Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹8.1 L+₹1.7 L (25.8%)Rejected-Finance NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance other than Lowest | |
| 3 | Rejected-Technical | - | Rejected-Technical No remarks in WLR CE Udhampur Zone QE Jun 2024 |
Tender Value
₹9.8 L
EMD Value
₹19,640
Closing Date
3 Sept 2024, 6:00 pmClosed
AGE (I) Bhalra
AGE (Indep) Bhalra PIN 900991 C/o 56 APO
SPECIAL REPAIR TO CARRY OUT REPAIR/REPLACEMENT OF OLD UNSERVICEABLE UNDERGROUND CABLE AND CERTAIN SANCTION WORK UNDER AGE (I) BHALRA
2024_MES_664379_1
AGE (I)/Bhalra- /2024-25 (NIT-09/2024-25)
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) Bhalra
Class E Category b i
8 documents required · 8 mandatory
₹500
AGE (I) Bhalra
₹19,640
Yes
15 Oct 2024
6 Jul 2024
10 Sept 2024
6 Jul 2024
3 Sept 2024
20 Jul 2024
Amount
Supply and fixing of electric water heater, storage type 25 ltr, BEE 5 Star rated, rust proof shock resistant ABS outer body with inner tank and heating element of capacity 2 KW with PUF Insulation designed to with stand 8 bar pressure complete with all accessories such as safety valve, thermostate, NRV, Indicator for power on and heating function including angle/stop valve and connection pipe for hot and cold water from angle/stop valve to geyser and necessary fixing arrangement by using suitable size fastener for fixing of geyser, complete all as specified and directed.
Supply and fixing of electric water heater, storage type 50 ltr, BEE 5 Star rated, rust proof shock resistant ABS outer body with inner tank and heating element of capacity 2 KW with PUF Insulation designed to with stand 8 bar pressure complete with all accessories such as safety valve, thermostate, NRV, Indicator for power on and heating function including angle/stop valve and connection pipe for hot and cold water from angle/stop valve to geyser and necessary fixing arrangement by using suitable size fastener for fixing of geyser, complete all as specified and directed.
Supply and fixing of electric water heater, storage type 100 ltr, BEE 5 Star rated, rust proof shock resistant ABS outer body with inner tank and heating element of capacity 3 KW with PUF Insulation designed to with stand 8 bar pressure complete with all accessories such as safety valve, thermostate, NRV, Indicator for power on and heating function including angle/stop valve and connection pipe for hot and cold water from angle/stop valve to geyser and necessary fixing arrangement by using suitable size fastener for fixing of geyser, complete all as specified and directed.
Material and labour for cutting of existing GI pipe two cuts and insertion of tee 15x15x15mm with nipples, unions and threading etc and making good disturb surface matching with existing area all as specified and as directrd.
Supply and fixing of 15mm bore Bib taps (ISI marked) of cast copper alloy chromium plated, fancy type, screwed down, high presure, screwed both ends for iron pipe or for brass ferrule, complete all as specified and directed.
Supply and fixing of 20mm bore Bib taps (ISI marked) of cast copper alloy chromium plated, fancy type, screwed down, high presure, screwed both ends for iron pipe or for brass ferrule, complete all as specified and directed.
Supply and fixing of 15mm dia GI steel water tubing, medium grade ISI marked, with and including all fittings such as bends, elbows, tees, short pieces, diminishing pieces, union etc complete to walls and ceilings or laid in floors complete all as specified.
Supply and fixing of 20mm dia GI steel water tubing, medium grade ISI marked, with and including all fittings such as bends, elbows, tees, short pieces, diminishing pieces, union etc complete to walls and ceilings or laid in floors complete all as specified.
Material & labour for Point wiring using FRLS PVC insulated unsheathed /multi stranded copper conductor cable 2.5 sqmm including 1.5 Sqmm FRLS PVC insulated unsheathed copper conductor earth wire drawn through and including concealed PVC conduit of appropriate size not less than 20 mm dia and 1.5 mm thick including all fittings viz tees, bend, junction box and pressed steel sunken box 60 mm deep & 1.6 mm thick duly painted inside and anticorrosive out side for mounting switches, sockets, fan regulators with 3mm thick plastic laminated sheet cover of suitable size, connecting earth for light/fan/bell point including cutting chases in walls and making good to disturbed surface complete all as specified and directed . (Note : Switch/bell push/fan regulator shall be measured and paid separately)
Supply and fixing of switch socket outlet combination, 2 in 1, 5 pin 5 and 15 Amp, piano flush type, 240 volts, complete all as specified and directed.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m deep in any type of soil for laying of underground cable, foundation of poles & stays etc., and getting out, complete all as specified and as directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specified.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified.
Material and Labour for dry fine sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm thick after laying, stretching and testing the cable all as direted. Note: Punned thickness shall be measured
Material and labour for brick sub class 'B' laid dry in trenches over the cable adjoining each other widthwise for cable protection complete all as specified and as directed.
Laying only brick sub class 'B' laid dry in trenches over the cable adjoining each other widthwise for cable protection complete all as specified and as directed.
Supply, laying, connecting and testing XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 10 Sqmm 2 core and making end termination with aluminium lugs and with supporting nuts/bolts laid in trenches or passing through pipes/ducts or fixed to walls/poles including taking out unserviceable LT cable of any size/type, complete all as specified. Note: Earth work, brick protection and sand cushioning shall be measured and paid for separately.
All as above mentioned in item No 17 here in above but Size 16 sqmm 4 core.
All as above mentioned in item No 17 here in above but Size 25 sqmm 4 core.
All as above mentioned in item No 17 here in above but Size 35 sqmm 3.5 core.
All as above mentioned in item No 17 here in above but Size 50 sqmm 3.5 core.
Supply, fixing and testing of Bus bar Panel, Size:0.8x0.4x0.4 Mtr, Kisok outdoor type, CPRI type tested, LT 440 Volts, 50 Hz , 3 Phase 4 wire supply , floor mounted factory fabricated weather and vermin proof protection class IP 54 made out of 1.4 mm thick MS Sheet CRCA on angle iron 30X30X4mm frame of size suitable to incorporate following accessories with front opening doors, locking arrangement powder coated internally and externally, shall have channel base of appropriate size and mounted on PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 type C-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed by the Engr -in - charge including earth work complete comprising of Bus bar chamber comprising 4 Nos Aluminium strip bus bars PVC insulated made of aluminium strip of size suitable for 200A current. PVC sheathed with colour coding including taking out old busbar panel, all as specified and directed.
Supply and fixing in replacement MCB 6-32 Amps SP 'C' series 240 V, 50 Hz, breaking capacity 10 KA suitable for lighting and other domestic loads complete all as specified and directed.
Supply and fixing in replacement MCB 40 Amps SP 'C' series 240 V, 50 Hz, breaking capacity 10 KA suitable for lighting and other domestic loads complete all as specified and directed.
Supply and fixing in replacement MCB 32 Amps SPN 'C' series240 V, 50 Hz, breaking capacity 10 KA, complete all as specified and directed.
Supply and fixing in replacement MCB 40 -63 Amps SPN 'C' series240 V, 50 Hz, breaking capacity 10 KA, complete all as specified and directed.
Supply and fixing in replacement MCB TPN/FP 16 to 32 Amps 415 V 50 Hz, breaking capacity 10 KA 'C' curvecomplete with connection testing and commissioning all as specified and directed.
Supply and fixing in replacement MCB TPN/FP 40 to 100 Amps 415 V 50 Hz, breaking capacity 10 KA 'C' curve complete with connection testing and commissioning all as specified and directed.
Supply and fixing 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire one twin core 16 sq mm solid conductor all as specified and directed.
SINGH CONST CO (BID ID -3079879)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .