Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.6 LAccepted-AOC | ₹48.6 L | L1 | Accepted-AOC L1 |
| 2 | L2₹49.1 LRejected-AOC N A | FARIDABAD | HARYANA | 121004 | ₹49.1 L | L2 | Rejected-AOC L2 |
| 3 | L3₹49.9 LRejected-AOC | ₹49.9 L | L3 | Rejected-AOC L3 |
| Sl No | Description | Qty | Unit | PLATINUM CO-OP LAB CONT AND CONST SOC LTD L2 | CHAPDUAR LABOUR CO-OPERATIVE CONTRACT AND CONSTRUCTION SOCIETY LTD L3 | M/S CONTRACTOR L1 |
|---|---|---|---|---|---|---|
| 1.00 | Earthwork in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sand stone) including removing, spreading or stacking the spoils within a lead of 75m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm. | 216.2 | Cum | 300 ₹64,858.80 | 500 ₹1.1 L | 142.15 ₹30,732.26 |
| 2.00 | Earthwork in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(a)With earth obtained from excavation of foundation. | 72.06 | Cum | 92.41 ₹6,659.43 | 92.41 ₹6,659.43 | 92.41 ₹6,659.43 |
| 3.00 | Earth work in filling in compound, tank, low land,
ditches etc. with good earth, in layers not exceeding
150 mm. including breaking clods and consolidating
the same by ramming and dressing complete.
(Payment will be made on profile measurement before
and after the work) and after the work (ii) With carried earth arranged by the contractor within a radius exceeding 3 km. but not exceeding 5 km. including the cost of carried earth. | 172.8 | Cum | 500.06 ₹86,410.37 | 500.06 ₹86,410.37 | 500.06 ₹86,410.37 |
| 4.00 | (A) Filling in foundation or plinth by silver sand in
layers not exceeding 150 mm as directed and
consolidating the same by thorough saturation with
water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
(B) Do - by fine sand | 106.14 | Cum | 848.07 ₹90,014.15 | 848.07 ₹90,014.15 | 848.07 ₹90,014.15 |
| 5.00 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. | 347.54 | sqm | 386.14 ₹1.3 L | 386.14 ₹1.3 L | 386.14 ₹1.3 L |
| 6.00 | (I) Cement concrete with graded stone ballast (40 mm size excluding
shuttering)
In ground floor
(A) [Pakur Variety]
(a) 1:3:6 proportion | 35.08 | Cum | 6,641.9 ₹2.3 L | 6,641.9 ₹2.3 L | 6,641.9 ₹2.3 L |
| 7.00 | Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth | 58.44 | Cum | 5,918.48 ₹3.5 L | 5,918.48 ₹3.5 L | 5,918.48 ₹3.5 L |
| 8.00 | Ordinary Cement concrete (mix1:1.5:3) with graded stone chips ( 20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(i) Pakur Variety GROUND FLOOR | 110.31 | Cum | 7,397.47 ₹8.2 L | 7,397.47 ₹8.2 L | 7,397.47 ₹8.2 L |
| 9.00 | Hire and labour charges for shuttering with centering and necessary staging up to 4m using approved stout prop sand thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion ofworks (up to roof of ground floor) (f) 25 mm to 30 mm shuttering without staging in foundation (When the height of a particular floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht.shall be allowed under 12 (e) for every 4 m or part thereof) (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In- Charge. | 276.75 | sqm | 244.32 ₹67,616.05 | 244.32 ₹67,616.05 | 244.32 ₹67,616.05 |
| 10.00 | (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering
in any concrete work | 538.78 | sqm | 432.62 ₹2.3 L | 432.62 ₹2.3 L | 432.62 ₹2.3 L |
Tender Value
Refer Docs
EMD Value
₹97,150
Closing Date
29 Jan 2026, 6:00 pmClosed
DEO, SSM, UD
Karnajora, Raiganj, Uttar Dinajpur
Construction of Additional Class Room at Saharmoni SSK, Nayahat MSK, Patura Bochagari SSK, Uttar Damuriya SSK under Goalpokher - II Block, Uttar Dinajpur.
2026_DSE_989070_1
09 (nine) OF 2025-26(1stCall) SL No- 02 of SSM, Uttar Dinajpur
Open Tender
CIVIL WORKS
180 days
Goalpokher - II Block
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹97,150
Yes
3 Mar 2026
15 Jan 2026
31 Jan 2026
15 Jan 2026
29 Jan 2026
15 Jan 2026
Earthwork in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sand stone) including removing, spreading or stacking the spoils within a lead of 75m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.
Earthwork in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(a)With earth obtained from excavation of foundation.
Earth work in filling in compound, tank, low land, ditches etc. with good earth, in layers not exceeding 150 mm. including breaking clods and consolidating the same by ramming and dressing complete. (Payment will be made on profile measurement before and after the work) and after the work (ii) With carried earth arranged by the contractor within a radius exceeding 3 km. but not exceeding 5 km. including the cost of carried earth.
(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) (B) Do - by fine sand
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
(I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) [Pakur Variety] (a) 1:3:6 proportion
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth
Ordinary Cement concrete (mix1:1.5:3) with graded stone chips ( 20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(i) Pakur Variety GROUND FLOOR
Hire and labour charges for shuttering with centering and necessary staging up to 4m using approved stout prop sand thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion ofworks (up to roof of ground floor) (f) 25 mm to 30 mm shuttering without staging in foundation (When the height of a particular floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht.shall be allowed under 12 (e) for every 4 m or part thereof) (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In- Charge.
(c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binder set cinitial straightening and removal of loose rust (if necessary ), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation, basement and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel (JSW/Shyam/SRMB/Electro steel)Groung Floor
Brick work with 1st class bricks in cement mortar (1:6) in ground floor (b) In superstructure,Ground floor
Labour for Chipping of concrete surface before taking up Plastering work.
Plaster (to wall , floor, ceiling etc.) with sand and cement mortar including rounding of for chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/stagingwhere necessary (Ground floor). [Excluding cost of chipping over concrete surface] (iii) With 1:6 cement mortar (b) 20 mm thick plaster
(ii) 15 mm thick plaster (1:6)
(c) 10 mm thick plaster (Bottom of Slab)
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75kg/sq.m all complete including all materials and labour.In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement (iii) 35 mm. thick
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white
Supplying maruti lock (100mm) i) For windows
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. i) 4mm thick clear glass.
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials For door
Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. (b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only]
(viii) M.S. integrated grill as per approved design integrated with steel window or ventilator, joints continuously welded with M.S. flats and bars 17 kg per sqm.
(a) M.S . Or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screw sand lugs in ground floor.(i) Grill weighing above 10Kg./sq.mtr and up to 16 Kg./sq. mtr. (i) Grill weighing above 10Kg./sq.mtr and up to 16 Kg./sq. mtr.
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface :With other than hi-gloss of approved quality- (iv) Two coats (white in shade)
(b) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Externel wall in Ground Floor.
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as equired. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer In Ground floor (Two Coat) a) Normal Acrylic Emulsion
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if ecessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. A) UPVC Pipes (ii) 110 mm. Dia.
Supplying, fitting & fixing of approved white board for class room purpose
Supplying & Installation of 12 nos wooden combined desk size 6'x 15" x 12" (WBSIDC code WFG 034) with specied colour including 18% GST, 1% Cess
Supplying & Installation of 1 no wooden Tabel size 3'x 2' x 2'6" and 1 no wooden armless chair with specied colour including 12% GST, 1% Cess
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECCAverage run 6 mtr
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.
Fixing only lamp
Fixing only single/twin florescent light fitting completewith allaccessories Directly on wall/ceiling with HW block and suitablesize MS fastener, Ceiling plate, nipples etc. as required
Fixing only ceiling fan complete with blades, canopy, fork,rubberbush etc. incl. S&F connecting wire for down rod upto 30 cm incl.painting the rod with approved paint and making necessaryconnection as required by 2x1.5 sqmm flexible copper wire Extra for supplying additional wire for down rod & painting the rod exceeding 30 cm by 2x1.5 sqmm flexible copper wire.
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existingModular GI switch board with top cover plate incl. makingnecy. connections etc.
Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box.
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish.On board
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy.connection as required & main line
"Do"2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
Supplying and fixing polythene pipe complete with fittingsasnecy. under ceiling/beam, bound with 22 SWG GI binding wireincl. supplying and drawing 1x18 SWG GI Wire as fish wireinside the pipes and fittings and providing 50 mm dia disc ofMS sheet (20 SWG) having colour paint at one face fastenedat the load point end of the polythene pipe with fish wire(synchronizing with roof/beam casting work of buildingconstruction) b) 19mm dia 3mm thick Polythene Pipe
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe
Supplying and fixing Sheet steel Main Switches on flat iron frame on wall 30/32 A 240V DP with fuse on L&N
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing 2+4 way Standard/ Havells
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection 40 A Standard/ Havells
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection 6-32 A
Supply only Trim Linea is a PC batten. Compact appearance, simple and versatile in nature makes it as long lasting, efficient solution for offices and other commercial spaces. Efficacy : 100 lumen/watt LCTLN-20-CDL Make- Havells/ Philips/ Crompton
Supply only LED ADORE 9 W B22 WW 3 STAR LAMP Make- Havells/ Philips/ Crompton
Supply and delivery of Ceilling fan 48” Sweep Make- Crompton Greaves / USHA Model- Striker Color- WH/ BR
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch with indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.98 MB
Tendernotice_2.pdf
PDF • 1.75 MB
BOQ_2416401.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid