Installation of Automatic Fire Detection System
2022_DRDO_517322_1
ITR/23ATT001/FFG/CMS-II
Open Tender
Miscellaneous Goods
Supply
120 days
ITR CHANDIPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
ITR Chandipur
17 Aug 2022
8 Apr 2022
26 Apr 2022
9 Apr 2022
25 Apr 2022
20 Apr 2022
10 Apr 2022 - 13 Apr 2022
19 Apr 2022
Installation of Automatic Fire Detection System
Power Series NEO Panel, 8 on-board zones, expandable to128 wireless and hardwired zones, 4 PGSM output: expandable to 144, 8 partitions, 1000 event buffer and 94+ user codes
220V CE Transformer
Batteries 12V -7AH
Wireless Full Message LCD Keypad
Power G Host Transceiver Module to support up to 128 wireless Zones, all wireless detectors are fully supervised for communication integrity
Wireless Power G Smoke and Head Detector, provides alert for smoke, tamper and device low battery, fully supervised, maintenance and battery condition Indication, built in 85db alarm Buzzer
Wireless Power G Repeater, extend the overall range, LED indication for power failure, activity and installation performance diagnostics
Wireless Manual Call Point
Wireless PowerG Indoor Siren, 110db siren, different audible alerts for Intrusion and Fire
Wireless PowerG Outdoor Siren, fully Supervised, 110db Siren Output, Strobe Light functionality for visual indication
Power series NEO Internet Comm
Supply and installation of UL, FM, VDS approved ASD 532 single channel aspiration smoke detection system, can connect 120 mtr pipe. The aspiration system smoke chambers shall be replaceable. The system design based on VDS-tested calculation software ASD pipe Flow. The system shall have a high power DUAL LED combined with sensitivity with low aerodynamic resistance and the utmost resistance to soiling. The alarm sensitivity shall be 0.02 – 10% /m. The system housing shall have IP 54 rating. Suction pressure > 400 Pa.
Supply and installation of Filter box small including filter mat. It shall be connected to the sampling pipe before ASD, the panel should have inbuilt relay odule with 3 nos alarm signal and 2 nos alarm signals. The PCB should be of hot redundancy type with swappable.
Supply and installation of Filter box small including filter mat. It shall be connected to the sampling pipe before ASD
Supply and installation of Fire alarm hooter
Supply and installation of power supply and Battery backup for 30 minutes.
Supply and installation of UPVC pipes 25 mm necessary accessories for the sampling pipes.
Supply of 80 Litres Capacity Seamless Cylinder CODE approved.
Supply of UL listed Brass Electric Control Head operated electrically from the Detection & Control system or locally with a manual lever on the control Unit
Supply of UL listed Pressure Operated Control Head which allows fore pressure actuation slave cylinders an is mounted directly on top of the slave cylinders valve
Supply of UL listed Master Cylinder Adapter Kit used to actuate the Slave Cylinder
Supply of UL listed flexible Action Hose (Plot pressure is directed to a pressure operated control head on each cylinder valve using 1/ 4 inch actuation house)
Supply of UL listed Brass Male Elbow for the connection flexible house
Supply of UL listed 2nd manifold Check Valve installed at discharge manifold to allow removal FK-5-1-12 Cylinder form the manifoCF3Id while still retaining a closed system.
Supply and fitting of UL listed FK-5-1-12(FK 1230) Fire Protection fluid compound or carbon, fluorine and oxygen (8CF2C (O) CF )CF3)2)
Supply of UL listed discharge Nozzles are designed to provide the proper flow rate and distribution of FK 1230 to total flood a hazard area : 360/180 deg.
supply of UL listed flexible reinforce rubber Discharge Hose carbon steel fitting MOC (120 Ltr Cylinder)
Supply of Cylinder strap for 80 Ltr. Cylinder
Supply of UL listed piping agent discharge pressure switch
Supply of Manual gas release Unit
Supply of Manual gas abort Unit
Supply of Sounder with strobe
Supply of smoke detector with base
Supply of Heat detector with base
Supply of gas discharge indicator housed MS/ABS housing
Supply of discharge pipe with support and Fitting, CS Seamless to ASTM A-106 Schedule 40
Supply of 2C 1.5 SQM armoured copper core cable with all necessary accessories for the installation
Td200ea (200 cm) (contain 5010 gms + 5 ‘Clean gas agent HFC-227ea)
Accessories for installation
Installation testing and commissioning of the system
KRIAZ SAFE SOLUTIONS LLP
NITIN FIRE PROTECTION INDUSTRIES LIMITED
Systematic Communication Pvt. Ltd.
TAURUS AUTOMATION AND SERVICES
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .