| 1 | L1₹69.7 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST REASONABLE BIDDER | |
| 2 | L2₹76.3 L+₹4.4 L (6.19%)Rejected-Finance DIWANBADA MANEGAON POST OFFICE KHAMARIA JABALPUR 482005 M P | JABALPUR | MADHYA PRADESH | 482005 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹77.4 L+₹5.6 L (7.76%)Rejected-Finance B 87 SHAM NAGAR KHAYALA ROAD NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹77.9 L+₹6.1 L (8.43%)Rejected-Finance NO 403 BENGALI COLONY RANJHI JABALPUR MP 482001 | JABALPUR | JABALPUR | MADHYA PRADESH | 482001 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹1.1 Cr
EMD Value
₹1.9 L
Closing Date
16 Oct 2024, 6:00 pmClosed
CWE JABALPUR
HQ CWE JABALPUR OPPOSITE SUPPLY DEPOT SADAR 482001
Certain repair/rewiring/replacement of internal electrification of Offr,JCOs and ORs Md and OTM Accn including MAP qtrs and maint of winter appliances (unrestricted area) of COD under GE(East) Jabalpur
2024_MES_675595_1
82687/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
JABALPUR
AS PER NIT
7 documents required · 7 mandatory
₹1,000
Yes
GE EAST JABALPUR
₹1.9 L
Yes
10 Dec 2024
20 Sept 2024
18 Oct 2024
20 Sept 2024
16 Oct 2024
4 Oct 2024
20 Sept 2024 - 3 Oct 2024
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, holders, pendants, regulators, sockets etc complete all as specified as directed.
Taking down carefully any type of old unserviceable submain wiring with PVC/steel conduit surface / concealed or wooden battens etc complete all as specified & directed by Engineer-in-Charge.
Taking down carefully any type of DBs including MCCBs and MCBs for keeping the old materials into safe custody or for taking credit(credit for above items should be made as per condition seaparately) etc complete all as specified and directed.
Material & Labour for point wiring with three layer PVC Insulated 1.5 Sqmm multi-stranded copper conductor FRLSH cable 1100 Volts grade drawn into and including concealed PVC conduits, medium grade not less than 20mm( ISI marked) including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes/Modular metal flush box duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick plastic laminated white sheet cover for mounting normal/modular switches, sockets, fan regulators fixed with CP screws with cup wahsers and PVC insulated 1.5 Sqmm multi-stranded copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar 1:3 to match with the existing surfaces complete all as specified & directed by Engineer-in-charge for One light Point controlled by one switch. (Note:- (i) Cost for cutting chases and concealing the conduit pipe in existing wall is deemed to be included in quoted item rate. (ii) Conduit will be fixed on surface in ceiling.)
ditto as per item No. 04 but for one Fan Point controlled by one switch 5/6 Amp.
ditto as per item No. 04 but for one Bell Point controlled by one switch 5/6 Amp.
ditto as per item No. 04 but for one socket point 5 Amp controlled by one switch on same board.
ditto as per item No. 04 but for one socket point 5 Amp controlled by one switch on Independent board.
ditto as per item No. 04 but for one light point controlled by two way switch 5/6 Amp.
Description same all as per item No. 4 here in above but with 1100 Volts grade copper stranded conductor FRLSH cable of size 2.5 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 5/15 Amp on Independent board complete all as specified & directed by Engineer-in-Charge.
Material & Labour for point wiring with three layer PVC Insulated 1.5 Sqmm multi-stranded copper conductor FRLSH cable 1100 Volts grade drawn into existing PVC conduits medium grade not less than 20mm( ISI marked) including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes / Modular metal flush box duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3 mm thick plastic laminated white sheet cover for mounting normal/modular switches, sockets, fan regulators fixed with CP screws with cup wahsers and PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar 1:3 to match with the existing surfaces complete all as specified & directed by Engineer-in-charge for One light Point controlled by one switch.
ditto as per item No. 11 but for one Fan Point controlled by one switch 5/6 Amp.
ditto as per item No. 11 but for one Bell Point controlled by one switch 5/6 Amp.
ditto as per item No. 11 but for one socket point 5 Amp controlled by one switch on same board.
ditto as per item No. 11 but for one socket point 5 Amp controlled by one switch on Independent board.
ditto as per item No. 11 but for one light point controlled by two way switch 5/6 Amp.
Description same all as per item No. 11 here in above but with 1100 Volts grade copper stranded conductor FRLSH cable of size 2.5 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified & directed by Engineer-in-Charge.
M&L for point wiring with casing caping complete with FRLSH PVC insulated, unsheathed stranded copper conductor of nominal area 1.5 Sqmm, 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly in and sunken terminal boxes pressed MS/GI steel terminal boxes not less than 1.20 mm thick for mounting switch, socket etc including 3 mm thick Hylam brand sunmica laminated sheet cover or inner outer plates for modular switches with brass screw and cup washers with all accessories and making good to disturbed surface with cement mortar ratio of 1:3 and matching surface with existing white/colour wash, oil bound or cement base paint etc to match with existing surface complete all as specified and directed for one light/ Fan / Bell Point controlled by one switch.
ditto as per item No. 18 but for one socket point 5 Amp controlled by one switch 5/6 Amp on same board.
ditto as per item No. 18 but for one socket point 5 Amp controlled by one switch 5/6 Amp on Independent board.
ditto as per item No. 18 but for one light point controlled by two way switch.
Ditto all as per item No. 18 here in above but drawing in with casing caping or conduit on surface all as directed complete with point wiring using 2.5 Sqmm (Nominal area)triple layer FRLS PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet ,suitable for 6/16 amps on “independent board”.with 2.5 sqmm with one single run copper wire as continuous earth wire to common earth dolly complete.
M&L of Sub main wiring with two single core PVC Insulated cable two run of size 4 Sqmm multi-stranded copper conductor FRLS cable 1100 volts grade drawing in and including PVC conduit, concealed or on surface as per directed, medium grade not less than 20 mm dia with all conduit accessories and one run of 4.0 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire including making good disturbed surface to match existing complete all as specified & directed. Note : - Two run of 4 Sqmm & one run of 4.0 Sqmm cable shall be measured as one unit run.
M&L of Sub main wiring with two single core PVC Insulated cable two run of size 6.0 Sqmm multi-stranded copper conductor FRLS cable 1100 volts grade drawing in and including PVC conduit, concealed or on surface as per directed, medium grade not less than 25 mm dia with all conduit accessories and one run of 6.0 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire complete all as specified and directed. Note : - Two run of 6 Sqmm & one run of 6 Sqmm cable shall be measured as one unit run.
S&F call bell ding dong sound type suitable for AC 230 volt single pole complete all as specified & directed.
S&F switch bell push flush type suitable for 5 Amp 230 Volt of polycarbonate body complete all as specified & directed.
S&F switch piano flush type suitable for 5 Amp 230 Volt of polycarbonate body complete all as specified & directed.
S&F socket outlet 2 in 1, 5 Pin 5 Amp flush type of polycarbonate body complete all as specified & directed.
S&F Switch socket combination 5 in 1, 5 pin 5/6 Amps flush type universal of polycabonate body complete all as specified & directed.
S&F Switch socket combination 5 in 1, 5 pin 6/16 Amps flush type universal of polycabonate body complete all as specified & directed.
S &F Lamp holder, PVC/ polycarbonate type with back plate for angle holder all as per specified and directed.
S&F Ceiling rose surface type 60 x 30 mm three terminals of polycarbonate body complete all as specified & directed.
S&F Ceiling Fan regulator electronic type 280 Watt capacity of polycarbonate body ISI marked complete all as specified & directed.
S&F, in replacement, modular switch 6-10 Amps one module 230 volts AC as per existing model/make complete all as specified and as directed.
S&F, in replacement, modular switch 16 Amps one module 230 volts AC as per existing model/make complete all as specified and as directed
S&F, in replacement, modular socket, 6A -2/3 pin combined 2 module, 230 volts AC as per existing model/make complete all as specified and as directed.
S&F, in replacement, modular socket, 6/16A -2/3 pin combined 2 module, 230 volts AC as per existing model/make complete all as specified and as directed .
S&F, in replacement, modular bell push , 6 Amps, 1 mod complete all as specified and as directed.
S&F in replacement modular switch two way AC 230 volts 6 Amps , 1 module as per on existing switch board cpmplete all as specified and directed.
S&F in replacement modular fan regulator, 2 Module 4 step upto 180 W heavy duty 230 volts as per existing model/make complete all as specified and as directed.
S&F, in replacement, modular cover plate 2 module including screws and washers etc model/make as per existing one at site complete all as specified and as directed.
S&F, in replacement, modular cover plate 3 module including screws and washers etc model/make as per existing one at site complete all as specified and as directed.
S&F, in replacement, modular cover plate 4 module including screws and washers etc model/make as per existing one at site complete all as specified and as directed.
S&F, in replacement, modular cover plate 6 module including screws and washers etc model/make as per existing one at site complete all as specified and as directed.
S&F, in replacement, modular cover plate 8 module including screws and washers etc model/make as per existing one at site complete all as specified and as directed.
S&F, in replacement, modular cover plate 12 module including screws and washers etc model/make as per existing one at site complete all as specified and as directed.
S&F, in replacement, modular cover plate 16 module including screws and washers etc model/make as per existing one at site complete all as specified and as directed.
S & F, in replacement, Metal flush box 2 module complete all as specified and directed.
Ditto as per item No. 48 but 3 module complete all as specified and directed
Ditto as per item No. 48 but 4 module complete all as specified and directed
Ditto as per item No. 48 but 6 module complete all as specified and directed
Ditto as per item No. 48 but 8 module complete all as specified and directed
Ditto as per item No. 48 but 12 module complete all as specified and directed
Ditto as per item No. 48 but 16 module complete all as specified and directed
S&F, in replacement, 3 mm thick Hylam sheet of any size including brass screws and washers etc as required at site complete all as specified and as directed.
S&F in replacement of PVC insulated, unsheathed twin twisted copper conductor wire of nominal size 23/0.0076, 1100 volt grade, ISI marked, complete all as specified and directed.
Supply and Fixing Sheet metal enclosure for DBs when MCBs to be Used, 4 way, TP & N, double door type, 415 Volt, suitable for MCB incomer complete all as specified and directed.
Supply and Fixing Sheet metal enclosure for DBs when MCBs to be Used, 8 way, SP & N, double door type, 240 Volt. complete all as specified and directed. (Note : MCBs will be measured and paid for separately)
Supply and Fixing MCCB, four pole, 100 Amp, 415 Volt, of breaking capacity 16 KA complete all as directed.
Supply and fixing 415V, 10KA 'C' curve miniature circuit breaker (MCB), TPN, 63 Amps current carrying capacity in the DB complete with connection, testing and commissioning, complete all as specified and directed.
Supply and fixing 240V, 10KA 'C' curve miniature circuit breaker (MCB), SPN, 40 Amps current carrying capacity in the DB complete with connection, testing and commissioning, complete all as specified and directed.
Supply and fixing 240V, 10KA 'C' curve miniature circuit breaker (MCB), SP, 6-32 Amps current carrying capacity in the DB complete with connection, testing and commissioning, all as specified and directed.
Supply & Fixing in repair single pole and netural sheet metal enclosure with a two pin and earth plug and socket complete with 01 number single pole MCB 20 Amps complete all as specified & directed.
S & F for sheet metal enclosure MCB DB TPN 4 Way vertical type with 200 Amps rated bus bar 240 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed.
Taking down exhaust fan cable end, dismantling blades and removing fan and refix on old location complete all as specified and directed.
Supply & Fixing Smart bright Batten Series, LED luminaire using LEDs18/20 watt min 100 LM/watt, natural white(4000K)/ cool white (6500k), with diffuser which ensures uniform distribution and comfort batten series features latest LEDs and delivers consistent light output with wide voltage protection range, stable color start Extruded Aluminum housing, Energy efficient, Flicker free start Inbuilt driver unit Suitable for wall and ceiling mounting using brackets (supplied along with The Luminaire has been tested as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Secl), report has established conformity of the product(s) to the requirements of the Standard/Specification.
Supply and fix in repairs LED bulk head luminaires, 1x 6/7/9 watts (600-900 lumens) lamp with fittings, connecting cable PVC insulated and PVC sheathed copper flxible cable of size 16/ 0.20 mm with necessary fixing arrangments complete all as directed.
S & F LED Mirror light fitting 2 ft tubelight, 10 watt aluminum housing and integrated electronic driver complete with fixing arrangements on wall all as specified and directed.
S & F for LED luminaire cool day light/warm white as required of size 1'x 4' square LED panel 35/36 watts, 220V recessed type with high efficieny PMMA diffuser soft glare free light complete with drovers, holders, LED lamp suitable for roof ceilling, including connecting up with driver three core flexible copperr conductor cases of suitable size complete all as specefied and directed.
S&F LED light fitting square 2'x2', 35/36 watt, 3000 lumen, Cool white / Warm white , all as per direction, warm white along with fixture Surface / Recessed /Pendent mounting LED luminaries with diffuser channel Luminaires ers, connector block, etc . Complete with all accessories internally pre-wired and including round wood block, connecting up with three core flexible flexible copper conductor cable suitable size complete all as specified and directed by Engineer in charge.
Supply & fixing in repair LED light down lighter by recess or surface mounted 12 watt, warm white, circular/Square, 1200 lumen with fixing arrangemnts on ceiling complete all as specified & directed.
Supply & fix in replacement of LED Security Light Luminaire 35 watt with 2500 or more lumen warm white/cool day ligh with, surge protection device upto 4KV, IP65 or more, IK07 or more, potted driver suitable for 180 to 270 V, 50 Hz, light engine driver base.pole adapter, powder coated pressure die cast aluminium with heat resistant toughened glass with lens type,GI pipe 40 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos of pole/wall fitting clamps made out of MS flat , nuts and bolts and painting with two coats of aluminium paint. complete all as specified and as directed.
S&F in repairs LED Bulb 230V AC 9/10 watt warm/cool day light 6500K as per the direction/requirement at site complere all as specified and directed by Engineer-in -charge.
S&F decorative wall light fitting made up of Polycarbonate , Cylindrical shape or as per the sample required/obtained from the site and mounting arrangement to fix the lamp and all as directed by Engr-in-Charge with LED lamp 9 Watt complete with fixing arrangements on wall all as specified and directed.
M&L for taking down ceiling fan cable end, dismantling blades and removing fan and refix on old location complete all as specified and directed.
Preventive maintenance and checking of Ceiling / Exhaust / wall fan /air circulator / table fan / padestal fans of any size / type / make, checking the serviceability of safety pins, clamps, down rods, rubber bushes, nuts, bolts, canopies and electric connections etc. reconnecting / hanging in original position, reconnecting the electric cables and testing complete, all as directed. (Notes : (i) Spare parts shall be measured and paid seperately as supply only and rewinding of fan shall be measured and paid seperatly under relevant item here-in-below. (ii) The cleaning, servicing, oiling and lubricating of fans has to be carried at site itself and to be completed within one hour unless re-winding is required. (iii) The cost of transportation from site of work to workshop and back for rewinding is deemed to be included in the unit quoted rate, (iv) Rewinding shall be carried out in contractor's workshop and fan shall be re-fixed at site within 07 days after taking down from site.
M & L for rewinding of Ceiling fan of any sweep after dismantling with super enamelled bare insulated copper winding wires as per existing gauge and turn to achieve desired RPM including necessary insulating materials, insulating varnishing, cleaning, packing and reassembling and testing etc complete all as specified and as directed.
Material and labour for rewinding air circulator and padestrial fan with supper enamelled copper wire of existing size , gauge and turns after dismantling with super enamelled bare insulated copper winding wires including cleaning the slots properly, and testing complete all as directed.
Supply only ball bearing/bush set of two suitable for Ceiling / exhaust / pedestria l/ air circulator fan of any sweep complete all as per the existing specifications and as directed
Supply and fixing in repairs down rod of size 90 Cm length 15 mm bore GI pipe of light grade, suitable for Ceiling fan including cutting, making hohe etc. complete all as directed..
Supply and fixing in replacement of Unserviceable condenser ISI marked 2.5/3.15 mfd as per requirement and directed by the Engr-in-charge complete all as directed.
Supply only shackle and clamps including rubber bush, bolts, nuts, washer and split, canopies etc suitable for ceiling/exhaust fan of any sweep complete all as per the existing specifications and as directed
Supply only Metal blades set suitable for exhaust fan of size 225 to 450 mm sweep any make as per the site requirement complete all as per existing specification and as directed.
Supply only blades set suitable for ceiling fan of size 1200/1400 mm sweep any make as per the site requirement complete all as per existing specification and as directed.
Supply only plastic blades set suitable for bathroom exhaust fan of size upto 250mm sweep of any make complete all as per existing specification and as directed.
M & L for preparation of old painted surfaces of ceiling fan of any size/sweep/make, cleaning all dust etc and painting with one coat of synthetic enamel (1st grade quality white) paint (as directed colour)by spraying including filling cavities with filler and marking same MES No. with parmanent marker etc complete all as directed.
Supply and Fixing MCCB, four pole, 125 Amp, 415 Volt, of breaking capacity 16 KA complete all as directed.
Supply and Fixing MCCB, four pole, 63 Amp, 415 Volt, of breaking capacity 16 KA complete all as directed.
Supply and Fixing MCCB, four pole, 160 Amp, 415 Volt, of breaking capacity 36 KA complete all as directed.
Material & Labour for earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground (Earth pit not less than 2.25 m deep below the normal ground level with top edge of earth plate not less than 1.5 m below normal ground level) connected to galvanised earth wire 4 mm dia as earth wire or earthing lead by means of bolts, nuts, check nuts and washers of GI or steel complete as shown in Electrical Plate No. 3 of SSR-2009 (Part-I) including charcoal dust, common salt, 20mm bore GI medium grade watering pipe, MS Sheet funnel with wire mesh, including 15mm dia GI pipe light grade for protection of GI earth wire including PCC pit 1:2:4 type B-1 using 20mm graded crushed stone aggregate with angle iron 40X40X5mm frame 60mm thick RCC cover with 8mm # TMT bars @ 100 mm centre to centre both ways i.e. horizontal and vertical complete all as directed by Engineer-in-charge and testing for required value complete. Note:- If earth resistance of earthing is not found satisfactory it will be redone by the contractor without any extra cost to Govt.
S&F new geeration IP65 LED post top family energy sanving environmental friendly, long life aestheticall designed with symmetrical light distribution spunaluminium landscape luminaire with high power 25 Watt LED as light source, clear cover offers bright illumination with mounting arrangement complete all as specified and directed.
Taking down unserviciable / burnout geyser storage type of capacity 25 Liters and dismantling and deposite to MES store all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement indication lamp suitable for geysers of capacity upto 25/15 Liters of any description such as round/rectangular complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement geysers heating element round/tringle 2KW 240 Volt complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement syphon assembly complete with inter thermostate pipe etc and screw rubber packing for 25 Liters capacity as per existing sample complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement thermostate switch for geysers with temperature range 25 degree centigrade to 85 degree centigrade, 11" long, for Geyser of capacity 25/100 Ltr. complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement copper chromium plated CP connection 18" long with two brass adopter heavy duty ISI marked & connecting, for Geyser of capacity 25/35 Ltr. complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement safety valve/high pressure valve 15mm,as per side requirement for Geyser of capacity 25 Ltr complete all as specified and directed by Engineer-in-Charg. ISI marked.
Supply and fix in replacement metal plug top 2 pole and earth 240 volts complete all as specified and directed by Engineer-in-Charge .
Supply and fix in replacement of metal Socket 2 pole and earth 240 voltscomplete all as specified and directed by Engineer-in-Charge .
Supply and fix in replacement PVC connection with Brass adopter screwed at both ends 18" long heavy duty ISI Marked, complete all as specified and directed by Engineer-in-Charge
Supply & Fixing in replacment new wave 11.81" Alumimium Grip Connection pipe 12" premium quality for Geyser of capacity 25 Ltr.as specified and directed by Engineer-in-Charge.
Taking down geyser storage type of capacity 35/25 Liters and dismantling the complete accessories cleaning of inner copper tank outlet/inlet tubes, by cleaning material Vinegar .the inside of a geyser remove the corrosion and rusting from anode rod reassembling and refixing complete after repair, all as specified and directed by Engineer-in-Charge. Note : - (i) The accessories if replaced, shall be measured and paid for separately.
M & L for rewinding of Ceiling fan of any sweep after dismantling with super enamelled bare insulated copper winding wires as per existing gauge and turn to achieve desired RPM including necessary insulating materials, insulating varnishing, cleaning, packing and reassembling and testing etc complete all as specified and as directed.
M&L for taking down ceiling fan cable end, dismantling blades and removing fan and refix on old location complete all as specified and directed.
Schedule of credit amount of Rs 206366.00 to be deducted during AOC
C L BHATIA (BID ID -3129174)
New Era Engineers (BID ID -3134027)
J.P ENTERPRISES (BID ID -3133465)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .