| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹27.6 L+₹49,732.50 (1.83%)Rejected-Finance H NO 02 SAGAR ROAD OPPO MKD GIRLS SCHOOL TILAK NAGAR BIKANER 334001 | BIKANER | BIKANER | RAJASTHAN | 334001 | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹28.2 L+₹1.1 L (4.09%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
28 Oct 2019, 6:00 pmClosed
GE (N) Bikaner
GE (N) Bikaner Mil Stn Bikaner
Repair to Ceiling plaster, Chajjas, Plinth Protection, Grouting, Water proofing treatment and other misc work of under AGE B/R I of GE(North) Bikaner..
2019_MES_279290_2
GE (N) BKN/Token-42/19-20
Open Tender
Civil Works
Item Rate
330 days
GE (N) Bikaner
Class D category a (i)
8 documents required · 8 mandatory
₹500
GE (N) Bikaner
₹60,000
Yes
17 Mar 2020
19 Oct 2019
30 Oct 2019
19 Oct 2019
28 Oct 2019
21 Oct 2019
Amount
Demoliton of brick work built in cement mortar including all quions arches pillars etc
Demolition of cement conc. Reinforced as in roof slab , beams, chhajas and similar suspended work reinforcement cut as required to facilitate demolition.
Demolition of spalling concrete from soffits of slab to any thickness in controlled manner incl cleaning of reinforcement as directed and approved by Eng-in-Charge.
Demolition of cement conc. In ground floor and paving not exc. 15cm thickness (below or above GL)
Dismantling timer scantling over 40 sqcm in section in any position.
Dismantling wrought iron or mild steel work of any description as in girders etc
Dismantling of Roof tiles of any description or thickness in floor, apron etc laid, bedded and pointed in cement mortar complete all as specified and as directed by Engineer-in-Charge.
Demolition of lime concrete of any description over roof slab complete all as specified and as directed by Engineer-in-Charge..
Dimantling pipes of any desc.fixed to wall or laid under floor
Taking down cement plaster on brick or stone walls incl. raking out joints hacking for key scrubbing down with water etc.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position incl cleaning if reqd.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position incl cleaning if reqd.
Taking down or up, 15 mm bore galvanised steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed by Engineer -in-charge.
Taking down or up, 20 mm bore galvanised steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed by Engineer -in-charge.
Refixing 15 mm bore old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.)
Refixing 20 mm bore old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.)
GI tubing medium grade with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 15mm complete all as specified and directed by Engineer-in-charge.
GI tubing medium grade with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 20mm complete all as specified.
Cutting chases,pinning in making good to facing where requried and pointing in cement mortar 1:3 to ends or edge of landings, steps, cills,sunshade,shelves, lintel etc. tubes or concealed conduit etc. and making good, cutting not exc 10 cm girth
Raking out joints/pointing to brick work or stone patti ceiling laid flat in lime concrete complete
PCC 1:2:4 Type B1 as in mass conc or bedding layer to provide levelling course of varying thickness as reqd at site .
Brick work with sub class B bricks Fly Ash straight or curved on plan exc 6m mean radius brick walls built in CM 1:4.
TMT bars 10mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with Mild Steel wire (annealed) not less than 0.9mm dia complete all as specified.
TMT bar 6mm to 8mm dia for reinforcement.
Reinforced cement concrete 1:2:4 type B-1 ( using 20 mm graded cdrushed stone aggregate) as in chajjas,parapets and the like, all as specified and directed by Engr-in-Charge. (Note : Contractor shall shall have no claim on height , form work reqd )
Formwork to chullah hoods, chajjas, troughs and similar items including edges
75 mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in plinth protection laid to slope of 1 in 12 and finishing cement concrete surface even and smooth without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering of exposed edges where directed and providing 6 mm thick joints through the thickness of plinth protection duly filled with mastic filling of one part of hot bitumen 85/25 grade and three parts of fine sand (all by weight) complete.
Joist, channel , angles or tee sections fixed independentely , without connecting plates , etc cut in ordinary length all as specified and directed by Engineer- in -charge
PVC(SWR)single socketed in any length with rubber ring joint fixed with wall of 110mm as in rain water pipe
PVC(SWR) bends any radius 110mm.
Rendering 15mm thick cement plaster on fair faces of brick or conc. Surfaces in cement mortar 1:4,even and smooth w/o using extra cement ,incl mixing of water proofing compound .(Note WPC shall be measured and paid for seperately)
Rendering 15mm thick cement plaster on fair faces of brick or conc. Surfaces in cement mortar 1:6,even and smooth w/o using extra cement .
Rendering 5mm thick cement plaster on concrete surfaces in ceiling in CM 1:3 finished even and smooth.
PCC 1:2:4 Type B0 (12.5 mm graded aggregate as in coloumns , bed plates,mud stops , copings, kerbs incl weathering , slightly rounded or chamfered angles etc
Roughing surfaces of old conc surfaces by picking up , sweeping,cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @3kg/Sqm including 15 mm thickscreeding in CM (1:4) finished even and smooth mixed with water proofing compound (WPC shall be measured and paid separatley)
M&L applying injuction grouting with nozzle on slab. The mortal can be applied from a minimum of 15mm to 40mm thickness in smaller vertical pockets and upto 25mm thickness in horizontal applications. The Mortal should have a minimum compressive strength 12N/mm2 in 1 Day and 45N/mm2 in 28 days , minimum flexural strength should be 8N/mm2 in 28 days. (Sikkon/Dr Fixit/Fosroc).
Repair of cracks, corner with cement mixed with water proofing compound in the ratio of 1:1. Water proofing compound . (Dr Fixit URP - 301)/Sikka/Forsoc)
Applying two coats pidifin coat including mixing of liquid agent and dry powder . (Pidifin 2K no 112 ) on wall.( Dr Fixit /Sikka)
Supply only water proofing compound, ISI marked, complete all as specified and as directed by Engineer-in-Charge.
Heavy Duty reinforced acrylic coating for terrace/walls water proofing (Make Dr Fix It ,Asian,Sikka) over a coat of Primmer for Sealer coat (Dr fix it) with roller as directed and app by Eng-in-Charge.
S&F self adhesive membrane 1.5mm thick self adhesive elastomeric SBS (Styrene Butadiene Styrene) bitumen based membrane with high density aluminum film on top ,provded with Pibial / Emufal TE Bitumen primmer @0.3 ltr per sqm , mimimum over laps shall be 50mm on sides and 100 mm on end laps as directed by Eng-in-charge. Make : Sika or Equalvalent as approved by GE.
M&L for polythene film black 150micron
Applying evenly a tack coat of industrial bitumen 85/25 ,1.2kg/sqm incl cleaning surface.
Lime concrete terracing as specified on roof
40 mm thick Brick tiles bedded in 15 mm thick cement and sand mortar (1:6) and joints grouted flush in cement and sand mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and as directed by Engineer-in-Charge.
Apply one coat of “Dr Fixit Rust Remover” (Rust removing chemical) or “Defroster” or equivalent chemical as approved to old rusted reinforcement after necessary preparation of surfaces by brush application
Supply and fix hard drawn steel wire fabric cut to length bent to shape, fabric 3 mm dia, 50 mm mesh cover entire steel surface not exc. 4 kg per sqm
Bonding the entire exposed surface with one coat of “Fosroc Ntobond SBR” as per manufacture instruction
Apply one layer of Fosroc spray ser SL concrete 25 mm to 35 mm thick (comprises composition 1:2:1 plain cement concrete i.e. one part of cement two parts of fine aggregate and one part of 10 mm and down size trap stone aggregate) mixed with spray set SL 2 to 2.5% weight of cement and 12.5 to 16.5 liters of water mixed as per manufacture instructions and gunniting pressure nozzle with a delivery capacity of 2.5 kg per sq m over column, beam, roof slab and other similar work . Note . (a) The extra filling of concrete in holes in occured due to spalling of concrete after demolition shall be rectified by contractor without any extra cost. (b) The site shall be handed over to the contractor in parts of any size area. The work executed at site shall be duly floated and made smooth & even clerance from wall or site and any damage in sole responsbility of contractor without any extra cost to govt.
10 mm thick rendering in cement mortar 1:4 over gunniting / concrete surface and finished the surfaces even and smooth without using extra cement.
40-50mm thick sand stone slab not exc 2mtr in length, punched dressed self faced set and pointed in CM 1:4 as in plinth protection and chajjas complete ass as directed
Framed work such as grills, framed guard bars barred iron doors, ladders framed balusters railing and similar works confirming to FE 410-0 0r Fe 310-0
Flush pointing in cement mortar 1:3 on ceiling surfaces of stone patti roofs complete
Preparation of newly plastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over a coat of chalk whiting complete all as specified and as directed by Engineer-in-Charge.
M&L for applying coat of oil bound distamper on old decorated surfaces of desired finish as app by Eng-in-charge in any position
Preparation of newly plastered surfaces of wall and applying two coats of cement based complete all as specified and directed by Engineer-in-charge.
M&L for one coat cement base paint on old plastered or un plastered surfaces including preparation of surfaces.
Preparing surfaces of plaster or unplaster new and applying three coat of white wash on ceiling
Prerparing old decorated surfaces plastered/unplastered by brooming down etc and applying one coat of white wash on ceiling complete all as specified.
M&L preparation of new steel surfaces and applying two coats of synthetical enamel paid over a coat of red oxide.
Complete removal of white wash of old plastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over a coat of chalk whiting and one coat of wall care putty complete all as specified and as directed by Engineer-in-Charge.
Complete removal of existing treatment of walls and applying two coat of cement base paint (Ist quality) in plain pattern on walls and over a coat of alkali resistant priming paint complete all as specified.
S&F self drilling and anchoring bolt for strengthening and holding of reinforcement steel size 10mm dia and 60 mm long
SHREE GURU NANAK CONSTRUCTION COMPANY
M/S BIKANER CHEMICAL LABORATORIES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .