Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.8 LAccepted-AOC B XXIII 56 A PREM NAGAR SAINGARGH PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹36.9 L+₹15,551.30 (0.42%)Rejected-Finance KRAL PORA BAGH I MEHTAB NEAR MANCHOWA PETROL PUMP DISTRICT BUDGAM 190019 J K | BUDGAM | BUDGAM | J K | 190019 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹38.1 L+₹1.4 L (3.73%)Rejected-Finance | L3 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | SATISH AND CO L1 | CHINAR CONSTRUCTION TRADERS L3 | M/S RATHER CONSTRUCTION CO L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing and commissioning of Vacuum Circuit Breaker of 630 Amps, at 11 KV rated, fault level of 25 KA for 3 sec, totally enclosed, air insulated metal clad housing, horizontal isolation, vermin proof, fully interlocked horizontal draw out type operation sequence 0-0.3 sec-CO-3 min - CO having double isolation, both the incomers shall be interlocked (Electrically) with Bus coupler complete all as specified and directed. | 1 | Each | 6,53,999.3 ₹6,53,999.3 | 5,20,000 ₹5,20,000 Lowest | 7,00,000 ₹7,00,000 |
| 1.01The offered panels shall be tested for IAC level of min 25 kA/1s, complete all as specified and directed and consisting of the following for incoming :- (i) Manually and motor operated, spring charged (release closing mechanism) trip free type, triple pole truck mounted draw out, Vacuum Circuit Breaker, incorporating mechanical as well as electrical ON/OFF indication. Spring charge/discharge mechanical indication ''OFF'' push buttons for emergency trip (shrouded) test/service position limit switches with min 6 NO/6 NC breaker auxiliary contact in service position, 30/24 volts DC shunt trip coil and strip heaters with thermostat switch. One heater in CT chamber and One heater at VCB chamber to prevent moisture absorption. Rated Volatge level/PF withstand Voltage/Impulse level:12 KV/38 KV/95 KV for the altitude of upto 2000 mtr above MSL. (ii) 630 Amp air insulated but encapsulated copper bus bar tinned coated. (iii) C.T chamber with double wound C.T's 400/200/5A/5A, (separate core for metering and separate core for protection) 15 VA burden, Class 5P 10 for protection and class 0.5 for instrumentation-03Nos. (iv) Voltage Transformer with 3 numbers 1 phase, 3 limbs connected in star, class 0.5 accuracy, 11 KV/ 3/110V/ 3, 100 VA burden, with primary and secondary fuses and isolating plugs. | ||||||
| 1.02(v) Following protection shall be provided:- (a) Microprocessor based 3 Nos. outer elements for over current and one middle earth - fault with IDMT self power relay with shunt trip on 30/24 Volts, DC consisting 3 element overcurrent relay with setting from 50 to 200% and earth fault with setting from 10 to 80%. (b) Anti pumping relay and Master trip relay. (vi) All wiring necessary for the above including inter-connections. The size of the conductor should not be less than 1.5 sq mm copper wire where required. | ||||||
| 1.03(vii) Test termninal box fuses/2A SP MCB, circuit labels, set of phases, indication lamps etc, as per standard practice as under:- (a) Red breaker closer (ON) (b) Green breaker open (OFF) (c) Amber-Auto trip (d) Clear-trip circuit healthy (e) 3 Phase Indication (R, Y, B) (f) Blue spring charged (viii) The following meters are to be provided:- (a) Digital type frequency meter range 45 to 55 Hz. (b) Digital voltmeter range 0-15 KV and suitable for 110 AC square dial with shrouded terminal & protection fuses. (c) Digital Ammeter 0-100A rating. (d) Power factor meter-Range-0.5 lag to 0.5 lead. (ix) 6 Nos. window annunciation panel with audio and visual indicator as: (a) Over Current and earth fault-02 windows (b) Spares-04 windows | ||||||
| 1.04(x) Power pack unit 220V AC to 24 Volt DC complete with battery backup (maintenance free) for operation of relays including charging equipment 01 set (xi) Control :- T-N-C (Trip, Neutral, Close) Breaker control switch with indication arrangement. (xii)Terminal box with single gland trifucating cable box suitable for 11 KV aluminium XLPE cable of size 3x300 Sqmm for incoming breaker. (xiii) HT Danger Plate (As per specification) (xiv) 2 Runs of not less than 30x6mm earth bus bar shall be provided for full length of the panel. | ||||||
| 2.00 | Supply, Installation, testing and commissioning of Vacuum Circuit Breaker of 630 Amps, at 11 KV rated, fault level of 25 KA for 3 sec totally enclosed, air insulated metal clad housing, horizontal isolation, vermin proof, fully interlocked horizontal drawout type operation sequence 0-0.3 sec-CO-3 min - CO having double isolation complete all as specified and directed. | 2 | Each | 6,19,000 ₹12,38,000 | 5,20,000 ₹10,40,000 Lowest | 6,50,000 ₹13,00,000 |
| 2.01The offered panels shall be tested for IAC level of min 25 kA/1s, consisting of following for Outgoing:- (i) Manually and motor operated, spring charged (release closing mechanism) trip free type, triple pole truck mounted draw out, Vacuum Circuit Breaker, incorporating mechanical as well as electrical ON/OFF indication. Spring charge/discharge mechanical indication ''OFF'' push buttons for emergency trip (shrouded) test/service position limit switches with min 6 NO/6 NC breaker auxiliary contact in service position, 30/24 volts DC shunt trip coil and strip heaters with thermostat switch. One heater in CT chamber and One heater at VCB chamber to prevent moisture absorption. Rated Volatge level/PF withstand voltage/Impulse level:12 kV/38 kV/95 kV for the altitude of upto 2000 mtr. (ii) 630 Amp air insulated but encapsulated copper bus bar tinned coated. (iii) C.T chamber with double wound C.T's 400/200/5A/5A, (separate core for metering and separate core for protection) 15 VA burden, Class 5P 10 for protection and class 0.5 for instrumentation- 03 Nos. | ||||||
| 2.02(iv) Buchholz Relay for transformer feeder - 01 No. (v) Following protection shall be provided:- (a) Microprocessor based 3 Nos outer elements for over current and one middle earth - fault with IDMT self power relay with shunt trip on 30/24 Volts, DC consisting 3 element overcurrent relay with setting from 50 to 200% and earth fault with setting from 10 to 80%. (b) Anti pumping relay and Master trip relay. (vi) All wiring necessary for the above including inter-connections. The size of the conductor should not be less than 1.5 sq mm copper wire where required. (vii) The following meters are to be provided:- (a) Digital type frequency meter range 45 to 55 Hz. (b) Digital voltmeter range 0-15 KV and suitable for 110 AC square dial with shrouded terminal & protection fuses. (c) Digital Ammeter 0-100A rating. (d) Clear trip circuit healthy (e) Blue spring charged | ||||||
| 2.03(vii) Test termninal box fuses/2A SP MCB, circuit labels, set of phases, indication lamps etc, as per standard practice as under:- (a) Red breaker closer (ON) (b) Green breaker open (OFF) (c) Amber-Auto trip (d) Clear-trip circuit healthy (e) 3 Phase Indication (R, Y, B) (f) Blue spring charged (viii) Control :- T-N-C (Trip, Neutral, Close) Breaker control switch with indication arrangement. (ix) Terminal box with single gland trifucating cable box suitable for 11 KV aluminium XLPE cable of size 3x300 Sqmm for incoming breaker. (x) HT Danger Plate (As per specification) (xi) 2 Runs of not less than 30x6mm earth bus bar shall be provided for full length of the panel. (xii) Integrated earth switch as required. NOTE FOR ITEM SER NO 1 & 2 : Necessary drawing shall be got approved from accepting officer before placing order and testing at site shall be carried out by representative of accepting officer. | ||||||
| 3.00 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 120 Sqmm suitable for earthed system complete all as specified and directed. | 652 | RM | 1,130 ₹7,36,760 | 1,580 ₹10,30,160 | 1,050 ₹6,84,600 Lowest |
Tender Value
₹43.7 L
EMD Value
₹87,316
Closing Date
31 Oct 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col P Canon Anal CWE
HQ 134 WE C/o 56 APO PIN-914134
PROVISION OF LOAD BREAK SWITCHES ALONG WITH 11 KV BAY EXTENSION AND ALLIED INFRASTRUCTURE AT 33 KV MAIN RECEIVING STATION AT OAF SRINAGAR UNDER GE 970 EWS
2025_MES_734568_1
134WE-75(T)/2025-26
Open Tender
Civil Works - Others
Item Rate
180 days
GE 970 EWS
As per tender documents
8 documents required · 8 mandatory
₹500
GE 970 EWS
₹87,316
19 Nov 2025
10 Oct 2025
3 Nov 2025
10 Oct 2025
31 Oct 2025
24 Oct 2025
10 Oct 2025 - 17 Oct 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
PS75T.pdf
Tender Documents • 1.06 MB
BOQ_822528.xls
BOQ • 10.52 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .