Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l-1₹13.4 LAccepted-AOC 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | l-1 | Accepted-AOC Tender accepted due to lowest and quoted reasonable rates | |
| 2 | l-2₹20.1 L+₹6.7 L (50.1%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | l-2 | Rejected-Finance Higher side quoted amount |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
7 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Khumbathang
CWE Khumbathang
REPAIR MAINT OF ALL WEATHER WATER SUPPLY NETWORK AT VARIOUS LOCATION UNDER GE KHUMBATHANG
2022_MES_553046_2
80051/79/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
khumbathang
As per tender and NIT doc
8 documents required · 8 mandatory
₹500
GE Khumbathang
₹30,000
19 Dec 2022
19 Oct 2022
8 Nov 2022
19 Oct 2022
7 Nov 2022
26 Oct 2022
Amount
M&L for cleaning the steel under ground water storage tank (inside surfaces only) of capacity 5000 Ltrs by scraping, scrubbing (without damaging the tank surfaces) with coir brushes and removing all deposits/scales, algae formations, silt/other sticky or foreign materials from adhering tank surfaces and washing inside surfaces of tank with approved bleaching powder solution and finally recleaning with fresh plain water to remove any trace of bleaching powder all as specified and directed by Engr in charge. Note: Item rate includes necessary disconnection and reconnection of pipelines before and after cleaning of the tank where required.
M&L for lifting of submersible pump motor set of any description and capacity including dismantling MS column pipe, steel wire rope from the bore well upto a depth of 90 mtr complete all as specified and directed.
Re-installations of pump and motor set in the bore well in the same position alongwith all necessary work like fixing of column pipe, connections of rope with U clamps, connection to the discharge line, dry revolution test etc complete all as specified and directed.
Dismantling the submersible motor of any make for assessing the extent of repair for inspection of Engr-in-Charge and transporation of motor from site to the work shop for repair/rewinding (rewinding and spares will be measured separately under relevant item as supply only) including repalcement of unserviceable minor parts like nuts, bolts, washers, gaskets, rubber ring etc, return back the motor from workshop to site after complete repair duly painted with one coat of synthetic enamel paint after preparation of surfaces for Motor capacity up to 10 HP complete all as specified and directed. Note: Item rate includes transportation of motor from site to workshop (Leh) and back.
M&L for rewinding, repairing, servicing and testing of the 12.5 HP Submersible motor of the submersible (wet type winding) induction motor with existing size and type copper conductor wires suitable for the motor of 415 volts 3 phase AC supply. The size of the winding wire will be that of the existing winding wire etc. including replacement of thrust bearing 01 No, water seal all as required and complete all as specified and directed. NOTE : Cost factor of labours for servicing & fixing of parts shall be deemed to be included in unit rate. However worn out & unserviceable parts to be replaced will be measured and paid separately as supply only as under.
Upper/lower level spl type GM bush bearing.
Sand Guard of motor
Stainless steel sleeve for pump.
Impeller made of Gun metal for pump
Pump shaft stainless steel upto 5 stage
Seal ring made of Gun metal
Discharge bush made of gun metal
Suction bush made of gun metal
Pump body bush made of gun metal
CI stage bowl
Housing Head Complete Front/Rear
SS Pump motor coupling as per sample
SS stud nut
L Key bolt
M&L for making connection of PP-R distribution branch with PP-R main of following sizes by providing and fixing tee including cutting and making fusion joint of size 50 to 75mm etc complete all as specified and directed.
M&L for making connection of PP-R distribution branch with PP-R main of following sizes by providing and fixing tee including cutting and making fusion joint of size 16 to 40mm etc complete all as specified and directed.
S&F in repair tracer / antifreezing cable required to keep the pipe warmup to avoid freezing for PPR Pipe, DI pipe, GI pipe etc. complete all as specified and directed.
S&F in replacement Rubber sheet 2mm thick for Pipe Line Joint Packing complete all as specified and directed.
S&F in replacement of damaged nitrile insulation 19mm thick over PPR/GI pipe of 20mm bore size complete all as specified and directed.
S&F in replacement of damaged nitrile insulation 19mm thick over PPR/GI pipe of 32/40mm bore size complete all as specified and directed.
S&F in replacement of damaged nitrile insulation 19mm thick over PPR/GI pipe of 50mm bore size complete all as specified and directed.
S & F heating element of 6 KW complete all as speciifed and directed.
S&F in repair 3 layer PPR Polypropylene random copolymer pipes SDR 7.4 & SDR 11 UV of 20 mm bore stablished and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass thereaded polypropylene random fittings to be laid in trenches/wall/floor complete all as specified and directed. Note all connected fittings like elbow,tee,reducer coupler will be count in RM
All as per item no 14 here-in-before but size of pipe 32 mm bore complete all as specified and directed.
All as per item no 14 here-in-before but size of pipe 40 mm bore complete all as specified and directed.
All as per item no 14 here-in-before but size of pipe 50 mm bore complete all as specified and directed.
S&F in repair 3 layer PPR Gate valve 32 mm bore complete all as specified and directed.
S&F in repair 3 layer PPR Gate valve 20mm bore complete all as specified and directed.
S&F in repair 3 layer PPR Gate valve 40 mm bore complete all as specified and directed.
S&F in repair 3 layer PPR Gate valve 50mm bore complete all as specified and directed.
Excavation in trenches exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in any type of soil complete all as specified and directed.
Returning, filling including spreading leveling watering and well ramming in layers not exceeding 25mm in any type of soil complete all as specified and directed.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point.
S&F in repair GI tubing 15mm dia galvanized medium grade laid in trenches including all necessary fittings clamps etc complete and connecting to existing system incl taking down old one complete all as specified and directed.
All as per Srl item No.22 here-in-before but 20mm dia pipe
All as per Srl item No.22 here-in-before but 25mm dia pipe
All as per Srl item No.22 here-in-before but 40mm dia pipe
All as per Srl item No.22 here-in-before but 50mm dia pipe
S&F in repair 15mm dia gun metal gate valves with iron wheel head screwed both ends for GI pipe.
All as per Srl item No.23 here-in-before but 20mm dia
All as per Srl item No.23 here-in-before but 25mm dia
All as per Srl item No.23 here-in-before but 40mm dia
All as per Srl item No.23 here-in-before but 50mm dia
S&F in repair sluice valve of size 100 mm bore ISI marked,flanged ends drilled pressure rating PN-1.6 conforming to IS 14846-2000 having stainless steel spindle with cast iron operational wheel at top complete all specified and directed.
S&F in replacement Non return sluice valve, heavy duty, of size 100 mm dia, ISI marked for CI/DI line including flange joints complete all specified and directed.
S&F in repair automatic star delta starter 415 volts 3 phase suitable for 12.5 HP motor complete all as specified and directed.
S&F in repair automatic star delta starter 415 volts 3 phase suitable for 20 HP motor complete all as specified and directed.
Supply only heavy duty PVC flexible pipe of dia 20 mm of length 30 meter complete all as specified and directed.
Deduct Credit for Demolished/Dismantled material Rs (-) 37,935.00 (Minus) as listed in Schedule 'A' Part-II (Credit Schedule) Note : Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the 'Contract Sum'.
KASHMIR FAIR DEAL SERVICES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .