Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC | L1 | Accepted-AOC Lowest quoted tenderer | |
| 2 | L2₹22.3 L+₹1.8 L (8.62%)Rejected-Finance HN 2 PREETI NAGAR PHASE II FAIZULLAGANJ LUCKNOW UTTAR PRADESH 226020 | LUCKNOW | UTTAR PRADESH | 226020 | L2 | Rejected-Finance Other than lowest quoted tenderer | |
| 3 | L3₹22.4 L+₹1.8 L (8.83%)Rejected-Finance | L3 | Rejected-Finance Other than lowest quoted tenderer | |
| 4 | L4₹25.0 L+₹4.5 L (21.7%)Rejected-Finance FLAT NO 402 4TH FLOOR BLDG NO 31 HANSGEET CO OP HSG SOCIETY PANT NAGAR GHATKOPAR E MUMBAI 400 075 | MUMBAI SUBURBAN | MAHARASHTRA | 400075 | L4 | Rejected-Finance Other than lowest quoted tenderer | |
| 5 | L5₹26.9 L+₹6.3 L (30.8%)Rejected-Finance | L5 | Rejected-Finance Other than lowest quoted tenderer |
Tender Value
Refer Docs
EMD Value
₹53,760
Closing Date
7 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE Allahabad
HQ CWE New Cantt Allahabad
AUGMENTATION OF POWER SUPPLY FOR ACUTE MEDICAL WARD AND SUB ACUTE MEDICAL WARD AT MH ALLAHABAD UNDER GE (WEST) ALLAHABAD.
2022_MES_558008_1
81704/W/E8
Open Tender
Civil Works
Item Rate
180 days
Allahabad
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (West) Allahabad
₹53,760
Yes
12 Nov 2022
15 Oct 2022
9 Nov 2022
16 Oct 2022
7 Nov 2022
24 Oct 2022
Amount
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 Sqmm complete all as specified and directed.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil including bottom surface to required level or slope for laying of cable etc. complete all as specified and directed.
Returning filling in excavated soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each in soft/loose soil complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L sand cushioning with dry local sand for cable protecting under ground cable (8 cm before laying the cable and 15 cm after laying the cable) in trenches and consolidated complete all as specified and directed. Note : Punned thickness 18 cm only shall be considered for payment.
Supplying and laying reinforced precast concrete cable cover, class EHV, type 1 with peak, size 450mm x 230mm x 50mm to cover/laid over the cable in cross direction to give mechanical protection to under ground cable complete all as specified and directed.
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
S&F steel tubular electric pole, for HT line, welded (11 metre long) complete with CI base plate, bolts, nuts & screws all as specified including the following:- (a) Excavation in post hole not exceeding 1.5 Mtr wide & 2 Mtr deep for pole foundation & getting out in soft loose soil, returning, filling in the excavated soil after fixing the pole in foundation, ramming earth around in layers n.exc 25 cm thick and disposal of surplus soil to a distance n.exc 50 metres. (b) M&L for Providing PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) in foundation 600mm x 600mm x 1500 mm (planting depth) for concrete encasing the pole upto GL (c) M&L for Providing PCC 1:3:6, type C2 (using 20 mm graded stone aggregate) for plinth block /Collar above GL, 300 mm high and 450 mm dia (d) M&L for painting of pole externally with one coats of black bituminous paint (upto planting depth) and above plinth block/ concrete collar with two coats of aluminium paint over a coat of red oxide primer including preparation of surfaces including painting of 30 cm wide black bands 3 Nos with synthetic enamel paint in alternate layers upto the height of 1.5 Mtr above plinth block.
S&F cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
Supply and fix lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp for 11 KV complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected using galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
Earthing complete with galvanised copper earth plate electrode 60×60cm.×3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to20×3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
Supply and fix HT 11 KV, out door type gang operated air-break switch suitable for horizontal or vertical mounting fixed type, Triple pole (9 insulator), mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 Amps complete all as specified and directed
Supply, fixing, connecting to electrical system & testing of LT panel board ,cubical type for out door use, made out of 3.15 mm thick CRCA sheet factory made, totally enclosed of size not less that 900x600x500mm and supported with 4 Nos MS Angle legs , duly painted with two coats of powder coated paint over one coat of red oxide primer effectively PVC gaket and sealed mounted on PCC blocks double door type with locking arragnedment with handle at front and openable at front &back bothe side with required hinges heavy duty, compartemtalised suitably including provision for tapping incoming & outgoing electric connections with suitable size of aluminium lugs glands and comprising of the following accessories :- (a) High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of 400 amps rating (RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve-1 Set. , (b) Phase indication lamp, LED type(set of 3) -1 Set (c) Ammeter anolog type having measuring range (0-300) Amps with CTs etc including rotary switch to measure load of each phase : L&T/Seimens (d) Replacement of volt meter having measuring range (0-500) volt with rotary switch to measure voltage of phase R.Y.B make : L&T/AE (e) Grouting of panel including earth work as required PCC (1:3:6) type D-2 using 20 mm gradeded stone & plastering with (1:4 )cement sand etc complete. (f) MCCB 4 Pole 160 Amp 415 volt thermal adjustable ,type with 25 KA breaking capacity & spreader both side as Incomming cotrol device : 01 Nos. (g) MCCB 4 Pole 100 Amp 415 volt thermal adjustable ,type with 25 KA breaking capacity & spreader both side as Incomming cotrol device : 01 Nos. (h) MCCB 4 Pole 63 Amp 415 volt thermal adjustable ,type with 25 KA breaking capacity & spreader both side as Incomming cotrol device : 01 Nos.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size size 35 sq mm 3½ core complete all as specified and directed.
Supply, fixing, connecting, & testing LED streetlight fitting of 25 Watt high pressure die cast aluminium housing, with minimum 120 lumen/watt system efficacy, covered potted designed driver of same make as fitting, heat resistant toughened glass with silicon gasket for IP-66 protection, better optics for uniform distribution roadway luminaires complete and fixing on GI bracket 1.2 mtr length on steel tubular pole/bldg and connecting the fitting electrically using 3 way 10 amp connector and s&f PVC conduit 20 mm & pvc copper cable 2.5 sqmm 3core from junction pole box/ceiling rose to fitting complete all as specified and directed.
Supply & fixing MCCB 4 pole, 100 Amps 415 Volt,16 KA with Sheet metal enclouser of suitable size as per site requirement & making connections with aluminium lugs, testing as required complete all as specified and directed.
Lightening Conductor Supply of 8mm Alluminum Round Conductor complete as specified in drawing & Meets the requirements of DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305) , OBO Type No. RD 8/ALU complete all as specified and directed.
Supply of roof conductor holder for sheet as specified in drawing , Bottom section & Conductor holder made of stainless steel (V2A) with Ø 8.5 mm slot at bottom @ every 1 mtr distance. OBO Type No. 159 V-AV (5217 07 5) complete all as specified and directed.
Providing of cross universal connector: For T and cross connection, to route vertical down conductor /mesh formation made of hot dipped galvanised iron with necessary screws etc as required. Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts . OBO Type No.251 8- 10 ( 5312 03 5 ) complete all as specified and directed.
Providing of expansion piece with connector: For equalising temperature related length changes. ncessary on conductors length over 20 meters. For round conductor Rd 8/ALU. OBO Type No. 172 AR ( 5218 92 6 ) complete all as specified and directed.
Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Conforms to the requirements according to DIN VDE 0185-305 (IS-IEC 2305)(2nos/expansion piece ). OBO Type No. 249 8-10 ST ( 5311 50 0 )
Down Conductor Supply of 8 mm Aluminum Round Conductor complete as specified in drawing & Meets the requirements of DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305) , OBO Type No. RD 8/ALU complete all as specified and directed.
Supply of roof conductor holder for parapet- Polyamide Conductor holder: with M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance OBO Type No. 177 30 M8 (5207 46 0 ) complete all as specified and directed.
Supply of Test Joint (Folding Clamp) made of SS,suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer OBO Type No. 271 8-10(5317481) complete all as specified and directed.
Earthing Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor shall be of Hot Dipped & Cross sectional area of 90mm square According to DIN EN 50164-2 (VDE 0185 part 202) Meets the requirement of VDE0185/305(IS-IEC 62305) Zinc coating: 500 g/m square (Approx :70 micron coating) Should be tested and used exclusively for lightning protection earthing system and ring equipotential bonding. OBO Type No. 5052 DIN 30X3 ( 5450436) complete all as specified and directed.
Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. OBO Type No. 255 FL30 FT (5314 53 4 ) complete all as specified and directed.
Providing of flat conductor holder suitable for FL 30. Installed with 2 hexagonal bolts. OBO Type No. 166 LS 70 ( 5226 57 0 ) complete all as specified and directed.
Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. OBO Type No.356 50 ( 2360 05 5 ) complete all as specified and directed.
Supply of UL Listed & CPRI Tested maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2. OBO Type No. 17 3000 CCER (5450014) complete all as specified and directed.
Universal clamp made of SS to connect rod with flat conductor. OBO Type No. 17 25 TC (5450068) complete all as specified and directed.
Earth conductivity enhancing compound shall be of 25 kg/pit tested as per IEC 62561- TCLP tested. OBO Type No OEC 2 25 (5450058) complete all as specified and directed.
The above arrangements shall be provided with heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system. OBO Type No.UFE (5450030) complete all as specified and directed.
M&L for point wiring with FRLS PVC insulated unsheathed stranded copper conductor cable 1.5 sqmm (nominal area) 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly drawn in and including in-stove enamelled steel conduit, medium grade Surface conduit with all fixing accessories of 20mm dia, using new MS sunk terminal boxes of thickness not less 1.2mm, new 3mm thick laminated flame proof sheet cover with brass screw and cup washers with all acessories and making good to disturbed conceal surfaces complete all as specified and directed for the following :-
One light/fan point controlled by one switch
All as per item No. 37.00 here in before but point wiring using 4.0 sq mm or 36/0.30 or 80/0.20 or 50/0.25 (Nominal area) FRLS PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet, suitable for AC point “ independent board”.
S&F ceiling rose surface type bakelite 65x50mm three terminal complete all as specified and directed.
S&F Switch flame proof rotary type with termination box in LM6, 16A, Double pole 250V complete all as specified & directed.
S&F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 25A, 250V, 2P+earth complete all as specified & directed.
S&F sheet metal enclosure for MCB's 240 volt 8 way single pole and neutral with 200 amps rated busbar double door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wall complete all as specified and directed.
S&F MCB single pole, 6 to 32 amps rating, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
S&F MCB single pole & neutral 40/63 amp, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
M&L for two single core (submain) FRLS PVC insulated cable and one single core green PVC insulated copper conductor earth continuity cable as mentioned below is drawn in and including in stove enamelled steel conduit not less than 20 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making good to disturbed surfaces with cement mortar ratio of 1:4 and colour wash complete all as directed. Note :- (I) The cost for cutting, chases required shall deemed to be included in the quoted unit rate. (II) Two run of submain wire, one run of earth wire and one run of PVC conduit shall be measured one RM
2x6.0 sq. mm + 1x4.0 sq. mm earth wire
Supply & fixing surface /wall mounted light fitting in CRCA powder coated white housing with pre wired suitable for single T8 LED tube along with supply and fixing one number LED tube in polycarbonate housing of nominal wattage - 18 Watt, Lumen out put - 2100 Lm, Colour Temp - 6500 Kelvin, Size & Length - G13/ T8/ 4 Feet with integral/in built driver, having short circuit and surge protection including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Cat Part No for batten:- REGALBATTENT8UPTO1X18WDSBSWH of make Havells 'or' IGP161LT8-16 of make Crompton 'or' TMC501 P 1xT-LED 22W P3241 of make Philips or its equivalent as approved Cat Part No for Tubelight:- PHOTANULTRA2.01213T8SSTL18WLED865SPC of make Havells 'or' LTT8-20 of make Crompton 'or' MAS LEDtube 1200MM 18W865 T8 I-2100 lm of make Philips or its equivalent as approved
M &L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and salt PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type BO using 20mm graded stone aggregate cover re-inforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete all as specified and directed.
Ajanta Associates
Titco Electricals
RAMESH ENTERPRISES
Super Automobiles
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .