EE (EandM)/EDMC
Office of the Executive Engineer(EandM) Disaster Management Centre, Ghazipur, Delhi-96
Dismantling, Re Erection Testing and Commissioning of already installed Portable weighbridge Anti Smog Gun and allied accessories to designated location at SLF Ghazipur
2022_EDMC_102248_1
EE-EandM/EDMC//2021-22/14.2
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
15 days
work
Please refer to tender documents
4 documents required · 4 mandatory
₹500
₹9,000
3 Jul 2024
18 Jan 2022
25 Jan 2022
18 Jan 2022
24 Jan 2022
18 Jan 2022
120 days
Amount
Dismantling , re-erection , Testing and commissioning of complete system of installed Portable weighbridge , Anti- Smog Gun and allied accessories to designated locations at SLF ghazipur .
Supply of PVC insulated and PVC Sheathed Al conductor armoured cables conforming to IS1554 (Part-I)/1976 as required. (a) 2x10 sqmm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required (a) 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required(a) 2 X 10 sq. mm (19mm)
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.(a) Mild steel and Medium Tensile steel bars
Centering and shuttering including strutting, propping etc. and removal of form for all heights :Foundations, footings, bases of columns, etc. for mass concrete
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.. (a) Single pole
(b)Triple pole and neutral
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required (a) 63 Amp
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required (a) 63 Amp
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (a) 200 A 16 kA TP MCCB
b) 100 A 16 kA TP MCCB
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
S&F of compartmentalized cubical type panel board duly powder coated made out of 16SWG MS sheet with insulated allum. bus bar i/c interconnection, copper wiring arrangement for mounting for switch gears, changeover switches,MCCB i/c making the foundation brick work/angle iron frame on floor/wall with proper locking arrangement etc. complete as reqd. at site.(a ) Depth 15cm to 30cm
SITC of 150 Watt LED flood Light luminaire fitted with lens made of pressure die cast aluminium housing and toughened glass cover i/c mounting bracket complete with following specifications. a) LED Wattage 150 5% watt b) Luminaries efficien 90 lumens c) Pf 0.95 d) Protection IP-66
Sai Interprises
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .