Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 LAccepted-AOC 677A DIAMOND HARBAR ROAD HINDUSTAN PARK BEHALA KOLKATA 700034 | KOLKATA | KOLKATA | WEST BENGAL | 700034 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹3.1 L+₹20,321 (7.05%)Rejected-Finance 24A RABINDRA SARANI KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L2 | Rejected-Finance higher rate quoted | |
| 3 | L3₹3.6 L+₹67,914 (23.5%)Rejected-Finance 8 TOWNSHEND ROAD KOLKATA 700025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L3 | Rejected-Finance highest rate quoted |
Tender Value
Refer Docs
EMD Value
₹7,000
Closing Date
26 Sept 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE II CKHED
P 12 C I T Road 1st floor Kolkata 700014
SITC of AC machine and allied electrical works for the new minor OT room in Department of Dentistry at OPD Building under NRSMCH Kolkata
2022_WBPWD_399530_1
WBPWD/EE-II/CKHED/NIT-18/22-23
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
NRSMCH
AS PER NIT
4 documents required · 4 mandatory
₹7,000
P 12 C I T Road 1st floor Kolkata 700014
21 Oct 2022
30 Aug 2022
28 Sept 2022
30 Aug 2022
26 Sept 2022
7 Sept 2022
5 Sept 2022
Amount
Dismantling the Existing TPNDB and necessary connection and wiring and allied mending works.
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (RR Cable/KEI/ Gloster/Finolex) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/ Perspex (wall matching colour) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish as to GS. [E-14,2 ]
On board
Average run 10 mtr
S&F 415V 4 way double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall and mending good the damages to original finish incl. inter connection with suitable size of copper wire and neutral link & provision for earthing attachment, as per direction of the EIC. (D-10,14) Incoming - 415V 63A FPMCB isolator(1no) (D-5,6) Outgoing - 10KA 16-32A SPMCB-(12nos) (D-6,7) [Make : Legrand]
Supply & Fixing 240 V, 20 A plug socket (Make:- Anchor), without plug top and switch, on 100mm x 65mm sheet metal switch board with bakelite/perspex top cover by screws after making housing for combined plug switch by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc.( E4 -11.a & E5 .15.b)
Supply & Fixing 240 V, 2 nos 6/16A, plug socket with separate 2 nos 20 A Piano key type switch (Make:- Anchor) on sheet metal switch board embedded in wall incl. S & F 200x150x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. [E--5,14b,15b & E-4,10c]
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board. [ D-13,20a ]
Supply & delivery of 250V,Ac 18'' Inch sweep all metal body on wall bracket fan. [Make: EPC/Colour-Brown]as directed by EIC.
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length. [C-4,29 ]
Distribution wiring in 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed copper wire (RR Cable/KEI/ Gloster/Finolex) in 20/25mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required, as directed by EIC. (E-14,1a & 1b)
a) 4x(10 sqmm) + 2x(6 sqmm) as ECC
b) 2x4 sqmm + 1x2.5 sqmm
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets (make-dowels), tapes., as directed by EIC. (F-5,9)
a) 4x(10 sqmm) + 2x(6 sqmm) as ECC
b) 2x4 sqmm + 1x2.5 sqmm
Supply and fixing of 250V Timer DB (equivalent of 8 way SPN DB in size) with steel sheet enclosure double door, phosphatised powder coated , neutral bar, Din Rail with IP-43 protection comprises with 1 no. 20A/25A DP MCB ('C' Curve, 10 kA,), 1 no. 24 hours programmable Digital Time Switch with minimum switching time of 15 minutes and 1 no. 18A/25A contactor, single phase motor starter(compact-25A-min.) complete with internal wiring by suitable size of copper wire including 1 no. Auto Manual bypass MCB Changeover Switch and provision for earthing attachment including LED indication light and ON/OFF push button switch with locking arrangement. ( For 1.5 / 2.0 TR)(Make:- Legrand/L&T/equivalent arrangement of ABB). The work also includes S & D of PVC ‘FRLSH’ 1.1 KV Grade Copper wires in PVC Rigid Conduit(Make: Precision) 2 x 56/0.3 (4 sqmm) +1x 36/0.3 ( 2.5sqmm) up 12 Mtrs. [for AC M/C], as directed by EIC.
Supply & Fiixing of indoor type LED SIGN Board i) 4'(L)x1.5'(B)x0.5'(W) ii) 4'(L)x1.5'(B)x0.5'(W) fabricated from 3 mm thick ACP sheet on all six sides finished with approved metallic colour & suitable size hollow Al rectangular bar as frame inside the box. All LED Module, wiring to be fixed inside the ACP box. Silicon adhesives, SS screws to be used in such a way so that ingress of water can be restricted inside the box and maintenence / replacement of the LED modules can be done easily. All screws/nuts & bolts/clamps etc metals used inside the box should be of non-ferrous metal/Stainless steel.
Supply & Fixing of Special type of 3D Boxing type letter with top cover openable made from imported 3mm thick Acrylic sheet to accomodate LED module. Only front side of the letter should emit light. side to be made from opaque acrylic sheet. Letter height, width & depth of the letter will be proportionate & as per direction of E.I.C.. Suitable Ratio should be maintained between the letter size, spacing between each letters & spacing between each words as per the direction of the E.I.C. (Calculation of area (square inch) of a letter will be HeightXBreadth of the letter inclusive all wastage.
Supply & Fixing of LED within the acrylic letter from backside (Make: SAMSUNG-Korea) having the following specifications: COLOUR:WHITE or as per the choice of EIC. LIFE:70,000 burning hours. INTENSITY: Uniform without any bright/dark patches. VISIBILITY: 100Mtrs at least for normal eye vision. AMBIENT AIR: 0-50°C; 100% Relative Humidity. POWER CONSUMPTION: 1.5 Watt per module. (1 module consists of 3 nos LED) (Defect Liability Period-2 years )
SITC of water proof Power Supply unit to be fitted inside the Sign board box. inclusive of water tight gaskette fitted stainless steel hinged door box. Input: 100V-240V AC; 4A; 50Hz. Output: 12V DC; 17-20A constant power supply. Make: Meanwell/Ven/Resang or equivalent.(Defect Liability Period-2 years )
Supply & Fixing MS Structure for holding LED SIGN Board i) 4'(L)x1.5'(B)x0.5'(W) by 25x25x4 angle as Vertical members & strut at back side and 25x25x4 angle and 25x6 MS flat as horizontal member including painting the MS structure and fixing with RCC foundation on the roof as per direction of the EIC.
Supplying and Drawing 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed single core stranded copper wire (RR Cable/KEI/ Gloster/Finolex) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required
3 x 22/0.3 (1.5 sqmm)
Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction)
19mm dia 3mm thick Polythene Pipe
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint
Transpotatation charges of the above mentioned board frim work site to site, as directed by EIC.
S& Fixing GI sheet for covering the backside wall of LED Board (26 SWG)
Supply & Delivery of 2 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 24000 BTU/hr. with 1 Nos. rotary compressor, refrigerant R-410A, 1 nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-230V-1ph-50Hz. Air-flow/per IDU:- 650CFM. (Make: Carrier/ Voltas/ Hitachi/ O General/ DIAKIN)
Installation, Testing & Commissioning of Indoor & Outdoor unit of 2 TR capacity concealed type Split Air Conditioners after making hole in wall & necessary scaffolding arrangement etc as per site condition & direction of EIC including Supply of required Refrigerant R-410A, S&F of necessary fixing arrangement for indoor duly painted etc as per direction of the EIC.
Copper Refrigeration pipe line for liquid and suction line with fittings, elbows, bends, supports & brackets (Make-Ryoku/Totaline/Jobu/Nippon)
a) Liquid Line (1/4" OD with 0.6 mm thick)
b) Suction Line (5/8" OD with 0.7mm thick)
Supply & Fixing Pipe Insulation in liquid & suction line with 9mm nitrile rubber tube (Accoflex/Armacell/Supreme)
a) Liquid Line (1/4" OD with 0.6 mm thick)
b) Suction Line (5/8" OD with 0.7mm thick)
Supply and laying Control copper Cabling from Condensing Unit to control panel (Make: polycab/finolex/RR Kable/Gloster/KEI)
a) 4 core 2.5 sq.mm communication cable
S & L of Drain Water piping work out of PVC / HDPE hard pipes (Tata/Supreme) of following sizes incl. fitting, accessories, bends, elbows, tees, flanges, tapings, wall sleeves, hangers, supports, anchors.
a) 25 mm dia
Supplying, fabrication & fixing M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for making platform for installation of 2 nos. outdoor unit of 2 TR Concealed split and cassette AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 50 mm x50mm x 6 mm in each platform in outer edge for transmitting the load centrally through 2Nos. (50 mm x 50 mm x 6 mm) Angle inserted into the exiting wall. The entire structure should be barricaded & safe for ODU maintenance. Area of the platform is 3Mtr. x 1.2Mtr.or as per Machine configuration & load with adequate service access as per direction of EIC Structural design should be approved by E.I.C.
Cutting Iron window and Making door there for passege of outdoor installation and fixing.The charges of welder charges,mation charge,shifting,Fixing,labour charges and all material chips,Sand,Cement etc and mending good damages to original finish as per instruction of EIC.
Rate should be quoted incl. of all taxes and cess.
Defect Liability period : 1 year
STANDARD BUILDERS
SKY DECORATIONS PRIVATE LIMITED
techsummary_784159.pdf
PDF • 0.14 MB
finance_784159.pdf
PDF • 0.09 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_784159.pdf
PDF • 0.14 MB
WO.pdf
PDF • 0.70 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .