Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.7 CrAccepted-AOC | ₹18.7 Cr | L1 | Accepted-AOC lowest tender |
| 2 | L2₹19.7 CrRejected-Finance | ₹19.7 Cr | L2 | Rejected-Finance LOWEST TENDER |
| 3 | L3₹20.0 CrRejected-Finance | ₹20.0 Cr | L3 | Rejected-Finance NOT BEING LOWEST |
| 4 | Rejected-Technical | - | - | Rejected-Technical NOT APPROVED FOR OPENING OF SECOND COVER |
| 5 | Rejected-Technical | - | - | Rejected-Technical NOT APPROVED FOR OPENING OF SECOND COVER |
Tender Value
Refer Docs
EMD Value
₹11.8 L
Closing Date
27 Dec 2021, 6:00 pmClosed
Chief Engineer
HQ Chief Engineer Delhi Zone
ADDN/ALTERATION and REPAIR OF MAIN BUILDING AND OTM ACCN OF ARMY HOSPITAL (RR) UNDER GE (E/M) RR HOSPITAL DELHI CANTT-10
2021_MES_480524_2
CEDZ-31 OF 2021-22
Open Tender
Civil Works
365 days
Delhi Cantt
MES contractor enlisted in MES under class SS cat a i and c(i)having deposited Standing Security of Rs 15.00 lakh with department. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and categ
9 documents required · 9 mandatory
₹3,000
GE (E/M) RR Hospital
₹11.8 L
Yes
12 Jan 2022
1 Dec 2021
29 Dec 2021
1 Dec 2021
27 Dec 2021
8 Dec 2021
Amount
Dismantling of walls and ceiling boards or insulation board of any type board complete all as specified and directed.
Dismantling plain or corrugated polycorbonate sheeting any guage, thickness including fixture etc fixed with self tapping screw complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition dholpur stone and granite of any description or thickness in walls/floors etc and including removal of cladding, any PCC padding etc complete all as specified and directed.
Taking down chowkhat or frames with shutter (without taking off shutter from frame) area n exc 1.50 Sqm and removal from site complete all as specified and directed.
Taking down chowkhat or frames with shutter (without taking off shutter from frame) area exc 1.50 Sqm but n .exc 4.00 sqm each and removal from site complete all as specified and directed.
M & L for non-skid ceramic coloured tiles 7 to 8 mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors etc. over & including 15mm thick screed bed in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for 10 mm thick rendering in cement mortar 1 : 4 on brick work or concrete surfaces of walls for fixing of tiles complete all as specified and directed.
M&L for glazed ceramic colour tiles in vertical surface of size 450 X 300 x 7 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles complete all as specified and directed.
M&L for 18 to 20mm thick granite of any type (table rubbed & polished) in floors, jambs, pillars, window cills, plate forms and like in CM (1:4) including pointing in white cement (1:2) ,using marble dust with admixture of pigment to match with shade of granite, laid over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.\
M & L for 20-25mm thick, machine cut, Kota stone slab, as in floors, steps, landing etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of slab, including cutting, polishing etc. with and including 20mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for 18-20 mm thick machino polished marble floor slab as in flooring ( Bttochino marble ) size as requried at site with neat cement slurry floated over bed mortar pigment to match with shade of floor slab , joint to have hair line finish and finished with matching colour pigment and white cement curing ,rubbing ,mirror polishing , washing ,cleaning ,making cut out for services complete all as specified and directed.
M&L for 18-20 mm thick machine polished marble slab in skirting ( Bottocino marble) size as per site requirement with neat cement slurry floated over bed mortar pigment to match with shade of floor slab , joint to have hair line finish and finished with matching colour pigment and white cement curing ,rubbing ,mirror polishing , washing ,cleaning ,making cut out for services complete all as specified and directed.
M&L for Vitrified ceramic tiles 10mm thick dark shade (square/ rectangular) area of each tile not exceeding 0.36 sqm, in floors etc over and including 20 mm thick screed bed in cement mortar 1:6 and jointing in neat slurry and pointed in coloured cement to match the tile and set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for Vitrified ceramic tiles 10mm thick dark shade (square/rectangular) area of each tile exceeding 0.42 sqm, but n. exc 1.50 sqm in floors etc over and including 20 mm thick screed bed in cement mortar 1:6 and jointing in neat slurry and pointed in coloured cement to match the in . set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
S&F in repair for Dholpur stone 25-30mm thick cladding gang-saw cut machine cut edges, uniform colour of each stone size exc 0.25 sqm area and not exc0.50 sqm area (Stone size as per site) fixed with and including one number SS clamps (grade 202 ) of flat 30mm x 2mm ,150 mm long made to shape in each slab ,making V groove at top and bottom of stone and drilling hole for fastner ,polishing ,rubbing & including silicon treatment and grouting with CM 1:3 (SS Fastners 75-100mm long ) complete all as specified and directed.
Providing and fixing factory made UPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories
S&F aluminium powder coated grill (DECO grill DG 103 Of 10mm thick of M/s ELESAR, M/s Royal Grill, M/s Natinal Grill Associated profiles & Aluminium Ltd) fixed with suitable 'F' section (No 8584) 15.30 X 23.40 X 1.40mm (minimum), fabricated and riveted to aluminium window / ventilators complete all as specified and directed.
M&L 5.5 mm thick tinted glass including necessary clips, rubber packing & aluminium beading (aluminium frame ) complete all as specified and directed.
S&F factory made single extruded WPC (Wood polymer composite) soild door frame of size 65mmx100mm comprising of virgin PVC polymer of K value 58-60 (suspension grade) calcium carbonate and natural fibers (wood powder/rice husk/weat husk) and non toxic additives (max toxicity index of 12 for 100gms) fabricated with mitred joints after applying PVC solvent cement and screwed with full body threaded star headed SS scerws having min frame density of 750 Kg/cum, screw withdrawl strenght of 2200 N (Face) 1100N (Edge) min compressive strenght of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of frame of class A category with property of being termite/borer proof, water/moisture proof and fire retrandant complete all as specified and directed
S&F factory made single extruded WPC (Wood polymer composite) soild plain flush door shutter of 30mm comprising of virgin PVC polymer of K value 58-60 (suspension grade) calcium carbonate and natural fibers (wood powder/rice husk/weat husk) and non toxic additives (max toxicity index of 12 for 100gms) fabricated with mitred joints after applying PVC solvent cement and screwed with full body threaded star headed SS scerws having min frame density of 750 Kg/cum, screw withdrawl strenght of 2200 N (Face) 1100N (Edge) min compressive strenght of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of frame of class A category with property of being termite/borer proof, water/moisture proof and fire retrandant and fixing with stainless Steel butt hinges of required size with necessary full body threaded star headed countersunk SS screw complete all as specified and directed
M&L in repair for exposed GI frame/grid system duly powder coated for module size of 600 x 600 mm suitable for lay-in aluminium / mineral fibre ceiling tiles, having main T runner of 24 mm size, suspended at 1200mm C/C and cross T runner of 24 mm size, suspended at 600mm C/C with interlocking arrangements to form grid of 600 x 600mm, perimeter runner/channel of 15 mm size, main and cross T runner supported by 4mm dia GI rod from slab / Roof, wall angle etc with and including all fixing accessories , complete all as directed.
M&L in repair for metal false ceiling, lay-in type, 0.5 mm thick, having tegular edge profile, duly powder coated, perforated type with glass fibre acoustic fleece, suitable for false ceiling grid/frame module of 600 x 600mm size, complete all as directed.(Note : The grid /frame shall be measured and paid for separetly.)
S&F in repair false ceiling of 12.5 mm thick tapered edge gypsum board confirming to IS 2095 including providing and fixing frame work made out of special sections power pressed from MS Sheet and galvanised in accordance with zink coating and consisting of angle cleat of size 25 mm wide X 1.6 mm thick with flange of 22 mm and 37 mm at 1.2 mtr C/C , Angle fixed to the ceiling with dash fastener 12.5 mm dia x 40 mm long with 6 mm dia bolts to the angle hangers of 25x25x5 mm running @1.2 mtr C/C to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm , shall be fixed in a direction perpendicular to GI Channel with connecting clips made out of 2.64 mm dia x 130 mm long GI wire at every in including fixing the gypsum board with ceiling section and perimeter channel 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long the perimeter of ceiling fixed to wall / partition with the help of raw plug at 450 mm c/c with 25 mm long screws @ 230 mm internal including jointing and fixing to a flush finish of tapered and square edge the gypsum board with filler and finish with POP as per approved colour, paper tapes including making opening for light fittings ,AC grills,diffusers cut outs made with frames of perimeter channels complete in plain horizontally / vertically location including applying coats of plastic emulsion paint over a coat of approved primer on gypsum board false ceiling horizontally / vertically as specified (at ceiling height up to 8 mtr appx) complete all as specified . Note: Dismantling of E/M & AC services such as cables and supply lines, ducts and any other service lines has to be removed and refixed as per E/M schedule without affecting existing services and problem during execution .
S&F in repair of ROLLER blinds vertical type 100% polyster (translucent) wt 230gm/sqm made out of fabric cloth of approved shade fixed as per the instructions of manufacturers, complete all as specified.
S&F in repair of venatian blinds vertical type 100mm wide louvers made out of fabric cloth of approved shade fixed as per the instructions of manufacturers, complete all as specified .
Demolition of brick work or stone/boulder masonry built in cement mortar complete all as specified and directed.
M&L Brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
M&L for 15mm thick ready mix plaster on brick or concrete surfaces of walls finished even and smooth complete all as specified and as directed by Engr-in-Charge
M&L for rendering in CM (1:4) 15 mm thick using water proofing compound @ 2% of weight of cement as per manufactureres on brick surfaces or concrete surfaces even and smooth without using extra cement complete all as specified and directed.. (Note : WPC shall be measured & paid separatelly)
M&L for 10mm thick rendering in CM (1:6) on brick work or concrete surfaces even and smooth without using extra cement.
M&L in repair surgical scrub station made of stainless steel 304 gde with sensor operated 02 nos surgical tap / mixer (weight of scrub station 110 Kg to 120 Kg) complete all as specified.
S&F for 5mm thick PVC fillet of width 35mm for wall panelling inclusive for fixing on to wall to make PVC frame as per specification complete all as specified and directed.
S&F solid PVC wall panelling consisting of 5mm thick wood grain finish PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specification and drawing complete all as specified.
Supply fabricating and fixing in repair of aluminium door powder coated of extrusion aluminium section, Vertical style of door shutter of size 85mmx44.45mmx1.8mm thick. Top, middle and bottom rail of size 85mmx44.45x1.8mm thick and fixing 5 mm thick plain/tinted sheet glass of Modi guard/Atul or prelaminated particle board 9 to 10mm thick of make Kit Ply with aluminium beading and rubber gasket/beading as directed One mortice lock for aluminium door (each) and two aluminium tower bolts of 200mm size for each door fixed with rawl plug including rectification of floor/wall to match the existing surfaces all as specified and as directed by Engineer-in-Charge at site. (Cost of sheet glass Plain/frosted/particle board shall be measured and paid seprately )
S&F in repair of figured glass, pinheaded type in squares n.exc 0.5 sqm each panes 4.0 mm thick, as in aluminum window/Ventilator/door, including rubber packing and aluminium beading complete all as directed.
S & F 1mm thick Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete; push pull or manual type complete all as specified and directed.
S & F in repair 1mm thick Steel rolling shutters,but gear operated type with bevel gear box and crank handle, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete; push pull or manual type complete all as specified and directed.
M&L for wooden flooring, laminated wooden type made of high density fibre board (HDF), comprising of tongue and groove interlocking type of planks of 1210 x 193mm size 8mm thick, commercial grade, abrasion resistance of AC-III category, with and including all fixing material i.e chemical adhesive, base strip /fillets etc veneered and matching top beading etc all as directed.
S&F in repair of cup board / drawer knob of stainless steel with matt finish fixed with screw, complete all as directed.
S&F of SS (Gd-304) brackets, angles, hollow tubes, flats etc of any shape and size with & including SS screws / fasteners etc and all kind of machine works i.e. cutting, welding, bending, moulding, grinding, polishing, buffing etc to get the required shape and size, fixed to any position and at any surface etc, complete all as directed. (Note : All fixtures and fittngs should be of stainless steel)
M&L 8mm thick multi layer coloured polycarbonate plastic translucent sheeting fixing with aluminium strip and gasket and self taping screws on roof trusses complete all as specified and directed.
M&L for PVC profile for wall panelling of size 23cm wide, 8mm over all thick and 01mm wall thickness fixed with screw to mild steel tubular steel frame work made out of MS Hollow section of size 25mm x 15mm x 2mm spacing 01 meter on both side frame work shall be fixed in wall with the help rawl plug and required length of screws and MS work shall painted with one coat of red oxide primer for wall paneling complete all as specified and as directed by Engineer-in-Charge.
Providing and fixing in repair aluminium composite panels cladding of approved make having total thickness of 4 mm (Top coil -0.5mm , non Toxic PE - Core - 3 mm and back Coil -0.50 mm ) with 25 micron PVdF Coating on top coil and polyester / epoxy coating on back coil ( 4-7 microns ) on aluminium substructure fixed with 19 mm x 12 mm x 1.6 mm aluminium cleat & 10 x 100 mm SS Wooden screw with PVC plug on faced horizontal/ vertical surfaces of rectangular / circular columns ,suspended ceiling Cills , jambs ,canopy with including neccessary aluminium frame ,scafolding etc and making 12 mm to 20 mm wide grooves and applying non staining and non streaking sealant of Dow corning ( 789 or 991 HP) and backing rods complete as specified and approved shade by Engr in charge . Only exposed surface shall be measured and paid for ACP Material shall be for exterior application &of shade as approved by Garrision Engineer .
S&F PVC 18/19mm thick PVC moulded solid board, one side prelaminated for cabinets boxes, shutters , etc with shelf and shutters full size fitted under/above kitchen cooking platform and other platform complete all as direction of the Engr-in-Charge and the manufacturer specifications and drawings.
S&F 3mm thick aluminium coated panel (ACP Sheet) including necessary clips, rubber packing & aluminium beading (aluminium frame ) complete all as specified and directed.
M&L in repair 0.9mm thick decorative laminate type 1 of surface finish, fixed with approved adhesive smooth surface finish, wooden texture colour and pattern, including taking down of old laminates, complete all as specified and directed.
S&F in repair 10 mm thick toughened tinted glass panels in vertical profile as directed by the Engr-in-Charge . The glass panels shall be supported by existing glass mullions and held by existing spider fittings ,spring plates ,counter sunk bolts . All joints between the glass panels / glass mullions shall be sealed by colourless structure silicon sealant all as directed by Engr -in -Charge .
M&L sensor for operating toughened glass sliding door with complete fittings and sliding accessories complete all as specified and directed. Make Dorma
S&F toughened glass frameless door with fixed portion, of 12 mm thickness, including cutting holes, edges rounded and etching works etc and all kind of SS patch fitting & fixture, spider patch etc, complete all as directed.
S&F toughened glass frameless window with fixed portion, of 12 mm thickness, area of window upto 4.00 sqm in single piece glass including cutting holes, edges rounded and etching works etc and all kind of SS patch fitting & fixture, spider patch etc, complete all as directed.
S&F of stainless steel handle 600 mm long fixed to 12 mm thick toughned glass door with and including all fixing accessories i. e. bolt washer, adhesive etc, complete all as directed.
S&F of SS door lock, glass to glass type, suitable for 12 mm thick frameless toughned glass door with and incl all fixing accessories i. e. bolt, washer, screw, adhesive etc of suitable size, complete all as directed.
Supplying and installing in repair, openable double swing double leaf doors in required sizes in structural glazing system using 10 mm thick toughened clear glass including providing & fixing necessary imported stainles steel frame finished hardware fitting patch fittings , 2 Nos 300 mm size back to back S.S handles per shutter , Heavy duty floor springs for external applications , locking arrangements , keys etc . all as directed by Engineer- in - Charge .
M&L for complete removal of existing treatment from wall /ceiling by electric operated grinder machine and applying 1-2 mm thick wall care putty , two coats of plastic emulsion paint over a coat of primer complete all as specified and directed by Engineer-in-Charge.
M&L preparation of old treated surface of walls and applying one coat of white wash on wall surface complete all as specified.
M&L preparation of old treated surface of ceilling and applying one coat of white wash on ceilling surface complete all as specified.
M&L preparation of old decorated surfaces including preparation of surfaces and applying one coats of acrylic exterior emulsion complete all as specified..
M&L prepration of old treated wooden surfaces of any description over 10cm girth or width, not otherwise specified and applying one coat of French polishing of any description including cleaning.Shade of the polish shall be as directed by Engineer-in-charge, complete all as specified.
M&L complete removal of existing treatment from wall /ceiling by electric operated grinder machine and applying 1-2 mm thick wall care putty and applying one coat of texture paint by using paint roller/spray machine including necessary scaffolding as required for upto 20 mtrs height complete all as specified.
M&L for preparation of new surface and applying two coat of oil bond distemper on wall over 3mm wall care putty complete all as directed and specified.
M & L for complete removal of existing treatment of surfaces by steel wire brushing, scraping down smoke soots, moulds, moss and efflorescent salts over all decorated plastered or un plastered surfaces wall and applying two coats of oil bound distemper white or tinted over chalk whiting complete all as specified and directed.
Description of Work / Item(s)
Amount
Taking down carefully existing false ceiling & Duct of any type / make / size including all electric fitting/fixture, fire alarm and any other accessories etc for repair/replacement of AC duct and refixing the same in its original position with out any damage complete all as directed. Note: If, any kind of damage occured to false ceiling and other services like elcetric supply cable / fitting / fixture, fire alarm, water supply line or any other services, due to negligance or poor workmenship of contractor, the same will be repaired/replaced by the contractor free of cost and no extra payment will be made in this effect to the contractor.
Supply, installation (including all fixtures/frames), testing and commissioning of GSS Duct of 22 Gauge including taking down old duct complete all as specified and directed
Supply and fixing of thermal insulation on Duct with nitrile rubber 15 mm thick complete all as specified and directed
S&F in replacement of the GI Dampers with 20 guage as per IS duly powder coated and as per existing size. The cross section area up to 0.5 Sqm ,fixed on wall with supply air duct complete all as specified and directed
S&F in replacement of the aluminium Dampers in supply and return air duct with suitable guage as per IS and existing size for the purpose of control Air quantity of various wards and Departments complete all as specified and directed
S&F in replacement single deflection grill commonly used for return air inside wall and ceilings without need of an opposed blade damper since return air is not normally room balanced complete all as specified and directed
S&F in replacement Double deflection grill commonly used for return air inside wall and ceilings without need of an opposed blade damper since return air is not normally room balanced complete all as specified and directed
S&F in replacement of Aluminum grills of suitable guage as per existing size,fixed on wall with return air duct complete all as directed.
S&F in replacement of Aluminum diffuser of size 12" x 12", made of 22 guage aluminium sheet, duly powder coated, fixed on false ceiling of any type with return air duct, complete all as directed.
All as per srl item No 9 here-in-before but of size 15" x 15"
S&F in replacement of Aluminum diffuser of size 600 x 600 mm with opening(300x300mm), made of 22 guage aluminium sheet, duly powder coated, fixed on false ceiling of any type with return air duct, complete all as specified and directed
S&F in replacement of Aluminum diffuser of size 600 x 600 mm with opening(450x450mm), made of 22 guage aluminium sheet, duly powder coated, fixed on false ceiling of any type with return air duct, complete all as specified and directed
Supply, install, commissioning and testing of commercial air curtain unit of size 28 inch x 78 inch for prevention of dust and conditioned air loses, single phase, 220V, 50 Hz made out of MS/CRCA sheet of minimum thickness 18 Gauge finished with two coats of synthetic enamel paint (oven baked) with MS-CRCA 18 Gauge square perforated suction grill , Aluminium alloy fans and sigle phase electric motor, nozzles etc complete with fitting and accessories so as to produce 1-1.5 m/sec air velocity at floor level for door opening complete all as specified and directed
Description of Work / Item(s)
Amount
Taking down cement plaster on brick walls built in cement mortar including raking out joints, hacking for key, scrubbing down with water etc all as specified and directed by Engineer-in-Charge
Demolition of cement concrete (unreinforced) in ground floor and pavings n.exc 15cm thickness (below or above ground level) all as specified and directed by Engineer-in-Charge
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc all as specified and directed by Engineer-in-Charge
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Excavation over areas n.exc 1.50m deep and getting out in hard/dense soil complete all as specified and directed.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
M&L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed.
Returning, filling in including spreadng, levelling, watering and well ramming in layers n.exc 25cm (after the pipes have been laid and tested) complete all as specified and directed.
Removing excavated soil n.exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 (40mm graded stone aggregate) in foundations filling and mass concrete complete all as specified and directed.
M&L for hard core of guage n.exc 63mm deposited, spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface of broken stone orboulders complete all as specified and directed.
M&L for 80mm thick, M-40 grade machine pressed precast interlocking paver block any shape and size with grey cement and pigment conforming to IS 15658-2006 laid over sand complete all as specified and directed. Note :- Sand shall be measured and paid sepretely under respective item of BOQ.
M&L for chequered cement concrete tiles 20cmx20cmx25cm thick set, jointed and pointed in neat cement slurry in floor with grey cement and no pigment over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for brick work with sub class 'B' bricks old size bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 (20mm graded stone aggregate) as in coping including form work, bed plates, benching, blocks etc complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 mixed with water proofing compount @ 3% by weight of cement finished even and smooth without using extra cement complete all as specified and directed. Note : Water proofing compound shall be measured and paid separately.
Supply only liquid water proofing compound complete all as specified and directed.
M&L for precast cement concrete 1:2:4 type B-1 (20mm graded aggregate) as in manhole covers and similar works complete all as specified and directed by Engineer-in-Charge. Note : Reinforcement shall be measured and paid separately under respective items of BOQ.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia all as specified and directed by Engineer-in-Charge
M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spares and binders all as specified and directed by Engineer-in-Charge
M&L for PCC 1:2:4 type B-2 (40mm graded aggregate) as in surfaces channels and drains complete all as specified and directed by Engineer-in-Charge
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/ stopped ends etc complete all as specified and directed.
M&L framed work such as grills, gratings and similar works conforming to Fe 290 Gde E-165 complete all as specified and directed.
M&L for 200 mm bore reinforced concrete pipe class NP2 laid and jointed complete with collars complete all as specified and directed.
M&L for 250 mm bore reinforced concrete pipe class NP2, laid and jointed complete with collars all as specified and directed by Engineer-in-Charge
M&L for 300 mm bore reinforced concrete pipe clas NP2 laid and jointed complete with collars complete all as specified and directed.
M&L for concrete bed type C2, 1:3:6 for 200 bore pipes including packing under and haunching against the sides after they are laid and tested in complete all as specified and directed.
M&L for concrete bed type C2, 1:3:6 for 250 and 300 mm bore pipes including packing under and completely surrounding pipes with concrete after are laid and tested in complete all as specified and directed.
M&L formwork for flat fair finish surface of concrete to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed.
M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
M&L RCC (Nominal Mix) type B-1 1:2:4 (20mm graded stone agg) as in Beams, cantilevers, bressummers,lintels over 1.5m span complete all as specified and directed.
S & F of MS round bars 10mm dia and overconforming to Fe-410(Gde.E-250) Part- I quality-A or Fe 290 (Gde - E-165) , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to, complete all as specified and directed.
S & F of MS TMT bar deformed, 6 to 8 mm dia and over cut to length, bent to shape including cranking, binding with MS wire of dia not less 0.9 mm dia, complete all as specified and directed.
M&L in repair for factory made RCC drain cover with cover frame comprising of 75 mm thick cover, area of each cover slab exc 0.5 Sqm & n exc 1.00 sqm including provision of hot dip galvanized lifting hook for lifting overall cover with suitable size angle iron frame, RCC cover of M30 or higher grade concrete by vibro compression process, medium duty, confirming to IS-12592 including fixing on manhole, demolition of existing cover with cover frame and removal of debris from site complete all as specified and as directed.
M&L for cutting into existing manholes for inserting SWG / RCC pipe upto 300mm dia and making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section ) in cement concrete 1:2:4 type B-I, smooth finished and reforming benching as required, complete all as directed.
Description of Work / Item(s)
Amount
Structural Repairs : Chipping and Dismantling Carefully chipping , removing existing plaster/damage RCC structure upto any thickness by low impact high frequency hammer/chipper without damaging the original sound brickwork or concrete including racking of joints, daily cleaning and stacking of debris at prescribed location in polypropylene/ paper bags, disposing off the debris so generated on weekly basis out side the premises, etc. complete as directed by Engineer-in - charge. (Note: Scaffolding, debris disposal and enabling items not paid seperately, extra thickness if any will not be paid additionally)
(a) Column
(b) Beam, Chajja, fascia
(c) Slab
Examining concrete by tapping with light hammer and marking of the loose concrete areas of structural elements in straight line geometrical forms, grooving the edges same with grinder up to 5 -10 mm depth without damaging existing rebars, carefully removing carbonated concrete around the rebars up to 10 mm depth by low impact high frequency hammer/ chipper without damaging the sound concrete, as shown in the figure in the detailed methodology, daily cleaning and stacking of debris at prescribed location in polypropylene/ paper bags, disposing off the debris so generated on weekly basis outside the premises, etc, complete as directed by Engineer-in-Charge. (note : scaffolding and enabling, debris disposal items not to be paid separately).
(a) Column
(b) Beam, Chajja, fascia
(c) Slab
Improving Microstructure of concrete by grouting Improving Microstructure of concrete by grouting :- (a) Identifying the member to be repaired for structural cracks/porosity/ honeycombing/ imperfections by injecting grouting. (b) With the help of electrically operated angle grinder with diamond saw blade,make V shaped groove crack line of up to 10 mm wide and up to 10 mm deep. The crack line will be cleaned by air blower. (c) This crack will be identified and named uniquely for record purpose as recommended by Engineer in charge and approved by GE.Sealing of exposed V groove 10 mm deep and 10 mm wide with Sikadur®-31(IN) solvent-free, moisture tolerant, thixotropic, two part structuraladhesive and repair mortar, based on epoxy resins and special fillers. (d) Drilling Holes of 12mm dia, up to 100 mm deep holes in beams and columns and 50-75mm deep in slab at the interval of 300-500 mm in staggered manner or along the crack line as directed by the Engr-in-charge in Reinforced Concrete (RC) structural element including cleaning of the holes by air blower and inserting 10-12 mm dia NRV (Non Returnable Value) nozzle compatiable with epoxy injector and having machined external end to receive outlet of Grouting Gun. Fix it inside the hole by applying thixotropic epoxy solvent free moisture tolerant putty to ensure complete sealing and allow to cure the system for minimum of 8 Hrs before Grouting including nozzle projections, excess putty, if any, over concrete element by grinding, levelling and finishing the external surface, after completion of the work, etc., complete.
(a) Column
(b) Beam
(c) Slab
Grouting injecting Sikadur®-52 LP (IN) two part, low viscosity injection resin, based on high strength epoxy resin by pressure and using pressure epoxy injector with accessories till nozzle refused to accept the grout including mixing of grout having Mixed Density 1.1 kg/l (at +27°C); Viscosity ~ 250 mPas at +30°C and should comply according to ASTM C 881, Type II and IV, Grade-1, Class E+F and should have below properties. Compressive strength >= 70 N/mm2 (7 days) according to ASTM C 579; Tensile Strength ~ 50 N/mm2 (after 7 days at +30°C cure) (According to ASTM D 638); Tensile Modulus ~ 2000 N/mm2 (after 7 days at +30°C cure) (According to ASTM D 638); Bond Strength ~ 10.8 N/mm2 (failure in concrete) after 14 days at +30°C cure; Flexural strength ~ 50 N/mm2 according to ISO 178. Seal the nozzle with thixotropic epoxy putty after the refusal of grout material from the nozzle. Note: leakage through other nozzle or cracks are required to be monitored while grouting and such points to be sealed as and when required without any extra cost.
(a) Column
(b) Beam
(c) Slab
Steel Protection: Anti-Corrosive Treatment and Corrosion Inhibitor Clean existing reinforcement with wire brush/rotary wire brush to make surface free from rust scales, loose material, diet etc, complete and proving, applying two coats of alkaline rust converting primer Sika RustOff-100 or equivalent on the existing rebar and allowing it to react with rust for 6 hrs and form corrosion resistant, insoluable and adherant protective layer, including cleaning the reinforcement, wire brushing to remove the rust spalls, with time interval of 1 hour between the coats. The location will be as approved by Engr in charge. Note :Area of structural section treated has to be measured inclusive of steel & concrete.
(a) Column
(b) Beam
(c) Slab
Providing applying brush application, curing to form anticorrosive with SikaTop Armatec 108, high bond strength of anticorrosive polymer modified cementious coating for corrosion inhibiting protection of reinforcement in two layers of total thickness of 2mm. The second coat shall be applied after 2-3 hours of first coat. (Measurement will be as per surface area of both steel & concrete). Note :Area of structural section treated has to be measured inclusive of steel & concrete.
(a) Column
(b) Beam
(c) Slab
M&L for applying on hardened concrete surface organic migratory corrosion inhibitors (MCI) of minimum two coats of amino alkanolamine (AMA) nature. The location will be approved by Engr-in-Charge.
(a) Column
(b) Beam
(c) Slab
Provision of Additional Rebar Providing and fixing additional corrosion resistant steel rebar 10 mm dia and over Fe500D as per required diameter in various structrural elements such as columns, beams, and slabs etc. to replace the lost rebar section due to corrosion including cutting, bending and fixing the bar ,tieing with preleft bars by GI binding wire,retouching local damages in coating if any of with zinc spray,etc complete all as specified and directed by Engr-in-Charge.
Installing rebars of dia 10 mm and above in the building components i.e beam, col and slab with chemical anchoring compound Epoxy Acrylate based anchoring adhesive Sika AnchorFix - 2+ Tropical by Drilling holes of dia and depth as per manufacturers instruction complete all as directed.
Concrete Section Buildup Rebuilding the section of damaged RCC elements to its original size or as directed by Engineer in charge in thickness exceeding 40mm but not exceeding 100 mm by providing and casting with pre-packed duel shrinkage compensated free flow self compacting microconcrete of grade M40 and above including providing and fixing of watertight foam faced finish shuttering of minimum 18 mm thick with supporting framework ,all lead and lift,mixing,placing,deshuttering,levelling the surface by grinding off cementitious slurry of construction joints differences if any to satisfaction of Engr-in-Charge, curing etc,complete all as specified .For Note :-( Rate including cube test to be conducted for every 5 M.T work done,6 nos for sample required per test).
(a) Column
(b) Beam/ Chajja
Rebuilding the section of damaged RCC elements to its original size or as per Engr in charge recommendations in thickness up to 40mm in layers of not exceeding 20 mm each by providing and applying with hand single component dual shrinkage compensated thixotropic mortar (PMM) of grade M40 and above, including all lead lift, mixing by addition of water only as per manufacture's recommendation, levelling the surface, curing etc complete all as per specified. Note :-( Rate including cube test to be conducted for every 5 M. T. work done, 6 nos of sample required per test)
(a) Column
(b) Beam/Chajja
(c) Slab
M&L for gunniting work to RCC work in columns beams, chajja, balconies, slabs landing etc by removing loose concrete, incl removing rust with short blasting and Cleaning of surface with wire brush and applying epoxy treatment to rusted reinforcement and including S&F welded wire mess fabric or wire not less than 95x95x3mm adhesive plaster grade for concrete admixture and providing gunniting pressure 2.00/2.50 Kg/ Sq cm with admixture 1 Part of cement and 3.50 part of sand and thickness 50mm average and making the surface even and smooth including necessary form work and 5mm thick plaster over repaired surface upto 4 storeys building complete all as specified.
M&L 15mm thick rendering in CM 1:4 external face of walls finished fair even and smooth without using extra cement.
Providing and applying 25 mm thick PMM in two coats of 15 mm and 10 mm each with single component pre-packed fibre reinforced dual shrinkage compensated thixotropic polymer modified mortar , icluding cost of required scafolding up to 20 meter height building.
All as per item no 14 (here-in-before) but Making edge(dhar) or corner or 1" patti or Groove or nosing in plaster surface including transporting of material, cutting, tools, mixing, curing, etc. complete all as specified and directed. (Note :- Measurement in Rmt of edge available)
M&L applying 1-2 mm thick wall care putty and applying one coat of texture paint by using paint roller/spray machine on new surface including necessary scaffolding as required for upto 20 mtrs hight complete all as specified and directed.
Description of Work / Item(s)
Amount
Demolition of mud phuska from roof any thickness including leapeing plaster including removing off the demoltion material from roof complete all as specified and directed
Dismanlting of Brick (laid flat or on edge ) or brick tiles in floors etc complete all as specified and directed
Repairing surface irregularities, damaged concrete slab, if any, with an latex polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools and tackles (Maximum avg upto 12mm) complete all as specified and directed
Prepare V groove & repairing of crack with Construction+, Single component Polyurethane sealant for other than crack repair under structural section complete all as specified and directed
M&L for providing cement concrete as padding concrete average type B-0 (1:2:4) using 12.5mm graded stone aggregate with water proofing compound (mix of WPC qty as per manufacturer instruction) supplied at site and placed in position by RMC lifted by mechnical pump, laid on roof slab finished even and smooth and diamond cut depth 25 mm at construction joints and filled with polysulphide complete all as specified and directed
Make Panel grid of 3.00 X 3.00 metre and cutting groove of 6mm x 10mm in concrete screed and filling the same with single component Sikaflex PU sealant complete all as specified and directed
M&L 20 mm thick rendering in CM 1:4 external surface of top roof slab , finished even and smooth without using extra cement mixing with integral water proofing compound etc complete all as specified and directed(Note :- WPC shal be measured and paid separately)
Supply only integral water proofing compound mixing with plaster mortar as per manufacuturer instruction complete all as specified and directed
S&F 2 ply APP system is to be terminated, a 20 mm x 20 mm chase should be provided. The membrane should then be dressed into the chase and pointed immediately with a bitumen putty, or similar approved bituminous sealant. The termination shall be done ideally minimum 300mm above finished roof level complete all as specified and directed
S&F 300gsm geotextile as separation layer complete all as specified and directed
EXPANSION JOINT TREATMENT Surface Preparation: Preparing the substrate by cleaning, drying, making it sound and free from surface contaminants. Removal dust , laitance, grease, oils, curing compounds, form release agents & other foreign particles by wire brushing, grinding etc., including removal of all old sealant and other treatments (if any) . If the joints edges are not in perfect shape , they have to be prepared in proper shape complete all as specified and directed
Repairing the edges of the joint (in case of weak concrete at the joint edge) and also configuring the joint width (in case of expansion joints with irregular width more than the width of the chosen Sikadur Combiflex Tape width) with epoxy repair mortar Sikadur 31 and Sikadur 41 complete all as specified and directed
Supply and apply epoxy based membrane adhesive Sikadur®-31 C @ 1.0 kg/m as base coat having mixed density: 1.75 kg/ltr; bond strength > 1.5 N/mm2 on both sides of joint complete all as specified and directed
Supply and apply 2mm thick & 300mm width flexible FPO based membrane Sikafdur®-Combiflex® SG System chemical Base Modified flexible Polyolefin (FPO) with advanced adhesion. Fire Rating Euroclass E (EN ISO 11925-2, classification to EN 13501-1), Service Temperature -30°C min. to +40°C max. in wet conditions -30°C min. to +60°C max. in dry conditions. And the product should have Tensile Strength > 12 N/mm2 (EN 12311-2), Tear Strength > 40 N/mm (ISO 34-B), Elongation at Break > 600 % (EN 12311-2) and should pass thermal aging: 7500 h passed (SIA V280, 1996) complete all as specified and directed
Supply and apply epoxy based membrane adhesive Sikadur®-31 C @ 3.0 kg/m as base coat having mixed density: 1.75 kg/ltr; bond strength > 1.5 N/mm2 on botyh sides of joint complete all as specified and directed
Supplying & applying metal 0.5mm thick and 400 mm wide aluminium sheet for protection of membrane complete all as specified and directed
BASEMENT WATERPROOFING WITH PU INJECTION Drilling and fixing injection packers in RCC, including: Drilling Holes: Drilling holes 10mm diameter in structural concrete at the intervals as per recommendation of engineer in charge. Cleaning of holes: Clean the holes by air blower prior to fixing nozzles. Fixing of Packers: Sika® Packer, 9.8mm diameter, 10cm long, with high strength steel screw and structured rubber sealing, in cleaned holes Cutting of Packers: Cut the packers by cut of wheel after completion of grouting without damaging structural elements.
Supply and apply Sika® Injection 101h, one component, Polyurethane Injection foam based system for wet condition and temporary sealing, which cures to a dense flexible foam with a fine cellular structure. Product Requirements: Viscosity cps 500-1300 at 23°C complete all as specified and directed
Supply and apply Sika Injection 202IN, two component, elastic, low viscous, solvent free, Polyurethane Injection resin based system for permanent sealing, that does not need the presence of water for hardening reaction. Product Requirements: Viscosity of mixture ~ 250 - 600 mPa•s (at +30°C) -> Conformance label that product is approved to the essential requirements and under market surveillance complete all as specified and directed
Providing & applying of levelling & moisture barrier with 3-part cementitious epoxy based surface sealing system on the prepared surface having minimum 2mm built up thickness using Sikagard®-720 EpoCem @ 2 kg/Sqm/mm thickness having Compressive strength > 35 N/mm2 (14 days) as per IS 9162-79 complete all as specified and directed
OVERHEAD TANK TREATMENT Chipping of cement sand mortar from the existing concrete surface or as per site requirement by chieseling and disposal of malwa from site as per instruction of Engineer-in-charge. Note :- During execution of repairing work of RCC water tank , additional arrangement for water supply for the hospital services has to be keep in view by AGE E/M (W/S)
M&L for Providing and applying cement-based epoxy-modified three component anti corrosive coating and bonding slurry SikaTop®-Armatec 110 EpoCem® slurry @1.2 – 1.5 kg/m2 as a bonding coat on prepared surface. Bond strength wet on Wet: >10 N/mm2 (14 days moist cure plastic concrete to hardened concrete) as per ASTM C 882
M&L for Providing and applying 12 mm thick layer of Sika MonoTop®-412 (IN) single component, fibre reinforced, sulphate resistant, low shrinkage, high performance cementitious structural repair mortar conforming to EN 1504-3 Class R4 on exposed concrete surface as per technical specification. Material should have Compressive strength ≥ 55 MPa as per EN:12190, Chloride ion content ≤ 0.05% as per EN:1015-17, Adhesive bond ≥ 2.0 MPa as per EN:1542, Carbonation resistance dk ≤ control concrete [MC(0,45)] as per EN:13295 & Elastic modulus ≥ 20.0 GPa as per EN:13412. (Complete finished item with all leads and lifts) complete all as specified and directed
Supply and apply two coats of SikaTopseal 107 @ 1.5kg/per coat or equivalent, a two components ready to use polymer modified cementatious coating certified for portable water in three coats with glass fiber mesh of =>45 GSM . The thicknessof coating shall not be less than 1.5mm System should have compressive strength: 20 N/mm2; bond strength: 2.0 N/mm2 complete all as specified and directed
Applying three coats Sikagard67 or equivalent, a water based epoxy coating certified for portable water on all over the concrete surface from inside. The coating shall be applied using roller brush application complete all as specified and directed
Description of Work / Item(s)
Amount
Taking down cement plaster of any description on brick or concrete surfaces of walls or ceiling etc incl. raking out joints ,hacking for key and scrubbing down with water complete all as specified and directed
Demolition of reinforced cement concrete in beam, staircase, landing chajjas and similar work of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of brick work built in CM incl all quoins, pillars etc but excl ashlar facings, dressed stone work and precast concrete complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
Taking down or steel water tubing along with fittings connections incl cleaning for reusing or removing 15 mm bore complete all as specified and directed
Taking down or steel water tubing along with fittings connections incl cleaning for reusing or removing 20 mm bore complete all as specified and directed\
Demolition of plain cement concrete (unreinforced) of any description and any position not otherwise provided complete all as specified and directed
Taking down Chowkats or frames with shutters without taking off shutters from frames not exceeding 1.50 Sqm each complete all as specified and directed
All as per item No 8 here-in-before but exc. 1.50 but n. exc. 4 sqm each
M&L rendering 15 mm thick cement mortar 1:3 mixed with water proofing compound on fair faces of concrete surfaces finished even and smooth without extra cement for sunken slab complete all as specified and directed (Note :- WPC shall be measured and paid separately)
M&L PCC 1:5:10 type E-2 (using 40mm brick aggragate)for filling in sunken floor complete all as specified and directed
M&L 40mm thick PCC type B-1, 1:2:4 (uisng 20mm graded stone aggregate) as in floorng complete all as specified and directed
M&L for filling of sunken floors by cinder aggregate conform to IS 2686 : 1977 - Cinder aggregate shall be class A of well burnt furnace residue obtained from furnaces using only coal as fuel. It shall be clean and free from clay, dirt, wood, ash or other deleterious matter for filling in sunken floor of toilets.
Supply and fix Factory made wood grain solid PVC moulded door with particle board core shutter 28 to 30mm thick (stiles) with 2,4, or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, fixing in frame at site as per specification complete all as specified and directed.
S&F Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life)
S&F 100 mm long butt hinges medium weight mild steel alloy with galvanised .
S&F of 100mm long aluminium handles, cast type stove enamelled black complete all as specified.
S&F in repairs bib taps, cast copper alloy, fancy type with crutch or butterfly handles, chromium plated, screwed down to iron pipes or for brass ferrule of 15 mm bore complete all as specified.
S&F in repairs stop valves, cast copper alloy, fancy type, chromium plated with long shank & cup (concealed type) with crutch or butterfly handle, screwed both ends for iron pipe of 15 mm bore complete all as specified.
S&F in repairs stop valves, cast copper alloy, fancy type, chromium plated with crutch or butterfly handle, screwed both ends for iron pipe of 15 mm bore complete all as specified.
S&F in repairs pillar taps cast copper alloy chromium plated, with capstan heads screwed down, high pressure with or without lettered hot or cold with long screwed shames and fly nuts, screwed for 15 mm bore pipe complete all as specified.
S&F in repairs chromium plated shower rose 125 mm size with or without swivel joints complete all as specified.
S&F in repairs CP Towel rail 450mm long fixed with and including chromium plated brass screws and wooden/plastic cleats complete all as specified
S&F in repairs soap dish, vitreous china white approximate size 160x160x90mm fixed to plugs with chromium plated brass screws etc complete all as specified
S&F chromium plated jet for WC with 1.00 mtr long pvc pipe incl necessary GI fittings as required like toe, nipple etc all as specified.
S&F of glass shelf assembly consisting of 5.5 mm thick sheets glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified
M&L Aluminium anodised coloured powered coated frame work as in partition wall/door /chawkhats/ window shutters/ deco grills using any suitable section conforming to IS-733 and IS-1285 amd coating grade A-153 confirming to IS-1868 fixed with rawl plug and screw or with fixing clips with expansion hold fasteners including necessary jointing cleats, glazing clips, rubber packing anodised aluminium map beading packing anodised aluminium map beading screws, anodised aluminium fittings etc gap of junction at top, bottom & slides filled with PVC/Neoprene felt, handles etc complete all as specified.
S&F aluminium powder coated Grill (DECO grill DG 103 of 10mm thick of M/s ELESAR, M/s Royal Grill, M/s National Grill Associated profiles & Aluminium Ltd) fixed with suitable 'F' section (No 8584) 15.30 X 23.40 X 1.40mm (minimum), fabricated and riveted to aluminium window/ventilator complete all as specified and directed.
S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed.
S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aparture 1.18 mm and fixed with tinned tacks or galvanised wire stapples complete all as specified and directed
S& F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire(annealed) not less than 0.9mm dia complete all as specified and directed
All as per item no 30 here-in-before but 6 to 8mm dia, as in stirrups, spacers and binders.
Cutting chases, pining in, making good to faces where required in CM 1:3 for lintels/Chajjas shelves etc in brick work exceeding 10cm girth but not exc 20cm girth complete all as specified and directed
Material and labour for brick work using sub class 'B' bricks in CM 1:6 straight or curved on plan exc. 6m mean radius complete all as specified and directed
M&L for 15mm thick ready mix plaster on brick or concrete surfaces of walls finished even and smooth complete all as directed and specified.
M/L for 12 mm thick ready mix plaster on brick or concrete surfaces of walls finished even and smooth complete all as specified and directed.
M/L for 10 mm thick ready mix plaster on brick or concrete surfaces of walls finished even and smooth as in ceiling complete all as directed and specified.
M&L for RCC (Nominal Mix) 1:2:4 type B1 (using 20mm graded stone aggregate) as in chajjas, beams and similar work complete all as specified and directed
M&L for form work to chajjas, weather shades, corbels, chullah hoods and similar items including edges, work in rough finished flat surface of concrete complete all as specified and directed
M&L for form work edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 5cm but n exc 10cm incl fair finish complete all as specified and directed
M/L for preparation of new plastered surface of walls and applying two coats of cement base paint over a coat of primer complete all as directed and specified.
M&L for Mild Steel framed work as in rungs in shafts/ grill/grating guard bars etc ends of bars shouldered and or reverted/fixing with fastner complete all as specified and directed by Engr-in -Charge.
M&L for preparation of old surface and applying one coat of white wash on ceiling all as directed and specified.
M&L for preparation of new surface and applying three coat of white wash on ceiling all as directed and specified.
M&L for preparation of old surface and applying one coat of distemper on wall complete all as directed and specified.
M&L for preparation of old surface and applying two coat of distemper on wall complete all as directed and specified.
M&Lcomplete removal of existing treatment for preparation of old surface and applying two coat of distemper on wall complete all as directed and specified.
Supplying and laying of CPVC pipes OF 16mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
All as per item No 48 here-in-before but 20mm outer dia
S/F in repairs 100 mm dia cast iron soil waste pipe sand cast pipes and vent pipe in any length with or without ears with cement joints fixed to walls/floors etc complete all as specified and directed
S/F in repairs 75 mm dia cast iron soil waste pipe and vent pipe in any length with or without ears with cement joints fixed to walls/floors etc complete all as specified and directed
S/F in repairs CI floor trap incl jointing to waste pipe in run lead with dia of out let 75 mm complete all as specified and directed
S/F in repair bends any radius diminishing -pieces or taper 100 mm dia complete all as specified and directed
S/F in repair bends any radius diminishing -pieces or taper 75m m dia complete all as specified and directed
S/F of branch pieces, single(equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches for 100 mm diacomplete all as specified and directed
S/F of branch pieces, single(equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches for 75 mm dia all as spfd and directed
S/F PVC connection 15 mm dia with PTMT nut of length 450mm complete all as specified and directed.
S/F fixing in repairs vitreous china squatting (Orissa pattern) water closet size 580X440 with integral foot rests ( excluding flushing cistern and flush pipe) complete incl. connection to trap and flush pipe anti syphonage pipe etc complete all as specified and directed.
S/F in repairs vitreous china wash down water closet pan (Pedestal pattern) excluding fixing floats, flushing cistern and flush pipe and including P or S trap etc complete all as specified and directed
M&L for pvc low level flushing cistern with inlet,valve wall ,float and handle encluding brackets, and connections to pipes as in repair complete all as specified and directed
M&L for flush pipe to squat pattern closet including all joints and making good to the floor as in repair complete all as specified and directed
Supply only integral water proofing compound complete all as specified and directed
M&L for non-skid ceramic coloured tiles tiles 7 to 8mm thick(square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar (1:6) complete all as specified and directed
M&L for glazed ceramic cloured / printed tiles in vertical surfaces area of each tiles 300 mm X 450 mm and 7-8 mm thick set and jointed in neat cement slurry including 10mm thick screed in cement 1 :4 and pointed in white or coloured cement to match the shade complete all as specified and directed.
S&F PVC (SWR) pipes 150 mm dia and 5mm thick single socketed, in any length with solvent cement joints fixed to walls/laid in floors incl stack clamps of stainless steel with bolts & nuts etc .
S&F PVC SWR bends 150 mm.dia and 5mm thick complete all as specified and directed
M/L for one coats synthetic enamel paint on old steel surfaces of any description not otherwise described over 10 cm width or girth including prepartion of surfaces complete all as specified and directed
M&L for two coat of synthetic enamal paint over a coat of primer on steel surface exc 10cm in girth, complete all as specified and directed.
S&F ABS soap dispensors of 1.0 lit capacity complete all specified and directed by Engineer-in-charge make- Euronics Cat No-ES-03
S & F ABS body tissue paper holder of size 385 x 280x 115mm complete all as specified and directed make- EP 03 of Euronics
S & F 12 mm thick frosted toughened glass urinal partition including stainless steel brackets etc fixed in position complete all as specified and directed.
S/F grating square 150mm size of PTMT with hole or without hole complete all as specified and directed.
S/F in repair brass cromium plated bottle traps 32mm bore for wash basin with inlet and outlet screwed for pipe or connections including necessary packing , union and cap etc complete all as specified.
S&Fin repair PVC telephonic jet with all fitting and fixture for EWCs all as specified and directed
S/F in single lever basin mixer with popup waste system and 450 mm long braidaed hoses chromium plated of Make- ORM-10051 B of Jaquar or Equvlentfoer pipes etc incl CP wall flange of same make.
S/F in repair single lever basin mixer with popup waste system and 450 mm long braidaed hoses chromium plated of Make- ORM-10051 B of Jaquar or Equvlentfoer pipes etc incl CP wall flange of same make.
S/F in single lever wall mixer with provision for over head shower with hand pipe on shower side , connectiong legs and wall fittings complete of Make- ORM-10143N of Jaquar or Equvlentfoer pipes etc.
S&F in repairs vitreous China white urinal flat back of size 600 to 680mm x 430mm x 370mm with 32mm dia CP casted bottle trap, 32mm dia brass CP dome waste, 32mm dia brass CP spreader union for discharge pipe 32mm complete with necessary fittings.
S&F of SS (Gd-304) brackets, angles, hollow tubes, flats etc of any shape and size with & including SS screws / fasteners etc and all kind of machine works i.e. cutting, welding, bending, moulding, grinding, polishing, buffing etc to get the required shape and size, fixed to any position and at any surface etc, complete all as directed. (Note : All fixtures and fittngs should be of stainless steel)
S&F of stainless steel sink, 1.00 mm thick for kitchen or laboratory with plug, waste pipe, washers, including mild steel brackets, connecting union etc overall approx size 550 mm x 450 mm with approx bowl size of 500 mm x 375 mm x 200 mm etc, complete all as directed.
Sunken slab treatment Cleaning of RCC surface to remove dust, loose particles, etc with compressed air or any other suitable technique depending on site conditions, grinding any sharp edges, etc
Waterproof Sealing arround perimeters & wall to floor junction with Sika® Seal Tape-S special tape ,made of thermoplastic elastomer reinforced with polyester woven fabric for waterproof sealing around perimeters and joints in wet tiled areas specially designed for wet room.
M&L for sealing of pipe penetration of toilets core cutting in the following stages:- Supply and apply solvent free, moisture insensitive epoxy resin based patch repair putty on pipe penetration surfaces. The putty shall be applied to a groove thickness of minimum 20mm on pipe penetration joint to concrete Product: Sikagard®-694 F (I), Yield: 0.6 ltr/kg. Product requirements: suitable for submerged condition; compressive strength of 40 N/mm2 (1 day) according to IS 9162-1979.
Supply and apply a glass fibre reinforced acrylic modified cementitious coating system.Prepration of surface of sunken portion and M & L for glass fibre reinforced acrylic modified cementitious coating system as Top coat: SikaTop® Seal-107 @ 1.5 kg/m2 over reinforcement: Sika® Fab-1 over base coat: SikaTop® Seal-107 @ 1.5 kg/m2 etc all as specified and directed. System should have compressive strength: 20 N/mm2; bond strength: 2.0 N/mm2.
On the horizontal surfae :Supply and apply a protection screed 1:2:4 in 50 mm thickness laid to be admixed with integral waterproofing compound Sika® Plastocrete Plus confirming to IS 2645 at the rate of 0.10 kg per bag of cement.
On vertical surface: Supply and apply a protection plaster (12 – 15 mm) admixed with appropriate integral waterproofing compound Admixture: Sika® Plastocrete Plus @ 0.10 kg per bag of cement. Product requirements admixture: conforms to IS 2645 complete all as specified and directed
Description of Work / Item(s)
Amount
M&L for taking down old unserviceable point wiring from existing surface/concealed conduit after disconnection of electric connection from main DBs (light, fan, socket or power point) complete such as switches, ceiling rose, pendent holder, regulator and socket etc and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original existing surface i.e. brick work, plastering, white colour washing complete all as directed by Engr-in Charge.
All as per srl item No. 02 here in before but point wiring for one socket outet point 5 amps on the same board.
All as per srl item No. 02 here in before but point wiring for one socket outet point 5 amps on the independent board.
All as per srl item no. 02 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp power point on Independent board.
Material and labour in replacement of Sub main wiring with 2 run of 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including cutting and chasing,and also PVC conduit suitable dia as per SSR part-I with medium grade including 4.0 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB complete all as directed. Note : 1. The two run of 4 Sqmm wire, one run of 4 Sqmm wire and 1 run of PVC conduit will be measured as one unit.
All as per srl item no. 6 here-in-before but with 2 run of 6.0 sq mm FRLS copper wire with 4.0 Sqmm FRLS copper cable as earth wire.
All as per srl item no. 6 here-in-before but with 2 run of 10.0 sq mm FRLS copper wire with 10.0 Sqmm FRLS copper cable as earth wire.
Supply & fixing in replacement of Modular switch 6 Amp, 1 way, 1 module size complete all as directed.
Supply and fixing in replacement of Modular switch 16 Amp, 1 way, 1 module size complete all as directed.
Supply and fixing in replacement of Modular socket 6 Amp, 3 pin, 2 module size complete all as directed.
Supply and fixing in replacement of Modular socket 6/16 Amp, 3 pin, 2 module size complete all as directed.
Supply and fixing in replacement of Modular Fan regulator step type, 100 watts, 1 Module size complete all as directed.
Supply and fixing in replacement of Ceiling rose, PVC polycarbonate body isolated body, 3 terminal, 240 volts complete all as directed.
Supply and fixing in replacement of MCB protected modular AC/Geyser box 3 module complete with and including 6 pin socket 25 amps, plug top, modular cover plate, mini MCB SP 25 Amp C Curve capacity and PVC gang box etc, complete all as directed.
M&L for earthing complete in replacement with galvanized steel earth plate electrode 60cmx60cmx 6 mm thick burried directly in ground, earth pit not less than 2.25 Mtr deep and top edge of plate not less than 1.25 mtr below ground level and connected to GI earth lead wire 4 mm dia fixed by means of nuts bolts etc including light grade GI pipe 15 mm dia bore for protection of GI wire 4mm dia, connected to earth test point surrounded by packed alternative layers of charcoal and common salt 15 cm thick all around top, GI pipe 20 mm dia with GI funnel and bottom complete all as shown in plate No 3 to the earthing test point all as specified and indicated including provn of PCC chamber 1:3:6 using 20mm graded stone aggregate, 50mm thick cover with RCC 1:2:4 type B-1 using 8 mm dia TMT bars @ 100 mm C/C both ways as in reinforcement, necessary excavation, earthwork, returning filling and testing on completion etc all as specified and directed.
Supply and fix in replacement bed head light fitting including 1x10 Watt LED, 1x20 watt LED, 1x5 watt LED lamp made of powder coated CRCA sheet & acrylic cover including 2 metre lenth of pendent with 03 Nos switches for each light complete all as directed.
S&F in replacement LED tube light fitting 20 watt (CW) , 4 feet long in extruded aluminium batten with high efficient LEDs available in milky diffuser and Color Rendering Index (CRI>70), IP20, correlated Color Temparature (CCT- 5700K to 6500K) , PF>0.9 and Voltage rated 220V to 240V complete all as directed.
S&F in replacement of recessed mounting LED light fitting (flat panel) 2' x2' with high efficeint LEDs and Glare free and opal diffuser of 36 watt (CW) including fixing accessories likes strip clips etc and Color Rendering Index (CRI>70), IP20, correlated Color Temparature (CCT- 5700K to 6500K) , PF>0.9 and Voltage rated 220V to 240V etc
S&F in replacement recessed/surface mounted LED light fitting 6 watt(CW/WW) slim round down lighter with high efficient LEDs and glare free opal diffuser including fixing accessories likes strip clips includding connection copper cable from celining rose to fittings 0.75 sqmmx 3coreand Color Rendering Index (CRI>70), IP20, correlated Color Temparature (CCT- 5700K to 6500K) , PF>0.9 and Voltage rated 220V to 240Vetc complete all as directed.
S&F in replacement recessed/surface mounted LED light fitting 15 watt(CW/WW) slim round down lighter with high efficient LEDs and glare free opal diffuser including fixing accessories likes strip clips and Color Rendering Index (CRI>70), IP20, correlated Color Temparature (CCT- 5700K to 6500K) , PF>0.9 and Voltage rated 220V to 240V etc complete all as directed.
S&F in replacement recessed/surface mounted LED light fitting 18 watt(CW/WW) slim round down lighter with high efficient LEDs and glare free opal diffuser including fixing accessories likes strip clips includding connection copper cable from celining rose to fittings 0.75 sqmmx 3coreand Color Rendering Index (CRI>70), IP20, correlated Color Temparature (CCT- 5700K to 6500K) , PF>0.9 and Voltage rated 220V to 240V etc complete all as directed.
M&L for painting of ceiling fan complete with synthetic enamel paint by spraying including filling cavaties with filter one coat after cleaning all as directed
Fixing only with accessries celing fan and connecting with and including 3 core flexible copper cable from ceiling rose to fan all as directed
Taking down carefully and any type of fire alarm detectors from ceiling and re-fixing on same position with cleaning and tested complete all as directed.
S&F in replacement Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, flushed mounting, SPN 12 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc and making all necessary connections, incl cutting & chasing and making good the surface as per existing complete all as directed. Note: MCBs shall be measured and paid seperately.
All as srl item no 26 here in before but 8 way type SPN.
All as srl item no 26 here in before but SPN 04 way type.
S&F of MCB in replacement C curve type, 10 kA, 6-32 Amp, single pole, 10 KA with over load and short circuit protection complete all as directed.
All as srl item no 29 here-in-before but of 40-63 amps capacity SPN type, 10 KA.
M& L for wire less display unit for OPD dactors door with radio frequency attenuation filter, display 3 digit 2.5 " high bright red colour frequency 433 MHZ radio operated, dial number display , audio anouncment next patient please, power 12 volts DC. Make :- RD Plast/Honeywell/Process data care
M& L for wire less calling unit ( PAD FOR for OPD dactor's) with radio frequency attenuation filter, display 3 digit, frequency 433 MHZ radio operated, dial number display size .56" audio anouncment next patient please power 12 volts DC. Make :-RD Plast/Honeywell/Process data care
M& L for wireless , display system ( for waiting area) for six OPD's in a display Make :- RD Plast/Honeywell/Process data care
Supply and fixing air circulator fan single phase 230 volts, Oscillating 450 mm sweep suitable for wall mounting Make :- RD Plast/Honeywell/Process data care
S&F metal body exhaust fan (5 Star rating) 300 mm sweep, 230 volts, single phase 1400 RPM with copper wound and louvers including necessary electric connection with appropriate size of PVC copper wire from ceiling rose to exhaust fan complete all as specified and directed. Make. : Bajaj, Heavells, Usha, Crompton
Taking down carefully existing aluminium /GI strip with air termination rod of any size fixed in position as lightning conductor from roof/wall and buried in ground including making good the disturbed surfaces etc complete all as specified and directed by the Engineer-in-Charge.
Refixing only aluminium/GI strip and air termination rod of any size after necessary repairs (like removing denting/bend rejoining tightening properly by GI bolts and nuts securing, tightly by MS clamps of suitable size for roof/conductor/down conductor above ground level including jointing properly by existing GI/Aluminium strips, air termination rod and insulators) complete all as specified and directed
Dismantling carefully cable of any type/size from panel/LT feeder pillar box/ transformer etc & taking out from roop/ wall/ shafts/ trenches etc and shifting where as directed. The alternative cable connections shall be made for uninterrupted power supply to the Hospital without any extra cost complete all as specified and directed.
Relaying the cable of any type/ size on roop/ wall/ shafts/ trenches by proper fixing accessories and Reconnecting the cable ends of any size to panel/LT feeder pillar box/transformer etc with suitable lugs & preparing fresh terminals complete including excavation of loop & refilling complete all as specified and directed.
Description of Work / Item(s)
Amount
Material and labour in replacement of Sub main wiring with 4 run of 10 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including cutting and chasing,and also PVC conduit suitable dia as per SSR part-I with medium grade including 10 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB complete all as directed. Note : 1. The 4 run of 10 Sqmm wire, one run of 10 Sqmm wire and 1 run of PVC conduit will be measured as one unit.
All as per srl item no. 1 here-in-before but with 2 run of 4.0 sq mm FRLS copper wire with 4.0 Sqmm FRLS copper cable as earth wire. Note : 1. The 2 run of 4 Sqmm wire, one run of 4 Sqmm wire and 1 run of PVC conduit will be measured as one unit.
All as per srl item no. 1 here-in-before but with 2 run of 6.0 sq mm FRLS copper wire with 6.0 Sqmm FRLS copper cable as earth wire. Note : 1. The 2 run of 6 Sqmm wire, one run of 6 Sqmm wire and 1 run of PVC conduit will be measured as one unit.
M&L for DLP PVC tranking including all accessories i.e band tee, end cap etc of size 80 x50 mm complete all as specified and directed. Note :- Make for item No 4 to 8 shall be same.
Supply & fix Full cover suitable for PVC DLP trucnking size 80x 50mm
S&F in replacement of modular socket 6/16 Amps , 3 pin,3 module size complete all as directed
S & F modular switch 16 switch 16 amps, 1 way, 1 module size suitable for DLP tranking complete all as directed.
S & F white cover plate with frame 4 modular sutaible for DLP tranking complete all as directed .
S&F in replacement Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, flushed mounting, SPN 12 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc and making all necessary connections, incl cutting & chasing and making good the surface as per existing complete all as directed. Note: MCBs shall be measured and paid seperately.
All as srl item no 9 here in before but 8 way type SPN.
M&L for intenal & external angles adjustable from 80 to 90 degree for DLP trunking of size 80x80mm complete all as specified and directed
M&L for left & right end cap DLP PVC tranking of size 80x50mm complete all as specified and directed
S&F MCB C Curve type, 10 KA, 6-32 Amp, single pole, with over load and short circuit protection complete all as specified and directed
All as per Srl item No 13 here-in-before but 40-63 Amp capacity SPN type, 10 KA
All as per Srl item No 13 here-in-before but 63 Amp capacity TPN type, 10 KA
Description of Work / Item(s)
Amount
Taking out old unserviceable Pump motor after disconnected all fittings and electrical connection of capacity 25 HP from foundation of any make and typed incl demolation of pump foundation and deposited to MES yard complete all as directed.
Supply & installation testing and commisioning of electric driven induction motor with pump of capacity 18.5kw/25 HP 415 volt 3 Phase 50 Hz 1475 RPM end suction type 80/100, total head 45mtr and discharge 1500 LPM casing and impeller madeout of gun metal and stainless steel shaft stuffing box seal gland packed and base frame of MS febricated and incl suitable bend, elbow, washer, nuts, bolt, studs, thimbles incl all types of cutting / threading / welding works making all connection to the delivery and suction pipeline including replacement of old rusted parts / components of distribution / suction pipe line for smooth functioning of water supply including foundation of pump motor with alignment and suitable PCC of 1:2:4 type B1 using 20mm stone aggregated all as directed. Make : kirloskar/ABB/CG including S&F install and testing of Soft starter suitable for 18.75 KW 42 Amps at 40 degree C CAT No CSX1018V4C1 in L&T, 3 phase 415 Volts with MCCB 63 Amps 25 KA TP, making space in exiting panel for smooth operation complete all as directed.
S&F CI foot valves, without bypass arrangement, vertical installation, flanged type with gasket for iron pipe of 100 mm bore as per IS 4038 complete all as directed. Make:Kirloskar,kartar
M&L fixing the CI Sluice valve of 100mm PN 1.6 as per IS;14846 including CI flange with gaskit complete all as specified. Make:Kirloskar,kartar,zoloto
Supply and fix cast iron non return valve as per IS W5312 Part-I of 100mm bore including nuts, bolts, gasket, flanged complete all as directed. Make:Kirloskar,kartar.
Supply and Laying & fixing cable PVC insulated screened meter PVC bedded Galvanised steel Strip or wire armoud electric power cables(heavy duty)1100 Volts grade with stranded copper conductor of size 10 Sqmm 3 core complete all as directed Make:- Havells/Polycab/L&T
Dismantling/taking out to old unsv GI/CI pipe line from wall/floor, cleaning the same and re-fixing the pipeline after roof treatment with complete fittings of following sizes. (Note : (i) During the dismantling of the pipeline if there is any damage or leakage to the fittings and valves like gate valves, sluice valves, float vale nipple, socket, tee, elbow, union etc then contractor should replace the same at their end only. (ii) Contractor should arrange an alternate arrangement for water supply till the original line is repaired at their end). (a) 20 MM dia GI
(b) All as per Srl item No 7(a) here-in-before but 25 mm dia
(c) All as per Srl item No 7(a) here-in-before but 40 mm dia
(d) All as per Srl item No 7(a) here-in-before but 50 mm dia
(e) All as per Srl item No 7(a) here-in-before but 80 mm dia
(f) All as per Srl item No 7(a) here-in-before but 100 mm dia
(g) All as per Srl item No 7(a) here-in-before but 150 mm dia
(h) All as per Srl item No 7(a) here-in-before but 32 mm dia
S&F GI water tubing medium grade (ISI marked) laid in wall/floor incl fittings as required as per site and including jointing internal as specified of size :- (a) 20 MM dia GI
(b) All as per Srl item No 8(a) here-in-before but 25 mm dia
(c) All as per Srl item No 8(a) here-in-before but 40 mm dia
(d) All as per Srl item No 8(a) here-in-before but 50 mm dia
(e) All as per Srl item No 8(a) here-in-before but 80 mm dia
(f) All as per Srl item No 8(a) here-in-before but 100 mm dia
(g) All as per Srl item No 8(a) here-in-before but 150 mm dia
Taking down carefully existing solar flat plate collector including its connected accessories like MS framed structure, GI piping system with/without insulation and fixing the same at its original position along with its accessories etc after roof treatment without any damage complete all as directed by Engineer-in-Charge. Note: If, any kind of damage is occurred to flat plate collector or any other services, due to negligence or poor workmenship of contractor, the same will be repaired/replaced by the contractor free of cost and no extra payment will be made in this effect to the contractor.
Taking down carefully existing solar hot water tank of capacity 10,000 Ltrs including its connected accessories like piping system with/without insulation, electrical system and fixing the same at its original position along with its accessories etc after roof treatment without any damage complete all as directed by Engineer-in-Charge. Note: If, any kind of damage occurred to Solar Hot water tank or any other services, due to negligence or poor workmanship of contractor, the same will be repaired/replaced by the contractor free of cost and no extra payment will be made in this effect to the contractor.
Description of Work / Item(s)
Amount
Supply, installation, testing and commissioning of water cooled Screw chillers with sliding type capacity control, comprising of one or multiple semi hermetic/hermetic compressors, flooded evaporator, shell and tube condensor, suitable expansion device, suitable for operation on R-134a refrigerants and of nominal capacity 350 TR. the chiller unit shall conform to energy efficiency requirement of ECBC +norms of ECBE-2017 complete all as specified and directed
Supply, installation, testing and commissioning of double skin unit floor mounted Air handling Unit 6 rows deep cooling and 2 row deep heating coil of minimum capacity 6 TR, 2000 CFM campatible with VFD, adequate capacity UV lamps complete all as specified and directed
All as per above item No 4 here-in-before but of minimum capacity 9 TR, 4000 CFM
All as per above item No 4 here-in-before but of minimum capacity 5.5 TR, 2000 CFM
All as per above item No 4 here-in-before but of the minimum capacity 13 TR, 4500 CFM
All as per above item No 4 here-in-before but of minimum capacity 14 TR, 5000 CFM
All as per above item No 4 here-in-before but of minimum capacity 13 TR, 4500 CFM
All as per above item No 4 here-in-before but of minimum capacity 5 TR, 2200 CFM
All as per above item No 4 here-in-before item but of minimum capacity 4.2 TR, 2550 CFM
All as per above item No 4 here-in-before but of minimum capacity 6 TR, 2800 CFM
All as per above item No 4 here-in-before but of minimum capacity 13 TR, 7600 CFM
All as per above item No 4 here-in-before but of minimum capacity 10 TR, 3500 CFM
All as per above item No 4 here-in-before but of minimum capacity 27 TR, 5000 CFM
All as per above item No 4 here-in-before but of minimum capacity 28 TR, 10680 CFM
All as per above item No 4 here-in-before but of minimum capacity 23 TR, 7130 CFM
All as per above item No 4 here-in-before but of minimum capacity 15 TR, 5000 CFM
Taking down of old UNSV Hot water Generator of capacity 800 KW with connected accessories at main air conditioning plant including and deposited to MES store yard complete all as specified and directed
Supply, Installation, testing and commissoning of Hot water generator of capacity 800 KW (80 KW x 10 Nos). complete all as specified and directed
Supply, Installation, testing and commissoning in replacement of electric driven induction motor with pump of capacity 37KW/50 HP 415 volt,3 phase 50 Hz,1475 RPM Model -DB 150/32 end suction type 150/200, Total Head 25.91 Mtr and discharge 88.38 LPS, casing and impeller madeout of cast iron and shaft 40C8, stuffing box seal gland packed and base frame of MS fabricated. Make:- KIRLOSKAR/BHARAT BIJLI/ABB
Supply, installation and Testing of online electrostatic scale off non chemical water treatment system with electrically operated control panel to be fixed on sub header suitable for 4x350TR Main AC Plant. The outer casing shall be of 304 grade stainless steel with both ends flanged and capable preventing scale formation. This shall be suitable for water flow rate 5250 LPM each dia of pipe 8"/200 MM in condenser circuit. The work includes cutting of existing GI/MS sub header and providing mild steel flanged heavy duty and joining with reducer, nut & bolts, gaskets at both ends with welding and modification in existing system complete as required. Electostatic scale off online chemical scale preventer system 'scale off' MODEL:-No.7033 by M/S Weldon Engineers (india). Make:Scale off/Hydrocon/Dolphin.
Supply, installation in replacement of check valve of size 200 mm with insulation. The chilled valves shall be insulated with Aluminium faced Nitrile rubber of thickness 25mm complete all as specified and directed
Supply, installation in replacement of Y Strainer of size 200 mm with insulation. The chilled valves shall be insulated with Aluminium faced Nitrile rubber of thickness 25mm complete all as specified and directed
Supply, installation in replacement of Balancing valve of size 200 mm with insulation. The chilled valves shall be insulated with Aluminium faced Nitrile rubber of thickness 25mm complete all as specified and directed
Supply, installation in replacement of pressure gauge dial type 0-14 Kgs rating complete all as specified and directed
Supply & fixing in replacement of temperature gauge bottom connected, direct mounted type, of temperature range of 0 - 100°C or 32 - 212°F, complete all as directed. Make : H-Guru / Fiebig / Wika
Supply & installation in replacement of flow switch including taking down old flow switch complete all as specified and directed
Supply & installation in replacement of auto air vent 10 mm including taking down old air vent complete all as specified and directed
Supply, installation, testing and commissioning of GSS Duct of 22 Gauge including taking down old duct complete all as specified and directed
Supply and fixing canvas connection from AHUs to supply and return duct including taking down old canvas all as directed by Engineer-in-charge.
Supply and fixing of thermal insulation on Duct with nitrile rubber 15 mm thick.
Supply and lay MS pipe pipe in replacement 20 mm bore heavy grade with all fittings laid in floors or ffixed to walls and ceiling including taking down old pipe alongwith accessories etc complete all as specified and directed by Engineer-in Charge. Make - Tata Steel / Jindal Steel / Electrosteel / Jai Balaji.
All as per item No 33 here-in-before but for pipe size of 25 mm dia.
All as per item No 33 here-in-before but for pipe size of 32 mm dia.
All as per item No 33 here-in-before but for pipe size of 40 mm dia.
All as per item No 33 here-in-before but for pipe size of 50 mm dia.
All as per item No 33 here-in-before but for pipe size of 65 mm dia.
All as per item No 33 here-in-before but for pipe size of 80 mm dia.
All as per item No 33 here-in-before but for pipe size of 100 mm dia.
All as per item No 33 here-in-before but for pipe size of 125 mm dia.
All as per item No 33 here-in-before but for pipe size of 150 mm dia.
All as per item No 33 here-in-before but for pipe size of 200 mm dia.
M&L in replacement of Insulation for M S pipe with PUF slab 30 mm thick with and including applying bituminous compound and GI cladding with 26 guage GI sheet including taking down old insulation complete of size 20 mm dia all as directed.
All as per item No 44 here-in-before but of 25 mm dia
All as per item No 44 here-in-before but of 32 mm dia
All as per item No 44 here-in-before but of 40 mm dia
All as per item No 44 here-in-before but of 50 mm dia
All as per item No 44 here-in-before but of 65 mm dia
M&L in replacement of Insulation of M S pipe with PUF slab 40 mm thick with and including applying bituminous compound and GI cladding with 26 guage GI sheet including taking down old insulation complete of size 80 mm dia complete all as directed.
All as per item No 50 here-in-before but of 100 mm dia
All as per item No 50 here-in-before but of 125 mm dia
All as per item No 50 here-in-beforebut of 150 mm dia
All as per item No 50 here-in-before but of 200 mm dia
Supply, and fixing in replacement of cast Iron butterfly valve, ISI marked, PN - 1.6 pressure grade, having Nitrile/EPDM rubber lining, SS stem, CS/SS disc. Lever operated type, of size 50 mm dia bore with hand wheel including all jointing material i.e, nut, bolt, washer, packing material etc, duly insulated and taking out of old unserviceable valve, complete all as directed. Make: Advance/Audco/Leader/Castle/NVR/Sant.
All as per item No 55 here-in-before but bore size of 65 mm.
All as per item No 55 here-in-before but bore size of 80 mm.
All as per item No 55 here-in-before but bore size of 100 mm.
All as per item No 55 here-in-before but bore size of 125 mm.
All as per item No 55 here-in-before but bore size of 150 mm.
All as per item No 55 here-in-before but bore size of 200 mm.
Supply and fixing non return valve PN- 1.6 IS 5312 Part -I. 150 mm dia both ends flanged heavy duty including packing materials, nut bolts washer etc and testing complete including taking out of old U/S non return valve all as directed. Body Cover CI IS : 210, Gr. FG260. Body Rings - Bronce : IS 318 Gr. LTB2. Hinge Pin-SS ASTM A276 Type 410. Flage Drilling - IS 1538, Table 4 & 6. Make: VENUS/KIRLOSKAR/Castle/Sant Valve
M & L in replacment of unserviceable 2/3 way modulating motorized valve (glow type),GI globe body,Brass seating,SS-304 spindle ,Telflon gland,with linear movement actuator 24 V AC input supply,0-10Vinput signal with modulating thermostate & transformer of size-25 mm Model VXP 45.25 SSC 61 + ALG 253 Make:-SIEMENS/RAPID CONTROL/RAPID COOL
All as per item No 63 here-in-before but model VXP 45.32+ SSC 61 + ALG 323 size 32 mm bore
All as per item No 63 here-in-before but model VXP 45.40+ SSC 61 + ALG 403 size 40 mm bore
All as per item No 63 here-in-before but model VXF 31.5+ SKD 62 size 50 mm bore
All as per item No 63 here-in-before but model VXF 31.65+ SKD 62 size 65 mm bore
All as per item No 63 here-in-before but model VXF 31.80+ SKD 62 size 80 mm bore
All as per item No 63 here-in-before but size 5/8 inch bore.
Supply & installation in replacement of Thermostat, LCD display, with temperature display suitable for summer/winter season complete with cotrol wiring to connect with motorized valve and LT electric Panel board all as specified and directed Make - Seimens /Honeywell
Supply, installing, testing, and commissioning in replacement factory made and tested, indoor type, floor mounted , LT panel board, cubicle type, suitable for 415 Volts, 3 phase, 4 wire, 50 Hz, AC supply system having bus bar chamber with insulated copper bus bars of rating 3000 amps installed on procelain insulators. The panel shall be dust and vermin proof, IP - 54 class proctection and made of 16 SWG CRCA MS sheet and 40 X 40 X 6 mm thick MS Angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type, including internal wiring with PVC insulated solid, copper counductor cable, IS - 694 marked, 1100 volts grade of the following all as specified:-
(a) Incoming :-
(i) Air circuit beraker 2000 Amps TP&N 415 V, 50 Hz, AC supply, electrical draw out type, conforming to IS - 13118 having microprocessor based release for over current and earth fault, complete with racking inter lock and push lock and button - 02 Nos
(iii) Three Nos. CTs, of ratio 2000/5 amps, class I , VA burden 15 - 02 set
(v) Indicating lamps - 02 set of three
(b) Bus Coupler: 2000 Amps TP&N 415 V, 50 Hz, AC supply- 01 No
(c) Outgoing : -
(i) MCCB Adjustable type 4 pole, 630 amps, LT 415 Volts, 50 Hz AC grade and 50 KA rupturing capacity : 4 Nos (for chiller motor)
(ii) MCCB Adjustable type 4 pole, 800 amps LT 415 Volts, 50 Hz AC grade and 50 KA rupturing capacity : 4 Nos (for Hot water generator)
(iii) MCCB Adjustable type 4 pole, 125 amps LT 415 Volts, 50 Hz AC grade and 16 KA rupturing capacity : 08 Nos (for condensor / chiller water pump)
(iv) MCCB adjustable type TPN 63 amps, 10 KA rupturing capacity : 04 Nos ( for colling tower motor )
(v) MCCB adjustable type TPN 40 amps, 10 KA rupturing capacity : 02 Nos ( for hot water pump )
(i) The various feeders shall be indicated by 50 mm size letters written on white acrylic sheet and fixed on each switch with black, synthetic enamel paint.
(ii) A set of 3 Indicating lamps on each outgoing feeder
Supply and lay in replacement of LT XLPE cable Insulated screened Meter PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core, complete all as directed. Make - Havells/ KEI/ RR Kabel.
Supply and lay in replacement of LT XLPE cable Insulated screened Meter PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 sq mm 3.5 core, complete all as directed. Make - Havells/ KEI/ RR Kabel.
M&L for 50 mm bore gate valve cast copper alloy screwed down high pressure with handle screwed both ends for Iron pipe including taking out of old unserviceable gate valve complete all as directed. Make KIRAN/ LUSTER/ LEADER
All as per item No 75 here-in-before but size 40 mm bore
All as per item No 75 here-in-before but size 32 mm bore
All as per item No 75 here-in-before but size 25 mm bore
All as per item No 75 here-in-before but size 20 mm bore
M& L in replacment superior quality canvas cloth with Zip, Max cross sectional area 1 sqm having depth not more than 50 cm with GI frame suitable to connect both AHU and duct including taking down of old material all as per directed.
M& L for superior quality canvas cloth with Zip, Max cross sectional area 4 sqm having depth not more than 75 cm with GI frame suitable to connect both AHU and duct including taking down of old material all as per directed.
S&F in replacement of the MS Dampers with 20 gauge as per IS duly powder coated and as per existing size. The outlook crass section area of fresh air damper should be up to 0.8 Sqm ,fixed on wall with fresh air duct complete all as directed.
M&L Control desk / Remote to control the 57 nos AHU panel situated in various AHU rooms with copper control wiring and other accessories complete all as specified and directed
Material and Labour for Cement concrete in surface channels and drains type B2 1:2:4 ( 20 mm Graded stone Aggreagate) complete all as specified and directed
M&L for Earth continuity conductor or main earthing lead fix to wall on batten or recess or chases or burried in ground or drawn in conduit /pipe or fix to pole or any other indicated situation for loop earthing extra as required but size 32 x 6 mm galvanised iron strip complete all as specified and directed
M&L Earthig complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick, burried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised using galvanised iron strip 32x6mm as earthing lead by means of bolts, nuts, checks nuts and washers of galvanised iron of steel all as shown in electrical plate No 3 connect to earthing test point all as specified or indicatd including testing on completion.
Material and Labour in replacement of MS work, fabricated from MS channel, angle iron, flat iron of any size duly welded, including drilling of holes of suitable size with and including nuts, bolts and washers etc, as required and fixing the same on any level of the building, including painting with two coats of synthetic enamel paint over a coat of red oxide paint complete all as directed.
Supply and fixing in replacement of perforated, powder coated MS cable tray of size 1000 mm wide and 50 mm height including horizontal and vertical bends, reducers tees, cross members and other accessories as required and duty suspended from the ceiling with MS/Iron suspenders etc complete all as specified and directed.
All as per item No 88 here-in-before but of size 750 mm wide 50 mm height
All as per item No 88 here-in-before but of size 150 mm wide 25 mm height
All as per item No 88 here-in-before but of size 100 mm wide 25 mm height
All as per item No 88 here-in-before but of size 75 mm wide 25 mm height
AMIT ASSOCIATES
India Guniting Corporation
AMIT ASSOCIATES
LUMOS INFRA PVT LTD
LUMOS INFRA PVT LTD
India Guniting Corporation
India Guniting Corporation
AMIT ASSOCIATES
India Guniting Corporation
LUMOS INFRA PVT LTD
AMIT ASSOCIATES
India Guniting Corporation
India Guniting Corporation
LUMOS INFRA PVT LTD
AMIT ASSOCIATES
India Guniting Corporation
India Guniting Corporation
LUMOS INFRA PVT LTD
India Guniting Corporation
LUMOS INFRA PVT LTD
Bidder Name
AMIT ASSOCIATES
LUMOS INFRA PVT LTD
India Guniting Corporation
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid