Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.7 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹36.5 L+₹98,702 (2.78%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹37.2 L+₹1.7 L (4.71%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹37.2 L+₹1.7 L (4.80%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest |
| Sl No | Description | Qty | Unit | ESS KAY BUILDER L1 | GEE EMM ASSOCIATES L2 | RAJ KAMAL BUILDERS L4 | Munish Kalia L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified directed by EIC. | 210 | Sqm | 30 ₹6,300 | 28 ₹5,880 | 30 ₹6,300 | 20 ₹4,200 Lowest |
| 2.00 | Material and Labour for coloured non skid/matt finish ceramic tiles, 7 to 8 mm thick, (square/ rectangular), area of each tile exceeding 0.18 sq.m but not exceeding 0.38 sq.m in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer of 15 mm thick cement mortar (1:6) complete all as specified and directed EIC. | 200 | Sqm | 900 ₹1,80,000 Lowest | 900 ₹1,80,000 Lowest | 900 ₹1,80,000 Lowest | 1,000 ₹2,00,000 |
| 3.00 | Ditto all as per item No 2 above but as in dado, riser & skirting over & incl 10mm thick rendering in CM 1:3 complete all as specified directed by EIC | 10 | Sqm | 900 ₹9,000 Lowest | 920 ₹9,200 | 1,000 ₹10,000 | 1,100 ₹11,000 |
| 4.00 | Taking down cement plaster on brick or concrete walls, ceiling etc, including racking out joints , hacking for key, scrubbing down with water etc complete all as specified & directed by EIC . | 1,050 | Sqm | 35 ₹36,750 | 30 ₹31,500 Lowest | 30 ₹31,500 Lowest | 40 ₹42,000 |
| 5.00 | Material and Labour for rendering 5mm thick cement plaster in cement mortar (1:3) on concrete surfaces as in ceiling, finished even and smooth without using extra cement complete all as specified directed by EIC. | 50 | Sqm | 200 ₹10,000 | 220 ₹11,000 | 175 ₹8,750 Lowest | 220 ₹11,000 |
| 6.00 | Material and Labour for rendering 12mm thick cement plaster in cement mortar (1:6) on concrete surfaces as in wall , finished even and smooth without extra cement complete all as specified. | 550 | Sqm | 185 ₹1,01,750 | 230 ₹1,26,500 | 170 ₹93,500 Lowest | 200 ₹1,10,000 |
| 7.00 | Material and Labour 15 mm thick cement plaster in cm 1:4 mixed with liquid water proofing compound @ of 3% as on other than fair face of brick or concrete surface of walls finished surface even and fair all as specified and directed Note : Supply only water proofing liquid shall be measured and paid separately, complete all as specified directed by EIC. | 450 | Sqm | 185 ₹83,250 | 240 ₹1,08,000 | 180 ₹81,000 Lowest | 200 ₹90,000 |
| 8.00 | Supply only liquid water proofing compound to mixed with cement mortar etc, complete all as specified directed by EIC. | 125 | kgs | 40 ₹5,000 Lowest | 50 ₹6,250 | 40 ₹5,000 Lowest | 50 ₹6,250 |
| 9.00 | Material and Labour preparing New plastered surfaces applying two or coats of 100%Premium acrylic emulsion paint having VOC less than 50 Gm/litre and UV resitance as per IS 15489: 2004, Alkali & fungal resisitance , dirt resitance extterior paint of required shade (Company Depot Tinted) withsilidon addiitives @ 1.43 litr/10 Sqm over and including priming coats of exterior priomer applied @ 0.90 litrs/10 Sqm over new surfaces all as specified | 450 | Sqm | 60 ₹27,000 | 95 ₹42,750 | 45 ₹20,250 Lowest | 90 ₹40,500 |
| 10.00 | Material and Labour preparing old plastered surfaces applying two or coats of 100%Premium acrylic emulsion paint having VOC less than 50 Gm/litre and UV resitance as per IS 15489: 2004, Alkali & fungal resisitance , dirt resitance extterior paint of required shade (Company Depot Tinted) withsilidon addiitives @ 1.43 litr/10 Sqm over and including priming coats of exterior priomer applied @ 0.90 litrs/10 Sqm over new surfaces all as specified | 350 | Sqm | 60 ₹21,000 | 95 ₹33,250 | 50 ₹17,500 Lowest | 90 ₹31,500 |
Tender Value
₹46.4 L
EMD Value
₹92,780
Closing Date
4 Oct 2025, 6:00 pmClosed
GE Amritsar
GARRISON ENGINEER AMRITSAR CANTT PIN 143001
SPL REPAIR NO 62 (ADM BLOCK) OF 163 FD REGT AND SPL REPAIR TO BLDG NO P-1A (OFFRS MESS GUEST ROOM) ROOF TREATMENT OF 270 ENGR REGT AT OLD AMRITSAR CANTT
2025_MES_729619_1
GE/ASR-60/2025-26
Open Tender
Civil Works
Works
180 days
GE Amritsar
CLASS D CATEGORY a i
8 documents required · 8 mandatory
₹500
GE Amritsar
₹92,780
1 Jan 2026
6 Sept 2025
11 Oct 2025
6 Sept 2025
4 Oct 2025
20 Sept 2025
6 Sept 2025 - 13 Sept 2025
Amount
Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified directed by EIC.
Material and Labour for coloured non skid/matt finish ceramic tiles, 7 to 8 mm thick, (square/ rectangular), area of each tile exceeding 0.18 sq.m but not exceeding 0.38 sq.m in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer of 15 mm thick cement mortar (1:6) complete all as specified and directed EIC.
Ditto all as per item No 2 above but as in dado, riser & skirting over & incl 10mm thick rendering in CM 1:3 complete all as specified directed by EIC
Taking down cement plaster on brick or concrete walls, ceiling etc, including racking out joints , hacking for key, scrubbing down with water etc complete all as specified & directed by EIC .
Material and Labour for rendering 5mm thick cement plaster in cement mortar (1:3) on concrete surfaces as in ceiling, finished even and smooth without using extra cement complete all as specified directed by EIC.
Material and Labour for rendering 12mm thick cement plaster in cement mortar (1:6) on concrete surfaces as in wall , finished even and smooth without extra cement complete all as specified.
Material and Labour 15 mm thick cement plaster in cm 1:4 mixed with liquid water proofing compound @ of 3% as on other than fair face of brick or concrete surface of walls finished surface even and fair all as specified and directed Note : Supply only water proofing liquid shall be measured and paid separately, complete all as specified directed by EIC.
Supply only liquid water proofing compound to mixed with cement mortar etc, complete all as specified directed by EIC.
Material and Labour preparing New plastered surfaces applying two or coats of 100%Premium acrylic emulsion paint having VOC less than 50 Gm/litre and UV resitance as per IS 15489: 2004, Alkali & fungal resisitance , dirt resitance extterior paint of required shade (Company Depot Tinted) withsilidon addiitives @ 1.43 litr/10 Sqm over and including priming coats of exterior priomer applied @ 0.90 litrs/10 Sqm over new surfaces all as specified
Material and Labour preparing old plastered surfaces applying two or coats of 100%Premium acrylic emulsion paint having VOC less than 50 Gm/litre and UV resitance as per IS 15489: 2004, Alkali & fungal resisitance , dirt resitance extterior paint of required shade (Company Depot Tinted) withsilidon addiitives @ 1.43 litr/10 Sqm over and including priming coats of exterior priomer applied @ 0.90 litrs/10 Sqm over new surfaces all as specified
Material and Labour preparing New plastered surfaces on walls one coat of primer paint, and applying two coat of oil bound distemper with 1 mm wall care putty complete all as specified directed by EIC. (Interior)
Material and Labour preparing Old plastered surfaces comlete removal of existing treatment on walls one coat of primer paint, and applying two coat of oil bound distemper, complete all as specified directed by EIC. (Interior)
Material and Labour for preparation of new plastered ceiling surfaces one coat of primer paint and applying two coats of white wash complete all as specified and directed by EIC.
Material and Labour for preparation of Old plastered surfaces complete removal of existing treatment on Ceiling one coat of primer paint surfaces and applying two coats of white wash complete all as specified and directed by EIC.
Demolition of brick work built in cement mortar incl all quoins, arches, pillars etc, complete all as specified and directed by EIC.
Material and Labour Brick work with sub class "B" bricks, straight or curved on plan exc 6 m mean radius , built in CM 1:6 complete all as specified and directed .
Dismantling of brick tiles or terracing tiles single layer on roof complete all as specified and directed by EIC
Demolition of Mud in roof any thick ness including plastering and leeping (Whether full thickness removed or only a part therof), complete all as specified directed by EIC.
Material and Labour for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) mixed with water proofing liquid as in padding, in roof kerb to amintain slop correction of the depressed undraution portion complete all as specified and as directed
Material and Labour for applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/Sqm including cleaning surfaces etc ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric( weight not less than 150 gms/sqm) laid on primed surface by forced application with and including approved bitumen primer as per manufacturer's instructuctions including cleaning the surfaces complete all as specified and as directed. Note: Sheet shall be five layered prefabricated Atactic Polypropyleen Polymer (APP) modified 3 mm thick membrane (weighing not less than 3 kg/sqm) reinforced with 150 gsm polyester non- woven fabric. Concrete of roof surface shall be scratched with scratched tool before finishing roof surface when the concrete surface is still green,10mm thick 1:4 cement plaster shall be laid .The roof surfaces shall be throughly wire brushed, washed, dried up and cleaned to all foreign matter and dust prior to the appliction of primer. On the dried surface one coat of approved bituminous primer, having density in the range of 0.87 to 0.89 kg/litre at 25 degree centigrade and viscosity of 40 to 160 CPS, manufactured by same manufacturer @ 0.4 litre / sqm shall be applied. APP membrane shall be laid on primed surface by torch application method after allowing 24 hours for primer to dry . Laying off APP membrane will normally be laid in length at right angle to the direction of slope. The overlaps shall be of minimum 100mm on longitudinal direction and 150 mm on the transverse direction. All overlaps shall be bonded with bitumen primer and levelled by heating the overlaps with butane torch. the treatment shall be done by the approved authorised applicatiors.
Material and Labour for 40mm thick brick tiles laid on concrete roof padding over and including 15 mm thick cement screed bed in CM (1:6) using grey cement, jointed and grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all specified and as directed.
Material and Labour for 40mm thick brick tiles (EXCEPT TILES) laid on concrete roof padding over and including 15 mm thick cement screed bed in CM (1:6) using grey cement, jointed and grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all specified and as directed.
Material and Labour for roughening old surface of concrete roof/floor etc by picking, sweeping and washing down with water to remove dust/dirt and brusing neat cement slurry with 3.0 Kgs per Sqm complete all specified and as directed.
Taking down Chowkats or frames from the opening of size not exceeding 1.5 sqm each with shutters ( without taking off shutters from the frames) complete all as specified and directed (Windows)
All as per Srl item herein above, but size of opening exceeding 1.5 Sqm but not exceeding 4 Sqm
Supply and fixing Factory made steel window/ventilator box type, primer coated , comprising made out of ERW Hollow 'P' section of size 6mm x 25mm of wall thickness frame 1.25mm single rebated frame and comprising glazed and skelton shutter made of ERW sec 50mmx20mm with 1mm thick wall thickness and operated leaf side top hung divided in three panel by flat iron suitable size complete welded to frame of shutter and openable shutter prepared to receive wire gauze including provision of flat iron riveted bolt to secure wire mesh, complete including cuttisng holes four nos for each window for hold fast and PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in hold fast size of PCC 150x230x75mm (04 Nos in each window) including necesssary form work complete and including following fittings welded to frame/shutter :- (a) Hold fast 150mm long 25mm x 6mm iron made to shape - 02 Nos in each window (02 Nos each side). (b) Handle of 'Z' section 20mmx25mm, 100mm stopper - 01 No in each leaf (c) MS tower bold 150mm long - 02 Nos in each leaf. (d) Cleat 55mm long of hollow square 15x15x24mm welded to hingesgauze wall thickness welded to hings of 50mm size - 01 No per leaf. (e) MS Box type hinges of size 75x12mm - 03 Nos per leaf. (f) Fabrication & Fixing complete. NOTE :- (i) Glass panes and painting shall be measured & paid separately under respective items. (ii) Design shall be got approved from the Engineer-in-Charge as per Drg No CELZ/TD-1020/08 Sh NO 1/3 to 3/3 before fabrication and bulk order to the manufacturer.
Supply and fixing Presed steel frames for doors Size of frame 105 x 60 mm with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete as specified supplied and fixed EIC.
Supply and fixing 30 mm thick Flush shutters , solid core construction , with block board core and covered with 0.50 mm thick laminate on both side wood grain texture with lipping to match, complete all as specified and directed by EIC.
Supply and fixing 100mm Extruded aluminium alloy handles, fabricated type, anodised, complete all as specified directed by EIC.
Supply and fixing 150mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed, complete all as specified directed by EIC.
Supply and fixing fixed in repair 250 mm Aluminium alloy, anodised, sliding door bolts with hasp and stapple(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified directed by EIC.
Supply and fixing fixed in repair Aluminium (extruded Section body) door closer hydrau lically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed, complete all as specified directed by EIC.
Supply and fixing 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor and fixed,complete all as specified directed by EIC.
Material and Labour for preparation of New steel surface of any description not other wise described, over 10cm width or girth and applying two coats of synthetic enamel paint, complete all as specified directed by EIC.
Material and Labour for painting to New wooden surface of any description not other wise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer on ply wood including preparation of surfaces etc,complete all as specified directed by EIC.
Material and Labour two coats of synthetic enamel painting on wooden surfaces of any description over 10 cm in width or girth not otherwise described above pink primer including prepration of previously untreated surfaces.
Supply and fixing in repair 4mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, incl hacking out complete all as specified directed by EIC.
Supply and fixing fixed in repair Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples , complete all as specified directed by EIC.
Supply and fixing Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box,main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed make-Godrej
Supply and fixing Anodised aluminium frame for doors powder coated (minimum thickness of powder coating shall not be less than 50 micron),windows,ventilators,side hunge one or more rebates including necessary jointing cleats,glazing clips complete all as specified and directed
Supply and fixing Anodised aluminium door shutters powder coated (minimum thickness of powder coating shall not be less than 50 micron), aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified Note : Each panel shall be measured separetely. Glass pane shall be measured and paid separetely.
Supply and fixing Providing and fixing powder coated(Min thickness of powder coating shall be 50 micron) aluminum windows shutter of size min 18mmx50mm for sliding type windows of standard tubular sections of approved make having glazed panels or glazed and gauzed panels of appropriate size running on seperate tracks in the channel conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth,rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. All the panels shall be of appropriate size having overlaps as required and including all required beadings, clips, rollers, rubber gaskets, cleats,complete and powder coating in approved shade and colour. Note:- Each panel shall be measured separetely. Glass pane and wire mesh shall be measured and paid separetely.
Supply and fixing Anodised aluminium grill (anodised transparent or dyed to required shade according to IS:1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with CP brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixinf approved anodised aluminium standard section around the opening, all complete as per requirements and direction of Engr-in-charge.
Supply and fixing Sheet glass, 5.5mm thick ordinary quality, in squares,exceeding 0.50 sqm in each pane including rubber packing and aluminium beading ,as per instructions of manufacturer scomplete all as specified and directed
Supply and fixing toughned glass, 10 mm thick as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required. all as specified and directed
Supply and fixing Brass mortice lock,4 levers, verticle type, size 100 mm, complete all as specified and directed.
Disconnecting existing tank capcity 500 ltrs setting aside (or lowering if required ) for repair , cleaining, etc and hosting if required reconnecting and re-fixing in postion. (Cleaning and removing all scale and dirty etc from tanks and from mouths of circulating pipes etc etc, complete all as specified and directed by EIC.
Material and Labour 75 mm thick, plain cement concrete 1:3:6, type C-1 using 20 mm graded mechaically crused stone aggregates, laid in 1:20 slop as in Plinth protection/paving/shafts including making joints at 3.00 mtrs intervals and at each corner, the joint shall be filled with mastic filling to full depth) comprising of one partheated hot below bitumen 85/25, two parts heated sand (by volume), surface fininshed even and smoot witout using extra cement complete all as specified. Note : The concrete shall be laid at a strech not exceeding 3 mtr in legth and width of joint shall not more than 12mm.
Supply and fixing 110 mm PVC (SWR) pipe single socket in any length with rubber ring joints fixed in walls,complete all as specified directed by EIC.
Supply and fixing for 110 mm PVC (SWR) bend any radius joints fixed in walls, complete all as specified directed by EIC.
Disconnecting existing tanks 1000ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc
Disconnecting existing tanks 500ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc
Material and Labour Preparing old plastered surfaces of wall and applying two coats of cement base paint of approved shade/tint complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials and making good disturbed surfaces of walls, floors, etc.complete all as directedNOTE: Cost of unserviceable materials will be charged from the contractor against Schedule of Credit.
Taking down carefully existing serviceable Ceiling fan/Wall mounted fan, ceiling cable,exhaust fan, ceiling end, etc., removing the fan for keeping in safe custody, hanging the ceiling fan with down rod including clamps, hooks, holdfasteners etc and connecting up, including making electric connection from ceiling rose or connector to fan complete all as directed
Material and Labour for point wiring complete with 1.5 sqmm single core PVC insulated sheathed multi-stranded, copper conductor FRLS grade cable of 1100 volts grade conforming to IS:694 drawn through existing metallic/rigid PVC concealed conduit, medium grade, ISI marked, not less than 20mm bore with conduit accessories concealed on wall and ceiling/roof etc, with provn for fixing modular metal flush boxes not less than 1.0 mm thick of suitable modules, concealed in walls with modular white plated cover as top cover fixed with screws for housing switches, socket outlets, fan regulators etc, including provn of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, sheathed, 1100 volt grade,multistranded single core green colour copper conductor for earth continuity connected to earth dolly complete all as directed
(a) Fan point/ exhaust fan point / one light point / bell/ buzzer controlled by one switch/ bell push.
(b) One socket outet point 5 amps on the same board.
(c) One socket outet point 5 amps on the independent board.
All as Ser item 3 here in before but with 2.5 sq mm wire and earth wire of 2.5 sq mm for 3 Pin 15 Amp modular type socket outlet.
Material and Labour for point wiring complete with 1.5 sqmm single core PVC insulated sheathed multi-stranded, copper conductor FRLS grade cable of 1100 volts grade conforming to IS:694 drawn through and including non metalic rigid new PVC conduit, medium grade, ISI marked, not less than 20mm bore with conduit accessories concealed on wall and ceiling/roof etc, with provn for fixing modular metal flush boxes not less than 1.0 mm thick of suitable modules, concealed in walls with modular white plated cover as top cover fixed with screws for housing switches, socket outlets, fan regulators etc, including provn of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, sheathed, 1100 volt grade,multistranded single core green colour copper conductor for earth continuity connected to earth dolly complete all as directed
(a) One light point/Bell/Fan point controlled by one switch.
(b) One 3 pin 5 Amps socket outlet on independent board.
(c) One 5 Amps outlet point on same board with other switches/sockets
All as per ser item No 5 here in above but point wiring with 2.5 Sqmm FRLS cable and 2.5 sqmm cable earth continuity wire for one 3 pin socket outlet,15 Amps on independent board.(i) The wiring shall be done in proper colour coding using red, yellow and blue for phase, black for nuetral and green for earth wire.(ii) Modular metal flush boxes concealed in wall with suitable cover plate for mounting switch, sockets, regulator etc. and cost of cutting chases & making good as existing to disturbed surface with cement mortar, if required any shall be deemed to included in the quoted rates.(iii) Modular fittings/fixtures such as switch, socket, regulator, etc., shall be measured and paid separately as under relevant item.
Supply and fixing modular switch 1 way 6A, 240 volts, 1 module complete all as specified and directed
Supply and fixing modular socket, 6A, 240 volts, 2/3 pin combined 2 module, flush type all as specified and directed
Supply and fixing modular switch 1 way 16A, 240 volts, 1 module complete all as specified and directed
Supply and fixing modular socket, 6A/16A, 240 volts, 2/3 pin combined 2 module flush type all as specified and directed
Supply and fixing modular fan step regulator, 2 module, 240 Volts, 50 Hz, suitable for ceiling fan all as directed
Supply and fixing ceiling rose surface PVC/Polycarbonate, isolated body with face Bakelite 65 x 50 mm three terminal, 240 volts, AC single phase complete all as specified
Supply and fixing steel metal enclosure single pole & neutral with a 2 pin and earth plug and socket complete with one single pole MCB SP 20 Amp, 240 volts complete all as specified and directed.
Supply and fixing LED lights fitting 1x 20W, 220V, AC, 6500K, decorative box type with driver, double sided connection, LED tube light connecting up with 3 core flexible copper conductor cable (1.0 mm² size/core) from ceiling rose complete all as specified and directed.
Supply and fixing PLUTO NEO LED luminaire 600mm x 600mm, 2X2 36/40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Supply and fixing Air fresh fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, single phase, 1200 RPM, Copper winding of sweep 300 mm complete fixed/grouted to wall with suitable bolts, nuts etc., and connecting up with & including 3 core flexible copper conductor cable (1.0 mm² size/core) from ceiling rose to exhaust fan and writing MES No. including cutting hole suitable for fixing exhaust fan complete all as specified and directed
Supply and fixing lamp holder, PVC / polycarbonate type insulated body with back plate suitable for batten / angle fittings complete all as specified and directed.
Material and Labour for distribution board, vertical, made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, double door, VTPN 4 way , 3 phase , 415 volts grade with insulated rated bus bar assembly with isolated neutral bar,door earthing, earth bar IP- 43 protection with poly urithene (PU) gasketing, IK-08 Mechanical impact resistance, door earthing flush to wall, including testing suitable for fixing MCCB, MCB TPN/TP/SPN/SP etc, including dismantling of old UNSV one of any type/size from site and making good to disturbe surface wall complete all as directed (1.) MCCB 100 Amps , 25 KA, TP 415 Volts
Material and Labour for distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, double door, SPN 12 way, 240 volts grade with 200 Amps insulated rated bus bar with nickel plated brass, isolated neutral bar and door earthing, earth bar IP- 43 protection with poly urithene (PU) gasketing, IK-08 Mechanical impact resistance, flush to wall, including testing suitable for fixing MCB SPN, SP etc, including dismantling of old UNSV one of any size/type from site and making good to disturbe surface wall complete all as directed NOTE: Necessary blank plates if required any to cover the blank MCB's place in DB and the rate shall be deemed to included in the quoted rates.
Supply and fixing MCB of SP 5 to 32 Amps current carrying capacity, 240 V, 10KA 'C' curve fixed in the MCB DB complete with connection testing & commissioning complete all as directed
All as per ser item No. 20 above but for MCB SPN 40 to 63 Amps, 415 V grade
Supply and fixing Dusk & dawn roadway luminaries 45 Watt, 230 V AC, 5700K outdoor type with epoxy black powder coated sheet, high pressure die-cast aluminum hosing and heat resistant complete with impact and corrosion resistant including thermal management in multiple optics, PF>95%, THD<10%, Lumen>4500 lm with IP 65/66 protection complete incl connecting wire with flexible PVC insulated copper cables from ceiling rose to fitting including driver, lamp bracket made of 32mm bore galvanised iron light grade pipe made to shape having overall length not exceeding 1.5 mtr, through mild steel clamp of 25mm width and four Nos. nuts, bolts & washers of 12mm dia, 100mm long fixed to wall with all other fittings complete and testing all as specified and directed.
Supply and fixing in replacement, Sub main wiring with two single pole 6 sqmm (nominal area) stranded copper conductor FRLS PVC insulated and unsheathed cable drawn in and including non metalic PVC rigid conduit medium grade of suitable size with all standared fitting, on surface including one run of continuous PVC insulated standed copper conductor PVC insulated stranded copper conductor FRLS cable 6 sqmm (nominal area for earth continuty, including taking out and removal of old sub main wiring, complete all as specified and directed Note:- 1 Two runs of 6 sqmm main cable one run of 6 sqmm for earth cable & conduit shall be measured as one unit one running meter.
Supply and fixing in replacement, Sub main wiring with two single pole 4 sqmm (nominal area) stranded copper conductor FRLS PVC insulated and unsheathed cable drawn in and including non metalic PVC rigid conduit medium grade of suitable size with all standared fitting, on surface including one run of continuous PVC insulated standed copper conductor PVC insulated stranded copper conductor FRLS cable 4 sqmm (nominal area for earth continuty, including taking out and removal of old sub main wiring, complete all as specified and directed Note:- 1 Two runs of 4 sqmm main cable one run of 4 sqmm for earth cable & conduit shall be measured as one unit one running meter.
Material & Labour in replacement Earthing complete with galvanized steel earth plate electrods of size 60cmx60cmx6mm thick burried directly in ground vertically(earth pit not less than 2.25 mr deep below normal ground level) with top edge of the plate not less than 1.5 mr below normal ground level connected to galvanized iron or steel earth wire 4 mm dia by means of bolts nuts check nuts and Gl washers of Galvanised iron protected by steel pipe 15mm (light grade) all as shown in elecrrical plate No.3 of SSR Part-l and connecting to earthing test point (earth test point to be provided at 5 mtr distance from earth pit) and testing on completion including necessary excavation and earth work. The rate also include charcoal dust and salt in alternate layers 25 mm dia light grade Gl pipe, funnel, wire mesh. Concrete 1:3:6 type C-1 for pit and RCC pit cover. The extra cost of the water- ing pipe,bends, elbows shall be included in the unit rate. Note: RCC pit cover shall be precast of RCC 1:2:4type B-1 80mm thick reinforced with XPM weighing not less than 4 Kg/Sqm.
Supply and fixing ceiling fan 1200mm sweep complete with blades, down rod as per site requirement, electronic regulator & accessories (i.e. PVC canopy, rubber bush, split pin, hanging clamp, hold fasteners etc.) 230 Volts, white colour, with min air delivery 210 CFM, BEE 5 star rated with brushless direct current motor (BLDC) technology and connecting up with & including 3 core flexible copper conductor cable (1.0 mm² size/core) from ceiling rose to ceiling fan and complete all as specified and directed.
GEE EMM ASSOCIATES (BID ID -3439841)
Munish Kalia (BID ID -3442770)
RAJ KAMAL BUILDERS (BID ID -3442113)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .