Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 LAdmitted-Finance WARD NO 09 THANA ROAD BIRSINGHPUR PALI DISTT UMARIA M P 484551 | BIRSINGHPUR PALI | UMARIA | MADHYA PRADESH | 484551 | ₹8.2 L | L1 | Admitted-Finance |
| 2 | L2₹11.1 L+₹2.9 L (35.1%)Admitted-Finance 12 156 POLICE LINE BY PASS ROAD SHAHDOL 484001 M P | SHAHDOL | SHAHDOL | M P | 484001 | ₹11.1 L+₹2.9 L (35.1%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Submitted annexure IX is on stamp paper of Rs 100 only instead of Rs 200 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Submitted document is not inline with PQR clause 5a |
| Sl No | Description | Qty | Unit | AMIT TRADERS L1 | Ashish Enterpirses L2 |
|---|---|---|---|---|---|
| 1.00Supply Part :- | |||||
| 1.01 | Supply of Gas Monitoring System :
• DISPLAY - Intelligent Alphanumeric 16 x 1 Characters LCD Type with Back-lit Facility
• DISPLAY INFORMATION - Scrolling CH. No. with 2-digit % LEL / PPM Data and status
• INDICATIONS - 4 LED’s per CH. for HEALTHY, WARN
(Limit 1), ALARM (limit2), FAULT.
• CONTROLS - ACCEPT, RESET
• Channel: 4 nos.
• ALARMS - 2 Preset Alarms ( WARN & ALARM) in % LEL / PPM Range for each CH
• OUTPUT - SPST Relay Contact each for MASTER ALARM & FAULT
• ACCESSORIES - FLP Cable Glands as required.
• MAINS Supply - 230 VAC, 50 Hz
• ENCLOSURE - Wall Mounting WP Enclosure for Safe Area Installation | 2 | set. | 2,40,000 ₹2,83,200 Lowest | 5,04,000 ₹5,94,720 |
| 1.02 | Hydrogen Gas Detectors :
• Gas detection type :- Catalytic
• Detected Gas :- H2
• Measuring range :- 1% LEL between 0- 60% LEL
• Accuracy: - +/- 3% L.E.L.
• Repeatability: - +/- 3% L.E.L.
• Zero Drift :- Less than 2% Full scale/month
• Response time :- 90% in less than 15 secs
• Sensor Housing :- Stainless steel type 316 L
• Load impedance :- 47 Ohm max
• Ingress protection: IP 66
• CEM mark :- EN 50270
• Operating Temperature :- -45 to+ 80 deg C
• Storage Temperature :- -55 to+ 95 deg C
• Humidity: 10 to 90% Rh Non-condensing
• Poison Resistance: - Sulphur compounds & Lead compounds have no effect. Chlorine & Silicon cause loss of sensitivity.
• Area Classification: Zone-1, Class-1, Ex s d II C T5 as per SAA Ex-228 Certification: SAA Ex-228 CCE R.1 (1) 138/GAS TECH/ 120 | 6 | Nos. | 3,24,000 ₹3,82,320 | 3,02,400 ₹3,56,832 Lowest |
| 1.03 | Supply of Sensor Mounting Accessories | 6 | Nos. | 42,000 ₹49,560 Lowest | 50,400 ₹59,472 |
| 1.04 | Calibration Kit :
Standard (2.0% Hydrogen Bal. Air) Equiv. to 50 % LEL known concentration of Calibration Gas Mixture in 3 Ltr Cylinder at 100 kg. Pressure. Flow Meter, Regulator and
Pressure Gauge with rubber tube. Calibration Cap | 1 | Nos. | 48,900 ₹57,702 | 42,000 ₹49,560 Lowest |
| 1.05 | Installation & Commissioning Charges | 1 | job. | 40,000 ₹47,200 Lowest | 40,000 ₹47,200 Lowest |
Tender Value
₹13.6 L
EMD Value
₹27,200
Closing Date
13 May 2026, 3:00 pmClosed
SE PnW SGTPS,MPPGCL,Birsinghpur
SE PnW SGTPS,MPPGCL,Birsinghpur
Supply, Installation and Commissioning of New Hydrogen Gas Leak Detection System in Hydrogen Plant SGTPS, MPPGCL, Birsinghpur.
2025_MPPGC_471437_1
471437
Open Tender
Electronics Equipment
Item Wise
SE PnW SGTPS, MPPGCL, Birsinghpur
Please refer Tender documents.
17 documents required · 17 mandatory
₹1,000
Yes
₹27,200
Yes
14 Aug 2026
18 Mar 2026
15 May 2026
18 Mar 2026
13 May 2026
18 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply Part :- | |||||
| 1.01 | Supply of Gas Monitoring System :
• DISPLAY - Intelligent Alphanumeric 16 x 1 Characters LCD Type with Back-lit Facility
• DISPLAY INFORMATION - Scrolling CH. No. with 2-digit % LEL / PPM Data and status
• INDICATIONS - 4 LED’s per CH. for HEALTHY, WARN
(Limit 1), ALARM (limit2), FAULT.
• CONTROLS - ACCEPT, RESET
• Channel: 4 nos.
• ALARMS - 2 Preset Alarms ( WARN & ALARM) in % LEL / PPM Range for each CH
• OUTPUT - SPST Relay Contact each for MASTER ALARM & FAULT
• ACCESSORIES - FLP Cable Glands as required.
• MAINS Supply - 230 VAC, 50 Hz
• ENCLOSURE - Wall Mounting WP Enclosure for Safe Area Installation | 2 | set. | - | - |
| 1.02 | Hydrogen Gas Detectors :
• Gas detection type :- Catalytic
• Detected Gas :- H2
• Measuring range :- 1% LEL between 0- 60% LEL
• Accuracy: - +/- 3% L.E.L.
• Repeatability: - +/- 3% L.E.L.
• Zero Drift :- Less than 2% Full scale/month
• Response time :- 90% in less than 15 secs
• Sensor Housing :- Stainless steel type 316 L
• Load impedance :- 47 Ohm max
• Ingress protection: IP 66
• CEM mark :- EN 50270
• Operating Temperature :- -45 to+ 80 deg C
• Storage Temperature :- -55 to+ 95 deg C
• Humidity: 10 to 90% Rh Non-condensing
• Poison Resistance: - Sulphur compounds & Lead compounds have no effect. Chlorine & Silicon cause loss of sensitivity.
• Area Classification: Zone-1, Class-1, Ex s d II C T5 as per SAA Ex-228 Certification: SAA Ex-228 CCE R.1 (1) 138/GAS TECH/ 120 | 6 | Nos. | 1 | ₹6 |
| 1.03 | Supply of Sensor Mounting Accessories | 6 | Nos. | 2 | ₹12 |
| 1.04 | Calibration Kit :
Standard (2.0% Hydrogen Bal. Air) Equiv. to 50 % LEL known concentration of Calibration Gas Mixture in 3 Ltr Cylinder at 100 kg. Pressure. Flow Meter, Regulator and
Pressure Gauge with rubber tube. Calibration Cap | 1 | Nos. | 3 | ₹3 |
| 1.05 | Installation & Commissioning Charges | 1 | job. | 4 | ₹4 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.75 MB
NIT471437.pdf
Tender Documents • 0.74 MB
Tenderschedule471437.pdf
Tender Documents • 0.61 MB
SBDTurnkey.pdf
Tender Documents • 2.71 MB
biddersbd.pdf
Tender Documents • 0.24 MB
DetailsOfBidder.xls
Additional Documents • 0.03 MB
TCBid471437.xls
Additional Documents • 0.39 MB
checklist471437.pdf
Additional Documents • 0.45 MB
BOQ_581012.xls
BOQ • 0.23 MB
546.pdf
PDF • 0.68 MB
439.pdf
PDF • 0.53 MB
177.pdf
PDF • 0.62 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .