. SSR 2020-21 Item No. 52.57 Page No. 433.-FIRST FLOOR
FULL HEIGHT GLASS WALL- Full Height Partitions in Glass finishProviding and Fixing 80mm to 85mm thick Full height Double Skin partition up to 3 mtr height with All visible sections in Anodized / Powdercoated finish. Made up of Frames and Tiles. Frame construction In combinaton of Aluminium Rails and Bottom ,Center and Top members, Connected with 2 way Round Shape Post , 3way Post , 4 way Post made up of Aluminium Extruded and Tiles in 5mm thk. Non Toughened Glass on both side. With all the Joints in the partitions covered with PVC extrusions to provide better sound Proofing. Tiles to be separated 55mm from each other to provide adequate space for drawing cables for electric, data and telephone with proper facility for fixing electrical and data switch plates. as per design and drawing.. SSR 2020-21 Item No. 52.57 Page No. 433.-SECOND FLOOR
LOW HEIGHT STORAGE UNIT --Credestal @ 1200Lx450Lx650HT Providing & Fixing of LOW HEIGHT CREDESTAL @1200L X 450D X 650H:-To be made out of Membrane Finish (2 Openable Shutter & 3 Drawer Pedestal in between ) as per drawing.SSR 2020-21 Item No. 51.23 Page No. 344-GROUND FLOOR
LOW HEIGHT STORAGE UNIT --Credestal @ 1200Lx450Lx650HT Providing & Fixing of LOW HEIGHT CREDESTAL @1200L X 450D X 650H:-To be made out of Membrane Finish (2 Openable Shutter & 3 Drawer Pedestal in between ) as per drawing.SSR 2020-21 Item No. 51.23 Page No. 344 FIRST FLOOR
Full Height Steel Storage @ 750Lx450Dx2100HT Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 4 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns as as per drawing.SSR 2020-21 Item No. 51.37 Page No. 348.-GROUND FLOOR
Full Height Steel Storage @ 750Lx450Dx2100HT Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 4 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns as as per drawing.SSR 2020-21 Item No. 51.37 Page No. 348. FIRST FLOOR
BED SIDE TABLE-@ 400LX 400DX 415H Providing and Fixing Bed Side Table of size 400LX 400DX 415H The bed side unit is madeup of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The bed side table has one drawer andone shelf. The shelf is made of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. SSR 2020-21 Item No. 51.58 Page No. 357.-GROUND FLOOR
BED SIDE TABLE-@ 400LX 400DX 415H Providing and Fixing Bed Side Table of size 400LX 400DX 415H The bed side unit is madeup of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The bed side table has one drawer andone shelf. The shelf is made of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. SSR 2020-21 Item No. 51.58 Page No. 357 FIRST FLOOR
COMPACTOR 01 -Single Faced Mobile Unit for Compactor 2150 mmH x 2745 mmW x 457mmD Providing and fixing Single Faced Mobile Unit for Compactor 2150mmH x2745mm Wx 457mmD-BASE FRAME: Base Frame shall be fabricated in channel Type from minimum2.5 mm thick MS Sheet Size of Channel 25mm x 100mm x 45mm.GUIDERAILS:The guide rails shallbe made out of 28mm Bright bar placed on 1.2mm thick M.S.Plate which will be above the floor and are as per the international standard of safety. SUPERSTRUCTURE: Superstructure of the Mobile storage system will consist of knock down type panels. All the components such as shelves ,front panel,end panel,vertical rear panel,central partition etc.Will act as an integral member of the Unit.SHELVES:Shelves made of 22SWG thick Prime Quality C.R.C.A.having10 folds each will be provided each designed to carrya U.D.L.of 70 Kilograms.VERTICALPANEL:Vertical panel consists of the front,Centre& rear panelshall be madeout of 20SWGthickC.R.C.A.Prime quality Mild Steel& designed to take the load of shelves.DRIVE COVER PANEL:Made outof 22SWG thick C.R.C.A.prime quality Steel to cover theentire drive mechanism.CENTREPARTITION : The Centre partition will comprise of afull C.R.C.A. prime quality Mild Steel 22SWG Sheet.LOCKING:System will be provided with individual rack locking as well as centralised locking arrangement on the last unit when all units are brought together,central lock when operated get slocked with the floor &does not allow access to the units. DRIVEMECHANISM: Driving Mechanism will be provided externally supported on special grade anti friction bearing to have smooth & effort less movement.Entire mechanism orgear & sprockets shall be in corporated with in the front panel provided in the front of the unit with in anarea of 1000mm x200mm x60mm. DRIVINGWHEEL: Fully Powder Coated three pronged drive wheel for better torque & free movement of the rack over the guide rail.INDEXING ARRANGEMENT:Acrylic cardholder sprovided on the front panel for easy identification & retrieval.FINALFINISH:Powder Coating (8tanksprocess with 70 microns).SSR 2020-21 Item No. 51.46 Page No. 350-GROUND FLOOR
COMPACTOR 01 -Single Faced Mobile Unit for Compactor 2150 mmH x 2745 mmW x 457mmD Providing and fixing Single Faced Mobile Unit for Compactor 2150mmH x2745mm Wx 457mmD-BASE FRAME: Base Frame shall be fabricated in channel Type from minimum2.5 mm thick MS Sheet Size of Channel 25mm x 100mm x 45mm.GUIDERAILS:The guide rails shallbe made out of 28mm Bright bar placed on 1.2mm thick M.S.Plate which will be above the floor and are as per the international standard of safety. SUPERSTRUCTURE: Superstructure of the Mobile storage system will consist of knock down type panels. All the components such as shelves ,front panel,end panel,vertical rear panel,central partition etc.Will act as an integral member of the Unit.SHELVES:Shelves made of 22SWG thick Prime Quality C.R.C.A.having10 folds each will be provided each designed to carrya U.D.L.of 70 Kilograms.VERTICALPANEL:Vertical panel consists of the front,Centre& rear panelshall be madeout of 20SWGthickC.R.C.A.Prime quality Mild Steel& designed to take the load of shelves.DRIVE COVER PANEL:Made outof 22SWG thick C.R.C.A.prime quality Steel to cover theentire drive mechanism.CENTREPARTITION : The Centre partition will comprise of afull C.R.C.A. prime quality Mild Steel 22SWG Sheet.LOCKING:System will be provided with individual rack locking as well as centralised locking arrangement on the last unit when all units are brought together,central lock when operated get slocked with the floor &does not allow access to the units. DRIVEMECHANISM: Driving Mechanism will be provided externally supported on special grade anti friction bearing to have smooth & effort less movement.Entire mechanism orgear & sprockets shall be in corporated with in the front panel provided in the front of the unit with in anarea of 1000mm x200mm x60mm. DRIVINGWHEEL: Fully Powder Coated three pronged drive wheel for better torque & free movement of the rack over the guide rail.INDEXING ARRANGEMENT:Acrylic cardholder sprovided on the front panel for easy identification & retrieval.FINALFINISH:Powder Coating (8tanksprocess with 70 microns).SSR 2020-21 Item No. 51.46 Page No. 350-FIRST FLOOR
COMPACTOR 02 -Double Faced Mobile Unit for Compactor 2150mmH x 2745mmW x 900mmD Providing and fixing Double Faced Mobile Unit for Compactor 2150mmH x2745mmW x900mmD-BASEFRAME:Base Frame shall be fabricated in channel Type from minimum2.5 mm thick MS Sheet Size of Channel 25mm x 100mm x 45mm.GUIDERAILS:The guide rails shall be made out of 28mm Bright bar placed on1.2mm thick M.S.Plate which will be above the floor and are as per the international standard of safety. SUPERSTRUCTURE:Superstructure of the Mobile storage system will consist of knock down type panels. All the component ssucha sshelves,f ront panel, end panel, vertical rear panel,central partition etc.Will act as anintegral member of the Unit.SHELVES:Shelves made of 22SWG thick Prime Quality C.R.C.A.having 10 folds each will be provided each designed to carrya U.D.L.of 70Kilograms.VERTICALPANEL:Vertical panel consists of the front,Centre &rearpanel shall be made out of 20SWG thick C.R.C.A.Prime quality Mild Steel & designed to take the load of shelves. As directed by Engineer-in-charge Number 135808---1851 DRIVE COVER PANEL: Made out of 22SWG thick C.R.C.A. prime quality Steel to cover the entire drive mechanism.CENTRE PARTITION:The Centre partition will comprise of afull C.R.C.A. prime quality Mild Steel 22SWG Sheet.LOCKING:System will be provided within dividual rack locking as well ascentralised locking arrangement on the last unit when all unit sarebrought together,central lock when operated gets locked with the floor &does not allow access to the units.DRIVE MECHANISM: Driving Mechanism will be provided externally supported on special grade anti-friction be aring to have smooth & effortless movement. Entire mechanism or gear &sprockets shall be incorporated with in the front panel provided in the front of the unit within an area of 1000mm x200mm x60mm. DRIVING WHEEL:Fully Powder Coated three pronged drive wheel for better torque & free movement of the rackover the guide rail.INDEX ING ARRANGEMENT:Acrylic cardholders provided on the front panel for easy identification & retrieval.FINAL FINISH: PowderCoating (8 tanks process with 70 microns).SSR 2020-21 Item No. 51.45 Page No. 349.-GROUND FLOOR
COMPACTOR 02 -Double Faced Mobile Unit for Compactor 2150mmH x 2745mmW x 900mmD Providing and fixing Double Faced Mobile Unit for Compactor 2150mmH x2745mmW x900mmD-BASEFRAME:Base Frame shall be fabricated in channel Type from minimum2.5 mm thick MS Sheet Size of Channel 25mm x 100mm x 45mm.GUIDERAILS:The guide rails shall be made out of 28mm Bright bar placed on1.2mm thick M.S.Plate which will be above the floor and are as per the international standard of safety. SUPERSTRUCTURE:Superstructure of the Mobile storage system will consist of knock down type panels. All the component ssucha sshelves,f ront panel, end panel, vertical rear panel,central partition etc.Will act as anintegral member of the Unit.SHELVES:Shelves made of 22SWG thick Prime Quality C.R.C.A.having 10 folds each will be provided each designed to carrya U.D.L.of 70Kilograms.VERTICALPANEL:Vertical panel consists of the front,Centre &rearpanel shall be made out of 20SWG thick C.R.C.A.Prime quality Mild Steel & designed to take the load of shelves. As directed by Engineer-in-charge Number 135808---1851 DRIVE COVER PANEL: Made out of 22SWG thick C.R.C.A. prime quality Steel to cover the entire drive mechanism.CENTRE PARTITION:The Centre partition will comprise of afull C.R.C.A. prime quality Mild Steel 22SWG Sheet.LOCKING:System will be provided within dividual rack locking as well ascentralised locking arrangement on the last unit when all unit sarebrought together,central lock when operated gets locked with the floor &does not allow access to the units.DRIVE MECHANISM: Driving Mechanism will be provided externally supported on special grade anti-friction be aring to have smooth & effortless movement. Entire mechanism or gear &sprockets shall be incorporated with in the front panel provided in the front of the unit within an area of 1000mm x200mm x60mm. DRIVING WHEEL:Fully Powder Coated three pronged drive wheel for better torque & free movement of the rackover the guide rail.INDEX ING ARRANGEMENT:Acrylic cardholders provided on the front panel for easy identification & retrieval.FINAL FINISH: PowderCoating (8 tanks process with 70 microns).SSR 2020-21 Item No. 51.45 Page No. 349-FIRST FLOOR
TABLE 01 :-Executive Table @2250Lx2100Dx750HT including Low Height Credestal @1200Lx 450Dx 650HT Providing & Fixing of Table @2250Lx2100Dx750HT TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18mm thick Prelaminated particle board with PVC edge band. INCLUDING CREDESTAL @1200LX450DX650H:-To be made out of Membrane Finish ( 2 Openable Shutter &3 Drawer Pedestal in between ) as per drawing.SSR 2020-21 Item No.51.24 Page No. 345. -GROUND FLOOR
TABLE 01 :-Executive Table @2250Lx2100Dx750HT including Low Height Credestal @1200Lx 450Dx 650HT Providing & Fixing of Table @2250Lx2100Dx750HT TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18mm thick Prelaminated particle board with PVC edge band. INCLUDING CREDESTAL @1200LX450DX650H:-To be made out of Membrane Finish ( 2 Openable Shutter &3 Drawer Pedestal in between ) as per drawing.SSR 2020-21 Item No.51.24 Page No. 345. -FIRST FLOOR
TABLE 02 :Executive's Table @ 1800Lx900Dx750HT Providing & Fixing of Table @1800Lx900Dx750HT-TOP & GABLEEND to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTYPANEL to be made of 18mm thick Prelaminated particle board with PVC edge band as per drawing. SSR 2020-21 Item No. 51.21 Page No. 344.-GROUND FLOOR
TABLE 02 :Executive's Table @ 1800Lx900Dx750HT Providing & Fixing of Table @1800Lx900Dx750HT-TOP & GABLEEND to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTYPANEL to be made of 18mm thick Prelaminated particle board with PVC edge band as per drawing. SSR 2020-21 Item No. 51.21 Page No. 344.-FIRST FLOOR
TABLE 03 :- Free Standing Table @ 1500Lx600Dx750HT Providing and fixing Table of Size 1500 x 600 x 750 mm. Top: made from 25 mm Commercial ply. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side Commercial ply.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm Commercial ply .SSR 2020-21 Item No. 51.26 Page No. 344-GROUND FLOOR
TABLE 03 :- Free Standing Table @ 1500Lx600Dx750HT Providing and fixing Table of Size 1500 x 600 x 750 mm. Top: made from 25 mm Commercial ply. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side Commercial ply.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm Commercial ply .SSR 2020-21 Item No. 51.26 Page No. 344--FIRST FLOOR
TABLE-04 -Free Standing Table @ 1200L x600Dx750HT Providing and fixing Table of Size1200 x600x 750mm.Top:made from 25 mm Prelaminated Particle board.All edges are covered by 2mm.Thk.PVC edge bands glued by hot melt glue applied by auto edge banding machine. Legs:CShape made from CRCA Sheet with PowderCoat finish.Mode sty panel:Made from 18 mm both side pre laminated particle boards. All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY (WITHOUT MOUSE TRAY):-Metal Powder Coated-Black Color,CPU TROLLEY:-Metal Powder Coated-Black Color,3 DRAWER PEDESTAL UNIT having over all size 392L x450D x680Ht.mm.with central lock and key.Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board, SSR 2020-21 Item No. 51.28 Page No. 346.-GROUND FLOOR
TABLE-04 -Free Standing Table @ 1200L x600Dx750HT Providing and fixing Table of Size1200 x600x 750mm.Top:made from 25 mm Prelaminated Particle board.All edges are covered by 2mm.Thk.PVC edge bands glued by hot melt glue applied by auto edge banding machine. Legs:CShape made from CRCA Sheet with PowderCoat finish.Mode sty panel:Made from 18 mm both side pre laminated particle boards. All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY (WITHOUT MOUSE TRAY):-Metal Powder Coated-Black Color,CPU TROLLEY:-Metal Powder Coated-Black Color,3 DRAWER PEDESTAL UNIT having over all size 392L x450D x680Ht.mm.with central lock and key.Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board, SSR 2020-21 Item No. 51.28 Page No. 346 FIRST FLOOR
TABLE-04 -Free Standing Table @ 1200L x600Dx750HT Providing and fixing Table of Size1200 x600x 750mm.Top:made from 25 mm Prelaminated Particle board.All edges are covered by 2mm.Thk.PVC edge bands glued by hot melt glue applied by auto edge banding machine. Legs:CShape made from CRCA Sheet with PowderCoat finish.Mode sty panel:Made from 18 mm both side pre laminated particle boards. All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY (WITHOUT MOUSE TRAY):-Metal Powder Coated-Black Color,CPU TROLLEY:-Metal Powder Coated-Black Color,3 DRAWER PEDESTAL UNIT having over all size 392L x450D x680Ht.mm.with central lock and key.Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board, SSR 2020-21 Item No. 51.28 Page No. 346 SECOND FLOOR
TABLE 05 -12 Seater Reading Table for Library @ 3600Lx1200Dx750HT Providing and Fixing 12 Seater Reading Table for Liberary @ 3600Lx1200Dx750HT Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Gable Ends : made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.SSR 2020-21 Item No. 51.33 Page No. 348.-FIRST FLOOR
TABLE 06 :- Free Standing Table @ 1350Lx600Dx750HT Providing and fixing Table of Size 1350x600x750mm. Top:made from25mm Prelaminated Particle board.All edges are covered by2mm.Thk.PVC edge bands glued by hot melt glue applied by auto edge banding machine. Legs:C Shape made fromC RCA Sheet with Powder Coat finish.Mode stypanel :Made from 18 mm both side prelaminated particle boards.All edge sare covered by 0.8mm PVC edge band sglued by hot melt glue applied by auto edge banding machine.KEY BOARD TRAY (WITHOUT MOUSE TRAY):-MetalPowderCoated-BlackColor,CPUTROLLEY:-MetalPowderCoated-Black Color,3DRAWER PEDESTAL UNIT having overall size 392Lx450Dx680Ht.mm.with central lock and key.Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board. SSR 2020-21 Item No. 51.27 Page No. 346.-GROUND FLOOR
TABLE 08 - Conference Table @ 3600Lx1400Dx750HT Providing & Fixing of Main Table @ 3600Lx1400Dx750HT - made up of 18+18mm Thick MDF top with PVC Membrane finish and waterfall edge profile. Aluminium Anodizied finish beeding of 4mm thich is running all over the table top edge. Gable ends is Aerofoiled Shape with front edges in PVC Membrane finish and rest in Prelaminated MDF with batton structure. Gable ends should be hollow from inside for the provision of passing electrical and Data wiring. , MODESTY PANEL:- to be made of 18 mm thick Prelaminated particle board with PVC edge band Access Flap:- For Wire manager 2 Nos. SSR 2020-21 Item No. 51.32 Page No. 347 -SECOND FLOOR
CARPET-Providing & Fixing in position, Carpet more than 800+ gsm, made with100% stain proof fibres of approved make along with 5mm underlay as per Architectural & Acoustical Design & Instructions & Complete in all aspects including all materials labour,finishing etc complete.SSR 2020-21 Item No. 51.13 Page No. 343.-GROUND FLOOR
CARPET-Providing & Fixing in position, Carpet more than 800+ gsm, made with100% stain proof fibres of approved make along with 5mm underlay as per Architectural & Acoustical Design & Instructions & Complete in all aspects including all materials labour,finishing etc complete.SSR 2020-21 Item No. 51.13 Page No. 343.-FIRST FLOOR
TEA TABLE- Tea Table 900mm X 750mm X 450mm for m.s. ante chamber Providing And Fixing Of Tea Table 900mm X750mm X450mm With 12mm Thick Colour Eitched Tempered Glass With Bevelled Drawing Made Out Of 18mm Thic Waterproofing Ply.The Outer Laces To Be Finished With High Quality 4Mm Thik Veneer Or 1Mm Thik Mica Etc.SSR 2020-21 Item No. 51.54 Page No. 355.-GROUND FLOOR
TEA TABLE- Tea Table 900mm X 750mm X 450mm for m.s. ante chamber Providing And Fixing Of Tea Table 900mm X750mm X450mm With 12mm Thick Colour Eitched Tempered Glass With Bevelled Drawing Made Out Of 18mm Thic Waterproofing Ply.The Outer Laces To Be Finished With High Quality 4Mm Thik Veneer Or 1Mm Thik Mica Etc.SSR 2020-21 Item No. 51.54 Page No. 355. FIRST FLOOR
CHAIR 01-Providing & Arrangemnt of High Back,Synchronized Mechanism with Multiple Locking,Adjustable Armrest ,Gaslift for Seat height adjustment,Standard 5-prong P/Nylon Base with Leatherite Upholstery. SSR 2020-21 Item No. 51.40 Page No. 249-GROUND FLOOR
CHAIR 01-Providing & Arrangemnt of High Back,Synchronized Mechanism with Multiple Locking,Adjustable Armrest ,Gaslift for Seat height adjustment,Standard 5-prong P/Nylon Base with Leatherite Upholstery. SSR 2020-21 Item No. 51.40 Page No. 249-FIRST FLOOR
CHAIR 01-Providing & Arrangemnt of High Back,Synchronized Mechanism with Multiple Locking,Adjustable Armrest ,Gaslift for Seat height adjustment,Standard 5-prong P/Nylon Base with Leatherite Upholstery. SSR 2020-21 Item No. 51.40 Page No. 249--SECOND FLOOR
CHAIR 02-Providing & Arrangemnt of High Back Chair-TILT MECHANISM WITH MULTILOCKING, HIGH DENSITY CUSHION ON SEAT COMPOSITE LEATHER WITH METALLIC SILVER FINISH BASE AND ARM SWITHP.U.CAST OR S GAS LIFTFOR HEIGHT ADJUSTMENT. SSR 2020-21 Item No. 51.41 Page No. 249-GROUND FLOOR
CHAIR 02-Providing & Arrangemnt of High Back Chair-TILT MECHANISM WITH MULTILOCKING, HIGH DENSITY CUSHION ON SEAT COMPOSITE LEATHER WITH METALLIC SILVER FINISH BASE AND ARM SWITHP.U.CAST OR S GAS LIFTFOR HEIGHT ADJUSTMENT. SSR 2020-21 Item No. 51.41 Page No. 249 FIRST FLOOR
CHAIR 02-Providing & Arrangemnt of High Back Chair-TILT MECHANISM WITH MULTILOCKING, HIGH DENSITY CUSHION ON SEAT COMPOSITE LEATHER WITH METALLIC SILVER FINISH BASE AND ARM SWITHP.U.CAST OR S GAS LIFTFOR HEIGHT ADJUSTMENT. SSR 2020-21 Item No. 51.41 Page No. 249 SECOND FLOOR
CHAIR 03-Providing & Arrangemnt of MIdBack ,Normal Syncro Mechanism, Fixed Armrest ,Gas lift for Seat height adjustment, Standard 5-prong/Nylon Base with Leather Upholstery. SSR 2020-21 Item No. 51.42 Page No. 249-GROUND FLOOR
CHAIR 03-Providing & Arrangemnt of MIdBack ,Normal Syncro Mechanism, Fixed Armrest ,Gas lift for Seat height adjustment, Standard 5-prong/Nylon Base with Leather Upholstery. SSR 2020-21 Item No. 51.42 Page No. 249 FIRST FLOOR
CHAIR 04-Providing & Arrangemnt of MidBack ,ECOCTS Mechanism,Fixed Armrest, Gas lift for Seat height adjustment, Standard 5-prong P/Nylon Base with Fabric Upholstery SSR 2020-21 Item No. 51.43 Page No. 249-GROUND FLOOR
CHAIR 04-Providing & Arrangemnt of MidBack ,ECOCTS Mechanism,Fixed Armrest, Gas lift for Seat height adjustment, Standard 5-prong P/Nylon Base with Fabric Upholstery SSR 2020-21 Item No. 51.43 Page No. 249-FIRST FLOOR
Sofa Set 3+1+1 Providing & fixing Sofa Set 3+1+1Brown and Cream leather DIMENSION Length:182.5(cms) Breadth (cms) :100(cms) Height(cms):100(cms) Weight (Kilograms) :66 (Kilogram) Seating Capacity: Five Seat SSR 2020-21 Item No. 51.53 Page No. 355.-GROUND FLOOR
Sofa Set 3+1+1 Providing & fixing Sofa Set 3+1+1Brown and Cream leather DIMENSION Length:182.5(cms) Breadth (cms) :100(cms) Height(cms):100(cms) Weight (Kilograms) :66 (Kilogram) Seating Capacity: Five Seat SSR 2020-21 Item No. 51.53 Page No. 355.-FIRST FLOOR
STOOL-Stool for Lab and Class-IV Providing and fixing 4 legged Lab stool,Legs made of 16Guage 45MM Outer dimension MSPipe ,Duly painted,With a304 Grade Stainless steel 12inch wide seat with a1inch collar,Height adjustment via a screw.as per design and drawing and instructions of Engineer in charge.SSR 2020-21 Item No. 51.51 Page No. 355.-FIRST FLOOR
PUBLIC SEATING CHAIR- Public Seating Chair. - 3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish..SSR 2020-21 Item No. 51.44 Page No. 349-GROUND FLOOR
PUBLIC SEATING CHAIR- Public Seating Chair. - 3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish..SSR 2020-21 Item No. 51.44 Page No. 349-- FIRST FLOOR
Wardrobe with Mirror @ 900LX 600DX 1965H Providing and Fixing Wardrobe with Mirror of size 900L X600D X1965H The wardrobe side panels and door sare made up of 18mm thick Prelam Particle Board wih both side decorative laminate.All exposeded gesare sealed with 2mm thick PVCedge Banding.The shelves are made of 18mm thick Prelam Particle Board with decorative laminate on both sides.The top is made of 36mm prelam particle board with decorative laminate on both sides.(18mm Prelam Particle board and 18mm batonson all side sto achieve 36 mm over all thickness).The exposeded ges of the top are sealed with 2 mm thick PVC edge Banding.The top most part of the wardrobe has an aluminum hanger rod of EBCO make.One drawer of size 400 (W) x 150(H) x 450 (D) made of 18mm thick prelam Particle Board has been considered.The drawer will have amultipurpose lock of EBCO premiumm ake.The wardrobe handles are S at in SS finish of 160 mm pitch.The wardrobe has amultipurpose lock of EBCO make.All hinges considered are Hettich make.Necessary good quality hardwares have been considered as required.SSR 2020-21 Item No. 51.57 Page No. 457.-GROUND FLOOR
Wardrobe with Mirror @ 900LX 600DX 1965H Providing and Fixing Wardrobe with Mirror of size 900L X600D X1965H The wardrobe side panels and door sare made up of 18mm thick Prelam Particle Board wih both side decorative laminate.All exposeded gesare sealed with 2mm thick PVCedge Banding.The shelves are made of 18mm thick Prelam Particle Board with decorative laminate on both sides.The top is made of 36mm prelam particle board with decorative laminate on both sides.(18mm Prelam Particle board and 18mm batonson all side sto achieve 36 mm over all thickness).The exposeded ges of the top are sealed with 2 mm thick PVC edge Banding.The top most part of the wardrobe has an aluminum hanger rod of EBCO make.One drawer of size 400 (W) x 150(H) x 450 (D) made of 18mm thick prelam Particle Board has been considered.The drawer will have amultipurpose lock of EBCO premiumm ake.The wardrobe handles are S at in SS finish of 160 mm pitch.The wardrobe has amultipurpose lock of EBCO make.All hinges considered are Hettich make.Necessary good quality hardwares have been considered as required.SSR 2020-21 Item No. 51.57 Page No. 457.-FIRST FLOOR
SINGLE BED- @ 2025LX 1000DX 650H Providing and fixing Single Bed of Size 2025Lx1000Dx650H with matress and pillow. Understructure: - The legs are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2 mm. The legs should have corner brackets welded to it at two levels. The corner brackets are made of 2mm thick CRCA having a L shaped structure to join the side panels and headboard to the leg. Three nos. of Horizontal stiffeners are provided at equal intervals. The stiffeners are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. The middle Horizontal Stiffener has a leg attached to it to transfer the load to the ground and add to the strength and stability of the complete structure. This leg is also made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. All Metal components to undergo 7 tank treatment process and should be powder coated to the thickness of minimum 50 Microns DFT. As directed by Engineer-incharge Number 19367 --Side Panel: - The side panels are made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The overall width of the side panel is 150mm. The side panels have 18mm thick prelam particle board Baton running for required length to add rigidity to the structure. Head Board :- The head board is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 650mm. Foot Board :- The foot board is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 450mm. Bed Base: - The Bed Base is made up of 12mm thick Prelam Particle Board with both side White laminate. 1867 . SSR 2020-21 Item No. 51.55 Page No. 356.-GROUND FLOOR
SINGLE BED- @ 2025LX 1000DX 650H Providing and fixing Single Bed of Size 2025Lx1000Dx650H with matress and pillow. Understructure: - The legs are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2 mm. The legs should have corner brackets welded to it at two levels. The corner brackets are made of 2mm thick CRCA having a L shaped structure to join the side panels and headboard to the leg. Three nos. of Horizontal stiffeners are provided at equal intervals. The stiffeners are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. The middle Horizontal Stiffener has a leg attached to it to transfer the load to the ground and add to the strength and stability of the complete structure. This leg is also made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. All Metal components to undergo 7 tank treatment process and should be powder coated to the thickness of minimum 50 Microns DFT. As directed by Engineer-incharge Number 19367 --Side Panel: - The side panels are made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The overall width of the side panel is 150mm. The side panels have 18mm thick prelam particle board Baton running for required length to add rigidity to the structure. Head Board :- The head board is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 650mm. Foot Board :- The foot board is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 450mm. Bed Base: - The Bed Base is made up of 12mm thick Prelam Particle Board with both side White laminate. 1867 . SSR 2020-21 Item No. 51.55 Page No. 356.-FIRST FLOOR
ROLLER BLINDS-Providing and Fixing Rollar Blinds AMI Make or approved make & shade of 38 mm round Aluminium channel with Black out fabric & telting with chain (Ball) system with all necessary fixtures and fitting etc.complete.(Sample to be final by Engineer In-charge prior execution of work). SSR 2020-21 Item No. 51.19 Page No. 344.-GROUND FLOOR
ROLLER BLINDS-Providing and Fixing Rollar Blinds AMI Make or approved make & shade of 38 mm round Aluminium channel with Black out fabric & telting with chain (Ball) system with all necessary fixtures and fitting etc.complete.(Sample to be final by Engineer In-charge prior execution of work). SSR 2020-21 Item No. 51.19 Page No. 344 -FIRST FLOOR
CLADDING-Bamboowood 10mm thick Wall Cladding including Threshold &T-mold-Providing & fixing in position Phenolbonded Bamboowood wall cladding at all height with planks of sizes 10mm thick,1900 mm length (minimum) and 135mm wide approved colour,texture and finish,having Performance Appraisal Certificate (PAC) issued by Building materials &Technology Promotion Council (BMTPC).with necessary profiled edges fixed with BRnailst of rame work made of second class teak wood of size 50x50 mm incentre and ends of each tile.The bamboowood cladding shall be laid over teakwood frame and hold in place by 50mm thick teak wood place dincentre of two teakwood and back layment and cvered with 1.00mm thick expanded polyethylene foam of density 25Kilogram/cum in two layers first layer on wall surface before fixing wooden frame and second layer on frame under cladding.The Bamboowood plank ssh all have minimum density of 1000Kilogram/cum & minimum Hardness 1000 Kilogramf.with Ecofriendly UV coating,all complete as per direction of Engineer in-charge.SSR 2020-21 Item No. 48.60 Page No. 305.-GROUND FLOOR
CLADDING-Bamboowood 10mm thick Wall Cladding including Threshold &T-mold-Providing & fixing in position Phenolbonded Bamboowood wall cladding at all height with planks of sizes 10mm thick,1900 mm length (minimum) and 135mm wide approved colour,texture and finish,having Performance Appraisal Certificate (PAC) issued by Building materials &Technology Promotion Council (BMTPC).with necessary profiled edges fixed with BRnailst of rame work made of second class teak wood of size 50x50 mm incentre and ends of each tile.The bamboowood cladding shall be laid over teakwood frame and hold in place by 50mm thick teak wood place dincentre of two teakwood and back layment and cvered with 1.00mm thick expanded polyethylene foam of density 25Kilogram/cum in two layers first layer on wall surface before fixing wooden frame and second layer on frame under cladding.The Bamboowood plank ssh all have minimum density of 1000Kilogram/cum & minimum Hardness 1000 Kilogramf.with Ecofriendly UV coating,all complete as per direction of Engineer in-charge.SSR 2020-21 Item No. 48.60 Page No. 305.-FIRST FLOOR
GLASS DOOR- Providing and fixing glass door size 1.0m/1.2m x 2.7m single leaf shutter of 12 mm thick toughen glass frosting and edge polish as shown in the drawings or as directed, including all necessary fittings like hydraulic patch fitting, top patch fittings, Top pivot, door handle, door lock, door stopper, door soft central 180 weather seal for door edges etc. complete as directed by Engineer -IN-Charge. RANO.16-GROUND FLOOR
GLASS DOOR- Providing and fixing glass door size 1.0m/1.2m x 2.7m single leaf shutter of 12 mm thick toughen glass frosting and edge polish as shown in the drawings or as directed, including all necessary fittings like hydraulic patch fitting, top patch fittings, Top pivot, door handle, door lock, door stopper, door soft central 180 weather seal for door edges etc. complete as directed by Engineer -IN-Charge. RANO.16 FIRST FLOOR
VERTICAL BLINDS-Providing and Fixing Vertical Blinds of approved Make and shade of 100mm regular fabric with powder coated aluminium channel with telting PVC chain & bottom weight plate with all necessary fixtures and fitting etc.complete.(Sample to be final by Engineer In-chargeprior execution of work)SSR 2020-21 Item No. 51.20 Page No. 344.-GROUND FLOOR
VERTICAL BLINDS-Providing and Fixing Vertical Blinds of approved Make and shade of 100mm regular fabric with powder coated aluminium channel with telting PVC chain & bottom weight plate with all necessary fixtures and fitting etc.complete.(Sample to be final by Engineer In-chargeprior execution of work)SSR 2020-21 Item No. 51.20 Page No. 344-FIRST FLOOR
Kitchen Trolley -Providing and Fixing stainless steel kitchen trolley of overall 26 " height and 22" depth,supported on aluminium pipes ,trolley basket made out of 5 mm stainless steel rod fitted on telescopic channel of size 1.5 " x 20 " x 22 " on both sides of trolley of 12 " or above size, panel having 40Kilogramload bearing capacity of trolley made out of 20 mm PUC coated plywood and colour combination as directed by E-I-C.Inner side of panel covered by white mica ,100 mm s.s. decorative handle.(The width and height of individual compartments shall be kept as directed by Engineer-in-charge) SSR 2020-21 Item No. 51.59 Page No. 357.-GROUND FLOOR
WOODEN FLOORING-Bamboowood 14 mm thick Tile Flooring including quarter round & door reducer-Providing & fixing in position Phenol bonded Epitome Bamboowood flooring with planks of sizes 14 mm thick ,1800 mm length (minimum) and 130 mm wide (minimum),in approved colour,texture and finish, having Performance Appraisal Certificate (PAC) issued by Building materials &Technology Promotion Council (BMTPC).The flooring shall be fixed with tongue and groove in terlocaking system,with 2 mm underlay as sound abrobing and moisture barrier and under layment of 4mm thick expanded polyethylene foam sheets having density 40 Kilogram/cum,over prepared surface with necessary quarter round planks of size 1900mmx18mm and dorr reducer of size 1900mm x44mm,wherever required.The Epitome Bamboowood planks shall have minimum density of 1000Kilogram/cum & minimum Hardness 1000 Kilogram f.with Ecofriendly UV coating,all complete as perdirection of Engineer in-chargeSSR 2020-21 Item No. 48.08 Page No. 296.-GROUND FLOOR
WOODEN FLOORING-Bamboowood 14 mm thick Tile Flooring including quarter round & door reducer-Providing & fixing in position Phenol bonded Epitome Bamboowood flooring with planks of sizes 14 mm thick ,1800 mm length (minimum) and 130 mm wide (minimum),in approved colour,texture and finish, having Performance Appraisal Certificate (PAC) issued by Building materials &Technology Promotion Council (BMTPC).The flooring shall be fixed with tongue and groove in terlocaking system,with 2 mm underlay as sound abrobing and moisture barrier and under layment of 4mm thick expanded polyethylene foam sheets having density 40 Kilogram/cum,over prepared surface with necessary quarter round planks of size 1900mmx18mm and dorr reducer of size 1900mm x44mm,wherever required.The Epitome Bamboowood planks shall have minimum density of 1000Kilogram/cum & minimum Hardness 1000 Kilogram f.with Ecofriendly UV coating,all complete as perdirection of Engineer in-chargeSSR 2020-21 Item No. 48.08 Page No. 296.FIRST FLOOR
WOODEN SKIRTING-Bamboowood 14mm thick wall Skirting - Providing & fixing in position Phenol bonded Epitome Bamboowood in wall skirting with planks of sizes 14mm thick, 1900mm length (minimum) and 85mm wide (minimum), in approved colour, texture and finish, having Performance Appraisal Certificate (PAC) issued by Building materials & Technology Promotion Council (BMTPC). The skirting shall be fixed SS screws & rawl plugs, over underlayment of 4mm thick expanded poly ethylene foam sheets having density 40Kilogram/cum, over prepared surface. The Epitome Bamboowood planks shall have minimum density 1000 Kilogram/cum & minimum Hardness 1000 Kilogramf. with Eco friendly UV coating, all complete as per direction of Engineer in-charge. SSR 2020-21 Item No. 48.09 Page No. 296.-GROUND FLOOR
WOODEN SKIRTING-Bamboowood 14mm thick wall Skirting - Providing & fixing in position Phenol bonded Epitome Bamboowood in wall skirting with planks of sizes 14mm thick, 1900mm length (minimum) and 85mm wide (minimum), in approved colour, texture and finish, having Performance Appraisal Certificate (PAC) issued by Building materials & Technology Promotion Council (BMTPC). The skirting shall be fixed SS screws & rawl plugs, over underlayment of 4mm thick expanded poly ethylene foam sheets having density 40Kilogram/cum, over prepared surface. The Epitome Bamboowood planks shall have minimum density 1000 Kilogram/cum & minimum Hardness 1000 Kilogramf. with Eco friendly UV coating, all complete as per direction of Engineer in-charge. SSR 2020-21 Item No. 48.09 Page No. 296.-FIRST FLOOR
STAGE FLOORING--Providing & fixing in position Stage flooring Made from 18mm plywood 1200 x 2400 & 18mm Teakwood planks 100 x 800 having tongue & grove on Sal-wood frame of 50 x 100 at 600mm c to c on stage surface including cost of required Cut-Outs, decorative mouldings / finishing-items / polish etc., as per Architectural & Acoustical Design & Instructions & Complete in all aspects. .including all materials labour,finishing etc complete.SSR 2020-21 Item No. 51.06 Page No. 342-GROUND FLOOR
STAGE FLOORING--Providing & fixing in position Stage flooring Made from 18mm plywood 1200 x 2400 & 18mm Teakwood planks 100 x 800 having tongue & grove on Sal-wood frame of 50 x 100 at 600mm c to c on stage surface including cost of required Cut-Outs, decorative mouldings / finishing-items / polish etc., as per Architectural & Acoustical Design & Instructions & Complete in all aspects. .including all materials labour,finishing etc complete.SSR 2020-21 Item No. 51.06 Page No. 342 FIRST FLOOR
Book Case with Glass Shutter @ 825Lx300Dx1650HT Providing & Fixing of Book Case with Glass Shutter @825Lx 300Dx 1650 HT :- To be made out of complete body & in 0.7mm thick CRCA & Shutter in 1.2mm thick CRCA with glass pannel in Powder coating finish as per drawing. SSR 2020-21 Item No. 51.39 Page No. 349.-FIRST FLOOR
FLUSH DOOR- Solid Core Flush door Single leaf Providing and fixing factory made solid core flush door in single leaf 35mm thick, decorative types,of exterior grade ,as per detailed drawings ,conforming to I.S.:2202-1962 (Revised) with approved face veneers on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads,moulding and lipping,holdfasts,mat finish stainless steel fixtures fastenings ,finishing with french-polish /waxing complete.(without door frame).(Sample to be got approved from Ex.Engineer before use) Commercial Hard Wood shutter.SSR 2020-21 Item No. 51.60 Page No. 358.-GROUND FLOOR
Gardening / Plantation.-Preparing Shrubbery - Excavating the ground to a required deapth of 30cms, removing rubbish & conveing unwanted stuff to a required distance as directed. Filling fresh garden soil & mannure in excavated area in 3:1 proportion to a height of 30cm, mixing gaarden soil and mannure throughly well, levelling watering on previous night planting well developed shrubs plants , 0.50m height , 0.45m apart as directd and maintaining till well established by watering, weedings, stirring replacing, replacing casualities etc complete.
ROSE Plants - Excavating Pit with Size 0.30m x 0.30m x 0.30m ramoving rubbish and conveying unwanted stuff to a required distance as directed. Fillthe pit with fresh garden soil and mannure in 1:3 proportion to a required ht of 0.3m . Mixing the soil and mannure throughly well, levelling, wateringon previous night. planning 40 to 50cm ht healthy plant of required rose variety. maintainging till well established by watering, weedings, stirring, pruning, replacing the casualaties etc complete.
Mogra Plant / Creepers / Climbers - Excavating Pit with Size 0.30m x 0.30m x 0.30m ramoving rubbish and conveying unwanted stuff to a required distance as directed. Fillthe the pit with approved excavated material up to a ht of 0.15m and remaining ht of 0.15m with fresh garden soil and mannure in 1:3 proportion to a required ht of 0.3m . Mixing the soil and mannure throughly well, levelling, wateringon previous night. planning 40 to 50cm ht healthy plant of required rose variety. maintainging till well established by watering, weedings, stirring, pruning, replacing the casualaties etc complete.
Planting large flowering / shaddy trees ( Ht. 2Mtr. ) :(Sacred fig, Neem, Spanish cherry, Golden shower tree, Dogbanes, Bauhinia variegate, Pongame oiltree, Burflower-tree, Sonchafa, Albizia lebbeck, coconut tree, golden bottle brush, green bamboo, Mango, Tamarind, Sapodilla, Custard apple, Arjun & Java Plum etc.) Digging pit with size 0.9m x 0.9m x 0.9m removing and conveying unwanted stuff to a required distance as directed. Filling the pit with approved excavated material up to a height of 0.30m and remaining height of 0.60m with fresh garden soil and manure in 3:1 proportion. Mixing soil and manure thoroughly well, levelling, as directed, watering previous night, planting one to two year old minium 2 mtr. height, healthy trees sapling as per specifications. Maintaining till well established by watering, weeding, stirring of soil replacing of casualities etc complete. Basic Rate As Per pune municipal corporation Parks and garden DSR 2017-18 Page NO.4 item no. 12
Land scaping-Preparing lawn ( 20cm Depth ) : Excavating the ground to a required depth of 20cms ,removing &conveying unwanted stuff to a required distance as directed.Filling fresh garden soil/silt & manure in excavated area in 3:1 proportion to a height of 20 cms. Mixing garden soil and manure thoroughly well,levelling ,and watering on previous night.Planting required variety of lawn grass as directed and maintaining till well established by watering, weeding, clipping , rolling,etc.complete.Basic Rate As Per pune municipal corporation Parks and garden DSR 2017-18 Page NO.2 item no.2
Preparing flower Bed : Excavating the ground to the required depth of 30 cms, removing and conveying unwanted stuff to a required distance as directed, filling fresh garden soil & manure in excavated area in 3:1 proportion to a required height of 30 cms mixing garden soil and manure thoroughly well,levelling, watering on previous night. Planting seeding of required annuals 25 cms. aprt maintaining till well established by watering, weeding, stirring replacing of casualties etc, complete. Basic Rate As Per pune municipal corporation Parks and garden DSR 2017-18 Page NO.3 item no.6
Providing and casting in situ or precast tapering R.C.C. M-20 Semi Barrier type Kerb without gutter ( as per IRC 86 1983) embedded 125mm below ground level over M-10 PCC finished neatly with C.M. 1:2, setting the same in C.M. 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batching and Mixing Plant
Irrigation System for Land Scaping-Piping Network- Mainline-Supply, installation, testing and commissioning of PVC Pipe of the size and Pressure rating as shown below, including the supply of all requisite Butt Join fittings etc as specified and as required complete. Make: Supreme/ Finolex-Main Pipeline Work-110 mm size X 6 kG/CM2
Submain Pipeline Work-Supply, installation, testing and commissioning of PVC/ ASTM Pipe as per IS 4985 of the size and pressure rating as shown below, including the supply of all requisite molded PVC fittings etc as specified and as required complete. Make: Finolex / Supreme -90mm x 6 Kg/Cm2
75mm x 6 Kg/Cm2
63mm x 6 Kg/Cm2
50mm x 6 Kg/Cm2
40mm x 6 Kg/Cm2
ASTM Pipe 2.5 " SCH 40
ASTM Pipe 2 " SCH 40
ASTM Pipe 1.5 " SCH 40
ASTM Pipe 1.25 " SCH 40
Valves and Valve Boxes-Supply, installation, testing and commissioning of Butterfly Valve as Mainline Isolation valves / Control valve of suitable size as per specifications including the cost of all fittings complete Make: Kartar Normex Audco -Valve on 110 mm Pipe
Valve on 90 mm Pipe
Valve on 75 mm Pipe
Supply, installation, testing and commissioning of Ball Valve as Control valve of suitable size as per specifications including the cost of all fittings complete. Make: Finolex /Jain /Equi-Valve on 63 mm Pipe
Valve on 50 mm Pipe
Valve on 40 mm Pipe
Supply, installation, testing and commissioning of 12" Rectangular Irrigation Control Valve Box etc complete Make: Cepex / Jain /Harit
Supply, installation, testing and commissioning of 10" round Irrigation Control Valve Box etc complete Make: Cepex / Jain /Harit
Supply, installation, testing and commissioning of Air Release Valves of 1" cast aluminium body for fixing on the mainline at regular intervals or at elevational changes as required with all fittings complete Make:Harit /ARI / Equi
Supply, installation, testing and commissioning of Quick coupling Valves 3/4" size of brass body for fixing on the mainline with all fittings complete Make:Harit /Equi
Supply, installation, testing and commissioning of 6" Round valve Box for housing the Quick Coupling valve & air release valve complete . Make:Cepex / Jain /Harit
Supply, installation, testing and commissioning of 40mm flush valve Make:Jain /Finloex
Sprinklers And accessories-Supply, installation, testing and commissioning of Rotor Sprinkler with popup height of 4" / 5" with Seal-a-matic low head drainage prevention seal and all other features including all accessories as per specification complete in various radii range as specified below. Make: Hunter-Sprinkler with radius of 8 m to 12m PGP Ultra with SAM , Arc & redius adjustabl technology
Sprinkler with 6-10 Mtr( PRO Spray with SAM –MP Rotator 3000 Nozzle )
Sprinkler with 2 - 5.5Mtr ( PRO Spray with SAM – 15ANozzle )
MP Rotator( 5-10 Mtr ) with shrub adapter with rising assembly including all fittinf MTA Complete
Spray Nozzle 15 A( 5-10 Mtr ) with shrub adapter with rising assembly including all fitting Complete
Swing Joint 3/4"
Swing Joint 1/2"
Drip Irrigation Equipment-Supply, installation, testing and commissioning of inline polytube having 16mm dia & 0.4 mtr spacing of dripper with all necessary fittings like take off, gromet, connectors, tees, elbows, end caps etc as required and specified complete Make: Netafim/ Finolex
Supply, installation, testing and commissioning of Plain polytube having 16mm dia with all necessary fittings like take off, gromet, connectors, tees, elbows, end caps etc as required and specified complete Make:Netafim/ Finolex
Supply, installation, testing and commissioning of Pressure complensatting dripper 8 LPH Make:Netafim/ Finolex
Supply, installation, testing and commissioning of lateral hoding stakes Make:Jain/ Netafim
Pumping System-Supply, installation, testing and commissioning Pumping system with each pump 10 LPS at 60 mtr head ( 1 W + 1S) mounted on a common skid Make: Lubi /CRI / Equiv.
Supply, installation, testing and commissioning of Control panel for 1 W + 1 S Pumping system
Supply, installation, testing and commissioning Non return valve 4 " with all fittings & accessories. Make:Normex /Kartar
Supply, installation, testing and commissioning Butterfly valve 4" with all fittings & accessories. Make:Normex /Kartar
Supply, installation, testing and commissioning of comman header assembly bypass assembly with including all fittings & accessories
Supply, installation, testing and commissioning of filtration unit with Sand Filter having capacity of 50 m3/hr. Unit along with 3" Screen filter etc complete. Make:Jain / Finolex/ Equi
INTERNAL ROAD-WBM Road Surface-Excavation for catch / side water gutter in Hard murum & Boulder strata to specified section including stacking excavated stuff in regular bund & disposing off unsuitable or excess stuff..
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification inciuding spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening / binding material to fill the interstices of coarse aggregate, watering and compacting with Vibratory roller to the required density. - By Mechanical Means - Grading I Using Screening type-A (13.2 milimetre Aggregate)
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening / binding material to fill the interstices of coarse aggregate, watering and compacting with Vibratory roller to the required density. - By Mechanical Means - Grading II Using Screening type-B (11.2 milimetre Aggregate)
Supplying hard murum / kankar at the road site, including conveying and stacking, excetra complete.
Spreading hard murum / soft murrum / gravel or kankar for side width, excetra complete.
Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering, excetra complete.
Bitumen Road Surfaces-Providing and constructing 50 milimetre thick modified penetration macadam road surface including all materials, preparing the existing road surface, spreading 40 milimetre stone metal layers 100 percent crusher broken metal with conical crusher plant, heating and spraying the bitumen of of specified grade at the rate of 1.75 kilogram per square metre, spreading 12 milimetre size chips, compacting with three wheel static roller having weight 8 to 10 metric tonnes to achive the desired degree of compaction as per technical specification Clause 506, excetra complete. Including picking of existing water bound macadam surface. (Using VG-30 bulk bitumen)
BITUMINOUS MACADAM:--Providing and laying bituminous macadam using crushed aggregate of Grading 1, premixed with bituminous binder, transported at site with VTS, laid over a previously prepared surface , finished to the required grade ,level, alignment,and rolling to achieve the desired density for 80/100 mm compacted thickness with drum mix type hot mix plant with SCADA having complying essential features of Hot mix plant as per IRC27 2009 specified conditions and attachments such as electronic load sensor based belt conveyers,automatic synchronization of bitumen and aggregate fedder,built in dust controller system and PLC for Drum Mix plant ,Sensor paver,and Vibratory roller excluding prime/Tack coat etc. complete --Bitumen 3.30% of specified grade (VG-30 bulk bitumen rates are considered to arrive at rates)
BITUMINOUS CONCRETE:--Providing and laying bituminous concrete using crushed aggregate of grading 1, premixed with bituminous binder @5.40% by weight of total mix and filler, transported at site with VTS, laid over a previously prepared surface, finished to the required grade ,level, alignment, and rolling to achieve the desired density for 50mm compacted thickness with drum mix plant with SCADA, Sensor paver and Vibratory roller excluding prime/Tack coat etc. complete --Bitumen of specified grade with stone dust filler. (VG-30 bulk bitumen rates are considered to arrive at rates)
Providing and applying tack coat on the prepared surface heating by fames in Boiler and spraying bitumen set footed in bitumen boller on B.T. surface 2.5 Kilogram/10 Square Metre.(VG-30 bulk bitumen rates are considered to arrive at rates)
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed.
Excavation for roadway in hard murum and boulder including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m.and spreading for embankment or stacking as directed.
Excavation for roadway in soft rock, including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. And spreading or stacking as directed.
Excavation for roadway in hard rock by controlled blasting including dressing section to the In Rs. required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stocking as directed.
Conveying materials obtained from road cutting including all lifts, laying in layers of 20cm to 30cm. breaking clods, dressing to the required lines, curves, grades and section, watering and compacting to not less than 97% of standard Proctor density for a lead of over 50m. to 300m. inclusive from the site of excavation to the site of deposition as directed.
Supplying Brick Bats at project site including conveying and stacking, excetra complete.
Supplying on site Garden Soil/ Red Soil well sieved 90% to pass through I.S. sieve of 10mm sixe free fromstones rubbish like dried grass roots and other such materials. The soil should be fress from quarry. The colour of the soil generally be Red. The soil will be measured by measuring box(Farma). ( Item includes Royalty Charges, Transporting,loading, unloading etc) lead for 20.00km is Considered.
Spreading /laying Brick Bats & Red Soil as per instructions by Engineer In Charge and in proper slope excetra complete.
Compacting the Brick bat Layer & Red Soil Layer with vibratory roller including artificial watering, excetra complete.
Providing detailed layout plan of area in scale 1:500 including carrying out contour survey and detailed Engineering plane table Survey with the help of 24"Alidade. The dolomite area measurement of the plot and structures, trees, over head line and underground service amenities within the area, with triangular method and giving detailes of the structures, such as total area, type of building and distance from all corners taking trial pit 0.5x0.5x2.00m.-2Nos. per acre and collection of record from city survey/D.I.L.R. authorities and authentication. The plan shall be traced on75micron polyster film and shall be submitted along with three Amonia prints.The contour levels shall be marked at 0.5 Meter intervals. Note:-The items includes-1)Traversing work with thedolite and steel tape. 2)Levelling Grid Work of the terrain. 3)Detailed Engineering Survey and contouring work of the terrain. 4)Plotting work. 5 )Collection of Record. b) above 1 Acre
Taking trial bores 75 to 100mm for 53.0 to 88.9mm core dia over burden (by diamond drilling machine)such as soil of all sorts, soft murum, hard murum and boulders and in soft rock including all materials such as casing pipes and accessorie soil,grease,steel, rods, and such other materials as required (including conveying the material to site of work). Preserving the loose sample in glass jar and core sample serially on site of work and conveying the same to HQ of concernring office as directed. a) over burden 0 to 50 meter.
Providing tuntappa core boxes of jungle wood of size 1.25m x 0.35 x 0.15m for preserving core sample with all fixtures and fastening handles including locking arrangment etc.complete.
Supplying & erecting HMS P.V.C. conduit 25 mm. dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. (1-1-9)
Supplying & laying HMS PVC conduit 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.(1-1-10)
Supplying & erecting HMS P.V.C. conduit 32 mm. dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. (1-1-11)
Supplying & laying HMS PVC conduit 32 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. (1-1-12)
Supplying & erecting mains with 1x1.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW (1-3-1) - with note 3
Supplying & erecting mains with 2x1.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW (1-3-1)
Supplying & erecting mains with 2x2.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW (1-3-3)
Supplying & erecting mains with 1x2.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW (1-3-3) - with note 3
Supplying & erecting mains with 2x4 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW (1-3-5)
Supplying & erecting mains with 1x4 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW (1-3-5) - with note 3
Supplying & erecting mains with 2x6 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW (1-3-7)
Supplying & erecting mains with 4x6 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW (1-3-7) - with note 1
Supplying & erecting mains with 4x10 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW (1-3-9) - with note 1
Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. (1-8-1)
Supplying and erecting ISI mark modular type switch 16A duly erected on provided plate and box with wiring connections complete. (1-8-2)
Supplying and erecting modular type switch 16 / 20 A with indicator, ISI mark, approved make duly erected on provided plate and box with wiring connections complete.(1-8-6)
Supplying and erecting ISI mark modular type 3 pin 6A multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete. (1-8-10)
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter ISI mark approved make duly erected on provided plate and box with wiring connections complete.(1-8-11)
Supplying and erecting ISI mark modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. Note: with two module box with double mounting plate.(1-8-23)
Supplying and erecting ISI mark modular type blanking plate one module, duly erected on provided plate & box.(1-8-24)
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.(1-8-34)
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.(1-8-35)
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.(1-8-36)
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.(1-8-38)
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.(1-8-40)
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 16/18 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. (1-8-41)
Point wiring for light/fan/bell concealed type in min 20 mm PVC conduit with 1.5 sq.mm. (2+1E) FR grade copper wires, moduler type switch, earthing and required accessaries as per specification No: WG-PW/CW(1-9-9)
Point wiring for light/fan/bell concealed type in min 20 mm PVC conduit with 1.5 sq.mm. (2+1E) FR grade copper wires, moduler type switch, earthing and required accessaries as per specification No: WG-PW/CW NOTE :- For point wiring in stair case with 2 way control point increase overall rate by 50 % of point wiring.(1-9-9)
Wiring for plug on board with Switch socket concealed type and copper wiring, earthing and with modular accessories as per specification No: WG-PW/CW (1-9-14)
Point wiring for light/fan/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FR grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW. (1-9-15)
Secondary point wiring for additional light/ bell point, concealed type in min 20 mm PVC conduit with 1.5 sq.mm. (2+1E) FR/FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW(1-9-22)
Supplying and erecting LED square / circular 5 to 8W down lighter having pressure die-cast aluminium housing,opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete. (2-1-2)
Supplying and erecting LED square / circular 9 to 12W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete. (2-1-3)
Supplying and erecting LED square / circular 13 to 15W down lighter having pressure die-cast aluminum housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete. (2-1-4)
Supplying and erecting LED square / circular 16 to 20W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete. (2-1-5)
Supplying and erecting CRCA /die-cast aluminium powder coated housing LED panel light (slim edge-lit) square / round shape suitable for 19 to 24 W with provision for plane front frame with translucent cover fixed to the housing complete.(2-1-9)
Supplying and erecting square shaped CRCA /die-cast aluminium powder coated housing LED panel light (slim edge-lit) 600x600mm suitable for 36 W-40W with provision for plane front frame with translucent cover fixed to the housing complete. (2-1-11)
Supplying LED concealed type foot / step light with aluminium body for indoor/outdoor application suitable for upto 4W-6W LED including driver and erecting by making necessary arrangement/recess in wall to make it flush with surface. (2-1-16)
Supplying & erecting LED 20W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete.(2-1-23)
Supplying and erecting LED mirror light with integrated driver including 7W to 9W lamp with polycarbonate housing and opal diffuser to be fixed above mirror or as required on clamps complete.(2-1-24)
Supplying & erecting 5W-8W, 230V integral type LED Lamp suitable for B-22/E-27 base.(2-1-29)
Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.(2-4-13)
Providing and erecting air circulator 450 mm. sweep oscillating type, wall mounting 1440 RPM without speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable for230/250 Volts single phase, 50 cycles A.C. supply, with one metre of 3core lead wire and with moisture proof treatment to winding and with ‗E‘ class insulation.(2-12-5)
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected in an approved manner.(2-12-14)
Supplying and erecting Five Star Rated Energy Saving Ceiling Fan230 V A.C. 50 cycles 1200 mm complete erected in position as per specifcation no.FG-FN/CF(2-12-21)
Supplying and erecting fan hook box of 10 mm M.S. round barbounded to the R.C.C. bars upto 50 mm length each side andpierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia.or equivalent square size and having depth upto 75 mm completeerected with duly painted by one coat of red oxide paint and two coatsof paint erected in position and without any leakage of slurry of cementconcrete on either side of the box and positioned to the bottom level ofthe slab.(2-13-5)
Supplying and erecting „B‟ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.(2-13-6)
Supplying & erecting 20 SWG G.I sheet metal cawl rectangular / round shaped with 25 x 25x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 300 mm as per specification no FG-FAS/MSC(2-13-17)
Supplying and erecting storage type horizontal / vertical water heater 15 litres capacity with BEE 5 star rating high impact resistance engineering plastic body on wall / loft complete duly tested and marking sr. no. and date of erection. specification no. AP-WH/STWH (3-1-1)
Supplying, erecting, testing and commissioning self-contained water cooler 230/250V 50 cycles nominal cooling capacity of 40 litres/hr and storage capacity 80 litres with partially stainless steel body complete. specification no. APWCR/ WC (3-3-3)
Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 2 litre/min. with activated carbon filter and softener operating on 230 V single phase AC supply. (3-5-2)
Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB.(5-3-2)
Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification No. SW-SWR/MCB.(5-3-3)
Supplying, erecting & marking DPMCB 6A to 32A, C- series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB (5-3-6)
Supplying, erecting & marking TPMCB 6 A to 32A in provided distribution board as per specification no. SW-SWR/MCB(5-3-14)
Supplying, erecting & marking TPMCB 40A to 63A in provided distribution board as per specification no. SW-SWR/MCB.(5-3-15)
Supplying, erecting & marking FPMCB 40A to 63A in provided distribution board as per specification no. SW-SWR/MCB.(5-3-17)
Supplying and erecting triple pole and neutral distribution board (TPNDB) surface/ flush mounted suitable for SPMCB of 12 ways on iron / GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB (5-4-1)
Supplying and erecting triple pole and neutral distribution board (TPNDB) surface/ flush mounted suitable for SPMCB of 24 poles on iron / GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB(5-4-2)
Supplying and erecting triple pole and neutral distribution board (TPNDB) surface/ flush mounted suitable for SPMCB of 36 poles on iron /GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB (5-4-3)
Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted SP / TP MCBs of 12 poles/ 4 ways, on iron/ GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB(5-4-10)
Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted SP / TP MCBs of 24 ways on iron/ GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB (5-4-11)
Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted SP / TP MCBs of 36 ways on iron/ GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB (5-4-12)
Supplying and erecting single pole and neutral distribution board (SPNDB) surface/flush mounted with 2 ways for incoming and 10 ways for outgoing SP MCB’s on iron/ GI frame as per specification no. SW-SWR/MCBDB (5-4-16)
Supplying and erecting single pole and neutral distribution board (SPNDB) with door surface/flush mounted with 2 ways for incoming and 2 ways for outgoing SP MCB’s on iron/ GI frame as per specification no. SW-SWR/MCBDB (5-4-17)
Supplying and erecting single pole and neutral distribution board (SPNDB) with door surface/flush mounted with 2 poles for incoming and 6 poles for outgoing SP MCB‟s on iron/ GI frame as per specification no. SW-SWR/MCBDB(5-4-18)
Providing, erecting and commissioning 2 pole RCCB only of electromagnetic type with 30/100/300 mA sensitivity and having capacity of 40A complete as per specification no. SW-RCCB/RCCB (5-6-2)
Providing, erecting and commissioning 4 pole RCCB only of electromagnetic type with 30/100/300 mA sensitivity and having capacity of 16/25A complete as per specification no. SW-RCCB/RCCB (5-6-4)
Providing, erecting and commissioning 4 pole RCCB only of electromagnetic type with 30/100/300 mA sensitivity and having capacity of 40A complete as per specification no. SW-RCCB/RCCB. (5-6-5)
Supplying, erecting & terminating XLPE armoured cable 4 core 6 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU. (7-2-32)
Providing & erecting Hot dipped galvanized ladder type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 150 mm width & 100 mm height comprising all required standard accessories.(7-11-1)
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 200 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.(7-11-7)
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.(7-11-8)
Providing & erecting Hot dipped galvanized cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) GI sheet of 200 mm width & 20 mm height complete with necessary hardware in approved manner.(7-11-12)
Providing & erecting Hot dipped galvanized cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) GI sheet of 300 mm width & 20 mm height complete with necessary hardware in approved manner.(7-11-13)
Supply Installation, testing and commissioning of Following Panels. Panels shall be fabricated out of 16 SWG CRCA sheet steel, with necessory structural supports in form of structural steel sections. Panels shall be floor mounted.The panel shall be compartmental type with suitable size of bus bar and separate cable and busbarchambers. The cable chambers shall be free from any live open connections. Multifuction meters for all incoming feeders, Indication lamps for all incoming and outgoing feeders for phase identifications and for indication of Switch status. METER PANEL - (TYPE II -16 buildings & TYPE III -1 building) INCOMER : 100 A FP MCCB Feeder- 1 Nos. 100 A FP MCCB Spreader Link - 1 Nos. Indicating 240V AC ON - 3 Nos. Outgoing Section 40A DP MCB - 12 Nos. 63A FP MCB - 1 Nos.
Supply Installation, testing and commissioning of Following Panels. Panels shall be fabricated out of 16 SWG CRCA sheet steel, with necessory structural supports in form of structural steel sections. Panels shall be floor mounted.The panel shall be compartmental type with suitable size of bus bar and separate cable and busbarchambers. The cable chambers shall be free from any live open connections. Multifuction meters for all incoming feeders, Indication lamps for all incoming and outgoing feeders for phase identifications and for indication of Switch status. METER PANEL SHOPPING CENTER INCOMER : 63 A FP MCB - 1 Nos. 2 A SP MCB - 1 Nos. Indicating 240V AC ON - 3 Nos. Outgoing Section 40A DP MCB - 6 Nos.
Supply Installation, testing and commissioning of Following Panels. Panels shall be fabricated out of 16 SWG CRCA sheet steel, with necessory structural supports in form of structural steel sections. Panels shall be floor mounted.The panel shall be compartmental type with suitable size of bus bar and separate cable and busbarchambers. The cable chambers shall be free from any live open connections. Multifuction meters for all incoming feeders, Indication lamps for all incoming and outgoing feeders for phase identifications and for indication of Switch status. CYBER POLICE STATION MAIN LT PANEL 1 INCOMER : 160 A FP MCCB - 1 Nos. 160 A MCCB SPRADER LINK 1 Nos. Indicating lamp 240V AC R/Y/B - 3 Nos. Indicating lamp 240V AC On/Off/trip - 3 Nos. 2A SP MCB - 1 Nos. Outgoing Section 40 A FP MCB Feeder - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 40 A FP MCB Feeder - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 63 A FP MCB Feeder - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 63 A FP MCB Feeder - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 63 A FP MCB Feeder - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 63 A FP MCB Feeder - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 63 A FP MCB Feeder - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 63 A FP MCB Feeder - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos.
Supply Installation, testing and commissioning of Following Panels. Panels shall be fabricated out of 16 SWG CRCA sheet steel, with necessory structural supports in form of structural steel sections. Panels shall be floor mounted.The panel shall be compartmental type with suitable size of bus bar and separate cable and busbarchambers. The cable chambers shall be free from any live open connections. Multifuction meters for all incoming feeders, Indication lamps for all incoming and outgoing feeders for phase identifications and for indication of Switch status. ADMIN BUILDING MAIN LT PANEL 1 INCOMER : 200 A FP MCCB - 1 Nos. 200 A MCCB SPRADER LINK 1 Nos. Indicating lamp 240V AC R/Y/B - 3 Nos. Indicating lamp 240V AC On/Off/trip - 3 Nos. 2A SP MCB - 1 Nos. Outgoing Section 40 A FP MCB Feeder - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 40 A FP MCB Feeder - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 63 A FP MCB Feeder - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 63 A FP MCB Feeder - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 63 A FP MCB Feeder - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 63 A FP MCB Feeder - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 63 A FP MCB Feeder - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 100 A FP MCCB Feeder - 1 Nos. 100 A FP MCCB SPREADER LINK 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos.
Supply Installation, testing and commissioning of Following Panels. Panels shall be fabricated out of 16 SWG CRCA sheet steel, with necessory structural supports in form of structural steel sections. Panels shall be floor mounted.The panel shall be compartmental type with suitable size of bus bar and separate cable and busbarchambers. The cable chambers shall be free from any live open connections. Multifuction meters for all incoming feeders, Indication lamps for all incoming and outgoing feeders for phase identifications and for indication of Switch status. MT WORKSHOP INCOMER : 200 A FP MCCB Feeder - 1 Nos. 200 A FP MCCB SPREADER LINK -1 Nos. CT 200/5A, 10VA, CL0.5 MULTIFUNCTION METER Indicating lamp 240V AC R/Y/B - 3 Nos. Indicating lamp 240V AC On/Off/trip -3 Nos. Outgoing Section 100 A FP MCCB Feeder - 1 Nos. 100 A FP MCCB SPREADER LINK - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 100 A FP MCCB Feeder - 1 Nos. 100 A FP MCCB SPREADER LINK - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 100 A FP MCCB Feeder - 1 Nos. 100 A FP MCCB SPREADER LINK - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 100 A FP MCCB Feeder - 1 Nos. 100 A FP MCCB SPREADER LINK - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 63 A FP MCB Feeder - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 63 A FP MCB Feeder - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 63 A FP MCB Feeder - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 40 A FP MCB Feeder - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos.
Supplying & laying HMS PVC conduit 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. (1-1-8)
Supplying & erecting HMS PVC conduit 25 mm. dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.(1-1-9)
Supplying and erecting modular type T.V. socket single outlet ISI mark approved make duly erected on provided plate and box with wiring connections complete.(1-8-14)
Supplying and erecting modular type telephone socket one gang with safety shutter ISI mark approved make duly erected on provided plate and box with wiring connections complete. (1-8-15)
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.(1-8-34)
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.(1-8-35)
Supplying & erecting telephone copper cable 2 pair with 0.5 mm dia. laid in provided PVC casing capping/ conduit as per specification No. WG-TW(1-10-1)
Supplying & erecting jelly filled armoured telephone copper cable 10 pair with 0.5 mm dia. laid in provided trench as per specification No. WG-TW (1-10-13)
Supplying & erecting jelly filled armoured telephone copper cable 20 pair with 0.5 mm dia. laid in provided trench as per specification No. WG-TW (1-10-14)
Supplying & erecting jelly filled armoured telephone copper cable 50 pair with 0.5 mm dia. laid in provided trench as per specification No. WG-TW (1-10-15)
Supplying & erecting jelly filled armoured telephone copper cable 100 pair with 0.5 mm dia. laid in provided trench as per specification No. WG-TW (1-10-16)
Supplying & installing co-axial copper cable low voltage grade RG-6 as per specification No. WG-TW(1-10-19)
Supplying, erecting & commissioning Main Distribution Frame (MDF) Box 50x50 pairs as per specification No. WG-TW. (1-11-1)
Supplying, erecting & commissioning MDF Box 100 x 100 pairs as per specification No. WG-TW (1-11-3)
Supplying, erecting & commissioning MDF Box 150 x 150 pairsas per specification No. WG-TW (1-11-4)
Supplying, erecting & commissioning junction box suitable for 10 pairs as per specification No. WG-TW (1-11-12)
Supplying, erecting & commissioning junction box suitable for 20 pairs as per specification No. WG-TW (1-11-13)
Supplying, erecting & commissioning junction box suitable for 30 pairs as per specification No. WG-TW (1-11-14)
Supplying, erecting & commissioning junction box suitable for 40 pairs as per specification No. WG-TW (1-11-15)
Supplying, erecting & commissioning junction box suitable for 50 pairs as per specification No. WG-TW (1-11-16)
Supplying, erecting & commissioning junction box suitable for 100 pairs as per specification No. WG-TW (1-11-18)
Supplying, erecting & commissioning 10 pair module for connection & disconnection of telephone cable as per specification No. WG-TW (1-11-20)
Supplying, installing, testing & commissioning digital (hybrid) type EPABX of 6 x 16 extensions complete.(1-11-27)
Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of 6 x 24 extensions suitable upto 96 extensions complete.(1-11-28)
Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of 6 x 24 extensions suitable upto 96 extensions complete. (NOTE - 53731+(31576*2) = 116883*5% = 122727.15 for card = 24+(16*2)= 56 (1-11-28)
Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of 6 x 24 extensions suitable upto 96 extensions complete. (NOTE - 53731+(31576*6) = 243187*5% = 255346.35 for card = 24+(16*6)= 120 (1-11-28)
Supplying, installing, testing & commissioning push button telephone instrument desk top/wall mount unit as per specification complete (1-11-30)
Supplying, installing, testing & commissioning push button telephone instrument desk top/wall mount with caller ID unit as per specification complete. (1-11-31)
Supplying, installing, testing & commissioning approved type Digital key telephone / IP telephone instrument as per specification complete. (1-11-32)
Supplying & installing UTP networking cat-6 cable suitable for LAN / WAN Computer net-working as per specification No. WG-COC/NC (1-12-1)
Supplying and fixing 1 meter length, UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC (1-12-8)
Supplying and fixing 3 meter length, UTP Patch cord of Cat 6 type in position as per specification No. WG-COC/PC (1-12-9)
Supplying, fixing, and configuring ethernet managed ethernet switch of 24 ports with 2 SFP + 2 combo port and web view/CLI on provided rack or as directed as per specification no. WG-NWC/GBS (1-13-4)
Supplying and fixing tool-less Information Outlet (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO (1-14-2)
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP (1-14-4)
Supplying and fixing 36 U rack for networking with necessary arrangement for fixing required 16A/6A switches & plugs for LAN network as per specification No. WG-NAS/RAK (1-14-17)
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 450x550x367 mm) as per specification No. WG-NAS/RAK (1-14-18)
Supplying & erecting on line UPS pure sine wave of 10 kVA capacity complete with standard features, along with necessary SMF batteries for 30 mins battery backup, as per specification no. AP-UPS (3-7-7)
Providing Supplying, & fixing of EPSON Make 3LCD Projector with 3300 lmns, HDMI, USB, VGA Ports. Bright high-quality images with easy to use XGA model, featuring 3LCD technology. Resolution 1024 x 768, Contrast Ratio 15000:1, Throw Ratio 1.44 - 1.95:1, Video Color modes : Blackboard, Cinema, Dynamic, Presentation, sRGB. 2 Watt inbuilt loudspeaker. Weight 2.4kg. Colour reproduction upto 1.07 billion colours, Aspect ratio 4:3. (non csr)
Providing Supplying, & fixing of ceiling mount kit Heavy Quality, adjustable with -/+ 15' Tilting. 2feet x 2feet to fit EPSON Make 3LCD Projector, adjustable bracket (non csr)
Providing Supplying, & fixing of Motorized 4 x6 mat finish screen with 2” black border, Seamless compound multi-layers diffuse reflection fabric. Tubular Motor with smooth & quieter operation. Casing High strength alloy aluminium roller, screen fabric rod adjustment for wrinkle free & improved fabric stiffness. (non csr)
Providing & erecting 4 Pole MCCB upto 100A, 415V, with short circuit rating 25 kA (Ics=100% of Icu ),adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB(5-5-1) - with note 1
Providing & erecting 4 Pole MCCB of 250A,415V capacity with short circuit rating 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB (5-5-3) - with note 1
Providing & erecting 4 Pole MCCB of 315/400A, 415V capacity with short circuit rating 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosureon iron /GI frame as per specification no. SW-SWR/MCCB(5-5-4) - with note 1
Providing & erecting floor / wall mounting, MCCB panel board with door suitable for four pole incoming 250A, 4 ways four pole outgoing upto 100 A MCCB's on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCB'S)(5-7-2)
Providing & erecting floor / wall mounting, MCCB panel board with door suitable for four pole incoming 400A, 4 ways four pole outgoing upto 100 A MCCB's on provided iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCB'S)(5-7-7)
Supplying , erecting, testing & commissioning SF 6 Insulated 22kV, 630A, 16kA/3sec, 2 way outdoor, extensible motorised SCADA compatible RMU as per electric supply company specification consisting of 1 no. feeder with load break switch and 1 no. feeder with VCB as per specification no. SW-HTS / RMU SCADA (1LBS +1VCB) (5-9-24)
Supplying , erecting, testing & commissioning SF 6 Insulated 22kV, 630A, 16kA/3sec, 5 way outdoor, extensible motorised SCADA compatible RMU as per electric supply company specification consisting of 2 nos. feeder with load break switch and 3 nos. feeder with VCB. as per specification no. SW-HTS / RMU SCADA. (2LBS +3VCB+M) (5-9-27)
Supplying, erecting, testing, commissioning 22 KV HT metering cubical (compact type) approved by MSEDCL/licensee fabricated with 2mm.(14 SWG) M.S. sheets with supporting angle and channel, painted with powder coating / epoxy paint of required shade copper bus bar size 25x6 mm electronic security lock and heavy duty mechanical lock, with counter meter for measuring no of times the opening of doors, top side cover ( CT,PT cover) interlock with meter doors, epoxy coated 3 nos CT having required ratio between 50/5 A to 100/5 A, VA10, class 0.2S, 22000/V3/110/V3 VA 50, class 0.2 epoxy terminal block suitable for provided trivector meter, and provision for incoming and outgoing cables etc. complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation ( 6-4-4)
Supplying, erecting & terminating XLPE armoured cable 3½ core 25 sq mm aluminium conductor with continuous 5.48 sq mm (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL( 7-1-15)
Supplying, erecting & terminating XLPE armoured cable 3½ core 50 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL(7-1-17)
Supplying, erecting & terminating PVC armoured cable 3½ core 70 sq mm aluminium conductor with continuous 8.35 sq mm (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (7-1-18)
Supplying, erecting & terminating PVC armoured cable 3½ core 95 sq mm aluminium conductor with continuous 8.35 sq mm (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL(7-1-19)
Supplying, erecting & terminating XLPE armoured cable 3½ core 120 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL(7-1-20)
Supplying, erecting & terminating XLPE armoured cable 3½ core 150 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL(7-1-20)
Supplying, erecting & terminating XLPE armoured cable 1100 V. 3½ core 185 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL(7-1-22)
Supplying, erecting & terminating XLPE armoured cable 3½core 240 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL(7-1-23)
Supplying , erecting & terminating 3 x 95 sq. mm. aluminium 22 kV(E), XLPE armoured cable on wall/ceiling or laid in provided trench / pipe in an approved manner as per specification no.CB-HT(7-3-17)
Supplying , erecting & terminating 3 x 300 sq. mm. aluminium 22 kV(E), XLPE armoured cable on wall/ceiling or laid in provided trench / pipe in an approved manner as per specification no. CB-HT (7-3-22)
Providing and erecting Heat shrinkable indoor termination kit for 11 kV (UE)/22 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. with necessary material as per specification no. CB-JT/HT(7-5-12)
Providing and erecting Heat shrinkable outdoor termination kit for 11 kV (UE)/ 22 kV ( E ) XLPE HT cable 3x240 to 400 sq. mm. with necessary material as per specification no. CB-JT/HT (7-5-16)
Providing and erecting Heat shrinkable outdoor termination kit for 11 kV (UE)/ 22 kV ( E ) XLPE HT cable 3x240 to 400 sq. mm. with necessary material as per specification no. CB-JT/HT (7-5-17)
Supplying & erecting G.I. pipe „A‟ class 75 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE(7-6-4)
Supplying & laying (including excavation) 15 cm dia RCC Hume pipe with coupling collar of standard thickness at required depth up to 90 cm below road / ground surface, for enclosing provided cable & necessary back filling with light ramming to make the road/ground surface as it was (Except bitumen carpet).(7-6-5)
Supplying & laying (including excavation)25 cm dia RCC Hume pipe of standard thickness at required depth up to 90 cms. below road / ground surface, for covering provided cable & necessary back filling with light ramming to make the road/ground surface as it was (Except bitumen carpet).(7-6-7)
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.(7-6-16)
Supplying and erecting rolled steel joist (girder) pole 100 x 116 mm (23 kg/m) with provided base plate in provided foundation as per specification no. OH-PL/RSJ(8-1-12) ( For 0.5 Km No of Pole 9 Nos ,Each Pole of 11 Mtr so total Length 11x9= 99)
Supplying & erecting MS pole bracket, for OH conductor fabricated from ISM channel, 75x40x6mm 1100mm long for 4 insulators and erecting on pole with 50x6 mm clamp as per approved method of construction and complete as per specification no. OH-PL/BKT(8-4-8)
Supplying and erecting ACSR conductor of size - 6/1-4.72 mm (Dog) complete. (394 kg/km) as per specification no. OH?CON/ACSR(8-5-11)
Supplying and erecting porcelain disc type insulator with necessary hardware suitable for 22kV line, complete as per specification no. OH-INS/DI(8-6-7)
Supplying and erecting porcelain pin type insulator suitable for 22kV line with G.I. pin complete as per specification no. OH?INS/PN(8-6-9)
Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/10 SWG, G.l. stay rod 20 mm x 1.8 m length and pole clamps duly erected in provided cement concrete foundation.(8-7-1)
Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as per specification no. EA?EP(9-1-4)
Supply, Installation, Testing and commissioning of UL Certified / CPRI Tested Maintenance Free Earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron Molecular Copper Bonded Earthing Rod of Length 3m along with 25 kg Carbon Based environment friendly back fill Ground Enhancing compound required to fill up the excavated earth with required quantity as per specification no EA-MOBI(9-1-5)
Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in an approved manner with joints required. as per specification No (EA-EP).(9-2-2)
Supplying and erecting G.I. strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joint required. as per specification No (EA-EP). (9-2-3)
Supplying, installing, testing & commissioning 3 phase, 22/0.433 kV, 50 Hz., 315 kVA, oil immersed and naturally cooled indoor type, copper wound transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40oC by thermometer in oil and 45oC by the resistance in winding at full load rating, with HV tapping (with off load tap changer) off Load +5 to -10 in steps of 2.5%, with standard accessories complete with test certificate with losses below 1077 Watts at 50% load, 3255 Watts at 100% load as per IS:1180 - 2014 energy efficiency level II with necessary permissions of Electrical Inspector, as per specification no SS- TR. (10-1-15) -with note 1
Supplying, installing, testing & commissioning 3 phase, 22/0.433 kV, 50 Hz., 630 kVA, oil immersed and naturally cooled indoor type, copper wound transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40oC by thermometer in oil and 45oC by the resistance in winding at full load rating, with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5%, with standard accessories complete with test certificate with losses below 1953 Watts at 50% load, 5565 Watts at 100% load as per IS:1180 - 2014 energy efficiency level II with necessary permissions of Electrical Inspector, as per specification no SS- TR.(10-1-17) -with note 1
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.(10-2-22)
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working upto 22 kV supply complete.(10-2-23)
Supplying and erecting anti climbing devices, fabricated from pole clamps of MS Flat 40x5 mm, with drooping spikes 15 cm. in length, welded to it and erected on pole.(10-2-17)
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes) (10-2-27)
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class C insulation conforming to IS: 15652 – 2006 & CPRI tested having 3mm thickness upto 33 kV(10-2-30)
Supplying shock proof leather safety shoes of electrical grade of standard size as IS :11226, 14544 duly tested, with necessary test certificate from manufacturer.(10-2-31)
Making cement concrete foundation including excavation (60 x 60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. (for above 9 m poles) (16-3-4)
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay).(16-3-6)
Supply Installation, testing and commissioning of Following Panels. Panels shall be fabricated out of 16 SWG CRCA sheet steel, with necessory structural supports in form of structural steel sections. Panels shall be floor mounted.The panel shall be compartmental type with suitable size of bus bar and separate cable and busbarchambers. The cable chambers shall be free from any live open connections. Multifuction meters for all incoming feeders, Indication lamps for all incoming and outgoing feeders for phase identifications and for indication of Switch status. MAIN LT PANEL 1 INCOMER : 1000 A FP ACB - 1 Nos. Surge Protection device TPN Class B- 1 Nos. CT 1000A/5A 10 VA Cl 0.5 - 3 Nos. Indicating lamp 240V AC R/Y/B - 3 Nos. Indicating lamp 240V AC On/Off/trip - 3 Nos. Multifunction meter - 1 Nos. 2A SP MCB - 1 Nos. Outgoing Section 315 A FP MCCB Feeder - 1 Nos. 315 A MCCB SPREADER LINK - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 315 A FP MCCB Feeder - 1 Nos. 315 A MCCB SPREADER LINK - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 315 A FP MCCB Feeder - 1 Nos. 315 A MCCB SPREADER LINK - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 315 A FP MCCB Feeder - 1 Nos. 315 A MCCB SPREADER LINK - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 250 A FP MCCB Feeder - 1 Nos. 250 A MCCB SPREADER LINK - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 315 A FP MCCB Feeder - 1 Nos. 315 A MCCB SPREADER LINK - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos.
Supply Installation, testing and commissioning of Following Panels. Panels shall be fabricated out of 16 SWG CRCA sheet steel, with necessory structural supports in form of structural steel sections. Panels shall be floor mounted.The panel shall be compartmental type with suitable size of bus bar and separate cable and busbarchambers. The cable chambers shall be free from any live open connections. Multifuction meters for all incoming feeders, Indication lamps for all incoming and outgoing feeders for phase identifications and for indication of Switch status. MAIN LT PANEL 2 INCOMER : 630 A FP MCCB Feeder - 1 Nos. 630 A FP MCCB SPREADER LINK -1 Nos. Surge Protection device TPN Class B -1 Nos. CT 500/5A 10 VA Cl 0.5 - 3 Nos. Indicating lamp 240V AC R/Y/B - 3 Nos. Indicating lamp 240V AC On/Off/trip -3 Nos. Multifunction meter - 1 Nos. 2A SP MCB - 1 Nos. Outgoing Section 315 A FP MCCB Feeder - 1 Nos. 315 A FP MCCB SPREADER LINK - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 315 A FP MCCB Feeder - 1 Nos. 315 A MCCB SPREADER LINK - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 250 A FP MCCB Feeder - 1 Nos. 250 A FP MCCB SPREADER LINK- 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 250 A FP MCCB Feeder - 1 Nos. 250 A FP MCCB SPREADER LINK- 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos.
Supply Installation, testing and commissioning of Following Panels. Panels shall be fabricated out of 16 SWG CRCA sheet steel, with necessory structural supports in form of structural steel sections. Panels shall be floor mounted.The panel shall be compartmental type with suitable size of bus bar and separate cable and busbarchambers. The cable chambers shall be free from any live open connections. Multifuction meters for all incoming feeders, Indication lamps for all incoming and outgoing feeders for phase identifications and for indication of Switch status. MAIN LT PANEL 3 INCOMER : 1000 A FP ACB - 1 Nos. Surge Protection device TPN Class B- 1 Nos. CT 1000A/5A 10 VA Cl 0.5 - 3 Nos. Indicating lamp 240V AC R/Y/B - 3 Nos. Indicating lamp 240V AC On/Off/trip - 3 Nos. Multifunction meter - 1 Nos. 2A SP MCB - 1 Nos. Outgoing Section 500 A FP MCCB Feeder - 1 Nos. 500 A FP MCCB SPREADER LINK - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 315 A FP MCCB Feeder - 1 Nos. 315 A MCCB SPREADER LINK - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 315 A FP MCCB Feeder - 1 Nos. 315 A MCCB SPREADER LINK - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 200 A FP MCCB Feeder - 1 Nos. 200 A MCCB SPREADER LINK - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 125 A FP MCCB Feeder - 1 Nos. 125 A MCCB SPREADER LINK - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 100 A FP MCCB Feeder - 1 Nos. 100 A MCCB SPREADER LINK - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 100 A FP MCCB Feeder - 1 Nos. 100 A MCCB SPREADER LINK - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 100 A FP MCCB Feeder - 1 Nos. 100 A MCCB SPREADER LINK - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos.
Supply Installation, testing and commissioning of Following Panels. Panels shall be fabricated out of 16 SWG CRCA sheet steel, with necessory structural supports in form of structural steel sections. Panels shall be floor mounted.The panel shall be compartmental type with suitable size of bus bar and separate cable and busbarchambers. The cable chambers shall be free from any live open connections. Multifuction meters for all incoming feeders, Indication lamps for all incoming and outgoing feeders for phase identifications and for indication of Switch status. FEEDER PILLAR 1 INCOMER : 500 A FP MCCB Feeder - 1 Nos. 500 A FP MCCB SPREADER LINK -1 Nos. Indicating lamp 240V AC R/Y/B - 3 Nos. Indicating lamp 240V AC On/Off/trip -3 Nos. Outgoing Section 200 A FP MCCB Feeder - 1 Nos. 200 A FP MCCB SPREADER LINK - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 200 A FP MCCB Feeder - 1 Nos. 200 A FP MCCB SPREADER LINK - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 63 A FP MCB Feeder - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 63 A FP MCB Feeder - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos.
Supply Installation, testing and commissioning of Following Panels. Panels shall be fabricated out of 16 SWG CRCA sheet steel, with necessory structural supports in form of structural steel sections. Panels shall be floor mounted.The panel shall be compartmental type with suitable size of bus bar and separate cable and busbarchambers. The cable chambers shall be free from any live open connections. Multifuction meters for all incoming feeders, Indication lamps for all incoming and outgoing feeders for phase identifications and for indication of Switch status. DG PANEL 1 INCOMER : 200 A FP MCCB Feeder - 1 Nos. 200 A FP MCCB SPREADER LINK -1 Nos. CT 200/5A, 10VA, CL0.5 MULTIFUNCTION METER Indicating lamp 240V AC R/Y/B - 3 Nos. Indicating lamp 240V AC On/Off/trip -3 Nos. Outgoing Section 100 A FP MCCB Feeder - 1 Nos. 100 A FP MCCB SPREADER LINK - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 100 A FP MCCB Feeder - 1 Nos. 100 A FP MCCB SPREADER LINK - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 63 A FP MCB Feeder - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos. 63 A FP MCB Feeder - 1 Nos. Indicating Lamp 240 V AC ON - 1 Nos.
Supplying & erecting HMS P.V.C. conduit 25 mm. dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. (1-1-9)
Supplying, erecting & terminating XLPE armoured cable 3½ core 95 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL(7-1-19)
Supplying, erecting & terminating XLPE armoured cable 4 core 4 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU (7-2-31)
Supplying, erecting & terminating XLPE armoured cable 4 core 10 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU (7-2-33)
Supplying and installing air vessel of 300 MM dia 1.5M in height M.S. tank installed inside puMp house / on terrace coMplete as per specification no. FF-FFA/ACT(7-11-11)
Providing Round bottom fire bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete.
Providing Floor Mounting stand for keeping 4 Nos. of FIRE buckets 1500MM in length, 900MM in height fraMe Made out of 30x30x4 MM angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint coMplete.(10-2-25)
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conforM to IS 2878 /15683 coMplete erected with necessary claMp Made froM 50 x 6 MM. M. S. flat with nut & bolts grouted in wall complete.(10-2-34)
Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary claMp for erection on wall.(10-2-36 )
Supplying and erecting D.O.L. Starter 400V. 3 phase, 50 cycles with no volt coil and overload element with necessary materials and connected to supply upto 7.5 H.P. (12-4-2)
Supplying, installing, testing and commissioning with perfect aligning, proper levelling of fire service main single stage pump, of 1800 LPM at 50 m head centrifugal type, 50 HP (37 kW), 3 phase, 415 volt, 50Hz or of suitable HP complete as per specification no. FF-MFP/SSC(13-1-2)
Supplying, installing, testing and commissioning with perfect aligning, proper levelling of jockey pump of 240 LPM at 56 m head, 15 HP (11 kW), 3 phase, 415 volt, 50Hz or of suitable HP with suitable stages as per specification no. FF-MFP/JP (13-3-1)
Supplying, installing, testing and commissioning with perfect aligning, proper levelling of booster pump of 450 LPM at 35 m head 7.5 HP (5.5 KW), 3 phase, 415 volt, 50Hz or of suitable HP with suitable stages as per specification no. FF-MFP/BP (13-4-2)
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 25 MM dia with necessary fittings coMplete as perspecification no. FF-PP(13-5-2)
Supplying and erecting G.I.pipe above ground of ‘C’ class ERW of size 50 MM dia with necessary fittings as per specification No. FF-PP (13-5-3)
Supplying and erecting G.I.pipe above ground of ‘C’ class ERW of size 65 MM dia with necessary fittings as per specification No. FF-PP (13-5-4)
Supplying and erecting G.I. pipe above ground of „C‟ class ERW of size 75/80 MM dia with necessary fittings coMplete as per specification no. FF-PP(13-5-5)
Supplying and erecting G.I.pipe above ground of ‘C’ class ERW of size 100 MM dia with necessary fittings as per specification No. FF-PP (13-5-6)
Supplying and erecting G.I.pipe above ground of ‘C’ class ERW of size 150 MM dia with necessary fittings as per specification no. FF-PP (13-5-7)
Supplying and erecting G.I.pipe above ground of ‘C’ class ERW of size 200 MM dia with necessary fittings as per specification no. FF-PP (13-5-8)
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.
Supplying and erecting cast iron foot valve ball type/flap type of size 200 mm dia with strainer for negative suction complete as per specification no. FF-VL/FV (13-6-4)
Supplying and erecting 75/80 mm dia end line strainer for positive suction complete as per specification no. FF-VL/ELS (13-6-5)
Supplying & erecting cast iron double flange butterfly valve of size 50 MM dia. as per specification No. FF-VL/BFV (13-6-13)
Supplying & erecting cast iron double flange butterfly valve of size 65 MM dia. as per specification No. FF-VL/BFV(13-6-14)
Supplying & erecting cast iron double flange butterfly valve of size 75/80 MM dia. as per specification No. FF-VL/BFV (13-6-15)
Supplying & erecting cast iron double flange butterfly valve of size 100 MM dia. as per specification No. FF-VL/BFV (13-6-16)
Supplying & erecting cast iron double flange butterfly valve of size 150 MM dia. as per specification No. FF-VL/BFV (13-6-17)
Supplying & erecting cast iron double flange butterfly valve of size 200 MM dia. as per specification No. FF-VL/BFV (13-6-18)
Supplying and erecting double flange NRV of size 75/80 MM dia as per specification No. FF-VL/NRV (13-6-19)
Supplying and erecting double flange NRV of size 100 MM dia as per specification No. FF-VL/NRV (13-6-20)
Supplying and erecting double flange NRV of size 150 MM dia as per specification No. FF-VL/NRV (13-6-21)
Supplying and erecting double flange NRV of size 200 MM dia as per specification No. FF-VL/NRV (13-6-22)
Supplying and erecting gun metal single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV (13-6-30)
Supplying & installing one piece moulded HDPE / fibre water tank for negative suction only, having capacity 1000 litres fitted with necessary accessories complete as per specification no. FF-FFA/PT(13-7-1)
Supplying and installing wall Mounting swinging Hose reel druM fitted with 19 MM dia. 30M high pressure polypropylene (Polyhose) long fitted with necessary accessories coMplete as per specification No. FFFFA/HV (13-7-2 )
Supplying fire fighting (reinforced rubber lined) R.R.L. Hose pipe, 63MM dia,15M in length, fitted with necessary accessories coMplete as per specification no. FF-FFA/RRL(13-7-4)
Supplying gun Metal branch pipe of 63 MM dia fitted with 20 MM dia detachable hexagonal nozzle as per specification No. FF-FFA/NZ (13-7-7)
Supplying and erecting 2 Way fire brigade header (SiaMese Connection)of 150 MM dia for supplying water to wet riser systeM as per specification No. FF-FFA/SMC (13-7-11)
Supplying and erecting 20/25MM dia gun Metal air release cock,, with necessary G.I. coupling to be fitted on top of Air vessel or on wet riser as per specification No. FF-FFA/ARV (13-7-13)
Supplying and installing pressure gauge100 MM dia.,0-300 PSI or 0-14 kg per cM square fitted with 12/15 MM Ø. pad cock valve, and G.I. pipe, elbow etc. as per requireMent in an approved Manner as per specification No. FF-FFA/PG (13-7-14)
Supplying and installing pressure switch with 12/15 MM Ø isolation valve, G.I. nipple, elbow etc. in an approved Manner as per specification No. FF-FFA/PS (13-7-15)
Supplying and erecting M.S./CRCA cabinet for housing Fire Brigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8" x 6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour..(13-7-19)
Supplying, installing, testing and commissioning optical type smoke detector complete on box as per specification no. FFFAS/ SD(13-8-2 )
Supplying, erecting, testing and coMMissioning Manual Call Point (Pill box) (Addressable) with break glass push button in Metal enclosure coMplete as per specification No. FF-FAAS/MCP ( 13-8-5)
Supply and erecting hooters with CRCA enclosure coMplete as per specification No. FF-FAAS/HTR (13-8-6)
Supplying and erecting XLPE arMoured cable 2 core 1.5 sq.MM. copper conductor coMplete erected on wall/ ceiling as per specification No. CB-LT/CU for FAS system (13-8-8)
Supplying, installing, testing and commissioning of 2 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories complete as per specification no. FF-FAAS/FACP(13-8-12)
Supplying, installing, testing and commissioning of 4 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories complete as per specification no. FF-FAAS/FACP(13-8-12) - with note 1
Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete (16-1-5)
Supplying and installing of Horizontally split Case type centrifugal double Suction long Coupled base mounted Single stage pump Engine driven split case in Cast iron bronze fitted construction Specifically designed for quiert operation. Diesel Engine water cooled( heat exchanger) type and complete with accessories including auto start control panel batteries as per Specification. Rate also shall be inclusive Of Pressure relief vaive and double walled Diesel tank of rated Capacity Engine Exhaust pipe insulation.The impeller shaft shall be a Solid stainless steel shaft. Pump shall be equiped with in direct contact with the pump shaft. Impeller shall be of enclosed duble suction type made of bronze both hydraulically and dynamically balanced keyed to the shaft and fixed in axial position. Engine shall meet scheduled horsepower speed voltage and enclosure design. Pump and Engine shall be factory aligned and shall be realigned after installation by the manufacturer's representative. Flow rate:1800 LPM at 70 m Head 60 HP (45 KW ). 2960 RPM. (NON-CSR)
Supplying nd errecting automatic control panel for 50HP centrifugal type main pump and 15 HP/20 HP jockey pump set consisiting L&T control switchgear of suitable rating star delta starter S.P.P. dry run water level controller ammeter voltmeter phase indicating lamp MCCB 200A TP extended rotary drive spreader link. MCB 6A CT wire wound 5VA MCCB 100A TP contactor for 50HP motor OLR 100A. Star delta timer MCB 2A FPMCCB 63A power contactor for 15HP motor OLR 12.5A MCCB 160A TP aluminium busbar with support sleeves other hardware name plate door lock etc.
Supplying & erecting HMS P.V.C. conduit 25 mm. dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. (1-1-9)
Supplying, installing, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1.5 TR capacity having ISEER minimum 4.50 suitable to operate on250V, 50 cycles, A.C. supply having 1 no of air handling unit hiwall / floor mounting type complete with refrigerant R410 A/R32 and copper condensor at position. specification no.APAC/ SAC (3-2-9)
Supplying, installing, testing and commissioning split type variable speed inverter technology room Airconditioning unit 1 TR capacity having ISEER minimum 3.50 to maximum 3.99 suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall mounting type complete with refrigerant R410A/R32 and copper condensor at position. specification no.APAC/ SAC (3-2-10)
Supplying & erecting soft drawn copper pipe suitable for refrigeration system having 22 SWG thickness and inner dia / size 12 mm complete. (3-2-15)
Supplying & erecting soft drawn copper pipe suitable for refrigeration system having 22 SWG thickness and inner dia / size 16 mm complete. (3-2-16)
Supplying & erecting soft drawn copper pipe suitable for refrigeration system having 22 SWG thickness and inner dia / size 32 mm complete.(3-2-18)
Supplying, installing, testing and commissioning cassette type split room air conditioning unit 1.5 TR having ISEER minimum 4.50 suitable for capacity 230/250 V, 50 cycles, AC supply having 1 no. air handling unit false ceiling mounting type complete with refrigerant R32/R410A and copper condenser coil at position with provided copper piping and drainage pipe.(3-2-21)
Supplying, installing, testing and commissioning cassette type variable speed inverter technology split room air conditioning unit 3 TR capacity having ISEER maximum 4.50, suitable to operate on 230V /415 V, 50 cycles, AC supply having 1 no. air handling unit false ceiling mounting type complete with refrigerant R32/R410A & copper condenser coil at position with provided copper piping and drainage pipe. (3-2-23)
Carrying out core cutting of size 3" to 5" dia x 15" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original(3-11-77)
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for over coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 12 mm for solar water heater system. (4-2-15)
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for over coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 16 mm for solar water heater system. (4-2-16)
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for over coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 32 mm for solar water heater system. (4-2-20)
Supplying & laying HMS PVC conduit 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. (1-1-8)
Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 modules duly erected. (1-8-29)
Supplying & installing HDMI cable low voltage grade as per specification as per specifications having 10 mtr cord length with male/female 19pin HDMI connectors as per requirements complete. (1-10-23)
Supplying & installing HDMI cable low voltage grade as per specification as per specifications having 20 mtr cord length with male/female 19pin HDMI connectors as per requirements complete. (1-10-25)
Supplying & installing UTP networking cat-6 cable suitable for LAN / WAN Computer net-working as per specification No. WG-COC/NC (1-12-1)
Supplying and erecting FR grade, pvc armoured multimode armoured multimode optical fibre cable with 6 fibres, with core dia 50/125 µm (OM3) suitable for 1 gbps ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification No. WG-COC/OFC LSZH (1-12-10)
Supplying, fixing, and configuring web smart power over ethernet switch of 24 ports on provided rack or as directed as per specification No. WG-NWC/ENS (1-13-1)
Supplying, fixing, and configuring 1-port mini-GBIC SX mutli-mode fibre transceiver (up to 550m, support 3.3V power) as per specification complete. (1-13-9)
Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. (1-14-1)
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 450x550x367 mm) as per specification No. WG-NAS/RAK (1-14-18)
Supplying & installing single mode fibre patch cord 3 m – duplex complete. (1-14-49)
Supplying and fixing IP66 enclosure for fibre splicing as per specification complete. (1-14-52)
Supplying & erecting on line UPS pure sine wave of 1 kVA capacity complete with standard features, along with necessary SMF batteries for 30 mins. battery backup, as per specification no. AP-UPS (3-7-1)
Supply installation commisioning of 3 MP full HD IP Bullet Camera VIDEO COMPRESSION H.265+/H.265+/H.264+/H.264 VIDEO Resolution 2688 x 1520 resolution, Frame Rate - upto 25-30fps, Image Sensor - 1/3"4 MP progressive scan imager, Lens type - Fixed local , Zoom lens - 2.8 mm, F2.0, Minium illumination - 0.08 lux color @ F2.0(Color 1/3s , 30 IRE) 0 lux B/W with IR LEDs on @ F2.0, Image Setting - Compression , color, Brightnrdd, sharpness, contrast, white balance, exposure control,blacklight, compensation protocol - IPv4/v6, TCP/IP, UDP, RTP, RTSP, RTCP, HTTP, HTTPS, SSL, FTP, SMTP, DHCP,PPPoE, UPnP, SNMP v2/v3, Bonjour, DNS, DDNS, IEEE 802 1X , Qos, NTP, Security - User account and password protection, HTTPS, IP Filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES-256, SSH/Telnet closed FTP Disable Operation Conditions - 30 ºC to 60 ºC Casing/ Housing - INGRESS PROTECTION, IP 66, IMPACT RESISTANCE- IK 10 Similar to make sony, axis, honeywell Three Year Warranty (non csr)
Supply installation commisioning of 3 MP full HD IP Dome Camera VIDEO COMPRESSION H.265+/H.265+/H.264+/H.264 VIDEO Resolution 2688 x 1520 resolution, Frame Rate - upto 25-30fps, Image Sensor - 1/3"4 MP progressive scan imager, Lens type - Fixed local , Zoom lens - 2.8 mm, F2.0, Minium illumination - 0.08 lux color @ F2.0(Color 1/3s , 30 IRE) 0 lux B/W with IR LEDs on @ F2.0, Image Setting - Compression , color, Brightnrdd, sharpness, contrast, white balance, exposure control,blacklight, compensation protocol - IPv4/v6, TCP/IP, UDP, RTP, RTSP, RTCP, HTTP, HTTPS, SSL, FTP, SMTP, DHCP,PPPoE, UPnP, SNMP v2/v3, Bonjour, DNS, DDNS, IEEE 802 1X , Qos, NTP Security - User account and password protection, HTTPS, IP Filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES-256, SSH/Telnet closed FTP Disable Operation Conditions - 30 ºC to 60 ºC Casing/ Housing - INGRESS PROTECTION, IP 66, IMPACT RESISTANCE- IK 10 Similar to make sony, axis, honeywell Three Year Warranty (non csr)
Supply installation commisioning of 4K Embedded Network Video Recorder 8 Channels - MAIN PROCESSOR - Quad -core embedded processor, OPERATION SYSTEM - Embedded LINUX, AUDIO INPUT -1 Channel, OUTPUT -1 Channel output RCA, INTERFACE - 2 HDMI , 1 VGA, RESOLUTION -3840 X 2160, OSD - Camera title , Time:Video Loss; Camera lock ; Motion detection Recording, COMPRESSION- H.265/ H.264/MJPEG/MPEG4, RECORD BIT RATE- 320 Mbps RECORDING MODE Schedule Regular/ Continous, Motion detection, Alarm , Manual , Stop, TRIGGER EVENTS - Recording PTZ Tour alarm; Video Push: Email FTP Snapshot; Buzzer, VIDEO DETECTION - Motion Detection ALARM INPUT, ETHERNET - 1 RJ -45 PORT (10/100/1000Mbps), MAXIMUM NUMBER OF USERS -128 users NETWORK THROUGHOUT- Input 320 Mbps; Output 320 Mbps , SMART PHONE COMPATIBILITY - iPhone ;iPad; Android, INTERNAL HDD 4 SATA Ports, EXTERNAL HDD -1 eSATA Port , USB PORTS - 3, EMISSIONS - FCC, SAFETY EU EN 60950-1, UL Listed to UL/CSA 60950-1, ROHS Compliant ( Three Year Warranty) (non csr)
Supply installation commisioning of 4K Embedded Network Video Recorder 16 Channels - MAIN PROCESSOR - Quad -core embedded processor, OPERATION SYSTEM - Embedded LINUX, AUDIO INPUT -1 Channel, OUTPUT -1 Channel output RCA, INTERFACE - 2 HDMI , 1 VGA, RESOLUTION -3840 X 2160, OSD - Camera title , Time:Video Loss; Camera lock ; Motion detection Recording, COMPRESSION- H.265/ H.264/MJPEG/MPEG4, RECORD BIT RATE- 320 Mbps RECORDING MODE Schedule Regular/ Continous, Motion detection, Alarm , Manual , Stop, TRIGGER EVENTS - Recording PTZ Tour alarm; Video Push: Email FTP Snapshot; Buzzer, VIDEO DETECTION - Motion Detection ALARM INPUT, ETHERNET - 1 RJ -45 PORT (10/100/1000Mbps), MAXIMUM NUMBER OF USERS -128 users NETWORK THROUGHOUT- Input 320 Mbps; Output 320 Mbps , SMART PHONE COMPATIBILITY - iPhone ;iPad; Android, INTERNAL HDD 4 SATA Ports, EXTERNAL HDD -1 eSATA Port , USB PORTS - 3, EMISSIONS - FCC, SAFETY EU EN 60950-1, UL Listed to UL/CSA 60950-1, ROHS Compliant ( Three Year Warranty) (non csr)
Supply installation commisioning of 4K Embedded Network Video Recorder 32 Channels - MAIN PROCESSOR - Quad -core embedded processor, OPERATION SYSTEM - Embedded LINUX, AUDIO INPUT -1 Channel, OUTPUT -1 Channel output RCA, INTERFACE - 2 HDMI , 1 VGA, RESOLUTION -3840 X 2160, OSD - Camera title , Time:Video Loss; Camera lock ; Motion detection Recording, COMPRESSION- H.265/ H.264/MJPEG/MPEG4, RECORD BIT RATE- 320 Mbps RECORDING MODE Schedule Regular/ Continous, Motion detection, Alarm , Manual , Stop, TRIGGER EVENTS - Recording PTZ Tour alarm; Video Push: Email FTP Snapshot; Buzzer, VIDEO DETECTION - Motion Detection ALARM INPUT, ETHERNET - 1 RJ -45 PORT (10/100/1000Mbps), MAXIMUM NUMBER OF USERS -128 users NETWORK THROUGHOUT- Input 320 Mbps; Output 320 Mbps , SMART PHONE COMPATIBILITY - iPhone ;iPad; Android, INTERNAL HDD 4 SATA Ports, EXTERNAL HDD -1 eSATA Port , USB PORTS - 3, EMISSIONS - FCC, SAFETY EU EN 60950-1, UL Listed to UL/CSA 60950-1, ROHS Compliant ( Three Year Warranty) (non csr)
Supply installation commisioning of 42 "Full HD Commercial LED Display / Monitor 4.2 inches or higher Full HD VGA DVI HDMI LAN USB RGB RS 232 C IN/OUT AV IN COMPONENT IN AUDIO IN/OUT WIFI READY SPEAKERS (Sony/Samsung / Panasonic) (Three Year Warranty) (non csr)
Supply Erecting testing and commisioning of 4TB HDD Survillance ciard disk oduct Dimensions 10.2 x 2.5 x 15.2cm item mode numbers ST4000VX007 Memory Storage Capacity 4TB Flash memory installed size 4 TB Digital Storage Capacity 4TB Hard Drive Rotation Speed 5900RPM Survillance, DVRs, Hardware Interface SATA 6.0 gB/S, Graphics Card Interface PCI-E, Compatible Devies Desktop Buffer size 64 MB (non csr)
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV (92 Pole x 9 mtr =828) (1-3-27)
Supplying LED concealed type foot / step light with aluminium body for indoor/outdoor application suitable for upto 4W-6W LED including driver and erecting by making necessary arrangement/ recess in wall to make it flush with surface.(2-1-16) (For Elavation of admin building, cyber police station, VIP guest House, SP, DYSP Bungloaw)
Supplying and erecting LED street light fitting suitable for 60W lamp, including lamp, with PF > 0.95 class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete as per specification No FG-ODF/FLS-2. (2-5-5)
Supplying and erecting LED Flood light fitting of 150W, including lamp, with PF > 0.95,class IP 65 and above Housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification No FG-ODF/FLS-2 (2-5-17)
Supplying and erecting LED flood light fitting of 70- 80W, including lamp, with PF > 0.95,class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete as per specification No FG-ODF/FLS-2(2-5-14) (Facade lighting of multipurpose hall)
Supplying and erecting LED flood light fitting of 200W, including lamp, with PF > 0.95,class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete as per specification No FG-ODF/FLS-2(2-5-18) (Facade Lighting of traing center, Admin building & cyber police station)
Supplying and erecting recess mounted 20W LED wall washers, tilted 70° outwards and swivels 360° to offer best illumination on the wall with any colour with driver complete. ( Including Compatible Driver)(2-5-19) (For elevation light of Admin Building & Cyber police station)
Supplying and erecting gate/garden light fitting with 200mm dia.glass bowl suitable for upto 12W LED Lamp on provided pipe as perspecification No. FG-ODF/GLT(2-6-1) (For entrance gate)
Supplying & erecting integral post top lantern fixtures (mushroom type) suitable for LED lamp upto 12 W consisting of clear acrylic top cover, cast aluminium pole cap complete with accessories on provided pole /bracket as per specification no. FG?ODF/PTL (2-6-3) (For Garden Light of Admin building & cyber police station)
Supplying & erecting aviation obstruction light consisting of yellow painted die-cast aluminium alloy housing with integral LED aviation light comprising of aluminium housing with polycarbonate enclosure complete. (2-11-1) (For High Mast)
Supplying and erecting LED Up-Down light fitting of 2x6 or 2x8W, including lamp, with PF > 0.95,class IP 65 and above complete as per specification No k-lite 7898 or equipvalent (NON-CSR) (For elevation of training center)
Supplying and erecting LED tree up light fitting of 12W, including lamp, with PF > 0.95,class IP 65 and above complete as per specification No K- lite Nebula Midi -4267 or equipvalent (NON-CSR) (For Landscape light along the road tree)
Supplying and erecting LED flat series pole light fitting of 12W, including lamp, with PF > 0.95,class IP 65 and above complete as per specification No KP -4792 or equipvalent (NON-CSR) (For Laandscape light)
Supplying and erecting ON LOAD four pole automatic transfer switch suitable for 415V, 100A, 50 Hz, capacity with enclosure, automatic/manual inbuilt time delay, high transfer speed, excellent breaking capacity, superior making capacity, compact & light weight, erected on provided angle iron /GI frame and connected with provided leads complete.(5-1-32)
Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification No. SW-SWR/MCB.(5-3-3)
Supplying, erecting & terminating XLPE armoured cable 4 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (7-1-28)
Supplying, erecting & terminating XLPE armoured cable 4 core 16 sq. mm. copper conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU(7-2-34)
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. (7-6-10)
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.(7-6-11)
Supplying and erecting 12.5 m (clear height) High Mast (Top- 150mm, Bottom- 360mm) with lowering and raising motorized unit, lantern carriage assembly suitable for max. 6 nos. luminaries and its control gear box, lightning finial arrangement for fixing aviation light and foundation bolts on provided foundation as per specification no. OH-PL/HM (excluding luminaries ).(8-3-1)
Providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 155 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH?PL/OPL(8-3-16)
Providingt and erecting Galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification No. OH-PL/PBKT (8-3-30)
Providing and erecting Galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification No. OH-PL/PBKT (8-3-31)
Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as per specification No. EA-EP (9-1-4 )
Supplying, erecting and commissioning of diesel generating set with alternator of 62.5 kVA output continuous rating, 3 phase, 415 V, 50c/s 0.8 p. f. A.C a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters,switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level upto 75 dB at 1.0 m, provided with first filling of oil, diesel etc. as per specification no. GEN-DG (11-1-10)
Supplying, erecting and commissioning of diesel generating set with alternator of 125 kVA output continuous rating, 3 phase, 415 V, 50c/s 0.8 p. f. A.C a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters,switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level upto 75 dB at 1.0 m, provided with first filling of oil, diesel etc. as per specification no. GEN-DG (11-1-13)
Supplying, erecting, testing and commissioning of Microprocessor based AMF panel suitable for diesel generating set of above 50 kVA upto 62.5 kVA capacity Single/Three phase, 230/415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. (11-2-8) -with note 1
Supplying, erecting, testing and commissioning of Microprocessor based AMF panel suitable for diesel generating set of above 100 kVA upto 125 kVA capacity Single/Three phase, 230/415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. (11-2-11) -with note 1
Providing Cement concrete foundation in 1:2:4 with required size and length of foundation bolts and nuts (cost with wooden box is included).(16-3-5) (125kVA - 4.6x1.7x0.3) & (62.5kVA - 3.7x1.7x0.3)
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 9m & 10m high octagonal /conical GI pole). (16-3-10)
Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 12.5 m raising lowering high mast).(16-3-12)
Supplying, erecting & marking SPMCB 40A to 63A C- series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB ( 5-3-2)
Supplying and erecting marine plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete. (6-1-14)
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. (7-6-9)
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP (9-1-1)
Supplying and erecting 1 phase, 230 V, 50 Hz, submersible pump set of 0.75 KW/1HP for erection on open well, pump having discharge 35 / 270L.P.M., head 30 / 15 m & pipe of Suction 32 mm/Delivery 25 mm diameter erected with with necessary H type clamps as per specification no. WP-OSP(12-3-5)
Supplying and erecting D. O. L. Starter suitable for 250V. single phase, 50 cycles with overload element with necessary materials and connected to supply upto 3 H.P.(12-4-1)
Supplying and erecting flat flexible 3 core 4 sq mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. (12-4-9)
Supplying & erecting Water lavel controller 230/ 415V AC., Four way for under ground & Over head tank operation .(12-4-15)
Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. (1-8-1)
Supplying and erecting ISI mark modular type 3 pin 6A multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete. (1-8-10)
Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 modules duly erected. (1-8-29)
Supplying & erecting LED 20W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete.(2-1-23)
Supplying and erecting bulkhead fitting suitable for upto LED upto 12W fixed on wall. As per specification no. FG-IDF/BHF.(2-2-5)
Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B-22/E-27 base. (2-10-11)
Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification No. SW-SWR/MCB.(5-3-3)
Supplying, erecting & marking DPMCB 6 A to 32 A B- series (for lighting) in provided distribution board as per specification no. SW-SWR/MCB (5-3-7)
Supplying, erecting & marking TPMCB 6 A to 32A in provided distribution board as per specification no. SW-SWR/MCB (5-3-14)
Providing & erecting 3 Pole MCCB upto 100A, 415V, with short circuit rating 25 kA (Ics=100% of Icu ),adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB (5-5-1)
Supplying and erecting single pole and neutral distribution board (SPNDB) surface/flush mounted with 2 ways for incoming and 6 ways for outgoing SP MCB’s on iron/ GI frame as per specification no. SW-SWR/MCBDB (5-4-15)
Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted suitable for 3 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles) on iron/ GI frame. (vertical busbar type) as per specification no. SW-SWR/MCBDB1 (5-4-25)
Supplying, fixing and commissioning 2 pole,RCBO (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 6/10/16/20/25A, as per specification no SW-RCCB/RCBO. (5-6-11)
Supplying, fixing and commissioning 4 pole RCBO ( (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 6A/10A/16A/20A/25/A as per specification no SW-RCCB/RCBO. (5-6-14)
Supplying & fixing CRCA sheet Box with earthing terminals for housing 2 Pole RCCB on iron frame/laminated board complete.(5-6-9)
Supplying & fixing CRCA sheet Box with earthing terminals for housing 4 Pole RCCB on iron frame/laminated board complete. (5-6-10)
Supplying, erecting & terminating XLPE armoured cable 2 core 4 sq mm copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU (7-2-9)
Supplying, erecting & terminating XLPE armoured cable 4 core 6 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU (7-2-32)
SITC of Electric Traction Passenger Lift with Rated capacity :- 10 Passenger/680Kg Floors :- G+2 floor (3Stops/3 Landings) Travel :- 11.70 mtrs Location of Lift Machine:- MRL Rated speed :- 1.0mps VS Doors type :- COPO/TOPO Doors with frame having clear opening of 800 mm wide x 2000 mm high made from SS 304 grade sheet of 1.5mm, thick in hairline finish for car and all landing doors with SS door architraves/frames Lift car enclosure made from SS 304 grade sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. COP with SS face plate having metallic push buttons with Braille Code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with/without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor Clear Car size of 1600mm wide x 1500mm deep x 2400mm high LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille Code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port, control panel duly wired with proper size & strength copper wire for power & control circuit, with provision for addition of floor/ control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class ARD complete with necessary SMF VRLA batteries Fireman controller having fireman switch at fire Landing, CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for 60 days with 18" FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. Lift Machine of Gearless PMSM of suitable kW with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary Steel work Minor civil work for alteration if any and erection of door frames and accessories, erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails fixing of girders for mounting lift machine etc. complete as per specification no. LFT. Lift shaft available having clear size of 2100mm wide x 1900mm deep , 1500mm Pit depth, , 4250mm Overhead. (17-1-4) 1) General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. 2) Warrantee: - Job covers three years onsite warrantee for all the Lift parts with FCAMC as per the maintenance schedule. For Lift travelling up to six floors or at a speed of 1.0 mps, add as below, (A)
For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows?indicators, extension of guide rails, shaft wiring with trunking, traveling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete (A-2)
For vision panel having Size 100mm wide x 200mm high covered with fire rated laminated glass, having punched Jali as a part of the door panel SS sheet itself. (F)
SITC of Electric Traction Passenger Lift with Rated capacity :- 8 Passenger/544Kg Floors :- G+1 floor (2Stops/2 Landings) Travel :- 7.8 mtrs Location of Lift Machine:- MRL Rated speed :- 1.0mps VS Doors type :- COPO/TOPO Doors with frame having clearopening of 800 mm wide x 2000 mm high made from SS 304 grade sheet of 1.5mm, thick in hairline finish for car and all landing doors with SS door architraves/frames Lift car enclosure made from SS 304 grade sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. COP with SS face plate having metallic push buttons with Braille Code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with/without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor Clear Car size of 1300mm wide x 1400mm deep x 2400mm high LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille Code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port, control panel duly wired with proper size & strength copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class ARD complete with necessary SMF VRLA batteries Fireman controller having fireman switch at fire Landing, CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for 60 days with 18" FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. Lift Machine of Gearless PMSM of suitable kW with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work Minor civil work for alteration if any and erection of door frames and accessories, erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails fixing of girders for mounting lift machine etc. complete as per specification no. LFT. Lift shaft available having clear size of 1900mm wide x 1900mm deep. 1500mm Pit depth, 4250mm Overhead. (17-1-3) 1) General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. 2) Warrantee: - Job covers three years onsite warrantee for all the Lift parts with FCAMC as per the maintenance schedule.
For vision panel having Size 100mm wide x 200mm high covered with fire rated laminated glass, having punched Jali as a part of the door panel SS sheet itself. (F)
Harsh Constructions Pvt Ltd
M/s Super Construction Co Nagpur
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid