Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.8 LAccepted-AOC NO 439 AHIV ADAN 11ND FLOOR 2RD STAGE INDIRA NAGAR BANGALORE 560 075 | BENGALURU URBAN | KARNATAKA | 560075 | L1 | Accepted-AOC LOWEST QUOTED HENCE ADMITTED | |
| 2 | L2₹32.9 L+₹1.0 L (3.28%)Rejected-AOC | L2 | Rejected-AOC NOT LOWEST QUOTED HENCE NOT ADMITTED | |
| 3 | L3₹33.7 L+₹1.9 L (5.90%)Rejected-AOC | L3 | Rejected-AOC NOT LOWEST QUOTED HENCE NOT ADMITTED | |
| 4 | L4₹35.0 L+₹3.1 L (9.85%)Rejected-AOC | L4 | Rejected-AOC NOT LOWEST QUOTED HENCE NOT ADMITTED | |
| 5 | L5₹35.3 L+₹3.5 L (10.9%)Rejected-AOC 227 2 5TH B MAIN ROAD 2ND BLOCK HRBR LAYOUT KALYAN NAGAR BANASAWADI BANGALORE 560 043 | BENGALURU URBAN | KARNATAKA | 560043 | L5 | Rejected-AOC NOT LOWEST QUOTED HENCE NOT ADMITTED |
Tender Value
Refer Docs
EMD Value
₹74,000
Closing Date
20 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COL MANOJ NEGI
CWE AF North Bangalore Bellary Road JC Nagar Post Bangalore 560006
IMPROVEMENT TO (E/M) INSTALLATION AT DCMU AT HQTC (U) UNDER GE (AF) BANGALORE
2022_MES_568676_1
87473CWEAFNBAN
Open Tender
Civil Works
Item Rate
330 days
GE (AF) BANGALORE
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (AF) BANGALORE
₹74,000
Yes
10 Apr 2023
12 Dec 2022
27 Feb 2023
13 Dec 2022
20 Feb 2023
23 Jan 2023
14 Dec 2022 - 21 Dec 2022
Amount
Surface dressig n exc 15 cm deep in soft/ loose soil on uneven surface of natural ground filled up area, removing vegetation, scrappiing high patches and filling in low patches with the scrapped soil to give and even & neat look as in road side berms.
Surface excavation in soft/ loose soil n. exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out. All as specified and directed.
Excavating in trenches, n. exc 1.5m wide and n exc 1.5m in depth, for foundation etc, or for shafts, wells cesspits, manholes, pier holes etc n exc 10 sqm on plan and n exc 1.5m in depth and getting out in soft/ loose soil.
Returning filling in including spreading, levelling, watering and well ramming in layers n. exc 25 cm thick in soft / loose soil complete all as directed.
Removing excavated materials outside MoD land exc 5Km and depositing where directed at a level not exceeding 1.5m above the starting point in soft / loose soil.
M & L for Hardcore of gauge n exc. 63mm, with broken stone and boulder, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surfaces.
M & L cement concrete type C-2,1:3:6, using 40mm graded aggregate as in foundations, filling and mass concrete.
M & L for sand filling under floors or in foundations including watering and consolidation.
M & L for Pre-cast cement concrete block type C1 1:3:6 (20mm graded stone aggregate masonry with solid blocks, exc. 10cm in width and setting in mortar 1:6 complete. All as specified and directed.
M & L for rendering 15mm thick cement plaster in cement morter 1:4 with water proofing compound, on fair faces of brick work or concrete sufaces, finished even and smooth without using extra cement.
Supply only integral water proofing compound
M & L for 2 coats of cement paint over a coat of priming plastered and other surfaced with alkali resistant priming paint including preparation of new surfaces all as specified.
M & L for 100mm thick Cement concrete type B-2, 1:2:4 (40mm graded stone aggregate) as in flooring, foot path, hard standing, plinth protection, bases of water tanks etc.
Supply,installation,testing & commissioning of 11 KV Outdoor type 630 Amps RMU one side extensible 03 way floor mounted with internal copper bus bars(3 NOs) and consisting of 02 nos One incoming and two out going) fixed motorized Load Break Switch and 1 no. fixed type motorized Vacuum Circuit Breaker(CCV+). All live parts, bus bars, LBSs connections of RMU should be enclosed in one tank to avoid multiple interconnections & sealed for life robotically welded non magnetic and non ferrite grade stainless steel tank Grade 304 of minimum 2.5 mm thick having IP67 degree of protection filled with SF6 gas insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. The unit shall have front cable entry for ease of installation and shall have site replaceable bushings for ease of troubleshooting during breakdown.Also, the outdoor enclosure door shall cover the full length of the switchgear. It is preferable to have a design of accomodating minimum five nos. modules in a single tank wherever applicable .RMU should have complete accessories such as Terminal boots, VPIS, cable supports, all front cable termination boots,battery-charger, mechanical indications for Load break switch ON/OFF, Manometer as per with IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694. Suitable for altitude of installation up to 1500m as per IEC 60120. Bushings shall be bolted type top mounted outside the tank for connection of external bus bar . The unit shall include the following with all necessary standard fitting and technical speciifcations for Load break switch , VCB etc as given in Annexture 'A' & ' B ' given in particular speciifcation for locations at CCC. Make : ABB/ Siemens / Schneider Note :i) All civil works incl foundation for RMU to be carried out as per manufacturer's speciifcation & drawings and the amount for the same are included in the rates quoted. ii) Necessary T & P , trasportation etc are included in the rates quoted.
Material & labour for Earthing complete with galvanised steel earth plate electrode 60 x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised iron strip of 32 x 6mm as earth lead by means of bolts and nuts check nuts and washers made of galvanised iron or steel earth strip protected by and including GI pipe 40mm bore (light grade) all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion including necessary earth work excavation in any type of soil and concrete pit using PCC (1:3:6) Type C1, precast RCC (1:1.5:3) Type A1 cover slab of size 40 x 40 x 5 cm reinforced with 8 mm dia TMT bars @ 150mm C/C on both ways with one handle for lifting, made out of 8mm dia MS bars embedded in pre-cast cover slab, funnel with wire mesh 20mm bore galvanised or steel pipe(Light grade) for watering, charcoal and salt in alternate layers including provision of earth wire protected by 40mm dia light grade GI pipe complete all as specified and as directed.
Supply , laying, jointing, testing & commissioning in pipes/ducts /trenches / under floor/under road cables XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured electric power calbe (Heavy duty) with aluminium conductor 11 KV 'E' grade of size 185 Sqmm 3 core, complete all as specified and directed by Engr-in-Charge Make Havells /Polycab.
Supply and fix cable jointing kit for 11 KV grade cable for out door termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 120 Sqmm to 185 Sqmm
S&F galvanised iron strip 32 x 6mm for earth continuty
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure.
Supply and Fix GI tubing 'Light' grade 100 mm dia for cable protection fixed in poles/walls/laid under roads/crossing all as specified.
S&F root indicator for HT 11 KV cable of size 185 sqmm made of GI plate with angle iron 20cmx20cm and 40cm long Including PCC work.
M&L cement concrete type B- 1, 1:2:4 using 20mm grade aggregate in mass concrete complete all as specified and directed.
Excavation in trenches not exc. 1.5m wide and not exc 1.5m in depth and getting out in hard/dense soil for laying of cable trenches all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layer not exc 25cm thick hard/ dense soil all as specified.
Removal of surplus soil (excavated soil) to distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point and all specified.
Supply and spread dry clean river sand in trenches for cable cushioning all as directed and specified.
Supply and laying un-reinforced precast concrets cable cover class HV Type 1 flat size 300x180x40 MM
M/S MECHANICAL ENGINEERING and ELECTRICAL CONTRACTORS
M/s STAR ELECTRICALS
SREE VARU ELECTRICALS
M/s BHOOMI ELECTRICALS
devan enterprises
G K CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .