Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAdmitted-Finance | ₹8.9 L | L1 | Admitted-Finance |
| 2 | L2₹10.7 LAdmitted-Finance | ₹10.7 L | L2 | Admitted-Finance |
| 3 | L3₹11.4 LAdmitted-Finance | ₹11.4 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Pritam Electro Mechanical Services L3 | Sachin Electricals L1 | Aziz Traders L2 |
|---|---|---|---|---|---|---|
| 1.00 | M & L for servicing solar water heater (Flat Plate collector/tube collector) by removing the flange plates, cleaning the top glass , collectors internally & externally by using descaling solution, removing the blockages in the collectors complete and refixing the flange plates, recharging the water in recharge tank testing for satisfactory function all as specified and directed. | 90 | Each Job | 1,000 ₹90,000 | 650 ₹58,500 | 400 ₹36,000 Lowest |
| 2.00 | S & F in repair heating element 25mm to 32mm dia, ISI marked for solar water heater of capacity 3 KW all as specified and directed by Engr in charge. | 5 | Each | 400 ₹2,000 Lowest | 1,100 ₹5,500 | 500 ₹2,500 |
| 3.00 | S & F in repair flange plates of size 25 mm dia suitable for flat plate collectors including taking down old unseviceable flange plate all specified and directed. | 5 | Each | 300 ₹1,500 | 500 ₹2,500 | 100 ₹500 Lowest |
| 4.00 | S & F in repair flexible heat resistance rubber pipe (from inter connect plate collector to hot water tank) of size 25 mm to 32 mm dia etc with fixing clamp etc complete all as specified. | 12 | Each | 200 ₹2,400 Lowest | 350 ₹4,200 | 200 ₹2,400 Lowest |
| 5.00 | Taking down the collector from its position, removing the top glass of collector and carry out welding/brazing work to the collector and arresting the leakages in the collector, refixing top glass back with all sealing agent, testing for satisfactory function all as specified and directed. | 4 | Each Job | 400 ₹1,600 Lowest | 3,000 ₹12,000 | 2,000 ₹8,000 |
| 6.00 | M & L for submain wiring with two runs of 4 sq mm single core multi stranded FRLSH PVC insulated and unsheathed copper conductor (red for phase and black for neutral) of grade 1100 volts and including electrical grade PVC casing caping of desired colour not less than 1.2 mm and 25 mm wide & 4 sq mm copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth dolly complete all as specified and as directed including taking down old wiring.
Note :- Three run of 4 Sqmm copper wire and one run of casing caping shall be measured as one length | 300 | RM | 100 ₹30,000 Lowest | 120 ₹36,000 | 100 ₹30,000 Lowest |
| 7.00 | Steam Bath : Checking of electrical wire connection , level sensors, Heaters coil, earthing leakage, electronic circuits, control panel & safety arrangements of the water level & units. Cleaning the sensors, descaling of hard water tank, servicing of electrical, pneumatic valve, proper insulation for the boilers including replacement of defective spares and fixing the same with new including testing one etc complete.
Note -
(a) Contractor has to visit the plant once in a month and carry out comprehensive maintenance as directed by Engr-in-Charge.
(b) During emergency contractor has to visit the plant to rectify the fault without any extra cost to the Govt.
(c) Any spares required during comprehensive maintenance and during emergency repairs shall be measured under respective item as " Supply only". | 9 | Each Job | 250 ₹2,250 Lowest | 2,500 ₹22,500 | 500 ₹4,500 |
| 8.00 | Sauna Bath :- Checking of the heater coil, electronic temp control, calibrating temp device, accuracy, safety cut off the heater & cleaning the sensors of the electronic devices / equipments etc including replacement of defective spares and fixing the same with new including testing etc complete.
Note -
(a) Contractor has to visit the plant once in a month and carry out comprehensive maintenance as directed by Engr-in-Charge.
(b) During emergency contractor has to visit the plant to rectify the fault without any extra cost to the Govt.
(c) Any spares required during comprehensive maintenance and during emergency repairs shall be measured under respective item as " Supply only) | 9 | Each Job | 250 ₹2,250 Lowest | 300 ₹2,700 | 500 ₹4,500 |
| 9.00 | Supply only in repair 15 psi safety valve (Pressure relief valve) | 4 | Each | 300 ₹1,200 Lowest | 850 ₹3,400 | 500 ₹2,000 |
| 10.00 | Supply only in repair 240 V 5 amps glass fuse | 4 | Each | 5 ₹20 Lowest | 320 ₹1,280 | 5 ₹20 Lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
9 Jul 2026, 6:00 pmClosed
Shri Vikas Tanwar, IDSE, GE (CME) Khadki
Garrison Engineer (CME) Khadki, Phugewadi, Dapodi, Pune
REPAIR/MAINTENANCE OF STEAM BATH,SAUNA BATH, GEYSERS, SOLAR WATER HEATER AT CME UNDER GE (CME) KHADKI
2026_MES_771360_1
8710/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer (CME) Khadki, Phugewadi, Dapodi
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer (CME) Khadki
₹40,000
Yes
1 Aug 2026
11 Jun 2026
11 Jul 2026
11 Jun 2026
9 Jul 2026
26 Jun 2026
12 Jun 2026 - 25 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M & L for servicing solar water heater (Flat Plate collector/tube collector) by removing the flange plates, cleaning the top glass , collectors internally & externally by using descaling solution, removing the blockages in the collectors complete and refixing the flange plates, recharging the water in recharge tank testing for satisfactory function all as specified and directed. | 90 | Each Job | 1 | ₹90 |
| 2 | S & F in repair heating element 25mm to 32mm dia, ISI marked for solar water heater of capacity 3 KW all as specified and directed by Engr in charge. | 5 | Each | 2 | ₹10 |
| 3 | S & F in repair flange plates of size 25 mm dia suitable for flat plate collectors including taking down old unseviceable flange plate all specified and directed. | 5 | Each | 3 | ₹15 |
| 4 | S & F in repair flexible heat resistance rubber pipe (from inter connect plate collector to hot water tank) of size 25 mm to 32 mm dia etc with fixing clamp etc complete all as specified. | 12 | Each | 4 | ₹48 |
| 5 | Taking down the collector from its position, removing the top glass of collector and carry out welding/brazing work to the collector and arresting the leakages in the collector, refixing top glass back with all sealing agent, testing for satisfactory function all as specified and directed. | 4 | Each Job | 5 | ₹20 |
| 6 | M & L for submain wiring with two runs of 4 sq mm single core multi stranded FRLSH PVC insulated and unsheathed copper conductor (red for phase and black for neutral) of grade 1100 volts and including electrical grade PVC casing caping of desired colour not less than 1.2 mm and 25 mm wide & 4 sq mm copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth dolly complete all as specified and as directed including taking down old wiring.
Note :- Three run of 4 Sqmm copper wire and one run of casing caping shall be measured as one length | 300 | RM | 6 | ₹1,800 |
| 7 | Steam Bath : Checking of electrical wire connection , level sensors, Heaters coil, earthing leakage, electronic circuits, control panel & safety arrangements of the water level & units. Cleaning the sensors, descaling of hard water tank, servicing of electrical, pneumatic valve, proper insulation for the boilers including replacement of defective spares and fixing the same with new including testing one etc complete.
Note -
(a) Contractor has to visit the plant once in a month and carry out comprehensive maintenance as directed by Engr-in-Charge.
(b) During emergency contractor has to visit the plant to rectify the fault without any extra cost to the Govt.
(c) Any spares required during comprehensive maintenance and during emergency repairs shall be measured under respective item as " Supply only". | 9 | Each Job | 7 | ₹63 |
| 8 | Sauna Bath :- Checking of the heater coil, electronic temp control, calibrating temp device, accuracy, safety cut off the heater & cleaning the sensors of the electronic devices / equipments etc including replacement of defective spares and fixing the same with new including testing etc complete.
Note -
(a) Contractor has to visit the plant once in a month and carry out comprehensive maintenance as directed by Engr-in-Charge.
(b) During emergency contractor has to visit the plant to rectify the fault without any extra cost to the Govt.
(c) Any spares required during comprehensive maintenance and during emergency repairs shall be measured under respective item as " Supply only) | 9 | Each Job | 8 | ₹72 |
| 9 | Supply only in repair 15 psi safety valve (Pressure relief valve) | 4 | Each | 9 | ₹36 |
| 10 | Supply only in repair 240 V 5 amps glass fuse | 4 | Each | 10 | ₹40 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
8710tender.pdf
Tender Documents • 0.74 MB
BOQ_863794.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].