Repair of existing structure at sewerage treatment plant Supplying installing testing and commissioning of 2 No centrifugal sewage pumping set Repair of Gen set disilting of sewer line and sewerage man hole and all other work contingent thereto
2026_WSS_161034_1
925
Open Tender
Civil Works
Percentage
90 days
Sri Anandpur Sahib
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
₹54,395
18 Feb 2026
18 Feb 2026
26 Feb 2026
18 Feb 2026
26 Feb 2026
18 Feb 2026
SEWERAGE SYSTEM
Disilting of manhole including all safety measures, cost of container T & P and disposal of silt upto 5km complete in all respects.(Internal Size 0.90 m × 1.50 m)
Depth upto 3 m.
Disilting sewers Pipeline jetting machines addopting all safety measures and disposal of silt upto 5km complete in all respects
First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth(for raising manhole opening height)
12.5 mm thick cement plaster 1:3
Cement rendering on plaster 1mm thick
Floating coat of 1:5mm thick neat cement laid in one operation to the topping
Dismantling and restoration of metalled road including loading / unloading of dismantled material, disposal of surplus / dismantled material etc complete in all respects, to the satisfaction of Engineer-in-charge.
Dismantling and restoration of cement concrete road with 50mm thick , cement concrete 1:2:4 on 100mm thick cement concrete 1:8:16 for full width of the street including loading / unloading of dismantled material, disposal of surplus / dismantled material etc complete in all respects, to the satisfaction of Engineer-in-charge.
Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD).
RCC Man hole cover with Frame
Extra Heavy duty
Heavy duty
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Dismantling concrete
Cement concrete plain1:2:4 mix
Conglomerate floor 40mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of materia
Dismantling brick work tile, masonry or tile lining
In cement
Providing & laying LDPE sheet below brick lining in bed & slope
First class flat brick paving or flooring laid over and in cement sand mortar 1:5 in ordinary bonded courses or in herring bone or other special courses, to templates, over dressed foundation and to correct longitudinal and cross slopes as shall be required by the Engineer-in-charge. All joints shall be filled with mortar and struck flushed as the work proceeds
On Bed & side slopes.
First class brick on edge 11.50 cm thick laid in reimbursements in and on 1:5 cement sand mortar.
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in charge).
100mm i/d Sluice Valves flanged
Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. Note: If Non-return valves class PN-1.6 is used instead of class PN-1.0 , than 5% will be paid extra
Class PN-1.0 as per ISI with rubber Flap
100mm i/d Non-return valve
Providing & fixing G.I. Barbed wire 2 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects.
Providing and Fixing precast pre-stressed cement concrete fencing pole M-40 by 4 Nos. parallel high tensile entwined wire (ISI marked wire 4 mm dia fencing pole size at bottom 4" x 4", size top 3" x 4",Lenght 6ft, hooks 6 No. including cost of excavation, sand filling and erection complete in all respects
Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm.
Repair of footpath concreting of footpath and other contigent work complete in all respect (as per analysis)
Providing and fixing Sign board ,Painting and writing scheme detail over sign board as per analysis
PUMPING MACHINERY
For Inlet collecting tank
(a) Supplying & installing testing and commissioning 2 No (1+1) one no working and one no is stand by . each centrifigule sewage pumping set capable of delivering 550 LPM as per requirement at 15 m head complete with column pipes, submersible cables holding clamps to the entire satisfaction of Engineer in charge (Suggested 5 HP ) for Influent Collecting Tank
Repair of composting pits 4 m x 8 m x 1.5 m (2 Nos.) plaster works, railing repair , paint and other contigent works.complete in all respects (as per analysis)
Providing and placing in horizontal layers filtering media screened, washed and cleaned as described below:-
Repair of Sludge curing Platform 1.5 m x 3.0 m (1 No) plaster works and other contigent works.complete in all respects (as per analysis)
First class burnt work laid in cement sand mortar 1:7 in foundation and plinth
Plinth Protection to Pump Chamber conglmentic floor 40mm thick CC 1:2:4 on 100mm cement conc.1:8:16 & 100mm sant stone filling
Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats on old distempered work when shade is changed
Finishing walls with exterior decorative cement based paint such as snowcem, robbiacem etc. two or more coats to give an even shade
Recessed conduit pipe wiring system
Wiring in PVC insulated aluminium conduct cable left (Complete as per CSR) with caster on fan base
Wiring fan points cable in 1.5mm2 (1/1.40mm)
Wiring light point in 1.5mm2(1/1.40mm) cable
Wiring 6 Amp wall socket point
Wiring 16/20Amp. power plug control point
Providing & fixing of ceiling fan of reputed make such as Compton or equivalent
Providing & fixing of electrit tube set of reputed make
Providing & fixing of Electric Bulbs
Provision of Lawns and Tree Plantation at the STP Site
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 meters including removal and disposal of top organic soil not exceeding 150 mm in thickness as per technical clause 201 of MORT&H specifications
In area of Light Jungle (By Manual Means)
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank.
Triple Layer Tanks
First class brick on edge paving or flooring laid over and in cement sand mortar 1:4 in ordinary bonded courses or in herring bone or other special courses, to templates, over dressed foundation and to correct longitudinal and cross slopes as shall be required by the Engineer-in-charge. All joints shall be filled with mortar and struck flushed as the work proceeds.(for walkway around tanks)
Repair of generator set 10 KVA on CC foundation including making connection with panel board change over switch etc. complete
Dressing bed and preparation of subgrade for lining
Dressing side slopes and preparation of sub grade for lining.
Cement concrete 1:8:16
With stone aggregates 40mm gauge
mixing by mechanical means using concrete mixer volumetric type
Excavation in trenches with straight or open cutting in streets, lanes or in open areas for intramural sullage drains, intramural intercepting drains and outfall drains storm water channels and other work contingent or incident thereto, by mecanical means (JCB or Hydraulic excavator) including manually dressing of bed, trimming of sides and sides slopes to full dimensions and depth as shown on the drawings or as shall be required by Engineer-in-charge including dressing to correct sections and dimensions according to templates and levels, dewatering of rain water, diversion of traffic, providing and fixing and maintenance of caution boards, fencing, night signals, watching etc. subsequent refilling , watering and dressing upto ground level for lead upto 15 m and for all lifts including disposing surplus soils up to 15 metre complete in all respects.
Depth upto 2.00 m.
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.
Single Socket Type B
160mm o/d SWR UPVC pipe lines laid complete
Provision for electricity connection re connection
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.75 MB
NewdnitAbiana.pdf
Tender Documents • 2.24 MB
BOQ_326667.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .