Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 LAccepted-AOC WARD NO 02 LAKHUWALI PO THE PILIBANGAN DISTT HANUMANGARH RAJASTHAN 335803 | HANUMANGARH | RAJASTHAN | 335803 | L1 | Accepted-AOC L1 | |
| 2 | L2₹13.9 L+₹89,348.50 (6.89%)Rejected-Finance 270 ADARSH NAGAR ROORKEE HARIDWAR 247667 | HARIDWAR | UTTARAKHAND | 247667 | L2 | Rejected-Finance Other than lowest Bidder | |
| 3 | L3₹15.4 L+₹2.4 L (18.5%)Rejected-Finance | L3 | Rejected-Finance Other than lowest Bidder |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
29 Apr 2020, 6:00 pmClosed
GE (N) Bikaner
GE (N) Bikaner MIl Stn Bikaner
Repair/maint of summer appliance and deep freezer, water cooler and AC at AGE MFFR under GE (N) Bikaner
2020_MES_337063_1
GE (N) BKN-Token/01/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bikaner
Class E and category b (i)
8 documents required · 8 mandatory
₹500
GE (N) Bikaner
₹30,000
Yes
1 Mar 2021
1 Apr 2020
1 May 2020
1 Apr 2020
29 Apr 2020
15 Apr 2020
Amount
Desert Cooler Repair to Desert Cooler by Removing of old paint complete with emery paper and cleaning with scrapper and preparation of internal surfaces & bottom of the desert coolers and apply one coats of black bituminous paint complete all as specified and directed by Engr-in- charge.
All as per item No. 1 here in before but applying one coats of synthetic enamel paint to external surfaces and internal surface in bottom of desert coolers including steel grills, removing of wooden grass pad & refixing the same after necessary work side panel etc complete all as specified and directed by Engr-in- charge.
Taking down carefully old unserviceable water pumps heavy duty of capacity 1/40 HP, 230 volts 50 HZ single in lieu providing new submersible type water pump including necessary wire connection etc, complete all as specified and directed by Engr-in- charge. Make:- Havells/Bajaj/CG.
Taking down carefully fan motor from existing desert coolers and in lieu providing new fan motor 1/6 to 1/8 HP 230 volts, 50 HZ, including replacement of mounting legs & nuts bolts as reqd at site complete all as specified and directed by Engr-in- charge. Make:- Havells/Bajaj/CG.
Taking down carefully fan motor 1/6 to 1/8 HP 230 volts, 50 HZ, from existing desert coolers and refixing the same fan motor after rewinding with super enameled copper wire of existing size complete including replacement of mounting legs & nuts bolts as reqd at site complete all as specified and directed. Make: Milan/chetak.
Taking down the following parts from the existing desert coolers & providing new parts in same possition as listed below- (a) Capacitor for desert cooler 4 MFD 230 volts Make: Asian/Tibcon
(b) GI sheet as per existing guage front grill including nuts bolts and washers suitable for 18/20" sweep desert coolers including necessary wire connection, regulator & on/off switch etc reqd at site, Make-Alka/kinark.
Taking down following part of desert cooler old rusted as under and M & L out of 20 gauge GI plain sheet class-III including cost of riveting welding, nuts and bolts as required accessories for fixing etc complete all as specified and directed by Engr-in- charge. (a) Bottom tank as existing size
(b) Top cover as existing size
(c) Side panels as existing size
(d) Wood wool pad for desert coolers
(e) Supporting jali for desert coolers
(f) Plug Top 3 pin, 5-A, 230 Volt
(g) Plug Top 3 pin, 15-A, 230 Volt
(h) Speed convertor switch
Supply and fixing fan blades made of aluminium for desert cooler as per sample, complete all as specified and directed by Engr-in- charge.
Supply and fixing cable, 3 core, copper conductor size 23/0.0076 for desert cooler complete all as specified and directed by Engr-in- charge.. Make: plaza/finolex/kalinga
Supply only condenser 3.5 MFD complete all as specified and directed by Engr-in- charge.
Replacement of PVC pipe 15 mm for desert cooler including all necessary 'T' joints & clamps reqd at site complete all as specified and directed by Engr-in- charge.
Distributor of PVC for desert cooler with fixing bolt complete all as specified and directed by Engr-in- charge.
Replacement of Elbow of PVC for desert cooler complete all as specified and directed by Engr-in- charge.
S&F in repair float valve suitable for Water cooler (as per sample) complete all as specified and directed by Engr-in- charge.
S&F in repair tap mounting with nipple 1/2" as per sample complete all as specified and directed by Engr-in- charge.
S&F in repair water outlet nipple with washers and check nuts (copper/brass) complete all as specified and directed by Engr-in- charge.
DEEP FREEZER Taking down unserviceable compressor from deep freezer including bushes, gromments, sleeves, washers, mounting rubbers, nuts, bolts terminal cover brazing and clips from existing deep freezers of capacity 320 ltr, complete all as specified and directed by Engr-in- charge. Make: voltas/Usha/Sidhwal/Blue star
Supply and fixing compressor suitable for deep freezer 320 ltr make- Blue star/Gulmarg/Usha, Compressor of make: Emerson Model No. CAJ 34/KCE 444 HAG with necessary accessories including provn of new bushes, gromments, sleeves, washer, mounting rubbers, nuts and bolts, terminal covers, brazing and clips complete all as specified and directed by Engr-in- charge.
Supply and fixing compressor suitable for deep freezer 405 ltr make- Blue star, Compressor of make: Emerson Model No. CAJ 34/KCE 444 HAG with necessary accessories including provn of new bushes, gromments, sleeves, washer, mounting rubbers, nuts and bolts, terminal covers, brazing and clips complete all as specified and directed by Engr-in- charge.
Cleaning of complete deep freezer existing gas system with CTC, testing of leakage, charging of refrigerant with R-134 (a) after rectification of leakage in existing deep freezer of 320 /405 ltrs capacity of make and model as per existing complete all as specified and as directed.
Supply in replacement of AC Axial cooling Blower Exhaust rotary Fan for deep freeze of size 4.75"(12x12x3.3 cm), Block complete all as specified and as directed.
Water Cooler Taking down unserviceable compressor form deep freezer including bushes, gromments, sleeves, washers, mounting rubbers, nuts, bolts terminal cover brazing and clips from existing water coolers of Make: voltas/Usha/Sidhwal/Blue star 60/120,150/180.
Supply and fixing new hermetically sealed unit (compressor) of following Makes and model including provision of new bushes,grommets, sleeves , washers, mounting rubers nuts boltes,terminals,covers,brasing and clips in the existing Water coolers 60/120 ltrs of Make :- Blue star /usha /voltas with necessary accessaries and all as directed.
all as per item No. 23 here in before but for 150/180 ltrs capacity complete all as specied and as directed by engr -in-charge.
Taking down carefully existing internal wiring of existing water coolers and in liu provision of new internal wiring of with PVC insulated copper conducter cable of size 40/ 0.0076 sq mm including replacementof main lead 03 meter long, terminals clips, thimbles, 03 pin plug top 15 amps & soldering extra compelte all as specified.
Taking down carefully the following accesseries/parts from the existing water coolers and in lieu providing new acccesories/parts in these water coolers as per details given blow:- (a) filter copper. .
(b) Capilary tube of copper existing size as per sample.
(c) PVC water water out let pipe 15 mm dia including clamps.
(d) Drain pipe of same quality,length and dia meter as per existing.
(e) Dip tray made out of aluminium 22SWG existing shape and size including outlet bend and filter including necessary accessories for conecting drain pipe.
Supply and fixing new condenser size 12"x12"/12"x15"
Cleaning of complete existing gas system with CTC, testing of leakage, charging of refrigerant with R-134 (a) after rectification of leakage in existing water cooler complete all as specified and directed.
Removing of old rusted warn out portion of sheet/angle/flat iron from base, front and top etc. of the water cooler/ air conditioner and providing new mild steel sheet, angle iron/MS flat including necessary bending, welding. reveting etc. including making provision for mounting of fan motors, compressor, and condenser complete all as specified.
Complete removing old faded paint from steel surfaces of water cooler by scrapers making the surface smooth including filing material and painting the surface of any description over 10 Cm in width of girth not otherwise described with one coat of red oxide primer and two coats of synthetic enamel paint complete all as specified and directed.
Taking down defective fan motor from water coolers, dismentling the old burnt winding from the motor and rewinding with super enameled copper wire as per existing size. Make : Milan/Chetak including replacement of shaft, boshes, mounting rubbers, nuts, bolts and refixing after reassembling and testing in existing water cooler for under mentioned fan motors :- (Note : The unit rate coated shall be deemed to be included replacement of minor spares such as rubbers, nuts, washers, insulating materials and clams) (a) Fan motors of capacity 1/16 HP 230 Volts single phase.
(b) Fan motors of capacity 1/32 HP 230 Volts single phase.
Supply in replacement of fan blade for water cooler motor made out of aluminium as per sample
Taking down carefully fan motor from existing water coolers and in lieu providing new fan motor 1/35 HP 230 volts, 50 HZ, including replacement of mounting legs complete all as specified and as directed. Make : Usha/Bajaj/CG
Taking down carefully fan motor from existing water coolers and in lieu providing new fan motor 1/16 HP 230 volts, 50 HZ, including replacement of mounting legs complete all as specified and as directed. Make : Usha/Bajaj/CG
Taking down carefully fan motor from existing water coolers and in lieu providing new fan motor 1/10 HP 230 volts, 50 HZ, including replacement of mounting legs complete all as specified and as directed.
Taking down carefully fan motor from existing water coolers and in lieu providing new fan motor 1/25 HP 230 volts, 50 HZ, including replacement of mounting legs complete all as specified and as directed.
S & F push cock (stainlees steel) for water cooler as per sample existing.
S & F thermostat for water cooler as per sample existing.
S & F relay with OLP suitable for water cooler existing as per sample.
S & F runing capacitor 36 MFD. Make :- Tibcon/Sharda/Epcos
S & F runing capacitor 60/80 MFD. Make :-Tibcon/Sharda/Epcos
S & F runing capacitor 80/100 MFD. Make :- Tibcon/Sharda/ Epcos
S & F runing capacitor 100/120 MFD. Make :- Tibcon/Sharda/ Epcos
S & F runing capacitor 10MFD. Make :- Tibcon/Sharda/Epcos
S & F runing capacitor 15MFD. Make :- Tibcon/Sharda/Epcos
S & F runing capacitor 40/60 MFD. Make : Tibcon/Sharda/Epcos
Supply and fixing cable, 3 core, copper conductor size 40/0.0076 for water cooler. Make: plaza /finolex/kalinga
Air Conditioner Taking down unserviceable compresor 2TR capacity from the window/split AC of any make and supply and fixing new compresor 2 Ton capacity of including bushes, grommets, sleeves, washers, mounting rubbers, nuts, bolts, terminal covers, brazing and clips from existing AC complete all as specified and as directed.
All as per srl Item No. 48 here-in before but for window type AC 1.5 TR capacity of any make as per existing complete all as specified and directed by Engr-in- charge.
Cleaning of complete existing gas system with CTC, testing of leakage, charging of refrigerant with R-134 (a) after rectification of leakage in existing window/split type air conditioner of 1.5/2 TR capacities of make and model as per existing complete all as specified and as directed.
Taking down unserviceable fan motor of any capacity from the window type air conditioner 1.5/2 TR capacity and dismantling old and unserviceable burnt winding wire and rewinding with super enameled copper wire of existing guage and size including heat varnishes replacement of shaft, bearing and bush complete all as found unserviceable after opening complete all as specified and required and as directed.
Removing of existing window/split type AC 1.5/2 Ton capacity mounting, cleaning of evaporator and condenser with alkaline based solution, washing of AC, oiling of fan motor and refixing on mounting including provn for making opening air tight and dust proof including testing and commissioning complete all as specified and directed by Engr-in- charge.
S & F running capacitor 45 MFD Make : Tibcon/Sharda/Epcos
S & F running capacitor 60 MFD Make : Tibcon/Sharda/Epcos
S & F running capacitor 50 MFD Make : Tibcon/Sharda/Epcos
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps complete complete all as directed.Make: Havells/Legrand/HPL
S & F PCB (Printed Circuit Board) of window/split type capacity 1.5/2 Ton all as specified and as directed.
Replacement of remote control of 1.5/2 Ton window/split type AC of any make/type all as specified and as directed.
Taking down carefully the following parts from the existing AC and in lieu providing new accessories/parts as per existing and complete overholling of AC 1.5/2 ton capacity complete all as specified and directed by Engr-in- charge. (Note- Accessories/parts paid saperately under relevent items ) (a) PVC filters for AC (window/split)
(b) Contactor for split AC
(c ) Starting relay for AC
VOLTAGE STABILZER Dismentling of unserviceable stabilizer from main connection of any size/ KVA and strip opening for checking of defects complete all as specified and directed by Engineer-in-Charge.
Replacement of burnt out transformer and S&F new transformer of 5 KVA voltage stabilizer if any make.
All as per item No. 61.00 above but 4 KVA
All as per item No. 61.00 above but 3 KVA
All as per item No. 61.00 above but 2 KVA
All as per item No. 61.00 above but 1 KVA
Replacement of burnt out wiring and S & F new wiring with proper size of voltage stabilizer of any size / KVA with single core cable copper conductor suitable size complete all as specified and directed by Engr-in- charge.
S & F in replacement volt meter (0-300) volts suitable for 5/3/2 KVA complete of Make- AE/IMP/MECO
S&F in replacement relay assembly of voltage stabilizer 4/5 KVA make -vintek/NEC
Supply and laying PVC insulated stranded aluminium conductor cable heavy duty 1100 Volts grade served with an inner sheathing of PVC tape & overall PVC sheathed 06 Sqmm 2 core nominal cross section incl remove unserviceable cable complete all as specified.
Supply and laying PVC insulated stranded aluminium conductor cable heavy duty 1100 Volts grade served with an inner sheathing of PVC tape & overall PVC sheathed 10 Sqmm 2 core nominal cross section complete all as specified.
Taking down sub main wiring and Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable of size 2x6.0 sq. mm +1x4.0 sq. mm earth wire in suitable PVC conduit complete all as specified.
Taking down sub main wiring and Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable of size 2x4.0 sq. mm +1x2.5 sq. mm earth wire wire in suitable PVC conduit complete all as specified.
Supply and laying PVC copper conductor cable 4 sqmm 3 core suitable for service connection incl remove unserviceable cable complete all as specified.
S&F Sheet metal enclosures MCB DB SPN 4 way ,double door, with 200 amp rated busbar 240 VAC incl taking down unserviceable DB complete all as specified (Make - Legrand/Havells/Siemens)
S&F Sheet metal enclosures MCB DB SPN 2 way, 230 Volt incl taking down unserviceable DB complete all as specified (Make - Legrand/Havells/Siemens)
S&F MCB SP 6 to 40 amps 230 volt, 10 KA breaking capacity C curve incl taking down unserviceable SP complete all as specified (Make - Legrand/Havells/Siemens)
S&F Isolator DP 32 Amps 230 Volt incl taking down unserviceable DP complete all as specified (Make - Legrand/Havells/Siemens)
S&F MCB SPN 40 Amps 230 Volt incl taking down unserviceable SPN complete all as specified (Make - Legrand/Havells/Siemens)
S&F MCB SPN 63 Amps 230 Volt incl taking down unserviceable SPN complete all as specified (Make - Legrand/Havells/Siemens)
S&F in replacement of TP 63 Amps 415 Volt incl taking down unserviceable TP complete all as specified (Make - Legrand/Havells/Siemens)
S&F in replacement of MCB TPN 63 Amps 415 Volt incl taking down unserviceable TPN complete all as specified (Make - Legrand/Havells/Siemens)
Material and labour Earthing complete with galvanised iron earth plate electrode of size 60 x 60 x 0.60 cm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI wire 4 mm dia (upto the cross arms) by means of GI bolts/nuts/washers, protected by 15 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI light grade pipe for watering and including funnel, wire mesh,RCC cover & frame, PCC (1:3:6) type C2 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified & shown in electrical plate No. 3 of SSR Part – I. (Note:- The unit rate includes earth lead upto 7.5 metre length from top of earth plate.)
S & F Switch socket combination 2 in 1, 5 A flush type 5 Amp five pin complete with one PT switch 5 amps on independent board, including wooden box for desert cooler complete all as specified and directed.
All as per item No 82.00 here in before but for 15 Amps socket outlet with PT switch independent including wooden box for for water coolers/AC/Power complete all as specified and directed.
Ceiling Fan Taking down ceiling fan for repair/servicing i.e. winding/greasing/oiling etc., 1200/1400 mm sweep, of any make and any type model, sealing cable end with tape, dismandling the blades, removing fan and deposit the blades/motor to store for repairing/servicing complete all as specified and as directed by Engineer-in-charge. ( Note:- Contractor will be deposit of ceiling fan for repair/servicing i.e. winding/greasing/oiling etc. in AGE MFFR store yard)
Hanging only ceiling fan after greasing/ oiling and connecting up the point using cable from ceiling rose to fan complete all as specified and as directed by Engineer-in-charge.
Re-winding of ceiling fan new model of size 1200 mm sweep with super enameled copper winding wire of gauge as per existing size/No of wire conforming to IS,including vernishing the motor windings with best quality varnish complete all as specified and as directed by Engineer-in-charge. Note:- Contractor will be arrange required all T&P repair for ceiling fans, repair/servicing i.e. winding/greasing/oiling in AGE MFFR store yard)
Ditto all as per item No. 86 here in above but new model ceiling fan of size 1400mm sweep complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of ball bearing of size/No. 6201 conforming to IS complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of ball bearing of size/No. 6202 conforming to IS complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of ball bearing of size/No. 6203 conforming to IS complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of brass bush suitable for ceiling fan of any make and model conforming to IS complete all as specified and as directed by Engineer-in-charge
S&F in replacement of broken bottom cover (bowl) of suitable for ceiling fan of any make and model complete all as specified and as directed by Engineer-in-charge
S&F in replacement of shaft for ceiling fan as per existing size and shape complete all as specified and as directed by Engineer-in-charge
Taking down and dismantling of exhaust fan 250mm/350mm/450mm sweep of any make and model, opening the cover, separating the rotor and startor assembly, locating the fault and maing the fan in fully serviceable condition including replacing the defected worn out screw, flexible wire size 23/0.0076, oiling/greasing the fan and re-assembling & fixing the same and testing complete to the entire satisfaction of Engineer-in-charge. ( Note:- Contractor will be deposit of ceiling fan for repair/servicing i.e. winding/greasing/oiling etc. in AGE MFFR store yard)
Re-winding of exhaust fan 250 mm sweep with super enameled copper winding wire as per existing size conforming to IS including varnishing the motor windings with best quality varnish complete all as specified and as directed by Engineer-in-charge
Re-winding of exhaust fan 350 mm sweep with super enameled copper winding wire as per existing size conforming to IS including varnishing the motor windings with best quality varnish complete all as specified and as directed by Engineer-in-charge Note:- Contractor will be arrange all T&P repair for exhaust Fans, repair/servicing i.e. winding/greasing/oiling in AGE MFFR store yard)
Re-winding of exhaust fan 450 mm sweep with super enameled copper winding wire as per existing size conforming to IS including varnishing the motor windings with best quality varnish complete all as specified and as directed by Engineer-in-charge Note:- Contractor will be arrange all T&P repair for exhaust Fans, repair/servicing i.e. winding/greasing/oiling in AGE MFFR store yard)
S&F in replacement of blades suitable size for exhaust fan 250 mm duly approved by Engineer in charge complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of condenser 04 MFD conforming to IS complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of MS shaft for exhaust fan as per existing size and shape complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of MS backside cover for Exhaust fan of any sweep, size and make duly approved by the GE
S&F down rod 45 cm long suitable for 1200/1400 mm sweep of ceiling fan all as required at site and as directed by Engineer in charge.
S&F D clamp with nuts, check nuts, quarter pin and rubber reel suitable for 1200/1400 mm sweep of ceiling fan all as required at site and as directed by Engineer in charge.
S&F PVC canopies (set of two) as required at site and as directed by Engineer in charge.
S&F condenser 2.5 MFD conforming to IS complete all as specified and as directed by Engineer-in-charge.
S&F in replacement stepped/flush type electronic fan regulator on existing laminated sheet as per requirement including taking down old regulator complete all as specified and as directed by Engineer-in-charge.
Taking down unsv louver and supply and fix new louver of exhaust fan of size 300 mm complete all as specified and directed by Engr-in- charge.
Taking down unsv louver and supply and fix new louver of exhaust fan of size 450 mm complete all as specified and directed by Engr-in- charge.
A.S. CONSTRUCTION COMPANY
GS BUILDERS AND ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .