Tender Value
₹39.9 Cr
EMD Value
₹5 L
Closing Date
24 Jul 2026, 5:00 pm
MR Yognarayan sahu(DFLT)
CE(Bridge)
CONSTRUCTION OF OVER PASS ON RING ROAD NO. 2 AT SONDONGARI CHOWK , RAIPUR.
194828
NIT NO: 679/TC/26-27
OPEN TENDER
WORKS
22 days
CE(Bridge)
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
18 documents required · 18 mandatory
Public Works Department (PWD)
WORKS
MR Yognarayan sahu(DFLT)
OPEN TENDER
LUMPSUM
OPEN TO ALL
CE(Bridge)
Bridge Circle, Raipur
Bridge Division Raipur
120
22
No
0
194828
24 Jul, 2026 5:00:00 PM IST
29 Jul, 2026 10:00:00 AM IST
3 Jul, 2026 7:00:00 PM IST
NIT NO: 679/TC/26-27
CONSTRUCTION OF OVER PASS ON RING ROAD NO. 2 AT SONDONGARI CHOWK , RAIPUR.
500000.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
399326000.00
2
28 Jul, 2026 5:00:00 PM IST
399326000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
20d 21h 38m
18 documents required · 12 mandatory · 6 optional
₹0
₹5 L
30 Jun 2026
30 Jun 2026
29 Jul 2026
3 Jul 2026
24 Jul 2026
3 Jul 2026
28 Jul 2026
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, multi strand wire in the existing surface/ concealed, FRLS PVC conduit / PVC casing caping as per specification and IS: 694 (2010) 3.11.3. 3 x 1.5 sq. mm
6 x 1.5 sq. mm
3 x 2.5 sq. mm
6 x 2.5 sq. mm
Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 6.28.9. 120 watt
Supplying of following 230/250 volts LED Flood light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Seperate housing for driver etc complete as per specification and P.A. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 6.29.5. 100watt
Providing and making interconnection in cubical panel between BBC and switchgears with following size copper strip of length upto 50cm as per specification (To be measured separately for each phase/ neutral). 7.18.1. 20x3mm (100 amps)
Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS powder coated sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as per specification. 7.19.1. Upto 300 mm deep
Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) copper (electric grade) bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification.7.21.1. 100 amp (20x3mm)
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 11.1.4. 3 pole MCCB, 100A, Adjustable Thermal - Magnetic Release, 25KA
Supplying and fixing SP MCB, 240 volts, 'C' curve, suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.11.2. 6 amps to 32 amps
Supplying and fixing DP MCB, 240 volts, 'D' curve, suitable for inductive/ motor load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.13.3. 40 amps
Supplying and fixing TP&N MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.16.5. 63 amps
Providing and fixing 3 pole, 415/500 volts following rating (AC-1 Duty) power contactor in existing starter/ cubical panel including, connections, testing and commissioning etc. as per specification. 10.13.4. 100 amps
Providing and fixing following rating current transformer in existing cubical panel including, connections, testing and commissioning etc. as per specification. 10.15.2.100/5 amps
Providing and fixing penal mounting 230 volt LED type indicating lamp in existing cubical panel including, connections, testing and commissioning etc. as per specification.
Providing and fixing penal mounting digital type ammeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification
Providing and fixing penal mounting 0-500 volt voltmeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification. 10.20.2. Digital type
For ammeter
Providing and fixing following Time switch (timer) in existing panel including connection, testing and commissioning as per specification. 10.22.2. Analoge type
Supplying and fixing Low voltage (class -II) surge protection device (SPD) TP&N 440 volts, in the existing MCB DB complete with connections, testing and commissioning etc. as per specification.
Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as per specification.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering, excavation and refilling the trench etc. as per specification.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)
Providing maintenance free earthing with following size GI pipe including making bore pit of minimum 150mm dia, providing and laying approved make Earthing Electrode of Pipe-in-Pipe technology as per IS 3043(R 2016) -1987 made of corrosion free G.I. Pipes having outer pipe of 80mm dia and inner pipe of 50mm dia and filling with specified qty highly conductive compound around pipe and above that with soft soil in bore pit complete and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. as per specification:12.19.1. With 3 metre long GI Pipes and 50 kg back filling compound.
Supplying and laying ISI marked double wall HDPE pipe (IS 14930 Part II) having corrugation on the outer wall and plan surface on inner wall in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 14.1.1. 63 mm outer dia and 50 mm Inner dia
Supplying and laying following size medium class G.I. pipe in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 14.3.1. 50 mm internal dia
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 15.3.22. 4 x 10 sq. mm.
4 x 16 sq. mm.
4 x 25 sq. mm.
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on surface/ existing cable tray with 25x3 mm M.S flat clamp and steel dash fastener/ G.I. bolts and nuts as per specification , IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 15.6.1. 3.5 x 50 sq. mm.
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. .15.23.24. 4 X 16 sq. mm (22 mm)
4 X 25 sq. mm (25 mm)
3½ X 50 sq. mm (32 mm)
Supply of hot dipped galvanized (in single dip to minimum 75 micron) octogonal pole made of 3mm thick steel grade E-350 sheet having window and flush cover with locking arrangement at suitable height from base for cable termination block, pole suitably reinforced with welded steel section at window cut section to make the strength of pole unaffected, with following minimum specifications with 4 way terminal connector including 4mm thick anchor plate, 4 nos 24mm dia foundation bolts of EN8 grade, and as per IS 2062 & BS EN: 10025. (designed for wind speed upto 180km/hr, IS: 875 Part 3) 19.8.1. 9 metre high, dia 155mm at bottom and 90mm at top, base plate size 260x260x16mm, foundation bolts 750mm long
Erection of GI octogonal/ tubular/conical pole on existing cement concrete foundation having grouted bolts and nuts, aligning in true vertical position as per specification. 19.11.7. 9 metre high
Designing and providing suitable RCC foundation in Cement Concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) for 3 mere to 12 metre high GI octagonal pole including steel reinforcement form work, embeding 2 nos 50mm dia PVC pipe for cable entry in each foundation, excavation disposal of surplus soil and curing etc. as per specification.
Providing and making suitable CC pole collar (muffing) in Cement Concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) of size 0.4 m dia and 0.4 m height from existing CC foundation.
Supplying and fixing of double over hang (Arm) 1500 MM (long)x50 mm dia decorative GI street light pole bracket made out of GI "A" Class pipe welded to 300 MM Long GI Pole canopy of suitable dia at angle of 102.50 Degree including having GI triangular stiffner and making arrangement for tightening the bracket with pole by providing suitable size heavy duty nuts and bolts in canopy including FRP Dome on existing pole etc. as per enclosed drawing and as per direction of engineer-in-charge.
Supplying erection testing and commissioning of hot dipped galvanised (single dip 86 micron) 16 metre High mast pole on existing RCC foundation with all accessories and equipments, detailed as below to withstand wind pressure upto 180km/hr and minimum following specifications: a) HM shaft made of not more than 2 sections of suitable lengths with telescopic stressfit joints between sections without any circumpherencial welding, sheet thickness 4mm top and bottom sections, nominal dia 460mm on bottom and 150 mm on top, base flange 25mm thick 670mm dia, PCD of foundation bolts 650mm. b) Double drum winch for lowering & raising of lantern carriage on high mast with operatable with power tool/ manual handle attachment with a torque limiting device for safe locking of carriage. c) Raising/lowering type lantern carriage designed to carry specified nos of luminaries, control gear box, junction box. d) Top pulley assemble with weather proof cover. e) 3 Nos suitable length and size stainless steel wire ropes (minimum 6mm dia and 7/19 construction) for lowering & raising of lantern carriage. f) Suitable size and length multicore flexible copper power trailing cable (minimum 3 core 4 sqmm) g) Hinged service door in base section h) Base plate earthing terminal. i) Suitable arrangement for supply distribution with termination of suitable size underground cable in high mast. j) Lightning conductor finial made of 25mm dia 300 mm long G.I. tube having single prong. k) Anchor plate of size 840x840x6mm, tem-plates 3mm thick, GI foundation bolts 8 Nos of 30 mm dia 850 mm long (EN 8 Grade) along with nuts washers etc. (RCC fooundation and luminaries will be paid separately)
Designing and providing suitable and approved size RCC foundation for 12-30 mere high mast including seel reinforcement form work, embeding 2 nos 50mm dia PVC pipe for cable entry in each foundation, excavation disposal of surplus soil and curing etc. as required including laying and fixing HM foundation bolts with tam plates but excluding the cost of foundation bolts with tam plates etc complete as per specification
Supplying and fixing of single over hang (Arm) 1500 MM (long)x50 mm dia decorative GI street light pole bracket made out of GI "A" Class pipe welded to 300 MM Long GI Pole canopy of suitable dia at angle of 102.50 Degree including having GI triangular stiffner and making arrangement for tightening the bracket with pole by providing suitable size heavy duty nuts and bolts in canopy including FRP Dome on existing pole etc. as per enclosed drawing and as per direction of engineer-in-charge.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.10 MB
1486582949948137493_177603_1869345262672871608_125835_Guidelines_to_Bidders_EPS_v1.pdf
NIT • 0.13 MB
1830522682504541343_194828_Form F.docx
NIT • 0.21 MB
5368357595411864985_194828_LIST OF APPROVED MATERIAL.doc
NIT • 0.06 MB
3866662593246774728_194828_Notice_F.doc
NIT • 0.11 MB
106830315980387862_194828_PQ.doc
NIT • 0.27 MB
7536074393195893379_194828_term and conditions.doc
NIT • 0.04 MB
4195089829501608611_194828_Drawing.zip
NIT • 2.81 MB
6621468227703176304_194828_BOQ street Light EM Work Sondongri.xls
BOQ • 0.05 MB
Download all tender documents and submit your bid