PROVN OF STORAGE FACILITY FOR P-IV SYSTEM AT AF STN BHISIANA
2024_MES_650383_2
CEWAC/BHI/T-11/2023-24
Open Tender
Civil Works
Lump-sum
730 days
GE (AF) BHISIANA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
GE (AF) BHISIANA
₹6.0 L
Yes
8 Jul 2025
8 Oct 2024
6 Jan 2025
8 Oct 2024
4 Jan 2025
18 Dec 2024
Amount
SCHEDULE `A' PART - I (Building / Structure Works) is not prepriced by MES and prepriced rates indicates 0.00 under column 5 signifies this fact only.
Construction of ESH Building of size 21mx18m and 7.5m height without traverse complete with permanent specification as specified and as shown in drawings. Note : Lump Sum cost does not include Steel double leaf door (02 Nos), Loading Platform & Ramp for ESH Bldg, Traverse Wall (VIFT), Varying Height Retaining Wall & Toe Wall.
Construction of AC Plant Room (Size 13m x9mx5m) complete with permanent specification as specified and as shown in drawings.
Construction of AHU Room (Size 5m x3mx7.5m) complete with permanent specification as specified and as shown in drawings.
Provision of blast proof steel double leaf door for opening size 5.0Mx3.5M based on EPC mode complete with all fittings/fixtures. Design to be undertaken by the contractor duly vetted by IIT/NIT and therafter approved by Accepting Officer. Steel sheet to be used shall not be less than 12 mm thick
Provision of blast proof steel double leaf door for opening size 2.5Mx2.5M based on EPC mode complete with all fittings/fixtures. Design to be undertaken by the contractor duly vetted by IIT/NIT and therafter approved by Accepting Officer. Steel sheet to be used shall not be less than 12 mm thick
NOTE: Schedule ‘A’ Part II to XI under Ser No 2.01 to 2.10 are Prepriced by MES.
Lump sum price worked out by the Contractor for “ SITE CLEARANCE, EXCAVATION AND EARTH WORK” as listed in Schedule ‘A’ Part II
Lump sum price worked out by the Contractor for “LOADING PLATFORM AND RAMP FOR ESH BLDG, TRAVERSE WALL (VIFT), VARYING HEIGHT RETAINING WALL & TOE WALL ” as listed in Schedule ‘A’ Part III
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION WORKS" as listed in Schedule ‘A’ Part IV
Lump sum price worked out by the Contractor for "AREA DRAINAGE” as listed in Schedule ‘A’ Part V
Lump sum price worked out by the Contractor for “ROAD, PATH AND CULVERT ” as listed in Schedule ‘A’ Part- VI
Lump sum price worked out by the Contractor for “SECURITY FENCING AND GATE WORKS” as listed in Schedule ‘A’ Part - VII
Lump sum price worked out by the Contractor for “STATIC WATER TANK OF CAPACITY 110 KL” as listed in Schedule ‘A’ Part -VIII
Lump sum price worked out by the Contractor for "EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part IX
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part X
Lump sum price worked out by the Contractor for "LIHGTENING PROTECTION” as listed in Schedule ‘A’ Part -XI
SCHEDULE `A' PART - XII MISC ITEMS (B/R & E/M) is not prepriced by MES and prepriced rates indicate 0.00 under column 5 signifie this fact only.
Supply of good earth delivered at site inside AFS Bhisisna, to be filled in earthen traverse complete all as specified and as directed. (Good Earth as approved by GE shall be arranged by contractor at his own cost from out side of MD land.)
S&F Fire symbol display board of size 1200 x 900 mm made out of alumunium sheet 2 mm thick with Stainless steel frame using 25x15 mm rectengular pipe with 35 mm dia SS pipe in outer border all around retro reflective high intesity 400 micron thick blue/yellow colur sheet pasted with heating process on both sides of the board including 75-100 mm high black colour letters cut to shape with special plotter and in proper manner indicating shed no as directed and 2 nosx 75 mm dia SS pipe glossy finish with MS plate 3 mm thick welded to bottom of pipes for fixing of board and shall be suitably embeded in ground using PCC 1:2:4 including earth workk/excavation as directed complete.
Supply and fixing concertina coil 610mm dia (50 turn/coil) expandable 6-8mtr (short barbs) barbs length 11+-1mm thickness of tape 0.50mm, dia of spring core wire 2.60mm fixed on angle iron frame including securing or tying at crossing with and, staples or steel pins etc complete all as specified and as directed.
S & F SPN 8 way flame proof enclosure size 330x350x190mm lighting distribution panel incoming MCB DP, 32A-01No and out going MCB 1 pole 6A-06 Nos with complete internal busbar and wiring upto terminals complete all as specified and as directed.
Design, Supply, installation, commissioning & testing suitable type of Central AC plant for above proposed storage bldg. Requirement of Minimum capacity of Compresssor - 1x50 TR for running & 1x30 TR for standby including suitable capacity of water pump sets, panel, cooling tower, ducting, winter heating and humidification etc complete as required for proper functing to achieve the users requirement. Note:- The TR capacity of AC is considerd as minimum. However during the DPR stage if tunnage will exceed, the contractor shall install the same without any extra cost. The following aspects shall be accounted for preparation of DPR & execution of work (Rate to be quoted for considering Compresssor - 1x50 TR for running & 1x30 TR for standby as one unit)
a) The contractor shall get DPR prepared from the specilized agency having adequate exeprience in the field & get it vetted from the IIT/NIT. The DPR duly vetted by IIT/NIT will be submitted by the contractor to Accepting Officer for approval. (b) DPR shall be prepared keeping in view of undermentioned guidelines. The contractor may optimize to deliver the best results applying their mind to meet out the User`s desired goal. (c) Construction of AC plant room covered under item No 1.10 in which, AC plants/equipments are to be accommodated. (d) Tentative temperature chart & Ground water analysis and its suitability (Water test report) for air conditioning shall be provided by the GE and accordingly water treatment shall be suggested, if any.
(e) Calculations of Electric load for AC plant & its connected accessories. (f) Provision of insulation on ceiling/wall as per DPR for efficient & economic operation of AC system. However ceiling as shown on drgs is included in unit rate of item No 1.10 (g) Detailed heat load calculations to achieve inside design conditions for storage bldg. The user data sheets duly signed may be considerd for calculation of AC plant as per Appendix 'A' of the tender documents. The outside conditions shall be as per meterologincal records/ASHRAE. Heat load calculations sheets for summer monsoons and winter seasons shall be submitted alongwith the psychometric chart and detail calculation. Tentetive details (Inside/outside conditions) for guidance only are given in particular specifications.
(l) Complete DPR includes design & drgs in triplicate alongiwth CD. (m) Provison of earthing with GI earth plate 600x600x6mm and 32x6mm GI strip all as specified. (n) Testing of Plants as specified. (o) Cost of all above factors shall be deemed included in unit rate/lumpsum. Nothing extra shall be paid for any misunderstanding or miscalculations whatsoever. (p) Lump sum quoted by the contractor shall be deemed to include all relevent items of works/details though not specifically shown here but are essential for execution in workman like manner & sound engineering practice to achieve desired goal.
Supply and installation, testing and commissioning of flame proof 2 Ton capacity EOT crane (class-II, Medium duty ) double girder type with all motion i.e Long travel 18 mtr, Cross travel 21mtr, and height 5 Mtr of lift with complete confirming to IS/IEC-60079-1:2007, PVC shrouded bus bar (GI) Type DSL system , limit switch and LT rails as per manufacturer (OEM) with its accessoories, floor operated with pendent push button from the floor. The flame proof Panel shall be with VVVF drives for all the three motions with main incoming breaker/switches, transformer, contractors, relay, fuses, indicating lamp etc.MCB is provided in the control circuit of each motion , each break circuit is provided with suitable contactors, all wiring with suitable size copper conductor. Plateform should be full length, anti skid steel, hand railing should be provided on drive side of the crane and 2 Nos and short plateform shall be provided on the other side. (o) Micro speed -10%
The crane shall be painted with one coat of red oxide and two coats of epoxy paint having the following components specification and provision of manual operation. (a) Capacity 2 Ton (b) Design standard as per IS-3177,807, IEC-60079-1:2007 (c) Class/Duty -M6,Medium,Indoor duty (d) Item - double girder EOT 2 TON Capacity crane (e) Hoist speed - 3 MPM (f) creep speed - 10% (g) cross travel speed - 8 MPM (h) long travel speed -12 MPM (j) operation pendant operated (k) Span 21 mtr (l) lift -5 mtr (m) long travel length -18 mtr (n) VVVF drive for all motoion three motion
Supply , laying , jointing and testing of DI Pipe of size 100 mm dia including jointing material in trenches complete all as specified and as directed.
M&L for brick masonary valve pit of size 90 cm x 90 cm x90 cm (internal of chamber ) depth of chember to be reckoned from the top of PCC in foundation to top the MS cover as 60 cm and including MS sheet cover fabricated from 3.15 mm thick MS sheet and frame of angle iron 50 mm x 50 mmx5 mm with fixing arrangement , hinges and locking arrangement and painting two coat of synethetic enamel paint over a coat of red oxide primer on MS cover and frame , inlcuding necessary excavation and earth work in any type of soil , returning , filling in approved soil disposal of surplus soil to a distance not exc.50 mtr , 150 mm thick PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation , brick work in cement motor (1:6) 15 mm thick plastering in cement mortoar (1:4) (both internally and externally) 100 mm thick PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in flooring complete all as directed suitable for upto 100mm dia.
Supply, Installation, testing and commissioning of HT 11 KV, 630 A having short circuit capacity 21 KA/3-sec, Outdoor suitable, RMU SF6 Comprising of motorised 1 No. load break switch & 2 Nos outgoing VCB, spring charging with electrolyte grade copper busbars and all gas filled, robotically welded stainles steel 304 (Non Ferrite Non Magnetic grade) tank with minimum thickness 3±.5 mm, with IP 65 protection. The Mimic board shall with IP2X & outdoor enclosure shall be minimum IP 54 & IP55+ IP3X for cable compartement. Any accidental over pressure inside the sealed chamber shall be limited by the opening of a pressure limited device provided in the rear part of the tank & internal fault IAC AFLR-21kA for 1 sec as per IEC 62271-200 or latest IS. The unit along with Bus-connected, Fixed-type Potential Transformer shall include different modules as described below. (01 Nos as incomer,02 Nos as outgoing) Each function-Unit consists of VCB in combination with 3 position switch. 11KV, 630A fixed type VCB module with series disconnector cum earthing switch of SCB current/ withstand-21kA/3-sec making capacity-52.5 kAp, Aux. contacts-6No+6NC, Stored-energy manual high endurance spring charging mechanism, with inbuilt spring-charging lever & mechanically latched ON/OFF push -buttons to allow handle -less & un-inhibited operation. 3. Each incoming VCB shall be integrated with self powered type relay with protectiona against Non-Directional Over current & Earth fault in any of 3 Phase. Capacity voltage indication fixed type system with LED Display. ON, OFF, trip indication fixed type on the front mimic of the panel.Set of 3 nos. ring-core cast-resin insulated protection (CI.5P10,2.5VA) and metering (CI.1.0,2.5VA) CTs having ratio of 100/50/1-1. Digital Multifunction Meter (Accuracy Class 0.5). 1 No. Bus-connected,fixed-type PT Compartment to provide required metering voltage.Operation Handle for Manual Isolator/ Disconnector/ Earthing Operation. Standard Manometer. Operation and Maintenance Manual. Note:- (a) Drawing for panels shall be approved by AO before placement of Order by Contractor. (b) The rate for making the foundation / padestal for RMU of requrid size, excavation, brick work, concrete shall be included in the quoted rate as per recommendation by the Manufacturer.
S&F of Dry Chemical powder fire extinguisher 6 kgs capacity stored pressure for ABC type fire ISI certified complete all as specified and as directed.
S&F of carbon di oxide fire extinguisher portable type 4.5 kgs capacity BC type fire ISI certifiedcomplete all as specified and as directed.
S&F of clean agent type multipupose type powder fire extinguisher 6.0 kgs capacity ABC type fire ISI certified complete all as specified and as directed.
Supply, Installation, testing and commissioning of HT 11 KV, SF6 both side Extendable 400 A having short circuit capacity 21 KA/3-sec, Outdoor suitable, RMU Comprising of 1 No. load break switch SF6 Gas as insulation IEC 62271-200 . The unit shall have front cable entry for ease of installation. LBS should be compelte with all accessories such as cable supports all front cable terminations, emchaical indications for load break switch ON/OFF. The Mimic board shall with IP2X & outdoor enclosure shall eb minimum UP-54 & IP55+IP3X for cable compartment. Any accidental over pressure inside the sealed chamber shall eb limited by the opening of a pressure limited device provide in the rear part of the tank as per IEC 62271-200 or latest IS-200 or lates IS. The unit shall include the followign with all necessary standard fittings required at site "live cable" LED indicators capacitor voltage dividers mounted on the bushings. Short tiem breaking current-21KA /3Sec,. Making capacity-52.2 Kap, Auxiliary contract-01No+01NC. Rated inslluation Level 75KV. Cable covers-3X, Green (ON)/Red(OFF) push bottons. Note: (a) drawing for panels shall be approved by AO before placement of Order by contractor. (b) The rate for making the foundation/pedestal for RMU of required size, excavation, brick work, concrete shall be included in the quoted rate as per recommendation by the manufacturer.
Supply, installing, testing and commissioning factory made non metalic Junction box made out of themoplastic of size 250x250x160 mm for street light poles with connector for connection incoming and outgoing cables icluding 02x aluminium bus bar strips 150x30x3 mm of size mounting on the insulator and fixing clamp made of FI 25x3 with back strip with suitable nut, bolts and washer including suitable size of double compression cable for incoming and outgoing cables complete all as specified and directed.
M&L for making bore below the road for crossing the pipe for cable protection and fill the putty on both sides of the GI pipe after crossing the armoured cable to avoid the water inside complete all as specified and directed.
Supply, Install , testing and commissioning of LT panel of suitable size for 3 Phase 415 Volts outdoor type, IP 66 protection, suitable for 415 Volts, AC 3 phase, 4 wire, 50Hz made out 3.15 mm thick CRCA sheet of side of the panel board,double door, front and back opening with proper locking arrangement, lifiting lugs, rubber gasket on front and back to make it dust and vermin proof, powder coated including and 300 amp rated copper bus bar, insulated with PVC sleaves and coloured with (red,yellow,blue and black) CTR and internal wiring with suitable size of PVC insulated coper wire, use with angle iron 50X50X6 mm each 750 mm long frame bottom of the CPRI approved panel board, 300 mm grouting in PCC foundation 1:2:4 type C1 20 mm graded stone aggregate and 450mm above GL), thimbling and cable entry boxes with cable gland incl powder coated complete with following (Main panel) :-
Supply, install,testing and commissioning of Eco freindly not less than 82.5 KVA Diesel Engine driven generating set with acoustic enclosure made out of CRCA Sheet powder coated, specially designed lifting arrangement/hooks, meet the latest CPCB , norms of 75 dBA @ 1 mtr distance and as per the testing guide line of CPCB, DG Set shall be conforming to IS:10001/10002 and alternator as per IS: 13364, water cooled type, self starting system with 24 volt DC Supply, 3 phase 4 wire AC 415 volt + 5% at 1500 RPM, 50 Hz, 0.8 PF self excited, self regulated, Automatic voltage regulation, class 'H' insulation type alternator, With AMF (Automatic mains failure) panel for automatic starting at mains failure installed with the all required accessories as per PS
(A) Engine- Adequate capacity of Diesel Engine suitable tonot less than 82.5 KVA based on manufacturer reccomendation , Eco freindly for emission and noise ( CPCB IV NORMS COMPLIANCE) diesel engine confirming to BS/IS standard developing required suitable BHP @ 1500 RPM water cooled complete under NTP condition with a provision for 10 % overload for one hour on 12 hours running complete with standard accessories all as specified and directed (B) Alternator - Standard design alternator rated at not less than 82.5 KVA net output at site after considering derating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self exicited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of + 1% at rated voltage from no load to full load. The alternator shall be confirming to BS 2613 and shall be inposition to generate supply with frequency regulation with in + 1% tolerace. The alternator will be suitable for tropical climate and shall generally confirm to BS - 2613/ IS - 4722 ( C) Auto Main Failure (AMF) : Microprocessore based cubical panel indoor type made out of CRCA sheet of 2mm thick conforming to IS 8623 totally enclosed dust and vermin proof with front and rear openings of 415 Volts, 3 phase, 4 wire, AC 50Hz having copper bus bar capacity required to carry current at 110% load of capacity not less than 82.5 KVA DG set with three phase and half neutral colour coded, prewired with copper cable of suitable size all as standard practice of manufacturer specifications (D) Required accessories & salient features as per OEM instrctuions & as specified.
Supply and fixing LED light fitting 2x16 watt flame proof, CMRI certified recommended for gas/vapor group of IIA & IIIB , Zone 1 and 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connectors etc complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
S&F cable jointing kit for KV grade cable for indoor termination cold shrinkable type joint complete within jointing material and accessories for 3 core XLPE armoured AL Conductor cabel of size 95 sqmm complete all as specified and directed by Engr-in-Charge.
S & F of cable route indicator made out of cast iron and embedded HT cable and size of the cable on the plate of size 80 mm dia 5 mm thick and grouting lugg of suitable size including in PCC foundation of suitable size, complete all as specified and as directed.
Note :- The contract sum shall be arrived after deducting the amount of Schedule as NIL from total quoted amount of BOQ and accordingly lowest bidder shall be ascertained.
Sachdeva Builders (BID ID -3201627)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .