| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.8 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹12.5 L+₹28,661.80 (2.35%)Rejected-Finance | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹12.6 L+₹42,908.60 (3.52%)Rejected-Finance 2 B KRISHNA NAGAR AMBALA CANTT | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹12.9 L+₹73,281.20 (6.02%)Rejected-Finance ZIRAKPUR PUNJAB | S A S NAGAR | PUNJAB | 140103 | L4 | Rejected-Finance Being not lowest |
Tender Value
₹11.8 L
EMD Value
₹26,000
Closing Date
18 Mar 2020, 6:00 pmClosed
Lt Col Sidhartha Singhal
GE (P) Dappar
Special Repair to Railway gate at Mil Stn Dappar under GE (P) Dappar
2020_MES_316315_2
GE(P)DPR-38/2019-20
Open Tender
Civil Works
Works
180 days
GE (P) Dappar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
₹26,000
Yes
14 Aug 2020
24 Feb 2020
20 Mar 2020
24 Feb 2020
18 Mar 2020
4 Mar 2020
24 Feb 2020 - 4 Mar 2020
Amount
Demolition of reinfoced cement concrete of any description and in any position not otherwise specifically demolition provided for(reinfocement should be cut as required to facilitate demolition) complete all as specified and directed by Engr-in-Charge.
M&L Cement concrete in foundations, filling and mass concrete type D2 1:4:8 all as specified.
M&L RCC in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc basement slabs, under-reamed piles and mass concrete in type B0 1:1/2:3 all as specified.
M&L RCC in Beams, cantilevers, bressummers, lintels over 1.5m span in type B0 1:1/2:3 all as specified.
M&L RCC in Columns, pillars, piers, posts and struts in type B0 1:1/2:3 all as specified.
M&L Mild steel TMT bar 10mm dia and over, cut to length, bent to shape required including cranking bending spirally for hooping for column, hooking ends and binding with and including mild steel wire (annealed ) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge.
M&L Mild steel TMT bar 5 mm dia and over upto and including 10 mm dia in stirrups, spaces and binders, cut to length, bent to shape required including cranking bending spirally hooping for column, hooking ends and binding with and including mild steel wire (annealed ) not less than 0.9mm dia or securing with clips quality conforming to, as in stirrups, spaces and binders complete all as specified and directed by Engr-in-Charge.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter to flat all as specified.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) all as specified.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc all as specified.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions all as specified.
Demolition of brick work built in cement morter etc complete all as specified.
M & L brick work with subclass 'B' bricks straight or curved on plan to any radius bull in CM 1:6, complete all as specified and as directed.
M&L for cement plastering 15mm thick in two layers (10mm and 5mm respectively) in cemet mortar 1:4 including mixing of liquid water proofing compound as per manufacturer's instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and smooth without using extra cement and fixing of chicken wire gauge where directed complete all as specified and as directed by Engineer-in-Charge. Note : WPC will be measured and paid separately.
Supply only integral liquid water proofing compound complete all as specified & as directed by Engineer-in-Charge. Make : Pidilite/Sika
M&L for applying acrylic thick wall care putty on internal/external surfaces of walls/ceilings/soffits (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed. Make of wall Putty : JK wall Putty / Birla Wall care Putty / Bison Wall Putty. Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further finishes. Please note that the further finishes work will start only after approval of the prepared surface from the GE as well as to the Engineer-in-Charge through site order.
Applying 02 coats of exterior emulsion paint (light shade) @ 5 sq.m/litre/2 coats by using roller/brush to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq.m/litre/1 coat as recommended for under coat by manufacturer of exterior emulsion by using following brands of emulsion and primer complete all as specified and directed. Make of Exterior Wall Primer : Asian / Berger / Nerolac [Best Quality]. Make of Exterior Emulsion : Asian (ACE) / Berger (WALMASTA) / Nerolac (SURAKSHA SUPERIOR)
M&L for cement plastering 10mm thick in cement mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
(a) Applying acrylic thick wall care putty on internal surfaces of walls (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving exterior painting complete all as specified and directed. Make of wall Putty : JK wall Putty / Birla Wall care Putty / Bison Wall Putty. Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further external finishes. Please note that the further external finishes work will start only after approval of the prepared surface from the GE as well as to the Engineer-in-Charge through site order.
M&L for applying 02 coats of interior emulsion paint (light shade) @ 10 sq.m/litre/2 coats by using roller to wall surfaces over & including a coat of interior wall primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer complete all as specified and directed. Make of Interior Wall Primer : Asian / Berger / Nerolac [Best Quality]. Make of Interior Emulsion : Asian (TRACTOR) / Berger (BISON) / Nerolac (BEAUTY SMOOTH) .
Dismantling wrought iron or mild steel work of any description not otherwise provided for angle iron or flat iron as in post and guard bar or grating complete all as specified and directed by Engr-in-Charge.
Providing and fixing factory made extruded aluminium casement windows with 50 micron powder coating doubled panelled and double shutters consisting of frame and mullion of 101.60 X 44.45 X 1.29 mm and shutters made of 63.5 X 31.75 X 1.29mm and to be fixed with and including EPDM gasket to render the glazing, air and water tight etc. & aluminium beeds 20mm size with and including 5mm thick glass in front shutters and stainless steel wire gauge 0.36mm dia and 1.40 aperature in inner shutters complete fixed in all respect as specified including supply and fixing following items :- (a) Stainless Steel (304 Grade) Finished Butt Hinges 150mm - 2 Nos per leaf. (b) Powder Coated Aluminium Tower Bolt 150mm long - 2 Nos per leaf. (c) Powder Coated Aluminium Handles 150 mm - 1 Nos per leaf. Make (Aluminium Sections) : Jindal/Valco/Galco/Hindalco or equivalent as approved by AO
S&F factory made aluminium 50 micron powder coated grill, opening size 101.6 X 63.5 mm (4"X2½") and of approx weight @ 1.345 Kg/sq.m complete fixed in position in windows in all respect as specified
S&F Spray Docu painted Pressed steel frames made of MS sheet of 1.20 mm thickness for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, hold fast etc., complete all as specified, size 105 x 60mm and incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified and directed.
M&L for cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in holdfast blocks all as specified
S&F factory made flush shutters 35mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides with 6mm thick lipping frame to match including supply and fixing following items : (a) Stainless Steel (304 Grade) Finished Butt Hinges 150mm - 4 Nos per leaf (b) Stainless Steel (304 Grade) Finished Tower Bolt 200mm long - 2 Nos per leaf (c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 Nos per leaf (d) Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16 x 300mm - 1 No per leaf (e) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 No per leaf
M&L for Baroda Green marble, machine cut as in shelves/steps/cills/jambs/skirting/border only in tile flooring and the like works and flooring etc, 15-16 mm thick including bull-nose the exposed sides/lengths, set and jointed in cement slurry over & including screed of 15 mm thick rendering in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab for fixing on concrete surfaces or with suitable adhesive for fixing on un-polished kota stone slabs including rubbing, cutting and mirror type granite polishing and including dismantling/demolition complete all as specified. Note : Single piece should be used in steps/cills/jambs/shelves.
Dismantling wrought iron or mild steel work of any description not otherwise provided for angle iron or flat iron as in post and guard bar or grating complete all as specified and directed by Engr-in-Charge.
S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe -290 Gde E-165 complete all as specified and directed by Engr-in-Charge.
Preparation of newly or previously untreated steel surfaces, of any description, over 10 cm width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge.
Dismantling of existing lettering and refixed after repair of gate all as specified and directed
M & L for Granite stone slab 19/20 mm thick of any type polished to any surface and any description over 20mm screed bed in CM 1:4 complete all as specified.
S&F wall hanging watch 1.0m dia with all fitting in beam of gate all as specified and approved by GE
S&F Thermoplastic Circuit Breaker Boxes, IP 65 class (with metric knockouts for cable entry) including suitable size copper bus-bar, cable glands, etc. of 240V, 12 Modules complete all as specified and directed. NOTE - (a). Cost of suitable size cable lugs and materials required for flush fixing of DB is deemed to be included in the quoted rate. (b). Cost of cutting chases in wall for flush fitting of DB and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quoted rate.
S&F MCB single pole and neutral, 6-32 Amps, 240 V, 'C' series all as specified and directed by Engr-in-Charge.
S&F MCB, single pole, 240 V, 6 to 32 Amps, 'C' series all as specified and directed by Engr-in-Charge.
Supply and draw sub main wiring with two runs of 1.5 sqmm, single core FRLSH PVC insulated unsheathed multistranded copper conductor cable drawn through and including non-metalic PVC conduit with all connected accessories concealed in wall, floors, etc including one run of single core FRLSH 1.5 sqmm PVC insulated unsheathed multistranded copper conductor cable for earth continuity, green in colour, all as specified and directed by Engr-in-Charge. Note : (i) Two runs of copper conductor cable and one run of copper earth wire including PVC conduit will be measured and paid as one unit only. (ii). Suitable size cable lugs copper fabricated will be measured in the quoted rate only. (iii). Cost of cutting chases in wall for flush fitting of DB and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate.
M&L Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge o the plate not less1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts nuts, check nuts and washers of galvanized iron of steel all as shown in electrical plate No.5 connected to earthing test point incl necessary earth work, excavation PCC 1:3:6 type CI using 20mm graded stone aggregate for earth chamber provn of PCC cover 40 mm thick 1:2:4 mm type B1 funnel with water Pipe, GI pipe, 15mm dia medium grade protection pipe, GI earth lead all as directed by Engr-In- Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.0 sq mm 4 core all as specified and directed.
Excavation in trenches not exc. 1.5 mtr wide and not exc. 1.5 mtr depth and getting out in any type of soil including taking out faulty cable/cable covers and GI pipe complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layers n.exc 25 cm complete all as specified & directed.
Removing excavated materials n.exc 50m and depositing where directed at a level n.exc. 1.5m above the starting point.
M&L for dry river sand as sand cushioning for protection of UG cable including punning of sand in layers all as specified.
Supply & laying un-reinforced precast concrete cable cover class LV type 1, flat size 250mm x 150mm x 40 mm all as specified & directed.
M&L for supplying, laying/fixing GI pipe medium grade with all fittings for protection of UG cable to be laid in trenches/to be fixed on wall/pole/panel/nala/road crossings complete as specified for the 50mm bore of pipe all as directed.
S&F weather proof landscaping colour changing LED luminarie, 36W made out of hard chrome plate stainless steel with silicon sealed glass to be fixed on wall, PCC/bituminous floor/road, etc. and incld. All necessary accessories required all as specified and directed by OEM and as approved by Engr-in-Charge all as per Wipro make Cat No. LU03-371-030-CC-XX or equivalent in Philips/Bajaj.
S&F weather proof wall grazing wall mounting LED luminarie, 12W made out of die-cast aluminium body to be fixed on wall, PCC/bituminous floor/road, etc. and incld. all necessary accessories required all as specified and directed by OEM and as approved by Engr-in-Charge all as per Wipro make Cat No. LW33-101-025-30-XX or equivalent in Philips/Bajaj.
SONY ENTERPRISES
M/S Mahal Enterprises
SS BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .