Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹5,000
Closing Date
24 Sept 2020, 5:00 pmClosed
GMM
Sanat Ghar Bemina
Rate Contract for LED LIGHTS HIGH MAST FLOOD LIGHTING SYSTEM
2020_SICOP_103961_1
15aaa1 SICOP (GMM) of 2020 Dated 09-09-202
Open Tender
Miscellaneous Goods
Item Rate
30 days
Sanat Ghar Bemina
Please refer Tender documents.
2 documents required · 2 mandatory
₹25
GMM
₹5,000
29 Sept 2020
9 Sept 2020
25 Sept 2020
9 Sept 2020
24 Sept 2020
9 Sept 2020
Amount
Providing supply , installation , testing and commissioning of 50hz, outdoor type, delta star, aluminum wound, ONAN cooled, distribution transformer, confirming to is: 2026-1977 with latest amendments dully tested, painted and oil filled to is: 335 of 1983 with latest amendments the transformer shall be complete with following:- A) oil conservator with oil level indicator, minimum level marking and drain plugs, B) top mounted ht bushings with arcing horn. C) LT bush enclosure . D) lifting lugs and bi-directional roller E) rating diagram and terminal marking plate F) explosion vent and valves for filtration ,drainage and filling e. With necessary plugs , including air release plug
a). 100 KVA, 11/0 433kv
b) 200 KVA, 11/0 433kv
c).250 KVA, 11/0 433kv
a). Rating 15 KVA
b). Rating 25 KVA
c). Rating 30 KVA
d). Rating 35 KVA
e). Rating 50 KVA
f). Rating 100 KVA
g). Rating 200 KVA
h). Rating 250 KVA
Providing supply , installation , testing and commissioning of 35 mm sq 11 kv grade, 3 core aluminum conductor abc cable , XLPE insulated with aluminum alloy messenger wire for carrying the weight of the cable of maximum system voltage of 12 kv ( Havells / PolycablSkytone/ Gloster make),the cable should be anchored on the poles using suitable galvanized hooks. If substation capacity is enhanced to 250 kva 50 mm cable amount will be enhanced
Outdoor end kiits heat shrink type for above 35 mm sq 11 KV Three core abc cable type
ST poles 9_mtr Long complete with Base Piate and top cap Confirming to IS 410 SP 33 to be erected in cement concrete 1:3:6 (1 cement 1 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation , refilling , formwork etc as required at site.
11 KV GOD for tapping points and substation
11 KV Lightening Arrestor. The arrestor should be station type and of 10 KA rating including clamps of appropriate size.
11 KV Drop out fuse / Arcing horn gap
Chemical Earthing
1OOX50X5OX6 NIS channeis,8.5 feet long including cutting ,fabrication and installation on ST poles for Distribution Transformer (DTR) frame to be erected as per REC guidelines using GI clamps.
75X5OX5Ox6 MS channels 85 feet long including cutting , fabrication and installation on ST poles for DTR frame accessories like LA GOD, DO etc, to be erected as per REC guidelines for DTR frame and tapping point using GI clamps. Note: Any additional MS channels or angle iron as may be required at site shallbe paid as per weight.
45x45x5MS angle iron 8.5 feet long including cutting , fabrication and installation for belt for transformer
Fabricated clamps of 50x5mm GI strip for erection of DTR channels etc.
Supply,Testing and commissioning of HT meter
35 mm sq core XLPE armored aluminum conductor 11 KV cable of maximum system voltage of 12 kv ( Havells/Poly cab Paramount / Skytone make)
HT Cable end kit hear shrink outdoor type for 35 sq. mm XLPE 11 KV cable mentioned above at sr No. 14 ( Raychem/ Mseal/ Powertech /3M)
185 mm sq Aluminum armoured CLPE three and a half core LT cable 1.1 KV grade of Havelles , Polycabl , Paramount , Skytone make
3 inch dia 2.5 inch dia A class GI pipe for use as conduit for XLPE cable for DTR as required at site
Making of G.I pipe earthings using 2” dia 8 feet long GI pipe as per RE guidelines with 12”x12” cast iron mahhole cover fixed in requisite masonary work
Making of plate eartning ( Copper plate 2’x2’) including 25x3mm GI earth riser strips for DG and GI masts
Cement Concrete Foundation using M15 for servo 8’x6’x4’ size and for DG set 6’x5’x4’ size (or size as specified by DG manufacturer for DG only) with 3 inch slab and plastering complete including form work etc.
Supply Installation , testing and commissioning of LED Flood Light designed for outdoor Sports Lighting applications having Housing of Pressure Die Cast aluminum construction with thermal management heat sink design, Flood light Cover shall be of toughened optically clear glass construction mounted in a metal frame with silicon gasket for IP protection.500 Watts LED flood Light and driver enclosure IP protection IP 65 minimum. Flood light should be equipped = with Cradle type epoxy powder coated adjustable MS flood light bracket suitable for mounting on Sports lighting tower. ( For detailed LED Fixture Specification please refer to SBD of this tender); LED Fixture makes : APEX LED Flood light Osram LED Flood light , LOKOZO LED Floodlight WIPRO LED floodlight GOLDWYNLED/Philips Flood Light Surya or equivalent Lux level of 500 Future augmentation to the tune of 1500 Lux if required rates as per LMR shall be applicable to the said wattage of lights with reference base of above quoted wattage. e.g 100 watts LED 200 watts LED 300 Watts LED 400 Watts LED
Supply Installation , testing and commissioning of 30 m high galvanized polygon tubular Sports Lighting Tower 7.5mm thick with max. 3 sections, 20 sided polygon, of S355 Grade as per BSEN 10025, galvanization as per BS EN ISO 1461, designed as per IS 875 part Ill, poles as per BS EN ISO 1461, c/w Head frame of GI Channel _ tube construction for mounting of 10 nos. to 15 nos Sports flood lights, c/w Single gear double drum (SGDD ) winch min, load of SWL 750 kgs, heavy duty motor with mechanical tripping facility, electrical Cable of EPR insulated, weather proof IP65 Junction box, SS 316 grade wire rope, lightening protection, LED twin aviation obstruction light of low intensity continuous burning RED colour type alongwith feeder pillar to function as local power panel for the Sports lighting tower in all respects. Drawings for GA of the S orts _Lighting tower and Foundation details to be enclosed with the Tender Bi For foundation calculation 10 SBC of SBC of 10 Mt to be considered ( It is the responsibility of the contractor executing the works to arrange for soil testing and SBC reports of ground conditions each sports lighting tower foundation location and revised foundation drawing from the Sports LightingTower manufacturer to be submitted for approval before starting of the foundation works) LOKOZO , Transrail and Wallmount Structure should be able to cater 1000 watt lights for maintaining 1500 LUX if in future notified
Supply Installation , testing and commissioning of 24 m high galvanized polygon tubular Sports Lighting Tower 7.5mm thick with max. 3 sections, 20 sided polygon, of S355 Grade as per BSEN 10025, galvanization as per BS EN ISO 1461, designed as per IS 875 part Ill, poles as per BS EN ISO 1461, c/w Head frame of GI Channel _ tube construction for mounting of 10 nos. to 15 nos Sports flood lights, c/w Single gear double drum (SGDD ) winch min, load of SWL 750 kgs, heavy duty motor with mechanical tripping facility, electrical Cable of EPR insulated, weather proof IP65 Junction box, SS 316 grade wire rope, lightening protection, LED twin aviation obstruction light of low intensity continuous burning RED colour type alongwith feeder pillar to function as local power panel for the Sports lighting tower in all respects. Drawings for GA of the S orts _Lighting tower and Foundation details to be enclosed with the Tender Bi For foundation calculation 10 SBC of SBC of 10 Mt to be considered ( It is the responsibility of the contractor executing the works to arrange for soil testing and SBC reports of ground conditions each sports lighting tower foundation location and revised foundation drawing from the Sports LightingTower manufacturer to be submitted for approval before starting of the foundation works) LOKOZO , Transrail and Wallmount Structure should be able to cater 1000 watt lights for maintaining 1500 LUX if in future notified
Supply Installation , testing and commissioning of 20 m high galvanized polygon tubular Sports Lighting Tower 7.5mm thick with max. 3 sections, 20 sided polygon, of S355 Grade as per BSEN 10025, galvanization as per BS EN ISO 1461, designed as per IS 875 part Ill, poles as per BS EN ISO 1461, c/w Head frame of GI Channel _ tube construction for mounting of 10 nos. to 15 nos Sports flood lights, c/w Single gear double drum (SGDD ) winch min, load of SWL 750 kgs, heavy duty motor with mechanical tripping facility, electrical Cable of EPR insulated, weather proof IP65 Junction box, SS 316 grade wire rope, lightening protection, LED twin aviation obstruction light of low intensity continuous burning RED colour type alongwith feeder pillar to function as local power panel for the Sports lighting tower in all respects. Drawings for GA of the S orts _Lighting tower and Foundation details to be enclosed with the Tender Bi For foundation calculation 10 SBC of SBC of 10 Mt to be considered ( It is the responsibility of the contractor executing the works to arrange for soil testing and SBC reports of ground conditions each sports lighting tower foundation location and revised foundation drawing from the Sports LightingTower manufacturer to be submitted for approval before starting of the foundation works) LOKOZO , Transrail and Wallmount Structure should be able to cater 1000 watt lights for maintaining 1500 LUX if in future notified
Foundations of 30mtr high mast poles 6mx6mx9m Dimension provided for estimation only. Contractor to furnish SBC report and foundation design for approval)
Foundations of 24mtr high mast poles 6mx6mx9m Dimension provided for estimation only. Contractor to furnish SBC report and foundation design for approval)
Foundations of 20mtr high mast poles 6mx6mx9m Dimension provided for estimation only. Contractor to furnish SBC report and foundation design for approval)
Ferruling
Galvanized nuts and bolts of sorts as required at site
Earthling of 9 mtr. Long ST poles using 8 SWG GI Wire
0.03 ACSR for jump ring of transformer on HT side
Aluminum Thimbles of sizes required for cables of different sizes used including crimping
25x3 mm GI strip for earthling extensions
Epoxy insulator of sizes required for earthling of DTR structure
12”x9” Danger plates for HT and LT notification
Painting of DTR frame and tapping point frame with two coats of red oxide and two coats of aluminum paint
Supply erection testing and commissioning of 70mm Sq aluminum conductor , armored XPLE three and a half core LT cable 1.1 KV grade of Havells , Polycab , Paramount , Sky tone make
50mm Sq Aluminum conductor , armored XLPE thee and a half core LT cable 1.1 KV grade of Havells, Polycab Paramount , Skytone make
25 mm sq Aluminum three cores LT cable 1.1 KV grade of Havells , Polycab , Paramount , Skytone Make
Trench of cable laying through 3” HDPE pipe including excavation laying of sand bed placing of layer of bricks ( cost of sand and bricks included) including metallic cable markers with grouting after every ten meters . The cable route marker should be of 45x45 angle iron 2.5 feet long with circular metallic disc 4” dia at the top with LT CABLE embossed on it. The route marker should be grouted 1 feet inside the concrete and 1.5 feet above ground with clearly legible marking
Supply & installation of 3mm thick octagonal pole having bottom dia of 175mm and top dia of 70mm thick
Supply & installation of 3,4mm thick octagonal pole having bottom dia of 360mm and top dia of 150mm thick
Foundation work for pole.
Foundation work for pole.
Supplying and fixing of special arm suitable for mounting Led Flood Lights
Supply and fixing of KESELEC SPARTA Flood light having 1151m/Watt or equivalent in Osram/Trilux/lokozo/surya
Supplying and fixing of
a).Main LT Panel Outdoor type
b). Sub Main LT Panel Outdoor type
c). P/f of 6-32 Amp. MCB complete with connections as req.
d). P/f of 4-pole connector 16 amp complete with connections as req.
Supplying, installation, Testing & Commissioning of 1.5x3C Copper flexible wire of approved made
Supplying/laying of corrugated PVC pipe 50mm
Supplying and fixing of GI Wire (8SWG)
P/Laying of armored aluminum conductor to be laid in cable trench. The job incl. all civil works and refilling after cable laying and removal/disposal of surplus earth.
a). 10mm 4 core armored aluminum conductor
b). 16mm 4 core armored aluminum conductor
c). 25mm 3.5 core armored aluminum conductor
d). 25mm 4 core armored aluminum conductor
e). 50mm 3.5 core armored aluminum conductor
Fabrication, Supply & Installation of outdoor Canopy suitable for main panel board and Servo Stabilizer with complete cement concrete foundation and locking arrangement complete job.
ESS ESS Enterprises Electronics
VALLEY ELECTRICAL INDUSTRIES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .