Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.8 LAccepted-AOC H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹19.6 L+₹84,969.25 (4.54%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹21.5 L+₹2.7 L (14.6%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹21.7 L+₹3.0 L (15.8%)Rejected-Finance S 17 77 1 CHARAN NAGAR COLONY NADESAR VARANASI UTTAR PRADESH PIN 221002 | VARANASI | UTTAR PRADESH | 221002 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹21.9 L+₹3.1 L (16.7%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
6 Apr 2023, 6:00 pmClosed
GE 865 EWS
GE 865 EWS, PIN-913 865 C/o 56 APO
REPAIR REPLACEMENT AND MAINT OF STREET LIGHT FITTINGS AND OUTDOOR ILLUMINARIES AND HIGH MAST LIGHTS AT SECTOR A AND B UNDER AGE EM II OF GE 865 EWS
2023_MES_585985_1
865/EWS(NIT-30)/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE 865 EWS
As per tender documents and as per policy in vogue
9 documents required · 9 mandatory
₹500
GE 865 EWS
₹88,000
Yes
16 May 2023
16 Mar 2023
13 Apr 2023
16 Mar 2023
6 Apr 2023
29 Mar 2023
Amount
Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 mtr in depth for foundation etc or for electric poles stay foundation and under ground electric power cables etc n.exc 10Sqm on plan and n.exc 1.5m in depth and getting out in hard/dense soil complete all as specified and directed.
Returning filling, including spreading, levelling , watering and well ramming in layers not exc 25 cm thick in hard/dense soil complete all as specified.
Removing excavated material (soil) not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Supply and spreading sand for cusioning to protection of underground cables, laid 8 cm before laying and 15 Cm after laying of cable and punned to form an over all layer of 18 cm thick, completeall as specified and directed by Engr-inCharge. Note: Punned thickness shall be measured and paid.
Supply and laid Un-reinforced precast concrete cable cover, class LV, Type- 1 flat, size 250 mm x 150 mm x 40 mm complete all as specified and directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including making connection with street light box or OH line using PVC insulated and sheathed single core multi stranded aluminium conductor cable of size 1.5 Sqmm including taking down old existing street light complete all as specified and directed by Engr-in-Charge. Make : As per PS
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including making connection with street light box or OH line using PVC insulated and sheathed single core multi stranded aluminium conductor cable of size 1.5 Sqmm including taking down old existing street light complete all as specified and directed by Engr-in-Charge. Make : As per PS
Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including making connection with street light box or OH line using PVC insulated and sheathed single core multi stranded aluminium conductor cable of size 1.5 Sqmm including taking down old existing street light complete all as specified and directed by Engr-in-Charge. Make : As per PS
Supply and fixing LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including making connection with street light box or OH line using PVC insulated and sheathed single core multi stranded aluminium conductor cable of size 1.5 Sqmm including taking down old unserviceable street light complete all as specified and directed by Engr-in-Charge. Make : As per PS
Supply and fixing LED flood light 70 watt , 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including connection of copper wire including taking down old unserviceable light fittings complete all as specified and directed by Engr-in-Charge. Make :As per PS
Supply and fixing LED flood light 100 watt , 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including connection of copper wire including taking down old unserviceable light fittings complete all as specified and directed by Engr-in-Charge. Make :As per PS
Supply and fixing LED flood light 120 watt , 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including connection of copper wire including taking down old unserviceable light fittings complete all as specified and directed by Engr-in-Charge. Make :As per PS
Supply and fixing LED flood light 150 /170 watt , 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including connection of copper wire including taking down old unserviceable light fittings complete all as specified and directed by Engr-in-Charge. Make :As per PS
Supply and fixing LED flood light 200 /210 watt, 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including connection of copper wire including taking down old unserviceable light fittings complete all as specified and directed by Engr-in-Charge. Make :As per PS
Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete connection of copper wire including taking down of old unserviceable light fittings complete all as specified and directed by Engr-in-Charge. Make Havells Cat part No LHEVBGP7UN6K025 or Crompton Cat part No LPTO-40-CDL or equivalent make in Bajaj/Wipro.
Repairs of existing light fitting fixed on High Mast of any type and height by lowering down the fitting with wrench machine, replacing the unserviceable/defective parts/lights from fitting and raising the fitting on high mast complete all as specified and directed by Engr-in Charge. Note: Spares as required will be measured and paid for separately under respective items.
Supply and fixing in replacement driver for LED street light 20 Watt to 50 watt complete all as specified and directed by Engr-in-Charge. Make : As per PS
Supply and fixing in replacement driver for LED street light 50 Watt to 160 watt complete all as specified and directed by Engr-in-Charge. Make : As per PS
Supply and fixing in replacement Street light panel with astronomical timer switch assembly-01 Nos with Contractor rating 65 TP, MCB TPN 63 Amps, 240 volts and all accessories to accommodate on sheet metal enclosures box with protection to each outgoing phase having single pole MCB SP 32 Amps-4 Nos and having auto/manual switch operation including connection with copper cable including proper angle iron with proper load size for holding the timer box and PCC foundation complete all as specified and directed by Engr-in-Charge. Make : As per PS
Sub main wiring with earth wire with the size (2x1.5 Sqmm) 240 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC casing caping ISI marked with all accessories etc with one run of 1.5 Sqmm (1x1.5 Sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, sinking of MS boxes and making good to match with existing surfaces including taking down of existing submain wiring complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 1.5 Sqmm (2x 1.5sqmm), 1 run of 1.5 Sqmm (1x1.5 sqmm) cable and one metre of casing caping will be measured as one unit.
Sub main wiring with earth wire with the size (2x2.5 Sqmm) 240 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC casing caping ISI marked with all accessories etc with one run of 2.5 Sqmm (1x2.5 Sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, sinking of MS boxes and making good to match with existing surfaces including taking down of existing submain wiring complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 2.5Sqmm (2x 2.5sqmm), 1 run of 2.5Sqmm (1x2.5 sqmm) cable and one metre of casing caping will be measured as one unit.
S&F in replacement of GI Bracket made out of 40mm dia medium grade pipe 1.5m length to bend to shape for fixing on pole and suitable for all type of street light with 02 Nos clamps of flat iron (40 x4mm) nuts, bolts and washers including painting with two coats of aluminium paint over a coat of primer complete all as specified and directed.
S&F in replacement of GI Bracket made out of 50mm dia medium grade pipe 1.5m length to bend to shape for fixing on pole and suitable for all type of street light with 02 Nos clamps of flat iron (40 x4mm) nuts, bolts and washers including painting with two coats of aluminium paint over a coat of primer complete all as specified and directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one 4 Sqmm twin core cable flat or circular including taking down old existing unserviceable cable complete all as specified and directed by Engr-in-Charge. Make: As per PS
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one 6 Sqmm twin core cable flat or circular including taking down old existing unserviceable cable complete all as specified and directed by Engr-in-Charge. Make: As per PS
Supply and Laying, jointing and testing in replacement underground PVC XLPE insulated armoured and PVC sheathed LT 1100 volts grade (heavy duty) electric cable with aluminum conductor, cross sectional area 10 Sqmm 2 Core confirming to IS-1554 laid in ducts/through pipes in floor, on poles, in trenches including taking down existing old UG cable complete all as specified and directed by Engr-in-Charge. Make :- As per PS
Supply and Laying, jointing and testing in replacement underground PVC XLPE insulated armoured and PVC sheathed LT 1100 volts grade (heavy duty) electric cable with aluminum conductor, cross sectional area 10 Sqmm 4 Core confirming to IS-1554 laid in ducts/through pipes in floor, on poles, in trenches including taking down existing old UG cable complete all as specified and directed by Engr-in-Charge. Make :- As per PS
Supply and Laying, jointing and testing in replacement underground PVC XLPE insulated armoured and PVC sheathed LT 1100 volts grade (heavy duty) electric cable with aluminum conductor, cross sectional area 16 Sqmm 4 Core confirming to IS-1554 laid in ducts/through pipes in floor, on poles, in trenches including taking down existing old UG cable complete all as specified and directed by Engr-in-Charge. Make :- As per PS
Supply and Laying, jointing and testing in replacement underground PVC XLPE insulated armoured and PVC sheathed LT 1100 volts grade (heavy duty) electric cable with aluminum conductor, cross sectional area 25 Sqmm 4 Core confirming to IS-1554 laid in ducts/through pipes in floor, on poles, in trenches including taking down existing old UG cable complete all as specified and directed by Engr-in-Charge. Make :- As per PS
Supply and Laying, jointing and testing in replacement underground PVC XLPE insulated armoured and PVC sheathed LT 1100 volts grade (heavy duty) electric cable with aluminum conductor, cross sectional area 35 Sqmm 3.5 Core confirming to IS-1554 laid in ducts/through pipes in floor, on poles, in trenches including taking down existing old UG cable complete all as specified and directed by Engr-in-Charge. Make :- As per PS
Supply and laying of Galvanised iron tubes, 'light grade' 40 mm dia bore including all fittings laid in trenches or under road crossing as protection pipe or fixed to walls/poles with clamps including bolts, nuts and washer including taking down old steel tubing and connections complete all as specified and directed by Engr-in-Charge. Make: As per PS
Supply and laying of Galvanised iron tubes, 'light grade' 50 mm dia bore including all fittings laid in trenches or under road crossing as protection pipe or fixed to walls/poles with clamps including bolts, nuts and washer including taking down old steel tubing and connections complete all as specified and directed by Engr-in-Charge. Make: As per PS
S&F in replacement Timer switch with sensor alongwith Pre-down switching off timer (nature switch), single phase contractor, incoming MCB and Outgoing MCB rating of 20-25 Amps and main load circuit wiring (Copper) of min 10 Sqmm operating illumination level for switching ON should be less than 60 lux for 30 seconds and for switching off must be greated than 10 lux for 30 seconds, multiple option switch for automatic and manual operations, cabaple to handle lightning load upto 5KW per phase, including power contactor capacity 25 Amp conforms to IEC 60947-4-1 IS 13947-4-1 completely enclosed with plastic body panel conforming to IP 66 degree of protection complete all as specified and directed by Engr-in-Charge.
S&F in replacement Timer switch with sensor alongwith Pre-down switching off timer (nature switch), Three phase contactors, 3 Nos, incoming MCB and 3 Nos Outgoing MCB rating of 16-20 Amps each and circuit wiring (Copper) of min 10 Sqmm operating illumination level for switching ON should be less than 60 lux for 30 seconds and for switching off must be greated than 10 lux for 30 seconds, multiple option switch for automatic and manual operations, cabaple to handle lightning load upto 5KW per phase, including Power contactor capacity 16/20 Amp per phase conforms to IEC 60947-4-1 IS 13947-4-1 completely enclosed with plastic body panel conforming to IP 66 degree of protection complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of MCB TPN 63 Amps 'C' Series complete all as specified and directed by Engr-in-Charge. Make :- As per PS
Supply and fixing in replacement of MCB SPN 40-63 Amps 'C' Series complete all as specified and directed by Engr-in-Charge. Make :- As per PS
Supply and fixing in replacement of MCB SP 06-32 Amps 'C' Series complete all as specified and directed by Engr-in-Charge. Make :- As per PS
Supply and fixing in replacement FR/PVC pole box for loop in and loop out of size 210mm x 160mm x 98mm including 3 pole and Neutral bakelite connector and one SP 6 Amp MCB and necessary clamp and nut bolts for fixing arrangements complete all as specified and directed by Engr-in-Charge. Make :- As per PS
Material and labour for earthing complete with galvanised steel earth plate 600 x 600 x 6 mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level connected to and including Galvanized earth lead wire of size 4 mm dia by means of nuts, bolts, washers etc made of and connected to test point and earth dolly as all shown in electrical plate No.3 of SSR Part-I 2009 connected to earthing test point specified or indicated including testing on completion and excavation and earth work in any type of soil PCC (1:3:6) type C1 in chamber, pre cast RCC slab 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.0 kg/Sqm) with cast iron frame, funnel, with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore light grade GI protection pipe, test point etc incluidng taking down of old u/s earthing set complete all as specified and directed by Engr-in-Charge. Note: (i) Item includes the cost of 7.5 m GI pipe for protection of earth lead. Any additional length shall be adjusted through deviation order. (ii) Item includes the cost of 7.5 m GI earth lead. Any additional in length shall be adjusted through deviation order ( For Main DBs ) (iii) Item includes the cost of Charcoal and commercial salt ( For Main DBs )
Ms Salaria Builders
HEENA CONSTRUCTION CO
Charan sales and Service
Rampal Singh Contractor
Horizon Construction Company
SUMEET TRADING CORPORATION
Sona Enterprises
M/S NANCY ENTERPRISES
PADMA ENTERPRISES
M.S Sharma Enterprises
national engineering
bharat construction
gurchan singh & sons.
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .