GE SEABIRD KARWAR
Military Engineer Services Garrison Engineer (Seabird) Sankrubag Post, Arga Karwar Karnataka - 581308
REPAIR AND MAINTENANCE OF INTERNAL ELECTRIFICATION, FITTINGS AND FIXTURES, INCLUDING MAINTENANCE OF SPLIT WINDOW ACs, WATER COOLERS REFRIGERATION UNITS AND ALLIED WORKS IN INHS PATANJALI AND MES OFFICE COMPLEX OF NAVAL BASE KARWAR
2026_MES_795801_1
8584/E8
Open Tender
Electrical and Maintenance Works
Item Rate
GE (SB) KARWAR
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
GE (SB) KARWAR
₹60,000
Yes
28 Oct 2026
28 Oct 2026
20 Nov 2026
28 Oct 2026
18 Nov 2026
11 Nov 2026
28 Oct 2026 - 4 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Rectifying defects in domestic fluorescent tube/CFL light fittings/wall security light fittings of any type and at any height, including ceiling roses and electric bells, by tightening loose connections and rectifying defects, testing, complete all as specified and directed. | 180 | Each | 1.25 | ₹225 |
| 2 | Opening switch mounting plate at normal height up to 1.5 m, rectifying defects in fittings/fixtures such as switches, bell push, fan regulator, sockets etc. by tightening loose connections, refixing switch plate and testing to make functional, complete all as specified and directed.
Note for Item No. 1.00 & 2.00: The unit rate quoted shall be deemed to include labour only for rectifying defects and making the fittings/fixtures functional. If replacement of parts/items is required to make the fittings functional the cost for labour and materials for the same shall be measured and paid for as “S&F in repairs” under relevant items of this Schedule hereinafter and in such cases the above items shall not be measured/paid. | 210 | Each | - | - |
| 3 | Taking down carefully copper point wiring (light, fan, socket and power) complete (fittings to be measured separately) and making good surfaces of walls/floors etc complete all as specified and directed. | 290 | Per Point | 10 | ₹2,900 |
| 4 | M&L for surface point wiring 1100 volts grade 1.5 Sqmm PVC insulated FRLS unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking in and including PVC casing & capping medium grade with all accessories on wall/ceiling /floor/roof etc, sunk pressed steel or cast iron terminal boxes with 3mm thick plastic laminated sheet top cover including 1.5 Sqmm PVC insulated FRLS unsheathed cable 1100 volts multistranded copper conductor conforming to IS:694:1990 with ISI marking as continuous earth wire connected to common earth dolly all as specified and directed for One light / fan point controlled by one switch. | 30 | Per Point | 10 | ₹300 |
| 5 | M&L for surface point wiring 1100 volts grade 1.5 Sqmm PVC insulated FRLS unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking in and including PVC casing & capping medium grade with all accessories on wall/ceiling /floor/roof etc, sunk pressed steel or cast iron terminal boxes with 3mm thick plastic laminated sheet top cover including 1.5 Sqmm PVC insulated FRLS unsheathed cable 1100 volts multistranded copper conductor conforming to IS:694:1990 with ISI marking as continuous earth wire connected to common earth dolly all as specified and directed for One 3 pin socket outlet 5 Amp on same board with other switches. | 20 | Per Point | 22 | ₹440 |
| 6 | M&L for surface point wiring 1100 volts grade 1.5 Sqmm PVC insulated FRLS unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking in and including PVC casing & capping medium grade with all accessories on wall/ceiling /floor/roof etc, sunk pressed steel or cast iron terminal boxes with 3mm thick plastic laminated sheet top cover including 1.5 Sqmm PVC insulated FRLS unsheathed cable 1100 volts multistranded copper conductor conforming to IS:694:1990 with ISI marking as continuous earth wire connected to common earth dolly all as specified and directed for One 5 pin socket outlet 5 Amp on independent board. | 35 | Per Point | - | - |
| 7 | M&L for surface point wiring 1100 volts grade 1.5 Sqmm PVC insulated FRLS unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking in and including PVC casing & capping medium grade with all accessories on wall/ceiling /floor/roof etc, sunk pressed steel or cast iron terminal boxes with 3mm thick plastic laminated sheet top cover including 1.5 Sqmm PVC insulated FRLS unsheathed cable 1100 volts multistranded copper conductor conforming to IS:694:1990 with ISI marking as continuous earth wire connected to common earth dolly all as specified and directed for One 3 pin 5 Amps socket outlet independent but below the switch board of light points in the same vertical plate. | 20 | Per Point | - | - |
| 8 | M&L for surface point wiring 1100 volts grade 2.5 Sqmm PVC insulated FRLS unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking in and including PVC casing & capping medium grade with all accessories on wall/ceiling /floor/roof etc, sunk pressed steel or cast iron terminal boxes with 3mm thick plastic laminated sheet top cover including 2.5 Sqmm PVC insulated FRLS unsheathed cable 1100 volts multistranded copper conductor conforming to IS:694:1990 with ISI marking as continuous earth wire connected to common earth dolly all as specified and directed for Power point on independent board and size of earthing cable 2.50 Sqmm. | 12 | Per Point | - | - |
| 9 | M&L for surface point wiring 1100 volts grade 4 Sqmm PVC insulated FRLS unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking in and including PVC casing & capping medium grade with all accessories on wall/ceiling /floor/roof etc, sunk pressed steel or cast iron terminal boxes with 3mm thick plastic laminated sheet top cover including 4 Sqmm PVC insulated FRLS unsheathed cable 1100 volts multistranded copper conductor conforming to IS:694:1990 with ISI marking as continuous earth wire connected to common earth dolly all as specified and directed for one 3 pin socket outlet 15 Amps Power point on independent board and size of earthing cable 4 Sqmm. | 13 | Per Point | - | - |
| 10 | M&L for point wiring with 1.5 Sqmm PVC (FRLS) insulated sheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continuous earth wire to common earth and connected to earth with 1.5 Sqmm PVC (FRLS) insulated sheathed multi stranded copper conductor cable draw in existing conduit complete all as specified and directed for One light/fan point controlled by one switch. | 65 | Per Point | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
Tender8584.pdf
Tender Documents • 0.85 MB
BOQ_892567.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .