| 1 | L1₹20.8 LAccepted-AOC ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹24.4 L+₹2.5 L (11.2%)Rejected-Finance 1170 BENGALI MOHALLA NEAR PRABHAKAR HOSPITAL AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹25.7 L+₹3.7 L (17.0%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹26.6 L+₹4.6 L (21.1%)Rejected-Finance 601 6TH FLOOR MANGOOR VALLEY NEAR GURUDWARA MANGOOR HILLL VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹26.8 L+₹4.8 L (22.0%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
27 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Halwara
GE (AF) Halwara
REPAIR MAINT OF LT INFRASTRUCTURE AND ELECTRONIC GADGETS OF DOMESTIC AND TECH AREA AT AF STN BARNALA UNDER GE (AF) HALWARA
2021_MES_498032_1
GE/HAL-63/2021-22
Open Tender
Civil Works
Item Rate
273 days
GE (AF) Halwara
MES ENLISTED CONTRACTORS CLASS D CATEGORY b i
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Halwara
₹60,000
Yes
15 Feb 2022
29 Dec 2021
29 Jan 2022
29 Dec 2021
27 Jan 2022
13 Jan 2022
60 days
Amount
M&L for excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exeeding 1.5 m deep, getting out the excavated earth complete all as specified and directed.
M&L for removal of excavated material such as soils n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Returning filling in, and including spreading and leveling in layers not exceeding 25 cm thick complete all as specified & directed.
M&L for sand cushioning using dry clean sand for protection of underground cable, consolidated and compacted complete all as specified and as directed. Note : Punned thickness shall be measured for payment.
M&L for well burnt old size sub Class ‘B’ bricks, laid flat, in trenches for cable protection complete all as specified and as directed.
M&L for taking out any size defective cable XLPE/PVC sheathed 1100 volt grade heavy duty armoured with aluminium conductor of any cross sectional area from trenches, from wall/poles/under floor etc, shifting serviceable cable for relaying or removing the unserviceable cable complete all as specified and directed. Note : (i) Excavation and earth work shall be measured and paid for separately (ii) Unit rate of this item is also includes the removal of brick/tile as cable protection, GI pipe and cable joint etc. and nothing extra shall be admissible on this account. (iii) After taking out the cables from the trench, serviceability of cable shall be checked by the contractor in presence of the Engr-in-Charge and nothing extra shall be paid on this account.
Supply and laying XLPE insulated, armoured, heavy duty, 1100 Volts grade aluminium conductor cable cross sectional area 10 Sqmm, 4 core in trenches or fixed to wall / passing through pipe / pole and testing compete all as specified and directed Note : (i) Excavation & earth work, Brick protection and sand cushining shall be measured and paid for separately,
All as per description of item No. 7.00 here-in-before but cross sectional area 10 sq mm, 2 core
All as per description of item No. 7.00 here-in-before but cross sectional area 16 sq mm, 4 core
All as per description of item No. 7.00 here-in-before but cross sectional area 25 sq mm, 4 core.
All as per description of item No.7.00 here-in-before but cross sectional area 35 sq mm, 3.5 core
All as per description of item No.7.00 here-in-before but cross sectional area 50 sq mm, 3.5 core .
All as per description of item No.7.00 here-in-before but cross sectional area 70 sq mm, 3.5 core
All as per description of item No.7.00 here-in-before but cross sectional area 95 sq mm, 3.5 core
All as per description of item No.7.00 here-in-before but cross sectional area 185 sq mm, 3.5 core
S&F in replacement including testing and commissioning outdoor type factory made powder coated AMF Panel Board cubical type, over all size not less than 1000x750x400 mm suitable for DG set 62.5 KVA capacity, with suitable size 4 Nos copper bus bar 400 amps, having locking arrangments floor mounted free standing weather proof panel fabricated out of suitable sized angle iron and flats and covered with 3 mm thick CRCA sheet duly pretreated in seven tank process for de-greasing , de-rusting & phosphated painted with 2 coats of primer paint then the panel surface shall be finished and then painted with final coat of epoxy based powder coated paint.Panel shall be compartmentrised with rubber gasketed hinged door. Panel shall be having only one side opening for installation of separate cable alleys, busbar chamber and switchgear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming & outgoing cables. Panel have CT 5/400 Amps - 03 Nos, Digital Ammeter 0-300 Amps, Digital Voltmeter 0-500 Volts, Phase Indicator LED (RYB) - 03 Nos. A clear space of 200mm to be kept from floor level for switchgear compartment. Extended busbar links/ terminals to be provided for connecting cables. Air ventillation louvers to be provided for heat dissipation with earthing terminal at each end of the panel. suitable sized knock-out holes consisting of the following:- a) Power contactor-4 pole, of suitable current rating with thermal overload relay - 02 Nos (for alternator and mains) b) HRC fuse of suitable current rating for short circuit protection c) Microprocessor based AMF module incorporating functions:- - Supply failure timer - Restoration timer - 3 Impulse automatic engine start/ stop logic - Mains/ Generator Voltage & Frequency sensing d) copper bus bars of suitable capacity with incoming/ outgoing terminals e) Instrument fuses duly wired and ferruled f) MCCB 63 KVA rating 4 pole with overload and short circuit protections - 02 No's (for alternator & mains) g) Current Transformers of suitable rating h) A separate by pass systeml to bypass mains & DG set with change over switch (02 Nos) of cpacity 200 Amps 4 pole I) Digital Frequency meter,Digital Multifunctional metre,Push buttons for manual start stop,Indicating Lamp for DG Set Load on or Mains Load On, Fail start. J) complete wiring for functioning of DG Set on auto mode from DG set to AMF panel. Note:- OEM rep will install complete panel at site and wiring from DG set panel to AMF panel should be checked and connected by OEM rep.
S&F, installation, testing and commissioning LT Panel in replacement, Outdoor type, dust and vermin proof, totally enclosed, platform mounted, factory made having front openable shutter with locking arrangement made out of CRCA steel sheet 3.15 mm thick with MS angle iron frame work of size 40 mm x 40 mm x 6 mm thick, duly painted all as specified including necessary foundation bolts, PCC (1:2:4), type B-1 platform of suitable size for mounting the panel, suitable for 415 Volts, 50 Hz, three phase, 4 wire system with suitable insulated aluminium busbar of capacity not less than 600 Amps and shall be complete with internal wiring with copper conductor and including the following accessories(for alternate site):- (A) Main Incoming (i) MCCB conforming to IS:13947 (Part-II), IEC-947, 4 pole, 250 Amps, 415 volts, 50 Hz, rupturing capacity 36 KA, with adjustable thermal and adjustable magnetic setting - 01 No. (iii) LED Multifucntional Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs (iv) LED indicating lamps with colour Red, Yellow, Blue, Main ON - 01 Set (B) Main Outgoing (i) MCCB conforming to IS:13947 (Part-II), IEC-947, 4 pole, 63 Amps, 415 volts, 50 Hz, rupturing capacity 36 KA, with adjustable thermal and fixed magnetic setting - 05 No. (For guard room,+logistic+radar head+MT+Spare) (ii) MCB FP 32 Amps, 10 kA, C Curve - 02 Nos (Street light timer)
S & F in replacment of street light timer box company made, three phase for 8 KW light load comprising of nature switch, contactor and MCB housed in a enclosure and mounted on angle iron plateform with PCC work on ground complete all as specified and directed by Engineer-in-Charge.
M&L for isolating, disconnecting and transporting the Servo voltage stabilizer of capacity 600 KVA to workshop for repair maint , strip opening of stabilizer for inspection and acertaining the defects for repair & cleaning, servicing all serviceable acessories including reassembling after repair, preparation of surfaces and painting with two coats of synthetic enamel paint of approved colour and marking SM/MES No., transporting back to site, re-installation and testing on load complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair PCB Card/Plate for automatic voltage correction suitable for servo stabilizer of capacity 600 KVA as per existing type and make complete all as specified and directed by Engr-in-Charge.(make of servo is Instruments and Equipment Co.)
M&L for replacment of control supply transformer suitable for 600KVA servo voltage stabilizer as per existing make and capacity complete all as specified and directed by Engr-in-charge.
Taking down old burnt out copper winding and replacement of same for stabilizer oil immersed type of capacity 600 KVA by using suitable gauge super enamelled copper conductor as per existing winding complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair copper dimmer gear set for automatic voltage correction capacity 600 KVA with as per site requirement for type and make complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair micro limit switch with cam lever complete for servo stabilizer of capacity 600 KVA as per site requirement for type and make complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair of servo motor synchronous type for automatic voltage correction suitable for servo stabilizer of capacity 600 KVA as per site requirement for type and make complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable control wiring and replacement of control wiring using suitable gauge super enamelled copper conductor as per existing winding for stabilizer transformer oil immersed type of capacity 600 kVA complete all as specified and directed.
Supply and fix in repair of Control Transformer heavy duty sutiable for servo stablizer of 600 KVA capacity, complete all as specified and directed by Engr-in-Charge.
M&L for replacment of RC network card of 600 KVA capacity servo stabilizer as per existing make and capacity coplete all as specified and directed by EIC.
Supply of insulation transformer oil toping up into voltage stabilizer of different capacity complete with superior quality insulating oil BDV not less than 50 KV all as specified and directed by Engr-in-Charge.
Dehydration of transformer oil for LT/HT AVR/Servo voltage stabilizer upto BDV not less than 50 KV all as specified and directed by Engr-in-Charge.
M&L for boring under road crossing of size 80 mm dia at suitable depth not less than 1 mtr by using machinery / equipments complete without damaging the surface for passing pipes / cables etc including removing excavated soil to a distance n exc 50m and providing 80mm dia light grade GI pipe with fittings in boring for passing cables etc complete all as specified and as directed. Note : (i) Location of boring holes shall be decided by the Engr-in-Charge as per requirement, nothing extra shall be payable on account of variation in length of crossing of road etc. (ii) During boring soil strata may be changed, hence nothing extra shall be paid to the contractor for boring of holes through different strata/different type of soil. Tenderer is hereby advised to keep in mind this aspect while quoting his rates.
S&F in repairs LT cable route marker / LT cable joint marker made of Jodhpur stone 250mm x 150mm size, 900mm long, with top of oval shaped, two sides engraved with letters 'LT cable', letters painted with approved paint, embedded in ground including necessary excavation and earthwork complete all as specified and directed.
M&L for earthing complete with GI earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.50 Mtr below ground level. The earth plate to be connetced with GI earthing strip of size 32mmx6mm thick by means of brazing between GI strip and earth plate min 45 cm in vertical length and GI strip also to be joined by brazing only. The GI earthing strip to be protected by galvanised iron pipe 40 mm bore (medium grade) up to ground level and there after with 40mm dia HDPE pipe up to test point. Earthing shall include for providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) up to 90 cm all around earth plate further filled with 60 cm thick Tibba sand and 2nd layer with 30 cm of Magnesium sulphate powder (compact thickness ) , 3rd layer with sand up to the ground level. Earthing shall also include for providing concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work and testing complete all as specified and directed by Engr-in-Charge. .
S&F in replacement GI strip 32mm x 6mm in ground / laid in floor / fixed to walletc complete all as specified and directed. Note :- Excavation and earth work shall be measured and paid separately.
Dismantling and taking out the old stay assembly complete including demolition of plain cement concrete all as specified and directed. Note :- (i) Unit rate of this item includes the loose/ disconnect the all accessories which are connected to stay assy including neccessary excavation as directed.
M&L for stay assembly complete with accessories as shown in electrical plate No1 including GI adjustable stay rod of 16 mm dia GI stay wire of size 7/4 mm including stay clamps, loop type insulators etc all as specified and directed. Note :- Earth work and PCC work shall me measured and paid separately.
Supply and laying in replacement galvanaised steel tube light grade 50 mm dia with fittings complete all as specified and directed.
Supply and replacement of silica gel contains in the breather assembly complete all as specified and directed.
M&L in replacement of danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size all as specified and directed.
All as per item No 40 above but for HT, 25 x 20 cm size
M & L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation for poles, filling of mass concrete complete all as specified and as directed
M & L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in coping for old and new poles including form work complete all as specified and as directed by Engineer-in-Charge.
M & L for cleaning and preparation of steel surfaces of existing dull painting of transformer outdoor type including radiators, cooling ducts, vent pipes, condensor etc and applying two coats of synthetic enameled paint (heat resistant type) according to to IS colour code by spray machine including writing MES /SM No(letter size shall be 50 mm size) in capital letters s on body for capacity upto 100 KVA transformer outdoor/indoor complete all as specified and directed
All as per item No: 44 above but capacity above 160 KVA and upto 630 KVA.
M&L for painting of steel tubular pole 9.0 m long, by applying two coat of alluminum paint after scraping/brushing and cleaning the rust on pole and cross arms. Aluminium painting will be done on pole above 1.5 m height from ground level and balance 1.5 m from ground level will be painted by alternate layer of red and white enammelled paint (30 cms each) pole No will be written on pole by black paint in yellow circle of 150 mm dia complete all as specified and directed.
M&L for painting with two coats of synthetic enamel paint on RCC pole from 1.5 mtr above the GL and balance 1.5 m from ground level will be painted by synthetic enamel paint in alternatively black and white strap of 30 cm after scraping /removing the existing paint and the preparation on the surface of RCC LT pole. Pole No will be written on pole by black paint in yellow circle of 150 mm dia complete all as specified and directed.
M & L for cleaning and preparation of surfaces of any existing E/M equipment of any size and shape and applying one coat of synthetic enameled paint (heat resistant type) for writing Mechine no,and writing MES /SM No. in capital letters of suitable size on body and all as specified and directed. Note : Contractor's may visit the site to see the sizes of equipment before quoting their rates. Nothing extra shall be admissible on this account.
M&L for trimming of tree branches on both sides of HT /LT aluminium conductor overhead complete all as specified and directed. Note : (i) Cutting branches shall be dumped outside the Air Force premises . (ii) Contractor shall provide the ladder of required height including T&P to his worker and nothing extra shall be paid on this account.
S&F in replacement of onload change over switch 100 Amps 4 pole 415 Volts complete all as specified and directed.
Taking down/removing existing broken/damaged PCC/Steel poles from site complete all as specified and directed by Engineer-in- Charge. Note: Damaged poles shall be removed from site as per direction of Engineer-in- charge
M&L for steel tubular swaged pole type 410 SP-31 (9.00 metres long) complete with cast iron base plate, finial taper plug, bolts, nuts & screws complete all as specified and directed.
Taking down old unservicable timer switch with all accessories like contractor, MCB etc complete all as specified and directed.
S&F Astronomical timer switch 110/240 volts Make : Havells Cat No DHTKW01016 or equivalent as approved by GE.
S&F in repairs Power contactor 63 Amp 4 pole 415 V 50 Hz model MCX 12 with front mounting auxiliary contacts 2 No+ 2 NC rating Make : L&T Cat no CS97014 or equivalent as approved by GE.
S&F in repairs MCCB of 63 Amps 4 Pole 415 Volt rupturing capacity 16 KA connection with proper size of thimbles complete all as specified and directed.
M&L for cleaning of entire cable duct (any size) by removing HT/LT cables from the duct , removing waste materials including sand and cleaning the entire duct for plastering complete all as specified and directed.
M&L for 10mm thick cement plaster in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished fair and even without using extra cement complete all as specified and directed.
M & L for cleaning and preparation of steel surfaces of existing dull painting of rolling shutter and applying two coats of synthetic enameled paint by spray machine complete all as specified and directed
Taking out rusted/damaged M.S sheet /PCC/RCC duct covers and S&F Fe 410-W (Gde-E- 250) quality- A , Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed.
M & L in repairs MS works, cross arms, bracing, support clamps and back plate fabricated out of structural steel sections including nuts, bolts and washers, welding, bending hot or cold, cutting, drilling holes for bolts in any shape or size as directed and including one coat of red oxide primer, one under coat and one finishing coat of aluminium paint paint complete all as specified and directed.
S&F in replacement of pin type porcelain insulator, vitreous , white brown or green insulator including one galvanised mild steel spindle , two galvanised iron washers and one galvanised iron nut , 150 mm height ,150 mm dia for 11KV grade complete all as specified and directed.
Tracing out fault in 11KV U/G cable with the help of fault tracing machine and rectifying the same with joints as specified and directed to restore the supply complete all as specified. (Note: (i). Joint kit to be measured and paid separately. (ii) Earth work to be measured and paid separately. (III). All other necessary arrangements suitable for locating the faults is deemed to be included in the rate Quotation ed. (iv) T & P required for the entire job shall be provided by the contractor at his own end and nothing extra shall be admissible on this account )
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm 3 core complete all as specified and directed.
All as per item Sl No 64 here in before but for cross sectional area 120 sq mm, 3 core.
Dismantling existing ACSR conductor of any size/type from PCC/Steel poles including taking down MS works such as cross arms, clamps, hooks, stay etc from overhead line complete all as specified and directed by Engineer-in-Charge.
Supply, stringing and fixing ACSR conductor of any type/size on existing poles including fixing to insulators with binding wire or aluminium taps complete all as directed .
S&F in repairs lightening arrestors expulsion type complete with all fittings, suitable for 11000 Volts grade transmission class, discharge capacity 65KA including brackets, clamps, nuts, washers and connecting to 4mm dia GI earth wire complete all as specified and directed.
M&L for straight through cable joint kit by using M-seal Kastex cable accessories based on cast resin system ie (electrical insulation, mechanical protection and moisture imperviousness to the joint) for LV PVC / XLPE cable up to 50 sq mm x 3.5 / 4 core 1100 volt grade complete all as specified and directed.
All as per item No. 69.00 here in before but size 70 sq mm x 3.5 core
All as per item No. 69.00 here in before but size 95 sq mm x 3.5 core
All as per item No. 69.00 here in before but size 120 to 150 sq mm x 3.5 core
All as per item No. 69.00 here in before but size 185 sq mm x 3.5 core
Supply only MCCB, 25 KA, 4 pole, 400A
Supply only MCCB, 25 KA, 4 pole, 200A
Supply only MCCB, 25 KA, 4 pole, 160A
Supply only MCCB, 25 KA, 3 pole, 200A
Supply only MCCB, 25 KA, 3 pole, 100A
Supply only Indicator lamp RYB
Supply only Volt meter analog type 0-500 volt
Supply only Amp meter Analog type 0-200 Amp With CTS
Disconnecting and taking out of DG set 75 KVA Make :- Mahindra powerol No of Cylinder :- 04 including disconnecting all electrical connections and transporation to work shop and back after carry out necessary repair and replacement of worn out defective parts including preventive maintaince of connected assemblies. Reassembling the same after repairs including testing and commissioning at site complete. including replacement of the following spare parts .(Note :- cost of spare parts to be replaced will be masured and paid seperatly as supply only under Sl items No 84 to 114 of this BOQ but cost of replacement shall be deemed to be included in this item.)
CY Liner VNEF 6500 NEW55 with Grade-I
Bearing conecting rod (Tier I)
O Ring Cylinder Liner
Taper Faced Comp Ring -GK 153P96/88X2.5
Ring Piston Top
Oil Ring Tier-III
Piston 75 KVA
Pin Piston VNEF TCI
CIRCLIP VNEF TCI for Piston
Con Rod Bush
Pipe for Fuel Supply (S.R. 1300)
Radiator Cleaning
Gasket (CPI and Intake Manifold)
Gasket INT MANFOLD RIGID MTG COMMON
Outer AIR Element
Safety Air Element
Mechanical Service Indicator FO
Fan Belt
Water Pump High Flow(80 HP)
Oil Seal
Gasket Oil Sump
Gasket Cylinder Head
Intake Valve for NEW65
Intake Exhaust for NEW65
Fuel Filter
Coolant
Engine Oil
Hose Oil Cooler Pipe to Water Pump
Hose Oil Cooler Pipe ALT
Hose Radiator inlet
Hose Radiator outlet
M&L for repair to fuel injecting pump (FIP) of 75 KVA DG sets of make Mahindra including supply and replacement of element delivery valve,nozzle, delivery valve pin with bearing , deliver valve spring etc and including calibration of pump and injector pressure setting , fitting and testing complete all as specified and directed.
The Rahul Vig
Shivam Engg and fabricators
SHIVANI ENTERPRISES
SANGAM ENGINEERS
SWARN SINGH AND CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .