| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹10.0 L+₹57,050 (6.06%)Rejected-Finance 19 SAINIK COLONY BAIRAGARH BHOPAL MP 462 030 | BHOPAL | MADHYA PRADESH | 462030 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹10.0 L+₹60,888 (6.47%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹10.3 L+₹91,941 (9.77%)Rejected-Finance 53 SHANTI S SANIK COLONY BAIRAGARH BHOPAL MP 462 030 | BHOPAL | BHOPAL | MADHYA PRADESH | 462030 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹11.8 L+₹2.4 L (25.2%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
16 Sept 2020, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
REPAIR MAINT OF INTERNAL ELECTRIFICATION AND FIXTURES TO CERTAIN OFFRS/JCOS/OR MD ACCN AT BAIRAGARH UNDER GE BHOPAL
2020_MES_369738_1
8711/E8
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
BHOPAL
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE BHOPAL
₹30,000
Yes
17 Nov 2020
17 Aug 2020
18 Sept 2020
17 Aug 2020
16 Sept 2020
3 Sept 2020
Amount
Taking down carefully existing point wiring (any type viz. aluminum or copper) with wooden batten/surface PVC conduit (with its fittings)/PVC casing-capping or any other type for light, fan, power point (including switch, socket, ceiling rose, etc.) and making good disturbed surface of wall/ceiling to match with existing surface after necessary rewiring complete all as specified and directed.
M&L for point wiring for one light / fan / bell point/ one 3 pin 5 Amp socket outlet on independent board with 1.50 sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one one-way switch, drawn in & including non metallic rigid PVC conduit (ISI marked) medium grade not less than 20mm diameter with all conduit accessories in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 (except on ceiling for fan point only, surface casing capping will be used in lieu of concealed PVC conduit) including one run of 1.5 sqmm copper conductor FRLS as earth continuity wire connected to common earth dolly, sunk sheet steel terminal box made out of 1.20 mm thick GI/MS sheet for mounting of fittings like switches, sockets, fan regulators etc. with 3mm thick laminated hylum sheet cover complete all as specified and directed. [Make of Cable : Polycab/ L&T/ Havells] Note :(i) Wiring to be done as per approved colour code in IE rule. (ii) Rate includes chase cutting for concealed wiring.
All as per item No. 2.00 here-in-before but for one light point controlled by two 2 way switches, with FRLS cables of 1.5 sqmm complete all as specified and directed.
All as per BOQ item No.2.00 above, one 5 Amps socket outlet point controlled by one switch on same board with other switches complete all as specified and directed.
All as per item No. 2.00 here-in-before but wiring with 2.5 Sq mm FRLS mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
All as per item No. 2.00 here -in- before but wiring with 4.0 Sq mm FRLS mutistranded copper conductor cable for Geyser and AC point on independent board and with 4.0 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed. .
M&L for point wiring for one light / fan / bell point/one 3 pin 5 Amp socket outlet on independent board with 1.50 sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one one-way switch, drawn in existing concealed/surface conduit including one run of 1.5 sqmm copper conductor FRLS as earth continuity wire connected to common earth dolly by suitable lugs and 3mm thick laminated hylum sheet cover including taking old point wiring (any type without conduit) complete all as specified and directed. [Make of Cable : Polycab/ L&T/ Havells] Note : Wiring to be done as per approved colour code in IE rule.
All as per BOQ item No. 7.00 above, but for one light point controlled by two 2 way switches complete all as specified and directed.
All as per BOQ item No.7.00 above, one 5 Amps socket outlet point controlled by one switch on same board with other switches complete all as specified and directed.
All as per BOQ item No. 7.00 above, but wiring with 2.5 Sq mm copper cable for 5/15 amp switch socket combination on independent board and provision of 2.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
All as per item 7.00 herein before but wiring with 4.0 Sq mm FRLS mutistranded copper conductor cable for Geyser and AC point on independent board and with 4.0 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
M&L for point wiring for one light / fan / bell point/one 3 pin 5 Amp socket outlet on independent board with 1.5 Sqmm single core, multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLS cable drawn in & including PVC casing caping of 25 mm wide, with double locking type, ISI marked including all accessories casing caping as approved by EIC, with PVC 1.5 mm multi stranded insulated unsheathed FRLS copper wire, ISI marked of green colour for continous earth, including sunken box made out of 1.20 mm thick and not less than 60 mm in depth GI/MS/ prssed steel terminal box to be conclead in wall, duly painted with two coated of aluminium paint on internal surface and two coat of anti corrosive paint over external surface, including laminated hylum sheet cover, ISI marked of Make" Hylem" for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer complete all as specified and directed. Note : Wiring to be done as per arroved colour code. Make of Cable : Polycab/ L&T/ Havells
All as per item 12.00 herein before One light point controlled by two 2-way switches.
All as per BOQ item No.12.00 above, one 5 Amps socket outlet point controlled by one switch on same board with other switches complete all as specified and directed.
All as per item 12.00 herein before but wiring with 2.5 Sq mm FRLS mutistranded copper conductor cable for 5/15 amp switch socket combination on independent board and with 2.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
All as per item 12.00 herein before but wiring with 4.0 Sq mm FRLS mutistranded copper conductor cable for Geyser and AC point on independent board and with 4.0 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
S&F Switch piano, flush type, single pole, one way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Switch piano, flush type, single pole, two way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA PC series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Ceiling rose surface bakelite, three terminals, 240V, 50Hz, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Socket outlet multipurpose having provision for 2 & 3 pin, 6 Amp flush type, 240 volt AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Socket oulet, multipurpose, 2 in 1, 3 pin, 5 & 15 Amp, 240 volt, 50Hz, flush type, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Switch piano, one way, single pole, 16/20 Amp, 240 volt, 50Hz, flush type, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F ceiling fan regulator electronic steped type 240 V, AC 50 Hz single pole, 100 watts flush type complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings with & including LED lamp white 9 watt retrofit, 230 volts complete all as specified and directed. [MAKE FOR HOLDER:-ANCHOR (PENTA PC series)/ LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE] & LAMP : BAJAJ/PHILIPS/SYSKA]
S&F Bell, Ding Dong type, electric, single phase, 240 volt, AC complete all as specified and as directed. [MAKE:-ANCHOR / LEADER/ LEGRAND /HAVELLS as approved by GE]
S&F Bell push, flush type, 6 Amp piano type, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA PC series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
Taking down unserviceable sub main wiring including service connections, of any size and any description including conduit pipe complete all as specified and directed.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 4.0 sqmm nominal cross section area and drawing into and including rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 25mm external diameter and PVC insulated stranded copper conductor of 4.0 sqmm nominal cross section area as earth wire complete all as specified and directed. [Make of Cable : V-MARC/ Plaza/ Havells/Polycab as approved by GE] Note : (i) Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 4.0 sqmm cable, one run of 4.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 6.0 sqmm nominal cross section area and drawing into and including rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 25mm external diameter and PVC insulated stranded copper conductor of 6.0 sqmm nominal cross section area as earth wire complete all as specified and directed. [Make of Cable : V-MARC/ Plaza/ Havells/ Polycab as approved by GE] Note : (i) Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 6.0 sqmm cable, one run of 6.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 10 sqmm nominal cross section area and drawing into and including rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 25mm external diameter and PVC insulated stranded copper conductor of 10 sqmm nominal cross section area as earth wire complete all as specified and directed. [Make of Cable : V-MARC/ Plaza/ Havells/ Polycab as approved by GE] Note : (i) Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 10.0 sqmm cable, one run of 10.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 4.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 4.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in complete all as specified and directed by EIC. Make of Cable : V-MARC/ Plaza/ Havells/ Polycab as approved by GE
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 6.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in complete all as specified and directed by EIC. Make of Cable : V-MARC/ Plaza/ Havells/ Polycab as approved by GE
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 10.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in complete all as specified and directed by EIC. Make of Cable : V-MARC/ Plaza/ Havells/ Polycab as approved by GE
Taking down old unserviceable MCB DB of any size and capacity including wooden boards complete all as specified and directed.
S & F sheet metal enclosure for MCB, DB, VTPN 415 Volts 200 amps rated busbar 16 KA, 4 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 with MCB as incommer and MCB SP/TP in outgoing complete all as specified and directed. Make- Legrand/ Seimens/ Schinder/L&T.
S&F sheet metal enclosure for VT DB TPN, MCCB DB TPN 4 way, double door with 63 Amp, 16 KA,TP MCCB as incomer (Vertical type double door, 63 Amps MCCB rate inclusive) and suitable for SP/TP DB in outgoing, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed. Make- Legrand/ Seimens/ Schinder/L&T.
S&F sheet metal enclosure for VT DB TPN, MCCB DB TPN 6 way, double door with 100 Amp,25 KA,TP MCCB as incomer (Vertical type double door DB, 100 Amps MCCB rate inclusive)and suitable for SP/TP DB in outgoing, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 complete all as specified and directed. Make- Legrand/ Seimens/ Schinder/L&T.
S&F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 amps rated busbar 10 KA, 12 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed. Make- Legrand/ Seimens/ Schinder/L&T.
S&F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 amps rated busbar 10 KA, 8 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed. Make- Legrand/ Seimens/ Schinder/L&T.
S&F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 amps rated busbar 16 KA, 4 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed. Make- Legrand/ Seimens/ Schinder/L&T.
S&F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 2 way, single door without bus bar, enclosure made up of CRCA sheet steel RAL 9003 powder coated, IP 30 including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed. Make- Legrand/ Seimens/ Schinder/L&T.
S&F MCB SP, 240 volts, 10 KA breaking capacity, 'C' curve, of capacity 5 to 32 amps including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE: Siemens/ Legrand/ Schinder/L&T as approved by GE]
S&F MCB SPN, 240 volts, 10 KA breaking capacity, 'C' curve, of capacity 5 to 32 amps including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE: Siemens/ Legrand/ Schinder/L&T as approved by GE]
S&F MCB TPN 40 to 63 Amps, 10 KA breaking capacity, including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE: Siemens/ Legrand/ Schinder/L&T as approved by GE]
S&F in repair MCB SP 240 volts 5 to 32 Amps, 10 KA breaking capacity, 'C' Curve including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE: Siemens/ Legrand/ Schinder/L&T as approved by GE]
S&F in repair MCB SPN 5 to 32 amps 10 KA , 'C' Curve including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE: Siemens/ Legrand/ Schinder/L&T as approved by GE]
S&F in repair MCB TPN 40 to 63 Amps, 10 KA breaking capacity, including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE: Siemens/ Legrand/ Schinder/L&T as approved by GE]
S&F single pole and neutral enclosure with two pin and earth, plug and socket, suitable for single phase 240 V, complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking cap 10 KA, including industial plug top, complete all as specified and as directed. [MAKE: Siemens/ Legrand/ Schinder/L&T as approved by GE]
S&F in replacement High quality LED tube light fitting batten T8 type 20/22 Watt (reterofit type, T5 pattern, ) 240 V, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100Lm/W, short protecton & surge protection 2KV, 50K Burning hour with wide voltage protection 150-320 v complete all as specified and as directed. Make: Bajaj/ Philips/Wipro/Crompton/Havells.
S&F in replacement LED 20/22 Watt tube rod batton type T8, 240 Volt, with PF >0.95, efficacy >95 , colour temp 6500K complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed. Make: Bajaj/ Philips/Wipro/Crompton/Havells.
M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR-2009 Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by 15mm dia light grade GI pipe and watering pipe shall be 20mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed. NOTE :- (i) The concrete pit shall be PCC (1:3:6) type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) The unit rate includes the cost of GI pipe medium grade for protection of earth wire and 4mm dia earh lead wire upto 7.5 M. (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself.
S&F GI tubing light grade 40 mm dia with all fittings as required for passing through cables under floors, along the wall or along the pole, etc with suitable size M.S.flat iron clamps including necessary nut,bolt and washer or for protection of GI wire, etc including taking down old rusted pipe complete all as specified and directed.
S&F GI tubing light grade 50 mm dia with all fittings as required for passing through cables under floors, along the wall or along the pole, etc with suitable size M.S.flat iron clamps including necessary nut,bolt and washer or for protection of GI wire, etc including taking down old rusted pipe complete all as specified and directed.
S&F GI tubing light grade 15 mm dia with all fittings as required for passing through cables under floors, along the wall or along the pole, etc with suitable size M.S.flat iron clamps including necessary nut,bolt and washer or for protection of GI wire, etc including taking down old rusted pipe complete all as specified and directed.
Supply and fixing earth continuity conductor or main earthing lead of 4 mm GI wire laid in pipe/ fixed to wall on batton or recess or chases or buried in ground or drawn in conduit / pipe or any other indicated situation for loop earthing etc including jointing by using suitable size lugs, GI nuts, bolts and washer complete and all as specified and directed.
Supply and fixing switch socket combination 5-in-1, 5A/15 Amps, 6 pin, 240 volts controlled by one switch, flush type complete and all as specified and directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S & F bulk head luminare weather proof, including one No. LED lamp 9W and connecting with copper flexible three core 23/0.0076 and all necessary fittings complete and all as specified and directed.
M&L cutting PCC/floor/road for taking out/ laying of cable, GI earth wire etc in protection pipe and making good, including material as per existing after laying of pipe for cable protection, GI wire etc, size of trench not more than 0.30 x 0.30 m complete all as specified and directed.
Supply and fixing switch socket combination 5-in-1, 5A/15 Amps, 6 pin, 240 volts controlled by one switch, flush type, including taking out old unserviceable Switch socket combination complete and all as specified and directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/ HAVELLS as approved by GE]
S&F in replacemnt lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings with & including LED lamp white 9 watt retrofit, 230 volts complete all as specified and directed. [MAKE FOR HOLDER:-ANCHOR (PENTA PC series)/ LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE] & LAMP : BAJAJ/PHILIPS/SYSKA]
Taking down existing unserviceable fitting any type any size and S&F LED 10/9 Watt tube mirror light suitable length, 240 v, PF > 0.90, colour Temp 6500 K, suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core, and PVC round block white colour, 2 Nos for mounting of fitting complete all as specified & directed. Make :- Philips/ Crompton/Bajaj/Havells .
Supply, laying, fixing or passing through pipe, 1100 volt grade heavy duty cable with PVC insulated multi stranded alunimium conductor served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and over all PVC sheathed 10 Sqmm x 2 core nominal cross section in service connections in ulding taking down old cable complete all as specified and directed. [MAKE:- POLYCAB /HAVELLS INDIA LTD/ KEI/V-MARC as approved by GE]
Excavating in trenches, nott exceeding 1.5m wide and not exceeding 1.5m in depth for pole foundation, cable trench, etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed. at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection (8 cm below cable & 15 cm above cable) complete all as specified and directed. [Note:-Compacted/punned thickness shall be measured & paid]
Supplying and laying sub class 'B' bricks (modular) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed
S&F in replacement surface mounted economical LED panel light 2 ftx 2ft, 36 watt with high quality diffuser for uniform light, CRCA housing, Separate replaceable electronic driver, suitable for recess and surface, CRCA panel 36ECW including led lamp, nut, wire all connected accessories complete all as specified and directed. Make: Bajaj/ Philips/Wipro/Crompton/Havells.
S&F in replacement LED lamp 9 Watt, Pin type, retrofit type in existing fitting with necessary change in wiring complete all as specified and directed. Make: Bajaj/ Philips/Wipro/Crompton/Havells.
Deduct schedule of credit (calculation will be done off line) Rs.63731.00
SUNIL ENTERPRISE
H S ENTERPRISES
M/S Shanti Enterprises
M/s VIKAS TRADERS
UMESH ENTERPRISES
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .