| Sl No | Description | Qty | Unit | Insat Techno Services L2 | Phoenix International L1 |
|---|---|---|---|---|---|
| 1.00PART A ( Technical Specifications as Annexure E) | |||||
| 2.00 | SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF FIREWALL • Minimum Requirement Description
• The Proposed Firewall Vendor should be in the Leaders’ Magic Quadrant of the latest Gartner report for Network Firewall 2021. Report must be attached.
• Firewall appliance should be supplied with at least 4* 10GE SFP+,6*GE SFP, 12x GE RJ45 ports and dual power supply from dayone.
• Firewall Throughput should be at least 24 Gbps
• Firewall should have IPS throughput of 4 Gbps
• Firewall should have IPSec throughput of 10 Gbps
• Firewall should support 240000 new sessions per second or higher
• Firewall should support 2 Million concurrent sessions or higher
• Firewall should support minimum 200 IPSEC site-to-site VPN tunnels or higher.
• The Firewall solution should support NAT46, NAT64, NAT66 DNS64 & DHCPv6
• The proposed system shall be able to operate on either Transparent (bridge) mode to minimize interruption to existing network infrastructure or NAT/Route mode. Both modes can also be available concurrently using Virtual Contexts. Minimum 5 Virtual Firewall licenses to be provided with the solution from day one
• The physical interface shall be capable of link aggregation, otherwise known as the IEEE 802.3ad standard, allows the grouping of interfaces into a larger bandwidth 'trunk'. It also allows for high availability (HA) by automatically redirecting traffic from a failed link in a trunk to the remaining links in that trunk.
• The proposed system should have integrated Traffic Shaping functionality.
• The Firewall should have integrated SSL VPN solution to cater to 500 SSL VPN concurrent users.
• The Firewall and VPN module shall belong to product family which minimally attain Internet Computer Security Association (ICSA) Certification or equivalent.
• "The proposed system should support
• IPSEC VPN
• SSL VPN"
• The device support inbuilt hardware VPN acceleration
• The IPS capability shall minimally attain NSS Certification
• The Next Generation Firewall (FW + AVC + IPS ) throughput should be at least 3 Gbps for Mix / production traffic
• "The IPS detection methodologies shall consist of:
• Signature based detection using real time updated database
• Anomaly based detection that is based on thresholds"
• The IPS system shall have at least 11,000 signatures
• In event if IPS should cease to function, it will fail open by default and is configurable. This means that crucial network traffic will not be blocked and the Firewall will continue to operate while the problem is resolved
• IPS solution should have capability to protect against Denial of Service (DOS) and DDOS attacks. Should have flexibility to configure threshold values for each of the Anomaly. DOS and DDOS protection should be applied and attacks stopped before firewall policy look-ups.
• IPS signatures should have a configurable actions like terminate a TCP session by issuing TCP Reset packets to each end of the connection, or silently drop traffic in addition to sending a alert and logging the incident
• Signatures should a severity level defined to it so that it helps the administrator to understand and decide which signatures to enable for what traffic (e.g. for severity level: high medium low)
• The threat prevention (FW + AVC + IPS + Antivirus /Antimalware) throughput should be at least 3 Gbps on Mix / Production traffic
• The proposed system should be able to block, allow or monitor only using AV signatures and file blocking based on per firewall policy based or based on firewall authenticated user groups with configurable selection of the following services: HTTP, HTTPS, SMTP, SMTPs, POP3, POP3s, IMAP, FTP etc
• The Firewall should support CDR functionality to strip suspected active content from files and deliver a sanitised file in realtime by removing the malicious content from the files received.
• The proposed system should be able to block or allow oversize file based on configurable thresholds for each protocol types and per firewall policy.
• The proposed system should have integrated Web Content Filtering solution without external solution, devices or hardware modules.
• The proposed solution should be able to enable or disable Web Filtering per firewall policy or based on firewall authenticated user groups for both HTTP and HTTPS traffic.
• "The proposed system shall provide web content filtering features:
• which blocks web plug-ins such as ActiveX, Java Applet, and Cookies.
• Shall include Web URL block
• Shall include score based web keyword block
• Shall include Web Exempt List"
• The proposed system shall be able to queries a real time database of over 110 million + rated websites categorized into 70+ unique content categories.
• The proposed system shall have the ability to detect, log and take action against network traffic based on over 3500 application signatures
• The application signatures shall be manual or automatically updated
• The administrator shall be able to define application control list based on selectable application group and/or list and its corresponding actions
• The proposed system shall allow administrator to prevent sensitive data from leaving the network. Administrator shall be able to define sensitive data patterns, and data matching these patterns that will be blocked and/or logged when passing through the unit.
• The proposed system shall have built-in high availability (HA) features without extra cost/license or hardware component
• The device shall support stateful session maintenance in the event of a fail-over to a standby unit.
• High Availability Configurations should support Active/Active or Active/ Passive
• 3 year license of Firewall, IPS,Application Control, URL filtering, Anti-Bot, APT, Gateway Antivirus etc, Antispam , 24*7 Support,RMA & Advance hardware Replacement should be quoted with the solution | 1 | NO. | 18,65,500 ₹18,65,500 | 16,97,000 ₹16,97,000 Lowest |
| 3.00 | SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF L3 CORE SWITCH 20 10G SFP+ ports, 4 10GBASE-T/SFP+ combo ports
• Switch should 1RU with 20-port 1G/10G SFP+, 4-port 10Base-T/SFP+ combo Ports.
• Layer 3 10GbE Managed Switch with fully populated (included) with Required 4 SFP+,8 SFP and 8 1000BASE-T Copper SFP Transceiver/Module and Two AC hot-swappable power modules for 1+1 redundancy and load sharing.
• All SFP+ and SFP Transceiver/Module should be single mode upto 10 km
• The switch should be stackable with physical stacking or MLAG or Virtual Switching System (VSS) or Equivalent technology.
• Should have RJ-45 console ports for out-of-band CLI management.
• Should support One 10/100/1000BASE-T RJ-45 Ethernet for out-of-band IP management.
• Should support One USB Port for easy management for images and configuration files, that can be copied to and from the NVRAM of the Switch.
• Switch should be stackable
• Switch should be IPv6 ready
• Power Supply & FAN - Switch should support Internal Hot swappable PSU and Fiber Modules
• Performance
• The Switch have 450 Gbps Switching Capacity, and forwording rate 350 Mpps, for Higher switching functionalaty.
• MAC Address Table should be Up to 46K entries or More.
• Min 4K static VLAN groups and Min 4K VIDs
• Packet Buffer Memory 4 MB
• All Functionalities of Switch shall be IPv6 compliant and it should work on IPv6 Platform without any additional hardware/ software.
• IEEE Standards
• Should have IEEE Standards of Ethernet: IEEE 802.1D, 802.1s, 802.1w, 802.1x, 802.3ad, 802.3x, 802.1p, 802.1Q, 802.3u, 802.3ab, 802.3z.
• Switch should support STP/MSTP/RSTP and ERPS for support less than 50 Millisecond convergence (G.8032 v1/v2) Protocol support and FlexLink.
• Switch Should Supports OSPFv2/v3, BGP4+, IEEE 802.3ah Ethernet Link OAM, IEEE 802.1ag, ITU-T Y.1731 Service OAM, Multicast VLAN.
• Security
• Switch should support Port isolation, Port security, and “IP+MAC+port” binding, DHCP Snooping, IP source guard, IEEE 802.1x, Radius and Tacacs+, DDoS, TCP’s SYN Flood, UDP Flood, etc, Broadcast/multicast/unknown unicast storm-control, Supports encryption MD5, etc.
• Switch Should Support Flow Control, Spanning Tree Protocol, 802.1D STP, 802.1w RSTP, 802.1s MSTP, Root Guard, Loop Guard, Jumbo Frame
• Switch Should Support 802.1AX Link Aggregation, 8 groups per device, 8 ports per group, ERPS (Ethernet Ring Protection Switching)
• Switch Should Support Port mirroring Supports one-to-one, many-to-one, Supports mirroring for Tx/Rx/both, Supports 4 mirroring groups, VLAN mirroring, L2 protocol tunneling, Loopback Detection (LBD)
• Routing Protocols
• Should support Static Route, Default Route, OSPF for IPv4 and IPv6, RIPv1/v2, RIPng, and Policy-based Route (PBR) for IPv4 and IPv6, support for BGPv4, VRRPv3, IPv6 Neighbor Discovery (ND)
• Should suppoort Static, ISATAP and 6to4 IPv6 Tunneling.
• L3 Multicasting - IGMP v1/v2/v3, IGMP & MLD Snooping, Multicast Table Size: Up to 1K, PIM-SM IPv4/IPv6, PIM-SM, MSDP.
• Should support 802.1p Quality of Service with 8 queues per port
• Should support Queue Handling with Strict Priority Queue, Weighted Round Robin, Deficit Round Robin (DRR), SPQ + WRR and WFQ.
• Should support QoS based on 802.1p Priority Queues, MAC address, IP address, DSCP, VLAN, TCP/UDP port, Switch port.
• Should support Ingress and Egress ACL, Time-based ACL.
• Should support Access Control List based on 802.1p priority, MAC address, VLAN, TCP/UDP port number, DSCP, IP addres.
• Should support 802.3ah Ethernet link OAM and 802.1ag Connectivity Fau+B2lt Management (CFM) and Y.1731 OAM.
• Management
• Secure Web based management (On https) through NMS or Full featured CLI, TELNET Access.
• Switch should support AAA using RADIUS must be available, Identity-driven Policy (VLAN/ACL/QoS) Assignment, Guest VLAN
• SSH based management (SSH v2). IEEE 802.3ah Ethernet link OAM, IEEE 802.1ag, ITU-T Y.1731
• The switch should support SNMP V2c and V3, and RMONv1 and RMONv2 Support
• Time synchronization using Network time protocol must be available.
• Config/image upload and download from TFTP/FTP server shall be available.
• POWER CHARACTERISTICS
• AC Voltage: 100 to 240 V AC, 50Hz ± 10%
• Operating temperature: 0°C to 45 °C and Relative Humidity: 10% to 95% Non-condensing
• Note
• Switches and Fiber Modules should be from Same OEM
• Switch should be supplied with the all necessary components like Power cord, Rack-mount bracket, Installation Guide, etc. and necessary software image file to fulfil all above mention feature set from day 1.
• OEM Should be International certification for the ISO 45001 Health and Safety Management System, Information Security Management System: ISO 27001, ISO 9001 Quality Management System, ISO 14001 Environmental Management System, and ISO 14064-1 Greenhouse Gas Inventory Standards. | 1 | NO. | 7,24,500 ₹7,24,500 Lowest | 7,99,000 ₹7,99,000 |
| 4.00 | SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF LAYER 3 STACKABLE MANAGED SWITCH
• Proposed Switch should have at least • 24 x 10/100/1000BASE-T ports, 2 x 10GBASE-T ports and 4 x 10G SFP+ ports
• 2 SFP+ Single modeTransceiver/Module should be included upto 10 km
• Switch should Support Internal/External Redundant Power Supply.
• Switch shall have SD Card slot/USB/External flash for easy file store & restoration like firmware, configuration file, boot image, syslog etc.
• RJ-45/ USB mini console port, port,RJ-45 Management Port.
• Switch shall have 6 kV surge protection on all RJ-45 access ports
• Switching Capacity should be 200 Gbps & Packet Forwarding rate should be 160 Mpps.
• The Switch shall support Min. 16K Mac address
• The Switch shall be able to do Physical Stack min 8 units per stack or more with 80 Gbps or more stacking bandwidth.
• The Switch shall be able to do Virtual stacking/clustering of up to 32 units per IP.
• The Switch Should support Jumbo Frame (up to 8K Bytes).
• The LAN switch shall have IEEE 802.1Q VLAN encapsulation and should support 4k Vlans.
• It shall have support for Detection of Unidirectional links and to disable them to avoid problems such as spanning tree loops
• It shall support 802.1v Protocol-based VLAN
• Should support MAC based Vlans
• Should support GVRP or equivalent,Private Vlan or equivalent,Subnet Vlan or equivalent, Voice Vlan and QinQ (port based qinq and selective qinq).
• Multicast VLAN to allow multiple VLANs to receive the same multicast traffic
• Switch should have support for below Spanning Tree protocol Standards: 802.1D STP, 802.1w RSTP, 802.1s MSTP
• The Switch should have 802.1AX Link Aggregation Up to 30 groups per device.
• Port Mirroring One to one/Many to One, Flow based mirroring & VLAN Mirroring
• Switch shall support ITU-T G.8032 Ethernet Ring Protection Switching to provide protection for Ethernet traffic in a ring topology, while ensuring that no loops are within the ring at the Ethernet layer
• The Switch shall have the intelligence to detect the loop occurring from the unmanaged network segment
• Switch should support Static routing for IPv4 and IPv6, RIP for IPv4 and RIPng for IPv6, OSPF
• Switch should support PIM-SM,PIM-DM,PIM-SDM,PIM-SMv6,DVMRP v3 and MSDP
• Should have policy based routing.
• Route Redistribution support
• Should support VRRP v2 & V3.
• Should support Bidirectional Forwarding Detection
• Class of service shall be based on Switch port, DSCP, Vlan ID,TCP/UDP port, Protocol type,802.1p queues, IPv4/v6 address, IPv6 flow label & User defined packet content
• Broadcast and Multicast traffic/storm control
• Weighted Random Early Detection (WRED) for congestion control
• 802.3ah Ethernet Link OAM
• 802.1ag Connectivity Fault Management (CFM)
• Switch shall support ITU-T Y.1731
• Optical Transceiver Digital Diagnostic Monitoring (DDM) & Dying gasp
• IEEE 802.1X Port Based Access control and Host based Access control and Guest Vlan
• It shall support RADIUS/TACACS+ authentication to enable centralized control of the switch and restrict unauthorized users from altering the configuration.
• It shall have IP-MAC-Port binding
• Switch should be able to authenticate and access control based on MAC and web (Http or Https)
• BPDU Attack Protection, ARP protection, IP Source Guard, Dynamic ARP Inspection and DOS Attack Prevention
• It shall support for SSHv2, SNMPv3 to provide network security by encrypting administrator traffic
• It shall support Trivial File Transfer Protocol (TFTP) to reduce the cost of administering software upgrades by downloading from a centralized location.
• It shall support Network Timing Protocol NTP to provide an accurate and consistent timestamp to all intranet switches.
• It shall support SNMPv1, SNMPv2c, and SNMPv3 and Telnet interface to deliver comprehensive in-band management, and a CLI-based management console to provide detailed out-of-band management
• Switch should be supplied with the all-necessary components like Power cord, Rack-mount bracket, Installation Guide, etc. and necessary software image file to fulfil all above-mentioned feature set from day 1. | 4 | NO. | 1,52,000 ₹6,08,000 Lowest | 1,67,000 ₹6,68,000 |
| 5.00 | SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF LAYER 2 NON-POE GIGABIT SMART MANAGED SWITCH
• Switch with at least 24 X 10/100/1000 Mbps Ports and COMBO Ports (10/100/1000 or 100/1000 SFP
• Switch Should Support Link status detection, Port and LED shut-off, System hibernation.
• Switching capacity should be 50 Gbps or higher or non-blocking architecture.
• Switch packet forwarding rate should be 40 Mpps or higher or non-blocking architecture.
• Switch MAC table should be at least 6K or higher.
• Power input should be 100 to 240 VAC, 50/60 Hz, internal power supply. Power Saving (Green)
• Operating temperature should be -5 degree Celsius to +50 degree Celsius.
• EMI Certificate - CE, FCC/IEC and SAFETY Certificate - CB/ UL.
• Switch Software Specification
• Should support Head of Line blocking prevention for lower latency and better performance.
• Support Jumbo Frame up to 6K Bytes or higher.
• Link Aggregation LACP 802.3ad: Minimum 8 groups per device and 8 ports per group
• Port Mirroring: One-to-One / Many-to-One
• Switch Should Support Access Control List based on (ACL's) 802.1p priority, VLAN, MAC address, Ether type, IP address, DSCP, Protocol type, TCP/UDP port number, IPv6 Traffic Class, Max. ACL Profiles
• Should have 802.1D STP, 802.1w RSTP and 802.1s MSTP Spanning Tree Protocol.
• Should support Spanning tree Root restriction.
• Should support Loopback detection (LBD) to detect the loop created by a specific port.
• Should support Multicast Filtering to filters or forward all unregistered groups.
• Switch should support IEEE 802.1Q VLAN tagging for Ethernet frames.
• Different type of VLAN like Port based, Auto Surveillance, Auto Voice, Asymmetric Vlan etc. should be available for configuration.
• Switch should support QoS (quality of service) IEEE 802.1P for traffic prioritization. It should support 4 queues per port.
• Different type of QoS priority like Strict Priority Queue and Weighted Round Robin.
• Port based ingress / egress rate limit function should be available with limit in increments as low as 8 Kbps
• Switch should support Neighbour Discovery (ND) protocol for IPv6.
• Switch should support to create at least 4 IP interface.
• Support at least 100 rules shared by IPv4, MAC, and IPv6 & Each rule can only be associated with a single port.
• Should support port security to secures the access port based on MAC address.
• should have broadcast, multicast, and unicast storm control to prevents faulty end stations from degrading overall systems performance.
• Support Traffic Segmentation to restricted traffic flow from a single or group of ports, to another group of ports.
• Should have SSH and SSL for IPv4 and IPv6.
• Require prevention of DoS attacks, which include Land, TCP Null Scan, TCP Xmas Scan and TCP SYNFIN.
• Should support 802.1X port-based authentication.
• Should support ARP spoofing prevention.
• Should support DHCP snooping and DHCP server screening.
• Switch should be able to create a binding table for IP + MAC + Port to prevents a malicious user from spoofing or to restrict the unauthorized users.
• Should support 802.1X RADIUS and local server database authentication.
• Should have option to check the status of copper cables using the cable-diagnostics time domain reflectometer (TDR).
• Able to manage trough Web-GUI, CLI, Telnet & SNMP
• Should support SNMP v1, v2c, v3 and SNMP Traps and Remote Monitoring (RMON).
• Should have dual Image support to reduced down time for the switches.
• Should have SNTP/NTP protocol for time synchronization.
• Should support Link Layer Discovery Protocol (LLDP) and LLDP-MED.
• Switches and Fiber Modules should be from Same OEM
• Switch should be supplied with the all-necessary components like Power cord, Rack-mount bracket, Installation Guide, etc. and necessary software image file to fulfil all above-mentioned feature set from day 1. | 20 | NO. | 32,500 ₹6,50,000 | 24,950 ₹4,99,000 Lowest |
| 6.00 | SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 24 PORT FAST ETHERNET UNMANAGED POE SWITCH
• Features
• 24 10/100/1000 Mbps Ethernet ports
• Full/half-duplex for Ethernet/Fast Ethernet/Gigabit
• 2 SFP Uplink"
• Functions
• VLAN
• EXTEND
• PoE
• QoS"
• PoE Functionality
• 24 PoE ports
• IEEE 802.3af/at compliant
• 240W total power budget
• Up to 30 W power output per PoE port"
• Standards
• IEEE 802.3u, Fast Ethernet standards • IEEE 802.3af/at, Ethernet power supply POE standard
• IEEE 802.3ab, Gigabit Ethernet standards • IEEE 802.3az, EEE, Energy efficient Ethernet standard
• IEEE 802.3x, Full-duplex Ethernet data link layers • IEEE 802.3z, Gigabit Ethernet Fiber-optic standard"
• Auto MDI/MDI-X adjustment on all ports
• Lighting Protection • 6KV
• Switching Fabric • 50 Gbps
• Transmission Method • Adopt Store-and-forward.
• Data Transfer Rates Gigabit Ethernet 1000 Mbps, Ethernet 100 Mbps
• Packet Filtering / Forwarding Rates "10M port maximum 14800pps.
• 100M port maximum 148800pps
• 1000M port maximum 1488000pps"
• PoE Standards IEEE 802.3af, IEEE 802.3at
• PoE-Capable Ports Port 1 - 24 (Port 1 - 8 PoE can support up to 250m @ 10Mbps with Extend enabled)
• Power Budget 250W (30 W max. per PoE port)
• Temperature Operating: 0 to 40 ˚C (32 to 104 ˚F)
• Certification EMI/EMC, CE | 6 | NO. | 35,500 ₹2,13,000 | 32,450 ₹1,94,700 Lowest |
| 7.00 | SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 16 PORT FAST ETHERNET UNMANAGED POE SWITCH
• 16 10/100/1000 BASE-T ports • 2 SFP"
• IEEE 802.3u,FastEthernet standard • IEEE 802.3af/at ,Ethernet power supply POE• IEEE 802.3ab,Gigabit Ethernet standards • IEEE 802.3az ,EEE, Energy efficient Ethernet• IEEE 802.3x, Full-duplex Ethernet data link layers • IEEE 802.3z ,Gigabit Ethernet fiber-optic
• Media Interface Exchange • Auto MDI/MDI-X adjustment on all ports
• Lighting Protection • 6KV
• Switching Fabric • 36 Gbps
• Transmission Method Adopt Store-and-forward
• Data Transfer Rates Gigabit Ethernet 1000 Mbps Ethernet 100Mbps
• Packet Filtering / Forwarding Rates 10M port maximum 14800pps, 100M port maximum , 148800pps 1000M port, maximum 1488000pps
• PoE Standards IEEE 802.3af, IEEE 802.3at
• PoE-Capable PortsPort 1 - 16 (Port 1 - 8 PoE can support up to 250m @ 10Mbps with Extend enabled)
• Power Budget 150W (30 W max. per PoE port) | 18 | NO. | 21,750 ₹3,91,500 Lowest | 24,000 ₹4,32,000 |
| 8.00 | SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF NETWORK VIDEO RECORDER (64-CH) NVR
• IP video input 64-ch
• Incoming bandwidth NVR Shall Support 300 Mbps or better
• Outgoing bandwidth NVR Shall Support 240 Mbps or better
• Recording resolution NVR Shall Support up to 12 MP resolution or higher
• HDMI output resolution NVR Shall Support 4K (3840 × 2160)
• Synchronous playback NVR Shall Support 16-ch playback
• Analytics Face picture comparison (4-ch face picture comparison alarm), human face capture
• (1-ch human face capture ), face picture search
• Face picture library Up to 16 face picture libraries, with up to 10,000 face pictures in total
• Network protocols TCP/IP, DHCP, DNS, DDNS, NTP, SMTP, NFS, iSCSI, UPnP™, HTTPS
• SATA NVR Shall Support 8 SATA interface
• Capacity NVR Shall Support up to 10 TB capacity for each HDD
• eSATA 1 eSATA interface
• Network interface 2, RJ-45 10/100/1000 Mbps self-adaptive Ethernet interface
• USB interface 2 × USB 2.0, 1 × USB 3.0
• Two-way audio NVR Shall Support1-ch, RCA
• Alarm in/out 16/8
• Working temperature 0 °C to 50 °C
• Certifications CE, FCC, BIS | 4 | NO. | 1,22,350 ₹4,89,400 Lowest | 1,33,500 ₹5,34,000 |
| 9.00 | SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF BULLET CAMERA 5 MP 40 METER IR
• Parameters Value
• Image Sensor 1/2.7″ Progressive Scan CMOS
• Min. Illumination Color: 0.01 Lux @(F1.2; AGC ON)
• Max. Resolution 2560 × 1920 or better
• WDR WDR should be 120dB or higher
• Focal length 4 mm/6mm
• IR Range Camera Shall Support Up to 40 m IR or better
• Behavior Analysis Line crossing detection, intrusion detection
• Region of Interest Camera Shall Support 1 region
• Image Enhancement BLC, HLC, 3D DNR
• Protocols TCP/IP, ICMP, HTTP, HTTPS, FTP, DHCP, DNS, DDNS, RTP, RTSP, NTP, IPv4, IPv6
• Simultaneous Live View Up to 6 channels
• User Up to 32 users
• Communication Interface 1 RJ45 10M/100M
• Operating Conditions -30 °C to 60 °C
• Protection Level IP67
• Certifications CE, FCC, BIS" | 200 | NO. | 12,200 ₹24,40,000 Lowest | 12,850 ₹25,70,000 |
| 10.00 | SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF DOME CAMERA 5 MP 40 METER IR
• Parameters Value
• Image Sensor 1/2.7"" Progressive Scan CMOS
• Min. Illumination Color: 0.005 Lux @ (F1.6, AGC ON)
• Max. Resolution 2560 × 1920 @20fps or better
• WDR WDR should be 120dB or higher
• Focal length 2.8 mm/4mm
• IR Range Camera Shall Support Up to 40 m IR range
• Behavior Analysis Line crossing detection, intrusion detection
• Region of Interest Camera Shall Support 1 region
• Image Enhancement BLC, HLC, 3D DNR
• Protocols TCP/IP, ICMP, HTTP, HTTPS, FTP, DHCP, DNS, DDNS, RTP, RTSP, RTCP, NTP, SSL/TLS
• Simultaneous Live View Up to 6 channels
• User Up to 32 users
• Communication Interface 1 RJ45 10 M/100 M
• On-Board Storage Camera Shall Support up to 256 GB or more
• Alarm Camera Shall Support 1 input, 1 output alarm
• Operating Conditions -30 °C to 60 °C
• Protection Level Camera Shall Support IP67, IK10
• Certifications CE, FCC, BIS | 30 | NO. | 12,200 ₹3,66,000 Lowest | 12,850 ₹3,85,500 |
Tender Value
₹1.6 Cr
EMD Value
₹3.2 L
Closing Date
24 Nov 2023, 12:00 pmClosed
Executive Engineer MHD, Srinagar
office of the Executive Engineer MHD, Srinagar
SITC of Closed Circuit Television Surveillance System, LAN System, and Firewall, along with 2 Years CMC post warranty period, and, 6 Months Operation, at A) Main Campus B) Library Block (Main Campus), of Govt Dental College
2023_PWDJK_235084_1
MHD/TS /2023-24/122/e-tendering Dated28.10.2023
Open Tender
Security System
Item Wise
60 days
Govt Dental College Srinagar
As detailed in NIT
6 documents required · 6 mandatory
₹4,000
Superintending Engineer Mand H Circle Kmr
₹3.2 L
4 Dec 2023
28 Oct 2023
24 Nov 2023
28 Oct 2023
24 Nov 2023
30 Oct 2023
30 Oct 2023 - 16 Nov 2023
Amount
PART A ( Technical Specifications as Annexure E)
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF L3 CORE SWITCH 20 10G SFP+ ports, 4 10GBASE-T/SFP+ combo ports • Switch should 1RU with 20-port 1G/10G SFP+, 4-port 10Base-T/SFP+ combo Ports. • Layer 3 10GbE Managed Switch with fully populated (included) with Required 4 SFP+,8 SFP and 8 1000BASE-T Copper SFP Transceiver/Module and Two AC hot-swappable power modules for 1+1 redundancy and load sharing. • All SFP+ and SFP Transceiver/Module should be single mode upto 10 km • The switch should be stackable with physical stacking or MLAG or Virtual Switching System (VSS) or Equivalent technology. • Should have RJ-45 console ports for out-of-band CLI management. • Should support One 10/100/1000BASE-T RJ-45 Ethernet for out-of-band IP management. • Should support One USB Port for easy management for images and configuration files, that can be copied to and from the NVRAM of the Switch. • Switch should be stackable • Switch should be IPv6 ready • Power Supply & FAN - Switch should support Internal Hot swappable PSU and Fiber Modules • Performance • The Switch have 450 Gbps Switching Capacity, and forwording rate 350 Mpps, for Higher switching functionalaty. • MAC Address Table should be Up to 46K entries or More. • Min 4K static VLAN groups and Min 4K VIDs • Packet Buffer Memory 4 MB • All Functionalities of Switch shall be IPv6 compliant and it should work on IPv6 Platform without any additional hardware/ software. • IEEE Standards • Should have IEEE Standards of Ethernet: IEEE 802.1D, 802.1s, 802.1w, 802.1x, 802.3ad, 802.3x, 802.1p, 802.1Q, 802.3u, 802.3ab, 802.3z. • Switch should support STP/MSTP/RSTP and ERPS for support less than 50 Millisecond convergence (G.8032 v1/v2) Protocol support and FlexLink. • Switch Should Supports OSPFv2/v3, BGP4+, IEEE 802.3ah Ethernet Link OAM, IEEE 802.1ag, ITU-T Y.1731 Service OAM, Multicast VLAN. • Security • Switch should support Port isolation, Port security, and “IP+MAC+port” binding, DHCP Snooping, IP source guard, IEEE 802.1x, Radius and Tacacs+, DDoS, TCP’s SYN Flood, UDP Flood, etc, Broadcast/multicast/unknown unicast storm-control, Supports encryption MD5, etc. • Switch Should Support Flow Control, Spanning Tree Protocol, 802.1D STP, 802.1w RSTP, 802.1s MSTP, Root Guard, Loop Guard, Jumbo Frame • Switch Should Support 802.1AX Link Aggregation, 8 groups per device, 8 ports per group, ERPS (Ethernet Ring Protection Switching) • Switch Should Support Port mirroring Supports one-to-one, many-to-one, Supports mirroring for Tx/Rx/both, Supports 4 mirroring groups, VLAN mirroring, L2 protocol tunneling, Loopback Detection (LBD) • Routing Protocols • Should support Static Route, Default Route, OSPF for IPv4 and IPv6, RIPv1/v2, RIPng, and Policy-based Route (PBR) for IPv4 and IPv6, support for BGPv4, VRRPv3, IPv6 Neighbor Discovery (ND) • Should suppoort Static, ISATAP and 6to4 IPv6 Tunneling. • L3 Multicasting - IGMP v1/v2/v3, IGMP & MLD Snooping, Multicast Table Size: Up to 1K, PIM-SM IPv4/IPv6, PIM-SM, MSDP. • Should support 802.1p Quality of Service with 8 queues per port • Should support Queue Handling with Strict Priority Queue, Weighted Round Robin, Deficit Round Robin (DRR), SPQ + WRR and WFQ. • Should support QoS based on 802.1p Priority Queues, MAC address, IP address, DSCP, VLAN, TCP/UDP port, Switch port. • Should support Ingress and Egress ACL, Time-based ACL. • Should support Access Control List based on 802.1p priority, MAC address, VLAN, TCP/UDP port number, DSCP, IP addres. • Should support 802.3ah Ethernet link OAM and 802.1ag Connectivity Fau+B2lt Management (CFM) and Y.1731 OAM. • Management • Secure Web based management (On https) through NMS or Full featured CLI, TELNET Access. • Switch should support AAA using RADIUS must be available, Identity-driven Policy (VLAN/ACL/QoS) Assignment, Guest VLAN • SSH based management (SSH v2). IEEE 802.3ah Ethernet link OAM, IEEE 802.1ag, ITU-T Y.1731 • The switch should support SNMP V2c and V3, and RMONv1 and RMONv2 Support • Time synchronization using Network time protocol must be available. • Config/image upload and download from TFTP/FTP server shall be available. • POWER CHARACTERISTICS • AC Voltage: 100 to 240 V AC, 50Hz ± 10% • Operating temperature: 0°C to 45 °C and Relative Humidity: 10% to 95% Non-condensing • Note • Switches and Fiber Modules should be from Same OEM • Switch should be supplied with the all necessary components like Power cord, Rack-mount bracket, Installation Guide, etc. and necessary software image file to fulfil all above mention feature set from day 1. • OEM Should be International certification for the ISO 45001 Health and Safety Management System, Information Security Management System: ISO 27001, ISO 9001 Quality Management System, ISO 14001 Environmental Management System, and ISO 14064-1 Greenhouse Gas Inventory Standards.
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF LAYER 2 NON-POE GIGABIT SMART MANAGED SWITCH • Switch with at least 24 X 10/100/1000 Mbps Ports and COMBO Ports (10/100/1000 or 100/1000 SFP • Switch Should Support Link status detection, Port and LED shut-off, System hibernation. • Switching capacity should be 50 Gbps or higher or non-blocking architecture. • Switch packet forwarding rate should be 40 Mpps or higher or non-blocking architecture. • Switch MAC table should be at least 6K or higher. • Power input should be 100 to 240 VAC, 50/60 Hz, internal power supply. Power Saving (Green) • Operating temperature should be -5 degree Celsius to +50 degree Celsius. • EMI Certificate - CE, FCC/IEC and SAFETY Certificate - CB/ UL. • Switch Software Specification • Should support Head of Line blocking prevention for lower latency and better performance. • Support Jumbo Frame up to 6K Bytes or higher. • Link Aggregation LACP 802.3ad: Minimum 8 groups per device and 8 ports per group • Port Mirroring: One-to-One / Many-to-One • Switch Should Support Access Control List based on (ACL's) 802.1p priority, VLAN, MAC address, Ether type, IP address, DSCP, Protocol type, TCP/UDP port number, IPv6 Traffic Class, Max. ACL Profiles • Should have 802.1D STP, 802.1w RSTP and 802.1s MSTP Spanning Tree Protocol. • Should support Spanning tree Root restriction. • Should support Loopback detection (LBD) to detect the loop created by a specific port. • Should support Multicast Filtering to filters or forward all unregistered groups. • Switch should support IEEE 802.1Q VLAN tagging for Ethernet frames. • Different type of VLAN like Port based, Auto Surveillance, Auto Voice, Asymmetric Vlan etc. should be available for configuration. • Switch should support QoS (quality of service) IEEE 802.1P for traffic prioritization. It should support 4 queues per port. • Different type of QoS priority like Strict Priority Queue and Weighted Round Robin. • Port based ingress / egress rate limit function should be available with limit in increments as low as 8 Kbps • Switch should support Neighbour Discovery (ND) protocol for IPv6. • Switch should support to create at least 4 IP interface. • Support at least 100 rules shared by IPv4, MAC, and IPv6 & Each rule can only be associated with a single port. • Should support port security to secures the access port based on MAC address. • should have broadcast, multicast, and unicast storm control to prevents faulty end stations from degrading overall systems performance. • Support Traffic Segmentation to restricted traffic flow from a single or group of ports, to another group of ports. • Should have SSH and SSL for IPv4 and IPv6. • Require prevention of DoS attacks, which include Land, TCP Null Scan, TCP Xmas Scan and TCP SYNFIN. • Should support 802.1X port-based authentication. • Should support ARP spoofing prevention. • Should support DHCP snooping and DHCP server screening. • Switch should be able to create a binding table for IP + MAC + Port to prevents a malicious user from spoofing or to restrict the unauthorized users. • Should support 802.1X RADIUS and local server database authentication. • Should have option to check the status of copper cables using the cable-diagnostics time domain reflectometer (TDR). • Able to manage trough Web-GUI, CLI, Telnet & SNMP • Should support SNMP v1, v2c, v3 and SNMP Traps and Remote Monitoring (RMON). • Should have dual Image support to reduced down time for the switches. • Should have SNTP/NTP protocol for time synchronization. • Should support Link Layer Discovery Protocol (LLDP) and LLDP-MED. • Switches and Fiber Modules should be from Same OEM • Switch should be supplied with the all-necessary components like Power cord, Rack-mount bracket, Installation Guide, etc. and necessary software image file to fulfil all above-mentioned feature set from day 1.
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 24 PORT FAST ETHERNET UNMANAGED POE SWITCH • Features • 24 10/100/1000 Mbps Ethernet ports • Full/half-duplex for Ethernet/Fast Ethernet/Gigabit • 2 SFP Uplink" • Functions • VLAN • EXTEND • PoE • QoS" • PoE Functionality • 24 PoE ports • IEEE 802.3af/at compliant • 240W total power budget • Up to 30 W power output per PoE port" • Standards • IEEE 802.3u, Fast Ethernet standards • IEEE 802.3af/at, Ethernet power supply POE standard • IEEE 802.3ab, Gigabit Ethernet standards • IEEE 802.3az, EEE, Energy efficient Ethernet standard • IEEE 802.3x, Full-duplex Ethernet data link layers • IEEE 802.3z, Gigabit Ethernet Fiber-optic standard" • Auto MDI/MDI-X adjustment on all ports • Lighting Protection • 6KV • Switching Fabric • 50 Gbps • Transmission Method • Adopt Store-and-forward. • Data Transfer Rates Gigabit Ethernet 1000 Mbps, Ethernet 100 Mbps • Packet Filtering / Forwarding Rates "10M port maximum 14800pps. • 100M port maximum 148800pps • 1000M port maximum 1488000pps" • PoE Standards IEEE 802.3af, IEEE 802.3at • PoE-Capable Ports Port 1 - 24 (Port 1 - 8 PoE can support up to 250m @ 10Mbps with Extend enabled) • Power Budget 250W (30 W max. per PoE port) • Temperature Operating: 0 to 40 ˚C (32 to 104 ˚F) • Certification EMI/EMC, CE
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 16 PORT FAST ETHERNET UNMANAGED POE SWITCH • 16 10/100/1000 BASE-T ports • 2 SFP" • IEEE 802.3u,FastEthernet standard • IEEE 802.3af/at ,Ethernet power supply POE• IEEE 802.3ab,Gigabit Ethernet standards • IEEE 802.3az ,EEE, Energy efficient Ethernet• IEEE 802.3x, Full-duplex Ethernet data link layers • IEEE 802.3z ,Gigabit Ethernet fiber-optic • Media Interface Exchange • Auto MDI/MDI-X adjustment on all ports • Lighting Protection • 6KV • Switching Fabric • 36 Gbps • Transmission Method Adopt Store-and-forward • Data Transfer Rates Gigabit Ethernet 1000 Mbps Ethernet 100Mbps • Packet Filtering / Forwarding Rates 10M port maximum 14800pps, 100M port maximum , 148800pps 1000M port, maximum 1488000pps • PoE Standards IEEE 802.3af, IEEE 802.3at • PoE-Capable PortsPort 1 - 16 (Port 1 - 8 PoE can support up to 250m @ 10Mbps with Extend enabled) • Power Budget 150W (30 W max. per PoE port)
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF NETWORK VIDEO RECORDER (64-CH) NVR • IP video input 64-ch • Incoming bandwidth NVR Shall Support 300 Mbps or better • Outgoing bandwidth NVR Shall Support 240 Mbps or better • Recording resolution NVR Shall Support up to 12 MP resolution or higher • HDMI output resolution NVR Shall Support 4K (3840 × 2160) • Synchronous playback NVR Shall Support 16-ch playback • Analytics Face picture comparison (4-ch face picture comparison alarm), human face capture • (1-ch human face capture ), face picture search • Face picture library Up to 16 face picture libraries, with up to 10,000 face pictures in total • Network protocols TCP/IP, DHCP, DNS, DDNS, NTP, SMTP, NFS, iSCSI, UPnP™, HTTPS • SATA NVR Shall Support 8 SATA interface • Capacity NVR Shall Support up to 10 TB capacity for each HDD • eSATA 1 eSATA interface • Network interface 2, RJ-45 10/100/1000 Mbps self-adaptive Ethernet interface • USB interface 2 × USB 2.0, 1 × USB 3.0 • Two-way audio NVR Shall Support1-ch, RCA • Alarm in/out 16/8 • Working temperature 0 °C to 50 °C • Certifications CE, FCC, BIS
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF BULLET CAMERA 5 MP 40 METER IR • Parameters Value • Image Sensor 1/2.7″ Progressive Scan CMOS • Min. Illumination Color: 0.01 Lux @(F1.2; AGC ON) • Max. Resolution 2560 × 1920 or better • WDR WDR should be 120dB or higher • Focal length 4 mm/6mm • IR Range Camera Shall Support Up to 40 m IR or better • Behavior Analysis Line crossing detection, intrusion detection • Region of Interest Camera Shall Support 1 region • Image Enhancement BLC, HLC, 3D DNR • Protocols TCP/IP, ICMP, HTTP, HTTPS, FTP, DHCP, DNS, DDNS, RTP, RTSP, NTP, IPv4, IPv6 • Simultaneous Live View Up to 6 channels • User Up to 32 users • Communication Interface 1 RJ45 10M/100M • Operating Conditions -30 °C to 60 °C • Protection Level IP67 • Certifications CE, FCC, BIS"
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF DOME CAMERA 5 MP 40 METER IR • Parameters Value • Image Sensor 1/2.7"" Progressive Scan CMOS • Min. Illumination Color: 0.005 Lux @ (F1.6, AGC ON) • Max. Resolution 2560 × 1920 @20fps or better • WDR WDR should be 120dB or higher • Focal length 2.8 mm/4mm • IR Range Camera Shall Support Up to 40 m IR range • Behavior Analysis Line crossing detection, intrusion detection • Region of Interest Camera Shall Support 1 region • Image Enhancement BLC, HLC, 3D DNR • Protocols TCP/IP, ICMP, HTTP, HTTPS, FTP, DHCP, DNS, DDNS, RTP, RTSP, RTCP, NTP, SSL/TLS • Simultaneous Live View Up to 6 channels • User Up to 32 users • Communication Interface 1 RJ45 10 M/100 M • On-Board Storage Camera Shall Support up to 256 GB or more • Alarm Camera Shall Support 1 input, 1 output alarm • Operating Conditions -30 °C to 60 °C • Protection Level Camera Shall Support IP67, IK10 • Certifications CE, FCC, BIS
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF Surveillance Hard Disk Storage Device (4 TB) • Surveillance Storage drive,Specially designed AV storage device with unique surveillance feature
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 36U Closed Rack / Width 800 / Depth 1000 • Adjustable 19” equipment mounting verticals provide the better mounting flexibility maximizing the usable mounting space • Precision engineering capabilities and best efficient software configuration product technology provides the best product quality and fastest delivery in the industry • Top and bottom Panel with ventilation and cable entry facility • Powder coated finish with pretreatment process meeting all industry standards • 100% assured compatibility with all equipment conforming to DIN 41494. General industrial standard for equipment • Castor wheels Set of 4 (Front 2 wheels with Break and rear without break) with Levelers • Adjustable Levelers set of 4 • 19" Reduced Channel - Loop Type • Lockable Toughened Glass Door-800-36U • Rear Metal Door-800-36U-Vented Dual • Side Panels-1000-36U-Vented (Set of 2) • Mounting Hardware-(Pack of 20) • Provision to mount the cooling fans on the top panel FHU with 2 FAN 180CFM • Vertical Power Distribution Unit with 12 x 5/15 sockets Round Pin, 230 Volts AC, 32 Amp with Plug • Horz. Cable Manager-1U-Loop • Static Load : 500+ kgs, UL Certified.
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF INDOOR 12U x 550 W x 450 D • Conforms to DIN 41494 OR equivalent ISO Standards • Front Glass Door (tinted, Toughened) with Lock & Key, • 2 pairs of 19" Mounting Rails with U-Marking • Welded to Frame Top and Bottom Cover, Vented and Field Cable entry exit cut outs • UL Certified. • Standard Accessories: • 1U Cable Manager (1), • Hardware Pkt of 20 (1 Pkt) • 6 Socket 5 Amp. Power Distribution Unit (1 No) • Roof Mounted Fan Unit / 90 CFM /230V AC (1 No) • Standard Color : Grey/White/Black, Static Load : 40 kgs
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF OUTDOOR 9U RACK • Conforms to DIN 41494 OR equivalent ISO Standards • Front Door with Lock & Key, • 2 pairs of 19" Mounting Rails with U-Marking • UL Certified. • Standard Accessories: • 1U Cable Manager (1), • Hardware Pkt of 20 (1 Pkt) • 6 Socket 5 Amp. Power Distribution Unit (1 No) • Door Mounted Fan Unit / 90 CFM /230V AC (2 No) • Standard Color : Grey/White/Black, Static Load : 40 kgs
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF UTP CAT6 I/O BOX COMPLETE SITC (KEYSTONE JACK, UTP CAT6 FACE PLATE &SMB) • UTP CAT6 KEYSTONE JACK: · Category 6, TIA568 C.2 · All information outlets for 100 W, 22-26 AWG copper cable shall: · Use insulation displacement connectors (IDC) · Allow for a minimum of 200 re-terminations without signal degradation below standards compliance limits. · Be constructed of high impact, flame-retardant thermoplastic with color and icon options for better visual identification. · Shutter is on face plate · Insertion force: 20N max ( IEC 60603-7-4 ) · IDC : Housing PC + glass fiber , UL 94 V-2 · 568A/B configuration · Operation Temp: -10 C to 60 C · Plastic Housing: Polycarbonate, UL94V-0 rated or equivalent · Operating Life: Minimum 750 insertion cycles · Contact Material: Copper alloy · Contact Plating: 50 µinches gold on plug contact area · Plastic Housing: Polycarbonate + glass fiber UL94V-2 rated · Operating Life: Minimum 200 Re-terminations · IDC Contact Plating: Phosphor bronze with tin plated • UTP CAT6 FACE PLATE: · Single square plate, Quad in Rectangular shape · Write on labels in transparent plastic window – supplied with plate · Screw hole covers – to be supplied with plate · Face Plate with shutter · Should be able to support variety of jacks – UTP, STP • PVC SMB BACK BOX
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF UTP CAT6 LOADED PATCH PANNEL • Allow for a minimum of 200 re-terminations without signal degradation below standards compliance limit. • made of powder coated steel, in 24 port configurations. • Have port identification numbers on the front of the panel. • Should have self-adhesive, clear label holders (transparent plastic window type) and white designation labels with the panel, with optional color labels / icons. • IDC: Suitable for 22-26 AWG stranded and solid wire compatible with both 110 & Krone punch down tools • Each port / jack on the panel should be individually removable on field from the panel. • Improved cable management with optional cable management bar • The Cat-6 transmission performance is in compliance with the ANSI/TIA/EIA 568C.2 standard • Plastic Housing: ABS , UL94V-0 rated , Operating Life: Minimum 750 insertion cycles, Contact Material: Copper Alloy • Contact Plating: 50µ” Gold plated on plug contact area • Contact Force: 20N max ( IEC 60603-7-4) • Plug Retention Force: 15 lb. • Plastic Housing: Polycarbonate, UL94V-0 rated or equivalent • IDC cap : ABS, UL 94V -0 • Contact Material: Copper Alloy • IDC Contact Plating: Phosphor bronze with tin plated • Insertion Force: 20N max ( IEC 60603-7-4 ) • Wire Accommodation: 22-26 AWG solid
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 1 MTR UTP CAT6 PATCH CARD • Features Category 6 Equipment cords • The work area equipment cords shall, at a minimum comply with proposed ANSI/TIA/EIA-568-C.2 Commercial Building Cabling Standards Transmission Performance Specifications for 4 pair 100W Category 6 Cabling. • Equipped with modular 8-position modular plugs on both ends, wired straight through with standards compliant wiring. • Should have 50 micrinches of gold plating over nickel contacts. • Should be covered by ETL verification program for compliance with TIA 568.C.2 • Mechanical : Cable Conductor size: 24 AWG stranded bare copper • Max O.D.: 5.6mm (.22”) • Jacket: PVC UL-94V-O • Temperature range: -10oC t+80oC • Mechanical Characteristics – Plug Operating life: Minimum 750 insertion cycles • Contact blade: Phosphor bronze • Contact plating: 50µ” Gold • Plug dimensions & tolerances compliant with FCC Part 68.500 and IEC 60603-7 • Approvals: UL 444 for copper conductor • Operating life: Minimum 750 insertion cycles • Electrical Characteristics – Plug Diélectrique with standing voltage :500 V AC • Insolation résistance : 35 M Ohm (Max) • Operating temperature: -10oC t80oC
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 3 MTR UTP CAT6 PATCH CARD • Features Category 6 Equipment cords • The work area equipment cords shall, at a minimum comply with proposed ANSI/TIA/EIA-568-C.2 Commercial Building Cabling Standards Transmission Performance Specifications for 4 pair 100W Category 6 Cabling. • Equipped with modular 8-position modular plugs on both ends, wired straight through with standards compliant wiring. • Should have 50 micrinches of gold plating over nickel contacts. • Should be covered by ETL verification program for compliance with TIA 568.C.2 • Mechanical : Cable Conductor size: 24 AWG stranded bare copper • Max O.D.: 5.6mm (.22”) • Jacket: PVC UL-94V-O • Temperature range: -10oC t+80oC • Mechanical Characteristics – Plug Operating life: Minimum 750 insertion cycles • Contact blade: Phosphor bronze • Contact plating: 50µ” Gold • Plug dimensions & tolerances compliant with FCC Part 68.500 and IEC 60603-7 • Approvals: UL 444 for copper conductor • Operating life: Minimum 750 insertion cycles • Electrical Characteristics – Plug Diélectrique with standing voltage :500 V AC • Insolation résistance : 35 M Ohm (Max) • Operating temperature: -10oC t80oC
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF CAT6 UTP Cable Indoor Type • Category 6 Unshielded Twisted Pair 4 pair 100W cable shall be compliant • with ANSI/TIA/EIA-568-C.2 Additional Transmission Performance Specifications for 4-pair 100W Category 6Cabling. • Category 6 UTP cables shall extend between the work area location and its associated telecommunications closet and consist of 4 pair, 23 AWG, UTP. • The 4 pair Unshielded Twisted Pair cable shall be UL/ETL • Construction: 4 twisted pairs separated by internal X shaped, 4 channel, polymer spine / full separator. Half shall not be accepted. • Conductor Solid bare Copper • Conductor Diameter 0.56±0.005mm (23 AWG) • Insulation :High Density Polyethylene • Jacket Color : RED • Jacket FR PVC / LSZH • Outer Diameter 6.1 mm nominal • Temperature Range -20° to +70°C
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 12 PORT LOADED RACK MOUNT LIU WITH PIGTAIL AND SPLICING • Should be Rack Mount for 6 Port and should be loaded. • Front-mounted cable saddles for jumper management • Can manage both splices and terminations • Preassembled shelves in multiple configurations • Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers • 2 fiber spools built-in for 900μm tight buffered fiber storing • Capable of storing up to 3 meters of 900μm tight buffered fiber per adapter • Removable front and rear covers for better access to interior of LIU • Should be Single mode LC Type fully loaded. • Accessory kit consists of cable ties, mounting ear screws, and spiral wrap tube
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 6 CORE ARMORED FIBER CABLE • The Fiber should be 6 core Fiber. • The Fiber should follow Standards: ISO 11801, IEC 60793-1/60794-1-2/60794-3-10 and ITU-T-REC G.652D. • The Fiber should be with High quality Electro Chromium Coated Corrugated Steel tape (ECCS) and LSZH- Sheath • The Fiber Operating Temperature should be – 20 deg C to +60 deg C and Storage Temperature should be – 20 deg C to +60 deg C" • The Fiber Max Attenuation ± 0.36 (db / km) @ Operational Wavelength 1310 nm and, ± 0.22 (db / km) @ Operational Wavelength 1550 nm. • The Fiber - type should be 9/125 / G.652D & Refractive Index should be 1.4674/1.4679 • The value for Mode-filed/Cladding Diameter (um) 9.2 ± 0.4 and 125 ± 0.7 • The Dispersion value <=3.5 <=18 (ps/(nm-km) and PMD value <=0.2 (ps/km) and Cable Cut-off wavelength <=1260 (nm)
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF OPTICAL FIBER PATCH CORD SM SC TO LC DUPLEX PATCH CORD • Adopts high precision ceramic ferrule with good concentricity • Fiber corning single mode G652D,G657A,G657B • Cable Type 0.9mm • Mechanical specification Apex Offset :-< 50 um • Mechanical specification Fiber Height +(-) 100 nm • End-face radius of Curvature 7mm < R <25mm • Repeatability <(-) 0.2 db • Working Temperature :- -4 0 c ~ +65 o C • Storage Temperature:- 40 o C ~ + 65 o C • Length -- 2Mtr • Type -- SC-LC Duplex
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF PLB DUCT FOR FIBER 40MM PER MTR (ISI)
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF PVC CONDUIT 25MM FRL GRADE/PIPES, SADDLES, FASTNERS, HANGERS, STEEL TRAYS SCREWS ETC OF STANDARD GRADE (ISI)
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 65" Display • Resolution:-. Ultra HD 3840 x 2160 • Display Type:-. 4K UHD • Picture Processor :- α5 Gen5 AI Processor :- 4K or higher • Refresh Rate:- 60Hz • HDR:- Active HDR • HDR 10 Pro :- Yes • HLG:- Yes • AI Brightness:- Yes • AI Functions :- AI Home, AI Recommendation, Intelligent Edit • Speaker System:-. 2.0 Ch SpeakerAudio Output (rms):-. 20W • Speaker Direction:- Down Firing • AI Sound Pro/ AI Sound :- AI Sound (Virtual 5.1 Up-mix) • Wi-Fi (Built-in) :- Wi-Fi 5 (802.11ac) • Bluetooth:- Yes (V 5.0) • Simplink (HDMI CEC):- Yes • HDMI Input:- 1 (Rear) / 2 (Side) • USB Ports :- 1 (Side) • HDMI Audio Return Channel:- eARC (HDMI 2)RF Input 1 (Rear) • LAN:- 1 (Rear) • Digital Audio Out :- (Optical) 1 (Rear)
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 1G SFP Transceiver for Single Mode Fiber • Transceiver should be Small Form-Pluggable (SFP) form factor and compatible with quoted switches. • Transceiver should be Hot pluggable and support 1G speed on Single Mode, Multi-Source Agreement (MSA) Compliant and RoHS Compliant • Transceiver should be compliant with IEEE802.3z standards. • Transceiver distance capacity should be 10Km. • Transceiver interface should be Duplex LC connector. • Transceiver should support Single-mode 9 um fiber. • Certification - FCC, CE, VCCI
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF OUTDOOR 4 SQ MM WIRE 2 CORE SHEILDED • Category: Multicore Flexible Cables • Color: Black • Conductor: Copper • Core: 2 • Sq. mm: 4 • Type: PVC • Voltage: 1.1 KV
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 2.5MM WIRE SINGLE CORE
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 10 kVA UPS • TYPE: True Online , DSP Controlled online UPS with 1 phase AC input and 1 phase AC output with 12V SMF batteries (65 AH) Bank with Rack ,The UPS should be with IGBT Based Rectifier and Inverter and with LCD/LED display for monitoring of its status along with inbuilt Galvanic Isolation Transformer of Same OEM Make at input side. • FEATURE: Input PF should be 0.99 and output PF not less than 0.8 , Efficiency: eco mode efficiency (up to 97%),Communication interface : RS232/USB port Audible Alarm : Mains Failure/Low battery /UPS Warning /Overload/Fault & Bypass Mode, Built in Automatic & Maintenance Bypass Switch.
PART B PART A ( Technical Specifications as Annexure E)
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF LAYER 2 NON-POE GIGABIT SMART MANAGED SWITCH • Switch with at least 24 X 10/100/1000 Mbps Ports and COMBO Ports (10/100/1000 or 100/1000 SFP • Switch Should Support Link status detection, Port and LED shut-off, System hibernation. • Switching capacity should be 50 Gbps or higher or non-blocking architecture. • Switch packet forwarding rate should be 40 Mpps or higher or non-blocking architecture. • Switch MAC table should be at least 6K or higher. • Power input should be 100 to 240 VAC, 50/60 Hz, internal power supply. Power Saving (Green) • Operating temperature should be -5 degree Celsius to +50 degree Celsius. • EMI Certificate - CE, FCC/IEC and SAFETY Certificate - CB/ UL. • Switch Software Specification • Should support Head of Line blocking prevention for lower latency and better performance. • Support Jumbo Frame up to 6K Bytes or higher. • Link Aggregation LACP 802.3ad: Minimum 8 groups per device and 8 ports per group • Port Mirroring: One-to-One / Many-to-One • Switch Should Support Access Control List based on (ACL's) 802.1p priority, VLAN, MAC address, Ether type, IP address, DSCP, Protocol type, TCP/UDP port number, IPv6 Traffic Class, Max. ACL Profiles • Should have 802.1D STP, 802.1w RSTP and 802.1s MSTP Spanning Tree Protocol. • Should support Spanning tree Root restriction. • Should support Loopback detection (LBD) to detect the loop created by a specific port. • Should support Multicast Filtering to filters or forward all unregistered groups. • Switch should support IEEE 802.1Q VLAN tagging for Ethernet frames. • Different type of VLAN like Port based, Auto Surveillance, Auto Voice, Asymmetric Vlan etc. should be available for configuration. • Switch should support QoS (quality of service) IEEE 802.1P for traffic prioritization. It should support 4 queues per port. • Different type of QoS priority like Strict Priority Queue and Weighted Round Robin. • Port based ingress / egress rate limit function should be available with limit in increments as low as 8 Kbps • Switch should support Neighbour Discovery (ND) protocol for IPv6. • Switch should support to create at least 4 IP interface. • Support at least 100 rules shared by IPv4, MAC, and IPv6 & Each rule can only be associated with a single port. • Should support port security to secures the access port based on MAC address. • should have broadcast, multicast, and unicast storm control to prevents faulty end stations from degrading overall systems performance. • Support Traffic Segmentation to restricted traffic flow from a single or group of ports, to another group of ports. • Should have SSH and SSL for IPv4 and IPv6. • Require prevention of DoS attacks, which include Land, TCP Null Scan, TCP Xmas Scan and TCP SYNFIN. • Should support 802.1X port-based authentication. • Should support ARP spoofing prevention. • Should support DHCP snooping and DHCP server screening. • Switch should be able to create a binding table for IP + MAC + Port to prevents a malicious user from spoofing or to restrict the unauthorized users. • Should support 802.1X RADIUS and local server database authentication. • Should have option to check the status of copper cables using the cable-diagnostics time domain reflectometer (TDR). • Able to manage trough Web-GUI, CLI, Telnet & SNMP • Should support SNMP v1, v2c, v3 and SNMP Traps and Remote Monitoring (RMON). • Should have dual Image support to reduced down time for the switches. • Should have SNTP/NTP protocol for time synchronization. • Should support Link Layer Discovery Protocol (LLDP) and LLDP-MED. • Switches and Fiber Modules should be from Same OEM • Switch should be supplied with the all-necessary components like Power cord, Rack-mount bracket, Installation Guide, etc. and necessary software image file to fulfil all above-mentioned feature set from day 1.
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 16 PORT FAST ETHERNET UNMANAGED POE SWITCH • 16 10/100/1000 BASE-T ports • 2 SFP" • IEEE 802.3u,FastEthernet standard • IEEE 802.3af/at ,Ethernet power supply POE• IEEE 802.3ab,Gigabit Ethernet standards • IEEE 802.3az ,EEE, Energy efficient Ethernet• IEEE 802.3x, Full-duplex Ethernet data link layers • IEEE 802.3z ,Gigabit Ethernet fiber-optic • Media Interface Exchange • Auto MDI/MDI-X adjustment on all ports • Lighting Protection • 6KV • Switching Fabric • 36 Gbps • Transmission Method Adopt Store-and-forward • Data Transfer Rates Gigabit Ethernet 1000 Mbps Ethernet 100Mbps • Packet Filtering / Forwarding Rates 10M port maximum 14800pps, 100M port maximum , 148800pps 1000M port, maximum 1488000pps • PoE Standards IEEE 802.3af, IEEE 802.3at • PoE-Capable PortsPort 1 - 16 (Port 1 - 8 PoE can support up to 250m @ 10Mbps with Extend enabled) • Power Budget 150W (30 W max. per PoE port)
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF NETWORK VIDEO RECORDER (64-CH) NVR • IP video input 64-ch • Incoming bandwidth NVR Shall Support 300 Mbps or better • Outgoing bandwidth NVR Shall Support 240 Mbps or better • Recording resolution NVR Shall Support up to 12 MP resolution or higher • HDMI output resolution NVR Shall Support 4K (3840 × 2160) • Synchronous playback NVR Shall Support 16-ch playback • Analytics Face picture comparison (4-ch face picture comparison alarm), human face capture • (1-ch human face capture ), face picture search • Face picture library Up to 16 face picture libraries, with up to 10,000 face pictures in total • Network protocols TCP/IP, DHCP, DNS, DDNS, NTP, SMTP, NFS, iSCSI, UPnP™, HTTPS • SATA NVR Shall Support 8 SATA interface • Capacity NVR Shall Support up to 10 TB capacity for each HDD • eSATA 1 eSATA interface • Network interface 2, RJ-45 10/100/1000 Mbps self-adaptive Ethernet interface • USB interface 2 × USB 2.0, 1 × USB 3.0 • Two-way audio NVR Shall Support1-ch, RCA • Alarm in/out 16/8 • Working temperature 0 °C to 50 °C • Certifications CE, FCC, BIS
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF BULLET CAMERA 5 MP 40 METER IR • Parameters Value • Image Sensor 1/2.7″ Progressive Scan CMOS • Min. Illumination Color: 0.01 Lux @(F1.2; AGC ON) • Max. Resolution 2560 × 1920 or better • WDR WDR should be 120dB or higher • Focal length 4 mm/6mm • IR Range Camera Shall Support Up to 40 m IR or better • Behavior Analysis Line crossing detection, intrusion detection • Region of Interest Camera Shall Support 1 region • Image Enhancement BLC, HLC, 3D DNR • Protocols TCP/IP, ICMP, HTTP, HTTPS, FTP, DHCP, DNS, DDNS, RTP, RTSP, NTP, IPv4, IPv6 • Simultaneous Live View Up to 6 channels • User Up to 32 users • Communication Interface 1 RJ45 10M/100M • Operating Conditions -30 °C to 60 °C • Protection Level IP67 • Certifications CE, FCC, BIS"
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF DOME CAMERA 5 MP 40 METER IR • Parameters Value • Image Sensor 1/2.7"" Progressive Scan CMOS • Min. Illumination Color: 0.005 Lux @ (F1.6, AGC ON) • Max. Resolution 2560 × 1920 @20fps or better • WDR WDR should be 120dB or higher • Focal length 2.8 mm/4mm • IR Range Camera Shall Support Up to 40 m IR range • Behavior Analysis Line crossing detection, intrusion detection • Region of Interest Camera Shall Support 1 region • Image Enhancement BLC, HLC, 3D DNR • Protocols TCP/IP, ICMP, HTTP, HTTPS, FTP, DHCP, DNS, DDNS, RTP, RTSP, RTCP, NTP, SSL/TLS • Simultaneous Live View Up to 6 channels • User Up to 32 users • Communication Interface 1 RJ45 10 M/100 M • On-Board Storage Camera Shall Support up to 256 GB or more • Alarm Camera Shall Support 1 input, 1 output alarm • Operating Conditions -30 °C to 60 °C • Protection Level Camera Shall Support IP67, IK10 • Certifications CE, FCC, BIS
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF Surveillance Hard Disk Storage Device (4 TB) • Surveillance Storage drive,Specially designed AV storage device with unique surveillance feature
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF INDOOR 12U x 550 W x 450 D • Conforms to DIN 41494 OR equivalent ISO Standards • Front Glass Door (tinted, Toughened) with Lock & Key, • 2 pairs of 19" Mounting Rails with U-Marking • Welded to Frame Top and Bottom Cover, Vented and Field Cable entry exit cut outs • UL Certified. • Standard Accessories: • 1U Cable Manager (1), • Hardware Pkt of 20 (1 Pkt) • 6 Socket 5 Amp. Power Distribution Unit (1 No) • Roof Mounted Fan Unit / 90 CFM /230V AC (1 No) • Standard Color : Grey/White/Black, Static Load : 40 kgs
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF UTP CAT6 I/O BOX COMPLETE SITC (KEYSTONE JACK, UTP CAT6 FACE PLATE &SMB) • UTP CAT6 KEYSTONE JACK: · Category 6, TIA568 C.2 · All information outlets for 100 W, 22-26 AWG copper cable shall: · Use insulation displacement connectors (IDC) · Allow for a minimum of 200 re-terminations without signal degradation below standards compliance limits. · Be constructed of high impact, flame-retardant thermoplastic with color and icon options for better visual identification. · Shutter is on face plate · Insertion force: 20N max ( IEC 60603-7-4 ) · IDC : Housing PC + glass fiber , UL 94 V-2 · 568A/B configuration · Operation Temp: -10 C to 60 C · Plastic Housing: Polycarbonate, UL94V-0 rated or equivalent · Operating Life: Minimum 750 insertion cycles · Contact Material: Copper alloy · Contact Plating: 50 µinches gold on plug contact area · Plastic Housing: Polycarbonate + glass fiber UL94V-2 rated · Operating Life: Minimum 200 Re-terminations · IDC Contact Plating: Phosphor bronze with tin plated • UTP CAT6 FACE PLATE: · Single square plate, Quad in Rectangular shape · Write on labels in transparent plastic window – supplied with plate · Screw hole covers – to be supplied with plate · Face Plate with shutter · Should be able to support variety of jacks – UTP, STP • PVC SMB BACK BOX
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF UTP CAT6 LOADED PATCH PANNEL • Allow for a minimum of 200 re-terminations without signal degradation below standards compliance limit. • made of powder coated steel, in 24 port configurations. • Have port identification numbers on the front of the panel. • Should have self-adhesive, clear label holders (transparent plastic window type) and white designation labels with the panel, with optional color labels / icons. • IDC: Suitable for 22-26 AWG stranded and solid wire compatible with both 110 & Krone punch down tools • Each port / jack on the panel should be individually removable on field from the panel. • Improved cable management with optional cable management bar • The Cat-6 transmission performance is in compliance with the ANSI/TIA/EIA 568C.2 standard • Plastic Housing: ABS , UL94V-0 rated , Operating Life: Minimum 750 insertion cycles, Contact Material: Copper Alloy • Contact Plating: 50µ” Gold plated on plug contact area • Contact Force: 20N max ( IEC 60603-7-4) • Plug Retention Force: 15 lb. • Plastic Housing: Polycarbonate, UL94V-0 rated or equivalent • IDC cap : ABS, UL 94V -0 • Contact Material: Copper Alloy • IDC Contact Plating: Phosphor bronze with tin plated • Insertion Force: 20N max ( IEC 60603-7-4 ) • Wire Accommodation: 22-26 AWG solid
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 1 MTR UTP CAT6 PATCH CARD • Features Category 6 Equipment cords • The work area equipment cords shall, at a minimum comply with proposed ANSI/TIA/EIA-568-C.2 Commercial Building Cabling Standards Transmission Performance Specifications for 4 pair 100W Category 6 Cabling. • Equipped with modular 8-position modular plugs on both ends, wired straight through with standards compliant wiring. • Should have 50 micrinches of gold plating over nickel contacts. • Should be covered by ETL verification program for compliance with TIA 568.C.2 • Mechanical : Cable Conductor size: 24 AWG stranded bare copper • Max O.D.: 5.6mm (.22”) • Jacket: PVC UL-94V-O • Temperature range: -10oC t+80oC • Mechanical Characteristics – Plug Operating life: Minimum 750 insertion cycles • Contact blade: Phosphor bronze • Contact plating: 50µ” Gold • Plug dimensions & tolerances compliant with FCC Part 68.500 and IEC 60603-7 • Approvals: UL 444 for copper conductor • Operating life: Minimum 750 insertion cycles • Electrical Characteristics – Plug Diélectrique with standing voltage :500 V AC • Insolation résistance : 35 M Ohm (Max) • Operating temperature: -10oC t80oC
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 3 MTR UTP CAT6 PATCH CARD • Features Category 6 Equipment cords • The work area equipment cords shall, at a minimum comply with proposed ANSI/TIA/EIA-568-C.2 Commercial Building Cabling Standards Transmission Performance Specifications for 4 pair 100W Category 6 Cabling. • Equipped with modular 8-position modular plugs on both ends, wired straight through with standards compliant wiring. • Should have 50 micrinches of gold plating over nickel contacts. • Should be covered by ETL verification program for compliance with TIA 568.C.2 • Mechanical : Cable Conductor size: 24 AWG stranded bare copper • Max O.D.: 5.6mm (.22”) • Jacket: PVC UL-94V-O • Temperature range: -10oC t+80oC • Mechanical Characteristics – Plug Operating life: Minimum 750 insertion cycles • Contact blade: Phosphor bronze • Contact plating: 50µ” Gold • Plug dimensions & tolerances compliant with FCC Part 68.500 and IEC 60603-7 • Approvals: UL 444 for copper conductor • Operating life: Minimum 750 insertion cycles • Electrical Characteristics – Plug Diélectrique with standing voltage :500 V AC • Insolation résistance : 35 M Ohm (Max) • Operating temperature: -10oC t80oC
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF CAT6 UTP Cable Indoor Type • Category 6 Unshielded Twisted Pair 4 pair 100W cable shall be compliant • with ANSI/TIA/EIA-568-C.2 Additional Transmission Performance Specifications for 4-pair 100W Category 6Cabling. • Category 6 UTP cables shall extend between the work area location and its associated telecommunications closet and consist of 4 pair, 23 AWG, UTP. • The 4 pair Unshielded Twisted Pair cable shall be UL/ETL • Construction: 4 twisted pairs separated by internal X shaped, 4 channel, polymer spine / full separator. Half shall not be accepted. • Conductor Solid bare Copper • Conductor Diameter 0.56±0.005mm (23 AWG) • Insulation :High Density Polyethylene • Jacket Color : RED • Jacket FR PVC / LSZH • Outer Diameter 6.1 mm nominal • Temperature Range -20° to +70°C
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 12 PORT LOADED RACK MOUNT LIU WITH PIGTAIL AND SPLICING • Should be Rack Mount for 6 Port and should be loaded. • Front-mounted cable saddles for jumper management • Can manage both splices and terminations • Preassembled shelves in multiple configurations • Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers • 2 fiber spools built-in for 900μm tight buffered fiber storing • Capable of storing up to 3 meters of 900μm tight buffered fiber per adapter • Removable front and rear covers for better access to interior of LIU • Should be Single mode LC Type fully loaded. • Accessory kit consists of cable ties, mounting ear screws, and spiral wrap tube
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 6 CORE ARMORED FIBER CABLE • The Fiber should be 6 core Fiber. • The Fiber should follow Standards: ISO 11801, IEC 60793-1/60794-1-2/60794-3-10 and ITU-T-REC G.652D. • The Fiber should be with High quality Electro Chromium Coated Corrugated Steel tape (ECCS) and LSZH- Sheath • The Fiber Operating Temperature should be – 20 deg C to +60 deg C and Storage Temperature should be – 20 deg C to +60 deg C" • The Fiber Max Attenuation ± 0.36 (db / km) @ Operational Wavelength 1310 nm and, ± 0.22 (db / km) @ Operational Wavelength 1550 nm. • The Fiber - type should be 9/125 / G.652D & Refractive Index should be 1.4674/1.4679 • The value for Mode-filed/Cladding Diameter (um) 9.2 ± 0.4 and 125 ± 0.7 • The Dispersion value <=3.5 <=18 (ps/(nm-km) and PMD value <=0.2 (ps/km) and Cable Cut-off wavelength <=1260 (nm)
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF OPTICAL FIBER PATCH CORD SM SC TO LC DUPLEX PATCH CORD • Adopts high precision ceramic ferrule with good concentricity • Fiber corning single mode G652D,G657A,G657B • Cable Type 0.9mm • Mechanical specification Apex Offset :-< 50 um • Mechanical specification Fiber Height +(-) 100 nm • End-face radius of Curvature 7mm < R <25mm • Repeatability <(-) 0.2 db • Working Temperature :- -4 0 c ~ +65 o C • Storage Temperature:- 40 o C ~ + 65 o C • Length -- 2Mtr • Type -- SC-LC Duplex
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF PLB DUCT FOR FIBER 40MM PER MTR (ISI)
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF OF PVC CONDUIT 25MM FRL GRADE/PIPES, SADDLES, FASTNERS, HANGERS, STEEL TRAYS SCREWS ETC OF STANDARD GRADE (ISI)
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 65" Display • Resolution:-. Ultra HD 3840 x 2160 • Display Type:-. 4K UHD • Picture Processor :- α5 Gen5 AI Processor :- 4K or higher • Refresh Rate:- 60Hz • HDR:- Active HDR • HDR 10 Pro :- Yes • HLG:- Yes • AI Brightness:- Yes • AI Functions :- AI Home, AI Recommendation, Intelligent Edit • Speaker System:-. 2.0 Ch SpeakerAudio Output (rms):-. 20W • Speaker Direction:- Down Firing • AI Sound Pro/ AI Sound :- AI Sound (Virtual 5.1 Up-mix) • Wi-Fi (Built-in) :- Wi-Fi 5 (802.11ac) • Bluetooth:- Yes (V 5.0) • Simplink (HDMI CEC):- Yes • HDMI Input:- 1 (Rear) / 2 (Side) • USB Ports :- 1 (Side) • HDMI Audio Return Channel:- eARC (HDMI 2)RF Input 1 (Rear) • LAN:- 1 (Rear) • Digital Audio Out :- (Optical) 1 (Rear)
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 1G SFP Transceiver for Single Mode Fiber • Transceiver should be Small Form-Pluggable (SFP) form factor and compatible with quoted switches. • Transceiver should be Hot pluggable and support 1G speed on Single Mode, Multi-Source Agreement (MSA) Compliant and RoHS Compliant • Transceiver should be compliant with IEEE802.3z standards. • Transceiver distance capacity should be 10Km. • Transceiver interface should be Duplex LC connector. • Transceiver should support Single-mode 9 um fiber. • Certification - FCC, CE, VCCI
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF OUTDOOR 4 SQ MM WIRE 2 CORE SHEILDED • Category: Multicore Flexible Cables • Color: Black • Conductor: Copper • Core: 2 • Sq. mm: 4 • Type: PVC • Voltage: 1.1 KV
Insat Techno Services
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.70 MB
Tendernotice_2.pdf
PDF • 0.99 MB
BOQ_688509.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .