SE OMC-V ATPS Anpara
office of SE OMC-V ATPS Anpara
Maintenance of 6.6 KV, 0.4 KV motors and rewinding of 0.4 KV motors and maintenance of 6.6 KV Jyoti make Breakers, Power Transformers, 0.4 KV Modules. MCC and Electrical Panels installed in CHP, 3X210MW, ATPS, Anpara
2022_RVUNL_694907_1
03/CHD-II/ATPS/2022-23
Open Tender
Electrical Works
Fixed-rate
365 days
office of SE OMC-V ATPS Anpara
as per PQC
3 documents required · 3 mandatory
₹1,180
Dy CAO CFA and BO ATPS Anpara
₹44,890
6 Sept 2023
30 Apr 2022
14 Jun 2022
30 Apr 2022
13 Jun 2022
30 Apr 2022
Amount
Maintenance of 6.6 KV and 0.4 KV motors and rewinding of 0.4 KV motors installed in CHP RATE SCHEDULE PART-A (6.6KV motor maintenance) Bearing replacement
Upto 280 KW
Above 280 KW up to 400 KW
Above 400 KW up to 800 KW
Bearing revisioning with change of lubricnt and cleaning.
Upto 280 KW
Above 280 KW up to 400 KW
Above 400 KW up to 800 KW
Removal of damaged motor from foundation after decoupling and cable disconnnection etc.
Upto 280 KW
Above 280 KW up to 400 KW
Above 400 KW up to 800 KW
Greasing of bearings.
Upto 280 KW
Above 280 KW up to 400 KW
Above 400 KW up to 800 KW
Re-erection of new motor after revisioning dry out and test.
Upto 280 KW
Above 280 KW up to 400 KW
Above 400 KW up to 800 KW
Overhauling of motor
Upto 280 KW
Above 280 KW up to 400 KW
Above 400 KW up to 800 KW
Dry out of motor
Upto 280 KW
Above 280 KW up to 400 KW
Above 400 KW up to 800 KW
In application of insulating on stator wedge,tighting and adustment etc.
Upto 280 KW
Above 280 KW up to 400 KW
Above 400 KW up to 800 KW
Revisioning of cooling/fans tighting
Upto 280 KW
Above 280 KW up to 400 KW
Above 400 KW up to 800 KW
Cleaning of heat exchanger.
Upto 280 KW
Above 280 KW up to 400 KW
Above 400 KW up to 800 KW
Cable box/ terminal box repair, change of insulator/leads etc.
Upto 280 KW
Above 280 KW up to 400 KW
Above 400 KW up to 800 KW
Space heater repair/replacement work.
Upto 280 KW
Above 280 KW up to 400 KW
Above 400 KW up to 800 KW
Dismantling of damaged motor for removal of motor
Upto 280 KW
Above 280 KW up to 400 KW
Above 400 KW up to 800 KW
Modification of base frame tralley for 6.6 KV motor & gearbox.
Re-assembly of dismantled motor
Upto 280 KW
Above 280 KW up to 400 KW
Above 400 KW up to 800 KW
Trasportion from store to site or place to place or vice-versa.
Upto 280 KW
Above 280 KW up to 400 KW
Above 400 KW up to 800 KW
Dismantling and assembling of heat exchanger of motor
Upto 280 KW
Above 280 KW up to 400 KW
Above 400 KW up to 800 KW
Repair of cracked rotor bars.
Upto 280 KW
Above 280 KW up to 400 KW
Above 400 KW up to 800 KW
RATE SCHEDULE PART-B (i) Overhauling of motors and DC Generators as and when required.
Upto 1 Kw
Above 1 KW upto 5 KW
Above 5 KW upto 15 KW
Above 15 KW upto 25 KW
Above 25 KW upto 175 KW (Rate is to be quoted in Rs/ KW)
Replacement of Motors/ DC Generators
Upto 1 Kw
Above 1 KW upto 5 KW
Above 5 KW upto 15 KW
Above 15 KW upto 25 KW
Above 25 KW upto 175 KW (Rate is to be quoted in Rs/ KW)
Overhauling of Roof ventilation fan at 37 mtr level
Bus bar tightness at site of S/R machine No. II. Dust extraction, Dust suppression
RATE SCHEDULE B (ii) Tightening of connection plates of 6.6 KV and 0.4KV motor (min 140 Nos. of Motors)
Servicing of Control Panels,LCCs,JBs. (min 50 Nos.)
Greasing of 0.4KV motors
Rate SCHEDULE PART- C (0.4KV motor rewinding) Rewinding of tripping / closing coil of 220V DC for 6.6 KV Jyoti make breaker
Vaccum Contactor
Rewinding of control transformer of input0-375 –415 VA of following specification
Upto 200 VA rating
Above 200VA to 400 VA rating
Above 400VA to 1000 VA rating
Above 1000 VA to 1500 VA rating
13000 VA rating
Rewinding of MLC Contrator coil of BHEL make with Coil voltage 110V DC and current rating of 150 Amps.
Rewinding of 0.4 KV Motors upto 10 KW capacity
Upto 1 Kw
Above 1 KW upto 5 KW
Above 5 KW upto 10 KW
Rewinding of 0.4 KV Motor above 10 KW upto 175 KW(rate is to be quoted in Rs/KW)
Rewinding of D.C. Motors of CHP
Rewinding of D.C. Generators of CHP
Rewinding of hooters (Fractional H.P.)
Repair of damaged rotor of chain hoist by brazing etc.
Rewinding of following fan motors.
Ceiling fan
Cabin fan for operator
Exhaust fan of desert cooler
Painting of Motor body 15 KW to 175 KW
Replacement of bearing of 0.4KV Motors/DC generators.
Upto 1Kw.
Above 1Kw to 5Kw
Above 5KW to 15 KW
Avove 15 KW to 25 KW
Avove 25KW to 175 KW
Maintenance of 6.6 Kv Jyoti make Breakers , Power Transformers, 0.4 KV modules, MCC and electrical Panels of CHP
Daily checking of 52 Nos. Jyoti make MOCB/VC and 04 Nos. 6.6/ 0.4 KV Transformer
Dismantling and re-assembly of breaker
Overhauling of complete Breaker (Breaker mechanism and pole parts)
Overhauling of pole parts only.
Overhauling of L.T. Transformer
Centrifuging of oil of L.T. Transformer
Cleaning of complete L.T. Transformer
Arresting of oil leakage from pipe line joints etc. of the transformer
Cleaning of Transformer yard area and its surrounding
Maintenance of 6.6 KV Bus (Cleaning, checking/ tightness & repairing)
Replacement of CT’s with new/old one of 6.6 KV breaker
Internal and external cleaning of CHP Electrical Panels, MCCs, DE/DS, JBs, LCCs, LDBs, etc as per scope of work.
Daily checking and maintenance of Siemens make 0.4 KV module of switch gear rooms ACDB-I and ACDB-II as per scope of work.
M/S SCINTECS PROCESS CONTROL
M/S PRAKASH ELECTRICAL WORKS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .