| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.1 LAccepted-AOC | ₹25.1 L Quoted ₹25.9 L | L1 | Accepted-AOC Accepted due to lowest rate quoted. |
| 2 | L2₹26.3 L+₹47,778.30 (1.85%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | ₹26.3 L+₹47,778.30 (1.85%) | L2 | Rejected-Finance Rejected due to highest rate quoted |
| 3 | Rejected-Technical 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | - | - | Rejected-Technical Intent MOU not uploaded by the bidder. |
| 4 | Rejected-Technical | - | - | Rejected-Technical Intent MOU not uploaded by the bidder. |
| 5 | Rejected-Technical N A | NEW DELHI | DELHI | 110001 | - | - | Rejected-Technical Intent MOU not uploaded by the bidder. |
Tender Value
₹31.5 L
EMD Value
₹63,000
Closing Date
18 Oct 2024, 6:00 pmClosed
GE (AF) GURGAON
GE (AF) GURGAON
REPAIR/MAINTENANCEOF LT FEEDER PILLAR LT PANELS EARTHINGS LT CABLES APFC PANELS ALONGWITH CONNECTED ITEMS AND COMPREHENSIVE MAINT OF UPS INSTALLED AT NCN AND IMAC AT NTS GURGAON UNDER GE (AF) GURGAON
2024_MES_675641_1
GE/GUR-/NIT-28/2024-25
Open Tender
Civil Works
Item Rate
330 days
GE (AF) GURGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) GURGAON
₹63,000
10 Dec 2024
20 Sept 2024
21 Oct 2024
20 Sept 2024
18 Oct 2024
4 Oct 2024
Amount
Excavation in trenches n exc 1.5 wide and n exc 1.5 m in depth for foundation etc or for laying cable etc n exc 10 Sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in including spreading, leveling, watering and well ramming in layers exc 25 cm thick complete all as specified and as directed.
Removal of excavated material/surplus soil to a distance n exc 50m and depositing where directed at a level n exc 50m above the starting point complete all as specified and as directed.
Supply and filling river sand in trenches including spreading for cushioning of LT UG cable complete all as specified and as dirceted. Note : Punned down thickness shall be measured and paid .
M&L for sub class ‘B’ bricks old size laid flat dry in trenches over cable, across the direction of cable complete all as specified and as directed.
Supply, laying and testing in replacement of cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 3.5 core x 185 Sq mm. complete all as directed. Note : Provision of suitable double crimpped lugs and glands shall deemed to be included in quoted rates.
All as per item No 6 described here in before but 3.5 core 120 sqmm
All as per item No 6 described here in before but 3.5 core 95 sqmm
All as per item No 6 described here in before but 3.5 core 70 sqmm
All as per item No 6 described here in before but 3.5 core 50 sqmm
All as per item No 6 described here in before but 3.5 core 35 sqmm
All as per item No 6 described here in before but 4 core 25 sqmm
All as per item No 6 described here in before but 4 core 16 sqmm
Supply and fix in replacement of aluminium busbar of LT panel of rating upto 630 Amps complete all as specified and as directed. Note- 1 RM consists of R,Y,B and N)
M&L for repairs of ACB (air circuit breaker) draw out type of rating 1250 Amps 4 pole, 50 KA, O/L, S/C, micro processor based release and cassette mounted horizontal draw out type fully interlocked cassette door automatic safety shutters, mechanical on and off indicators, service/test/isolated position with position indicators, provision of castell lock, with O/L, S/C with 3 CT's of standard ratings 4 blocks of 6 way sliding type LT disconnectors, error prevention plug, racking handle, safety shutters and painted with finished light grey shade as per IS:631 and as per IS 13947-2-1993 inclusive suitable length of bus bars complete all as specified and as directed. (All repair cost and replacable items cost includes in the quoted rate and US item is of contrator's property and rate quoted included in this))
All as per item No 8.00 described here in before but 800 Amps.
S&F in replacemnt of MCCB with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning complete all as specified and as directed as per existing model/make of the following sizes:-
100 Amps 4 Pole breaking capasity 35/36 KA .
160 Amps 4 Pole breaking capasity 35/36 KA .
200 Amps 4 Pole breaking capasity 36 KA .
200 Amps 3 Pole breaking capasity 36 KA .
250 Amps 4 Pole breaking capasity 36 KA .
250 Amps 3 Pole breaking capasity 36 KA .
400 Amps 4 Pole breaking capasity 36 KA .
630 Amps 4 Pole breaking capasity 50 KA .
M & L in replacement for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including using galvanised iron strip 32×6mm as earthing strip by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth plate surrounded by packed layer of char coal dust and common salt, 15cm thick all around bottom and top and watering pipe 20mm bore of GI light grade with funnel, wire mesh and 40 mm dia GI protection pipe medium grade all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point, main switch board and testing on completion including excavation, earth work concrete pit with 80mm thick RCC cover in RCC 1:2:4 type B-1 duly reinforced with MS bars 8mm dia @ 150C/C both ways and pit chamber in PCC 1:2:4 type B-1 with 2 Nos suitable lifting handles of 12mm MS bar complete all as specified and as directed.
Supply and lay in trenches GI strip 25 mm x 4 mm galvanised iron strip for earth continuity earthing complete all as specified and as directed.
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed.
M&L for defect rectification high tension or LT cable of any size and laid in trenches by fault locating machine comprising of surge generator pulse,ECHO fault locator with high frequency distance calculator etc and exposing the cable fault,removal of deteriated portion of cable , treating of cable and making the same ready for jointing work complete all as specified and as directed. Note : (i) Cost of necessary excavation and earth work (by hydra machine or manual which suits), labour,fixing charges & T&P including removing of grass/shrubs nearby the fault location shall be deemed to include in quoted rates. (ii) This item also includes charges for exacavation in concrete/pitched road (by hydra or any means) in case fault occurs in the cable below the road or hard concrete area and making good the same as orginal finish.
M&L in repair for heat shrinkable jointing kit including suitable size of connector complete all as per directed by Engr-in-charge. Note : Cost of necessary excavation and earth work (by hydra machine or manual which suits), labour, Jointing kit complete, fixing charges & T&P including removing of grass/shrubs nearby the fault location shall be deemed to include in quoted rates) complete all as specified and as directed for the following sizes :- Note- This item also includes charges for exacavation in concrete/pitched road (by hydra) in case fault occurs in the cable below the road.
(a) XLPE Cable of size 16 sqmm to 50 Sqmm x 3.5/4 core .
(b) XLPE Cable of size 70 sqmm to 120 Sqmm x 3.5/4 core .
(c) XLPE Cable of size 185 sqmm to 240 Sqmm x 3.5/4 core .
(d) XLPE Cable of size 300 sqmm to 400Sqmm x 3.5 core .
Dismantling concrete poles any size complete and setting aside complete all as specified and as directed. Note: "Hydra Crane Charges deemed to be included in the quoted rates".
Supplying, transporting to site erecting and fixing in truly vertical position in replacemnt of steel tubular swaged and welded pole type 410SP-31(9 Mtr long) Swan neck complete with CI base plate,taper plug,bolts,nuts,and screws etc duly painted internally and externally with metal oxide anti corrosive paint before errection and painting with two coats aluminium paint after erection complete all as cofirming to IS 2713 (part-1 to 111) complete all as specified and as directed. Note : Necessary earth work and concrete shall be measured and paid separately under relevant item of sch A.
M&L for Foundation for Tubular swaged pole type including excavation , getting out, pole foundation with PCC (1:4:8) type D 2 (using with 40 mm graded crushed stone aggregate). Coping of pole with PCC (11:3:6) type C ( using with 20 mm graded stone agregate) and removing surplus soil to a distance n.exc 50 m and making good surface complete all as specified and as directed .
S&F in replacement LT volt meter (0-500) digital square flush type of size 96x96 mm including necessary addition/ alternation of panel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder including taking out of unserviceable Volt meter complete all as specified and as directed.
S&F in replacement 1100 Volts grade LT Ammeter (0 - 300 A) digital square flush type & CT type with CT's including necessary addition/ alteration of panel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder taking out of unserviceable Ammeter complete all as specified and as directed.
S&F in replacement 1100 Volts grade LT Ammeter (0 - 500 A) digital square flush type & CT type with CT's including necessary addition/ alteration of panel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder taking out of unserviceable Ammeter complete all as specified and as directed.
Taking down old UNSV fidder pillar and Supply, fixing, testing and commissioning in replacement of feeder pillar panel single door floor mounted and wall/pole mounted outdoor type, as per IP-55 grade, made out of MS sheet 3.15 mm thick of size 540x525x200mm with aluminium bus bar 250 Amps, 4 strip (3 phase) complete drilled, insulated with colour coded insulation tape, mounted on insulators etc with RYB indicator, panel should be dust proof, vermin proof, powder coated , locking should be screw type, mechanical type, inter locking with 150 Amps 25 KA MCCB four pole for incomer cable, should have danger notice for 415 volts, AC, mounted on 50x50x6 mm angle iron frame having minimum 2 feet ground clearance duly embedded in and including PCC block (1:2:4) complete including termination of all incoming and outgoing cables with suitable size thimbles/lugs and glands etc and providing fixing arrangements including earthing lead fixing arrangement, complete all as specified and as directed. Note :- Installation, testing, commissioning and connecting of incoming and outgoing cable connection LT feeder pillar panel shall included in rates quoted.
S&F vertical type load line distribution board, double door, 4 way AC, 3 phase 415 volts, TPN bus bar 200 Amps rating and earth bus and din rail including 01 No. MCCB 3/4 pole 415 volts, 50 Hz, 100Amps 16 KA breaking capacity as incomer complete all as specified and as directed.
S&F in replacement of MCCB 4 pole, 415 volts, adjustable type 63 Amps with breaking capacity 16 KA and connecting testing with MCCB complete all as specified and as directed.
Supply and fix in replacement of MCB SP 6-32 Amps 230 volts 'B' series complete all as specified and as directed.
Supply and fix in replacement of MCB SPN 40-63 Amps 230 volts 'B' series complete all as specified and as directed.
Supply and fix in replacement of unservicable submain wiring with unsheathed multi-stranded FR Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 6 Sqmm single core HR Grade and one run of 6 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB complete all as specified and as directed.Note :- (i) Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete.Note (ii): Rates shall deemed to be included for taking down for chases of conduit, sunking for boxes cutting and making holes in wall/floor for passing in or through conduit.
Supply & fix in replacement of SPN enclosure with two pin and earth plug and socket complete with on SP MCB 20 Amps complete all as specified and as directed.
Supply & fix in replacement of SPN enclosure with two pin and earth plug and socket complete with one SPN MCB 32 Amps complete all as specified and as directed.
M&L for painting of steel tubular pole including cable protection pipe and all iron parts of 9 mtr long pole complete with 2 coats of aluminium paint after cleaning all rust and dust and preparing surface with wire brush and including strips (30 cm wide each)of white and red colour of synthetic enamel paint up to the height of 1.5 mtr from the bottom of the pole and numbering of poles complete all as specified and as directed.
M&L for preparation of old painted surface of electric RCC pole by removing all dirt, dust etc and apply approved colour one coat of syhnthetic enemal paint upto 1.5 mtr height (Five layer 30 cm Blue and 30 cm White one over another) and one coat of synthetic enamel paint on steel surface such as cross arm including writing of identification No , etc complete all as specified and as directed.
M&L for Spray painting to LT panel board any size with synthetic enamel high glow paint Ist grade including preparation/cleaning of steel surfaces by wire brushing, grinding etc. complete all as specified and as directed.
Supply and fixing in replacement polycarbonate Kiosks box suitable for 3 phase 415 volts AC Supply with 4 Nos AI bus bar weather proof street light junction box of size 300 x 200 x 105mm including MCB SP 6 Amps and connecting terminals 4 way and fixing with street light poles using necessary MS clamps, nuts, bolts washers, lugs for incoming and out going cables, gland for cable etc of suitable size complete all as specified and as directed. Note : The rates quoted shall inclusive of provision and fixing of suitable lugs and glands for cable connection.
Material and labour for PVC flat twin core 2.5 sq mm aluminium wire 1100 volt grade laid in 20 mm dia medium grade rigid PVC conduit (and fixing brackets on PCC pole) from Loop-in-loop out junction box to light fitting terminal complete all as specified and as directed.Note :- PVC conduit shall be clamped properly with suitable clamps and no extra payment shall be done on this account.
M&L for replacement of rusted interal structure of LT panel of Size upto 7'5''X7'2''X3'2'' Shall be dust and vermin proof, protection class (IP-42) and made of 3.00 mm thick CRCA SHEET complete all as specified and as directed.
Supply only aluminium thimble heavy duty ISI mark suitable for 25 sqmm 3.5 cable complete all as specified and as directed.
All as item 48 above but 35 x 3.5 sqmm cable .
All as item 48 above but 50 x 3.5 sqmm cable .
All as item 48 above but 70 x 3.5 sqmm cable .
All as item 48 above but 95 x 3.5 sqmm cable .
All as item 48 above but 120 x 3.5 sqmm cable .
All as item 48 above but 150 x 3.5 sqmm cable .
All as item 48 above but 185 x 3.5 sqmm cable .
All as item 48 above but 240 x 3.5 sqmm cable .
M&L for dismantling of upper cover of servo Voltage stabilizer of capacity 400 KVA after disconnecting electrical connection for overall servicing , cleaning of dust and replacement of complete old wiring with FRLS PVC insulated copper conductor of existing size in proper layout and tight with tie including replacement of any unserviceable parts i.e main transformers and dimmerstat (Variac) three phase , electronic card, servo moter , carbon bush or any other parts complete including testing, complete all as specified and as directed. Note : 1. Replacement of any unserviceable parts will be measured and paid separatly under relevant items except replacement of old wiring which are deemed to be included in the quoted rate. 2. Any defects occured in repair portion done by contractor during defect liability period will be maintained by the contractor and no extra payment to be made by the derpartment for such repair/ replacement.
Supply and fix Main Transformer of suitable size upto the capacity of upto 400 KVA stabilizer complete all as specified and as directed.
Supply and fix Carbon bush of suitable size upto the capacity of upto 400 KVA stabilizer complete all as specified and as directed.
Supply and fix indicators of RYB of suitable size upto the capacity of upto 400 KVA voltage stabilizer complete all as specified and as directed.
Supply and fix Synthetic insulating mat of size 2Mx1Mx10mm thick ISI marked complete all as specified and as directed.
Supply and fix Synthetic insulating mat of size 2Mx1Mx12mm thick ISI marked complete all as specified and as directed.
Replacement of control PCB and motor drive complete all as specified and as directed.
Supply only Dimmer as per site requirement alongwith limit switches complete all as specified and as directed.
Supply & Filling /pouring of up to the appropriate level Transformer oil of low viscosity confirming to IS-335 (latest) having dielectric strength not less than 60 KV with 2.5 mm gap complete all as specified and as directed .
M&L for Comprehensive, preventive and periodical maintenance of total 4 Nos UPS of capacity (60 KVA-02 Nos, Sr No. 201306NR0525, 201306NR0526, 200 KVA-02 Nos Sr No. 201311NR0591, 201302NR0420) make/model Liebert. NXr/VERTIV Energy Private Limited, by Cleaning up of Unit, Visual Inspection to check any deformation, Checking and Adjustment (If needed) of Power parameters like input. Output, DC voltage & Current, Checking and adjustment of control parameters on different PCBs, Tightning of all connection, Functional Checking up of Rectifier section, Functional Checking up of Inverter section, Functional Checking up of Static Switch Section, With user approval, perform operational test of the system including unit transfer and battery discharge, Attending to complain breakdown calls whenever required, UPS failing to transfer to battery mode in the event of incoming power failure, Battery Breaker tripping due to battery failure, Battery Failure, UPS unadie to transfer load on to the parallel UPS (Redundancy Fallure), UPS tripping on High temperature condition, Control Card, major components failure such as IGBT's, SCR's & Wire wound Components within the UPS, Module Failure, Wire Harness damage, Reporting the healthiness of the plant and suggesting improvements if any, complete all as specified and as directed. Defective parts discovered during maintenance repaired or replaced by new or as new parts. Spares replaced will be either of the same make or equivalent. Old/U/sParts removed shall be property of contractor. Batteries, Switch gears & wound components is not part of Comprehensive AMC Contract
Note for item No 46.00 (1) The tenderer shall have to replace the U/s material with OEM material only. The cost of replaced major/minor spare parts included in comprehensive maintenance of contract. Old material will be contractor property. (ii) In case any accident occur of any Indi like Mechanic/Helpers/users during maintenance/operation of above mentioned Airconditioner/unit, contractor is liable to pay compensation to the Indl as decided by the competent authority. Principal Employer will not be responsible for the same. (iii) If complaint is not attended by contractor with in five hour the penality of Rs 1000/per hour to be imposed and amount of penality will be deducted from RAR. (iv) The cost of transportation (to and fro) for all kind of necessary equipment/ T&P shall be arranged/brought by contractor to complete the job at site, stationary for maintenance of record. no extra cost shall be paid to the contractor to this effect. (v) Complaint shall be lodged telephonically so contractor to specify the telephone no of contractor representative who will attned the complaint round the clock. After attending the complaint contractor will obtain the signature from rep of User/AGE/GE every day as a token of complaint attended. (vi) The Schedule 'A' consists of Comprehensive, preventive and periodical maintenance of 4 Nos UPS of capacity (60 KVA-02 Nos Sr No. 201311NR0591, 201302NR0420 and 200 KVA-02 Nos Sr No. 201311NR0591, 201302NR0420) make/model Liebert.NXr/VERTIV Energy Private Limited, installed at IMAC station Under GE (AF) Gurgaon. The work under this contract shall be carried out through authorized dealer/ Technician of M/s VERTIV Energy Private Limited only all as described in schedule 'A' special conditions, particular specification, MES SSR and as directed.
Comprehensive and preventive maintenance The work under above item Ser No 46 shall be carried out through OEM of M/6 VERTIV Energy PVT LTD only all as described in schedule 'A' special conditions, particular specification, MES SSR and as directed by GE/Engineer-in-charge Comprehensive and preventive maintenance shall be carried out by contractor through trained Engineer of M/s VERTIV Ltd only. The MOU will be signed by both the parties (i.e) contractor and OEM on a non judicial stamped paper of Rs 100/- duly notarized. All the Bidders shall upload a letter of 'Intent of MOU' through OEM ie M/s VERTIV Energy Pvt LTD in Cover-1 regarding the willingness of MoU to be done between Bidder & OEM post acceptance of the Tender. The letter of declaration will AS PER CONTRACT Documents. Failing which Bidders shall be rejected for bid opening of Cover-II.The successful L1 Bidder shall submit MOU as per format within 07 days from date of issue of Work Order No 1, failing which late charges @0.5% OF CA amount per week from date of acceptance shall be imposed on contractor. The contract shall be liable to be cancelled without any notice under condition 54 of IAFW 2249 if MoU not submitted by L1 bidder within 5 week of acceptance. Un occassion to this Performance Security @ 5% shall be forfeited by Department and work may be get executed under other means. Any Condonation of delay will be adjudicated by the Accepting Officer only. No extension will be granted on the part of OEM causing delay in signing the MoU with L1 bidder.
M&L for Comprehensive, preventive and periodical maintenance of total 2 Nos UPS of capacity (60 KVA- 01 Nos, Sr No. 9190501007, 250 KVA- 01 Nos Sr No. 9190800391, make/model: DPA U SCALE /ABB, By inspecting the all units and carry out quarterly as a part of preventive maintenance, with relevant PM checklist.by Cleaning up of Unit, Visual Inspection to check any deformation, Checking and Adjustment (If needed) of Power parameters like input. Output, DC voltage & Current, Checking and Adjustment of Control parameters on different PCBs,Tightness of all connection,Functional Checking up of Rectifier section, Functional Checking up of Inverter section, Functional Checking up of Static Switch Section, With user approval, perform operational test of the system including unit transfer and battery discharge, Attending to complain breakdown calls whenever required, UPS failing to transfer to battery mode in the event of incoming power failure, Battery Breaker tripping due to battery failure, Battery Failure, UPS unable to transfer load on to the parallel UPS (Redundancy Failure), UPS tripping on High temperature conditions, Control Card, major components failure such as IGBT’s, SCR’s & Wire wound Components within the UPS, Module Failure, Wire Harness damage, Reporting the healthiness of the plant and suggesting improvements if any, complete all as specified and as directed. Defective parts discovered during maintenance repaired or replaced by new or as new parts. Spares replaced will be either of the same make or equivalent. Old/U/sParts removed shall be property of contractor. Batteries bank replacement is not part of Comprehensive AMC Contract. Note : In this contract, these work's will start after March 2025 as per requirement of the site.
M&L for Comprehensive, preventive and periodical maintenance of total 2 Nos UPS of capacity (10 KVA- 02 Nos, Sr No. ZOV18C00298WT & Sr No. ZOV18600305WT ,Make- Delta, Model :GES103HH, By inspecting the all units and carry out quarterly as a part of preventive maintenance, with relevant PM checklist.by Cleaning up of Unit, Visual Inspection to check any deformation, Checking and Adjustment (If needed) of Power parameters like input. Output, DC voltage & Current, Checking and Adjustment of Control parameters on different PCBs,Tightness of all connection,Functional Checking up of Rectifier section, Functional Checking up of Inverter section, Functional Checking up of Static Switch Section, With user approval, perform operational test of the system including unit transfer and battery discharge, Attending to complain breakdown calls whenever required, UPS failing to transfer to battery mode in the event of incoming power failure, Battery Breaker tripping due to battery failure, Battery Failure, UPS unable to transfer load on to the parallel UPS (Redundancy Failure), UPS tripping on High temperature conditions, Control Card, major components failure such as IGBT’s, SCR’s & Wire wound Components within the UPS, Module Failure, Wire Harness damage, Reporting the healthiness of the plant and suggesting improvements if any, complete all as specified and as directed. Defective parts discovered during maintenance repaired or replaced by new or as new parts. Spares replaced will be either of the same make or equivalent. Old/U/sParts removed shall be property of contractor. Batteries bank replacement is not part of Comprehensive AMC Contract. Note : In this contract, these work's will start after March 2025 as per requirement of the site.
M&L for Comprehensive, preventive and periodically maintenance of the Main LT Panel: Capacity - 2 No. 1250 A 4P, 50kA (Ics=Icu=Icw for 1s) EDO ACB LSIG with microprocessor based built-in over current, earth fault, short circuit releases, auxiliary contacts, status indication on release, release healthiness indication & ON-OFF-TRIP indication for each and necessary protection CT's of suitable ratings. (For transformer ), 2 No. 1250 A 4P, 50kA (Ics=Icu=Icw for 1s) EDO ACB LSIG with microprocessor based built-in over current, earth fault, short circuit releases, auxiliary contacts, status indication on release, release healthiness indication & ON-OFF-TRIP indication for each and necessary protection CT's of suitable ratings. (For DG )Bus coupler- 1 No 1250 FP ACB 50 kA . The Interlocking in the main incoming ACB's to be done as per the DG AMF Panel Load management & Load sharing is to be done through DG controller & controller of DG shall be interlocked through DG AMF Panel. First DG will act as master & second DG will act as slave ( Both the DG shall be programmed such that both could run for no of hours ) Along with PLC Micro 830 for the Auto operation.Outgoings:- 2 Nos 800 A ACB - 50 kA & , 5 Nos. 100 A FP MCCB (16 kA/1 sec), 4 Nos. 63 A FP MCCB (16 kA/1 sec) , 2 No. 40 A FP MCCB (16 kA/1 sec) , 1 No. 25 A FP MCCB (16 kA/1 sec) , 1 No. 500 A FP MCCB (16 kA/1 sec) by carry out preventive maintenance of the complete panel on quarterly basis, checking the all control wiring, breaker, relay's and other related accessories of the panel like load manager, control MCB's, contactor's ..etc. Attending to all breakdown complaints whenever required, carry out external cleaning complete all as specified and as directed. Note : In this contract, these work's will start after March 2025 as per requirement of the site.
M&L for Comprehensive, preventive and periodically maintenance of the APFC PANEL : 195 Kvar - Main I/C- 1 Nos.500A TP MCCB 16 kA (O/C, S/C, E/F). Terminals suitable to receive suitable aluminum armored cable connection on one side and Busbar connection on the other side. 1 Nos contactor- 400 A, AC6b, 3pole, relay- 3 phase outgoing:- 2 No. 125 A TP MCCB, 16kA (Ics=Icu), along with ON-OFF indication lamps & push button switch. 3 pole capacitor grade contactor suitable for automatic switching of 50 kVAR capacitor bank, 1 No. 80 A TP MCCB, 16kA (Ics=Icu), along with ON-OFF indication lamps & push button switch, 3 pole capacitor grade contactor suitable for automatic switching of 25 kVAR capacitor bank, 3 pole capacitor grade contactor suitable for automatic switching of 10 kVAR capacitor bank, 10 kVAR hermetically sealed metallized polypropylene capacitor units complete with fuse protection, discharge resistors, interconnections etc., 6 Nos. 16 A TP MCCB, 16kA (Ics=Icu), along with ON-OFF indication lamps & push button switch. 5 kVAR hermetically sealed metallized polypropylene capacitor units complete with fuse protection, discharge resistors, interconnections etc. complete as required. 1 No. 12-step APFCR and allied control wiring with in-built power factor meter. By inspecting the allsystem and carry out quarterly as a part of preventive maintenance, with relevant PM checklist.checking the all control wiring, breaker, relay's and other related accessories of the panel like load manager, control MCB's, contactor's ..etc. Attending to all breakdown complaints whenever required, carry out external cleaning, complete all as specified and as directed. Note : In this contract, these work's will start after March 2025 as per requirement of the site.
Note for item no:47 to 50 (i) The tenderer shall have to replace all the U/s material with OEM material only. The cost of replacement of minor/major spare parts will not be paid seperatly. Old material will be the poperty of contractor and credit included in the rate quoted. (ii) In case any accident occur of any Indl like Mechanic/Helpers/users during maintenance/operation of above mentioned Airconditioner/unit, contractor is liable to pay compensation to the Indl as decided by the competent authority. Principal Employer will not be responsible for the same. (iii) If complaint is not attended by contractor with in five hour the penality of Rs 1000/ per hour to be imposed and amount of penality will be deducted from RAR. (iv) The cost of transportation (to and fro) for all kind of necessary equipment / T&P shall be arranged/brought by contractor to complete the job at site , stationary for maintenance of record, no extra cost shall be paid to the contractor to this effect. (v) Complaint shall be lodged by telephonically ,so contractor to specify the telephone no of his representative/ technician who will receive the complaint round the clock. After attending the complaint contractor will obtain the signature from rep of User/AGE/GE every day as a token of complaint attended. Note : In this contract, these work's will start after March 2025 as per requirement of the site.
Dismantling and taking down LED Street lights, High Mast lights, Dome/ Gate lights/ flood light fitting and bollards of any capacity, type or size for repair and replacement of worn out accessories and refixing on bracket on pole/wall after repair all as specified . Note- Any spare parts, LED, starter, tools, man power, driver etc for making serviceable is deemed to be included into quoted rate complete all as specified and as directed. Note:- Rent for hydra is included in rates quoted by the contractor.
Removing out of carbon particle/sulphate from 9/11 mtr street light pole junction box/light fitting/OH conductor incuding cleaning and refixing properly to make light functional complete all as specified and as directed. Note:- Rent for hydra is included in rates quoted by the contractor.
S&F in replacement of Energy saving environment friendly High mast Flood Light with innovative di cast aluminium IP 66 Flood light fitting with 120W LED as light source complete all as specified and as directed. Note: All fixing material is included in the unit rate.
S&F in replacement of Energy saving environment friendly High mast flood Light with innovative di cast aluminium IP 66 Flood light fitting with 100W LED as light source complete all as specified and as directed. Note: All fixing material is included in the unit rate.
Supply and fixed in replacement of integral post top ideal to lit up luminaires energy saving 40 watt LED lamp, with symmetrical light distribution system di-cast aluminium luminairie with high power LED as light source including LED lamp complete all as specified and as directed. Note: All fixing material is included in the unit rate.
Repair/Maintenance of high mast light of any size, oiling of motor of wench, repairing/renewal of burnt out cables, CG box, luminaire and made it functional complete all as specified and as directed. Note : (i) Components & parts to be replaced will be measured and paid separately. under relevant items of sch A (ii) Worn out components will be measured and paid separately under relevant items of schedule.
Supply only spare parts/ luminairies for high mast light are as under :-
(a) Copper conductor cable 10 sqmm x 4 core, 650 V/1100 V, un-armoured complete all as specified and as directed.
(b) M&Lin replacement of control panel for High Mast Light comprising of Timer, contactor, starter, up & down push button in sheet steel enclosure of 3.0mm thick CRCA sheet and fixed on PCC plateform complete all as specified and as directed.
(c) M&L for rewinding of winch motor of high mast light with super enamelled copper conductor and insulating material complete all as specified and as directed.
Supply and fix in replacemnt of automatic timer switch with switches ON/OFF the street lights base on lux level of natural light current rating 40 Amps, 220 Volts, 50 Hz. The sensor based timer should also have over voltage and low voltage trip with auto reset facility the sensor alongwith suitable power contactor, MCB and support terminals should be enclosed in pole/wall mountable enclosure made of rust proof electric shock proof termite proof and FR grade special moulding compounds confirming to IP 54. The contactor MCB and circuit wiring shall have enough capacity to take load of 12 KW equally distributed over 3 phase complete all as specified and as directed.
M&L in replacement for the main reflector is in glass with SS side reflector of motorised revolving search light complete all as specified and as directed.
M&L in replacement of unserviceable LED light - 300 W, beam range 400 to 700 meter, IP 66, High lumon LED ˃ 140 cm/w, PF ˃ 0.95 optical grade PMMA/PC lens reflector, working volt 100 V to 300 V complete all as specified and as directed.
M&L in replacemnt of a faulty parts of existing control panel of revolving search light as per below:
(A) Variable Frequency drive.
(b) Voltmeter with push button.
(c )Fuse set.
(d) LED indicator plate.
(e) Variable resistance pot.
(f) Empty Control panel box (without any inside parts).
Supply and fixing in replacement LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
M/S Anand Enterprises (BID ID -3136258)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .